{"lab":{"_id":"69ad52a4de79e566650fd33a","accr_number":"1277","country":"CZ","accr_body":"ČIA","address":"Lhotka 219, 560 02 Česká Třebová","categories":["water","environment","microbiology","food"],"city":"Česká Třebová","imported_at":"2026-03-08T10:42:44.590Z","methods_count":76,"name":"ORLICKÁ LABORATOŘ, s.r.o.","parse_status":"parsed","parse_version":5,"pdf_files":["1277_233_2025_CS.pdf","1277_233_2025_EN.pdf"],"scope_summary":"Pobieranie próbek i analizy wód, osadów, odpadów, wyciągów wodnych, osadów dennych, gruntów, kompostów, powietrza, żywności i suplementów diety, w zakresie określonym w załączniku do świadectwa.","search_text":"orlická laboratoř, s.r.o. lhotka 219, 560 02 česká třebová other","status":"active","updated_at":"2026-03-08T14:52:09.957Z","valid_from":"","valid_until":"07-09-2028","website":"www.orlab.cz","parsed_at":"2026-09-28T12:00:00.000Z","map_coord":[49.922029,16.439331],"map_geo":"nominatim-street","certificate_date":"05.05.2026","certificate_no":"236/2026","certificate_replaces":"233/2025 z 19.05.2025","en_official":false,"fields_of_testing":[{"codes":"","pl":"Pobieranie próbek i analizy wód, osadów, odpadów, wyciągów wodnych, osadów dennych, gruntów, kompostów, powietrza, żywności i suplementów diety, w zakresie określonym w załączniku do świadectwa.","en":"Sampling and analysis of water, sludge, waste, aqueous leachates, sediments, soils, composts, air, food and food supplements to the extent as specified in the appendix to this Certificate.","zh":"水、污泥、废物、水浸出液、沉积物、土、堆肥、空气、食品和膳食补充剂的采样和分析，范围见本证书附件。","cs":"Vzorkování a analýza vod, kalů, odpadů, vodných výluhů, sedimentů, zemin, kompostů, ovzduší, potravin a potravinových doplňků vymezené přílohou tohoto osvědčení."}],"flexible_scope":false,"flexible_scope_url":null,"has_en":true,"has_zh":true,"lab_division":"ORLICKÁ LABORATOŘ","lab_division_cs":"ORLICKÁ LABORATOŘ","lab_division_en":"ORLICKÁ LABORATOŘ","lab_division_zh":"ORLICKÁ LABORATOŘ实验室","parse_date":"2026-09-28T12:00:00.000Z","parse_source":"reczna-analiza-labcoda-3","scope_legend":[{"abbr":"TNV","pl":"branżowa norma techniczna gospodarki wodnej","en":"industry technical standard of water management","zh":"水务行业技术标准","cs":"odvětvová technická norma vodního hospodářství"},{"abbr":"MZ","pl":"Ministerstwo Zdrowia","en":"Ministry of Health","zh":"卫生部","cs":"ministerstvo zdravotnictví"},{"abbr":"MŽP","pl":"Ministerstwo Środowiska","en":"Ministry of the Environment","zh":"环境部","cs":"ministerstvo životního prostředí"},{"abbr":"HPLC","pl":"wysokosprawna chromatografia cieczowa","en":"high-performance liquid chromatography","zh":"高效液相色谱","cs":"vysokoúčinná kapalinová chromatografie"},{"abbr":"GC/MS","pl":"chromatografia gazowa z detekcją mas","en":"gas chromatography with mass detection","zh":"气相色谱–质谱检测","cs":"plynová chromatografie s hmotnostní detekcí"},{"abbr":"IC","pl":"chromatografia jonowa","en":"ion chromatography","zh":"离子色谱","cs":"iontová chromatografie"},{"abbr":"ICP/MS","pl":"spektrometria mas z plazmą sprzężoną indukcyjnie","en":"inductively coupled plasma mass spectrometry","zh":"电感耦合等离子体质谱","cs":"hmotnostní spektrometrie s indukčně vázaným plazmatem"},{"abbr":"FID","pl":"detektor płomieniowo-jonizacyjny","en":"flame ionisation detector","zh":"火焰离子化检测器","cs":"plamenový ionizační detektor"},{"abbr":"DAD","pl":"detektor z matrycą fotodiodową","en":"diode array detector","zh":"二极管阵列检测器","cs":"detektor fotodiodového pole"},{"abbr":"FluD","pl":"detektor fluorescencyjny","en":"fluorescence detector","zh":"荧光检测器","cs":"fluorescenční detektor"},{"abbr":"AHEM","pl":"Acta Hygienica, Epidemiologica et Microbiologica","en":"Acta Hygienica, Epidemiologica et Microbiologica","zh":"Acta Hygienica, Epidemiologica et Microbiologica（卫生、流行病学和微生物学学报）","cs":"Acta Hygienica, Epidemiologica et Microbiologica"},{"abbr":"PAU","pl":"wielopierścieniowe węglowodory aromatyczne","en":"polycyclic aromatic hydrocarbons","zh":"多环芳烃","cs":"polycyklické aromatické uhlovodíky"},{"abbr":"BTEX","pl":"benzen, toluen, etylobenzen, ksyleny","en":"benzene, toluene, ethylbenzene, xylenes","zh":"苯、甲苯、乙苯、二甲苯","cs":"benzen, toluen, ethylbenzen, xyleny"},{"abbr":"THM","pl":"trihalometany","en":"trihalomethanes","zh":"三卤甲烷","cs":"trihalomethany"},{"abbr":"TOL","pl":"lotne związki organiczne","en":"volatile organic compounds","zh":"挥发性有机物","cs":"těkavé organické látky"},{"abbr":"CU","pl":"węglowodory chlorowane","en":"chlorinated hydrocarbons","zh":"氯代烃","cs":"chlorované uhlovodíky"}],"scope_notes":[{"pl":"Laboratorium wydaje opinie i interpretacje wyników badań.","en":"The laboratory provides opinions and interpretations of the test results.","zh":"实验室提供检测结果的意见和解释。","cs":"Laboratoř poskytuje stanoviska a interpretace výsledků zkoušek."}],"source_lang":"cs","source_pdf_sha256":"dadee369b59d1a5515d14dcd2d7f535729bd1629423508b4e63f74232d9bf3e6","source_pdf_url":"https://www.cai.cz/OA/pdf/236_2026_CS.pdf","source_pdf_url_en":null},"methods":[{"_id":"cbc2b5e73a7e2d8079f455cf","lab_id":"69ad52a4de79e566650fd33a","country":"CZ","accr_number":"1277","accr_body":"ČIA","row_label":"1","test_object":"Wody: przeznaczone do spożycia, butelkowane, surowe, uzdatnione, ciepłe, podziemne, powierzchniowe, w kąpieliskach i do celów leczniczych","test_object_en":"Drinking, bottled, raw, treated, hot, ground, surface, bathing and therapeutic water","test_object_zh":"饮用水、瓶装水、原水、成品水、热水、地下水、地表水、游泳/浴用和医疗用水","test_object_cs":"Vody pitné, balené, surové, vyrobené, teplé, podzemní, povrchové, ke koupání a léčebným účelům","methodology":"Oznaczanie liczby termotolerancyjnych bakterii z grupy coli i Escherichia coli metodą filtrów membranowych (hodowlana)","methodology_en":"Enumeration of thermotolerant coliform bacteria and Escherichia coli by membrane filtration (culture)","methodology_zh":"耐热大肠菌群和大肠埃希氏菌计数（滤膜法，培养法）","methodology_cs":"Stanovení počtu termotolerantních koliformních bakterií a Escherichia coli metodou membránových filtrů kultivačně","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie liczby termotolerancyjnych bakterii z grupy coli i Escherichia coli metodą filtrów membranowych (hodowlana)","reference":"ZP 002 (ČSN 75 7835)","norm_bases":["ZP 002","ČSN 75 7835"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody: przeznaczone do spożycia, butelkowane, surowe, uzdatnione, ciepłe, podziemne, powierzchniowe, w kąpieliskach i do celów leczniczych Oznaczanie liczby termotolerancyjnych bakterii z grupy coli i Escherichia coli metodą filtrów membranowych (hodowlana) Vody pitné, balené, surové, vyrobené, teplé, podzemní, povrchové, ke koupání a léčebným účelům Stanovení počtu termotolerantních koliformních bakterií a Escherichia coli metodou membránových filtrů kultivačně ZP 002 (ČSN 75 7835) Wody: przeznaczone do spozycia, butelkowane, surowe, uzdatnione, cieple, podziemne, powierzchniowe, w kapieliskach i do celow leczniczych Oznaczanie liczby termotolerancyjnych bakterii z grupy coli i Escherichia coli metoda filtrow membranowych (hodowlana) Vody pitne, balene, surove, vyrobene, teple, podzemni, povrchove, ke koupani a lecebnym ucelum Stanoveni poctu termotolerantnich koliformnich bakterii a Escherichia coli metodou membranovych filtru kultivacne ZP 002 (CSN 75 7835)","search_en":"Drinking, bottled, raw, treated, hot, ground, surface, bathing and therapeutic water Enumeration of thermotolerant coliform bacteria and Escherichia coli by membrane filtration (culture) ZP 002 (ČSN 75 7835)","search_zh":"饮用水、瓶装水、原水、成品水、热水、地下水、地表水、游泳/浴用和医疗用水 耐热大肠菌群和大肠埃希氏菌计数（滤膜法，培养法） ZP 002 (ČSN 75 7835)","categories":["microbiology","water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":0,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"62013d3062cac33ac4b513be","lab_id":"69ad52a4de79e566650fd33a","country":"CZ","accr_number":"1277","accr_body":"ČIA","row_label":"2","test_object":"Wody: przeznaczone do spożycia, butelkowane, surowe, uzdatnione, ciepłe, podziemne, powierzchniowe, w kąpieliskach i do celów leczniczych","test_object_en":"Drinking, bottled, raw, treated, hot, ground, surface, bathing and therapeutic water","test_object_zh":"饮用水、瓶装水、原水、成品水、热水、地下水、地表水、游泳/浴用和医疗用水","test_object_cs":"Vody pitné, balené, surové, vyrobené, teplé, podzemní, povrchové, ke koupání a léčebným účelům","methodology":"Oznaczanie liczby enterokoków jelitowych metodą filtrów membranowych (hodowlana)","methodology_en":"Enumeration of intestinal enterococci by membrane filtration (culture)","methodology_zh":"肠道肠球菌计数（滤膜法，培养法）","methodology_cs":"Stanovení počtu intestinálních enterokoků metodou membránových filtrů kultivačně","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie liczby enterokoków jelitowych metodą filtrów membranowych (hodowlana)","reference":"ZP 003 (ČSN EN ISO 7899-2)","norm_bases":["ZP 003","ČSN EN ISO 7899-2"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody: przeznaczone do spożycia, butelkowane, surowe, uzdatnione, ciepłe, podziemne, powierzchniowe, w kąpieliskach i do celów leczniczych Oznaczanie liczby enterokoków jelitowych metodą filtrów membranowych (hodowlana) Vody pitné, balené, surové, vyrobené, teplé, podzemní, povrchové, ke koupání a léčebným účelům Stanovení počtu intestinálních enterokoků metodou membránových filtrů kultivačně ZP 003 (ČSN EN ISO 7899-2) Wody: przeznaczone do spozycia, butelkowane, surowe, uzdatnione, cieple, podziemne, powierzchniowe, w kapieliskach i do celow leczniczych Oznaczanie liczby enterokokow jelitowych metoda filtrow membranowych (hodowlana) Vody pitne, balene, surove, vyrobene, teple, podzemni, povrchove, ke koupani a lecebnym ucelum Stanoveni poctu intestinalnich enterokoku metodou membranovych filtru kultivacne ZP 003 (CSN EN ISO 7899-2)","search_en":"Drinking, bottled, raw, treated, hot, ground, surface, bathing and therapeutic water Enumeration of intestinal enterococci by membrane filtration (culture) ZP 003 (ČSN EN ISO 7899-2)","search_zh":"饮用水、瓶装水、原水、成品水、热水、地下水、地表水、游泳/浴用和医疗用水 肠道肠球菌计数（滤膜法，培养法） ZP 003 (ČSN EN ISO 7899-2)","categories":["microbiology","water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":1,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"7180e374d0149e4fe4d6ad87","lab_id":"69ad52a4de79e566650fd33a","country":"CZ","accr_number":"1277","accr_body":"ČIA","row_label":"3","test_object":"Wody: przeznaczone do spożycia, butelkowane, surowe, uzdatnione, ciepłe, podziemne, powierzchniowe, w kąpieliskach i do celów leczniczych, technologiczne i przemysłowe","test_object_en":"Drinking, bottled, raw, treated, hot, ground, surface, bathing and therapeutic, process and industrial water","test_object_zh":"饮用水、瓶装水、原水、成品水、热水、地下水、地表水、游泳/浴用和医疗用水、工艺和工业用水","test_object_cs":"Vody pitné, balené, surové, vyrobené, teplé, podzemní, povrchové, ke koupání a léčebným účelům, technologické a průmyslové","methodology":"Oznaczanie liczby mikroorganizmów zdolnych do wzrostu przez posiew do podłoża odżywczego (hodowlana) a) w 22 °C b) w 36 °C","methodology_en":"Enumeration of culturable micro-organisms by inoculation in a nutrient medium (culture) a) at 22 °C b) at 36 °C","methodology_zh":"营养培养基接种法可培养微生物计数（培养法）a) 22 °C b) 36 °C","methodology_cs":"Stanovení počtu kultivovatelných mikroorganismů očkováním do živného média kultivačně a) při teplotě 22 °C b) při teplotě 36 °C","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie liczby mikroorganizmów zdolnych do wzrostu przez posiew do podłoża odżywczego (hodowlana) a) w 22 °C b) w 36 °C","reference":"ZP 004 (ČSN EN ISO 6222)","norm_bases":["ZP 004","ČSN EN ISO 6222"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody: przeznaczone do spożycia, butelkowane, surowe, uzdatnione, ciepłe, podziemne, powierzchniowe, w kąpieliskach i do celów leczniczych, technologiczne i przemysłowe Oznaczanie liczby mikroorganizmów zdolnych do wzrostu przez posiew do podłoża odżywczego (hodowlana) a) w 22 °C b) w 36 °C Vody pitné, balené, surové, vyrobené, teplé, podzemní, povrchové, ke koupání a léčebným účelům, technologické a průmyslové Stanovení počtu kultivovatelných mikroorganismů očkováním do živného média kultivačně a) při teplotě 22 °C b) při teplotě 36 °C ZP 004 (ČSN EN ISO 6222) Wody: przeznaczone do spozycia, butelkowane, surowe, uzdatnione, cieple, podziemne, powierzchniowe, w kapieliskach i do celow leczniczych, technologiczne i przemyslowe Oznaczanie liczby mikroorganizmow zdolnych do wzrostu przez posiew do podloza odzywczego (hodowlana) a) w 22 °C b) w 36 °C Vody pitne, balene, surove, vyrobene, teple, podzemni, povrchove, ke koupani a lecebnym ucelum, technologicke a prumyslove Stanoveni poctu kultivovatelnych mikroorganismu ockovanim do zivneho media kultivacne a) pri teplote 22 °C b) pri teplote 36 °C ZP 004 (CSN EN ISO 6222)","search_en":"Drinking, bottled, raw, treated, hot, ground, surface, bathing and therapeutic, process and industrial water Enumeration of culturable micro-organisms by inoculation in a nutrient medium (culture) a) at 22 °C b) at 36 °C ZP 004 (ČSN EN ISO 6222)","search_zh":"饮用水、瓶装水、原水、成品水、热水、地下水、地表水、游泳/浴用和医疗用水、工艺和工业用水 营养培养基接种法可培养微生物计数（培养法）a) 22 °C b) 36 °C ZP 004 (ČSN EN ISO 6222)","categories":["microbiology","water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":2,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"04d1383de1cf4a877abc1189","lab_id":"69ad52a4de79e566650fd33a","country":"CZ","accr_number":"1277","accr_body":"ČIA","row_label":"4","test_object":"Wody: przeznaczone do spożycia, butelkowane, surowe, uzdatnione, ciepłe, podziemne, powierzchniowe","test_object_en":"Drinking, bottled, raw, treated, hot, ground, surface water","test_object_zh":"饮用水、瓶装水、原水、成品水、热水、地下水、地表水","test_object_cs":"Vody pitné, balené, surové, vyrobené, teplé, podzemní, povrchové","methodology":"Oznaczanie abiosestonu metodą mikroskopową","methodology_en":"Determination of abioseston by microscopy","methodology_zh":"非生物悬浮物测定（显微镜法）","methodology_cs":"Stanovení abiosestonu mikroskopicky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie abiosestonu metodą mikroskopową","reference":"ZP 005 (ČSN 75 7713)","norm_bases":["ZP 005","ČSN 75 7713"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody: przeznaczone do spożycia, butelkowane, surowe, uzdatnione, ciepłe, podziemne, powierzchniowe Oznaczanie abiosestonu metodą mikroskopową Vody pitné, balené, surové, vyrobené, teplé, podzemní, povrchové Stanovení abiosestonu mikroskopicky ZP 005 (ČSN 75 7713) Wody: przeznaczone do spozycia, butelkowane, surowe, uzdatnione, cieple, podziemne, powierzchniowe Oznaczanie abiosestonu metoda mikroskopowa Vody pitne, balene, surove, vyrobene, teple, podzemni, povrchove Stanoveni abiosestonu mikroskopicky ZP 005 (CSN 75 7713)","search_en":"Drinking, bottled, raw, treated, hot, ground, surface water Determination of abioseston by microscopy ZP 005 (ČSN 75 7713)","search_zh":"饮用水、瓶装水、原水、成品水、热水、地下水、地表水 非生物悬浮物测定（显微镜法） ZP 005 (ČSN 75 7713)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":3,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"91612354e2b8fcc72a7aeaf5","lab_id":"69ad52a4de79e566650fd33a","country":"CZ","accr_number":"1277","accr_body":"ČIA","row_label":"5","test_object":"Wody: przeznaczone do spożycia, butelkowane, surowe, uzdatnione, ciepłe, podziemne, powierzchniowe, w kąpieliskach i do celów leczniczych","test_object_en":"Drinking, bottled, raw, treated, hot, ground, surface, bathing and therapeutic water","test_object_zh":"饮用水、瓶装水、原水、成品水、热水、地下水、地表水、游泳/浴用和医疗用水","test_object_cs":"Vody pitné, balené, surové, vyrobené, teplé, podzemní, povrchové, ke koupání a léčebným účelům","methodology":"Oznaczanie biosestonu metodą mikroskopową","methodology_en":"Determination of bioseston by microscopy","methodology_zh":"生物悬浮物测定（显微镜法）","methodology_cs":"Stanovení biosestonu mikroskopicky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie biosestonu metodą mikroskopową","reference":"ZP 006 (ČSN 75 7712)","norm_bases":["ZP 006","ČSN 75 7712"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody: przeznaczone do spożycia, butelkowane, surowe, uzdatnione, ciepłe, podziemne, powierzchniowe, w kąpieliskach i do celów leczniczych Oznaczanie biosestonu metodą mikroskopową Vody pitné, balené, surové, vyrobené, teplé, podzemní, povrchové, ke koupání a léčebným účelům Stanovení biosestonu mikroskopicky ZP 006 (ČSN 75 7712) Wody: przeznaczone do spozycia, butelkowane, surowe, uzdatnione, cieple, podziemne, powierzchniowe, w kapieliskach i do celow leczniczych Oznaczanie biosestonu metoda mikroskopowa Vody pitne, balene, surove, vyrobene, teple, podzemni, povrchove, ke koupani a lecebnym ucelum Stanoveni biosestonu mikroskopicky ZP 006 (CSN 75 7712)","search_en":"Drinking, bottled, raw, treated, hot, ground, surface, bathing and therapeutic water Determination of bioseston by microscopy ZP 006 (ČSN 75 7712)","search_zh":"饮用水、瓶装水、原水、成品水、热水、地下水、地表水、游泳/浴用和医疗用水 生物悬浮物测定（显微镜法） ZP 006 (ČSN 75 7712)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":4,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"7a6da4964ae8c4a2676b6fa7","lab_id":"69ad52a4de79e566650fd33a","country":"CZ","accr_number":"1277","accr_body":"ČIA","row_label":"6","test_object":"Wody: przeznaczone do spożycia, butelkowane, surowe, uzdatnione, ciepłe, podziemne, powierzchniowe, w kąpieliskach i do celów leczniczych, technologiczne i przemysłowe","test_object_en":"Drinking, bottled, raw, treated, hot, ground, surface, bathing and therapeutic, process and industrial water","test_object_zh":"饮用水、瓶装水、原水、成品水、热水、地下水、地表水、游泳/浴用和医疗用水、工艺和工业用水","test_object_cs":"Vody pitné, balené, surové, vyrobené, teplé, podzemní, povrchové, ke koupání a léčebným účelům, technologické a průmyslové","methodology":"Oznaczanie liczby Escherichia coli i bakterii z grupy coli metodą filtrów membranowych na agarze chromogennym (hodowlana)","methodology_en":"Enumeration of Escherichia coli and coliform bacteria by membrane filtration on chromogenic agar (culture)","methodology_zh":"显色琼脂滤膜法大肠埃希氏菌和大肠菌群计数（培养法）","methodology_cs":"Stanovení počtu Escherichia coli a koliformních bakterií metodou membránových filtrů na chromogenním agaru kultivačně","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie liczby Escherichia coli i bakterii z grupy coli metodą filtrów membranowych na agarze chromogennym (hodowlana)","reference":"ZP 007 (ČSN EN ISO 9308-1)","norm_bases":["ZP 007","ČSN EN ISO 9308-1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody: przeznaczone do spożycia, butelkowane, surowe, uzdatnione, ciepłe, podziemne, powierzchniowe, w kąpieliskach i do celów leczniczych, technologiczne i przemysłowe Oznaczanie liczby Escherichia coli i bakterii z grupy coli metodą filtrów membranowych na agarze chromogennym (hodowlana) Vody pitné, balené, surové, vyrobené, teplé, podzemní, povrchové, ke koupání a léčebným účelům, technologické a průmyslové Stanovení počtu Escherichia coli a koliformních bakterií metodou membránových filtrů na chromogenním agaru kultivačně ZP 007 (ČSN EN ISO 9308-1) Wody: przeznaczone do spozycia, butelkowane, surowe, uzdatnione, cieple, podziemne, powierzchniowe, w kapieliskach i do celow leczniczych, technologiczne i przemyslowe Oznaczanie liczby Escherichia coli i bakterii z grupy coli metoda filtrow membranowych na agarze chromogennym (hodowlana) Vody pitne, balene, surove, vyrobene, teple, podzemni, povrchove, ke koupani a lecebnym ucelum, technologicke a prumyslove Stanoveni poctu Escherichia coli a koliformnich bakterii metodou membranovych filtru na chromogennim agaru kultivacne ZP 007 (CSN EN ISO 9308-1)","search_en":"Drinking, bottled, raw, treated, hot, ground, surface, bathing and therapeutic, process and industrial water Enumeration of Escherichia coli and coliform bacteria by membrane filtration on chromogenic agar (culture) ZP 007 (ČSN EN ISO 9308-1)","search_zh":"饮用水、瓶装水、原水、成品水、热水、地下水、地表水、游泳/浴用和医疗用水、工艺和工业用水 显色琼脂滤膜法大肠埃希氏菌和大肠菌群计数（培养法） ZP 007 (ČSN EN ISO 9308-1)","categories":["microbiology","water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":5,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"a531e00db910d505b75ef1db","lab_id":"69ad52a4de79e566650fd33a","country":"CZ","accr_number":"1277","accr_body":"ČIA","row_label":"7","test_object":"Wody: przeznaczone do spożycia, butelkowane, surowe, uzdatnione, ciepłe, podziemne, powierzchniowe, w kąpieliskach i do celów leczniczych","test_object_en":"Drinking, bottled, raw, treated, hot, ground, surface, bathing and therapeutic water","test_object_zh":"饮用水、瓶装水、原水、成品水、热水、地下水、地表水、游泳/浴用和医疗用水","test_object_cs":"Vody pitné, balené, surové, vyrobené, teplé, podzemní, povrchové, ke koupání a léčebným účelům","methodology":"Oznaczanie liczby Pseudomonas aeruginosa metodą filtrów membranowych (hodowlana)","methodology_en":"Enumeration of Pseudomonas aeruginosa by membrane filtration (culture)","methodology_zh":"铜绿假单胞菌计数（滤膜法，培养法）","methodology_cs":"Stanovení počtu Pseudomonas aeruginosa metodou membránových filtrů kultivačně","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie liczby Pseudomonas aeruginosa metodą filtrów membranowych (hodowlana)","reference":"ZP 008 (ČSN EN ISO 16266)","norm_bases":["ZP 008","ČSN EN ISO 16266"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody: przeznaczone do spożycia, butelkowane, surowe, uzdatnione, ciepłe, podziemne, powierzchniowe, w kąpieliskach i do celów leczniczych Oznaczanie liczby Pseudomonas aeruginosa metodą filtrów membranowych (hodowlana) Vody pitné, balené, surové, vyrobené, teplé, podzemní, povrchové, ke koupání a léčebným účelům Stanovení počtu Pseudomonas aeruginosa metodou membránových filtrů kultivačně ZP 008 (ČSN EN ISO 16266) Wody: przeznaczone do spozycia, butelkowane, surowe, uzdatnione, cieple, podziemne, powierzchniowe, w kapieliskach i do celow leczniczych Oznaczanie liczby Pseudomonas aeruginosa metoda filtrow membranowych (hodowlana) Vody pitne, balene, surove, vyrobene, teple, podzemni, povrchove, ke koupani a lecebnym ucelum Stanoveni poctu Pseudomonas aeruginosa metodou membranovych filtru kultivacne ZP 008 (CSN EN ISO 16266)","search_en":"Drinking, bottled, raw, treated, hot, ground, surface, bathing and therapeutic water Enumeration of Pseudomonas aeruginosa by membrane filtration (culture) ZP 008 (ČSN EN ISO 16266)","search_zh":"饮用水、瓶装水、原水、成品水、热水、地下水、地表水、游泳/浴用和医疗用水 铜绿假单胞菌计数（滤膜法，培养法） ZP 008 (ČSN EN ISO 16266)","categories":["microbiology","water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":6,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"727e81a689a84d14bd56b77d","lab_id":"69ad52a4de79e566650fd33a","country":"CZ","accr_number":"1277","accr_body":"ČIA","row_label":"8","test_object":"Wody: przeznaczone do spożycia, butelkowane, surowe, uzdatnione, ciepłe, podziemne, powierzchniowe, w kąpieliskach i do celów leczniczych","test_object_en":"Drinking, bottled, raw, treated, hot, ground, surface, bathing and therapeutic water","test_object_zh":"饮用水、瓶装水、原水、成品水、热水、地下水、地表水、游泳/浴用和医疗用水","test_object_cs":"Vody pitné, balené, surové, vyrobené, teplé, podzemní, povrchové, ke koupání a léčebným účelům","methodology":"Oznaczanie liczby gronkowców koagulazododatnich metodą filtrów membranowych (hodowlana)","methodology_en":"Enumeration of coagulase-positive staphylococci by membrane filtration (culture)","methodology_zh":"凝固酶阳性葡萄球菌计数（滤膜法，培养法）","methodology_cs":"Stanovení počtu koaguláza pozitivních stafylokoků metodou membránových filtrů kultivačně","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie liczby gronkowców koagulazododatnich metodą filtrów membranowych (hodowlana)","reference":"ZP 009 (ČSN EN ISO 6888-1)","norm_bases":["ZP 009","ČSN EN ISO 6888-1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody: przeznaczone do spożycia, butelkowane, surowe, uzdatnione, ciepłe, podziemne, powierzchniowe, w kąpieliskach i do celów leczniczych Oznaczanie liczby gronkowców koagulazododatnich metodą filtrów membranowych (hodowlana) Vody pitné, balené, surové, vyrobené, teplé, podzemní, povrchové, ke koupání a léčebným účelům Stanovení počtu koaguláza pozitivních stafylokoků metodou membránových filtrů kultivačně ZP 009 (ČSN EN ISO 6888-1) Wody: przeznaczone do spozycia, butelkowane, surowe, uzdatnione, cieple, podziemne, powierzchniowe, w kapieliskach i do celow leczniczych Oznaczanie liczby gronkowcow koagulazododatnich metoda filtrow membranowych (hodowlana) Vody pitne, balene, surove, vyrobene, teple, podzemni, povrchove, ke koupani a lecebnym ucelum Stanoveni poctu koagulaza pozitivnich stafylokoku metodou membranovych filtru kultivacne ZP 009 (CSN EN ISO 6888-1)","search_en":"Drinking, bottled, raw, treated, hot, ground, surface, bathing and therapeutic water Enumeration of coagulase-positive staphylococci by membrane filtration (culture) ZP 009 (ČSN EN ISO 6888-1)","search_zh":"饮用水、瓶装水、原水、成品水、热水、地下水、地表水、游泳/浴用和医疗用水 凝固酶阳性葡萄球菌计数（滤膜法，培养法） ZP 009 (ČSN EN ISO 6888-1)","categories":["microbiology","water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":7,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"69f93cf6c3ed3468e91a6054","lab_id":"69ad52a4de79e566650fd33a","country":"CZ","accr_number":"1277","accr_body":"ČIA","row_label":"9","test_object":"Wody: przeznaczone do spożycia, butelkowane, surowe, uzdatnione, ciepłe, podziemne, powierzchniowe","test_object_en":"Drinking, bottled, raw, treated, hot, ground, surface water","test_object_zh":"饮用水、瓶装水、原水、成品水、热水、地下水、地表水","test_object_cs":"Vody pitné, balené, surové, vyrobené, teplé, podzemní, povrchové","methodology":"Oznaczanie liczby Clostridium perfringens metodą filtrów membranowych (hodowlana)","methodology_en":"Enumeration of Clostridium perfringens by membrane filtration (culture)","methodology_zh":"产气荚膜梭菌计数（滤膜法，培养法）","methodology_cs":"Stanovení počtu Clostridium perfringens metodou membránových filtrů kultivačně","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie liczby Clostridium perfringens metodą filtrów membranowych (hodowlana)","reference":"ZP 010 (ČSN EN ISO 14189)","norm_bases":["ZP 010","ČSN EN ISO 14189"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody: przeznaczone do spożycia, butelkowane, surowe, uzdatnione, ciepłe, podziemne, powierzchniowe Oznaczanie liczby Clostridium perfringens metodą filtrów membranowych (hodowlana) Vody pitné, balené, surové, vyrobené, teplé, podzemní, povrchové Stanovení počtu Clostridium perfringens metodou membránových filtrů kultivačně ZP 010 (ČSN EN ISO 14189) Wody: przeznaczone do spozycia, butelkowane, surowe, uzdatnione, cieple, podziemne, powierzchniowe Oznaczanie liczby Clostridium perfringens metoda filtrow membranowych (hodowlana) Vody pitne, balene, surove, vyrobene, teple, podzemni, povrchove Stanoveni poctu Clostridium perfringens metodou membranovych filtru kultivacne ZP 010 (CSN EN ISO 14189)","search_en":"Drinking, bottled, raw, treated, hot, ground, surface water Enumeration of Clostridium perfringens by membrane filtration (culture) ZP 010 (ČSN EN ISO 14189)","search_zh":"饮用水、瓶装水、原水、成品水、热水、地下水、地表水 产气荚膜梭菌计数（滤膜法，培养法） ZP 010 (ČSN EN ISO 14189)","categories":["microbiology","water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":8,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"5b510ef42d93f13aab75ad1c","lab_id":"69ad52a4de79e566650fd33a","country":"CZ","accr_number":"1277","accr_body":"ČIA","row_label":"10","test_object":"Wody: przeznaczone do spożycia, butelkowane, surowe, uzdatnione, ciepłe, podziemne, powierzchniowe, w kąpieliskach i do celów leczniczych, technologiczne i przemysłowe","test_object_en":"Drinking, bottled, raw, treated, hot, ground, surface, bathing and therapeutic, process and industrial water","test_object_zh":"饮用水、瓶装水、原水、成品水、热水、地下水、地表水、游泳/浴用和医疗用水、工艺和工业用水","test_object_cs":"Vody pitné, balené, surové, vyrobené, teplé, podzemní, povrchové, ke koupání a léčebným účelům, technologické a průmyslové","methodology":"Oznaczanie liczby bakterii z rodzaju Legionella metodą filtrów membranowych (hodowlana)","methodology_en":"Enumeration of Legionella by membrane filtration (culture)","methodology_zh":"军团菌属计数（滤膜法，培养法）","methodology_cs":"Stanovení počtu bakterií rodu Legionella metodou membránových filtrů kultivačně","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie liczby bakterii z rodzaju Legionella metodą filtrów membranowych (hodowlana)","reference":"ZP 011 (ČSN EN ISO 11731)","norm_bases":["ZP 011","ČSN EN ISO 11731"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody: przeznaczone do spożycia, butelkowane, surowe, uzdatnione, ciepłe, podziemne, powierzchniowe, w kąpieliskach i do celów leczniczych, technologiczne i przemysłowe Oznaczanie liczby bakterii z rodzaju Legionella metodą filtrów membranowych (hodowlana) Vody pitné, balené, surové, vyrobené, teplé, podzemní, povrchové, ke koupání a léčebným účelům, technologické a průmyslové Stanovení počtu bakterií rodu Legionella metodou membránových filtrů kultivačně ZP 011 (ČSN EN ISO 11731) Wody: przeznaczone do spozycia, butelkowane, surowe, uzdatnione, cieple, podziemne, powierzchniowe, w kapieliskach i do celow leczniczych, technologiczne i przemyslowe Oznaczanie liczby bakterii z rodzaju Legionella metoda filtrow membranowych (hodowlana) Vody pitne, balene, surove, vyrobene, teple, podzemni, povrchove, ke koupani a lecebnym ucelum, technologicke a prumyslove Stanoveni poctu bakterii rodu Legionella metodou membranovych filtru kultivacne ZP 011 (CSN EN ISO 11731)","search_en":"Drinking, bottled, raw, treated, hot, ground, surface, bathing and therapeutic, process and industrial water Enumeration of Legionella by membrane filtration (culture) ZP 011 (ČSN EN ISO 11731)","search_zh":"饮用水、瓶装水、原水、成品水、热水、地下水、地表水、游泳/浴用和医疗用水、工艺和工业用水 军团菌属计数（滤膜法，培养法） ZP 011 (ČSN EN ISO 11731)","categories":["microbiology","water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":9,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"cefb792b5fcbeed34ecd2b84","lab_id":"69ad52a4de79e566650fd33a","country":"CZ","accr_number":"1277","accr_body":"ČIA","row_label":"11","test_object":"Grunty, gleby, osady, osady denne, komposty, odpady, piaski, ścieki","test_object_en":"Earths, soils, sludge, sediments, composts, waste, sands, waste water","test_object_zh":"土、土壤、污泥、沉积物、堆肥、废物、砂、废水","test_object_cs":"Zeminy, půdy, kaly, sedimenty, komposty, odpady, písky, vody odpadní","methodology":"Wykrywanie bakterii z rodzaju Salmonella po namnożeniu (hodowlana)","methodology_en":"Detection of Salmonella after enrichment (culture)","methodology_zh":"沙门氏菌属增菌检测（培养法）","methodology_cs":"Průkaz bakterií rodu Salmonella pomnožením kultivačně","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wykrywanie bakterii z rodzaju Salmonella po namnożeniu (hodowlana)","reference":"ZP 012 (AHEM č. 1/2008)","norm_bases":["ZP 012","AHEM č. 1/2008"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Grunty, gleby, osady, osady denne, komposty, odpady, piaski, ścieki Wykrywanie bakterii z rodzaju Salmonella po namnożeniu (hodowlana) Zeminy, půdy, kaly, sedimenty, komposty, odpady, písky, vody odpadní Průkaz bakterií rodu Salmonella pomnožením kultivačně ZP 012 (AHEM č. 1/2008) Grunty, gleby, osady, osady denne, komposty, odpady, piaski, scieki Wykrywanie bakterii z rodzaju Salmonella po namnozeniu (hodowlana) Zeminy, pudy, kaly, sedimenty, komposty, odpady, pisky, vody odpadni Prukaz bakterii rodu Salmonella pomnozenim kultivacne ZP 012 (AHEM c. 1/2008)","search_en":"Earths, soils, sludge, sediments, composts, waste, sands, waste water Detection of Salmonella after enrichment (culture) ZP 012 (AHEM č. 1/2008)","search_zh":"土、土壤、污泥、沉积物、堆肥、废物、砂、废水 沙门氏菌属增菌检测（培养法） ZP 012 (AHEM č. 1/2008)","categories":["microbiology","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":10,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"7f5784a61ad6fc01a48b6c16","lab_id":"69ad52a4de79e566650fd33a","country":"CZ","accr_number":"1277","accr_body":"ČIA","row_label":"12","test_object":"Grunty, gleby, osady, osady denne, komposty, odpady, piaski, ścieki","test_object_en":"Earths, soils, sludge, sediments, composts, waste, sands, waste water","test_object_zh":"土、土壤、污泥、沉积物、堆肥、废物、砂、废水","test_object_cs":"Zeminy, půdy, kaly, sedimenty, komposty, odpady, písky, vody odpadní","methodology":"Oznaczanie liczby mikroorganizmów wskaźnikowych metodą posiewu powierzchniowego (hodowlana)","methodology_en":"Enumeration of indicator micro-organisms by the spread plate method (culture)","methodology_zh":"指示微生物计数（涂布平板法，培养法）","methodology_cs":"Stanovení počtu indikátorových mikroorganismů roztěrem kultivačně","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie liczby mikroorganizmów wskaźnikowych metodą posiewu powierzchniowego (hodowlana)","reference":"ZP 013 (AHEM č. 1/2008)","norm_bases":["ZP 013","AHEM č. 1/2008"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Grunty, gleby, osady, osady denne, komposty, odpady, piaski, ścieki Oznaczanie liczby mikroorganizmów wskaźnikowych metodą posiewu powierzchniowego (hodowlana) Zeminy, půdy, kaly, sedimenty, komposty, odpady, písky, vody odpadní Stanovení počtu indikátorových mikroorganismů roztěrem kultivačně ZP 013 (AHEM č. 1/2008) Grunty, gleby, osady, osady denne, komposty, odpady, piaski, scieki Oznaczanie liczby mikroorganizmow wskaznikowych metoda posiewu powierzchniowego (hodowlana) Zeminy, pudy, kaly, sedimenty, komposty, odpady, pisky, vody odpadni Stanoveni poctu indikatorovych mikroorganismu rozterem kultivacne ZP 013 (AHEM c. 1/2008)","search_en":"Earths, soils, sludge, sediments, composts, waste, sands, waste water Enumeration of indicator micro-organisms by the spread plate method (culture) ZP 013 (AHEM č. 1/2008)","search_zh":"土、土壤、污泥、沉积物、堆肥、废物、砂、废水 指示微生物计数（涂布平板法，培养法） ZP 013 (AHEM č. 1/2008)","categories":["microbiology","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":11,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"cf8da7c99aafcbeaa22a6877","lab_id":"69ad52a4de79e566650fd33a","country":"CZ","accr_number":"1277","accr_body":"ČIA","row_label":"13","test_object":"Żywność, suplementy diety","test_object_en":"Food, food supplements","test_object_zh":"食品、膳食补充剂","test_object_cs":"Potraviny, potravinové doplňky","methodology":"Oznaczanie liczby drożdży i pleśni metodą posiewu powierzchniowego (hodowlana)","methodology_en":"Enumeration of yeasts and moulds by the spread plate method (culture)","methodology_zh":"酵母和霉菌计数（涂布平板法，培养法）","methodology_cs":"Stanovení počtu kvasinek a plísní roztěrem kultivačně","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie liczby drożdży i pleśni metodą posiewu powierzchniowego (hodowlana)","reference":"ZP 015 (ČSN ISO 21527-1; ČSN ISO 21527-2)","norm_bases":["ZP 015","ČSN ISO 21527-1","ČSN ISO 21527-2"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Żywność, suplementy diety Oznaczanie liczby drożdży i pleśni metodą posiewu powierzchniowego (hodowlana) Potraviny, potravinové doplňky Stanovení počtu kvasinek a plísní roztěrem kultivačně ZP 015 (ČSN ISO 21527-1; ČSN ISO 21527-2) Zywnosc, suplementy diety Oznaczanie liczby drozdzy i plesni metoda posiewu powierzchniowego (hodowlana) Potraviny, potravinove doplnky Stanoveni poctu kvasinek a plisni rozterem kultivacne ZP 015 (CSN ISO 21527-1; CSN ISO 21527-2)","search_en":"Food, food supplements Enumeration of yeasts and moulds by the spread plate method (culture) ZP 015 (ČSN ISO 21527-1; ČSN ISO 21527-2)","search_zh":"食品、膳食补充剂 酵母和霉菌计数（涂布平板法，培养法） ZP 015 (ČSN ISO 21527-1; ČSN ISO 21527-2)","categories":["microbiology","food"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":12,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"f3093353ea423408970ed31f","lab_id":"69ad52a4de79e566650fd33a","country":"CZ","accr_number":"1277","accr_body":"ČIA","row_label":"14","test_object":"Żywność, suplementy diety","test_object_en":"Food, food supplements","test_object_zh":"食品、膳食补充剂","test_object_cs":"Potraviny, potravinové doplňky","methodology":"Oznaczanie liczby bakterii z grupy coli metodą zalewową lub posiewu powierzchniowego (hodowlana)","methodology_en":"Enumeration of coliforms by the pour plate or spread plate method (culture)","methodology_zh":"大肠菌群计数（倾注或涂布平板法，培养法）","methodology_cs":"Stanovení počtu koliformních bakterií přelivem nebo roztěrem kultivačně","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie liczby bakterii z grupy coli metodą zalewową lub posiewu powierzchniowego (hodowlana)","reference":"ZP 016 (ČSN ISO 4832)","norm_bases":["ZP 016","ČSN ISO 4832"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Żywność, suplementy diety Oznaczanie liczby bakterii z grupy coli metodą zalewową lub posiewu powierzchniowego (hodowlana) Potraviny, potravinové doplňky Stanovení počtu koliformních bakterií přelivem nebo roztěrem kultivačně ZP 016 (ČSN ISO 4832) Zywnosc, suplementy diety Oznaczanie liczby bakterii z grupy coli metoda zalewowa lub posiewu powierzchniowego (hodowlana) Potraviny, potravinove doplnky Stanoveni poctu koliformnich bakterii prelivem nebo rozterem kultivacne ZP 016 (CSN ISO 4832)","search_en":"Food, food supplements Enumeration of coliforms by the pour plate or spread plate method (culture) ZP 016 (ČSN ISO 4832)","search_zh":"食品、膳食补充剂 大肠菌群计数（倾注或涂布平板法，培养法） ZP 016 (ČSN ISO 4832)","categories":["microbiology","food"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":13,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"63d3717e744be9a9f9ab7a97","lab_id":"69ad52a4de79e566650fd33a","country":"CZ","accr_number":"1277","accr_body":"ČIA","row_label":"15","test_object":"Żywność, suplementy diety","test_object_en":"Food, food supplements","test_object_zh":"食品、膳食补充剂","test_object_cs":"Potraviny, potravinové doplňky","methodology":"Oznaczanie liczby β-glukuronidazododatnich Escherichia coli metodą zalewową lub posiewu powierzchniowego na agarze chromogennym (hodowlana)","methodology_en":"Enumeration of β-glucuronidase-positive Escherichia coli by the pour plate or spread plate method on chromogenic agar (culture)","methodology_zh":"显色琼脂倾注或涂布平板法β-葡萄糖醛酸酶阳性大肠埃希氏菌计数（培养法）","methodology_cs":"Stanovení počtu β-glukuronidázopozitivních Escherichia coli přelivem nebo roztěrem na chromogenním agaru kultivačně","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie liczby β-glukuronidazododatnich Escherichia coli metodą zalewową lub posiewu powierzchniowego na agarze chromogennym (hodowlana)","reference":"ZP 017 (ČSN ISO 16649-2)","norm_bases":["ZP 017","ČSN ISO 16649-2"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Żywność, suplementy diety Oznaczanie liczby β-glukuronidazododatnich Escherichia coli metodą zalewową lub posiewu powierzchniowego na agarze chromogennym (hodowlana) Potraviny, potravinové doplňky Stanovení počtu β-glukuronidázopozitivních Escherichia coli přelivem nebo roztěrem na chromogenním agaru kultivačně ZP 017 (ČSN ISO 16649-2) Zywnosc, suplementy diety Oznaczanie liczby β-glukuronidazododatnich Escherichia coli metoda zalewowa lub posiewu powierzchniowego na agarze chromogennym (hodowlana) Potraviny, potravinove doplnky Stanoveni poctu β-glukuronidazopozitivnich Escherichia coli prelivem nebo rozterem na chromogennim agaru kultivacne ZP 017 (CSN ISO 16649-2)","search_en":"Food, food supplements Enumeration of β-glucuronidase-positive Escherichia coli by the pour plate or spread plate method on chromogenic agar (culture) ZP 017 (ČSN ISO 16649-2)","search_zh":"食品、膳食补充剂 显色琼脂倾注或涂布平板法β-葡萄糖醛酸酶阳性大肠埃希氏菌计数（培养法） ZP 017 (ČSN ISO 16649-2)","categories":["microbiology","food"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":14,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"460ce2901a19a85565cabfbc","lab_id":"69ad52a4de79e566650fd33a","country":"CZ","accr_number":"1277","accr_body":"ČIA","row_label":"16","test_object":"Żywność, suplementy diety","test_object_en":"Food, food supplements","test_object_zh":"食品、膳食补充剂","test_object_cs":"Potraviny, potravinové doplňky","methodology":"Wykrywanie bakterii z rodzaju Salmonella po namnożeniu (hodowlana)","methodology_en":"Detection of Salmonella after enrichment (culture)","methodology_zh":"沙门氏菌属增菌检测（培养法）","methodology_cs":"Průkaz bakterií rodu Salmonella pomnožením kultivačně","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Wykrywanie bakterii z rodzaju Salmonella po namnożeniu (hodowlana)","reference":"ZP 018 (ČSN EN ISO 6579-1)","norm_bases":["ZP 018","ČSN EN ISO 6579-1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Żywność, suplementy diety Wykrywanie bakterii z rodzaju Salmonella po namnożeniu (hodowlana) Potraviny, potravinové doplňky Průkaz bakterií rodu Salmonella pomnožením kultivačně ZP 018 (ČSN EN ISO 6579-1) Zywnosc, suplementy diety Wykrywanie bakterii z rodzaju Salmonella po namnozeniu (hodowlana) Potraviny, potravinove doplnky Prukaz bakterii rodu Salmonella pomnozenim kultivacne ZP 018 (CSN EN ISO 6579-1)","search_en":"Food, food supplements Detection of Salmonella after enrichment (culture) ZP 018 (ČSN EN ISO 6579-1)","search_zh":"食品、膳食补充剂 沙门氏菌属增菌检测（培养法） ZP 018 (ČSN EN ISO 6579-1)","categories":["microbiology","food"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":15,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"51e7d9e684cc7db20e947ed8","lab_id":"69ad52a4de79e566650fd33a","country":"CZ","accr_number":"1277","accr_body":"ČIA","row_label":"17","test_object":"Żywność, suplementy diety","test_object_en":"Food, food supplements","test_object_zh":"食品、膳食补充剂","test_object_cs":"Potraviny, potravinové doplňky","methodology":"Oznaczanie ogólnej liczby drobnoustrojów metodą zalewową lub posiewu powierzchniowego (hodowlana)","methodology_en":"Enumeration of total micro-organisms by the pour plate or spread plate method (culture)","methodology_zh":"菌落总数测定（倾注或涂布平板法，培养法）","methodology_cs":"Stanovení celkového počtu mikroorganismů přelivem nebo roztěrem kultivačně","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie ogólnej liczby drobnoustrojów metodą zalewową lub posiewu powierzchniowego (hodowlana)","reference":"ZP 020 (ČSN EN ISO 4833-1; ČSN EN ISO 4833-2)","norm_bases":["ZP 020","ČSN EN ISO 4833-1","ČSN EN ISO 4833-2"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Żywność, suplementy diety Oznaczanie ogólnej liczby drobnoustrojów metodą zalewową lub posiewu powierzchniowego (hodowlana) Potraviny, potravinové doplňky Stanovení celkového počtu mikroorganismů přelivem nebo roztěrem kultivačně ZP 020 (ČSN EN ISO 4833-1; ČSN EN ISO 4833-2) Zywnosc, suplementy diety Oznaczanie ogolnej liczby drobnoustrojow metoda zalewowa lub posiewu powierzchniowego (hodowlana) Potraviny, potravinove doplnky Stanoveni celkoveho poctu mikroorganismu prelivem nebo rozterem kultivacne ZP 020 (CSN EN ISO 4833-1; CSN EN ISO 4833-2)","search_en":"Food, food supplements Enumeration of total micro-organisms by the pour plate or spread plate method (culture) ZP 020 (ČSN EN ISO 4833-1; ČSN EN ISO 4833-2)","search_zh":"食品、膳食补充剂 菌落总数测定（倾注或涂布平板法，培养法） ZP 020 (ČSN EN ISO 4833-1; ČSN EN ISO 4833-2)","categories":["microbiology","food"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":16,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"0eaaa7be7a5a5269b81d8b7c","lab_id":"69ad52a4de79e566650fd33a","country":"CZ","accr_number":"1277","accr_body":"ČIA","row_label":"18","test_object":"Wody: przeznaczone do spożycia, butelkowane, surowe, uzdatnione, ciepłe, podziemne, powierzchniowe, w kąpieliskach i do celów leczniczych, technologiczne i przemysłowe, ścieki, powietrze","test_object_en":"Drinking, bottled, raw, treated, hot, ground, surface, bathing and therapeutic, process and industrial, waste water, air","test_object_zh":"饮用水、瓶装水、原水、成品水、热水、地下水、地表水、游泳/浴用和医疗用水、工艺和工业用水、废水、空气","test_object_cs":"Vody pitné, balené, surové, vyrobené, teplé, podzemní, povrchové, ke koupání a léčebným účelům, technologické a průmyslové, odpadní, vzduch","methodology":"Oznaczanie temperatury","methodology_en":"Determination of temperature","methodology_zh":"温度测定","methodology_cs":"Stanovení teploty","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie temperatury","reference":"ZP 021 (ČSN 75 7342)","norm_bases":["ZP 021","ČSN 75 7342"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody: przeznaczone do spożycia, butelkowane, surowe, uzdatnione, ciepłe, podziemne, powierzchniowe, w kąpieliskach i do celów leczniczych, technologiczne i przemysłowe, ścieki, powietrze Oznaczanie temperatury Vody pitné, balené, surové, vyrobené, teplé, podzemní, povrchové, ke koupání a léčebným účelům, technologické a průmyslové, odpadní, vzduch Stanovení teploty ZP 021 (ČSN 75 7342) Wody: przeznaczone do spozycia, butelkowane, surowe, uzdatnione, cieple, podziemne, powierzchniowe, w kapieliskach i do celow leczniczych, technologiczne i przemyslowe, scieki, powietrze Oznaczanie temperatury Vody pitne, balene, surove, vyrobene, teple, podzemni, povrchove, ke koupani a lecebnym ucelum, technologicke a prumyslove, odpadni, vzduch Stanoveni teploty ZP 021 (CSN 75 7342)","search_en":"Drinking, bottled, raw, treated, hot, ground, surface, bathing and therapeutic, process and industrial, waste water, air Determination of temperature ZP 021 (ČSN 75 7342)","search_zh":"饮用水、瓶装水、原水、成品水、热水、地下水、地表水、游泳/浴用和医疗用水、工艺和工业用水、废水、空气 温度测定 ZP 021 (ČSN 75 7342)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":17,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"a78adeff400d72512a499d07","lab_id":"69ad52a4de79e566650fd33a","country":"CZ","accr_number":"1277","accr_body":"ČIA","row_label":"19","test_object":"Wody: przeznaczone do spożycia, butelkowane, surowe, uzdatnione, ciepłe, podziemne, powierzchniowe, w kąpieliskach i do celów leczniczych, technologiczne i przemysłowe","test_object_en":"Drinking, bottled, raw, treated, hot, ground, surface, bathing and therapeutic, process and industrial water","test_object_zh":"饮用水、瓶装水、原水、成品水、热水、地下水、地表水、游泳/浴用和医疗用水、工艺和工业用水","test_object_cs":"Vody pitné, balené, surové, vyrobené, teplé, podzemní, povrchové, ke koupání a léčebným účelům, technologické a průmyslové","methodology":"Oznaczanie barwy metodą spektrofotometryczną","methodology_en":"Determination of colour by spectrophotometry","methodology_zh":"色度测定（分光光度法）","methodology_cs":"Stanovení barvy spektrofotometricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie barwy metodą spektrofotometryczną","reference":"ZP 022 (ČSN EN ISO 7887)","norm_bases":["ZP 022","ČSN EN ISO 7887"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody: przeznaczone do spożycia, butelkowane, surowe, uzdatnione, ciepłe, podziemne, powierzchniowe, w kąpieliskach i do celów leczniczych, technologiczne i przemysłowe Oznaczanie barwy metodą spektrofotometryczną Vody pitné, balené, surové, vyrobené, teplé, podzemní, povrchové, ke koupání a léčebným účelům, technologické a průmyslové Stanovení barvy spektrofotometricky ZP 022 (ČSN EN ISO 7887) Wody: przeznaczone do spozycia, butelkowane, surowe, uzdatnione, cieple, podziemne, powierzchniowe, w kapieliskach i do celow leczniczych, technologiczne i przemyslowe Oznaczanie barwy metoda spektrofotometryczna Vody pitne, balene, surove, vyrobene, teple, podzemni, povrchove, ke koupani a lecebnym ucelum, technologicke a prumyslove Stanoveni barvy spektrofotometricky ZP 022 (CSN EN ISO 7887)","search_en":"Drinking, bottled, raw, treated, hot, ground, surface, bathing and therapeutic, process and industrial water Determination of colour by spectrophotometry ZP 022 (ČSN EN ISO 7887)","search_zh":"饮用水、瓶装水、原水、成品水、热水、地下水、地表水、游泳/浴用和医疗用水、工艺和工业用水 色度测定（分光光度法） ZP 022 (ČSN EN ISO 7887)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":18,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"e4d65b488965c36e021acc46","lab_id":"69ad52a4de79e566650fd33a","country":"CZ","accr_number":"1277","accr_body":"ČIA","row_label":"20","test_object":"Wody: przeznaczone do spożycia, butelkowane, surowe, uzdatnione, ciepłe, podziemne, powierzchniowe, w kąpieliskach i do celów leczniczych, technologiczne i przemysłowe","test_object_en":"Drinking, bottled, raw, treated, hot, ground, surface, bathing and therapeutic, process and industrial water","test_object_zh":"饮用水、瓶装水、原水、成品水、热水、地下水、地表水、游泳/浴用和医疗用水、工艺和工业用水","test_object_cs":"Vody pitné, balené, surové, vyrobené, teplé, podzemní, povrchové, ke koupání a léčebným účelům, technologické a průmyslové","methodology":"Oznaczanie mętności metodą nefelometryczną","methodology_en":"Determination of turbidity by nephelometry","methodology_zh":"浊度测定（散射比浊法）","methodology_cs":"Stanovení zákalu nefelometricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie mętności metodą nefelometryczną","reference":"ZP 023 (ČSN EN ISO 7027-1)","norm_bases":["ZP 023","ČSN EN ISO 7027-1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody: przeznaczone do spożycia, butelkowane, surowe, uzdatnione, ciepłe, podziemne, powierzchniowe, w kąpieliskach i do celów leczniczych, technologiczne i przemysłowe Oznaczanie mętności metodą nefelometryczną Vody pitné, balené, surové, vyrobené, teplé, podzemní, povrchové, ke koupání a léčebným účelům, technologické a průmyslové Stanovení zákalu nefelometricky ZP 023 (ČSN EN ISO 7027-1) Wody: przeznaczone do spozycia, butelkowane, surowe, uzdatnione, cieple, podziemne, powierzchniowe, w kapieliskach i do celow leczniczych, technologiczne i przemyslowe Oznaczanie metnosci metoda nefelometryczna Vody pitne, balene, surove, vyrobene, teple, podzemni, povrchove, ke koupani a lecebnym ucelum, technologicke a prumyslove Stanoveni zakalu nefelometricky ZP 023 (CSN EN ISO 7027-1)","search_en":"Drinking, bottled, raw, treated, hot, ground, surface, bathing and therapeutic, process and industrial water Determination of turbidity by nephelometry ZP 023 (ČSN EN ISO 7027-1)","search_zh":"饮用水、瓶装水、原水、成品水、热水、地下水、地表水、游泳/浴用和医疗用水、工艺和工业用水 浊度测定（散射比浊法） ZP 023 (ČSN EN ISO 7027-1)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":19,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"d57eee18226a08a35e5ba67f","lab_id":"69ad52a4de79e566650fd33a","country":"CZ","accr_number":"1277","accr_body":"ČIA","row_label":"21","test_object":"Wody: przeznaczone do spożycia, butelkowane, surowe, uzdatnione, ciepłe, podziemne, powierzchniowe, w kąpieliskach i do celów leczniczych","test_object_en":"Drinking, bottled, raw, treated, hot, ground, surface, bathing and therapeutic water","test_object_zh":"饮用水、瓶装水、原水、成品水、热水、地下水、地表水、游泳/浴用和医疗用水","test_object_cs":"Vody pitné, balené, surové, vyrobené, teplé, podzemní, povrchové, ke koupání a léčebným účelům","methodology":"Orientacyjna analiza sensoryczna","methodology_en":"Indicative sensory analysis","methodology_zh":"初步感官分析","methodology_cs":"Orientační senzorická analýza","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Orientacyjna analiza sensoryczna","reference":"ZP 024 (ČSN 75 7340; ČSN EN ISO 7027-2)","norm_bases":["ZP 024","ČSN 75 7340","ČSN EN ISO 7027-2"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":"zapach – wody przeznaczone do spożycia, butelkowane, surowe, uzdatnione, ciepłe, podziemne, powierzchniowe, w kąpieliskach i do celów leczniczych | smak – woda przeznaczona do spożycia | przezroczystość, zakwit wody, zanieczyszczenia naturalne, zanieczyszczenia odpadami – woda z kąpielisk naturalnych","note_en":"odour – drinking, bottled, raw, treated, hot, ground, surface, bathing and therapeutic water | taste – drinking water | transparency, water bloom, natural pollution, pollution by waste – water from natural bathing sites","note_zh":"气味–饮用水、瓶装水、原水、成品水、热水、地下水、地表水、游泳/浴用和医疗用水 | 味道–饮用水 | 透明度、水华、自然污染、废物污染–天然浴场水","note_cs":"pach - vody pitné, balené, surové, vyrobené, teplé, podzemní, povrchové, ke koupání a léčebným účelům | chuť - pitná voda | průhlednost, vodní květ, přírodní znečištění, znečištění odpady - voda z přírodních koupališť","search_text":"Wody: przeznaczone do spożycia, butelkowane, surowe, uzdatnione, ciepłe, podziemne, powierzchniowe, w kąpieliskach i do celów leczniczych Orientacyjna analiza sensoryczna Vody pitné, balené, surové, vyrobené, teplé, podzemní, povrchové, ke koupání a léčebným účelům Orientační senzorická analýza ZP 024 (ČSN 75 7340; ČSN EN ISO 7027-2) Wody: przeznaczone do spozycia, butelkowane, surowe, uzdatnione, cieple, podziemne, powierzchniowe, w kapieliskach i do celow leczniczych Orientacyjna analiza sensoryczna Vody pitne, balene, surove, vyrobene, teple, podzemni, povrchove, ke koupani a lecebnym ucelum Orientacni senzoricka analyza ZP 024 (CSN 75 7340; CSN EN ISO 7027-2)","search_en":"Drinking, bottled, raw, treated, hot, ground, surface, bathing and therapeutic water Indicative sensory analysis ZP 024 (ČSN 75 7340; ČSN EN ISO 7027-2)","search_zh":"饮用水、瓶装水、原水、成品水、热水、地下水、地表水、游泳/浴用和医疗用水 初步感官分析 ZP 024 (ČSN 75 7340; ČSN EN ISO 7027-2)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":20,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"9899af79b4b91a1ab8d94002","lab_id":"69ad52a4de79e566650fd33a","country":"CZ","accr_number":"1277","accr_body":"ČIA","row_label":"22","test_object":"Wody: przeznaczone do spożycia, butelkowane, surowe, uzdatnione, ciepłe, podziemne, powierzchniowe, w kąpieliskach i do celów leczniczych, technologiczne i przemysłowe, ścieki, wyciąg wodny","test_object_en":"Drinking, bottled, raw, treated, hot, ground, surface, bathing and therapeutic, process and industrial, waste water, aqueous leachate","test_object_zh":"饮用水、瓶装水、原水、成品水、热水、地下水、地表水、游泳/浴用和医疗用水、工艺和工业用水、废水、水浸出液","test_object_cs":"Vody pitné, balené, surové, vyrobené, teplé, podzemní, povrchové, ke koupání a léčebným účelům, technologické a průmyslové, odpadní, vodný výluh","methodology":"Oznaczanie pH metodą potencjometryczną","methodology_en":"Determination of pH by potentiometry","methodology_zh":"pH测定（电位法）","methodology_cs":"Stanovení pH potenciometricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie pH metodą potencjometryczną","reference":"ZP 025 (ČSN ISO 10523)","norm_bases":["ZP 025","ČSN ISO 10523"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody: przeznaczone do spożycia, butelkowane, surowe, uzdatnione, ciepłe, podziemne, powierzchniowe, w kąpieliskach i do celów leczniczych, technologiczne i przemysłowe, ścieki, wyciąg wodny Oznaczanie pH metodą potencjometryczną Vody pitné, balené, surové, vyrobené, teplé, podzemní, povrchové, ke koupání a léčebným účelům, technologické a průmyslové, odpadní, vodný výluh Stanovení pH potenciometricky ZP 025 (ČSN ISO 10523) Wody: przeznaczone do spozycia, butelkowane, surowe, uzdatnione, cieple, podziemne, powierzchniowe, w kapieliskach i do celow leczniczych, technologiczne i przemyslowe, scieki, wyciag wodny Oznaczanie pH metoda potencjometryczna Vody pitne, balene, surove, vyrobene, teple, podzemni, povrchove, ke koupani a lecebnym ucelum, technologicke a prumyslove, odpadni, vodny vyluh Stanoveni pH potenciometricky ZP 025 (CSN ISO 10523)","search_en":"Drinking, bottled, raw, treated, hot, ground, surface, bathing and therapeutic, process and industrial, waste water, aqueous leachate Determination of pH by potentiometry ZP 025 (ČSN ISO 10523)","search_zh":"饮用水、瓶装水、原水、成品水、热水、地下水、地表水、游泳/浴用和医疗用水、工艺和工业用水、废水、水浸出液 pH测定（电位法） ZP 025 (ČSN ISO 10523)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":21,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"c275e0e60870e7abc19a1430","lab_id":"69ad52a4de79e566650fd33a","country":"CZ","accr_number":"1277","accr_body":"ČIA","row_label":"23","test_object":"Wody: przeznaczone do spożycia, butelkowane, surowe, uzdatnione, ciepłe, podziemne, powierzchniowe, w kąpieliskach i do celów leczniczych, technologiczne i przemysłowe, ścieki, wyciąg wodny","test_object_en":"Drinking, bottled, raw, treated, hot, ground, surface, bathing and therapeutic, process and industrial, waste water, aqueous leachate","test_object_zh":"饮用水、瓶装水、原水、成品水、热水、地下水、地表水、游泳/浴用和医疗用水、工艺和工业用水、废水、水浸出液","test_object_cs":"Vody pitné, balené, surové, vyrobené, teplé, podzemní, povrchové, ke koupání a léčebným účelům, technologické a průmyslové, odpadní, vodný výluh","methodology":"Oznaczanie przewodności elektrycznej właściwej","methodology_en":"Determination of electrical conductivity","methodology_zh":"电导率测定","methodology_cs":"Stanovení elektrické konduktivity","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie przewodności elektrycznej właściwej","reference":"ZP 026 (ČSN EN 27888)","norm_bases":["ZP 026","ČSN EN 27888"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody: przeznaczone do spożycia, butelkowane, surowe, uzdatnione, ciepłe, podziemne, powierzchniowe, w kąpieliskach i do celów leczniczych, technologiczne i przemysłowe, ścieki, wyciąg wodny Oznaczanie przewodności elektrycznej właściwej Vody pitné, balené, surové, vyrobené, teplé, podzemní, povrchové, ke koupání a léčebným účelům, technologické a průmyslové, odpadní, vodný výluh Stanovení elektrické konduktivity ZP 026 (ČSN EN 27888) Wody: przeznaczone do spozycia, butelkowane, surowe, uzdatnione, cieple, podziemne, powierzchniowe, w kapieliskach i do celow leczniczych, technologiczne i przemyslowe, scieki, wyciag wodny Oznaczanie przewodnosci elektrycznej wlasciwej Vody pitne, balene, surove, vyrobene, teple, podzemni, povrchove, ke koupani a lecebnym ucelum, technologicke a prumyslove, odpadni, vodny vyluh Stanoveni elektricke konduktivity ZP 026 (CSN EN 27888)","search_en":"Drinking, bottled, raw, treated, hot, ground, surface, bathing and therapeutic, process and industrial, waste water, aqueous leachate Determination of electrical conductivity ZP 026 (ČSN EN 27888)","search_zh":"饮用水、瓶装水、原水、成品水、热水、地下水、地表水、游泳/浴用和医疗用水、工艺和工业用水、废水、水浸出液 电导率测定 ZP 026 (ČSN EN 27888)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":22,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"311cff662330b228fe6141c5","lab_id":"69ad52a4de79e566650fd33a","country":"CZ","accr_number":"1277","accr_body":"ČIA","row_label":"24","test_object":"Wody: przeznaczone do spożycia, butelkowane, surowe, uzdatnione, ciepłe, podziemne, powierzchniowe, technologiczne i przemysłowe, ścieki","test_object_en":"Drinking, bottled, raw, treated, hot, ground, surface, process and industrial, waste water","test_object_zh":"饮用水、瓶装水、原水、成品水、热水、地下水、地表水、工艺和工业用水、废水","test_object_cs":"Vody pitné, balené, surové, vyrobené, teplé, podzemní, povrchové, technologické a průmyslové, odpadní","methodology":"Oznaczanie zdolności neutralizacji kwasów (KNK) metodą miareczkową, obliczanie indeksu Langeliera, wodorowęglanów i węglanów, twardości węglanowej i niewęglanowej, CO2 wolnego, związanego i agresywnego, mineralizacji ogólnej","methodology_en":"Determination of acid neutralising capacity (ANC) by titration, calculation of Langelier index, hydrogencarbonates and carbonates, carbonate and non-carbonate hardness, free, bound and aggressive CO2, total mineralisation","methodology_zh":"酸中和能力（KNK）测定（滴定法），计算朗格利尔指数、碳酸氢盐和碳酸盐、碳酸盐和非碳酸盐硬度、游离、化合和侵蚀性CO2、总矿化度","methodology_cs":"Stanovení kyselinové neutralizační kapacity (KNK) titračně, dopočet Langelierova indexu, hydrogenuhličitanů a uhličitanů, uhličitanové a neuhličitanové tvrdosti, CO2 volného, vázaného a agresivního, celkové mineralizace","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zdolności neutralizacji kwasów (KNK) metodą miareczkową, obliczanie indeksu Langeliera, wodorowęglanów i węglanów, twardości węglanowej i niewęglanowej, CO2 wolnego, związanego i agresywnego, mineralizacji ogólnej","reference":"ZP 027 (ČSN EN ISO 9963-1)","norm_bases":["ZP 027","ČSN EN ISO 9963-1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody: przeznaczone do spożycia, butelkowane, surowe, uzdatnione, ciepłe, podziemne, powierzchniowe, technologiczne i przemysłowe, ścieki Oznaczanie zdolności neutralizacji kwasów (KNK) metodą miareczkową, obliczanie indeksu Langeliera, wodorowęglanów i węglanów, twardości węglanowej i niewęglanowej, CO2 wolnego, związanego i agresywnego, mineralizacji ogólnej Vody pitné, balené, surové, vyrobené, teplé, podzemní, povrchové, technologické a průmyslové, odpadní Stanovení kyselinové neutralizační kapacity (KNK) titračně, dopočet Langelierova indexu, hydrogenuhličitanů a uhličitanů, uhličitanové a neuhličitanové tvrdosti, CO2 volného, vázaného a agresivního, celkové mineralizace ZP 027 (ČSN EN ISO 9963-1) Wody: przeznaczone do spozycia, butelkowane, surowe, uzdatnione, cieple, podziemne, powierzchniowe, technologiczne i przemyslowe, scieki Oznaczanie zdolnosci neutralizacji kwasow (KNK) metoda miareczkowa, obliczanie indeksu Langeliera, wodoroweglanow i weglanow, twardosci weglanowej i nieweglanowej, CO2 wolnego, zwiazanego i agresywnego, mineralizacji ogolnej Vody pitne, balene, surove, vyrobene, teple, podzemni, povrchove, technologicke a prumyslove, odpadni Stanoveni kyselinove neutralizacni kapacity (KNK) titracne, dopocet Langelierova indexu, hydrogenuhlicitanu a uhlicitanu, uhlicitanove a neuhlicitanove tvrdosti, CO2 volneho, vazaneho a agresivniho, celkove mineralizace ZP 027 (CSN EN ISO 9963-1)","search_en":"Drinking, bottled, raw, treated, hot, ground, surface, process and industrial, waste water Determination of acid neutralising capacity (ANC) by titration, calculation of Langelier index, hydrogencarbonates and carbonates, carbonate and non-carbonate hardness, free, bound and aggressive CO2, total mineralisation ZP 027 (ČSN EN ISO 9963-1)","search_zh":"饮用水、瓶装水、原水、成品水、热水、地下水、地表水、工艺和工业用水、废水 酸中和能力（KNK）测定（滴定法），计算朗格利尔指数、碳酸氢盐和碳酸盐、碳酸盐和非碳酸盐硬度、游离、化合和侵蚀性CO2、总矿化度 ZP 027 (ČSN EN ISO 9963-1)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":23,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"d6ca51f9adb6888bfb5318f9","lab_id":"69ad52a4de79e566650fd33a","country":"CZ","accr_number":"1277","accr_body":"ČIA","row_label":"25","test_object":"Wody: przeznaczone do spożycia, butelkowane, surowe, uzdatnione, ciepłe, podziemne, powierzchniowe, technologiczne i przemysłowe, ścieki","test_object_en":"Drinking, bottled, raw, treated, hot, ground, surface, process and industrial, waste water","test_object_zh":"饮用水、瓶装水、原水、成品水、热水、地下水、地表水、工艺和工业用水、废水","test_object_cs":"Vody pitné, balené, surové, vyrobené, teplé, podzemní, povrchové, technologické a průmyslové, odpadní","methodology":"Oznaczanie zdolności neutralizacji zasad (ZNK) metodą miareczkową","methodology_en":"Determination of base neutralising capacity (BNC) by titration","methodology_zh":"碱中和能力测定（滴定法）","methodology_cs":"Stanovení zásadové neutralizační kapacity (ZNK) titračně","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zdolności neutralizacji zasad (ZNK) metodą miareczkową","reference":"ZP 028 (ČSN 75 7372)","norm_bases":["ZP 028","ČSN 75 7372"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody: przeznaczone do spożycia, butelkowane, surowe, uzdatnione, ciepłe, podziemne, powierzchniowe, technologiczne i przemysłowe, ścieki Oznaczanie zdolności neutralizacji zasad (ZNK) metodą miareczkową Vody pitné, balené, surové, vyrobené, teplé, podzemní, povrchové, technologické a průmyslové, odpadní Stanovení zásadové neutralizační kapacity (ZNK) titračně ZP 028 (ČSN 75 7372) Wody: przeznaczone do spozycia, butelkowane, surowe, uzdatnione, cieple, podziemne, powierzchniowe, technologiczne i przemyslowe, scieki Oznaczanie zdolnosci neutralizacji zasad (ZNK) metoda miareczkowa Vody pitne, balene, surove, vyrobene, teple, podzemni, povrchove, technologicke a prumyslove, odpadni Stanoveni zasadove neutralizacni kapacity (ZNK) titracne ZP 028 (CSN 75 7372)","search_en":"Drinking, bottled, raw, treated, hot, ground, surface, process and industrial, waste water Determination of base neutralising capacity (BNC) by titration ZP 028 (ČSN 75 7372)","search_zh":"饮用水、瓶装水、原水、成品水、热水、地下水、地表水、工艺和工业用水、废水 碱中和能力测定（滴定法） ZP 028 (ČSN 75 7372)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":24,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"d7509dbe0e59f386c4dfee8b","lab_id":"69ad52a4de79e566650fd33a","country":"CZ","accr_number":"1277","accr_body":"ČIA","row_label":"26","test_object":"Wody: przeznaczone do spożycia, butelkowane, surowe, uzdatnione, ciepłe, podziemne, powierzchniowe, w kąpieliskach i do celów leczniczych, technologiczne i przemysłowe, ścieki, wyciąg wodny","test_object_en":"Drinking, bottled, raw, treated, hot, ground, surface, bathing and therapeutic, process and industrial, waste water, aqueous leachate","test_object_zh":"饮用水、瓶装水、原水、成品水、热水、地下水、地表水、游泳/浴用和医疗用水、工艺和工业用水、废水、水浸出液","test_object_cs":"Vody pitné, balené, surové, vyrobené, teplé, podzemní, povrchové, ke koupání a léčebným účelům, technologické a průmyslové, odpadní, vodný výluh","methodology":"Oznaczanie substancji rozpuszczonych i rozpuszczonych soli nieorganicznych (RAS) metodą wagową","methodology_en":"Determination of dissolved solids and dissolved inorganic salts (DIS) by gravimetry","methodology_zh":"溶解性固体和溶解性无机盐测定（重量法）","methodology_cs":"Stanovení rozpuštěných látek a rozpuštěných anorganických solí (RAS) gravimetricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie substancji rozpuszczonych i rozpuszczonych soli nieorganicznych (RAS) metodą wagową","reference":"ZP 030 (ČSN 75 7346; ČSN 75 7347; ČSN EN 15216; ČSN 75 7300)","norm_bases":["ZP 030","ČSN 75 7346","ČSN 75 7347","ČSN EN 15216","ČSN 75 7300"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody: przeznaczone do spożycia, butelkowane, surowe, uzdatnione, ciepłe, podziemne, powierzchniowe, w kąpieliskach i do celów leczniczych, technologiczne i przemysłowe, ścieki, wyciąg wodny Oznaczanie substancji rozpuszczonych i rozpuszczonych soli nieorganicznych (RAS) metodą wagową Vody pitné, balené, surové, vyrobené, teplé, podzemní, povrchové, ke koupání a léčebným účelům, technologické a průmyslové, odpadní, vodný výluh Stanovení rozpuštěných látek a rozpuštěných anorganických solí (RAS) gravimetricky ZP 030 (ČSN 75 7346; ČSN 75 7347; ČSN EN 15216; ČSN 75 7300) Wody: przeznaczone do spozycia, butelkowane, surowe, uzdatnione, cieple, podziemne, powierzchniowe, w kapieliskach i do celow leczniczych, technologiczne i przemyslowe, scieki, wyciag wodny Oznaczanie substancji rozpuszczonych i rozpuszczonych soli nieorganicznych (RAS) metoda wagowa Vody pitne, balene, surove, vyrobene, teple, podzemni, povrchove, ke koupani a lecebnym ucelum, technologicke a prumyslove, odpadni, vodny vyluh Stanoveni rozpustenych latek a rozpustenych anorganickych soli (RAS) gravimetricky ZP 030 (CSN 75 7346; CSN 75 7347; CSN EN 15216; CSN 75 7300)","search_en":"Drinking, bottled, raw, treated, hot, ground, surface, bathing and therapeutic, process and industrial, waste water, aqueous leachate Determination of dissolved solids and dissolved inorganic salts (DIS) by gravimetry ZP 030 (ČSN 75 7346; ČSN 75 7347; ČSN EN 15216; ČSN 75 7300)","search_zh":"饮用水、瓶装水、原水、成品水、热水、地下水、地表水、游泳/浴用和医疗用水、工艺和工业用水、废水、水浸出液 溶解性固体和溶解性无机盐测定（重量法） ZP 030 (ČSN 75 7346; ČSN 75 7347; ČSN EN 15216; ČSN 75 7300)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":25,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"d427a7934d5a05f38b325ae6","lab_id":"69ad52a4de79e566650fd33a","country":"CZ","accr_number":"1277","accr_body":"ČIA","row_label":"27","test_object":"Wody: przeznaczone do spożycia, butelkowane, surowe, uzdatnione, ciepłe, podziemne, powierzchniowe, w kąpieliskach i do celów leczniczych, technologiczne i przemysłowe, ścieki, wyciąg wodny","test_object_en":"Drinking, bottled, raw, treated, hot, ground, surface, bathing and therapeutic, process and industrial, waste water, aqueous leachate","test_object_zh":"饮用水、瓶装水、原水、成品水、热水、地下水、地表水、游泳/浴用和医疗用水、工艺和工业用水、废水、水浸出液","test_object_cs":"Vody pitné, balené, surové, vyrobené, teplé, podzemní, povrchové, ke koupání a léčebným účelům, technologické a průmyslové, odpadní, vodný výluh","methodology":"Oznaczanie zawiesiny ogólnej metodą wagową","methodology_en":"Determination of suspended solids by gravimetry","methodology_zh":"悬浮物测定（重量法）","methodology_cs":"Stanovení nerozpuštěných látek gravimetricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawiesiny ogólnej metodą wagową","reference":"ZP 031 (ČSN EN 872)","norm_bases":["ZP 031","ČSN EN 872"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody: przeznaczone do spożycia, butelkowane, surowe, uzdatnione, ciepłe, podziemne, powierzchniowe, w kąpieliskach i do celów leczniczych, technologiczne i przemysłowe, ścieki, wyciąg wodny Oznaczanie zawiesiny ogólnej metodą wagową Vody pitné, balené, surové, vyrobené, teplé, podzemní, povrchové, ke koupání a léčebným účelům, technologické a průmyslové, odpadní, vodný výluh Stanovení nerozpuštěných látek gravimetricky ZP 031 (ČSN EN 872) Wody: przeznaczone do spozycia, butelkowane, surowe, uzdatnione, cieple, podziemne, powierzchniowe, w kapieliskach i do celow leczniczych, technologiczne i przemyslowe, scieki, wyciag wodny Oznaczanie zawiesiny ogolnej metoda wagowa Vody pitne, balene, surove, vyrobene, teple, podzemni, povrchove, ke koupani a lecebnym ucelum, technologicke a prumyslove, odpadni, vodny vyluh Stanoveni nerozpustenych latek gravimetricky ZP 031 (CSN EN 872)","search_en":"Drinking, bottled, raw, treated, hot, ground, surface, bathing and therapeutic, process and industrial, waste water, aqueous leachate Determination of suspended solids by gravimetry ZP 031 (ČSN EN 872)","search_zh":"饮用水、瓶装水、原水、成品水、热水、地下水、地表水、游泳/浴用和医疗用水、工艺和工业用水、废水、水浸出液 悬浮物测定（重量法） ZP 031 (ČSN EN 872)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":26,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"9b3b4db4eb30eaba8ee57c82","lab_id":"69ad52a4de79e566650fd33a","country":"CZ","accr_number":"1277","accr_body":"ČIA","row_label":"28","test_object":"Wody: podziemne, powierzchniowe, technologiczne i przemysłowe, ścieki, wyciąg wodny","test_object_en":"Ground, surface, process and industrial, waste water, aqueous leachate","test_object_zh":"地下水、地表水、工艺和工业用水、废水、水浸出液","test_object_cs":"Vody podzemní, povrchové, technologické a průmyslové, odpadní, vodný výluh","methodology":"Oznaczanie substancji ekstrahowalnych metodą wagową (ELGR)","methodology_en":"Determination of extractable substances by gravimetry (ELGR)","methodology_zh":"可萃取物测定（重量法，ELGR）","methodology_cs":"Stanovení extrahovatelných látek gravimetricky (ELGR)","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie substancji ekstrahowalnych metodą wagową (ELGR)","reference":"ZP 034 (ČSN 75 7508)","norm_bases":["ZP 034","ČSN 75 7508"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody: podziemne, powierzchniowe, technologiczne i przemysłowe, ścieki, wyciąg wodny Oznaczanie substancji ekstrahowalnych metodą wagową (ELGR) Vody podzemní, povrchové, technologické a průmyslové, odpadní, vodný výluh Stanovení extrahovatelných látek gravimetricky (ELGR) ZP 034 (ČSN 75 7508) Wody: podziemne, powierzchniowe, technologiczne i przemyslowe, scieki, wyciag wodny Oznaczanie substancji ekstrahowalnych metoda wagowa (ELGR) Vody podzemni, povrchove, technologicke a prumyslove, odpadni, vodny vyluh Stanoveni extrahovatelnych latek gravimetricky (ELGR) ZP 034 (CSN 75 7508)","search_en":"Ground, surface, process and industrial, waste water, aqueous leachate Determination of extractable substances by gravimetry (ELGR) ZP 034 (ČSN 75 7508)","search_zh":"地下水、地表水、工艺和工业用水、废水、水浸出液 可萃取物测定（重量法，ELGR） ZP 034 (ČSN 75 7508)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":27,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"b4a9a945b5114eeb355baacc","lab_id":"69ad52a4de79e566650fd33a","country":"CZ","accr_number":"1277","accr_body":"ČIA","row_label":"29","test_object":"Wody: podziemne, powierzchniowe, technologiczne i przemysłowe, ścieki, wyciąg wodny","test_object_en":"Ground, surface, process and industrial, waste water, aqueous leachate","test_object_zh":"地下水、地表水、工艺和工业用水、废水、水浸出液","test_object_cs":"Vody podzemní, povrchové, technologické a průmyslové, odpadní, vodný výluh","methodology":"Oznaczanie azotu amonowego metodą miareczkową po destylacji i obliczanie jonów amonowych","methodology_en":"Determination of ammoniacal nitrogen by titration after distillation and calculation of ammonium","methodology_zh":"蒸馏后滴定法测定氨氮及铵离子计算","methodology_cs":"Stanovení amoniakálního dusíku titračně po destilaci a dopočet amonných iontů","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie azotu amonowego metodą miareczkową po destylacji i obliczanie jonów amonowych","reference":"ZP 036 (ČSN ISO 5664)","norm_bases":["ZP 036","ČSN ISO 5664"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody: podziemne, powierzchniowe, technologiczne i przemysłowe, ścieki, wyciąg wodny Oznaczanie azotu amonowego metodą miareczkową po destylacji i obliczanie jonów amonowych Vody podzemní, povrchové, technologické a průmyslové, odpadní, vodný výluh Stanovení amoniakálního dusíku titračně po destilaci a dopočet amonných iontů ZP 036 (ČSN ISO 5664) Wody: podziemne, powierzchniowe, technologiczne i przemyslowe, scieki, wyciag wodny Oznaczanie azotu amonowego metoda miareczkowa po destylacji i obliczanie jonow amonowych Vody podzemni, povrchove, technologicke a prumyslove, odpadni, vodny vyluh Stanoveni amoniakalniho dusiku titracne po destilaci a dopocet amonnych iontu ZP 036 (CSN ISO 5664)","search_en":"Ground, surface, process and industrial, waste water, aqueous leachate Determination of ammoniacal nitrogen by titration after distillation and calculation of ammonium ZP 036 (ČSN ISO 5664)","search_zh":"地下水、地表水、工艺和工业用水、废水、水浸出液 蒸馏后滴定法测定氨氮及铵离子计算 ZP 036 (ČSN ISO 5664)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":28,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"2335962842931bc74667145a","lab_id":"69ad52a4de79e566650fd33a","country":"CZ","accr_number":"1277","accr_body":"ČIA","row_label":"30","test_object":"Wody: przeznaczone do spożycia, butelkowane, surowe, uzdatnione, ciepłe, podziemne, powierzchniowe, w kąpieliskach i do celów leczniczych, technologiczne i przemysłowe, ścieki, wyciąg wodny","test_object_en":"Drinking, bottled, raw, treated, hot, ground, surface, bathing and therapeutic, process and industrial, waste water, aqueous leachate","test_object_zh":"饮用水、瓶装水、原水、成品水、热水、地下水、地表水、游泳/浴用和医疗用水、工艺和工业用水、废水、水浸出液","test_object_cs":"Vody pitné, balené, surové, vyrobené, teplé, podzemní, povrchové, ke koupání a léčebným účelům, technologické a průmyslové, odpadní, vodný výluh","methodology":"Oznaczanie jonów amonowych metodą spektrofotometryczną i obliczanie azotu amonowego","methodology_en":"Determination of ammonium by spectrophotometry and calculation of ammoniacal nitrogen","methodology_zh":"铵离子测定（分光光度法）及氨氮计算","methodology_cs":"Stanovení amonných iontů spektrofotometricky a dopočet amoniakálního dusíku","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie jonów amonowych metodą spektrofotometryczną i obliczanie azotu amonowego","reference":"ZP 037 (ČSN ISO 7150-1)","norm_bases":["ZP 037","ČSN ISO 7150-1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody: przeznaczone do spożycia, butelkowane, surowe, uzdatnione, ciepłe, podziemne, powierzchniowe, w kąpieliskach i do celów leczniczych, technologiczne i przemysłowe, ścieki, wyciąg wodny Oznaczanie jonów amonowych metodą spektrofotometryczną i obliczanie azotu amonowego Vody pitné, balené, surové, vyrobené, teplé, podzemní, povrchové, ke koupání a léčebným účelům, technologické a průmyslové, odpadní, vodný výluh Stanovení amonných iontů spektrofotometricky a dopočet amoniakálního dusíku ZP 037 (ČSN ISO 7150-1) Wody: przeznaczone do spozycia, butelkowane, surowe, uzdatnione, cieple, podziemne, powierzchniowe, w kapieliskach i do celow leczniczych, technologiczne i przemyslowe, scieki, wyciag wodny Oznaczanie jonow amonowych metoda spektrofotometryczna i obliczanie azotu amonowego Vody pitne, balene, surove, vyrobene, teple, podzemni, povrchove, ke koupani a lecebnym ucelum, technologicke a prumyslove, odpadni, vodny vyluh Stanoveni amonnych iontu spektrofotometricky a dopocet amoniakalniho dusiku ZP 037 (CSN ISO 7150-1)","search_en":"Drinking, bottled, raw, treated, hot, ground, surface, bathing and therapeutic, process and industrial, waste water, aqueous leachate Determination of ammonium by spectrophotometry and calculation of ammoniacal nitrogen ZP 037 (ČSN ISO 7150-1)","search_zh":"饮用水、瓶装水、原水、成品水、热水、地下水、地表水、游泳/浴用和医疗用水、工艺和工业用水、废水、水浸出液 铵离子测定（分光光度法）及氨氮计算 ZP 037 (ČSN ISO 7150-1)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":29,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"536d7635abecad64ba2c5304","lab_id":"69ad52a4de79e566650fd33a","country":"CZ","accr_number":"1277","accr_body":"ČIA","row_label":"31","test_object":"Wody: przeznaczone do spożycia, butelkowane, surowe, uzdatnione, ciepłe, podziemne, powierzchniowe, technologiczne i przemysłowe","test_object_en":"Drinking, bottled, raw, treated, hot, ground, surface, process and industrial water","test_object_zh":"饮用水、瓶装水、原水、成品水、热水、地下水、地表水、工艺和工业用水","test_object_cs":"Vody pitné, balené, surové, vyrobené, teplé, podzemní, povrchové, technologické a průmyslové","methodology":"Oznaczanie chemicznego zapotrzebowania na tlen metodą nadmanganianową (ChZT-Mn) metodą miareczkową","methodology_en":"Determination of chemical oxygen demand with permanganate (COD-Mn) by titration","methodology_zh":"高锰酸盐化学需氧量测定（滴定法）","methodology_cs":"Stanovení chemické spotřeby kyslíku manganistanem (CHSKMn) titračně","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie chemicznego zapotrzebowania na tlen metodą nadmanganianową (ChZT-Mn) metodą miareczkową","reference":"ZP 043 (ČSN EN ISO 8467)","norm_bases":["ZP 043","ČSN EN ISO 8467"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody: przeznaczone do spożycia, butelkowane, surowe, uzdatnione, ciepłe, podziemne, powierzchniowe, technologiczne i przemysłowe Oznaczanie chemicznego zapotrzebowania na tlen metodą nadmanganianową (ChZT-Mn) metodą miareczkową Vody pitné, balené, surové, vyrobené, teplé, podzemní, povrchové, technologické a průmyslové Stanovení chemické spotřeby kyslíku manganistanem (CHSKMn) titračně ZP 043 (ČSN EN ISO 8467) Wody: przeznaczone do spozycia, butelkowane, surowe, uzdatnione, cieple, podziemne, powierzchniowe, technologiczne i przemyslowe Oznaczanie chemicznego zapotrzebowania na tlen metoda nadmanganianowa (ChZT-Mn) metoda miareczkowa Vody pitne, balene, surove, vyrobene, teple, podzemni, povrchove, technologicke a prumyslove Stanoveni chemicke spotreby kysliku manganistanem (CHSKMn) titracne ZP 043 (CSN EN ISO 8467)","search_en":"Drinking, bottled, raw, treated, hot, ground, surface, process and industrial water Determination of chemical oxygen demand with permanganate (COD-Mn) by titration ZP 043 (ČSN EN ISO 8467)","search_zh":"饮用水、瓶装水、原水、成品水、热水、地下水、地表水、工艺和工业用水 高锰酸盐化学需氧量测定（滴定法） ZP 043 (ČSN EN ISO 8467)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":30,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"b612c7cb662f4657b2ea9d08","lab_id":"69ad52a4de79e566650fd33a","country":"CZ","accr_number":"1277","accr_body":"ČIA","row_label":"32","test_object":"Wody: przeznaczone do spożycia, butelkowane, surowe, uzdatnione, ciepłe, podziemne, powierzchniowe, w kąpieliskach i do celów leczniczych, technologiczne i przemysłowe, ścieki, wyciąg wodny","test_object_en":"Drinking, bottled, raw, treated, hot, ground, surface, bathing and therapeutic, process and industrial, waste water, aqueous leachate","test_object_zh":"饮用水、瓶装水、原水、成品水、热水、地下水、地表水、游泳/浴用和医疗用水、工艺和工业用水、废水、水浸出液","test_object_cs":"Vody pitné, balené, surové, vyrobené, teplé, podzemní, povrchové, ke koupání a léčebným účelům, technologické a průmyslové, odpadní, vodný výluh","methodology":"Oznaczanie chemicznego zapotrzebowania na tlen metodą dwuchromianową (ChZT-Cr) metodą spektrofotometryczną","methodology_en":"Determination of chemical oxygen demand with dichromate (COD-Cr) by spectrophotometry","methodology_zh":"重铬酸盐化学需氧量测定（分光光度法）","methodology_cs":"Stanovení chemické spotřeby kyslíku dichromanem (CHSKCr) spektrofotometricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie chemicznego zapotrzebowania na tlen metodą dwuchromianową (ChZT-Cr) metodą spektrofotometryczną","reference":"ZP 044 (ČSN ISO 15705)","norm_bases":["ZP 044","ČSN ISO 15705"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody: przeznaczone do spożycia, butelkowane, surowe, uzdatnione, ciepłe, podziemne, powierzchniowe, w kąpieliskach i do celów leczniczych, technologiczne i przemysłowe, ścieki, wyciąg wodny Oznaczanie chemicznego zapotrzebowania na tlen metodą dwuchromianową (ChZT-Cr) metodą spektrofotometryczną Vody pitné, balené, surové, vyrobené, teplé, podzemní, povrchové, ke koupání a léčebným účelům, technologické a průmyslové, odpadní, vodný výluh Stanovení chemické spotřeby kyslíku dichromanem (CHSKCr) spektrofotometricky ZP 044 (ČSN ISO 15705) Wody: przeznaczone do spozycia, butelkowane, surowe, uzdatnione, cieple, podziemne, powierzchniowe, w kapieliskach i do celow leczniczych, technologiczne i przemyslowe, scieki, wyciag wodny Oznaczanie chemicznego zapotrzebowania na tlen metoda dwuchromianowa (ChZT-Cr) metoda spektrofotometryczna Vody pitne, balene, surove, vyrobene, teple, podzemni, povrchove, ke koupani a lecebnym ucelum, technologicke a prumyslove, odpadni, vodny vyluh Stanoveni chemicke spotreby kysliku dichromanem (CHSKCr) spektrofotometricky ZP 044 (CSN ISO 15705)","search_en":"Drinking, bottled, raw, treated, hot, ground, surface, bathing and therapeutic, process and industrial, waste water, aqueous leachate Determination of chemical oxygen demand with dichromate (COD-Cr) by spectrophotometry ZP 044 (ČSN ISO 15705)","search_zh":"饮用水、瓶装水、原水、成品水、热水、地下水、地表水、游泳/浴用和医疗用水、工艺和工业用水、废水、水浸出液 重铬酸盐化学需氧量测定（分光光度法） ZP 044 (ČSN ISO 15705)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":31,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"7baae612558419932efcf80d","lab_id":"69ad52a4de79e566650fd33a","country":"CZ","accr_number":"1277","accr_body":"ČIA","row_label":"33","test_object":"Wody: przeznaczone do spożycia, butelkowane, surowe, uzdatnione, ciepłe, podziemne, powierzchniowe, w kąpieliskach i do celów leczniczych, ścieki, wyciąg wodny","test_object_en":"Drinking, bottled, raw, treated, hot, ground, surface, bathing and therapeutic, waste water, aqueous leachate","test_object_zh":"饮用水、瓶装水、原水、成品水、热水、地下水、地表水、游泳/浴用和医疗用水、废水、水浸出液","test_object_cs":"Vody pitné, balené, surové, vyrobené, teplé, podzemní, povrchové, ke koupání a léčebným účelům, odpadní, vodný výluh","methodology":"Oznaczanie biochemicznego zapotrzebowania na tlen po n dniach (BZTn) metodą elektrochemiczną z sondą membranową","methodology_en":"Determination of biochemical oxygen demand after n days (BODn) by the electrochemical method with a membrane probe","methodology_zh":"n日生化需氧量测定（膜电极电化学法）","methodology_cs":"Stanovení biochemické spotřeby kyslíku po n dnech (BSKn) elektrochemickou metodou s membránovou sondou","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie biochemicznego zapotrzebowania na tlen po n dniach (BZTn) metodą elektrochemiczną z sondą membranową","reference":"ZP 045 (ČSN EN ISO 5815-1; ČSN EN 1899-2)","norm_bases":["ZP 045","ČSN EN ISO 5815-1","ČSN EN 1899-2"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody: przeznaczone do spożycia, butelkowane, surowe, uzdatnione, ciepłe, podziemne, powierzchniowe, w kąpieliskach i do celów leczniczych, ścieki, wyciąg wodny Oznaczanie biochemicznego zapotrzebowania na tlen po n dniach (BZTn) metodą elektrochemiczną z sondą membranową Vody pitné, balené, surové, vyrobené, teplé, podzemní, povrchové, ke koupání a léčebným účelům, odpadní, vodný výluh Stanovení biochemické spotřeby kyslíku po n dnech (BSKn) elektrochemickou metodou s membránovou sondou ZP 045 (ČSN EN ISO 5815-1; ČSN EN 1899-2) Wody: przeznaczone do spozycia, butelkowane, surowe, uzdatnione, cieple, podziemne, powierzchniowe, w kapieliskach i do celow leczniczych, scieki, wyciag wodny Oznaczanie biochemicznego zapotrzebowania na tlen po n dniach (BZTn) metoda elektrochemiczna z sonda membranowa Vody pitne, balene, surove, vyrobene, teple, podzemni, povrchove, ke koupani a lecebnym ucelum, odpadni, vodny vyluh Stanoveni biochemicke spotreby kysliku po n dnech (BSKn) elektrochemickou metodou s membranovou sondou ZP 045 (CSN EN ISO 5815-1; CSN EN 1899-2)","search_en":"Drinking, bottled, raw, treated, hot, ground, surface, bathing and therapeutic, waste water, aqueous leachate Determination of biochemical oxygen demand after n days (BODn) by the electrochemical method with a membrane probe ZP 045 (ČSN EN ISO 5815-1; ČSN EN 1899-2)","search_zh":"饮用水、瓶装水、原水、成品水、热水、地下水、地表水、游泳/浴用和医疗用水、废水、水浸出液 n日生化需氧量测定（膜电极电化学法） ZP 045 (ČSN EN ISO 5815-1; ČSN EN 1899-2)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":32,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"502838b418fd87485f60917a","lab_id":"69ad52a4de79e566650fd33a","country":"CZ","accr_number":"1277","accr_body":"ČIA","row_label":"34","test_object":"Wody: przeznaczone do spożycia, butelkowane, surowe, uzdatnione, ciepłe, podziemne, powierzchniowe, w kąpieliskach i do celów leczniczych, technologiczne i przemysłowe, ścieki, wyciąg wodny","test_object_en":"Drinking, bottled, raw, treated, hot, ground, surface, bathing and therapeutic, process and industrial, waste water, aqueous leachate","test_object_zh":"饮用水、瓶装水、原水、成品水、热水、地下水、地表水、游泳/浴用和医疗用水、工艺和工业用水、废水、水浸出液","test_object_cs":"Vody pitné, balené, surové, vyrobené, teplé, podzemní, povrchové, ke koupání a léčebným účelům, technologické a průmyslové, odpadní, vodný výluh","methodology":"Oznaczanie tlenu rozpuszczonego metodą elektrochemiczną z sondą membranową i obliczanie tlenu rozpuszczonego w %","methodology_en":"Determination of dissolved oxygen by the electrochemical method with a membrane probe and calculation of dissolved oxygen in %","methodology_zh":"溶解氧测定（膜电极电化学法）及溶解氧饱和度计算","methodology_cs":"Stanovení rozpuštěného kyslíku elektrochemickou metodou s membránovou sondou a dopočet rozpuštěného kyslíku v%","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie tlenu rozpuszczonego metodą elektrochemiczną z sondą membranową i obliczanie tlenu rozpuszczonego w %","reference":"ZP 046 (ČSN EN ISO 5814)","norm_bases":["ZP 046","ČSN EN ISO 5814"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody: przeznaczone do spożycia, butelkowane, surowe, uzdatnione, ciepłe, podziemne, powierzchniowe, w kąpieliskach i do celów leczniczych, technologiczne i przemysłowe, ścieki, wyciąg wodny Oznaczanie tlenu rozpuszczonego metodą elektrochemiczną z sondą membranową i obliczanie tlenu rozpuszczonego w % Vody pitné, balené, surové, vyrobené, teplé, podzemní, povrchové, ke koupání a léčebným účelům, technologické a průmyslové, odpadní, vodný výluh Stanovení rozpuštěného kyslíku elektrochemickou metodou s membránovou sondou a dopočet rozpuštěného kyslíku v% ZP 046 (ČSN EN ISO 5814) Wody: przeznaczone do spozycia, butelkowane, surowe, uzdatnione, cieple, podziemne, powierzchniowe, w kapieliskach i do celow leczniczych, technologiczne i przemyslowe, scieki, wyciag wodny Oznaczanie tlenu rozpuszczonego metoda elektrochemiczna z sonda membranowa i obliczanie tlenu rozpuszczonego w % Vody pitne, balene, surove, vyrobene, teple, podzemni, povrchove, ke koupani a lecebnym ucelum, technologicke a prumyslove, odpadni, vodny vyluh Stanoveni rozpusteneho kysliku elektrochemickou metodou s membranovou sondou a dopocet rozpusteneho kysliku v% ZP 046 (CSN EN ISO 5814)","search_en":"Drinking, bottled, raw, treated, hot, ground, surface, bathing and therapeutic, process and industrial, waste water, aqueous leachate Determination of dissolved oxygen by the electrochemical method with a membrane probe and calculation of dissolved oxygen in % ZP 046 (ČSN EN ISO 5814)","search_zh":"饮用水、瓶装水、原水、成品水、热水、地下水、地表水、游泳/浴用和医疗用水、工艺和工业用水、废水、水浸出液 溶解氧测定（膜电极电化学法）及溶解氧饱和度计算 ZP 046 (ČSN EN ISO 5814)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":33,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"80db1216f981fd94490394fc","lab_id":"69ad52a4de79e566650fd33a","country":"CZ","accr_number":"1277","accr_body":"ČIA","row_label":"35","test_object":"Wody: przeznaczone do spożycia, butelkowane, surowe, uzdatnione, ciepłe, podziemne, powierzchniowe, w kąpieliskach i do celów leczniczych, technologiczne i przemysłowe, ścieki, wyciąg wodny","test_object_en":"Drinking, bottled, raw, treated, hot, ground, surface, bathing and therapeutic, process and industrial, waste water, aqueous leachate","test_object_zh":"饮用水、瓶装水、原水、成品水、热水、地下水、地表水、游泳/浴用和医疗用水、工艺和工业用水、废水、水浸出液","test_object_cs":"Vody pitné, balené, surové, vyrobené, teplé, podzemní, povrchové, ke koupání a léčebným účelům, technologické a průmyslové, odpadní, vodný výluh","methodology":"Oznaczanie tlenu rozpuszczonego z sondą optyczną i obliczanie tlenu rozpuszczonego w %","methodology_en":"Determination of dissolved oxygen with an optical probe and calculation of dissolved oxygen in %","methodology_zh":"溶解氧测定（光学探头）及溶解氧饱和度计算","methodology_cs":"Stanovení rozpuštěného kyslíku elektrochemickou metodou s optickou sondou a dopočet rozpuštěného kyslíku v %","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie tlenu rozpuszczonego z sondą optyczną i obliczanie tlenu rozpuszczonego w %","reference":"ZP 104 (ČSN ISO 17289)","norm_bases":["ZP 104","ČSN ISO 17289"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody: przeznaczone do spożycia, butelkowane, surowe, uzdatnione, ciepłe, podziemne, powierzchniowe, w kąpieliskach i do celów leczniczych, technologiczne i przemysłowe, ścieki, wyciąg wodny Oznaczanie tlenu rozpuszczonego z sondą optyczną i obliczanie tlenu rozpuszczonego w % Vody pitné, balené, surové, vyrobené, teplé, podzemní, povrchové, ke koupání a léčebným účelům, technologické a průmyslové, odpadní, vodný výluh Stanovení rozpuštěného kyslíku elektrochemickou metodou s optickou sondou a dopočet rozpuštěného kyslíku v % ZP 104 (ČSN ISO 17289) Wody: przeznaczone do spozycia, butelkowane, surowe, uzdatnione, cieple, podziemne, powierzchniowe, w kapieliskach i do celow leczniczych, technologiczne i przemyslowe, scieki, wyciag wodny Oznaczanie tlenu rozpuszczonego z sonda optyczna i obliczanie tlenu rozpuszczonego w % Vody pitne, balene, surove, vyrobene, teple, podzemni, povrchove, ke koupani a lecebnym ucelum, technologicke a prumyslove, odpadni, vodny vyluh Stanoveni rozpusteneho kysliku elektrochemickou metodou s optickou sondou a dopocet rozpusteneho kysliku v % ZP 104 (CSN ISO 17289)","search_en":"Drinking, bottled, raw, treated, hot, ground, surface, bathing and therapeutic, process and industrial, waste water, aqueous leachate Determination of dissolved oxygen with an optical probe and calculation of dissolved oxygen in % ZP 104 (ČSN ISO 17289)","search_zh":"饮用水、瓶装水、原水、成品水、热水、地下水、地表水、游泳/浴用和医疗用水、工艺和工业用水、废水、水浸出液 溶解氧测定（光学探头）及溶解氧饱和度计算 ZP 104 (ČSN ISO 17289)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":34,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"249390cf8b25c0cf23369762","lab_id":"69ad52a4de79e566650fd33a","country":"CZ","accr_number":"1277","accr_body":"ČIA","row_label":"36","test_object":"Wody: przeznaczone do spożycia, butelkowane, surowe, uzdatnione, ciepłe, podziemne, powierzchniowe, w kąpieliskach i do celów leczniczych","test_object_en":"Drinking, bottled, raw, treated, hot, ground, surface, bathing and therapeutic water","test_object_zh":"饮用水、瓶装水、原水、成品水、热水、地下水、地表水、游泳/浴用和医疗用水","test_object_cs":"Vody pitné, balené, surové, vyrobené, teplé, podzemní, povrchové, ke koupání a léčebným účelům","methodology":"Oznaczanie substancji humusowych metodą spektrofotometryczną","methodology_en":"Determination of humic substances by spectrophotometry","methodology_zh":"腐殖质测定（分光光度法）","methodology_cs":"Stanovení huminových látek spektrofotometricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie substancji humusowych metodą spektrofotometryczną","reference":"ZP 047 (ČSN 75 7536)","norm_bases":["ZP 047","ČSN 75 7536"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody: przeznaczone do spożycia, butelkowane, surowe, uzdatnione, ciepłe, podziemne, powierzchniowe, w kąpieliskach i do celów leczniczych Oznaczanie substancji humusowych metodą spektrofotometryczną Vody pitné, balené, surové, vyrobené, teplé, podzemní, povrchové, ke koupání a léčebným účelům Stanovení huminových látek spektrofotometricky ZP 047 (ČSN 75 7536) Wody: przeznaczone do spozycia, butelkowane, surowe, uzdatnione, cieple, podziemne, powierzchniowe, w kapieliskach i do celow leczniczych Oznaczanie substancji humusowych metoda spektrofotometryczna Vody pitne, balene, surove, vyrobene, teple, podzemni, povrchove, ke koupani a lecebnym ucelum Stanoveni huminovych latek spektrofotometricky ZP 047 (CSN 75 7536)","search_en":"Drinking, bottled, raw, treated, hot, ground, surface, bathing and therapeutic water Determination of humic substances by spectrophotometry ZP 047 (ČSN 75 7536)","search_zh":"饮用水、瓶装水、原水、成品水、热水、地下水、地表水、游泳/浴用和医疗用水 腐殖质测定（分光光度法） ZP 047 (ČSN 75 7536)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":35,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"e724f5e9d4cf9bdc3dc22693","lab_id":"69ad52a4de79e566650fd33a","country":"CZ","accr_number":"1277","accr_body":"ČIA","row_label":"37","test_object":"Wody: przeznaczone do spożycia, butelkowane, surowe, uzdatnione, ciepłe, podziemne, powierzchniowe, w kąpieliskach i do celów leczniczych, technologiczne i przemysłowe, ścieki, wyciąg wodny","test_object_en":"Drinking, bottled, raw, treated, hot, ground, surface, bathing and therapeutic, process and industrial, waste water, aqueous leachate","test_object_zh":"饮用水、瓶装水、原水、成品水、热水、地下水、地表水、游泳/浴用和医疗用水、工艺和工业用水、废水、水浸出液","test_object_cs":"Vody pitné, balené, surové, vyrobené, teplé, podzemní, povrchové, ke koupání a léčebným účelům, technologické a průmyslové, odpadní, vodný výluh","methodology":"Oznaczanie anionowych substancji powierzchniowo czynnych metodą spektrofotometryczną","methodology_en":"Determination of anionic surfactants by spectrophotometry","methodology_zh":"阴离子表面活性剂测定（分光光度法）","methodology_cs":"Stanovení aniontových tenzidů spektrofotometricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie anionowych substancji powierzchniowo czynnych metodą spektrofotometryczną","reference":"ZP 048 (ČSN EN 903)","norm_bases":["ZP 048","ČSN EN 903"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody: przeznaczone do spożycia, butelkowane, surowe, uzdatnione, ciepłe, podziemne, powierzchniowe, w kąpieliskach i do celów leczniczych, technologiczne i przemysłowe, ścieki, wyciąg wodny Oznaczanie anionowych substancji powierzchniowo czynnych metodą spektrofotometryczną Vody pitné, balené, surové, vyrobené, teplé, podzemní, povrchové, ke koupání a léčebným účelům, technologické a průmyslové, odpadní, vodný výluh Stanovení aniontových tenzidů spektrofotometricky ZP 048 (ČSN EN 903) Wody: przeznaczone do spozycia, butelkowane, surowe, uzdatnione, cieple, podziemne, powierzchniowe, w kapieliskach i do celow leczniczych, technologiczne i przemyslowe, scieki, wyciag wodny Oznaczanie anionowych substancji powierzchniowo czynnych metoda spektrofotometryczna Vody pitne, balene, surove, vyrobene, teple, podzemni, povrchove, ke koupani a lecebnym ucelum, technologicke a prumyslove, odpadni, vodny vyluh Stanoveni aniontovych tenzidu spektrofotometricky ZP 048 (CSN EN 903)","search_en":"Drinking, bottled, raw, treated, hot, ground, surface, bathing and therapeutic, process and industrial, waste water, aqueous leachate Determination of anionic surfactants by spectrophotometry ZP 048 (ČSN EN 903)","search_zh":"饮用水、瓶装水、原水、成品水、热水、地下水、地表水、游泳/浴用和医疗用水、工艺和工业用水、废水、水浸出液 阴离子表面活性剂测定（分光光度法） ZP 048 (ČSN EN 903)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":36,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"203806e6d08afcdf689593fb","lab_id":"69ad52a4de79e566650fd33a","country":"CZ","accr_number":"1277","accr_body":"ČIA","row_label":"38","test_object":"Wody: przeznaczone do spożycia, butelkowane, surowe, uzdatnione, ciepłe, podziemne, powierzchniowe, w kąpieliskach i do celów leczniczych, technologiczne i przemysłowe, ścieki, wyciąg wodny","test_object_en":"Drinking, bottled, raw, treated, hot, ground, surface, bathing and therapeutic, process and industrial, waste water, aqueous leachate","test_object_zh":"饮用水、瓶装水、原水、成品水、热水、地下水、地表水、游泳/浴用和医疗用水、工艺和工业用水、废水、水浸出液","test_object_cs":"Vody pitné, balené, surové, vyrobené, teplé, podzemní, povrchové, ke koupání a léčebným účelům, technologické a průmyslové, odpadní, vodný výluh","methodology":"Oznaczanie fenoli jednowodorotlenowych metodą spektrofotometryczną","methodology_en":"Determination of monohydric phenols by spectrophotometry","methodology_zh":"一元酚测定（分光光度法）","methodology_cs":"Stanovení jednosytných fenolů spektrofotometricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie fenoli jednowodorotlenowych metodą spektrofotometryczną","reference":"ZP 052 (ČSN ISO 6439)","norm_bases":["ZP 052","ČSN ISO 6439"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody: przeznaczone do spożycia, butelkowane, surowe, uzdatnione, ciepłe, podziemne, powierzchniowe, w kąpieliskach i do celów leczniczych, technologiczne i przemysłowe, ścieki, wyciąg wodny Oznaczanie fenoli jednowodorotlenowych metodą spektrofotometryczną Vody pitné, balené, surové, vyrobené, teplé, podzemní, povrchové, ke koupání a léčebným účelům, technologické a průmyslové, odpadní, vodný výluh Stanovení jednosytných fenolů spektrofotometricky ZP 052 (ČSN ISO 6439) Wody: przeznaczone do spozycia, butelkowane, surowe, uzdatnione, cieple, podziemne, powierzchniowe, w kapieliskach i do celow leczniczych, technologiczne i przemyslowe, scieki, wyciag wodny Oznaczanie fenoli jednowodorotlenowych metoda spektrofotometryczna Vody pitne, balene, surove, vyrobene, teple, podzemni, povrchove, ke koupani a lecebnym ucelum, technologicke a prumyslove, odpadni, vodny vyluh Stanoveni jednosytnych fenolu spektrofotometricky ZP 052 (CSN ISO 6439)","search_en":"Drinking, bottled, raw, treated, hot, ground, surface, bathing and therapeutic, process and industrial, waste water, aqueous leachate Determination of monohydric phenols by spectrophotometry ZP 052 (ČSN ISO 6439)","search_zh":"饮用水、瓶装水、原水、成品水、热水、地下水、地表水、游泳/浴用和医疗用水、工艺和工业用水、废水、水浸出液 一元酚测定（分光光度法） ZP 052 (ČSN ISO 6439)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":37,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"ec1dcb746aba8c880a4abf29","lab_id":"69ad52a4de79e566650fd33a","country":"CZ","accr_number":"1277","accr_body":"ČIA","row_label":"39","test_object":"Wody: przeznaczone do spożycia, butelkowane, surowe, uzdatnione, ciepłe, podziemne, powierzchniowe, w kąpieliskach i do celów leczniczych","test_object_en":"Drinking, bottled, raw, treated, hot, ground, surface, bathing and therapeutic water","test_object_zh":"饮用水、瓶装水、原水、成品水、热水、地下水、地表水、游泳/浴用和医疗用水","test_object_cs":"Vody pitné, balené, surové, vyrobené, teplé, podzemní, povrchové, ke koupání a léčebným účelům","methodology":"Oznaczanie absorbancji przy 254 nm metodą spektrofotometryczną","methodology_en":"Determination of absorbance at 254 nm by spectrophotometry","methodology_zh":"254 nm吸光度测定（分光光度法）","methodology_cs":"Stanovení absorbance při 254 nm spektrofotometricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie absorbancji przy 254 nm metodą spektrofotometryczną","reference":"ZP 053 (ČSN 75 7360)","norm_bases":["ZP 053","ČSN 75 7360"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody: przeznaczone do spożycia, butelkowane, surowe, uzdatnione, ciepłe, podziemne, powierzchniowe, w kąpieliskach i do celów leczniczych Oznaczanie absorbancji przy 254 nm metodą spektrofotometryczną Vody pitné, balené, surové, vyrobené, teplé, podzemní, povrchové, ke koupání a léčebným účelům Stanovení absorbance při 254 nm spektrofotometricky ZP 053 (ČSN 75 7360) Wody: przeznaczone do spozycia, butelkowane, surowe, uzdatnione, cieple, podziemne, powierzchniowe, w kapieliskach i do celow leczniczych Oznaczanie absorbancji przy 254 nm metoda spektrofotometryczna Vody pitne, balene, surove, vyrobene, teple, podzemni, povrchove, ke koupani a lecebnym ucelum Stanoveni absorbance pri 254 nm spektrofotometricky ZP 053 (CSN 75 7360)","search_en":"Drinking, bottled, raw, treated, hot, ground, surface, bathing and therapeutic water Determination of absorbance at 254 nm by spectrophotometry ZP 053 (ČSN 75 7360)","search_zh":"饮用水、瓶装水、原水、成品水、热水、地下水、地表水、游泳/浴用和医疗用水 254 nm吸光度测定（分光光度法） ZP 053 (ČSN 75 7360)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":38,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"92c93894312c2ce252e30a0f","lab_id":"69ad52a4de79e566650fd33a","country":"CZ","accr_number":"1277","accr_body":"ČIA","row_label":"40","test_object":"Wody: przeznaczone do spożycia, butelkowane, surowe, uzdatnione, ciepłe, podziemne, powierzchniowe, w kąpieliskach i do celów leczniczych, ścieki","test_object_en":"Drinking, bottled, raw, treated, hot, ground, surface, bathing and therapeutic, waste water","test_object_zh":"饮用水、瓶装水、原水、成品水、热水、地下水、地表水、游泳/浴用和医疗用水、废水","test_object_cs":"Vody pitné, balené, surové, vyrobené, teplé, podzemní, povrchové, ke koupání a léčebným účelům, odpadní","methodology":"Oznaczanie chloru ogólnego i wolnego metodą spektrofotometryczną komercyjnym zestawem HACH oraz obliczanie chloru związanego i ditlenku chloru","methodology_en":"Determination of total and free chlorine by spectrophotometry with a HACH commercial kit and calculation of combined chlorine and chlorine dioxide","methodology_zh":"HACH商品试剂盒分光光度法测定总氯和游离氯及化合氯和二氧化氯计算","methodology_cs":"Stanovení celkového a volného chloru spektrofotometricky analytickou komerční soupravou HACH a dopočet vázaného chloru a oxidu chloričitého","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie chloru ogólnego i wolnego metodą spektrofotometryczną komercyjnym zestawem HACH oraz obliczanie chloru związanego i ditlenku chloru","reference":"ZP 055 (ČSN EN ISO 7393-2; návod firmy Hach)","norm_bases":["ZP 055","ČSN EN ISO 7393-2","návod firmy Hach"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody: przeznaczone do spożycia, butelkowane, surowe, uzdatnione, ciepłe, podziemne, powierzchniowe, w kąpieliskach i do celów leczniczych, ścieki Oznaczanie chloru ogólnego i wolnego metodą spektrofotometryczną komercyjnym zestawem HACH oraz obliczanie chloru związanego i ditlenku chloru Vody pitné, balené, surové, vyrobené, teplé, podzemní, povrchové, ke koupání a léčebným účelům, odpadní Stanovení celkového a volného chloru spektrofotometricky analytickou komerční soupravou HACH a dopočet vázaného chloru a oxidu chloričitého ZP 055 (ČSN EN ISO 7393-2; návod firmy Hach) Wody: przeznaczone do spozycia, butelkowane, surowe, uzdatnione, cieple, podziemne, powierzchniowe, w kapieliskach i do celow leczniczych, scieki Oznaczanie chloru ogolnego i wolnego metoda spektrofotometryczna komercyjnym zestawem HACH oraz obliczanie chloru zwiazanego i ditlenku chloru Vody pitne, balene, surove, vyrobene, teple, podzemni, povrchove, ke koupani a lecebnym ucelum, odpadni Stanoveni celkoveho a volneho chloru spektrofotometricky analytickou komercni soupravou HACH a dopocet vazaneho chloru a oxidu chloriciteho ZP 055 (CSN EN ISO 7393-2; navod firmy Hach)","search_en":"Drinking, bottled, raw, treated, hot, ground, surface, bathing and therapeutic, waste water Determination of total and free chlorine by spectrophotometry with a HACH commercial kit and calculation of combined chlorine and chlorine dioxide ZP 055 (ČSN EN ISO 7393-2; návod firmy Hach)","search_zh":"饮用水、瓶装水、原水、成品水、热水、地下水、地表水、游泳/浴用和医疗用水、废水 HACH商品试剂盒分光光度法测定总氯和游离氯及化合氯和二氧化氯计算 ZP 055 (ČSN EN ISO 7393-2; návod firmy Hach)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":39,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"335eb1122647adc0402d4872","lab_id":"69ad52a4de79e566650fd33a","country":"CZ","accr_number":"1277","accr_body":"ČIA","row_label":"41","test_object":"Wody: przeznaczone do spożycia, butelkowane, surowe, uzdatnione, ciepłe, podziemne, powierzchniowe, w kąpieliskach i do celów leczniczych, technologiczne i przemysłowe, ścieki, wyciąg wodny, roztwory absorpcyjne (emisje, powietrze wewnętrzne i na stanowiskach pracy)","test_object_en":"Drinking, bottled, raw, treated, hot, ground, surface, bathing and therapeutic, process and industrial, waste water, aqueous leachate, absorption solutions (emissions, indoor and workplace air)","test_object_zh":"饮用水、瓶装水、原水、成品水、热水、地下水、地表水、游泳/浴用和医疗用水、工艺和工业用水、废水、水浸出液、吸收液（排放、室内和工作场所空气）","test_object_cs":"Vody pitné, balené, surové, vyrobené, teplé, podzemní, povrchové, ke koupání a léčebným účelům, technologické a průmyslové, odpadní, vodný výluh, absorpční roztoky (emise, vnitřní a pracovní ovzduší)","methodology":"Oznaczanie cyjanków ogólnych metodą spektrofotometryczną","methodology_en":"Determination of total cyanides by spectrophotometry","methodology_zh":"总氰化物测定（分光光度法）","methodology_cs":"Stanovení celkových kyanidů spektrofotometricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie cyjanków ogólnych metodą spektrofotometryczną","reference":"ZP 056 (ČSN 75 7415)","norm_bases":["ZP 056","ČSN 75 7415"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody: przeznaczone do spożycia, butelkowane, surowe, uzdatnione, ciepłe, podziemne, powierzchniowe, w kąpieliskach i do celów leczniczych, technologiczne i przemysłowe, ścieki, wyciąg wodny, roztwory absorpcyjne (emisje, powietrze wewnętrzne i na stanowiskach pracy) Oznaczanie cyjanków ogólnych metodą spektrofotometryczną Vody pitné, balené, surové, vyrobené, teplé, podzemní, povrchové, ke koupání a léčebným účelům, technologické a průmyslové, odpadní, vodný výluh, absorpční roztoky (emise, vnitřní a pracovní ovzduší) Stanovení celkových kyanidů spektrofotometricky ZP 056 (ČSN 75 7415) Wody: przeznaczone do spozycia, butelkowane, surowe, uzdatnione, cieple, podziemne, powierzchniowe, w kapieliskach i do celow leczniczych, technologiczne i przemyslowe, scieki, wyciag wodny, roztwory absorpcyjne (emisje, powietrze wewnetrzne i na stanowiskach pracy) Oznaczanie cyjankow ogolnych metoda spektrofotometryczna Vody pitne, balene, surove, vyrobene, teple, podzemni, povrchove, ke koupani a lecebnym ucelum, technologicke a prumyslove, odpadni, vodny vyluh, absorpcni roztoky (emise, vnitrni a pracovni ovzdusi) Stanoveni celkovych kyanidu spektrofotometricky ZP 056 (CSN 75 7415)","search_en":"Drinking, bottled, raw, treated, hot, ground, surface, bathing and therapeutic, process and industrial, waste water, aqueous leachate, absorption solutions (emissions, indoor and workplace air) Determination of total cyanides by spectrophotometry ZP 056 (ČSN 75 7415)","search_zh":"饮用水、瓶装水、原水、成品水、热水、地下水、地表水、游泳/浴用和医疗用水、工艺和工业用水、废水、水浸出液、吸收液（排放、室内和工作场所空气） 总氰化物测定（分光光度法） ZP 056 (ČSN 75 7415)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":40,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"bfe05952c8e583d1794886b9","lab_id":"69ad52a4de79e566650fd33a","country":"CZ","accr_number":"1277","accr_body":"ČIA","row_label":"42","test_object":"Osady","test_object_en":"Sludge","test_object_zh":"污泥","test_object_cs":"Kaly","methodology":"Oznaczanie substancji ogólnych, nierozpuszczonych i opadających oraz obliczanie indeksu osadu metodą wagową","methodology_en":"Determination of total, undissolved and settleable solids and calculation of the sludge index by gravimetry","methodology_zh":"总固体、不溶物和可沉降物测定及污泥指数计算（重量法）","methodology_cs":"Stanovení veškerých, nerozpuštěných a usaditelných látek a dopočet kalového indexu gravimetricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie substancji ogólnych, nierozpuszczonych i opadających oraz obliczanie indeksu osadu metodą wagową","reference":"ZP 060 (ČSN EN 14702-1; M. Sedláček a kol., Metody rozboru kalů a pevných odpadů, SZN 1978)","norm_bases":["ZP 060","ČSN EN 14702-1","M. Sedláček a kol., Metody rozboru kalů a pevných odpadů, SZN 1978"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Osady Oznaczanie substancji ogólnych, nierozpuszczonych i opadających oraz obliczanie indeksu osadu metodą wagową Kaly Stanovení veškerých, nerozpuštěných a usaditelných látek a dopočet kalového indexu gravimetricky ZP 060 (ČSN EN 14702-1; M. Sedláček a kol., Metody rozboru kalů a pevných odpadů, SZN 1978) Osady Oznaczanie substancji ogolnych, nierozpuszczonych i opadajacych oraz obliczanie indeksu osadu metoda wagowa Kaly Stanoveni veskerych, nerozpustenych a usaditelnych latek a dopocet kaloveho indexu gravimetricky ZP 060 (CSN EN 14702-1; M. Sedlacek a kol., Metody rozboru kalu a pevnych odpadu, SZN 1978)","search_en":"Sludge Determination of total, undissolved and settleable solids and calculation of the sludge index by gravimetry ZP 060 (ČSN EN 14702-1; M. Sedláček a kol., Metody rozboru kalů a pevných odpadů, SZN 1978)","search_zh":"污泥 总固体、不溶物和可沉降物测定及污泥指数计算（重量法） ZP 060 (ČSN EN 14702-1; M. Sedláček a kol., Metody rozboru kalů a pevných odpadů, SZN 1978)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":41,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"410351402348bb12496e8f92","lab_id":"69ad52a4de79e566650fd33a","country":"CZ","accr_number":"1277","accr_body":"ČIA","row_label":"43","test_object":"Grunty, gleby, osady, osady denne, komposty, odpady, piaski","test_object_en":"Earths, soils, sludge, sediments, composts, waste, sands","test_object_zh":"土、土壤、污泥、沉积物、堆肥、废物、砂","test_object_cs":"Zeminy, půdy, kaly, sedimenty, komposty, odpady, písky","methodology":"Oznaczanie suchej masy, wilgotności, substancji palnych i straty prażenia metodą wagową","methodology_en":"Determination of dry matter, moisture, combustible matter and loss on ignition by gravimetry","methodology_zh":"干物质、水分、可燃物和灼烧损失测定（重量法）","methodology_cs":"Stanovení sušiny, vlhkosti, spalitelných látek a ztráty žíháním gravimetricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie suchej masy, wilgotności, substancji palnych i straty prażenia metodą wagową","reference":"ZP 061 (ČSN 46 5735; ČSN EN 15935; ČSN EN 15934)","norm_bases":["ZP 061","ČSN 46 5735","ČSN EN 15935","ČSN EN 15934"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Grunty, gleby, osady, osady denne, komposty, odpady, piaski Oznaczanie suchej masy, wilgotności, substancji palnych i straty prażenia metodą wagową Zeminy, půdy, kaly, sedimenty, komposty, odpady, písky Stanovení sušiny, vlhkosti, spalitelných látek a ztráty žíháním gravimetricky ZP 061 (ČSN 46 5735; ČSN EN 15935; ČSN EN 15934) Grunty, gleby, osady, osady denne, komposty, odpady, piaski Oznaczanie suchej masy, wilgotnosci, substancji palnych i straty prazenia metoda wagowa Zeminy, pudy, kaly, sedimenty, komposty, odpady, pisky Stanoveni susiny, vlhkosti, spalitelnych latek a ztraty zihanim gravimetricky ZP 061 (CSN 46 5735; CSN EN 15935; CSN EN 15934)","search_en":"Earths, soils, sludge, sediments, composts, waste, sands Determination of dry matter, moisture, combustible matter and loss on ignition by gravimetry ZP 061 (ČSN 46 5735; ČSN EN 15935; ČSN EN 15934)","search_zh":"土、土壤、污泥、沉积物、堆肥、废物、砂 干物质、水分、可燃物和灼烧损失测定（重量法） ZP 061 (ČSN 46 5735; ČSN EN 15935; ČSN EN 15934)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":42,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"2c0de5e2c481fee31ee32dc2","lab_id":"69ad52a4de79e566650fd33a","country":"CZ","accr_number":"1277","accr_body":"ČIA","row_label":"44","test_object":"Grunty, gleby, osady, osady denne, komposty, odpady, piaski","test_object_en":"Earths, soils, sludge, sediments, composts, waste, sands","test_object_zh":"土、土壤、污泥、沉积物、堆肥、废物、砂","test_object_cs":"Zeminy, půdy, kaly, sedimenty, komposty, odpady, písky","methodology":"Oznaczanie pH substancji stałych metodą potencjometryczną","methodology_en":"Determination of pH of solids by potentiometry","methodology_zh":"固体pH测定（电位法）","methodology_cs":"Stanovení pH pevných látek potenciometricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie pH substancji stałych metodą potencjometryczną","reference":"ZP 062 (ČSN EN ISO 10390)","norm_bases":["ZP 062","ČSN EN ISO 10390"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Grunty, gleby, osady, osady denne, komposty, odpady, piaski Oznaczanie pH substancji stałych metodą potencjometryczną Zeminy, půdy, kaly, sedimenty, komposty, odpady, písky Stanovení pH pevných látek potenciometricky ZP 062 (ČSN EN ISO 10390) Grunty, gleby, osady, osady denne, komposty, odpady, piaski Oznaczanie pH substancji stalych metoda potencjometryczna Zeminy, pudy, kaly, sedimenty, komposty, odpady, pisky Stanoveni pH pevnych latek potenciometricky ZP 062 (CSN EN ISO 10390)","search_en":"Earths, soils, sludge, sediments, composts, waste, sands Determination of pH of solids by potentiometry ZP 062 (ČSN EN ISO 10390)","search_zh":"土、土壤、污泥、沉积物、堆肥、废物、砂 固体pH测定（电位法） ZP 062 (ČSN EN ISO 10390)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":43,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"dde87addb72c14145224e4e2","lab_id":"69ad52a4de79e566650fd33a","country":"CZ","accr_number":"1277","accr_body":"ČIA","row_label":"45","test_object":"Grunty, gleby, osady, osady denne, komposty, odpady, piaski","test_object_en":"Earths, soils, sludge, sediments, composts, waste, sands","test_object_zh":"土、土壤、污泥、沉积物、堆肥、废物、砂","test_object_cs":"Zeminy, půdy, kaly, sedimenty, komposty, odpady, písky","methodology":"Oznaczanie azotu metodą Kjeldahla","methodology_en":"Determination of Kjeldahl nitrogen","methodology_zh":"凯氏氮测定","methodology_cs":"Stanovení dusíku podle Kjeldahla","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie azotu metodą Kjeldahla","reference":"ZP 063 (ČSN EN 13342)","norm_bases":["ZP 063","ČSN EN 13342"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Grunty, gleby, osady, osady denne, komposty, odpady, piaski Oznaczanie azotu metodą Kjeldahla Zeminy, půdy, kaly, sedimenty, komposty, odpady, písky Stanovení dusíku podle Kjeldahla ZP 063 (ČSN EN 13342) Grunty, gleby, osady, osady denne, komposty, odpady, piaski Oznaczanie azotu metoda Kjeldahla Zeminy, pudy, kaly, sedimenty, komposty, odpady, pisky Stanoveni dusiku podle Kjeldahla ZP 063 (CSN EN 13342)","search_en":"Earths, soils, sludge, sediments, composts, waste, sands Determination of Kjeldahl nitrogen ZP 063 (ČSN EN 13342)","search_zh":"土、土壤、污泥、沉积物、堆肥、废物、砂 凯氏氮测定 ZP 063 (ČSN EN 13342)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":44,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"f0735a30b5209873bb4ffb87","lab_id":"69ad52a4de79e566650fd33a","country":"CZ","accr_number":"1277","accr_body":"ČIA","row_label":"46","test_object":"Wody: przeznaczone do spożycia, butelkowane, surowe, uzdatnione, ciepłe, podziemne, powierzchniowe, technologiczne i przemysłowe, ścieki, wyciąg wodny","test_object_en":"Drinking, bottled, raw, treated, hot, ground, surface, process and industrial, waste water, aqueous leachate","test_object_zh":"饮用水、瓶装水、原水、成品水、热水、地下水、地表水、工艺和工业用水、废水、水浸出液","test_object_cs":"Vody pitné, balené, surové, vyrobené, teplé, podzemní, povrchové, technologické a průmyslové, odpadní, vodný výluh","methodology":"Oznaczanie niejonowych substancji powierzchniowo czynnych metodą spektrofotometryczną","methodology_en":"Determination of non-ionic surfactants by spectrophotometry","methodology_zh":"非离子表面活性剂测定（分光光度法）","methodology_cs":"Stanovení neiontových tenzidů spektrofotometricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie niejonowych substancji powierzchniowo czynnych metodą spektrofotometryczną","reference":"ZP 050 (návod firmy Hach)","norm_bases":["ZP 050","návod firmy Hach"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody: przeznaczone do spożycia, butelkowane, surowe, uzdatnione, ciepłe, podziemne, powierzchniowe, technologiczne i przemysłowe, ścieki, wyciąg wodny Oznaczanie niejonowych substancji powierzchniowo czynnych metodą spektrofotometryczną Vody pitné, balené, surové, vyrobené, teplé, podzemní, povrchové, technologické a průmyslové, odpadní, vodný výluh Stanovení neiontových tenzidů spektrofotometricky ZP 050 (návod firmy Hach) Wody: przeznaczone do spozycia, butelkowane, surowe, uzdatnione, cieple, podziemne, powierzchniowe, technologiczne i przemyslowe, scieki, wyciag wodny Oznaczanie niejonowych substancji powierzchniowo czynnych metoda spektrofotometryczna Vody pitne, balene, surove, vyrobene, teple, podzemni, povrchove, technologicke a prumyslove, odpadni, vodny vyluh Stanoveni neiontovych tenzidu spektrofotometricky ZP 050 (navod firmy Hach)","search_en":"Drinking, bottled, raw, treated, hot, ground, surface, process and industrial, waste water, aqueous leachate Determination of non-ionic surfactants by spectrophotometry ZP 050 (návod firmy Hach)","search_zh":"饮用水、瓶装水、原水、成品水、热水、地下水、地表水、工艺和工业用水、废水、水浸出液 非离子表面活性剂测定（分光光度法） ZP 050 (návod firmy Hach)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":45,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"09c659e0141d4501c0e8089b","lab_id":"69ad52a4de79e566650fd33a","country":"CZ","accr_number":"1277","accr_body":"ČIA","row_label":"47","test_object":"Wody: przeznaczone do spożycia, butelkowane, surowe, uzdatnione, ciepłe, podziemne, powierzchniowe, technologiczne i przemysłowe, ścieki, wyciąg wodny, roztwory absorpcyjne (emisje, powietrze wewnętrzne i na stanowiskach pracy)","test_object_en":"Drinking, bottled, raw, treated, hot, ground, surface, process and industrial, waste water, aqueous leachate, absorption solutions (emissions, indoor and workplace air)","test_object_zh":"饮用水、瓶装水、原水、成品水、热水、地下水、地表水、工艺和工业用水、废水、水浸出液、吸收液（排放、室内和工作场所空气）","test_object_cs":"Vody pitné, balené, surové, vyrobené, teplé, podzemní, povrchové, technologické a průmyslové, odpadní, vodný výluh, absorpční roztoky (emise, vnitřní a pracovní ovzduší)","methodology":"Oznaczanie formaldehydu metodą spektrofotometryczną","methodology_en":"Determination of formaldehyde by spectrophotometry","methodology_zh":"甲醛测定（分光光度法）","methodology_cs":"Stanovení formaldehydu spektrofotometricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie formaldehydu metodą spektrofotometryczną","reference":"ZP 051 (návod firmy Hach)","norm_bases":["ZP 051","návod firmy Hach"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody: przeznaczone do spożycia, butelkowane, surowe, uzdatnione, ciepłe, podziemne, powierzchniowe, technologiczne i przemysłowe, ścieki, wyciąg wodny, roztwory absorpcyjne (emisje, powietrze wewnętrzne i na stanowiskach pracy) Oznaczanie formaldehydu metodą spektrofotometryczną Vody pitné, balené, surové, vyrobené, teplé, podzemní, povrchové, technologické a průmyslové, odpadní, vodný výluh, absorpční roztoky (emise, vnitřní a pracovní ovzduší) Stanovení formaldehydu spektrofotometricky ZP 051 (návod firmy Hach) Wody: przeznaczone do spozycia, butelkowane, surowe, uzdatnione, cieple, podziemne, powierzchniowe, technologiczne i przemyslowe, scieki, wyciag wodny, roztwory absorpcyjne (emisje, powietrze wewnetrzne i na stanowiskach pracy) Oznaczanie formaldehydu metoda spektrofotometryczna Vody pitne, balene, surove, vyrobene, teple, podzemni, povrchove, technologicke a prumyslove, odpadni, vodny vyluh, absorpcni roztoky (emise, vnitrni a pracovni ovzdusi) Stanoveni formaldehydu spektrofotometricky ZP 051 (navod firmy Hach)","search_en":"Drinking, bottled, raw, treated, hot, ground, surface, process and industrial, waste water, aqueous leachate, absorption solutions (emissions, indoor and workplace air) Determination of formaldehyde by spectrophotometry ZP 051 (návod firmy Hach)","search_zh":"饮用水、瓶装水、原水、成品水、热水、地下水、地表水、工艺和工业用水、废水、水浸出液、吸收液（排放、室内和工作场所空气） 甲醛测定（分光光度法） ZP 051 (návod firmy Hach)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":46,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"f45cf10608058b1dbf8a8729","lab_id":"69ad52a4de79e566650fd33a","country":"CZ","accr_number":"1277","accr_body":"ČIA","row_label":"48","test_object":"Wody: przeznaczone do spożycia, butelkowane, surowe, uzdatnione, ciepłe, podziemne, powierzchniowe, w kąpieliskach i do celów leczniczych, technologiczne i przemysłowe, ścieki, wyciąg wodny, roztwory absorpcyjne (emisje, powietrze wewnętrzne i na stanowiskach pracy)","test_object_en":"Drinking, bottled, raw, treated, hot, ground, surface, bathing and therapeutic, process and industrial, waste water, aqueous leachate, absorption solutions (emissions, indoor and workplace air)","test_object_zh":"饮用水、瓶装水、原水、成品水、热水、地下水、地表水、游泳/浴用和医疗用水、工艺和工业用水、废水、水浸出液、吸收液（排放、室内和工作场所空气）","test_object_cs":"Vody pitné, balené, surové, vyrobené, teplé, podzemní, povrchové, ke koupání a léčebným účelům, technologické a průmyslové, odpadní, vodný výluh, absorpční roztoky (emise, vnitřní a pracovní ovzduší)","methodology":"Oznaczanie radonu 222Rn w próbkach wód przez pomiar promieniowania gamma","methodology_en":"Determination of radon 222Rn in water samples by gamma radiation measurement","methodology_zh":"γ辐射测量法测定水样中氡222Rn","methodology_cs":"Stanovení radonu 222Rn ve vzorcích vod měřením záření gama","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie radonu 222Rn w próbkach wód przez pomiar promieniowania gamma","reference":"ZP 105 (ČSN 75 7624; ČSN 75 7600; návod firmy Diram)","norm_bases":["ZP 105","ČSN 75 7624","ČSN 75 7600","návod firmy Diram"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody: przeznaczone do spożycia, butelkowane, surowe, uzdatnione, ciepłe, podziemne, powierzchniowe, w kąpieliskach i do celów leczniczych, technologiczne i przemysłowe, ścieki, wyciąg wodny, roztwory absorpcyjne (emisje, powietrze wewnętrzne i na stanowiskach pracy) Oznaczanie radonu 222Rn w próbkach wód przez pomiar promieniowania gamma Vody pitné, balené, surové, vyrobené, teplé, podzemní, povrchové, ke koupání a léčebným účelům, technologické a průmyslové, odpadní, vodný výluh, absorpční roztoky (emise, vnitřní a pracovní ovzduší) Stanovení radonu 222Rn ve vzorcích vod měřením záření gama ZP 105 (ČSN 75 7624; ČSN 75 7600; návod firmy Diram) Wody: przeznaczone do spozycia, butelkowane, surowe, uzdatnione, cieple, podziemne, powierzchniowe, w kapieliskach i do celow leczniczych, technologiczne i przemyslowe, scieki, wyciag wodny, roztwory absorpcyjne (emisje, powietrze wewnetrzne i na stanowiskach pracy) Oznaczanie radonu 222Rn w probkach wod przez pomiar promieniowania gamma Vody pitne, balene, surove, vyrobene, teple, podzemni, povrchove, ke koupani a lecebnym ucelum, technologicke a prumyslove, odpadni, vodny vyluh, absorpcni roztoky (emise, vnitrni a pracovni ovzdusi) Stanoveni radonu 222Rn ve vzorcich vod merenim zareni gama ZP 105 (CSN 75 7624; CSN 75 7600; navod firmy Diram)","search_en":"Drinking, bottled, raw, treated, hot, ground, surface, bathing and therapeutic, process and industrial, waste water, aqueous leachate, absorption solutions (emissions, indoor and workplace air) Determination of radon 222Rn in water samples by gamma radiation measurement ZP 105 (ČSN 75 7624; ČSN 75 7600; návod firmy Diram)","search_zh":"饮用水、瓶装水、原水、成品水、热水、地下水、地表水、游泳/浴用和医疗用水、工艺和工业用水、废水、水浸出液、吸收液（排放、室内和工作场所空气） γ辐射测量法测定水样中氡222Rn ZP 105 (ČSN 75 7624; ČSN 75 7600; návod firmy Diram)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":47,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"b8b2533097326214a0fb9e66","lab_id":"69ad52a4de79e566650fd33a","country":"CZ","accr_number":"1277","accr_body":"ČIA","row_label":"49","test_object":"Wody: przeznaczone do spożycia, butelkowane, surowe, uzdatnione, ciepłe, podziemne","test_object_en":"Drinking, bottled, raw, treated, hot, ground water","test_object_zh":"饮用水、瓶装水、原水、成品水、热水、地下水","test_object_cs":"Vody pitné, balené, surové, vyrobené, teplé, podzemní","methodology":"Oznaczanie całkowitej aktywności objętościowej beta przez pomiar pozostałości po odparowaniu detektorem proporcjonalnym i całkowitej aktywności beta skorygowanej o potas 40 obliczeniowo oraz obliczanie całkowitej dawki orientacyjnej","methodology_en":"Determination of gross beta activity concentration by measuring the evaporation residue with a proportional detector and of gross beta activity corrected for potassium 40 by calculation, and calculation of the total indicative dose","methodology_zh":"正比计数器测量蒸发残渣总β放射性浓度、计算扣除钾40的总β活度及总指示剂量","methodology_cs":"Stanovení celkové objemové aktivity beta měřením odparku proporcionálním detektorem a celkové objemové aktivity beta korigované na draslík 40 výpočtem z naměřených hodnot a dopočet celkové indikativní dávky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie całkowitej aktywności objętościowej beta przez pomiar pozostałości po odparowaniu detektorem proporcjonalnym i całkowitej aktywności beta skorygowanej o potas 40 obliczeniowo oraz obliczanie całkowitej dawki orientacyjnej","reference":"ZP 085 (ČSN 75 7612; ČSN 75 7600; ČSN EN ISO 5667-3; návod firmy Empos; doporučení SÚJB)","norm_bases":["ZP 085","ČSN 75 7612","ČSN 75 7600","ČSN EN ISO 5667-3","návod firmy Empos","doporučení SÚJB"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Zalecenie SÚJB DR-RO-5.1 (Rev. 0.0): pomiar i ocena zawartości naturalnych radionuklidów w wodzie przeznaczonej do spożycia i w wodzie butelkowanej","note_en":"SÚJB recommendation DR-RO-5.1 (Rev. 0.0): measurement and assessment of natural radionuclides in public drinking water and bottled water","note_zh":"捷克国家核安全局建议DR-RO-5.1（Rev. 0.0）：公共饮用水和瓶装水中天然放射性核素的测量和评估","note_cs":"Doporučení SÚJB DR-RO-5.1(Rev. 0.0) Měření a hodnocení obsahu přírodních radionuklidů v pitné vodě pro veřejnou potřebu a v balené vodě","search_text":"Wody: przeznaczone do spożycia, butelkowane, surowe, uzdatnione, ciepłe, podziemne Oznaczanie całkowitej aktywności objętościowej beta przez pomiar pozostałości po odparowaniu detektorem proporcjonalnym i całkowitej aktywności beta skorygowanej o potas 40 obliczeniowo oraz obliczanie całkowitej dawki orientacyjnej Vody pitné, balené, surové, vyrobené, teplé, podzemní Stanovení celkové objemové aktivity beta měřením odparku proporcionálním detektorem a celkové objemové aktivity beta korigované na draslík 40 výpočtem z naměřených hodnot a dopočet celkové indikativní dávky ZP 085 (ČSN 75 7612; ČSN 75 7600; ČSN EN ISO 5667-3; návod firmy Empos; doporučení SÚJB) Wody: przeznaczone do spozycia, butelkowane, surowe, uzdatnione, cieple, podziemne Oznaczanie calkowitej aktywnosci objetosciowej beta przez pomiar pozostalosci po odparowaniu detektorem proporcjonalnym i calkowitej aktywnosci beta skorygowanej o potas 40 obliczeniowo oraz obliczanie calkowitej dawki orientacyjnej Vody pitne, balene, surove, vyrobene, teple, podzemni Stanoveni celkove objemove aktivity beta merenim odparku proporcionalnim detektorem a celkove objemove aktivity beta korigovane na draslik 40 vypoctem z namerenych hodnot a dopocet celkove indikativni davky ZP 085 (CSN 75 7612; CSN 75 7600; CSN EN ISO 5667-3; navod firmy Empos; doporuceni SUJB)","search_en":"Drinking, bottled, raw, treated, hot, ground water Determination of gross beta activity concentration by measuring the evaporation residue with a proportional detector and of gross beta activity corrected for potassium 40 by calculation, and calculation of the total indicative dose ZP 085 (ČSN 75 7612; ČSN 75 7600; ČSN EN ISO 5667-3; návod firmy Empos; doporučení SÚJB)","search_zh":"饮用水、瓶装水、原水、成品水、热水、地下水 正比计数器测量蒸发残渣总β放射性浓度、计算扣除钾40的总β活度及总指示剂量 ZP 085 (ČSN 75 7612; ČSN 75 7600; ČSN EN ISO 5667-3; návod firmy Empos; doporučení SÚJB)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":48,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"8f3183835da7415196cecba0","lab_id":"69ad52a4de79e566650fd33a","country":"CZ","accr_number":"1277","accr_body":"ČIA","row_label":"50","test_object":"Wody: przeznaczone do spożycia, butelkowane, surowe, uzdatnione, ciepłe, podziemne","test_object_en":"Drinking, bottled, raw, treated, hot, ground water","test_object_zh":"饮用水、瓶装水、原水、成品水、热水、地下水","test_object_cs":"Vody pitné, balené, surové, vyrobené, teplé, podzemní","methodology":"Oznaczanie całkowitej aktywności objętościowej alfa przez pomiar mieszaniny pozostałości ze scyntylatorem ZnS (Ag) i całkowitej aktywności alfa skorygowanej o uran obliczeniowo","methodology_en":"Determination of gross alpha activity concentration by measuring the evaporation residue mixed with ZnS (Ag) scintillator and of gross alpha activity corrected for uranium by calculation","methodology_zh":"ZnS(Ag)闪烁体法测定总α放射性浓度及计算扣除铀的总α活度","methodology_cs":"Stanovení celkové objemové aktivity alfa měřením směsi odparku se scintilátorem ZnS (Ag) a celkového objemové aktivity alfa korigované na uran výpočtem z naměřených hodnot","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie całkowitej aktywności objętościowej alfa przez pomiar mieszaniny pozostałości ze scyntylatorem ZnS (Ag) i całkowitej aktywności alfa skorygowanej o uran obliczeniowo","reference":"ZP 106 (ČSN 75 7611; ČSN 75 7600; ČSN EN ISO 5667-3; návod firmy Diram; doporučení SÚJB)","norm_bases":["ZP 106","ČSN 75 7611","ČSN 75 7600","ČSN EN ISO 5667-3","návod firmy Diram","doporučení SÚJB"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Zalecenie SÚJB DR-RO-5.1 (Rev. 0.0): pomiar i ocena zawartości naturalnych radionuklidów w wodzie przeznaczonej do spożycia i w wodzie butelkowanej","note_en":"SÚJB recommendation DR-RO-5.1 (Rev. 0.0): measurement and assessment of natural radionuclides in public drinking water and bottled water","note_zh":"捷克国家核安全局建议DR-RO-5.1（Rev. 0.0）：公共饮用水和瓶装水中天然放射性核素的测量和评估","note_cs":"Doporučení SÚJB DR-RO-5.1(Rev. 0.0) Měření a hodnocení obsahu přírodních radionuklidů v pitné vodě pro veřejnou potřebu a v balené vodě","search_text":"Wody: przeznaczone do spożycia, butelkowane, surowe, uzdatnione, ciepłe, podziemne Oznaczanie całkowitej aktywności objętościowej alfa przez pomiar mieszaniny pozostałości ze scyntylatorem ZnS (Ag) i całkowitej aktywności alfa skorygowanej o uran obliczeniowo Vody pitné, balené, surové, vyrobené, teplé, podzemní Stanovení celkové objemové aktivity alfa měřením směsi odparku se scintilátorem ZnS (Ag) a celkového objemové aktivity alfa korigované na uran výpočtem z naměřených hodnot ZP 106 (ČSN 75 7611; ČSN 75 7600; ČSN EN ISO 5667-3; návod firmy Diram; doporučení SÚJB) Wody: przeznaczone do spozycia, butelkowane, surowe, uzdatnione, cieple, podziemne Oznaczanie calkowitej aktywnosci objetosciowej alfa przez pomiar mieszaniny pozostalosci ze scyntylatorem ZnS (Ag) i calkowitej aktywnosci alfa skorygowanej o uran obliczeniowo Vody pitne, balene, surove, vyrobene, teple, podzemni Stanoveni celkove objemove aktivity alfa merenim smesi odparku se scintilatorem ZnS (Ag) a celkoveho objemove aktivity alfa korigovane na uran vypoctem z namerenych hodnot ZP 106 (CSN 75 7611; CSN 75 7600; CSN EN ISO 5667-3; navod firmy Diram; doporuceni SUJB)","search_en":"Drinking, bottled, raw, treated, hot, ground water Determination of gross alpha activity concentration by measuring the evaporation residue mixed with ZnS (Ag) scintillator and of gross alpha activity corrected for uranium by calculation ZP 106 (ČSN 75 7611; ČSN 75 7600; ČSN EN ISO 5667-3; návod firmy Diram; doporučení SÚJB)","search_zh":"饮用水、瓶装水、原水、成品水、热水、地下水 ZnS(Ag)闪烁体法测定总α放射性浓度及计算扣除铀的总α活度 ZP 106 (ČSN 75 7611; ČSN 75 7600; ČSN EN ISO 5667-3; návod firmy Diram; doporučení SÚJB)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":49,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"f8c1300603f05aa1b73a302f","lab_id":"69ad52a4de79e566650fd33a","country":"CZ","accr_number":"1277","accr_body":"ČIA","row_label":"51","test_object":"Wody: przeznaczone do spożycia, butelkowane, surowe, uzdatnione, ciepłe, podziemne, powierzchniowe, technologiczne i przemysłowe, ścieki, wyciąg wodny","test_object_en":"Drinking, bottled, raw, treated, hot, ground, surface, process and industrial, waste water, aqueous leachate","test_object_zh":"饮用水、瓶装水、原水、成品水、热水、地下水、地表水、工艺和工业用水、废水、水浸出液","test_object_cs":"Vody pitné, balené, surové, vyrobené, teplé, podzemní, povrchové, technologické a průmyslové, odpadní, vodný výluh","methodology":"Oznaczanie adsorbowalnych halogenów organicznie związanych (AOX) metodą kulometryczną","methodology_en":"Determination of adsorbable organically bound halogens (AOX) by coulometry","methodology_zh":"可吸附有机卤素（AOX）测定（库仑法）","methodology_cs":"Stanovení adsorbovatelných organicky vázaných halogenů (AOX) coulometricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie adsorbowalnych halogenów organicznie związanych (AOX) metodą kulometryczną","reference":"ZP 071a (ČSN EN ISO 9562; ČSN EN 16166)","norm_bases":["ZP 071a","ČSN EN ISO 9562","ČSN EN 16166"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody: przeznaczone do spożycia, butelkowane, surowe, uzdatnione, ciepłe, podziemne, powierzchniowe, technologiczne i przemysłowe, ścieki, wyciąg wodny Oznaczanie adsorbowalnych halogenów organicznie związanych (AOX) metodą kulometryczną Vody pitné, balené, surové, vyrobené, teplé, podzemní, povrchové, technologické a průmyslové, odpadní, vodný výluh Stanovení adsorbovatelných organicky vázaných halogenů (AOX) coulometricky ZP 071a (ČSN EN ISO 9562; ČSN EN 16166) Wody: przeznaczone do spozycia, butelkowane, surowe, uzdatnione, cieple, podziemne, powierzchniowe, technologiczne i przemyslowe, scieki, wyciag wodny Oznaczanie adsorbowalnych halogenow organicznie zwiazanych (AOX) metoda kulometryczna Vody pitne, balene, surove, vyrobene, teple, podzemni, povrchove, technologicke a prumyslove, odpadni, vodny vyluh Stanoveni adsorbovatelnych organicky vazanych halogenu (AOX) coulometricky ZP 071a (CSN EN ISO 9562; CSN EN 16166)","search_en":"Drinking, bottled, raw, treated, hot, ground, surface, process and industrial, waste water, aqueous leachate Determination of adsorbable organically bound halogens (AOX) by coulometry ZP 071a (ČSN EN ISO 9562; ČSN EN 16166)","search_zh":"饮用水、瓶装水、原水、成品水、热水、地下水、地表水、工艺和工业用水、废水、水浸出液 可吸附有机卤素（AOX）测定（库仑法） ZP 071a (ČSN EN ISO 9562; ČSN EN 16166)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":50,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"73bd7ece239dd1359c3ff5fc","lab_id":"69ad52a4de79e566650fd33a","country":"CZ","accr_number":"1277","accr_body":"ČIA","row_label":"52","test_object":"Grunty, gleby, osady, osady denne, komposty, odpady, piaski","test_object_en":"Earths, soils, sludge, sediments, composts, waste, sands","test_object_zh":"土、土壤、污泥、沉积物、堆肥、废物、砂","test_object_cs":"Zeminy, půdy, kaly, sedimenty, komposty, odpady, písky","methodology":"Oznaczanie adsorbowalnych halogenów organicznie związanych (AOX) metodą kulometryczną","methodology_en":"Determination of adsorbable organically bound halogens (AOX) by coulometry","methodology_zh":"可吸附有机卤素（AOX）测定（库仑法）","methodology_cs":"Stanovení adsorbovatelných organicky vázaných halogenů (AOX) coulometricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie adsorbowalnych halogenów organicznie związanych (AOX) metodą kulometryczną","reference":"ZP 071b (ČSN EN ISO 9562; ČSN EN 16166)","norm_bases":["ZP 071b","ČSN EN ISO 9562","ČSN EN 16166"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Grunty, gleby, osady, osady denne, komposty, odpady, piaski Oznaczanie adsorbowalnych halogenów organicznie związanych (AOX) metodą kulometryczną Zeminy, půdy, kaly, sedimenty, komposty, odpady, písky Stanovení adsorbovatelných organicky vázaných halogenů (AOX) coulometricky ZP 071b (ČSN EN ISO 9562; ČSN EN 16166) Grunty, gleby, osady, osady denne, komposty, odpady, piaski Oznaczanie adsorbowalnych halogenow organicznie zwiazanych (AOX) metoda kulometryczna Zeminy, pudy, kaly, sedimenty, komposty, odpady, pisky Stanoveni adsorbovatelnych organicky vazanych halogenu (AOX) coulometricky ZP 071b (CSN EN ISO 9562; CSN EN 16166)","search_en":"Earths, soils, sludge, sediments, composts, waste, sands Determination of adsorbable organically bound halogens (AOX) by coulometry ZP 071b (ČSN EN ISO 9562; ČSN EN 16166)","search_zh":"土、土壤、污泥、沉积物、堆肥、废物、砂 可吸附有机卤素（AOX）测定（库仑法） ZP 071b (ČSN EN ISO 9562; ČSN EN 16166)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":51,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"37ff0cd89c994f7b8303f7b1","lab_id":"69ad52a4de79e566650fd33a","country":"CZ","accr_number":"1277","accr_body":"ČIA","row_label":"53","test_object":"Wody: przeznaczone do spożycia, butelkowane, surowe, uzdatnione, ciepłe, podziemne, powierzchniowe, w kąpieliskach i do celów leczniczych, technologiczne i przemysłowe, ścieki, wyciąg wodny, grunty, gleby, osady, osady denne, komposty, odpady, piaski, produkty roślinne, żywność, suplementy diety","test_object_en":"Drinking, bottled, raw, treated, hot, ground, surface, bathing and therapeutic, process and industrial, waste water, aqueous leachate, earths, soils, sludge, sediments, composts, waste, sands, plant products, food, food supplements","test_object_zh":"饮用水、瓶装水、原水、成品水、热水、地下水、地表水、游泳/浴用和医疗用水、工艺和工业用水、废水、水浸出液、土、土壤、污泥、沉积物、堆肥、废物、砂、植物产品、食品、膳食补充剂","test_object_cs":"Vody pitné, balené, surové, vyrobené, teplé, podzemní, povrchové, ke koupání a léčebným účelům, technologické a průmyslové, odpadní, vodný výluh, zeminy, půdy, kaly, sedimenty, komposty, odpady, písky, rostlinné produkty, potraviny, potravinové doplňky","methodology":"Oznaczanie rtęci ogólnej jednozadaniowym absorpcyjnym spektrometrem atomowym","methodology_en":"Determination of total mercury with a dedicated atomic absorption spectrometer","methodology_zh":"专用原子吸收测汞仪测定总汞","methodology_cs":"Stanovení veškeré rtuti jednoúčelovým atomovým absorpčním spektrofotometrem","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie rtęci ogólnej jednozadaniowym absorpcyjnym spektrometrem atomowym","reference":"ZP 072 (ČSN 75 7440)","norm_bases":["ZP 072","ČSN 75 7440"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody: przeznaczone do spożycia, butelkowane, surowe, uzdatnione, ciepłe, podziemne, powierzchniowe, w kąpieliskach i do celów leczniczych, technologiczne i przemysłowe, ścieki, wyciąg wodny, grunty, gleby, osady, osady denne, komposty, odpady, piaski, produkty roślinne, żywność, suplementy diety Oznaczanie rtęci ogólnej jednozadaniowym absorpcyjnym spektrometrem atomowym Vody pitné, balené, surové, vyrobené, teplé, podzemní, povrchové, ke koupání a léčebným účelům, technologické a průmyslové, odpadní, vodný výluh, zeminy, půdy, kaly, sedimenty, komposty, odpady, písky, rostlinné produkty, potraviny, potravinové doplňky Stanovení veškeré rtuti jednoúčelovým atomovým absorpčním spektrofotometrem ZP 072 (ČSN 75 7440) Wody: przeznaczone do spozycia, butelkowane, surowe, uzdatnione, cieple, podziemne, powierzchniowe, w kapieliskach i do celow leczniczych, technologiczne i przemyslowe, scieki, wyciag wodny, grunty, gleby, osady, osady denne, komposty, odpady, piaski, produkty roslinne, zywnosc, suplementy diety Oznaczanie rteci ogolnej jednozadaniowym absorpcyjnym spektrometrem atomowym Vody pitne, balene, surove, vyrobene, teple, podzemni, povrchove, ke koupani a lecebnym ucelum, technologicke a prumyslove, odpadni, vodny vyluh, zeminy, pudy, kaly, sedimenty, komposty, odpady, pisky, rostlinne produkty, potraviny, potravinove doplnky Stanoveni veskere rtuti jednoucelovym atomovym absorpcnim spektrofotometrem ZP 072 (CSN 75 7440)","search_en":"Drinking, bottled, raw, treated, hot, ground, surface, bathing and therapeutic, process and industrial, waste water, aqueous leachate, earths, soils, sludge, sediments, composts, waste, sands, plant products, food, food supplements Determination of total mercury with a dedicated atomic absorption spectrometer ZP 072 (ČSN 75 7440)","search_zh":"饮用水、瓶装水、原水、成品水、热水、地下水、地表水、游泳/浴用和医疗用水、工艺和工业用水、废水、水浸出液、土、土壤、污泥、沉积物、堆肥、废物、砂、植物产品、食品、膳食补充剂 专用原子吸收测汞仪测定总汞 ZP 072 (ČSN 75 7440)","categories":["water","environment","food"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":52,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"30e8abd919f1e74d1cde80e2","lab_id":"69ad52a4de79e566650fd33a","country":"CZ","accr_number":"1277","accr_body":"ČIA","row_label":"54","test_object":"Wody: przeznaczone do spożycia, butelkowane, surowe, uzdatnione, ciepłe, podziemne, powierzchniowe, w kąpieliskach i do celów leczniczych, technologiczne i przemysłowe, ścieki, wyciąg wodny","test_object_en":"Drinking, bottled, raw, treated, hot, ground, surface, bathing and therapeutic, process and industrial, waste water, aqueous leachate","test_object_zh":"饮用水、瓶装水、原水、成品水、热水、地下水、地表水、游泳/浴用和医疗用水、工艺和工业用水、废水、水浸出液","test_object_cs":"Vody pitné, balené, surové, vyrobené, teplé, podzemní, povrchové, ke koupání a léčebným účelům, technologické a průmyslové, odpadní, vodný výluh","methodology":"Oznaczanie lotnych związków organicznych metodą GC/FID/ECD i obliczanie sumy BTEX, CU i TOL","methodology_en":"Determination of volatile organic compounds by GC/FID/ECD and calculation of the sum of BTEX, CU and TOL","methodology_zh":"GC/FID/ECD法测定挥发性有机物及BTEX、氯代烃和挥发性有机物总和计算","methodology_cs":"Stanovení těkavých organických látek metodou GC/FID/ECD a dopočet sumy BTEX, CU a TOL","parameters":[{"name":"chloroeten","range":""},{"name":"1,1-dichloroeten","range":""},{"name":"dichlorometan","range":""},{"name":"cis-1,2-dichloroeten","range":""},{"name":"trans-1,2-dichloroeten","range":""},{"name":"chloroform","range":""},{"name":"tetrachlorometan","range":""},{"name":"1,2-dichloroetan","range":""},{"name":"trichloroetylen","range":""},{"name":"bromodichlorometan","range":""},{"name":"tetrachloroetylen","range":""},{"name":"dibromochlorometan","range":""},{"name":"bromoform","range":""},{"name":"o-dichlorobenzen","range":""},{"name":"m-dichlorobenzen","range":""},{"name":"p-dichlorobenzen","range":""},{"name":"benzen","range":""},{"name":"toluen","range":""},{"name":"chlorobenzen","range":""},{"name":"etylobenzen","range":""},{"name":"o-ksylen","range":""},{"name":"m-ksylen","range":""},{"name":"p-ksylen","range":""},{"name":"styren","range":""}],"parameters_en":[{"name":"chloroethene","range":""},{"name":"1,1-dichloroethene","range":""},{"name":"dichloromethane","range":""},{"name":"cis-1,2-dichloroethene","range":""},{"name":"trans-1,2-dichloroethene","range":""},{"name":"chloroform","range":""},{"name":"tetrachloromethane","range":""},{"name":"1,2-dichloroethane","range":""},{"name":"trichloroethylene","range":""},{"name":"bromodichloromethane","range":""},{"name":"tetrachloroethylene","range":""},{"name":"dibromochloromethane","range":""},{"name":"bromoform","range":""},{"name":"o-dichlorobenzene","range":""},{"name":"m-dichlorobenzene","range":""},{"name":"p-dichlorobenzene","range":""},{"name":"benzene","range":""},{"name":"toluene","range":""},{"name":"chlorobenzene","range":""},{"name":"ethylbenzene","range":""},{"name":"o-xylene","range":""},{"name":"m-xylene","range":""},{"name":"p-xylene","range":""},{"name":"styrene","range":""}],"parameters_zh":[{"name":"氯乙烯","range":""},{"name":"1,1-二氯乙烯","range":""},{"name":"二氯甲烷","range":""},{"name":"顺式-1,2-二氯乙烯","range":""},{"name":"反式-1,2-二氯乙烯","range":""},{"name":"氯仿","range":""},{"name":"四氯化碳","range":""},{"name":"1,2-二氯乙烷","range":""},{"name":"三氯乙烯","range":""},{"name":"一溴二氯甲烷","range":""},{"name":"四氯乙烯","range":""},{"name":"二溴一氯甲烷","range":""},{"name":"溴仿","range":""},{"name":"邻二氯苯","range":""},{"name":"间二氯苯","range":""},{"name":"对二氯苯","range":""},{"name":"苯","range":""},{"name":"甲苯","range":""},{"name":"氯苯","range":""},{"name":"乙苯","range":""},{"name":"邻二甲苯","range":""},{"name":"间二甲苯","range":""},{"name":"对二甲苯","range":""},{"name":"苯乙烯","range":""}],"parameters_cs":[{"name":"chlorethen","range":""},{"name":"1,1-dichlorethen","range":""},{"name":"dichlormethan","range":""},{"name":"cis-1,2-dichlorethen","range":""},{"name":"trans-1,2-dichlorethen","range":""},{"name":"chloroform","range":""},{"name":"tetrachlormethan","range":""},{"name":"1,2-dichlorethan","range":""},{"name":"trichlorethylen","range":""},{"name":"bromdichlormethan","range":""},{"name":"tetrachlorethylen","range":""},{"name":"dibromchlormethan","range":""},{"name":"bromoform","range":""},{"name":"o-dichlorbenzen","range":""},{"name":"m-dichlorbenzen","range":""},{"name":"p-dichlorbenzen","range":""},{"name":"benzen","range":""},{"name":"toluen","range":""},{"name":"chlorbenzen","range":""},{"name":"ethylbenzen","range":""},{"name":"o-xylen","range":""},{"name":"m-xylen","range":""},{"name":"p-xylen","range":""},{"name":"styren","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie lotnych związków organicznych metodą GC/FID/ECD i obliczanie sumy BTEX, CU i TOL\nZakres:\nchloroeten\n1,1-dichloroeten\ndichlorometan\ncis-1,2-dichloroeten\ntrans-1,2-dichloroeten\nchloroform\ntetrachlorometan\n1,2-dichloroetan\ntrichloroetylen\nbromodichlorometan\ntetrachloroetylen\ndibromochlorometan\nbromoform\no-dichlorobenzen\nm-dichlorobenzen\np-dichlorobenzen\nbenzen\ntoluen\nchlorobenzen\netylobenzen\no-ksylen\nm-ksylen\np-ksylen\nstyren","reference":"ZP 073a (TNV 75 7552; ČSN EN ISO 22155)","norm_bases":["ZP 073a","TNV 75 7552","ČSN EN ISO 22155"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody: przeznaczone do spożycia, butelkowane, surowe, uzdatnione, ciepłe, podziemne, powierzchniowe, w kąpieliskach i do celów leczniczych, technologiczne i przemysłowe, ścieki, wyciąg wodny Oznaczanie lotnych związków organicznych metodą GC/FID/ECD i obliczanie sumy BTEX, CU i TOL chloroeten  1,1-dichloroeten  dichlorometan  cis-1,2-dichloroeten  trans-1,2-dichloroeten  chloroform  tetrachlorometan  1,2-dichloroetan  trichloroetylen  bromodichlorometan  tetrachloroetylen  dibromochlorometan  bromoform  o-dichlorobenzen  m-dichlorobenzen  p-dichlorobenzen  benzen  toluen  chlorobenzen  etylobenzen  o-ksylen  m-ksylen  p-ksylen  styren  Vody pitné, balené, surové, vyrobené, teplé, podzemní, povrchové, ke koupání a léčebným účelům, technologické a průmyslové, odpadní, vodný výluh Stanovení těkavých organických látek metodou GC/FID/ECD a dopočet sumy BTEX, CU a TOL chlorethen  1,1-dichlorethen  dichlormethan  cis-1,2-dichlorethen  trans-1,2-dichlorethen  chloroform  tetrachlormethan  1,2-dichlorethan  trichlorethylen  bromdichlormethan  tetrachlorethylen  dibromchlormethan  bromoform  o-dichlorbenzen  m-dichlorbenzen  p-dichlorbenzen  benzen  toluen  chlorbenzen  ethylbenzen  o-xylen  m-xylen  p-xylen  styren  ZP 073a (TNV 75 7552; ČSN EN ISO 22155) Wody: przeznaczone do spozycia, butelkowane, surowe, uzdatnione, cieple, podziemne, powierzchniowe, w kapieliskach i do celow leczniczych, technologiczne i przemyslowe, scieki, wyciag wodny Oznaczanie lotnych zwiazkow organicznych metoda GC/FID/ECD i obliczanie sumy BTEX, CU i TOL chloroeten  1,1-dichloroeten  dichlorometan  cis-1,2-dichloroeten  trans-1,2-dichloroeten  chloroform  tetrachlorometan  1,2-dichloroetan  trichloroetylen  bromodichlorometan  tetrachloroetylen  dibromochlorometan  bromoform  o-dichlorobenzen  m-dichlorobenzen  p-dichlorobenzen  benzen  toluen  chlorobenzen  etylobenzen  o-ksylen  m-ksylen  p-ksylen  styren  Vody pitne, balene, surove, vyrobene, teple, podzemni, povrchove, ke koupani a lecebnym ucelum, technologicke a prumyslove, odpadni, vodny vyluh Stanoveni tekavych organickych latek metodou GC/FID/ECD a dopocet sumy BTEX, CU a TOL chlorethen  1,1-dichlorethen  dichlormethan  cis-1,2-dichlorethen  trans-1,2-dichlorethen  chloroform  tetrachlormethan  1,2-dichlorethan  trichlorethylen  bromdichlormethan  tetrachlorethylen  dibromchlormethan  bromoform  o-dichlorbenzen  m-dichlorbenzen  p-dichlorbenzen  benzen  toluen  chlorbenzen  ethylbenzen  o-xylen  m-xylen  p-xylen  styren  ZP 073a (TNV 75 7552; CSN EN ISO 22155)","search_en":"Drinking, bottled, raw, treated, hot, ground, surface, bathing and therapeutic, process and industrial, waste water, aqueous leachate Determination of volatile organic compounds by GC/FID/ECD and calculation of the sum of BTEX, CU and TOL chloroethene  1,1-dichloroethene  dichloromethane  cis-1,2-dichloroethene  trans-1,2-dichloroethene  chloroform  tetrachloromethane  1,2-dichloroethane  trichloroethylene  bromodichloromethane  tetrachloroethylene  dibromochloromethane  bromoform  o-dichlorobenzene  m-dichlorobenzene  p-dichlorobenzene  benzene  toluene  chlorobenzene  ethylbenzene  o-xylene  m-xylene  p-xylene  styrene  ZP 073a (TNV 75 7552; ČSN EN ISO 22155)","search_zh":"饮用水、瓶装水、原水、成品水、热水、地下水、地表水、游泳/浴用和医疗用水、工艺和工业用水、废水、水浸出液 GC/FID/ECD法测定挥发性有机物及BTEX、氯代烃和挥发性有机物总和计算 氯乙烯  1,1-二氯乙烯  二氯甲烷  顺式-1,2-二氯乙烯  反式-1,2-二氯乙烯  氯仿  四氯化碳  1,2-二氯乙烷  三氯乙烯  一溴二氯甲烷  四氯乙烯  二溴一氯甲烷  溴仿  邻二氯苯  间二氯苯  对二氯苯  苯  甲苯  氯苯  乙苯  邻二甲苯  间二甲苯  对二甲苯  苯乙烯  ZP 073a (TNV 75 7552; ČSN EN ISO 22155)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":53,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"e34f68187d5209488f37d153","lab_id":"69ad52a4de79e566650fd33a","country":"CZ","accr_number":"1277","accr_body":"ČIA","row_label":"55","test_object":"Grunty, gleby, osady, osady denne, komposty, odpady, piaski","test_object_en":"Earths, soils, sludge, sediments, composts, waste, sands","test_object_zh":"土、土壤、污泥、沉积物、堆肥、废物、砂","test_object_cs":"Zeminy, půdy, kaly, sedimenty, komposty, odpady, písky","methodology":"Oznaczanie lotnych związków organicznych metodą GC/FID/ECD i obliczanie sumy BTEX, THM, CU i TOL","methodology_en":"Determination of volatile organic compounds by GC/FID/ECD and calculation of the sum of BTEX, THM, CU and TOL","methodology_zh":"GC/FID/ECD法测定挥发性有机物及BTEX、三卤甲烷、氯代烃和挥发性有机物总和计算","methodology_cs":"Stanovení těkavých organických látek metodou GC/FID/ECD a dopočet sumy BTEX, THM, CU a TOL","parameters":[{"name":"benzen","range":""},{"name":"trichloroetylen","range":""},{"name":"toluen","range":""},{"name":"tetrachloroetylen","range":""},{"name":"etylobenzen","range":""},{"name":"m+p-ksylen","range":""},{"name":"o-ksylen","range":""}],"parameters_en":[{"name":"benzene","range":""},{"name":"trichloroethylene","range":""},{"name":"toluene","range":""},{"name":"tetrachloroethylene","range":""},{"name":"ethylbenzene","range":""},{"name":"m+p-xylene","range":""},{"name":"o-xylene","range":""}],"parameters_zh":[{"name":"苯","range":""},{"name":"三氯乙烯","range":""},{"name":"甲苯","range":""},{"name":"四氯乙烯","range":""},{"name":"乙苯","range":""},{"name":"间+对二甲苯","range":""},{"name":"邻二甲苯","range":""}],"parameters_cs":[{"name":"benzen","range":""},{"name":"trichlorethylen","range":""},{"name":"toluen","range":""},{"name":"tetrachlorethylen","range":""},{"name":"ethylbenzen","range":""},{"name":"m+p-xylen","range":""},{"name":"o-xylen","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie lotnych związków organicznych metodą GC/FID/ECD i obliczanie sumy BTEX, THM, CU i TOL\nZakres:\nbenzen\ntrichloroetylen\ntoluen\ntetrachloroetylen\netylobenzen\nm+p-ksylen\no-ksylen","reference":"ZP 073b (TNV 75 7552; ČSN EN ISO 22155)","norm_bases":["ZP 073b","TNV 75 7552","ČSN EN ISO 22155"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Grunty, gleby, osady, osady denne, komposty, odpady, piaski Oznaczanie lotnych związków organicznych metodą GC/FID/ECD i obliczanie sumy BTEX, THM, CU i TOL benzen  trichloroetylen  toluen  tetrachloroetylen  etylobenzen  m+p-ksylen  o-ksylen  Zeminy, půdy, kaly, sedimenty, komposty, odpady, písky Stanovení těkavých organických látek metodou GC/FID/ECD a dopočet sumy BTEX, THM, CU a TOL benzen  trichlorethylen  toluen  tetrachlorethylen  ethylbenzen  m+p-xylen  o-xylen  ZP 073b (TNV 75 7552; ČSN EN ISO 22155) Grunty, gleby, osady, osady denne, komposty, odpady, piaski Oznaczanie lotnych zwiazkow organicznych metoda GC/FID/ECD i obliczanie sumy BTEX, THM, CU i TOL benzen  trichloroetylen  toluen  tetrachloroetylen  etylobenzen  m+p-ksylen  o-ksylen  Zeminy, pudy, kaly, sedimenty, komposty, odpady, pisky Stanoveni tekavych organickych latek metodou GC/FID/ECD a dopocet sumy BTEX, THM, CU a TOL benzen  trichlorethylen  toluen  tetrachlorethylen  ethylbenzen  m+p-xylen  o-xylen  ZP 073b (TNV 75 7552; CSN EN ISO 22155)","search_en":"Earths, soils, sludge, sediments, composts, waste, sands Determination of volatile organic compounds by GC/FID/ECD and calculation of the sum of BTEX, THM, CU and TOL benzene  trichloroethylene  toluene  tetrachloroethylene  ethylbenzene  m+p-xylene  o-xylene  ZP 073b (TNV 75 7552; ČSN EN ISO 22155)","search_zh":"土、土壤、污泥、沉积物、堆肥、废物、砂 GC/FID/ECD法测定挥发性有机物及BTEX、三卤甲烷、氯代烃和挥发性有机物总和计算 苯  三氯乙烯  甲苯  四氯乙烯  乙苯  间+对二甲苯  邻二甲苯  ZP 073b (TNV 75 7552; ČSN EN ISO 22155)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":54,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"cacea5cad3d794898fd2e8e2","lab_id":"69ad52a4de79e566650fd33a","country":"CZ","accr_number":"1277","accr_body":"ČIA","row_label":"56","test_object":"Wody: przeznaczone do spożycia, butelkowane, surowe, uzdatnione, ciepłe, podziemne, powierzchniowe, w kąpieliskach i do celów leczniczych, technologiczne i przemysłowe, ścieki","test_object_en":"Drinking, bottled, raw, treated, hot, ground, surface, bathing and therapeutic, process and industrial, waste water","test_object_zh":"饮用水、瓶装水、原水、成品水、热水、地下水、地表水、游泳/浴用和医疗用水、工艺和工业用水、废水","test_object_cs":"Vody pitné, balené, surové, vyrobené, teplé, podzemní, povrchové, ke koupání a léčebným účelům, technologické a průmyslové, odpadní","methodology":"Oznaczanie węglowodorów C10 do C40 metodą GC/FID","methodology_en":"Determination of hydrocarbons C10 to C40 by GC/FID","methodology_zh":"C10–C40烃类测定（GC/FID）","methodology_cs":"Stanovení uhlovodíků C10 až C40 metodou GC/FID","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie węglowodorów C10 do C40 metodą GC/FID","reference":"ZP 074a (ČSN EN ISO 9377-2)","norm_bases":["ZP 074a","ČSN EN ISO 9377-2"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody: przeznaczone do spożycia, butelkowane, surowe, uzdatnione, ciepłe, podziemne, powierzchniowe, w kąpieliskach i do celów leczniczych, technologiczne i przemysłowe, ścieki Oznaczanie węglowodorów C10 do C40 metodą GC/FID Vody pitné, balené, surové, vyrobené, teplé, podzemní, povrchové, ke koupání a léčebným účelům, technologické a průmyslové, odpadní Stanovení uhlovodíků C10 až C40 metodou GC/FID ZP 074a (ČSN EN ISO 9377-2) Wody: przeznaczone do spozycia, butelkowane, surowe, uzdatnione, cieple, podziemne, powierzchniowe, w kapieliskach i do celow leczniczych, technologiczne i przemyslowe, scieki Oznaczanie weglowodorow C10 do C40 metoda GC/FID Vody pitne, balene, surove, vyrobene, teple, podzemni, povrchove, ke koupani a lecebnym ucelum, technologicke a prumyslove, odpadni Stanoveni uhlovodiku C10 az C40 metodou GC/FID ZP 074a (CSN EN ISO 9377-2)","search_en":"Drinking, bottled, raw, treated, hot, ground, surface, bathing and therapeutic, process and industrial, waste water Determination of hydrocarbons C10 to C40 by GC/FID ZP 074a (ČSN EN ISO 9377-2)","search_zh":"饮用水、瓶装水、原水、成品水、热水、地下水、地表水、游泳/浴用和医疗用水、工艺和工业用水、废水 C10–C40烃类测定（GC/FID） ZP 074a (ČSN EN ISO 9377-2)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":55,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"e73bd3b83866a8b2b5eb4289","lab_id":"69ad52a4de79e566650fd33a","country":"CZ","accr_number":"1277","accr_body":"ČIA","row_label":"57","test_object":"Grunty, gleby, osady, osady denne, komposty, odpady, piaski","test_object_en":"Earths, soils, sludge, sediments, composts, waste, sands","test_object_zh":"土、土壤、污泥、沉积物、堆肥、废物、砂","test_object_cs":"Zeminy, půdy, kaly, sedimenty, komposty, odpady, písky","methodology":"Oznaczanie węglowodorów C10 do C40 metodą GC/FID","methodology_en":"Determination of hydrocarbons C10 to C40 by GC/FID","methodology_zh":"C10–C40烃类测定（GC/FID）","methodology_cs":"Stanovení uhlovodíků C10 až C40 metodou GC/FID","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie węglowodorów C10 do C40 metodą GC/FID","reference":"ZP 074b (ČSN EN 14039; ČSN EN ISO 16703)","norm_bases":["ZP 074b","ČSN EN 14039","ČSN EN ISO 16703"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Grunty, gleby, osady, osady denne, komposty, odpady, piaski Oznaczanie węglowodorów C10 do C40 metodą GC/FID Zeminy, půdy, kaly, sedimenty, komposty, odpady, písky Stanovení uhlovodíků C10 až C40 metodou GC/FID ZP 074b (ČSN EN 14039; ČSN EN ISO 16703) Grunty, gleby, osady, osady denne, komposty, odpady, piaski Oznaczanie weglowodorow C10 do C40 metoda GC/FID Zeminy, pudy, kaly, sedimenty, komposty, odpady, pisky Stanoveni uhlovodiku C10 az C40 metodou GC/FID ZP 074b (CSN EN 14039; CSN EN ISO 16703)","search_en":"Earths, soils, sludge, sediments, composts, waste, sands Determination of hydrocarbons C10 to C40 by GC/FID ZP 074b (ČSN EN 14039; ČSN EN ISO 16703)","search_zh":"土、土壤、污泥、沉积物、堆肥、废物、砂 C10–C40烃类测定（GC/FID） ZP 074b (ČSN EN 14039; ČSN EN ISO 16703)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":56,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"e59aa0a8d24679e54b075a50","lab_id":"69ad52a4de79e566650fd33a","country":"CZ","accr_number":"1277","accr_body":"ČIA","row_label":"58","test_object":"Wody: przeznaczone do spożycia, butelkowane, surowe, uzdatnione, ciepłe, podziemne, powierzchniowe, ścieki","test_object_en":"Drinking, bottled, raw, treated, hot, ground, surface, waste water","test_object_zh":"饮用水、瓶装水、原水、成品水、热水、地下水、地表水、废水","test_object_cs":"Vody pitné, balené, surové, vyrobené, teplé, podzemní, povrchové, odpadní","methodology":"Oznaczanie wielopierścieniowych węglowodorów aromatycznych metodą HPLC/FluD/DAD i obliczanie sumy WWA","methodology_en":"Determination of polycyclic aromatic hydrocarbons by HPLC/FluD/DAD and calculation of the sum of PAH","methodology_zh":"HPLC/FluD/DAD法测定多环芳烃及多环芳烃总和计算","methodology_cs":"Stanovení polycyklických aromatických uhlovodíků metodou HPLC/FluD/DAD a dopočet sumy PAU","parameters":[{"name":"fluoranten","range":""},{"name":"benzo(a)piren","range":""},{"name":"benzo(b)fluoranten","range":""},{"name":"benzo(g,h,i)perylen","range":""},{"name":"indeno(1,2,3-cd)piren","range":""},{"name":"benzo(k)fluoranten","range":""},{"name":"naftalen","range":""},{"name":"fenantren","range":""},{"name":"chryzen","range":""},{"name":"piren","range":""},{"name":"antracen","range":""},{"name":"benzo(a)antracen","range":""},{"name":"acenaftylen","range":""},{"name":"acenaften","range":""},{"name":"fluoren","range":""},{"name":"dibenzo(a,h)antracen","range":""}],"parameters_en":[{"name":"fluoranthene","range":""},{"name":"benzo(a)pyrene","range":""},{"name":"benzo(b)fluoranthene","range":""},{"name":"benzo(g,h,i)perylene","range":""},{"name":"indeno(1,2,3-cd)pyrene","range":""},{"name":"benzo(k)fluoranthene","range":""},{"name":"naphthalene","range":""},{"name":"phenanthrene","range":""},{"name":"chrysene","range":""},{"name":"pyrene","range":""},{"name":"anthracene","range":""},{"name":"benzo(a)anthracene","range":""},{"name":"acenaphthylene","range":""},{"name":"acenaphthene","range":""},{"name":"fluorene","range":""},{"name":"dibenzo(a,h)anthracene","range":""}],"parameters_zh":[{"name":"荧蒽","range":""},{"name":"苯并(a)芘","range":""},{"name":"苯并(b)荧蒽","range":""},{"name":"苯并(g,h,i)苝","range":""},{"name":"茚并(1,2,3-cd)芘","range":""},{"name":"苯并(k)荧蒽","range":""},{"name":"萘","range":""},{"name":"菲","range":""},{"name":"䓛","range":""},{"name":"芘","range":""},{"name":"蒽","range":""},{"name":"苯并(a)蒽","range":""},{"name":"苊烯","range":""},{"name":"苊","range":""},{"name":"芴","range":""},{"name":"二苯并(a,h)蒽","range":""}],"parameters_cs":[{"name":"fluoranthen","range":""},{"name":"benzo(a)pyren","range":""},{"name":"benzo(b)fluoranthen","range":""},{"name":"benzo(g,h,i)perylen","range":""},{"name":"indeno(1,2,3-cd)pyren","range":""},{"name":"benzo(k)fluoranthen","range":""},{"name":"naftalen","range":""},{"name":"fenanthren","range":""},{"name":"chrysen","range":""},{"name":"pyren","range":""},{"name":"antracen","range":""},{"name":"benzo(a)antracen","range":""},{"name":"acenaftylen","range":""},{"name":"acenaften","range":""},{"name":"fluoren","range":""},{"name":"dibenzo(a,h)antracen","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie wielopierścieniowych węglowodorów aromatycznych metodą HPLC/FluD/DAD i obliczanie sumy WWA\nZakres:\nfluoranten\nbenzo(a)piren\nbenzo(b)fluoranten\nbenzo(g,h,i)perylen\nindeno(1,2,3-cd)piren\nbenzo(k)fluoranten\nnaftalen\nfenantren\nchryzen\npiren\nantracen\nbenzo(a)antracen\nacenaftylen\nacenaften\nfluoren\ndibenzo(a,h)antracen","reference":"ZP 075a (ČSN EN ISO 17993)","norm_bases":["ZP 075a","ČSN EN ISO 17993"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody: przeznaczone do spożycia, butelkowane, surowe, uzdatnione, ciepłe, podziemne, powierzchniowe, ścieki Oznaczanie wielopierścieniowych węglowodorów aromatycznych metodą HPLC/FluD/DAD i obliczanie sumy WWA fluoranten  benzo(a)piren  benzo(b)fluoranten  benzo(g,h,i)perylen  indeno(1,2,3-cd)piren  benzo(k)fluoranten  naftalen  fenantren  chryzen  piren  antracen  benzo(a)antracen  acenaftylen  acenaften  fluoren  dibenzo(a,h)antracen  Vody pitné, balené, surové, vyrobené, teplé, podzemní, povrchové, odpadní Stanovení polycyklických aromatických uhlovodíků metodou HPLC/FluD/DAD a dopočet sumy PAU fluoranthen  benzo(a)pyren  benzo(b)fluoranthen  benzo(g,h,i)perylen  indeno(1,2,3-cd)pyren  benzo(k)fluoranthen  naftalen  fenanthren  chrysen  pyren  antracen  benzo(a)antracen  acenaftylen  acenaften  fluoren  dibenzo(a,h)antracen  ZP 075a (ČSN EN ISO 17993) Wody: przeznaczone do spozycia, butelkowane, surowe, uzdatnione, cieple, podziemne, powierzchniowe, scieki Oznaczanie wielopierscieniowych weglowodorow aromatycznych metoda HPLC/FluD/DAD i obliczanie sumy WWA fluoranten  benzo(a)piren  benzo(b)fluoranten  benzo(g,h,i)perylen  indeno(1,2,3-cd)piren  benzo(k)fluoranten  naftalen  fenantren  chryzen  piren  antracen  benzo(a)antracen  acenaftylen  acenaften  fluoren  dibenzo(a,h)antracen  Vody pitne, balene, surove, vyrobene, teple, podzemni, povrchove, odpadni Stanoveni polycyklickych aromatickych uhlovodiku metodou HPLC/FluD/DAD a dopocet sumy PAU fluoranthen  benzo(a)pyren  benzo(b)fluoranthen  benzo(g,h,i)perylen  indeno(1,2,3-cd)pyren  benzo(k)fluoranthen  naftalen  fenanthren  chrysen  pyren  antracen  benzo(a)antracen  acenaftylen  acenaften  fluoren  dibenzo(a,h)antracen  ZP 075a (CSN EN ISO 17993)","search_en":"Drinking, bottled, raw, treated, hot, ground, surface, waste water Determination of polycyclic aromatic hydrocarbons by HPLC/FluD/DAD and calculation of the sum of PAH fluoranthene  benzo(a)pyrene  benzo(b)fluoranthene  benzo(g,h,i)perylene  indeno(1,2,3-cd)pyrene  benzo(k)fluoranthene  naphthalene  phenanthrene  chrysene  pyrene  anthracene  benzo(a)anthracene  acenaphthylene  acenaphthene  fluorene  dibenzo(a,h)anthracene  ZP 075a (ČSN EN ISO 17993)","search_zh":"饮用水、瓶装水、原水、成品水、热水、地下水、地表水、废水 HPLC/FluD/DAD法测定多环芳烃及多环芳烃总和计算 荧蒽  苯并(a)芘  苯并(b)荧蒽  苯并(g,h,i)苝  茚并(1,2,3-cd)芘  苯并(k)荧蒽  萘  菲  䓛  芘  蒽  苯并(a)蒽  苊烯  苊  芴  二苯并(a,h)蒽  ZP 075a (ČSN EN ISO 17993)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":57,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"5fc2c03561133898fea94985","lab_id":"69ad52a4de79e566650fd33a","country":"CZ","accr_number":"1277","accr_body":"ČIA","row_label":"59","test_object":"Grunty, gleby, osady, osady denne, komposty, odpady, piaski","test_object_en":"Earths, soils, sludge, sediments, composts, waste, sands","test_object_zh":"土、土壤、污泥、沉积物、堆肥、废物、砂","test_object_cs":"Zeminy, půdy, kaly, sedimenty, komposty, odpady, písky","methodology":"Oznaczanie wielopierścieniowych węglowodorów aromatycznych metodą HPLC/FluD/DAD i obliczanie sumy WWA","methodology_en":"Determination of polycyclic aromatic hydrocarbons by HPLC/FluD/DAD and calculation of the sum of PAH","methodology_zh":"HPLC/FluD/DAD法测定多环芳烃及多环芳烃总和计算","methodology_cs":"Stanovení polycyklických aromatických uhlovodíků metodou HPLC/FluD/DAD a dopočet sumy PAU","parameters":[{"name":"antracen","range":""},{"name":"benzo(a)antracen","range":""},{"name":"benzo(a)piren","range":""},{"name":"benzo(b)fluoranten","range":""},{"name":"benzo(g,h,i)perylen","range":""},{"name":"benzo(k)fluoranten","range":""},{"name":"chryzen","range":""},{"name":"fluoranten","range":""},{"name":"indeno(1,2,3-cd)piren","range":""},{"name":"fenantren","range":""},{"name":"piren","range":""},{"name":"naftalen","range":""},{"name":"acenaftylen","range":""},{"name":"acenaften","range":""},{"name":"fluoren","range":""},{"name":"dibenzo(a,h)antracen","range":""}],"parameters_en":[{"name":"anthracene","range":""},{"name":"benzo(a)anthracene","range":""},{"name":"benzo(a)pyrene","range":""},{"name":"benzo(b)fluoranthene","range":""},{"name":"benzo(g,h,i)perylene","range":""},{"name":"benzo(k)fluoranthene","range":""},{"name":"chrysene","range":""},{"name":"fluoranthene","range":""},{"name":"indeno(1,2,3-cd)pyrene","range":""},{"name":"phenanthrene","range":""},{"name":"pyrene","range":""},{"name":"naphthalene","range":""},{"name":"acenaphthylene","range":""},{"name":"acenaphthene","range":""},{"name":"fluorene","range":""},{"name":"dibenzo(a,h)anthracene","range":""}],"parameters_zh":[{"name":"蒽","range":""},{"name":"苯并(a)蒽","range":""},{"name":"苯并(a)芘","range":""},{"name":"苯并(b)荧蒽","range":""},{"name":"苯并(g,h,i)苝","range":""},{"name":"苯并(k)荧蒽","range":""},{"name":"䓛","range":""},{"name":"荧蒽","range":""},{"name":"茚并(1,2,3-cd)芘","range":""},{"name":"菲","range":""},{"name":"芘","range":""},{"name":"萘","range":""},{"name":"苊烯","range":""},{"name":"苊","range":""},{"name":"芴","range":""},{"name":"二苯并(a,h)蒽","range":""}],"parameters_cs":[{"name":"antracen","range":""},{"name":"benzo(a)antracen","range":""},{"name":"benzo(a)pyren","range":""},{"name":"benzo(b)fluoranthen","range":""},{"name":"benzo(g,h,i)perylen","range":""},{"name":"benzo(k)fluoranthen","range":""},{"name":"chrysen","range":""},{"name":"fluoranthen","range":""},{"name":"indeno(1,2,3-cd)pyren","range":""},{"name":"fenanthren","range":""},{"name":"pyren","range":""},{"name":"naftalen","range":""},{"name":"acenaftylen","range":""},{"name":"acenaften","range":""},{"name":"fluoren","range":""},{"name":"dibenzo(a,h)antracen","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie wielopierścieniowych węglowodorów aromatycznych metodą HPLC/FluD/DAD i obliczanie sumy WWA\nZakres:\nantracen\nbenzo(a)antracen\nbenzo(a)piren\nbenzo(b)fluoranten\nbenzo(g,h,i)perylen\nbenzo(k)fluoranten\nchryzen\nfluoranten\nindeno(1,2,3-cd)piren\nfenantren\npiren\nnaftalen\nacenaftylen\nacenaften\nfluoren\ndibenzo(a,h)antracen","reference":"ZP 075b (ČSN EN ISO 17993; ČSN EN 17503)","norm_bases":["ZP 075b","ČSN EN ISO 17993","ČSN EN 17503"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Grunty, gleby, osady, osady denne, komposty, odpady, piaski Oznaczanie wielopierścieniowych węglowodorów aromatycznych metodą HPLC/FluD/DAD i obliczanie sumy WWA antracen  benzo(a)antracen  benzo(a)piren  benzo(b)fluoranten  benzo(g,h,i)perylen  benzo(k)fluoranten  chryzen  fluoranten  indeno(1,2,3-cd)piren  fenantren  piren  naftalen  acenaftylen  acenaften  fluoren  dibenzo(a,h)antracen  Zeminy, půdy, kaly, sedimenty, komposty, odpady, písky Stanovení polycyklických aromatických uhlovodíků metodou HPLC/FluD/DAD a dopočet sumy PAU antracen  benzo(a)antracen  benzo(a)pyren  benzo(b)fluoranthen  benzo(g,h,i)perylen  benzo(k)fluoranthen  chrysen  fluoranthen  indeno(1,2,3-cd)pyren  fenanthren  pyren  naftalen  acenaftylen  acenaften  fluoren  dibenzo(a,h)antracen  ZP 075b (ČSN EN ISO 17993; ČSN EN 17503) Grunty, gleby, osady, osady denne, komposty, odpady, piaski Oznaczanie wielopierscieniowych weglowodorow aromatycznych metoda HPLC/FluD/DAD i obliczanie sumy WWA antracen  benzo(a)antracen  benzo(a)piren  benzo(b)fluoranten  benzo(g,h,i)perylen  benzo(k)fluoranten  chryzen  fluoranten  indeno(1,2,3-cd)piren  fenantren  piren  naftalen  acenaftylen  acenaften  fluoren  dibenzo(a,h)antracen  Zeminy, pudy, kaly, sedimenty, komposty, odpady, pisky Stanoveni polycyklickych aromatickych uhlovodiku metodou HPLC/FluD/DAD a dopocet sumy PAU antracen  benzo(a)antracen  benzo(a)pyren  benzo(b)fluoranthen  benzo(g,h,i)perylen  benzo(k)fluoranthen  chrysen  fluoranthen  indeno(1,2,3-cd)pyren  fenanthren  pyren  naftalen  acenaftylen  acenaften  fluoren  dibenzo(a,h)antracen  ZP 075b (CSN EN ISO 17993; CSN EN 17503)","search_en":"Earths, soils, sludge, sediments, composts, waste, sands Determination of polycyclic aromatic hydrocarbons by HPLC/FluD/DAD and calculation of the sum of PAH anthracene  benzo(a)anthracene  benzo(a)pyrene  benzo(b)fluoranthene  benzo(g,h,i)perylene  benzo(k)fluoranthene  chrysene  fluoranthene  indeno(1,2,3-cd)pyrene  phenanthrene  pyrene  naphthalene  acenaphthylene  acenaphthene  fluorene  dibenzo(a,h)anthracene  ZP 075b (ČSN EN ISO 17993; ČSN EN 17503)","search_zh":"土、土壤、污泥、沉积物、堆肥、废物、砂 HPLC/FluD/DAD法测定多环芳烃及多环芳烃总和计算 蒽  苯并(a)蒽  苯并(a)芘  苯并(b)荧蒽  苯并(g,h,i)苝  苯并(k)荧蒽  䓛  荧蒽  茚并(1,2,3-cd)芘  菲  芘  萘  苊烯  苊  芴  二苯并(a,h)蒽  ZP 075b (ČSN EN ISO 17993; ČSN EN 17503)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":58,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"166e25a23f21d314a0ae79e0","lab_id":"69ad52a4de79e566650fd33a","country":"CZ","accr_number":"1277","accr_body":"ČIA","row_label":"65","test_object":"Wody: przeznaczone do spożycia, butelkowane, surowe, uzdatnione, ciepłe, podziemne, powierzchniowe, w kąpieliskach i do celów leczniczych, technologiczne i przemysłowe, ścieki, wyciąg wodny","test_object_en":"Drinking, bottled, raw, treated, hot, ground, surface, bathing and therapeutic, process and industrial, waste water, aqueous leachate","test_object_zh":"饮用水、瓶装水、原水、成品水、热水、地下水、地表水、游泳/浴用和医疗用水、工艺和工业用水、废水、水浸出液","test_object_cs":"Vody pitné, balené, surové, vyrobené, teplé, podzemní, povrchové, ke koupání a léčebným účelům, technologické a průmyslové, odpadní, vodný výluh","methodology":"Oznaczanie ogólnego węgla organicznego (OWO) i rozpuszczonego węgla organicznego (RWO) metodą katalitycznego spalania z detekcją w podczerwieni oraz obliczanie parametru „różnica TOC”","methodology_en":"Determination of total organic carbon (TOC) and dissolved organic carbon (DOC) by catalytic combustion with IR detection and calculation of the TOC difference parameter","methodology_zh":"催化燃烧红外检测法测定总有机碳（TOC）和溶解性有机碳（DOC）及TOC差值计算","methodology_cs":"Stanovení celkového organického uhlíku (TOC) a rozpuštěného organického uhlíku (DOC) katalytickým spalováním s detekcí v IČ oblasti a dopočet parametru TOC rozdíl","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie ogólnego węgla organicznego (OWO) i rozpuszczonego węgla organicznego (RWO) metodą katalitycznego spalania z detekcją w podczerwieni oraz obliczanie parametru „różnica TOC”","reference":"ZP 094 (ČSN EN 1484; ČSN EN ISO 20236)","norm_bases":["ZP 094","ČSN EN 1484","ČSN EN ISO 20236"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"różnica TOC – wartość TOC w basenie po odjęciu wartości TOC w wodzie napełniającej","note_en":"TOC difference – TOC value in the pool after subtracting the TOC value of the filling water","note_zh":"TOC差值–泳池TOC值减去补充水TOC值","note_cs":"TOC rozdíl - hodnota TOC v bazénu po odečtení hodnoty TOC v plnící vodě","search_text":"Wody: przeznaczone do spożycia, butelkowane, surowe, uzdatnione, ciepłe, podziemne, powierzchniowe, w kąpieliskach i do celów leczniczych, technologiczne i przemysłowe, ścieki, wyciąg wodny Oznaczanie ogólnego węgla organicznego (OWO) i rozpuszczonego węgla organicznego (RWO) metodą katalitycznego spalania z detekcją w podczerwieni oraz obliczanie parametru „różnica TOC” Vody pitné, balené, surové, vyrobené, teplé, podzemní, povrchové, ke koupání a léčebným účelům, technologické a průmyslové, odpadní, vodný výluh Stanovení celkového organického uhlíku (TOC) a rozpuštěného organického uhlíku (DOC) katalytickým spalováním s detekcí v IČ oblasti a dopočet parametru TOC rozdíl ZP 094 (ČSN EN 1484; ČSN EN ISO 20236) Wody: przeznaczone do spozycia, butelkowane, surowe, uzdatnione, cieple, podziemne, powierzchniowe, w kapieliskach i do celow leczniczych, technologiczne i przemyslowe, scieki, wyciag wodny Oznaczanie ogolnego wegla organicznego (OWO) i rozpuszczonego wegla organicznego (RWO) metoda katalitycznego spalania z detekcja w podczerwieni oraz obliczanie parametru „roznica TOC” Vody pitne, balene, surove, vyrobene, teple, podzemni, povrchove, ke koupani a lecebnym ucelum, technologicke a prumyslove, odpadni, vodny vyluh Stanoveni celkoveho organickeho uhliku (TOC) a rozpusteneho organickeho uhliku (DOC) katalytickym spalovanim s detekci v IC oblasti a dopocet parametru TOC rozdil ZP 094 (CSN EN 1484; CSN EN ISO 20236)","search_en":"Drinking, bottled, raw, treated, hot, ground, surface, bathing and therapeutic, process and industrial, waste water, aqueous leachate Determination of total organic carbon (TOC) and dissolved organic carbon (DOC) by catalytic combustion with IR detection and calculation of the TOC difference parameter ZP 094 (ČSN EN 1484; ČSN EN ISO 20236)","search_zh":"饮用水、瓶装水、原水、成品水、热水、地下水、地表水、游泳/浴用和医疗用水、工艺和工业用水、废水、水浸出液 催化燃烧红外检测法测定总有机碳（TOC）和溶解性有机碳（DOC）及TOC差值计算 ZP 094 (ČSN EN 1484; ČSN EN ISO 20236)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":59,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"28f479124260447e3716218e","lab_id":"69ad52a4de79e566650fd33a","country":"CZ","accr_number":"1277","accr_body":"ČIA","row_label":"66","test_object":"Wody: przeznaczone do spożycia, butelkowane, surowe, uzdatnione, ciepłe, podziemne, powierzchniowe, w kąpieliskach i do celów leczniczych, technologiczne i przemysłowe, ścieki","test_object_en":"Drinking, bottled, raw, treated, hot, ground, surface, bathing and therapeutic, process and industrial, waste water","test_object_zh":"饮用水、瓶装水、原水、成品水、热水、地下水、地表水、游泳/浴用和医疗用水、工艺和工业用水、废水","test_object_cs":"Vody pitné, balené, surové, vyrobené, teplé, podzemní, povrchové, ke koupání a léčebným účelům, technologické a průmyslové, odpadní","methodology":"Oznaczanie azotu związanego (TNb) po utlenieniu do tlenków azotu z detekcją chemiluminescencyjną oraz obliczanie azotu nieorganicznego i organicznego","methodology_en":"Determination of total bound nitrogen (TNb) after oxidation to nitrogen oxides with chemiluminescence detection and calculation of inorganic and organic nitrogen","methodology_zh":"氧化为氮氧化物后化学发光检测法测定总结合氮（TNb）及无机氮和有机氮计算","methodology_cs":"Stanovení vázaného dusíku (TNb) po oxidaci na oxidy dusíku s chemiluminiscenční detekcí a dopočet anorganického a organického dusíku","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie azotu związanego (TNb) po utlenieniu do tlenków azotu z detekcją chemiluminescencyjną oraz obliczanie azotu nieorganicznego i organicznego","reference":"ZP 095 (ČSN EN ISO 20236)","norm_bases":["ZP 095","ČSN EN ISO 20236"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody: przeznaczone do spożycia, butelkowane, surowe, uzdatnione, ciepłe, podziemne, powierzchniowe, w kąpieliskach i do celów leczniczych, technologiczne i przemysłowe, ścieki Oznaczanie azotu związanego (TNb) po utlenieniu do tlenków azotu z detekcją chemiluminescencyjną oraz obliczanie azotu nieorganicznego i organicznego Vody pitné, balené, surové, vyrobené, teplé, podzemní, povrchové, ke koupání a léčebným účelům, technologické a průmyslové, odpadní Stanovení vázaného dusíku (TNb) po oxidaci na oxidy dusíku s chemiluminiscenční detekcí a dopočet anorganického a organického dusíku ZP 095 (ČSN EN ISO 20236) Wody: przeznaczone do spozycia, butelkowane, surowe, uzdatnione, cieple, podziemne, powierzchniowe, w kapieliskach i do celow leczniczych, technologiczne i przemyslowe, scieki Oznaczanie azotu zwiazanego (TNb) po utlenieniu do tlenkow azotu z detekcja chemiluminescencyjna oraz obliczanie azotu nieorganicznego i organicznego Vody pitne, balene, surove, vyrobene, teple, podzemni, povrchove, ke koupani a lecebnym ucelum, technologicke a prumyslove, odpadni Stanoveni vazaneho dusiku (TNb) po oxidaci na oxidy dusiku s chemiluminiscencni detekci a dopocet anorganickeho a organickeho dusiku ZP 095 (CSN EN ISO 20236)","search_en":"Drinking, bottled, raw, treated, hot, ground, surface, bathing and therapeutic, process and industrial, waste water Determination of total bound nitrogen (TNb) after oxidation to nitrogen oxides with chemiluminescence detection and calculation of inorganic and organic nitrogen ZP 095 (ČSN EN ISO 20236)","search_zh":"饮用水、瓶装水、原水、成品水、热水、地下水、地表水、游泳/浴用和医疗用水、工艺和工业用水、废水 氧化为氮氧化物后化学发光检测法测定总结合氮（TNb）及无机氮和有机氮计算 ZP 095 (ČSN EN ISO 20236)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":60,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"82e30646deb930ce31077697","lab_id":"69ad52a4de79e566650fd33a","country":"CZ","accr_number":"1277","accr_body":"ČIA","row_label":"67","test_object":"Wody: przeznaczone do spożycia, butelkowane, surowe, uzdatnione, ciepłe, podziemne, powierzchniowe, w kąpieliskach i do celów leczniczych, technologiczne i przemysłowe, ścieki, wyciąg wodny, roztwory absorpcyjne i sorbenty stałe (emisje, powietrze wewnętrzne i na stanowiskach pracy)","test_object_en":"Drinking, bottled, raw, treated, hot, ground, surface, bathing and therapeutic, process and industrial, waste water, aqueous leachate, absorption solutions and solid sorbents (emissions, indoor and workplace air)","test_object_zh":"饮用水、瓶装水、原水、成品水、热水、地下水、地表水、游泳/浴用和医疗用水、工艺和工业用水、废水、水浸出液、吸收液和固体吸附剂（排放、室内和工作场所空气）","test_object_cs":"Vody pitné, balené, surové, vyrobené, teplé, podzemní, povrchové, ke koupání a léčebným účelům, technologické a průmyslové, odpadní, vodný výluh, absorpční roztoky a pevné sorbenty (emise, vnitřní a pracovní ovzduší)","methodology":"Oznaczanie rozpuszczonych anionów metodą IC, obliczanie sumy azotynów i azotanów, całkowitej zawartości kwasów oraz parametru „różnica azotanów”","methodology_en":"Determination of dissolved anions by IC, calculation of the sum of nitrites and nitrates, total acid content and of the nitrate difference parameter","methodology_zh":"离子色谱法测定溶解性阴离子，计算亚硝酸盐和硝酸盐之和、总酸含量及硝酸盐差值","methodology_cs":"Stanovení rozpuštěných aniontů metodou IC, dopočet součtu dusitanů a dusičnanů, celkového obsahu kyselin a dopočet parametru dusičnany rozdíl","parameters":[{"name":"bromiany","range":""},{"name":"fluorki","range":""},{"name":"chlorki","range":""},{"name":"azotyny","range":""},{"name":"azotany","range":""},{"name":"fosforany","range":""},{"name":"siarczany","range":""},{"name":"azot azotynowy","range":""},{"name":"azot azotanowy","range":""},{"name":"chloryny","range":""},{"name":"chlorany","range":""}],"parameters_en":[{"name":"bromates","range":""},{"name":"fluorides","range":""},{"name":"chlorides","range":""},{"name":"nitrites","range":""},{"name":"nitrates","range":""},{"name":"phosphates","range":""},{"name":"sulphates","range":""},{"name":"nitrite nitrogen","range":""},{"name":"nitrate nitrogen","range":""},{"name":"chlorites","range":""},{"name":"chlorates","range":""}],"parameters_zh":[{"name":"溴酸盐","range":""},{"name":"氟化物","range":""},{"name":"氯化物","range":""},{"name":"亚硝酸盐","range":""},{"name":"硝酸盐","range":""},{"name":"磷酸盐","range":""},{"name":"硫酸盐","range":""},{"name":"亚硝酸盐氮","range":""},{"name":"硝酸盐氮","range":""},{"name":"亚氯酸盐","range":""},{"name":"氯酸盐","range":""}],"parameters_cs":[{"name":"bromičnany","range":""},{"name":"fluoridy","range":""},{"name":"chloridy","range":""},{"name":"dusitany","range":""},{"name":"dusičnany","range":""},{"name":"fosforečnany","range":""},{"name":"sírany","range":""},{"name":"dusík dusitanový","range":""},{"name":"dusík dusičnanový","range":""},{"name":"chloritany","range":""},{"name":"chlorečnany","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie rozpuszczonych anionów metodą IC, obliczanie sumy azotynów i azotanów, całkowitej zawartości kwasów oraz parametru „różnica azotanów”\nZakres:\nbromiany\nfluorki\nchlorki\nazotyny\nazotany\nfosforany\nsiarczany\nazot azotynowy\nazot azotanowy\nchloryny\nchlorany","reference":"ZP 100 (ČSN EN ISO 10304-1; ČSN EN ISO 10304-4; ČSN EN ISO 15061)","norm_bases":["ZP 100","ČSN EN ISO 10304-1","ČSN EN ISO 10304-4","ČSN EN ISO 15061"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"różnica azotanów – wartość azotanów w basenie po odjęciu wartości azotanów w wodzie napełniającej","note_en":"nitrate difference – nitrate value in the pool after subtracting the nitrate value of the filling water","note_zh":"硝酸盐差值–泳池硝酸盐值减去补充水硝酸盐值","note_cs":"dusičnany rozdíl - hodnota dusičnanů v bazénu po odečtení hodnoty dusičnanů v plnící vodě","search_text":"Wody: przeznaczone do spożycia, butelkowane, surowe, uzdatnione, ciepłe, podziemne, powierzchniowe, w kąpieliskach i do celów leczniczych, technologiczne i przemysłowe, ścieki, wyciąg wodny, roztwory absorpcyjne i sorbenty stałe (emisje, powietrze wewnętrzne i na stanowiskach pracy) Oznaczanie rozpuszczonych anionów metodą IC, obliczanie sumy azotynów i azotanów, całkowitej zawartości kwasów oraz parametru „różnica azotanów” bromiany  fluorki  chlorki  azotyny  azotany  fosforany  siarczany  azot azotynowy  azot azotanowy  chloryny  chlorany  Vody pitné, balené, surové, vyrobené, teplé, podzemní, povrchové, ke koupání a léčebným účelům, technologické a průmyslové, odpadní, vodný výluh, absorpční roztoky a pevné sorbenty (emise, vnitřní a pracovní ovzduší) Stanovení rozpuštěných aniontů metodou IC, dopočet součtu dusitanů a dusičnanů, celkového obsahu kyselin a dopočet parametru dusičnany rozdíl bromičnany  fluoridy  chloridy  dusitany  dusičnany  fosforečnany  sírany  dusík dusitanový  dusík dusičnanový  chloritany  chlorečnany  ZP 100 (ČSN EN ISO 10304-1; ČSN EN ISO 10304-4; ČSN EN ISO 15061) Wody: przeznaczone do spozycia, butelkowane, surowe, uzdatnione, cieple, podziemne, powierzchniowe, w kapieliskach i do celow leczniczych, technologiczne i przemyslowe, scieki, wyciag wodny, roztwory absorpcyjne i sorbenty stale (emisje, powietrze wewnetrzne i na stanowiskach pracy) Oznaczanie rozpuszczonych anionow metoda IC, obliczanie sumy azotynow i azotanow, calkowitej zawartosci kwasow oraz parametru „roznica azotanow” bromiany  fluorki  chlorki  azotyny  azotany  fosforany  siarczany  azot azotynowy  azot azotanowy  chloryny  chlorany  Vody pitne, balene, surove, vyrobene, teple, podzemni, povrchove, ke koupani a lecebnym ucelum, technologicke a prumyslove, odpadni, vodny vyluh, absorpcni roztoky a pevne sorbenty (emise, vnitrni a pracovni ovzdusi) Stanoveni rozpustenych aniontu metodou IC, dopocet souctu dusitanu a dusicnanu, celkoveho obsahu kyselin a dopocet parametru dusicnany rozdil bromicnany  fluoridy  chloridy  dusitany  dusicnany  fosforecnany  sirany  dusik dusitanovy  dusik dusicnanovy  chloritany  chlorecnany  ZP 100 (CSN EN ISO 10304-1; CSN EN ISO 10304-4; CSN EN ISO 15061)","search_en":"Drinking, bottled, raw, treated, hot, ground, surface, bathing and therapeutic, process and industrial, waste water, aqueous leachate, absorption solutions and solid sorbents (emissions, indoor and workplace air) Determination of dissolved anions by IC, calculation of the sum of nitrites and nitrates, total acid content and of the nitrate difference parameter bromates  fluorides  chlorides  nitrites  nitrates  phosphates  sulphates  nitrite nitrogen  nitrate nitrogen  chlorites  chlorates  ZP 100 (ČSN EN ISO 10304-1; ČSN EN ISO 10304-4; ČSN EN ISO 15061)","search_zh":"饮用水、瓶装水、原水、成品水、热水、地下水、地表水、游泳/浴用和医疗用水、工艺和工业用水、废水、水浸出液、吸收液和固体吸附剂（排放、室内和工作场所空气） 离子色谱法测定溶解性阴离子，计算亚硝酸盐和硝酸盐之和、总酸含量及硝酸盐差值 溴酸盐  氟化物  氯化物  亚硝酸盐  硝酸盐  磷酸盐  硫酸盐  亚硝酸盐氮  硝酸盐氮  亚氯酸盐  氯酸盐  ZP 100 (ČSN EN ISO 10304-1; ČSN EN ISO 10304-4; ČSN EN ISO 15061)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":61,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"41088e0ce433bb2e5f607782","lab_id":"69ad52a4de79e566650fd33a","country":"CZ","accr_number":"1277","accr_body":"ČIA","row_label":"68","test_object":"Wody: przeznaczone do spożycia, butelkowane, surowe, uzdatnione, ciepłe, podziemne, powierzchniowe, w kąpieliskach i do celów leczniczych, technologiczne i przemysłowe, ścieki, wyciąg wodny, roztwory absorpcyjne (emisje, powietrze wewnętrzne i na stanowiskach pracy)","test_object_en":"Drinking, bottled, raw, treated, hot, ground, surface, bathing and therapeutic, process and industrial, waste water, aqueous leachate, absorption solutions (emissions, indoor and workplace air)","test_object_zh":"饮用水、瓶装水、原水、成品水、热水、地下水、地表水、游泳/浴用和医疗用水、工艺和工业用水、废水、水浸出液、吸收液（排放、室内和工作场所空气）","test_object_cs":"Vody pitné, balené, surové, vyrobené, teplé, podzemní, povrchové, ke koupání a léčebným účelům, technologické a průmyslové, odpadní, vodný výluh, absorpční roztoky (emise, vnitřní a pracovní ovzduší)","methodology":"Oznaczanie rozpuszczonych kationów metodą IC i obliczanie sumy wapnia i magnezu, twardości ogólnej i wolnego amoniaku","methodology_en":"Determination of dissolved cations by IC and calculation of the sum of calcium and magnesium, total hardness and free ammonia","methodology_zh":"离子色谱法测定溶解性阳离子及钙镁总和、总硬度和游离氨计算","methodology_cs":"Stanovení rozpuštěných kationtů metodou IC a dopočet sumy vápníku a hořčíku, celkové tvrdosti a volného amoniaku","parameters":[{"name":"Lit (Li+)","range":""},{"name":"Sód (Na+)","range":""},{"name":"Amon (NH4+)","range":""},{"name":"Potas (K+)","range":""},{"name":"Wapń (Ca2+)","range":""},{"name":"Magnez (Mg2+)","range":""},{"name":"Azot amonowy (N-NH4+)","range":""}],"parameters_en":[{"name":"Lithium (Li+)","range":""},{"name":"Sodium (Na+)","range":""},{"name":"Ammonium (NH4+)","range":""},{"name":"Potassium (K+)","range":""},{"name":"Calcium (Ca2+)","range":""},{"name":"Magnesium (Mg2+)","range":""},{"name":"Ammonium nitrogen (N-NH4+)","range":""}],"parameters_zh":[{"name":"锂离子（Li+）","range":""},{"name":"钠离子（Na+）","range":""},{"name":"铵离子（NH4+）","range":""},{"name":"钾离子（K+）","range":""},{"name":"钙离子（Ca2+）","range":""},{"name":"镁离子（Mg2+）","range":""},{"name":"铵态氮（N-NH4+）","range":""}],"parameters_cs":[{"name":"Li+","range":""},{"name":"Na+","range":""},{"name":"NH4+","range":""},{"name":"K+","range":""},{"name":"Ca2+","range":""},{"name":"Mg2+","range":""},{"name":"N-NH4+","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":["suma Ca+Mg"],"computed_en":["sum Ca+Mg"],"computed_zh":["钙镁总和"],"computed_cs":["suma Ca+Mg"],"activity":"Oznaczanie rozpuszczonych kationów metodą IC i obliczanie sumy wapnia i magnezu, twardości ogólnej i wolnego amoniaku\nZakres:\nLit (Li+)\nSód (Na+)\nAmon (NH4+)\nPotas (K+)\nWapń (Ca2+)\nMagnez (Mg2+)\nAzot amonowy (N-NH4+)","reference":"ZP 101 (ČSN EN ISO 14911)","norm_bases":["ZP 101","ČSN EN ISO 14911"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody: przeznaczone do spożycia, butelkowane, surowe, uzdatnione, ciepłe, podziemne, powierzchniowe, w kąpieliskach i do celów leczniczych, technologiczne i przemysłowe, ścieki, wyciąg wodny, roztwory absorpcyjne (emisje, powietrze wewnętrzne i na stanowiskach pracy) Oznaczanie rozpuszczonych kationów metodą IC i obliczanie sumy wapnia i magnezu, twardości ogólnej i wolnego amoniaku Lit (Li+)  Sód (Na+)  Amon (NH4+)  Potas (K+)  Wapń (Ca2+)  Magnez (Mg2+)  Azot amonowy (N-NH4+)  suma Ca+Mg Vody pitné, balené, surové, vyrobené, teplé, podzemní, povrchové, ke koupání a léčebným účelům, technologické a průmyslové, odpadní, vodný výluh, absorpční roztoky (emise, vnitřní a pracovní ovzduší) Stanovení rozpuštěných kationtů metodou IC a dopočet sumy vápníku a hořčíku, celkové tvrdosti a volného amoniaku Li+  Na+  NH4+  K+  Ca2+  Mg2+  N-NH4+  suma Ca+Mg ZP 101 (ČSN EN ISO 14911) Wody: przeznaczone do spozycia, butelkowane, surowe, uzdatnione, cieple, podziemne, powierzchniowe, w kapieliskach i do celow leczniczych, technologiczne i przemyslowe, scieki, wyciag wodny, roztwory absorpcyjne (emisje, powietrze wewnetrzne i na stanowiskach pracy) Oznaczanie rozpuszczonych kationow metoda IC i obliczanie sumy wapnia i magnezu, twardosci ogolnej i wolnego amoniaku Lit (Li+)  Sod (Na+)  Amon (NH4+)  Potas (K+)  Wapn (Ca2+)  Magnez (Mg2+)  Azot amonowy (N-NH4+)  suma Ca+Mg Vody pitne, balene, surove, vyrobene, teple, podzemni, povrchove, ke koupani a lecebnym ucelum, technologicke a prumyslove, odpadni, vodny vyluh, absorpcni roztoky (emise, vnitrni a pracovni ovzdusi) Stanoveni rozpustenych kationtu metodou IC a dopocet sumy vapniku a horciku, celkove tvrdosti a volneho amoniaku Li+  Na+  NH4+  K+  Ca2+  Mg2+  N-NH4+  suma Ca+Mg ZP 101 (CSN EN ISO 14911)","search_en":"Drinking, bottled, raw, treated, hot, ground, surface, bathing and therapeutic, process and industrial, waste water, aqueous leachate, absorption solutions (emissions, indoor and workplace air) Determination of dissolved cations by IC and calculation of the sum of calcium and magnesium, total hardness and free ammonia Lithium (Li+)  Sodium (Na+)  Ammonium (NH4+)  Potassium (K+)  Calcium (Ca2+)  Magnesium (Mg2+)  Ammonium nitrogen (N-NH4+)  sum Ca+Mg ZP 101 (ČSN EN ISO 14911)","search_zh":"饮用水、瓶装水、原水、成品水、热水、地下水、地表水、游泳/浴用和医疗用水、工艺和工业用水、废水、水浸出液、吸收液（排放、室内和工作场所空气） 离子色谱法测定溶解性阳离子及钙镁总和、总硬度和游离氨计算 锂离子（Li+）  钠离子（Na+）  铵离子（NH4+）  钾离子（K+）  钙离子（Ca2+）  镁离子（Mg2+）  铵态氮（N-NH4+）  钙镁总和 ZP 101 (ČSN EN ISO 14911)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":62,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"cce01cbe4dd25f91a282b16e","lab_id":"69ad52a4de79e566650fd33a","country":"CZ","accr_number":"1277","accr_body":"ČIA","row_label":"69","test_object":"Wody: przeznaczone do spożycia, butelkowane, surowe, uzdatnione, ciepłe, podziemne, powierzchniowe, w kąpieliskach i do celów leczniczych, technologiczne i przemysłowe, ścieki, wyciąg wodny, roztwory absorpcyjne (emisje, powietrze wewnętrzne i na stanowiskach pracy)","test_object_en":"Drinking, bottled, raw, treated, hot, ground, surface, bathing and therapeutic, process and industrial, waste water, aqueous leachate, absorption solutions (emissions, indoor and workplace air)","test_object_zh":"饮用水、瓶装水、原水、成品水、热水、地下水、地表水、游泳/浴用和医疗用水、工艺和工业用水、废水、水浸出液、吸收液（排放、室内和工作场所空气）","test_object_cs":"Vody pitné, balené, surové, vyrobené, teplé, podzemní, povrchové, ke koupání a léčebným účelům, technologické a průmyslové, odpadní, vodný výluh, absorpční roztoky (emise, vnitřní a pracovní ovzduší)","methodology":"Oznaczanie pierwiastków metodą ICP/MS","methodology_en":"Determination of elements by ICP/MS","methodology_zh":"ICP/MS法测定元素","methodology_cs":"Stanovení prvků metodou ICP/MS","parameters":[{"name":"Srebro (Ag)","range":""},{"name":"Glin (Al)","range":""},{"name":"Arsen (As)","range":""},{"name":"Bor (B)","range":""},{"name":"Bar (Ba)","range":""},{"name":"Beryl (Be)","range":""},{"name":"Wapń (Ca)","range":""},{"name":"Kadm (Cd)","range":""},{"name":"Kobalt (Co)","range":""},{"name":"Chrom (Cr)","range":""},{"name":"Chrom sześciowartościowy (CrVI)","range":""},{"name":"Miedź (Cu)","range":""},{"name":"Żelazo (Fe)","range":""},{"name":"Potas (K)","range":""},{"name":"Magnez (Mg)","range":""},{"name":"Mangan (Mn)","range":""},{"name":"Molibden (Mo)","range":""},{"name":"Sód (Na)","range":""},{"name":"Nikiel (Ni)","range":""},{"name":"Fosfor (P)","range":""},{"name":"Ołów (Pb)","range":""},{"name":"Antymon (Sb)","range":""},{"name":"Selen (Se)","range":""},{"name":"Cyna (Sn)","range":""},{"name":"Tal (Tl)","range":""},{"name":"Wanad (V)","range":""},{"name":"Cynk (Zn)","range":""},{"name":"Uran (U)","range":""}],"parameters_en":[{"name":"Silver (Ag)","range":""},{"name":"Aluminium (Al)","range":""},{"name":"Arsenic (As)","range":""},{"name":"Boron (B)","range":""},{"name":"Barium (Ba)","range":""},{"name":"Beryllium (Be)","range":""},{"name":"Calcium (Ca)","range":""},{"name":"Cadmium (Cd)","range":""},{"name":"Cobalt (Co)","range":""},{"name":"Chromium (Cr)","range":""},{"name":"Hexavalent chromium (CrVI)","range":""},{"name":"Copper (Cu)","range":""},{"name":"Iron (Fe)","range":""},{"name":"Potassium (K)","range":""},{"name":"Magnesium (Mg)","range":""},{"name":"Manganese (Mn)","range":""},{"name":"Molybdenum (Mo)","range":""},{"name":"Sodium (Na)","range":""},{"name":"Nickel (Ni)","range":""},{"name":"Phosphorus (P)","range":""},{"name":"Lead (Pb)","range":""},{"name":"Antimony (Sb)","range":""},{"name":"Selenium (Se)","range":""},{"name":"Tin (Sn)","range":""},{"name":"Thallium (Tl)","range":""},{"name":"Vanadium (V)","range":""},{"name":"Zinc (Zn)","range":""},{"name":"Uranium (U)","range":""}],"parameters_zh":[{"name":"银（Ag）","range":""},{"name":"铝（Al）","range":""},{"name":"砷（As）","range":""},{"name":"硼（B）","range":""},{"name":"钡（Ba）","range":""},{"name":"铍（Be）","range":""},{"name":"钙（Ca）","range":""},{"name":"镉（Cd）","range":""},{"name":"钴（Co）","range":""},{"name":"铬（Cr）","range":""},{"name":"六价铬（CrVI）","range":""},{"name":"铜（Cu）","range":""},{"name":"铁（Fe）","range":""},{"name":"钾（K）","range":""},{"name":"镁（Mg）","range":""},{"name":"锰（Mn）","range":""},{"name":"钼（Mo）","range":""},{"name":"钠（Na）","range":""},{"name":"镍（Ni）","range":""},{"name":"磷（P）","range":""},{"name":"铅（Pb）","range":""},{"name":"锑（Sb）","range":""},{"name":"硒（Se）","range":""},{"name":"锡（Sn）","range":""},{"name":"铊（Tl）","range":""},{"name":"钒（V）","range":""},{"name":"锌（Zn）","range":""},{"name":"铀（U）","range":""}],"parameters_cs":[{"name":"Ag","range":""},{"name":"Al","range":""},{"name":"As","range":""},{"name":"B","range":""},{"name":"Ba","range":""},{"name":"Be","range":""},{"name":"Ca","range":""},{"name":"Cd","range":""},{"name":"Co","range":""},{"name":"Cr","range":""},{"name":"CrVI","range":""},{"name":"Cu","range":""},{"name":"Fe","range":""},{"name":"K","range":""},{"name":"Mg","range":""},{"name":"Mn","range":""},{"name":"Mo","range":""},{"name":"Na","range":""},{"name":"Ni","range":""},{"name":"P","range":""},{"name":"Pb","range":""},{"name":"Sb","range":""},{"name":"Se","range":""},{"name":"Sn","range":""},{"name":"Tl","range":""},{"name":"V","range":""},{"name":"Zn","range":""},{"name":"U","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie pierwiastków metodą ICP/MS\nZakres:\nSrebro (Ag)\nGlin (Al)\nArsen (As)\nBor (B)\nBar (Ba)\nBeryl (Be)\nWapń (Ca)\nKadm (Cd)\nKobalt (Co)\nChrom (Cr)\nChrom sześciowartościowy (CrVI)\nMiedź (Cu)\nŻelazo (Fe)\nPotas (K)\nMagnez (Mg)\nMangan (Mn)\nMolibden (Mo)\nSód (Na)\nNikiel (Ni)\nFosfor (P)\nOłów (Pb)\nAntymon (Sb)\nSelen (Se)\nCyna (Sn)\nTal (Tl)\nWanad (V)\nCynk (Zn)\nUran (U)","reference":"ZP 102a (ČSN EN ISO 17294-2; ČSN EN ISO 15587-2)","norm_bases":["ZP 102a","ČSN EN ISO 17294-2","ČSN EN ISO 15587-2"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"noty aplikacyjne Agilent Technologies i Milestone","note_en":"Agilent Technologies and Milestone application notes","note_zh":"Agilent Technologies和Milestone应用说明","note_cs":"aplikační listy Agilent Technologies a Milestone","search_text":"Wody: przeznaczone do spożycia, butelkowane, surowe, uzdatnione, ciepłe, podziemne, powierzchniowe, w kąpieliskach i do celów leczniczych, technologiczne i przemysłowe, ścieki, wyciąg wodny, roztwory absorpcyjne (emisje, powietrze wewnętrzne i na stanowiskach pracy) Oznaczanie pierwiastków metodą ICP/MS Srebro (Ag)  Glin (Al)  Arsen (As)  Bor (B)  Bar (Ba)  Beryl (Be)  Wapń (Ca)  Kadm (Cd)  Kobalt (Co)  Chrom (Cr)  Chrom sześciowartościowy (CrVI)  Miedź (Cu)  Żelazo (Fe)  Potas (K)  Magnez (Mg)  Mangan (Mn)  Molibden (Mo)  Sód (Na)  Nikiel (Ni)  Fosfor (P)  Ołów (Pb)  Antymon (Sb)  Selen (Se)  Cyna (Sn)  Tal (Tl)  Wanad (V)  Cynk (Zn)  Uran (U)  Vody pitné, balené, surové, vyrobené, teplé, podzemní, povrchové, ke koupání a léčebným účelům, technologické a průmyslové, odpadní, vodný výluh, absorpční roztoky (emise, vnitřní a pracovní ovzduší) Stanovení prvků metodou ICP/MS Ag  Al  As  B  Ba  Be  Ca  Cd  Co  Cr  CrVI  Cu  Fe  K  Mg  Mn  Mo  Na  Ni  P  Pb  Sb  Se  Sn  Tl  V  Zn  U  ZP 102a (ČSN EN ISO 17294-2; ČSN EN ISO 15587-2) Wody: przeznaczone do spozycia, butelkowane, surowe, uzdatnione, cieple, podziemne, powierzchniowe, w kapieliskach i do celow leczniczych, technologiczne i przemyslowe, scieki, wyciag wodny, roztwory absorpcyjne (emisje, powietrze wewnetrzne i na stanowiskach pracy) Oznaczanie pierwiastkow metoda ICP/MS Srebro (Ag)  Glin (Al)  Arsen (As)  Bor (B)  Bar (Ba)  Beryl (Be)  Wapn (Ca)  Kadm (Cd)  Kobalt (Co)  Chrom (Cr)  Chrom szesciowartosciowy (CrVI)  Miedz (Cu)  Zelazo (Fe)  Potas (K)  Magnez (Mg)  Mangan (Mn)  Molibden (Mo)  Sod (Na)  Nikiel (Ni)  Fosfor (P)  Olow (Pb)  Antymon (Sb)  Selen (Se)  Cyna (Sn)  Tal (Tl)  Wanad (V)  Cynk (Zn)  Uran (U)  Vody pitne, balene, surove, vyrobene, teple, podzemni, povrchove, ke koupani a lecebnym ucelum, technologicke a prumyslove, odpadni, vodny vyluh, absorpcni roztoky (emise, vnitrni a pracovni ovzdusi) Stanoveni prvku metodou ICP/MS Ag  Al  As  B  Ba  Be  Ca  Cd  Co  Cr  CrVI  Cu  Fe  K  Mg  Mn  Mo  Na  Ni  P  Pb  Sb  Se  Sn  Tl  V  Zn  U  ZP 102a (CSN EN ISO 17294-2; CSN EN ISO 15587-2)","search_en":"Drinking, bottled, raw, treated, hot, ground, surface, bathing and therapeutic, process and industrial, waste water, aqueous leachate, absorption solutions (emissions, indoor and workplace air) Determination of elements by ICP/MS Silver (Ag)  Aluminium (Al)  Arsenic (As)  Boron (B)  Barium (Ba)  Beryllium (Be)  Calcium (Ca)  Cadmium (Cd)  Cobalt (Co)  Chromium (Cr)  Hexavalent chromium (CrVI)  Copper (Cu)  Iron (Fe)  Potassium (K)  Magnesium (Mg)  Manganese (Mn)  Molybdenum (Mo)  Sodium (Na)  Nickel (Ni)  Phosphorus (P)  Lead (Pb)  Antimony (Sb)  Selenium (Se)  Tin (Sn)  Thallium (Tl)  Vanadium (V)  Zinc (Zn)  Uranium (U)  ZP 102a (ČSN EN ISO 17294-2; ČSN EN ISO 15587-2)","search_zh":"饮用水、瓶装水、原水、成品水、热水、地下水、地表水、游泳/浴用和医疗用水、工艺和工业用水、废水、水浸出液、吸收液（排放、室内和工作场所空气） ICP/MS法测定元素 银（Ag）  铝（Al）  砷（As）  硼（B）  钡（Ba）  铍（Be）  钙（Ca）  镉（Cd）  钴（Co）  铬（Cr）  六价铬（CrVI）  铜（Cu）  铁（Fe）  钾（K）  镁（Mg）  锰（Mn）  钼（Mo）  钠（Na）  镍（Ni）  磷（P）  铅（Pb）  锑（Sb）  硒（Se）  锡（Sn）  铊（Tl）  钒（V）  锌（Zn）  铀（U）  ZP 102a (ČSN EN ISO 17294-2; ČSN EN ISO 15587-2)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":63,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"0bca963f8e5fffc54f1e3531","lab_id":"69ad52a4de79e566650fd33a","country":"CZ","accr_number":"1277","accr_body":"ČIA","row_label":"70","test_object":"Grunty, gleby, osady, osady denne, komposty, odpady, piaski","test_object_en":"Earths, soils, sludge, sediments, composts, waste, sands","test_object_zh":"土、土壤、污泥、沉积物、堆肥、废物、砂","test_object_cs":"Zeminy, půdy, kaly, sedimenty, komposty, odpady, písky","methodology":"Oznaczanie pierwiastków metodą ICP/MS","methodology_en":"Determination of elements by ICP/MS","methodology_zh":"ICP/MS法测定元素","methodology_cs":"Stanovení prvků metodou ICP/MS","parameters":[{"name":"Srebro (Ag)","range":""},{"name":"Glin (Al)","range":""},{"name":"Arsen (As)","range":""},{"name":"Bar (Ba)","range":""},{"name":"Beryl (Be)","range":""},{"name":"Wapń (Ca)","range":""},{"name":"Kadm (Cd)","range":""},{"name":"Kobalt (Co)","range":""},{"name":"Chrom (Cr)","range":""},{"name":"Miedź (Cu)","range":""},{"name":"Żelazo (Fe)","range":""},{"name":"Potas (K)","range":""},{"name":"Mangan (Mn)","range":""},{"name":"Magnez (Mg)","range":""},{"name":"Nikiel (Ni)","range":""},{"name":"Fosfor (P)","range":""},{"name":"Ołów (Pb)","range":""},{"name":"Cyna (Sn)","range":""},{"name":"Wanad (V)","range":""},{"name":"Cynk (Zn)","range":""}],"parameters_en":[{"name":"Silver (Ag)","range":""},{"name":"Aluminium (Al)","range":""},{"name":"Arsenic (As)","range":""},{"name":"Barium (Ba)","range":""},{"name":"Beryllium (Be)","range":""},{"name":"Calcium (Ca)","range":""},{"name":"Cadmium (Cd)","range":""},{"name":"Cobalt (Co)","range":""},{"name":"Chromium (Cr)","range":""},{"name":"Copper (Cu)","range":""},{"name":"Iron (Fe)","range":""},{"name":"Potassium (K)","range":""},{"name":"Manganese (Mn)","range":""},{"name":"Magnesium (Mg)","range":""},{"name":"Nickel (Ni)","range":""},{"name":"Phosphorus (P)","range":""},{"name":"Lead (Pb)","range":""},{"name":"Tin (Sn)","range":""},{"name":"Vanadium (V)","range":""},{"name":"Zinc (Zn)","range":""}],"parameters_zh":[{"name":"银（Ag）","range":""},{"name":"铝（Al）","range":""},{"name":"砷（As）","range":""},{"name":"钡（Ba）","range":""},{"name":"铍（Be）","range":""},{"name":"钙（Ca）","range":""},{"name":"镉（Cd）","range":""},{"name":"钴（Co）","range":""},{"name":"铬（Cr）","range":""},{"name":"铜（Cu）","range":""},{"name":"铁（Fe）","range":""},{"name":"钾（K）","range":""},{"name":"锰（Mn）","range":""},{"name":"镁（Mg）","range":""},{"name":"镍（Ni）","range":""},{"name":"磷（P）","range":""},{"name":"铅（Pb）","range":""},{"name":"锡（Sn）","range":""},{"name":"钒（V）","range":""},{"name":"锌（Zn）","range":""}],"parameters_cs":[{"name":"Ag","range":""},{"name":"Al","range":""},{"name":"As","range":""},{"name":"Ba","range":""},{"name":"Be","range":""},{"name":"Ca","range":""},{"name":"Cd","range":""},{"name":"Co","range":""},{"name":"Cr","range":""},{"name":"Cu","range":""},{"name":"Fe","range":""},{"name":"K","range":""},{"name":"Mn","range":""},{"name":"Mg","range":""},{"name":"Ni","range":""},{"name":"P","range":""},{"name":"Pb","range":""},{"name":"Sn","range":""},{"name":"V","range":""},{"name":"Zn","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie pierwiastków metodą ICP/MS\nZakres:\nSrebro (Ag)\nGlin (Al)\nArsen (As)\nBar (Ba)\nBeryl (Be)\nWapń (Ca)\nKadm (Cd)\nKobalt (Co)\nChrom (Cr)\nMiedź (Cu)\nŻelazo (Fe)\nPotas (K)\nMangan (Mn)\nMagnez (Mg)\nNikiel (Ni)\nFosfor (P)\nOłów (Pb)\nCyna (Sn)\nWanad (V)\nCynk (Zn)","reference":"ZP 102b (ČSN EN ISO 17294-2; ČSN EN 13656; ČSN EN 16965)","norm_bases":["ZP 102b","ČSN EN ISO 17294-2","ČSN EN 13656","ČSN EN 16965"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"noty aplikacyjne Agilent Technologies i Milestone","note_en":"Agilent Technologies and Milestone application notes","note_zh":"Agilent Technologies和Milestone应用说明","note_cs":"aplikační listy Agilent Technologies a Milestone","search_text":"Grunty, gleby, osady, osady denne, komposty, odpady, piaski Oznaczanie pierwiastków metodą ICP/MS Srebro (Ag)  Glin (Al)  Arsen (As)  Bar (Ba)  Beryl (Be)  Wapń (Ca)  Kadm (Cd)  Kobalt (Co)  Chrom (Cr)  Miedź (Cu)  Żelazo (Fe)  Potas (K)  Mangan (Mn)  Magnez (Mg)  Nikiel (Ni)  Fosfor (P)  Ołów (Pb)  Cyna (Sn)  Wanad (V)  Cynk (Zn)  Zeminy, půdy, kaly, sedimenty, komposty, odpady, písky Stanovení prvků metodou ICP/MS Ag  Al  As  Ba  Be  Ca  Cd  Co  Cr  Cu  Fe  K  Mn  Mg  Ni  P  Pb  Sn  V  Zn  ZP 102b (ČSN EN ISO 17294-2; ČSN EN 13656; ČSN EN 16965) Grunty, gleby, osady, osady denne, komposty, odpady, piaski Oznaczanie pierwiastkow metoda ICP/MS Srebro (Ag)  Glin (Al)  Arsen (As)  Bar (Ba)  Beryl (Be)  Wapn (Ca)  Kadm (Cd)  Kobalt (Co)  Chrom (Cr)  Miedz (Cu)  Zelazo (Fe)  Potas (K)  Mangan (Mn)  Magnez (Mg)  Nikiel (Ni)  Fosfor (P)  Olow (Pb)  Cyna (Sn)  Wanad (V)  Cynk (Zn)  Zeminy, pudy, kaly, sedimenty, komposty, odpady, pisky Stanoveni prvku metodou ICP/MS Ag  Al  As  Ba  Be  Ca  Cd  Co  Cr  Cu  Fe  K  Mn  Mg  Ni  P  Pb  Sn  V  Zn  ZP 102b (CSN EN ISO 17294-2; CSN EN 13656; CSN EN 16965)","search_en":"Earths, soils, sludge, sediments, composts, waste, sands Determination of elements by ICP/MS Silver (Ag)  Aluminium (Al)  Arsenic (As)  Barium (Ba)  Beryllium (Be)  Calcium (Ca)  Cadmium (Cd)  Cobalt (Co)  Chromium (Cr)  Copper (Cu)  Iron (Fe)  Potassium (K)  Manganese (Mn)  Magnesium (Mg)  Nickel (Ni)  Phosphorus (P)  Lead (Pb)  Tin (Sn)  Vanadium (V)  Zinc (Zn)  ZP 102b (ČSN EN ISO 17294-2; ČSN EN 13656; ČSN EN 16965)","search_zh":"土、土壤、污泥、沉积物、堆肥、废物、砂 ICP/MS法测定元素 银（Ag）  铝（Al）  砷（As）  钡（Ba）  铍（Be）  钙（Ca）  镉（Cd）  钴（Co）  铬（Cr）  铜（Cu）  铁（Fe）  钾（K）  锰（Mn）  镁（Mg）  镍（Ni）  磷（P）  铅（Pb）  锡（Sn）  钒（V）  锌（Zn）  ZP 102b (ČSN EN ISO 17294-2; ČSN EN 13656; ČSN EN 16965)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":64,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"b002f7665bc853d7ac0a530c","lab_id":"69ad52a4de79e566650fd33a","country":"CZ","accr_number":"1277","accr_body":"ČIA","row_label":"71","test_object":"Sorbenty stałe (emisje, powietrze wewnętrzne i na stanowiskach pracy)","test_object_en":"Solid sorbents (emissions, indoor and workplace air)","test_object_zh":"固体吸附剂（排放、室内和工作场所空气）","test_object_cs":"Pevné sorbenty (emise, vnitřní a pracovní ovzduší)","methodology":"Oznaczanie pierwiastków metodą ICP/MS","methodology_en":"Determination of elements by ICP/MS","methodology_zh":"ICP/MS法测定元素","methodology_cs":"Stanovení prvků metodou ICP/MS","parameters":[{"name":"Arsen (As)","range":""},{"name":"Kadm (Cd)","range":""},{"name":"Kobalt (Co)","range":""},{"name":"Chrom (Cr)","range":""},{"name":"Chrom sześciowartościowy (CrVI)","range":""},{"name":"Miedź (Cu)","range":""},{"name":"Mangan (Mn)","range":""},{"name":"Nikiel (Ni)","range":""},{"name":"Ołów (Pb)","range":""},{"name":"Antymon (Sb)","range":""},{"name":"Cyna (Sn)","range":""},{"name":"Tal (Tl)","range":""},{"name":"Wanad (V)","range":""},{"name":"Cynk (Zn)","range":""},{"name":"Selen (Se)","range":""}],"parameters_en":[{"name":"Arsenic (As)","range":""},{"name":"Cadmium (Cd)","range":""},{"name":"Cobalt (Co)","range":""},{"name":"Chromium (Cr)","range":""},{"name":"Hexavalent chromium (CrVI)","range":""},{"name":"Copper (Cu)","range":""},{"name":"Manganese (Mn)","range":""},{"name":"Nickel (Ni)","range":""},{"name":"Lead (Pb)","range":""},{"name":"Antimony (Sb)","range":""},{"name":"Tin (Sn)","range":""},{"name":"Thallium (Tl)","range":""},{"name":"Vanadium (V)","range":""},{"name":"Zinc (Zn)","range":""},{"name":"Selenium (Se)","range":""}],"parameters_zh":[{"name":"砷（As）","range":""},{"name":"镉（Cd）","range":""},{"name":"钴（Co）","range":""},{"name":"铬（Cr）","range":""},{"name":"六价铬（CrVI）","range":""},{"name":"铜（Cu）","range":""},{"name":"锰（Mn）","range":""},{"name":"镍（Ni）","range":""},{"name":"铅（Pb）","range":""},{"name":"锑（Sb）","range":""},{"name":"锡（Sn）","range":""},{"name":"铊（Tl）","range":""},{"name":"钒（V）","range":""},{"name":"锌（Zn）","range":""},{"name":"硒（Se）","range":""}],"parameters_cs":[{"name":"As","range":""},{"name":"Cd","range":""},{"name":"Co","range":""},{"name":"Cr","range":""},{"name":"CrVI","range":""},{"name":"Cu","range":""},{"name":"Mn","range":""},{"name":"Ni","range":""},{"name":"Pb","range":""},{"name":"Sb","range":""},{"name":"Sn","range":""},{"name":"Tl","range":""},{"name":"V","range":""},{"name":"Zn","range":""},{"name":"Se","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie pierwiastków metodą ICP/MS\nZakres:\nArsen (As)\nKadm (Cd)\nKobalt (Co)\nChrom (Cr)\nChrom sześciowartościowy (CrVI)\nMiedź (Cu)\nMangan (Mn)\nNikiel (Ni)\nOłów (Pb)\nAntymon (Sb)\nCyna (Sn)\nTal (Tl)\nWanad (V)\nCynk (Zn)\nSelen (Se)","reference":"ZP 102c (ČSN EN ISO 17294-2; ČSN EN 14902)","norm_bases":["ZP 102c","ČSN EN ISO 17294-2","ČSN EN 14902"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"noty aplikacyjne Agilent Technologies i Milestone","note_en":"Agilent Technologies and Milestone application notes","note_zh":"Agilent Technologies和Milestone应用说明","note_cs":"aplikační listy Agilent Technologies a Milestone","search_text":"Sorbenty stałe (emisje, powietrze wewnętrzne i na stanowiskach pracy) Oznaczanie pierwiastków metodą ICP/MS Arsen (As)  Kadm (Cd)  Kobalt (Co)  Chrom (Cr)  Chrom sześciowartościowy (CrVI)  Miedź (Cu)  Mangan (Mn)  Nikiel (Ni)  Ołów (Pb)  Antymon (Sb)  Cyna (Sn)  Tal (Tl)  Wanad (V)  Cynk (Zn)  Selen (Se)  Pevné sorbenty (emise, vnitřní a pracovní ovzduší) Stanovení prvků metodou ICP/MS As  Cd  Co  Cr  CrVI  Cu  Mn  Ni  Pb  Sb  Sn  Tl  V  Zn  Se  ZP 102c (ČSN EN ISO 17294-2; ČSN EN 14902) Sorbenty stale (emisje, powietrze wewnetrzne i na stanowiskach pracy) Oznaczanie pierwiastkow metoda ICP/MS Arsen (As)  Kadm (Cd)  Kobalt (Co)  Chrom (Cr)  Chrom szesciowartosciowy (CrVI)  Miedz (Cu)  Mangan (Mn)  Nikiel (Ni)  Olow (Pb)  Antymon (Sb)  Cyna (Sn)  Tal (Tl)  Wanad (V)  Cynk (Zn)  Selen (Se)  Pevne sorbenty (emise, vnitrni a pracovni ovzdusi) Stanoveni prvku metodou ICP/MS As  Cd  Co  Cr  CrVI  Cu  Mn  Ni  Pb  Sb  Sn  Tl  V  Zn  Se  ZP 102c (CSN EN ISO 17294-2; CSN EN 14902)","search_en":"Solid sorbents (emissions, indoor and workplace air) Determination of elements by ICP/MS Arsenic (As)  Cadmium (Cd)  Cobalt (Co)  Chromium (Cr)  Hexavalent chromium (CrVI)  Copper (Cu)  Manganese (Mn)  Nickel (Ni)  Lead (Pb)  Antimony (Sb)  Tin (Sn)  Thallium (Tl)  Vanadium (V)  Zinc (Zn)  Selenium (Se)  ZP 102c (ČSN EN ISO 17294-2; ČSN EN 14902)","search_zh":"固体吸附剂（排放、室内和工作场所空气） ICP/MS法测定元素 砷（As）  镉（Cd）  钴（Co）  铬（Cr）  六价铬（CrVI）  铜（Cu）  锰（Mn）  镍（Ni）  铅（Pb）  锑（Sb）  锡（Sn）  铊（Tl）  钒（V）  锌（Zn）  硒（Se）  ZP 102c (ČSN EN ISO 17294-2; ČSN EN 14902)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":65,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"3537b6cc6826d69d4c413620","lab_id":"69ad52a4de79e566650fd33a","country":"CZ","accr_number":"1277","accr_body":"ČIA","row_label":"73","test_object":"Żywność, suplementy diety","test_object_en":"Food, food supplements","test_object_zh":"食品、膳食补充剂","test_object_cs":"Potraviny, potravinové doplňky","methodology":"Oznaczanie pierwiastków metodą ICP/MS","methodology_en":"Determination of elements by ICP/MS","methodology_zh":"ICP/MS法测定元素","methodology_cs":"Stanovení prvků metodou ICP/MS","parameters":[{"name":"Kadm (Cd)","range":""},{"name":"Miedź (Cu)","range":""},{"name":"Żelazo (Fe)","range":""},{"name":"Ołów (Pb)","range":""},{"name":"Cynk (Zn)","range":""},{"name":"Glin (Al)","range":""},{"name":"Chrom (Cr)","range":""},{"name":"Nikiel (Ni)","range":""},{"name":"Arsen (As)","range":""}],"parameters_en":[{"name":"Cadmium (Cd)","range":""},{"name":"Copper (Cu)","range":""},{"name":"Iron (Fe)","range":""},{"name":"Lead (Pb)","range":""},{"name":"Zinc (Zn)","range":""},{"name":"Aluminium (Al)","range":""},{"name":"Chromium (Cr)","range":""},{"name":"Nickel (Ni)","range":""},{"name":"Arsenic (As)","range":""}],"parameters_zh":[{"name":"镉（Cd）","range":""},{"name":"铜（Cu）","range":""},{"name":"铁（Fe）","range":""},{"name":"铅（Pb）","range":""},{"name":"锌（Zn）","range":""},{"name":"铝（Al）","range":""},{"name":"铬（Cr）","range":""},{"name":"镍（Ni）","range":""},{"name":"砷（As）","range":""}],"parameters_cs":[{"name":"Cd","range":""},{"name":"Cu","range":""},{"name":"Fe","range":""},{"name":"Pb","range":""},{"name":"Zn","range":""},{"name":"Al","range":""},{"name":"Cr","range":""},{"name":"Ni","range":""},{"name":"As","range":""}],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie pierwiastków metodą ICP/MS\nZakres:\nKadm (Cd)\nMiedź (Cu)\nŻelazo (Fe)\nOłów (Pb)\nCynk (Zn)\nGlin (Al)\nChrom (Cr)\nNikiel (Ni)\nArsen (As)","reference":"ZP 102e (ČSN EN ISO 17294-2; ČSN EN 13805)","norm_bases":["ZP 102e","ČSN EN ISO 17294-2","ČSN EN 13805"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"noty aplikacyjne Agilent Technologies i Milestone","note_en":"Agilent Technologies and Milestone application notes","note_zh":"Agilent Technologies和Milestone应用说明","note_cs":"aplikační listy Agilent Technologies a Milestone","search_text":"Żywność, suplementy diety Oznaczanie pierwiastków metodą ICP/MS Kadm (Cd)  Miedź (Cu)  Żelazo (Fe)  Ołów (Pb)  Cynk (Zn)  Glin (Al)  Chrom (Cr)  Nikiel (Ni)  Arsen (As)  Potraviny, potravinové doplňky Stanovení prvků metodou ICP/MS Cd  Cu  Fe  Pb  Zn  Al  Cr  Ni  As  ZP 102e (ČSN EN ISO 17294-2; ČSN EN 13805) Zywnosc, suplementy diety Oznaczanie pierwiastkow metoda ICP/MS Kadm (Cd)  Miedz (Cu)  Zelazo (Fe)  Olow (Pb)  Cynk (Zn)  Glin (Al)  Chrom (Cr)  Nikiel (Ni)  Arsen (As)  Potraviny, potravinove doplnky Stanoveni prvku metodou ICP/MS Cd  Cu  Fe  Pb  Zn  Al  Cr  Ni  As  ZP 102e (CSN EN ISO 17294-2; CSN EN 13805)","search_en":"Food, food supplements Determination of elements by ICP/MS Cadmium (Cd)  Copper (Cu)  Iron (Fe)  Lead (Pb)  Zinc (Zn)  Aluminium (Al)  Chromium (Cr)  Nickel (Ni)  Arsenic (As)  ZP 102e (ČSN EN ISO 17294-2; ČSN EN 13805)","search_zh":"食品、膳食补充剂 ICP/MS法测定元素 镉（Cd）  铜（Cu）  铁（Fe）  铅（Pb）  锌（Zn）  铝（Al）  铬（Cr）  镍（Ni）  砷（As）  ZP 102e (ČSN EN ISO 17294-2; ČSN EN 13805)","categories":["food"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":66,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"fd7c894e5ca0c398afdf8470","lab_id":"69ad52a4de79e566650fd33a","country":"CZ","accr_number":"1277","accr_body":"ČIA","row_label":"74","test_object":"Grunty, gleby, osady, osady denne, komposty, odpady","test_object_en":"Earths, soils, sludge, sediments, composts, waste","test_object_zh":"土、土壤、污泥、沉积物、堆肥、废物","test_object_cs":"Zeminy, půdy, kaly, sedimenty, komposty, odpady","methodology":"Oznaczanie ekstrahowalnych halogenów organicznie związanych (EOX) metodą kulometryczną","methodology_en":"Determination of extractable organically bound halogens (EOX) by coulometry","methodology_zh":"可萃取有机卤素（EOX）测定（库仑法）","methodology_cs":"Stanovení extrahovatelných organicky vázaných halogenů (EOX) coulometricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie ekstrahowalnych halogenów organicznie związanych (EOX) metodą kulometryczną","reference":"ZP 077 (DIN 38414-17; návod firmy Labtech)","norm_bases":["ZP 077","DIN 38414-17","návod firmy Labtech"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Grunty, gleby, osady, osady denne, komposty, odpady Oznaczanie ekstrahowalnych halogenów organicznie związanych (EOX) metodą kulometryczną Zeminy, půdy, kaly, sedimenty, komposty, odpady Stanovení extrahovatelných organicky vázaných halogenů (EOX) coulometricky ZP 077 (DIN 38414-17; návod firmy Labtech) Grunty, gleby, osady, osady denne, komposty, odpady Oznaczanie ekstrahowalnych halogenow organicznie zwiazanych (EOX) metoda kulometryczna Zeminy, pudy, kaly, sedimenty, komposty, odpady Stanoveni extrahovatelnych organicky vazanych halogenu (EOX) coulometricky ZP 077 (DIN 38414-17; navod firmy Labtech)","search_en":"Earths, soils, sludge, sediments, composts, waste Determination of extractable organically bound halogens (EOX) by coulometry ZP 077 (DIN 38414-17; návod firmy Labtech)","search_zh":"土、土壤、污泥、沉积物、堆肥、废物 可萃取有机卤素（EOX）测定（库仑法） ZP 077 (DIN 38414-17; návod firmy Labtech)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":67,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"64b78d9b77271f6ceab96416","lab_id":"69ad52a4de79e566650fd33a","country":"CZ","accr_number":"1277","accr_body":"ČIA","row_label":"75","test_object":"Grunty, gleby, osady, osady denne, komposty, odpady","test_object_en":"Earths, soils, sludge, sediments, composts, waste","test_object_zh":"土、土壤、污泥、沉积物、堆肥、废物","test_object_cs":"Zeminy, půdy, kaly, sedimenty, komposty, odpady","methodology":"Oznaczanie aktywności oddechowej (AT4) przez pomiar zużycia tlenu po 4 dniach metodą kulometryczną","methodology_en":"Determination of respiration activity (AT4) by measuring oxygen consumption after 4 days by coulometry","methodology_zh":"库仑法测定4日耗氧量以确定呼吸活性（AT4）","methodology_cs":"Stanovení respirační aktivity (AT4) měřením spotřeby kyslíku po 4 dnech coulometricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie aktywności oddechowej (AT4) przez pomiar zużycia tlenu po 4 dniach metodą kulometryczną","reference":"ZP 078 (ONORM S 2027-4; Návod firmy DIRAM)","norm_bases":["ZP 078","ONORM S 2027-4","Návod firmy DIRAM"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Grunty, gleby, osady, osady denne, komposty, odpady Oznaczanie aktywności oddechowej (AT4) przez pomiar zużycia tlenu po 4 dniach metodą kulometryczną Zeminy, půdy, kaly, sedimenty, komposty, odpady Stanovení respirační aktivity (AT4) měřením spotřeby kyslíku po 4 dnech coulometricky ZP 078 (ONORM S 2027-4; Návod firmy DIRAM) Grunty, gleby, osady, osady denne, komposty, odpady Oznaczanie aktywnosci oddechowej (AT4) przez pomiar zuzycia tlenu po 4 dniach metoda kulometryczna Zeminy, pudy, kaly, sedimenty, komposty, odpady Stanoveni respiracni aktivity (AT4) merenim spotreby kysliku po 4 dnech coulometricky ZP 078 (ONORM S 2027-4; Navod firmy DIRAM)","search_en":"Earths, soils, sludge, sediments, composts, waste Determination of respiration activity (AT4) by measuring oxygen consumption after 4 days by coulometry ZP 078 (ONORM S 2027-4; Návod firmy DIRAM)","search_zh":"土、土壤、污泥、沉积物、堆肥、废物 库仑法测定4日耗氧量以确定呼吸活性（AT4） ZP 078 (ONORM S 2027-4; Návod firmy DIRAM)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":68,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"4349d9dcaa140362094f5989","lab_id":"69ad52a4de79e566650fd33a","country":"CZ","accr_number":"1277","accr_body":"ČIA","row_label":"1","test_object":"Wody: przeznaczone do spożycia, butelkowane, surowe, uzdatnione, ciepłe","test_object_en":"Drinking, bottled, raw, treated, hot water","test_object_zh":"饮用水、瓶装水、原水、成品水、热水","test_object_cs":"Vody pitné, balené, surové, vyrobené, teplé","methodology":"Pobieranie próbek wody przeznaczonej do spożycia","methodology_en":"Sampling of drinking water","methodology_zh":"饮用水采样","methodology_cs":"Odběry vzorků pitných vod","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pobieranie próbek wody przeznaczonej do spożycia","reference":"VZ 01 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-5; ČSN EN ISO 5667-14; ČSN EN ISO 19458)","norm_bases":["VZ 01","ČSN EN ISO 5667-1","ČSN EN ISO 5667-3","ČSN ISO 5667-5","ČSN EN ISO 5667-14","ČSN EN ISO 19458"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody: przeznaczone do spożycia, butelkowane, surowe, uzdatnione, ciepłe Pobieranie próbek wody przeznaczonej do spożycia Vody pitné, balené, surové, vyrobené, teplé Odběry vzorků pitných vod VZ 01 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-5; ČSN EN ISO 5667-14; ČSN EN ISO 19458) Wody: przeznaczone do spozycia, butelkowane, surowe, uzdatnione, cieple Pobieranie probek wody przeznaczonej do spozycia Vody pitne, balene, surove, vyrobene, teple Odbery vzorku pitnych vod VZ 01 (CSN EN ISO 5667-1; CSN EN ISO 5667-3; CSN ISO 5667-5; CSN EN ISO 5667-14; CSN EN ISO 19458)","search_en":"Drinking, bottled, raw, treated, hot water Sampling of drinking water VZ 01 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-5; ČSN EN ISO 5667-14; ČSN EN ISO 19458)","search_zh":"饮用水、瓶装水、原水、成品水、热水 饮用水采样 VZ 01 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-5; ČSN EN ISO 5667-14; ČSN EN ISO 19458)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":69,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"df4b3248d48eecd0a7920402","lab_id":"69ad52a4de79e566650fd33a","country":"CZ","accr_number":"1277","accr_body":"ČIA","row_label":"2","test_object":"Ścieki","test_object_en":"Waste water","test_object_zh":"废水","test_object_cs":"Vody odpadní","methodology":"Pobieranie próbek ścieków (ręczne, automatycznym próbnikiem)","methodology_en":"Sampling of waste water (manual sampling, automatic sampler)","methodology_zh":"废水采样（手动、自动采样器）","methodology_cs":"Odběry vzorků odpadních vod (manuální odběr, odběr automatickým vzorkovačem)","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pobieranie próbek ścieków (ręczne, automatycznym próbnikiem)","reference":"VZ 02 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-10; ČSN EN ISO 5667-14; ČSN 75 7315)","norm_bases":["VZ 02","ČSN EN ISO 5667-1","ČSN EN ISO 5667-3","ČSN ISO 5667-10","ČSN EN ISO 5667-14","ČSN 75 7315"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Ścieki Pobieranie próbek ścieków (ręczne, automatycznym próbnikiem) Vody odpadní Odběry vzorků odpadních vod (manuální odběr, odběr automatickým vzorkovačem) VZ 02 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-10; ČSN EN ISO 5667-14; ČSN 75 7315) Scieki Pobieranie probek sciekow (reczne, automatycznym probnikiem) Vody odpadni Odbery vzorku odpadnich vod (manualni odber, odber automatickym vzorkovacem) VZ 02 (CSN EN ISO 5667-1; CSN EN ISO 5667-3; CSN ISO 5667-10; CSN EN ISO 5667-14; CSN 75 7315)","search_en":"Waste water Sampling of waste water (manual sampling, automatic sampler) VZ 02 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-10; ČSN EN ISO 5667-14; ČSN 75 7315)","search_zh":"废水 废水采样（手动、自动采样器） VZ 02 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-10; ČSN EN ISO 5667-14; ČSN 75 7315)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":70,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"bbdae5f96761b5e51ee4efe5","lab_id":"69ad52a4de79e566650fd33a","country":"CZ","accr_number":"1277","accr_body":"ČIA","row_label":"3","test_object":"Wody powierzchniowe","test_object_en":"Surface water","test_object_zh":"地表水","test_object_cs":"Vody povrchové","methodology":"Pobieranie próbek wód powierzchniowych","methodology_en":"Sampling of surface water","methodology_zh":"地表水采样","methodology_cs":"Odběry vzorků povrchových vod","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pobieranie próbek wód powierzchniowych","reference":"VZ 03 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-4; ČSN EN ISO 5667-6; ČSN EN ISO 5667-14)","norm_bases":["VZ 03","ČSN EN ISO 5667-1","ČSN EN ISO 5667-3","ČSN ISO 5667-4","ČSN EN ISO 5667-6","ČSN EN ISO 5667-14"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody powierzchniowe Pobieranie próbek wód powierzchniowych Vody povrchové Odběry vzorků povrchových vod VZ 03 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-4; ČSN EN ISO 5667-6; ČSN EN ISO 5667-14) Wody powierzchniowe Pobieranie probek wod powierzchniowych Vody povrchove Odbery vzorku povrchovych vod VZ 03 (CSN EN ISO 5667-1; CSN EN ISO 5667-3; CSN ISO 5667-4; CSN EN ISO 5667-6; CSN EN ISO 5667-14)","search_en":"Surface water Sampling of surface water VZ 03 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-4; ČSN EN ISO 5667-6; ČSN EN ISO 5667-14)","search_zh":"地表水 地表水采样 VZ 03 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-4; ČSN EN ISO 5667-6; ČSN EN ISO 5667-14)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":71,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"b7113da310ee67d60e98e6e6","lab_id":"69ad52a4de79e566650fd33a","country":"CZ","accr_number":"1277","accr_body":"ČIA","row_label":"4","test_object":"Woda w kąpieliskach i do celów leczniczych","test_object_en":"Bathing and therapeutic water","test_object_zh":"游泳/浴用和医疗用水","test_object_cs":"Vody ke koupání a léčebným účelům","methodology":"Pobieranie próbek wody w kąpieliskach","methodology_en":"Sampling of bathing water","methodology_zh":"游泳/浴用水采样","methodology_cs":"Odběry vzorků vod ke koupání","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pobieranie próbek wody w kąpieliskach","reference":"VZ 04 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN EN ISO 5667-14; ČSN EN ISO 19458)","norm_bases":["VZ 04","ČSN EN ISO 5667-1","ČSN EN ISO 5667-3","ČSN EN ISO 5667-14","ČSN EN ISO 19458"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Woda w kąpieliskach i do celów leczniczych Pobieranie próbek wody w kąpieliskach Vody ke koupání a léčebným účelům Odběry vzorků vod ke koupání VZ 04 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN EN ISO 5667-14; ČSN EN ISO 19458) Woda w kapieliskach i do celow leczniczych Pobieranie probek wody w kapieliskach Vody ke koupani a lecebnym ucelum Odbery vzorku vod ke koupani VZ 04 (CSN EN ISO 5667-1; CSN EN ISO 5667-3; CSN EN ISO 5667-14; CSN EN ISO 19458)","search_en":"Bathing and therapeutic water Sampling of bathing water VZ 04 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN EN ISO 5667-14; ČSN EN ISO 19458)","search_zh":"游泳/浴用和医疗用水 游泳/浴用水采样 VZ 04 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN EN ISO 5667-14; ČSN EN ISO 19458)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":72,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"90385d30d3cc6e642c1c46c0","lab_id":"69ad52a4de79e566650fd33a","country":"CZ","accr_number":"1277","accr_body":"ČIA","row_label":"5","test_object":"Wody podziemne","test_object_en":"Ground water","test_object_zh":"地下水","test_object_cs":"Vody podzemní","methodology":"Pobieranie próbek wód podziemnych (ręczne, pompowaniem)","methodology_en":"Sampling of ground water (manual sampling, pumping)","methodology_zh":"地下水采样（手动、泵抽）","methodology_cs":"Odběry vzorků podzemních vod (manuální odběr, odběr čerpáním)","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pobieranie próbek wód podziemnych (ręczne, pompowaniem)","reference":"VZ 05 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-11; ČSN EN ISO 5667-14)","norm_bases":["VZ 05","ČSN EN ISO 5667-1","ČSN EN ISO 5667-3","ČSN ISO 5667-11","ČSN EN ISO 5667-14"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Wody podziemne Pobieranie próbek wód podziemnych (ręczne, pompowaniem) Vody podzemní Odběry vzorků podzemních vod (manuální odběr, odběr čerpáním) VZ 05 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-11; ČSN EN ISO 5667-14) Wody podziemne Pobieranie probek wod podziemnych (reczne, pompowaniem) Vody podzemni Odbery vzorku podzemnich vod (manualni odber, odber cerpanim) VZ 05 (CSN EN ISO 5667-1; CSN EN ISO 5667-3; CSN ISO 5667-11; CSN EN ISO 5667-14)","search_en":"Ground water Sampling of ground water (manual sampling, pumping) VZ 05 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-11; ČSN EN ISO 5667-14)","search_zh":"地下水 地下水采样（手动、泵抽） VZ 05 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-11; ČSN EN ISO 5667-14)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":73,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"6b01f98d0debdcb5bca55a98","lab_id":"69ad52a4de79e566650fd33a","country":"CZ","accr_number":"1277","accr_body":"ČIA","row_label":"6","test_object":"Grunty, gleby, osady, osady denne, komposty, odpady, piaski","test_object_en":"Earths, soils, sludge, sediments, composts, waste, sands","test_object_zh":"土、土壤、污泥、沉积物、堆肥、废物、砂","test_object_cs":"Zeminy, půdy, kaly, sedimenty, komposty, odpady, písky","methodology":"Pobieranie próbek odpadów i substancji stałych","methodology_en":"Sampling of waste and solids","methodology_zh":"废物和固体采样","methodology_cs":"Odběry vzorků odpadů a pevných látek","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pobieranie próbek odpadów i substancji stałych","reference":"VZ 07 (Metodický pokyn MŽP ke vzorkování odpadů – duben 2008; ČSN EN 14899)","norm_bases":["VZ 07","Metodický pokyn MŽP ke vzorkování odpadů – duben 2008","ČSN EN 14899"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Grunty, gleby, osady, osady denne, komposty, odpady, piaski Pobieranie próbek odpadów i substancji stałych Zeminy, půdy, kaly, sedimenty, komposty, odpady, písky Odběry vzorků odpadů a pevných látek VZ 07 (Metodický pokyn MŽP ke vzorkování odpadů – duben 2008; ČSN EN 14899) Grunty, gleby, osady, osady denne, komposty, odpady, piaski Pobieranie probek odpadow i substancji stalych Zeminy, pudy, kaly, sedimenty, komposty, odpady, pisky Odbery vzorku odpadu a pevnych latek VZ 07 (Metodicky pokyn MZP ke vzorkovani odpadu – duben 2008; CSN EN 14899)","search_en":"Earths, soils, sludge, sediments, composts, waste, sands Sampling of waste and solids VZ 07 (Metodický pokyn MŽP ke vzorkování odpadů – duben 2008; ČSN EN 14899)","search_zh":"土、土壤、污泥、沉积物、堆肥、废物、砂 废物和固体采样 VZ 07 (Metodický pokyn MŽP ke vzorkování odpadů – duben 2008; ČSN EN 14899)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":74,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"4532f2de3a24d28123868e70","lab_id":"69ad52a4de79e566650fd33a","country":"CZ","accr_number":"1277","accr_body":"ČIA","row_label":"8","test_object":"Osady, osady denne","test_object_en":"Sludge, sediments","test_object_zh":"污泥、沉积物","test_object_cs":"Kaly, sedimenty","methodology":"Pobieranie próbek osadów i osadów dennych","methodology_en":"Sampling of sludge and sediments","methodology_zh":"污泥和沉积物采样","methodology_cs":"Odběry vzorků kalů a sedimetů","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pobieranie próbek osadów i osadów dennych","reference":"VZ 10 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN EN ISO 5667-13; ČSN ISO 5667-12; ČSN EN ISO 5667-14; ČSN EN ISO 5667-15)","norm_bases":["VZ 10","ČSN EN ISO 5667-1","ČSN EN ISO 5667-3","ČSN EN ISO 5667-13","ČSN ISO 5667-12","ČSN EN ISO 5667-14","ČSN EN ISO 5667-15"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Osady, osady denne Pobieranie próbek osadów i osadów dennych Kaly, sedimenty Odběry vzorků kalů a sedimetů VZ 10 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN EN ISO 5667-13; ČSN ISO 5667-12; ČSN EN ISO 5667-14; ČSN EN ISO 5667-15) Osady, osady denne Pobieranie probek osadow i osadow dennych Kaly, sedimenty Odbery vzorku kalu a sedimetu VZ 10 (CSN EN ISO 5667-1; CSN EN ISO 5667-3; CSN EN ISO 5667-13; CSN ISO 5667-12; CSN EN ISO 5667-14; CSN EN ISO 5667-15)","search_en":"Sludge, sediments Sampling of sludge and sediments VZ 10 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN EN ISO 5667-13; ČSN ISO 5667-12; ČSN EN ISO 5667-14; ČSN EN ISO 5667-15)","search_zh":"污泥、沉积物 污泥和沉积物采样 VZ 10 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN EN ISO 5667-13; ČSN ISO 5667-12; ČSN EN ISO 5667-14; ČSN EN ISO 5667-15)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":75,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"}],"has_pdf":true}