🇨🇿 VODÁRENSKÁ AKCIOVÁ SPOLEČNOST, a.s. PL
Water & wastewaterMicrobiologyEnvironment
VODÁRENSKÁ AKCIOVÁ SPOLEČNOST, a.s. is a laboratory accredited by ČIA under number 1249 (Brno, Czech Republic). Its accreditation scope covers 344 test methods in the following areas: Water & wastewater, Microbiology, Environment. Test objects include: Drinking, ground and surface water, Drinking, ground, surface and waste water, Drinking, ground and surface water, bathing water, Surface and waste water.
At a glance
- Accreditation number: ČIA 1249
- Methods in scope: 344
- Types of test objects: 22
- City: Brno, Czech Republic
- Valid until: 26-03-2031
- Accreditation number
- 1249
- Accreditation body
- ČIA
- Address
- Soběšická 151, Lesná, 638 00 Brno
- City
- Brno, Czech Republic
- Division
- Laboratoria Gospodarki Wodnej
- Valid until
- 26-03-2031
What this laboratory tests (22)
- Drinking, ground and surface water — 144 methods
- Drinking, ground, surface and waste water — 45 methods
- Drinking, ground and surface water, bathing water — 29 methods
- Surface and waste water — 22 methods
- Solid matrices — 19 methods
- Drinking, ground, surface and waste water, leachates of solid materials and waste — 17 methods
- Waste water — 8 methods
- Drinking water, bathing water — 7 methods
- Drinking, ground, surface and waste water, bathing water — 7 methods
- Ground, surface and waste water — 7 methods
- Surface water — 7 methods
- Drinking, hot and bottled water — 6 methods
- Ground water — 6 methods
- Sewage and waterworks sludges, sands, screenings, suspended sediments, river sediments — 6 methods
- Bathing water — 3 methods
- and 7 more
Laboratory sections (8)
- Workplace Brno — 100 methods
- Workplace Žďár nad Sázavou — 49 methods
- Workplace Boskovice — 47 methods
- Workplace Jihlava — 44 methods
- Workplace Třebíč – drinking water laboratory — 38 methods
- Workplace Znojmo – drinking water laboratory — 36 methods
- Workplace Třebíč – waste water laboratory — 15 methods
- Workplace Znojmo – waste water laboratory — 15 methods
Laboratory locations
- Pracownia Brno — Soběšická 821/151, Lesná
- Pracownia Boskovice — ÚV, Újezd u Boskovic 193
- Pracownia Igława — Žižkova 1867/93
- Pracownia Třebíč – laboratorium wód pitnych — Kubišova 1172/11
- Pracownia Třebíč – laboratorium ścieków — Brněnská, ČOV
- Pracownia Znojmo – laboratorium wód pitnych — Pražská 2801/119
- Pracownia Znojmo – laboratorium ścieków — Dyjská 241
- Pracownia Żdziar nad Sazawą — Studentská 1133/3
Certificate information
- Certificate date
- 03.09.2026
Accreditation scope — test methods (344)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Workplace Brno | |||||
| 1 | Drinking, ground, surface and waste water, bathing water, leachates of solid materials and waste | Determination of pH by potentiometry Regulated area: Tests |
SOP č.1 (ČSN ISO 10523) | ||
| 2 | Solid matrices | Determination of pH by potentiometry Regulated area: Tests |
SOP č.2-1 (ČSN EN ISO 10390) | ||
| 3 | Drinking, ground, surface and waste water, leachates of solid materials and waste | Determination of electrical conductivity Regulated area: Tests |
SOP č.3 (ČSN EN 27888) | ||
| 4 | Drinking, ground, surface and waste water, leachates of solid materials and waste | Determination of fluoride with an ion-selective electrode Regulated area: Tests |
SOP č.4-1 (ČSN ISO 10359-1) | ||
| 5 | Drinking, ground and surface water | Spectrophotometric determination of absorbance at 254 nm Regulated area: Tests |
SOP č.5 (ČSN 75 7360) | ||
| 6 | Drinking, ground, surface and waste water, leachates of solid materials and waste | Gravimetric determination of dissolved and total solids, loss on ignition and dissolved inorganic salts (RAS) Regulated area: Tests |
SOP č.6 (ČSN 75 7346; ČSN 75 7347) | ||
| 7 | Drinking, ground, surface and waste water, leachates of solid materials and waste | Gravimetric determination of suspended solids and loss on ignition Regulated area: Tests |
SOP č.7 (ČSN EN 872; ČSN 75 7350) | ||
| 8 | Solid matrices | Gravimetric determination of total solids (dry matter) and water content Regulated area: Tests |
SOP č.8 (ČSN EN 15934) | ||
| 9 | Solid matrices | Gravimetric determination of loss on ignition Regulated area: Tests |
SOP č.9 (ČSN EN 15935) | ||
| 10 | Drinking, ground and surface water, bathing water | Titrimetric determination of chemical oxygen demand with permanganate (CODMn) Regulated area: Tests |
SOP č.10 (ČSN EN ISO 8467) | ||
| 11 | Drinking, ground, surface and waste water, leachates of solid materials and waste | Spectrophotometric determination of chemical oxygen demand with dichromate (CODCr) using HACH test kit Regulated area: Tests |
SOP č.11 (ČSN ISO 15705; návod firmy HACH) | ||
| 12 | Drinking, ground, surface and waste water | Determination of biochemical oxygen demand after 5 days (BOD5) with LDO probe Regulated area: Tests |
SOP č.12 (ČSN EN ISO 5815-1; ČSN EN 1899-2) | ||
| 13 | Drinking, ground, surface and waste water, bathing water | Spectrophotometric determination of ammonium ions and ammonia nitrogen Regulated area: Tests |
SOP č.13 (ČSN ISO 7150-1) | ||
| 14 | Drinking, ground, surface and waste water, leachates of solid materials and waste | Spectrophotometric determination of nitrite and nitrite nitrogen Regulated area: Tests |
SOP č.14 (ČSN EN 26777) | ||
| 15 | Drinking, ground, surface and waste water, bathing water | Spectrophotometric determination of nitrate and nitrate nitrogen and calculation of inorganic nitrogen from measured values Regulated area: Tests |
SOP č.15 (ČSN ISO 7890-3) | ||
| 16 | Solid matrices | Spectrophotometric determination of organic nitrogen by Kjeldahl Regulated area: Tests |
SOP č.16-1 (ČSN EN 13342) | ||
| 17 | Drinking, ground, surface and waste water, leachates of solid materials and waste | Titrimetric determination of chloride Regulated area: Tests |
SOP č.17 (ČSN ISO 9297) | ||
| 18 | Waste water, leachates of solid materials and waste | Spectrophotometric determination of sulphate using HACH test kit Regulated area: Tests |
SOP č.18-1 (návod firmy HACH) | ||
| 19 | Surface and waste water | Spectrophotometric determination of nitrate nitrogen using HACH test kit and calculation of nitrate from measured values Regulated area: Tests |
SOP č.19 (návod firmy HACH) | ||
| 20 | Surface and waste water | Spectrophotometric determination of nitrite nitrogen using HACH test kit and calculation of nitrite from measured values Regulated area: Tests |
SOP č.20 (návod firmy HACH) | ||
| 21 | Drinking, ground, surface and waste water | Spectrophotometric determination of dissolved sulphides using HACH test kit Regulated area: Tests |
SOP č.21-1 (ČSN ISO 10530; návod firmy HACH) | ||
| 22 | Drinking, ground and surface water | Titrimetric determination of acid neutralising capacity (ANC) Regulated area: Tests |
SOP č.22 (ČSN EN ISO 9963-1) | ||
| 23 | Drinking, ground and surface water | Titrimetric determination of base neutralising capacity (BNC) Regulated area: Tests |
SOP č.23 (ČSN 75 7372) | ||
| 24 | Drinking, ground and surface water, bathing water | Determination of turbidity by nephelometry Regulated area: Tests |
SOP č.24 (ČSN EN ISO 7027-1) | ||
| 25 | Drinking, ground and surface water | Spectrophotometric determination of colour by measuring absorbance at 410 nm Regulated area: Tests |
SOP č.25 (ČSN EN ISO 7887; Metoda C) | ||
| 26 | Drinking water, bathing water | Spectrophotometric determination of free and total chlorine using HACH test kit and calculation of bound chlorine from measured values Regulated area: Tests |
SOP č.26 (ČSN EN ISO 7393-2; návod firmy HACH) | ||
| 27 | Drinking, ground, surface and waste water, bathing water | Measurement of water temperature Regulated area: Tests |
SOP č.27 (ČSN 75 7342) | ||
| 28 | Drinking, ground and surface water | Preliminary sensory determination of odour and taste Regulated area: Tests |
SOP č.28 (ČSN EN 1622; ČSN 75 7340) | ||
| 29 | Drinking, ground, surface and waste water, bathing water | Determination of dissolved oxygen by luminescence method with LDO probe Regulated area: Tests |
SOP č.29 (ČSN ISO 17289; návod firmy HACH) | ||
| 30 | Drinking, ground, surface and waste water, leachates of solid materials and waste | Determination of total nitrogen after oxidation to nitrogen oxides with TOC/TN analyser Regulated area: Tests |
SOP č.30-1 (ČSN EN ISO 20236) | ||
| 31 | Drinking, ground, surface and waste water, leachates of solid materials and waste | Spectrophotometric determination of phenols after distillation Regulated area: Tests |
SOP č.31-1 (ČSN ISO 6439) | ||
| 32 | Drinking, ground, surface and waste water, leachates of solid materials and waste | Spectrophotometric determination of cyanides after distillation Regulated area: Tests |
SOP č.32-1 (ČSN 75 7415) | ||
| 33 | Drinking, ground and surface water | Spectrophotometric determination of humic substances Regulated area: Tests |
SOP č.33 (ČSN 75 7536) | ||
| 34 | Drinking, ground, surface and waste water, leachates of solid materials and waste | Spectrophotometric determination of anionic surfactants Regulated area: Tests |
SOP č.34-1 (ČSN EN 903) | ||
| 35 | Ground, surface and waste water | Gravimetric determination of extractable substances (EL) Regulated area: Tests |
SOP č.35 (ČSN 75 7508) | ||
| 36 | Drinking, ground and surface water, bathing water | Determination of dissolved anions by ion chromatography with conductivity detection fluorides chlorides nitrites nitrates sulphates phosphates chlorites chlorates bromates sum of chlorites and chlorates by calculation (calculated) Regulated area: Tests |
SOP č.36-1 (ČSN EN ISO 10304-1; ČSN EN ISO 10304-4; ČSN EN ISO 15061) | ||
| 37 | Drinking, ground and surface water | Determination of pH by potentiometry with Gallery automatic analyser Regulated area: Tests |
SOP č.37 (návod firmy Thermo Scientific) | ||
| 38 | Drinking, ground and surface water | Determination of electrical conductivity with Gallery automatic analyser Regulated area: Tests |
SOP č.38 (návod firmy Thermo Scientific) | ||
| 39 | Drinking, ground and surface water | Spectrophotometric determination of ammonium ions with Gallery automatic analyser Regulated area: Tests |
SOP č.39 (návod firmy Thermo Scientific) | ||
| 40 | Drinking, ground and surface water | Spectrophotometric determination of nitrate with Gallery automatic analyser Regulated area: Tests |
SOP č.40 (návod firmy Thermo Scientific) | ||
| 41 | Drinking, ground and surface water | Spectrophotometric determination of nitrite with Gallery automatic analyser Regulated area: Tests |
SOP č.41 (návod firmy Thermo Scientific) | ||
| 42 | Drinking, ground and surface water | Spectrophotometric determination of phosphate with Gallery automatic analyser Regulated area: Tests |
SOP č.42 (návod firmy Thermo Scientific) | ||
| 43 | Drinking, ground and surface water | Spectrophotometric determination of chloride with Gallery automatic analyser Regulated area: Tests |
SOP č.43 (návod firmy Thermo Scientific) | ||
| 44 | Drinking, ground and surface water | Spectrophotometric determination of sulphate with Gallery automatic analyser Regulated area: Tests |
SOP č.44 (návod firmy Thermo Scientific) | ||
| 45 | Drinking, ground and surface water | Spectrophotometric determination of acid neutralising capacity (ANC) with Gallery automatic analyser Regulated area: Tests |
SOP č.45 (návod firmy Thermo Scientific) | ||
| 46 | Drinking, ground and surface water | Spectrophotometric determination of colour with Gallery automatic analyser Regulated area: Tests |
SOP č.46 (návod firmy Thermo Scientific) | ||
| 47 | Drinking, ground and surface water | Spectrophotometric determination of calcium with Gallery automatic analyser and calculation of the sum of calcium and magnesium Regulated area: Tests |
SOP č.47 (návod firmy Thermo Scientific) | ||
| 48 | Drinking, ground and surface water | Spectrophotometric determination of magnesium with Gallery automatic analyser and calculation of the sum of calcium and magnesium Regulated area: Tests |
SOP č.48 (návod firmy Thermo Scientific) | ||
| 49 | Drinking, ground and surface water | Spectrophotometric determination of iron with Gallery automatic analyser Regulated area: Tests |
SOP č.49 (návod firmy Thermo Scientific) | ||
| 50 | Drinking, ground and surface water | Spectrophotometric determination of manganese with Gallery automatic analyser Regulated area: Tests |
SOP č.50 (návod firmy Thermo Scientific) | ||
| 51 | Drinking, ground and surface water | Spectrophotometric determination of aluminium with Gallery automatic analyser Regulated area: Tests |
SOP č.51 (návod firmy Thermo Scientific) | ||
| 52 | Aqueous leachates of solid materials and waste | Spectrophotometric determination of nitrate and nitrate nitrogen Regulated area: Tests |
SOP č.52-1 (ČSN EN 12457-4; ČSN ISO 7890-3) | ||
| 53 | Aqueous leachates of solid materials and waste | Spectrophotometric determination of ammonium ions and ammonia nitrogen Regulated area: Tests |
SOP č.53-1 (ČSN EN 12457-4; ČSN ISO 7150-1) | ||
| 54 | Drinking, ground, surface and waste water | Spectrophotometric determination of anionic surfactants using a test kit Regulated area: Tests |
SOP č.54 (návod firmy HACH, MERCK) | ||
| 55 | Drinking, ground and surface water | Microscopic determination of abioseston Regulated area: Tests |
SOP č.55 (ČSN 75 7713) | ||
| 56 | Drinking, ground and surface water | Microscopic determination of bioseston Regulated area: Tests |
SOP č.56 (ČSN 75 7712) | ||
| 57 | Drinking, ground and surface water, bathing water | Enumeration of Escherichia coli and coliform bacteria by membrane filtration Regulated area: Tests |
SOP č.57 (ČSN EN ISO 9308-1) | ||
| 58 | Drinking, ground and surface water | Enumeration of thermotolerant coliform bacteria and Escherichia coli by membrane filtration Regulated area: Tests |
SOP č.58 (ČSN 75 7835) | ||
| 59 | Drinking, ground and surface water, bathing water | Enumeration of intestinal enterococci by membrane filtration Regulated area: Tests |
SOP č.59 (ČSN EN ISO 7899-2) | ||
| 60 | Drinking, ground and surface water, bathing water | Enumeration of culturable microorganisms by inoculation in a nutrient agar culture medium at 36 °C and 22 °C Regulated area: Tests |
SOP č.60 (ČSN EN ISO 6222) | ||
| 61 | Drinking, ground and surface water, bathing water | Enumeration of Escherichia coli and coliform bacteria by most probable number method with a commercial kit Regulated area: Tests |
SOP č.62 (ČSN EN ISO 9308-2; návod výrobce IDEXX, Xebios) | ||
| 62 | Drinking, ground, surface and waste water | Detection of Salmonella by culture Regulated area: Tests |
SOP č.63-1 (ČSN ISO 19250) | ||
| 63 | Solid matrices | Enumeration of thermotolerant coliform bacteria by culture Regulated area: Tests |
SOP č.64 (ČSN 75 7835; AHEM č. 7/2001; AHEM č. 1/2008) | ||
| 64 | Solid matrices | Enumeration of intestinal enterococci by culture Regulated area: Tests |
SOP č.65 (ČSN EN ISO 7899-2; AHEM č. 7/2001; AHEM č. 1/2008) | ||
| 65 | Solid matrices | Detection of Salmonella by culture Regulated area: Tests |
SOP č.66-1 (ČSN EN ISO 6579-1; AHEM č. 7/2001; AHEM č. 1/2008) | ||
| 66 | Drinking water, bathing water | Enumeration of Legionella by membrane filtration Regulated area: Tests |
SOP č.67 (ČSN EN ISO 11731) | ||
| 67 | Drinking, ground and surface water, bathing water | Enumeration of Staphylococcus aureus by membrane filtration Regulated area: Tests |
SOP č.68 (ČSN EN ISO 6888-1) | ||
| 68 | Drinking, ground and surface water, bathing water | Enumeration of Pseudomonas aeruginosa by membrane filtration Regulated area: Tests |
SOP č.69 (ČSN EN ISO 16266) | ||
| 69 | Drinking, ground and surface water | Enumeration of Clostridium perfringens by membrane filtration Regulated area: Tests |
SOP č.70 (ČSN EN ISO 14189) | ||
| 70 | Drinking, ground, surface and waste water, leachates of solid materials and waste | Determination of the inhibitory effect on the light emission of luminescent bacteria Aliivibrio fischeri Regulated area: Tests |
SOP č.71-1 (ČSN EN ISO 11348-2; ČSN EN ISO 11348-3) | ||
| 71 | Drinking, ground, surface and waste water, leachates of solid materials and waste | Determination of polychlorinated biphenyls (PCB) by gas chromatography (GC/ECD) and calculation of the sum of PCB PCB congeners 28, 52, 101, 118, 138, 153, 180 sum of PCB by calculation (calculated) Regulated area: Tests |
SOP č.72-1 (ČSN EN ISO 6468) | ||
| 72 | Solid matrices | Determination of polychlorinated biphenyls (PCB) by gas chromatography (GC/ECD) and calculation of the sum of PCB PCB congeners 28, 52, 101, 118, 138, 153, 180 sum of PCB by calculation (calculated) Regulated area: Tests |
SOP č.73-1 (DIN 38414-20; ČSN EN 17322) | ||
| 73 | Drinking, ground, surface and waste water, leachates of solid materials and waste | Determination of volatile organic compounds (VOC) by purge and trap and gas chromatography (GC/FID+ECD) and calculation of the sum of trihalomethanes (THM) 1,1-dichloroethene o,m,p-dichlorobenzenes 1,2-dichloroethane cis-1,2-dichloroethene trans-1,2-dichloroethene benzene toluene o,m,p-xylenes styrene ethylbenzene chlorobenzene bromodichloromethane dibromochloromethane chloroform bromoform dichloromethane trichloroethene tetrachloroethene tetrachloromethane 1,1-dichloroethane 1,1,1-trichloroethane 1,2-dichloropropane 1,1,2-trichloroethane 1,1,2,2-tetrachloroethane sum of trihalomethanes by calculation (calculated) Regulated area: Tests |
SOP č.75-1 (ČSN EN ISO 10301; ČSN EN ISO 15680) | ||
| 74 | Solid matrices | Determination of volatile organic compounds (VOC) by purge and trap and gas chromatography (GC/FID+ECD) and calculation of the sum of BTEX benzene ethylbenzene toluene m+p-xylene o-xylene sum of BTEX by calculation (calculated) Regulated area: Tests |
SOP č.76-1 (ČSN EN ISO 15009) | ||
| 75 | Drinking, ground, surface and waste water, leachates of solid materials and waste | Determination of polycyclic aromatic hydrocarbons (PAH) by HPLC with FLU and DAD detection and calculation of the sum of PAH naphthalene fluoranthene benzo(b)fluoranthene benzo(k)fluoranthene benzo(a)pyrene benzo(g,h,i)perylene indeno(1,2,3-c,d)pyrene phenanthrene anthracene pyrene chrysene benzo(a)anthracene acenaphthylene sum of PAH by calculation (calculated) Regulated area: Tests |
SOP č.77-1 (ČSN EN ISO 17993) | ||
| 76 | Solid matrices | Determination of polycyclic aromatic hydrocarbons (PAH) by HPLC with FLU and DAD detection and calculation of the sum of PAH naphthalene fluoranthene benzo(b)fluoranthene benzo(k)fluoranthene benzo(a)pyrene benzo(g,h,i)perylene indeno(1,2,3-c,d)pyrene phenanthrene anthracene pyrene chrysene benzo(a)anthracene acenaphthylene sum of PAH by calculation (calculated) Regulated area: Tests |
SOP č.78-1 (ČSN EN 17503) | ||
| 77 | Drinking, ground and surface water | Determination of selected analytes by liquid chromatography (LC/MS/MS) (negative/positive mode) and calculation of the sum of pesticides Regulated area: Tests |
SOP č.79-1 (EPA Method 535; EPA Method 536; aplikační listy firmy Agilent Technologies) | ||
| 78 | Drinking, ground and surface water | Determination of glyphosate and its metabolites after derivatisation by liquid chromatography (LC/MS/MS) glyphosate AMPA glufosinate-ammonium Regulated area: Tests |
SOP č.80-1 (ČSN ISO 21458; EPA Method 535; EPA Method 536) | ||
| 79 | Drinking, ground, surface and waste water, leachates of solid materials and waste | Determination of hydrocarbons C10 to C40 by gas chromatography (GC/FID) Regulated area: Tests |
SOP č.81-1 (ČSN EN ISO 9377-2) | ||
| 80 | Solid matrices | Determination of hydrocarbons C10 to C40 by gas chromatography (GC/FID) Regulated area: Tests |
SOP č.82-1 (ČSN EN 14039) | ||
| 81 | Drinking and surface water | Determination of microcystin-LR by liquid chromatography (LC/MS/MS) Regulated area: Tests |
SOP č.83-1 (ČSN ISO 20179, Příloha A) | ||
| 82 | Drinking, ground, surface and waste water, bathing water, leachates of solid materials and waste | Determination of organic carbon (TOC, DOC) with NDIR analyser Regulated area: Tests |
SOP č.84-1 (ČSN EN 1484) | ||
| 83 | Drinking, ground, surface and waste water | Coulometric determination of adsorbable organically bound halogens (AOX) Regulated area: Tests |
SOP č.85-1 (ČSN EN ISO 9562) | ||
| 84 | Solid matrices | Determination of adsorbable organically bound halogens (AOX) Regulated area: Tests |
SOP č.86-1 (DIN 38 414 - 18; ČSN EN 16166) | ||
| 85 | Drinking, ground and surface water | Determination of haloacetic acids by liquid chromatography (LC/MS/MS) and calculation of their sum bromoacetic acid (MBAA) dibromoacetic acid (DBAA) chloroacetic acid (MCAA) dichloroacetic acid (DCAA) trichloroacetic acid (TCAA) sum of haloacetic acids by calculation (calculated) Regulated area: Tests |
SOP č.87-1 (EPA Method 557) | ||
| 86 | Drinking, ground, surface and waste water, leachates of solid materials and waste | Determination of elements by ICP-MS, calculation of the sum of calcium and magnesium Barium (Ba) Beryllium (Be) Boron (B) Calcium (Ca) Magnesium (Mg) Potassium (K) Sodium (Na) Iron (Fe) Manganese (Mn) Aluminium (Al) Vanadium (V) Cobalt (Co) Copper (Cu) Lead (Pb) Zinc (Zn) Cadmium (Cd) Chromium (Cr) Nickel (Ni) Arsenic (As) Selenium (Se) Molybdenum (Mo) Silver (Ag) Antimony (Sb) Thallium (Tl) Tin (Sn) Phosphorus (P) Uranium (U) Regulated area: Tests |
SOP č.88-1 (ČSN EN ISO 17294-2) | ||
| 87 | Solid matrices | Determination of elements by ICP-MS Barium (Ba) Beryllium (Be) Boron (B) Calcium (Ca) Magnesium (Mg) Potassium (K) Sodium (Na) Iron (Fe) Manganese (Mn) Aluminium (Al) Vanadium (V) Cobalt (Co) Copper (Cu) Lead (Pb) Zinc (Zn) Cadmium (Cd) Chromium (Cr) Nickel (Ni) Arsenic (As) Selenium (Se) Molybdenum (Mo) Silver (Ag) Antimony (Sb) Thallium (Tl) Tin (Sn) Phosphorus (P) Uranium (U) Regulated area: Tests |
SOP č.89-1 (ČSN EN ISO 17294-2; ČSN EN 16171) | ||
| 88 | Drinking, ground, surface and waste water, leachates of solid materials and waste, solid matrices | Determination of total mercury with AMA 254 analyser Regulated area: Tests |
SOP č.90-1 (ČSN 75 7440) | ||
| 89 | Drinking, ground and surface water | Spectrophotometric determination of hexavalent chromium Regulated area: Tests |
SOP č.91-1 (ČSN ISO 11083) | ||
| 90 | Drinking, ground, surface and waste water | Determination of gross beta activity with a proportional counter Regulated area: Tests |
SOP č.92-1 (ČSN 75 7612) | ||
| 91 | Drinking, ground, surface and waste water | Determination of gross alpha activity with a proportional counter Regulated area: Tests |
SOP č.93-1 (ČSN 75 7611) | ||
| 92 | Drinking, ground, surface and waste water | Determination of gross alpha activity by scintillation Regulated area: Tests |
SOP č.94-1 (ČSN 75 7611) | ||
| 93 | Drinking, ground, surface and waste water | Determination of radium-226 by precipitation method with a scintillation detector Regulated area: Tests |
SOP č.95-1 (ČSN 75 7611) | ||
| 94 | Drinking, ground and surface water | Determination of radon-222 activity concentration by gamma measurement Regulated area: Tests |
SOP č.96-1 (ČSN 75 7624) | ||
| 95 | Drinking, hot and bottled water | Manual sampling of drinking water Regulated area: Sampling |
SP č.1 (ČSN EN ISO 5667-3; ČSN ISO 5667-5; ČSN EN ISO 5667-14; ČSN EN ISO 5667-16; ČSN EN ISO 19458; Vyhláška č. 252/2004 Sb.) | ||
| 96 | Waste water | Manual and automatic sampler sampling of waste water Regulated area: Sampling |
SP č.2 (ČSN EN ISO 5667-3; ČSN ISO 5667-10; ČSN EN ISO 5667-14; ČSN 75 7315) | ||
| 97 | Ground water | Static sampling of ground water Regulated area: Sampling |
SP č.3 (ČSN EN ISO 5667-3; ČSN ISO 5667-11; ČSN EN ISO 5667-14; ČSN EN ISO 5667-16; ČSN EN ISO 19458) | ||
| 98 | Surface water | Manual sampling of surface water Regulated area: Sampling |
SP č.4 (ČSN EN ISO 5667-3; ČSN ISO 5667-4; ČSN EN ISO 5667-6; ČSN EN ISO 5667-14; ČSN EN ISO 5667-16; ČSN EN ISO 19458) | ||
| 99 | Bathing water | Manual sampling of bathing water Regulated area: Sampling |
SP č.9 (Vyhláška č. 238/2011 Sb.; ČSN EN ISO 19458) | ||
| 100 | Sewage and waterworks sludges, sands, screenings, suspended sediments, river sediments | Manual sampling of solid matrices Regulated area: Sampling |
SP č.8 (ČSN ISO 5667-12; ČSN EN ISO 5667-13; ČSN EN ISO 5667-15) | ||
| Workplace Boskovice | |||||
| 101 | Drinking, ground, surface and waste water, bathing water | Determination of pH by potentiometry Regulated area: Tests |
SOP č.1 (ČSN ISO 10523) | ||
| 102 | Drinking, ground and surface water | Determination of electrical conductivity Regulated area: Tests |
SOP č.3 (ČSN EN 27888) | ||
| 103 | Surface and waste water | Gravimetric determination of dissolved and total solids, loss on ignition and dissolved inorganic salts (RAS) Regulated area: Tests |
SOP č.6 (ČSN 75 7346; ČSN 75 7347) | ||
| 104 | Surface and waste water | Gravimetric determination of suspended solids and loss on ignition Regulated area: Tests |
SOP č.7 (ČSN EN 872; ČSN 75 7350) | ||
| 105 | Solid matrices | Gravimetric determination of total solids (dry matter) and water content Regulated area: Tests |
SOP č.8 (ČSN EN 15934) | ||
| 106 | Solid matrices | Gravimetric determination of loss on ignition Regulated area: Tests |
SOP č.9 (ČSN EN 15935) | ||
| 107 | Drinking, ground and surface water | Titrimetric determination of chemical oxygen demand with permanganate (CODMn) Regulated area: Tests |
SOP č.10 (ČSN EN ISO 8467) | ||
| 108 | Waste water | Spectrophotometric determination of chemical oxygen demand with dichromate (CODCr) using HACH test kit Regulated area: Tests |
SOP č.11 (ČSN ISO 15705; návod firmy HACH) | ||
| 109 | Ground, surface and waste water | Determination of biochemical oxygen demand after 5 days (BOD5) with LDO probe Regulated area: Tests |
SOP č.12 (ČSN EN ISO 5815-1; ČSN EN 1899-2) | ||
| 110 | Drinking, ground, surface and waste water | Spectrophotometric determination of ammonium ions and ammonia nitrogen Regulated area: Tests |
SOP č.13 (ČSN ISO 7150-1) | ||
| 111 | Drinking, ground, surface and waste water | Spectrophotometric determination of nitrite and nitrite nitrogen Regulated area: Tests |
SOP č.14 (ČSN EN 26777) | ||
| 112 | Drinking, ground, surface and waste water, bathing water | Spectrophotometric determination of nitrate and nitrate nitrogen and calculation of inorganic nitrogen from measured values Regulated area: Tests |
SOP č.15 (ČSN ISO 7890-3) | ||
| 113 | Drinking, ground and surface water | Titrimetric determination of chloride Regulated area: Tests |
SOP č.17 (ČSN ISO 9297) | ||
| 114 | Drinking, ground, surface and waste water | Spectrophotometric determination of nitrate nitrogen using HACH test kit and calculation of nitrate from measured values Regulated area: Tests |
SOP č.19 (návod firmy HACH) | ||
| 115 | Drinking, ground, surface and waste water | Spectrophotometric determination of nitrite nitrogen using HACH test kit and calculation of nitrite from measured values Regulated area: Tests |
SOP č.20 (návod firmy HACH) | ||
| 116 | Drinking, ground and surface water | Titrimetric determination of acid neutralising capacity (ANC) Regulated area: Tests |
SOP č.22 (ČSN EN ISO 9963-1) | ||
| 117 | Drinking, ground and surface water | Titrimetric determination of base neutralising capacity (BNC) Regulated area: Tests |
SOP č.23 (ČSN 75 7372) | ||
| 118 | Drinking, ground and surface water, bathing water | Determination of turbidity by nephelometry Regulated area: Tests |
SOP č.24 (ČSN EN ISO 7027-1) | ||
| 119 | Drinking, ground and surface water, bathing water | Spectrophotometric determination of colour by measuring absorbance at 410 nm Regulated area: Tests |
SOP č.25 (ČSN EN ISO 7887; Metoda C) | ||
| 120 | Drinking water, bathing water | Spectrophotometric determination of free and total chlorine using HACH test kit and calculation of bound chlorine from measured values Regulated area: Tests |
SOP č.26 (ČSN EN ISO 7393-2; návod firmy HACH) | ||
| 121 | Drinking, ground, surface and waste water, bathing water | Measurement of temperature Regulated area: Tests |
SOP č.27 (ČSN 75 7342) | ||
| 122 | Drinking, ground and surface water | Preliminary sensory determination of odour and taste Regulated area: Tests |
SOP č.28 (ČSN EN 1622; ČSN 75 7340) | ||
| 123 | Drinking, ground, surface and waste water | Determination of dissolved oxygen by luminescence method with LDO probe Regulated area: Tests |
SOP č.29 (ČSN ISO 17289; návod firmy HACH) | ||
| 124 | Drinking, ground and surface water | Microscopic determination of abioseston Regulated area: Tests |
SOP č.55 (ČSN 75 7713) | ||
| 125 | Drinking, ground and surface water | Microscopic determination of bioseston Regulated area: Tests |
SOP č.56 (ČSN 75 7712) | ||
| 126 | Drinking, ground and surface water, bathing water | Enumeration of Escherichia coli and coliform bacteria by membrane filtration Regulated area: Tests |
SOP č.57 (ČSN EN ISO 9308-1) | ||
| 127 | Drinking, ground and surface water, bathing water | Enumeration of intestinal enterococci by membrane filtration Regulated area: Tests |
SOP č.59 (ČSN EN ISO 7899-2) | ||
| 128 | Drinking, ground and surface water, bathing water | Enumeration of culturable microorganisms by inoculation in a nutrient agar culture medium at 36 °C and 22 °C Regulated area: Tests |
SOP č.60 (ČSN EN ISO 6222) | ||
| 129 | Drinking, ground and surface water, bathing water | Enumeration of Escherichia coli and coliform bacteria by most probable number method with a commercial kit Regulated area: Tests |
SOP č.62 (ČSN EN ISO 9308-2; návod výrobce IDEXX, Xebios) | ||
| 130 | Drinking water, bathing water | Enumeration of Legionella by membrane filtration Regulated area: Tests |
SOP č.67 (ČSN EN ISO 11731) | ||
| 131 | Drinking, ground and surface water, bathing water | Enumeration of Staphylococcus aureus by membrane filtration Regulated area: Tests |
SOP č.68 (ČSN EN ISO 6888-1) | ||
| 132 | Drinking, ground and surface water, bathing water | Enumeration of Pseudomonas aeruginosa by membrane filtration Regulated area: Tests |
SOP č.69 (ČSN EN ISO 16266) | ||
| 133 | Drinking, ground and surface water | Enumeration of Clostridium perfringens by membrane filtration Regulated area: Tests |
SOP č.70 (ČSN EN ISO 14189) | ||
| 134 | Drinking, ground and surface water | Titrimetric determination of the sum of calcium and magnesium and calculation of magnesium Regulated area: Tests |
SOP č.97 (ČSN ISO 6059) | ||
| 135 | Drinking, ground and surface water | Spectrophotometric determination of manganese Regulated area: Tests |
SOP č.98 (ČSN ISO 6333; návod firmy MACHERY-NAGEL) | ||
| 136 | Drinking, ground and surface water | Spectrophotometric determination of iron Regulated area: Tests |
SOP č.99 (ČSN ISO 6332) | ||
| 137 | Drinking, ground and surface water | Spectrophotometric determination of aluminium Regulated area: Tests |
SOP č.100 (ČSN ISO 10566) | ||
| 138 | Drinking, ground and surface water | Titrimetric determination of sulphate with lead nitrate Regulated area: Tests |
SOP č.101 (ČSN 75 7477) | ||
| 139 | Drinking, ground, surface and waste water | Spectrophotometric determination of phosphate and total phosphorus Regulated area: Tests |
SOP č.102 (ČSN EN ISO 6878; návod firmy MERCK/HACH) | ||
| 140 | Waste water | Spectrophotometric determination of total nitrogen using HACH test kit Regulated area: Tests |
SOP č.103 (ČSN EN ISO 11905-1; návod firmy HACH) | ||
| 141 | Drinking, ground and surface water | Titrimetric determination of calcium Regulated area: Tests |
SOP č.110 (ČSN ISO 6058) | ||
| 142 | Drinking, hot and bottled water | Manual sampling of drinking water Regulated area: Sampling |
SP č.1 (ČSN EN ISO 5667-3; ČSN ISO 5667-5; ČSN EN ISO 5667-14; ČSN EN ISO 5667-16; ČSN EN ISO 19458; Vyhláška č. 252/2004 Sb.) | ||
| 143 | Waste water | Manual and automatic sampler sampling of waste water Regulated area: Sampling |
SP č.2 (ČSN EN ISO 5667-3; ČSN ISO 5667-10; ČSN EN ISO 5667-14; ČSN 75 7315) | ||
| 144 | Ground water | Static sampling of ground water Regulated area: Sampling |
SP č.3 (ČSN EN ISO 5667-3; ČSN ISO 5667-11; ČSN EN ISO 5667-14; ČSN EN ISO 5667-16; ČSN EN ISO 19458) | ||
| 145 | Surface water | Manual sampling of surface water Regulated area: Sampling |
SP č.4 (ČSN EN ISO 5667-3; ČSN ISO 5667-4; ČSN EN ISO 5667-6; ČSN EN ISO 5667-14; ČSN EN ISO 5667-16; ČSN EN ISO 19458) | ||
| 146 | Bathing water | Manual sampling of bathing water Regulated area: Sampling |
SP č.9 (Vyhláška č. 238/2011 Sb.; ČSN EN ISO 19458) | ||
| 147 | Sewage and waterworks sludges, sands, screenings, suspended sediments, river sediments | Manual sampling of solid matrices Regulated area: Sampling |
SP č.8 (ČSN ISO 5667-12; ČSN EN ISO 5667-13; ČSN EN ISO 5667-15) | ||
| Workplace Jihlava | |||||
| 148 | Drinking, ground, surface and waste water | Determination of pH by potentiometry Regulated area: Tests |
SOP č.1 (ČSN ISO 10523) | ||
| 149 | Drinking, ground and surface water | Determination of electrical conductivity Regulated area: Tests |
SOP č.3 (ČSN EN 27888) | ||
| 150 | Drinking, ground and surface water | Spectrophotometric determination of absorbance at 254 nm Regulated area: Tests |
SOP č.5 (ČSN 75 7360) | ||
| 151 | Ground, surface and waste water | Gravimetric determination of dissolved and total solids, loss on ignition and dissolved inorganic salts (RAS) Regulated area: Tests |
SOP č.6 (ČSN 75 7346; ČSN 75 7347) | ||
| 152 | Ground, surface and waste water | Gravimetric determination of suspended solids and loss on ignition Regulated area: Tests |
SOP č.7 (ČSN EN 872; ČSN 75 7350) | ||
| 153 | Drinking, ground and surface water | Titrimetric determination of chemical oxygen demand with permanganate (CODMn) Regulated area: Tests |
SOP č.10 (ČSN EN ISO 8467) | ||
| 154 | Drinking, ground, surface and waste water | Spectrophotometric determination of chemical oxygen demand with dichromate (CODCr) using MERCK test kit Regulated area: Tests |
SOP č.11 (ČSN ISO 15705; návod firmy MERCK) | ||
| 155 | Ground, surface and waste water | Determination of biochemical oxygen demand after 5 days (BOD5) with LDO probe Regulated area: Tests |
SOP č.12 (ČSN EN ISO 5815-1; ČSN EN 1899-2) | ||
| 156 | Drinking, ground and surface water | Spectrophotometric determination of ammonium ions and ammonia nitrogen Regulated area: Tests |
SOP č.13 (ČSN ISO 7150-1) | ||
| 157 | Drinking, ground, surface and waste water | Spectrophotometric determination of nitrite and nitrite nitrogen Regulated area: Tests |
SOP č.14 (ČSN EN 26777) | ||
| 158 | Drinking, ground, surface and waste water | Spectrophotometric determination of nitrate and nitrate nitrogen and calculation of inorganic nitrogen from measured values Regulated area: Tests |
SOP č.15 (ČSN ISO 7890-3) | ||
| 159 | Ground, surface and waste water | Spectrophotometric determination of nitrate nitrogen using MERCK test kit and calculation of nitrate from measured values Regulated area: Tests |
SOP č.19 (návod firmy MERCK) | ||
| 160 | Drinking, ground and surface water | Titrimetric determination of acid neutralising capacity (ANC) Regulated area: Tests |
SOP č.22 (ČSN EN ISO 9963-1) | ||
| 161 | Drinking, ground and surface water | Titrimetric determination of base neutralising capacity (BNC) Regulated area: Tests |
SOP č.23 (ČSN 75 7372) | ||
| 162 | Drinking, ground and surface water | Determination of turbidity by nephelometry Regulated area: Tests |
SOP č.24 (ČSN EN ISO 7027-1) | ||
| 163 | Drinking, ground and surface water | Spectrophotometric determination of colour by measuring absorbance at 410 nm Regulated area: Tests |
SOP č.25 (ČSN EN ISO 7887; Metoda C) | ||
| 164 | Drinking water | Spectrophotometric determination of free and total chlorine using HACH test kit and calculation of bound chlorine from measured values Regulated area: Tests |
SOP č.26 (ČSN EN ISO 7393-2; návod firmy HACH) | ||
| 165 | Drinking, ground, surface and waste water | Measurement of temperature Regulated area: Tests |
SOP č.27 (ČSN 75 7342) | ||
| 166 | Drinking, ground and surface water | Preliminary sensory determination of odour and taste Regulated area: Tests |
SOP č.28 (ČSN EN 1622; ČSN 75 7340) | ||
| 167 | Drinking, ground, surface and waste water | Determination of dissolved oxygen by luminescence method with LDO probe Regulated area: Tests |
SOP č.29 (ČSN ISO 17289; návod firmy HACH) | ||
| 168 | Drinking, ground and surface water | Spectrophotometric determination of humic substances Regulated area: Tests |
SOP č.33 (ČSN 75 7536) | ||
| 169 | Ground, surface and waste water | Gravimetric determination of extractable substances (EL) Regulated area: Tests |
SOP č.35 (ČSN 75 7508) | ||
| 170 | Drinking, ground, surface and waste water | Spectrophotometric determination of anionic surfactants using a test kit Regulated area: Tests |
SOP č.54 (návod firmy HACH a MERCK) | ||
| 171 | Drinking, ground and surface water | Microscopic determination of abioseston Regulated area: Tests |
SOP č.55 (ČSN 75 7713) | ||
| 172 | Drinking, ground and surface water | Microscopic determination of bioseston Regulated area: Tests |
SOP č.56 (ČSN 75 7712) | ||
| 173 | Drinking, ground and surface water | Enumeration of Escherichia coli and coliform bacteria by membrane filtration Regulated area: Tests |
SOP č.57 (ČSN EN ISO 9308-1) | ||
| 174 | Drinking, ground and surface water | Enumeration of thermotolerant coliform bacteria and Escherichia coli by membrane filtration Regulated area: Tests |
SOP č.58 (ČSN 75 7835) | ||
| 175 | Drinking, ground and surface water | Enumeration of intestinal enterococci by membrane filtration Regulated area: Tests |
SOP č.59 (ČSN EN ISO 7899-2) | ||
| 176 | Drinking, ground and surface water | Enumeration of culturable microorganisms by inoculation in a nutrient agar culture medium at 36 °C and 22 °C Regulated area: Tests |
SOP č.60 (ČSN EN ISO 6222) | ||
| 177 | Drinking, ground and surface water | Enumeration of Clostridium perfringens by membrane filtration Regulated area: Tests |
SOP č.61 (Vyhláška č.252/2004 Sb.; Vyhláška č.70/2018 Sb.) | ||
| 178 | Drinking, ground and surface water | Enumeration of Escherichia coli and coliform bacteria by most probable number method with a commercial kit Regulated area: Tests |
SOP č.62 (ČSN EN ISO 9308-2; návod výrobce IDEXX, Xebios) | ||
| 179 | Drinking, ground and surface water | Enumeration of Clostridium perfringens by membrane filtration Regulated area: Tests |
SOP č.70 (ČSN EN ISO 14189) | ||
| 180 | Drinking, ground and surface water | Spectrophotometric determination of manganese Regulated area: Tests |
SOP č.98 (ČSN ISO 6333; návod firmy MACHERY-NAGEL) | ||
| 181 | Drinking, ground and surface water | Spectrophotometric determination of iron Regulated area: Tests |
SOP č.99 (ČSN ISO 6332) | ||
| 182 | Drinking, ground, surface and waste water | Spectrophotometric determination of phosphate and total phosphorus Regulated area: Tests |
SOP č.102 (ČSN EN ISO 6878; návod firmy MERCK) | ||
| 183 | Drinking, ground, surface and waste water | Spectrophotometric determination of total nitrogen using MERCK test kit Regulated area: Tests |
SOP č.103 (ČSN EN ISO 11905-1; návod firmy MERCK) | ||
| 184 | Surface and waste water | Titrimetric determination of ammonium ions and calculation of ammonia nitrogen and inorganic nitrogen Regulated area: Tests |
SOP č.104 (ČSN ISO 5664) | ||
| 185 | Drinking, ground, surface and waste water | Spectrophotometric determination of total phosphorus using MERCK test kit Regulated area: Tests |
SOP č.105 (návod firmy MERCK) | ||
| 186 | Drinking, ground and surface water | Determination of nitrate by UV spectrophotometry Regulated area: Tests |
SOP č.106 | ||
| 187 | Drinking, hot and bottled water | Manual sampling of drinking water Regulated area: Sampling |
SP č.1 (ČSN EN ISO 5667-3; ČSN ISO 5667-5; ČSN EN ISO 5667-14; ČSN EN ISO 5667-16; ČSN EN ISO 19458; Vyhláška č. 252/2004 Sb.) | ||
| 188 | Waste water | Manual and automatic sampler sampling of waste water Regulated area: Sampling |
SP č.2 (ČSN EN ISO 5667-3; ČSN ISO 5667-10; ČSN EN ISO 5667-14; ČSN 75 7315) | ||
| 189 | Ground water | Static sampling of ground water Regulated area: Sampling |
SP č.3 (ČSN EN ISO 5667-3; ČSN ISO 5667-11; ČSN EN ISO 5667-14; ČSN EN ISO 5667-16; ČSN EN ISO 19458) | ||
| 190 | Surface water | Manual sampling of surface water Regulated area: Sampling |
SP č.4 (ČSN EN ISO 5667-3; ČSN ISO 5667-4; ČSN EN ISO 5667-6; ČSN EN ISO 5667-14; ČSN EN ISO 5667-16; ČSN EN ISO 19458) | ||
| 191 | Sewage and waterworks sludges, sands, screenings, suspended sediments, river sediments | Manual sampling of solid matrices Regulated area: Sampling |
SP č.8 (ČSN ISO 5667-12; ČSN EN ISO 5667-13; ČSN EN ISO 5667-15) | ||
| Workplace Třebíč – drinking water laboratory | |||||
| 192 | Drinking, ground and surface water | Determination of pH by potentiometry Regulated area: Tests |
SOP č.1 (ČSN ISO 10523) | ||
| 193 | Drinking, ground and surface water | Spectrophotometric determination of absorbance at 254 nm Regulated area: Tests |
SOP č.5 (ČSN 75 7360) | ||
| 194 | Drinking, ground and surface water | Titrimetric determination of chemical oxygen demand with permanganate (CODMn) Regulated area: Tests |
SOP č.10 (ČSN EN ISO 8467) | ||
| 195 | Drinking, ground and surface water | Titrimetric determination of base neutralising capacity (BNC) Regulated area: Tests |
SOP č.23 (ČSN 75 7372) | ||
| 196 | Drinking, ground and surface water | Determination of turbidity by nephelometry Regulated area: Tests |
SOP č.24 (ČSN EN ISO 7027-1) | ||
| 197 | Drinking water | Spectrophotometric determination of free and total chlorine using HACH test kit and calculation of bound chlorine from measured values Regulated area: Tests |
SOP č.26 (ČSN EN ISO 7393-2; návod firmy HACH) | ||
| 198 | Drinking, ground and surface water | Measurement of water temperature Regulated area: Tests |
SOP č.27 (ČSN 75 7342) | ||
| 199 | Drinking, ground and surface water | Preliminary sensory determination of odour and taste Regulated area: Tests |
SOP č.28 (ČSN EN 1622; ČSN 75 7340) | ||
| 200 | Drinking, ground and surface water | Determination of dissolved oxygen by luminescence method with LDO probe Regulated area: Tests |
SOP č.29 (ČSN ISO 17289; návod firmy HACH) | ||
| 201 | Drinking, ground and surface water | Spectrophotometric determination of humic substances Regulated area: Tests |
SOP č.33 (ČSN 75 7536) | ||
| 202 | Drinking, ground and surface water | Determination of pH by potentiometry with Gallery automatic analyser Regulated area: Tests |
SOP č.37 (návod firmy Thermo Scientific) | ||
| 203 | Drinking, ground and surface water | Determination of electrical conductivity with Gallery automatic analyser Regulated area: Tests |
SOP č.38 (návod firmy Thermo Scientific) | ||
| 204 | Drinking, ground and surface water | Spectrophotometric determination of ammonium ions with Gallery automatic analyser Regulated area: Tests |
SOP č.39 (návod firmy Thermo Scientific) | ||
| 205 | Drinking, ground and surface water | Spectrophotometric determination of nitrate with Gallery automatic analyser Regulated area: Tests |
SOP č.40 (návod firmy Thermo Scientific) | ||
| 206 | Drinking, ground and surface water | Spectrophotometric determination of nitrite with Gallery automatic analyser Regulated area: Tests |
SOP č.41 (návod firmy Thermo Scientific) | ||
| 207 | Drinking, ground and surface water | Spectrophotometric determination of phosphate with Gallery automatic analyser Regulated area: Tests |
SOP č.42 (návod firmy Thermo Scientific) | ||
| 208 | Drinking, ground and surface water | Spectrophotometric determination of chloride with Gallery automatic analyser Regulated area: Tests |
SOP č.43 (návod firmy Thermo Scientific) | ||
| 209 | Drinking, ground and surface water | Spectrophotometric determination of sulphate with Gallery automatic analyser Regulated area: Tests |
SOP č.44 (návod firmy Thermo Scientific) | ||
| 210 | Drinking, ground and surface water | Spectrophotometric determination of acid neutralising capacity (ANC) with Gallery automatic analyser Regulated area: Tests |
SOP č.45 (návod firmy Thermo Scientific) | ||
| 211 | Drinking, ground and surface water | Spectrophotometric determination of colour with Gallery automatic analyser Regulated area: Tests |
SOP č.46 (návod firmy Thermo Scientific) | ||
| 212 | Drinking, ground and surface water | Spectrophotometric determination of calcium with Gallery automatic analyser and calculation of the sum of calcium and magnesium Regulated area: Tests |
SOP č.47 (návod firmy Thermo Scientific) | ||
| 213 | Drinking, ground and surface water | Spectrophotometric determination of magnesium with Gallery automatic analyser and calculation of the sum of calcium and magnesium Regulated area: Tests |
SOP č.48 (návod firmy Thermo Scientific) | ||
| 214 | Drinking, ground and surface water | Spectrophotometric determination of iron with Gallery automatic analyser Regulated area: Tests |
SOP č.49 (návod firmy Thermo Scientific) | ||
| 215 | Drinking, ground and surface water | Spectrophotometric determination of manganese with Gallery automatic analyser Regulated area: Tests |
SOP č.50 (návod firmy Thermo Scientific) | ||
| 216 | Drinking, ground and surface water | Spectrophotometric determination of aluminium with Gallery automatic analyser Regulated area: Tests |
SOP č.51 (návod firmy Thermo Scientific) | ||
| 217 | Drinking, ground and surface water | Microscopic determination of abioseston Regulated area: Tests |
SOP č.55 (ČSN 75 7713) | ||
| 218 | Drinking, ground and surface water | Microscopic determination of bioseston Regulated area: Tests |
SOP č.56 (ČSN 75 7712) | ||
| 219 | Drinking, ground and surface water | Enumeration of Escherichia coli and coliform bacteria by membrane filtration Regulated area: Tests |
SOP č.57 (ČSN EN ISO 9308-1) | ||
| 220 | Drinking, ground and surface water | Enumeration of thermotolerant coliform bacteria and Escherichia coli by membrane filtration Regulated area: Tests |
SOP č.58 (ČSN 75 7835) | ||
| 221 | Drinking, ground and surface water | Enumeration of intestinal enterococci by membrane filtration Regulated area: Tests |
SOP č.59 (ČSN EN ISO 7899-2) | ||
| 222 | Drinking, ground and surface water | Enumeration of culturable microorganisms by inoculation in a nutrient agar culture medium at 36 °C and 22 °C Regulated area: Tests |
SOP č.60 (ČSN EN ISO 6222) | ||
| 223 | Drinking, ground and surface water | Enumeration of Clostridium perfringens by membrane filtration Regulated area: Tests |
SOP č.61 (Vyhláška č.252/2004 Sb.; Vyhláška č.70/2018 Sb.) | ||
| 224 | Drinking, ground and surface water | Enumeration of Escherichia coli and coliform bacteria by most probable number method with a commercial kit Regulated area: Tests |
SOP č.62 (ČSN EN ISO 9308-2; návod výrobce IDEXX, Xebios) | ||
| 225 | Drinking, ground and surface water | Enumeration of Clostridium perfringens by membrane filtration Regulated area: Tests |
SOP č.70 (ČSN EN ISO 14189) | ||
| 226 | Drinking, ground and surface water | Determination of nitrate by UV spectrophotometry Regulated area: Tests |
SOP č.106 | ||
| 227 | Drinking, hot and bottled water | Manual sampling of drinking water Regulated area: Sampling |
SP č.1 (ČSN EN ISO 5667-3; ČSN ISO 5667-5; ČSN EN ISO 5667-14; ČSN EN ISO 5667-16; ČSN EN ISO 19458; Vyhláška č. 252/2004 Sb.) | ||
| 228 | Ground water | Static sampling of ground water Regulated area: Sampling |
SP č.3 (ČSN EN ISO 5667-3; ČSN ISO 5667-11; ČSN EN ISO 5667-14; ČSN EN ISO 5667-16; ČSN EN ISO 19458) | ||
| 229 | Surface water | Manual sampling of surface water Regulated area: Sampling |
SP č.4 (ČSN EN ISO 5667-3; ČSN ISO 5667-4; ČSN EN ISO 5667-6; ČSN EN ISO 5667-14; ČSN EN ISO 5667-16; ČSN EN ISO 19458) | ||
| Workplace Třebíč – waste water laboratory | |||||
| 230 | Surface and waste water | Determination of pH by potentiometry Regulated area: Tests |
SOP č.1 (ČSN ISO 10523) | ||
| 231 | Surface and waste water | Gravimetric determination of dissolved and total solids, loss on ignition and dissolved inorganic salts (RAS) Regulated area: Tests |
SOP č.6 (ČSN 75 7346; ČSN 75 7347) | ||
| 232 | Drinking, ground, surface and waste water | Gravimetric determination of suspended solids and loss on ignition Regulated area: Tests |
SOP č.7 (ČSN EN 872; ČSN 75 7350) | ||
| 233 | Drinking, ground, surface and waste water | Spectrophotometric determination of chemical oxygen demand with dichromate (CODCr) using HACH test kit Regulated area: Tests |
SOP č.11 (ČSN ISO 15705; návod firmy HACH) | ||
| 234 | Drinking, ground, surface and waste water | Determination of biochemical oxygen demand after 5 days (BOD5) with LDO probe Regulated area: Tests |
SOP č.12 (ČSN EN ISO 5815-1; ČSN EN 1899-2) | ||
| 235 | Surface and waste water | Spectrophotometric determination of nitrate nitrogen using HACH test kit and calculation of nitrate from measured values Regulated area: Tests |
SOP č.19 (návod firmy HACH) | ||
| 236 | Surface and waste water | Spectrophotometric determination of nitrite nitrogen using HACH test kit and calculation of nitrite from measured values Regulated area: Tests |
SOP č.20 (návod firmy HACH) | ||
| 237 | Surface and waste water | Measurement of temperature Regulated area: Tests |
SOP č.27 (ČSN 75 7342) | ||
| 238 | Drinking, ground, surface and waste water | Determination of dissolved oxygen by luminescence method with LDO probe Regulated area: Tests |
SOP č.29 (ČSN ISO 17289; návod firmy HACH) | ||
| 239 | Drinking, ground, surface and waste water | Spectrophotometric determination of total nitrogen using HACH test kit Regulated area: Tests |
SOP č.103 (ČSN EN ISO 11905-1; návod firmy HACH) | ||
| 240 | Surface and waste water | Titrimetric determination of ammonium ions and calculation of ammonia nitrogen and inorganic nitrogen Regulated area: Tests |
SOP č.104 (ČSN ISO 5664) | ||
| 241 | Surface and waste water | Spectrophotometric determination of total phosphorus using HACH test kit Regulated area: Tests |
SOP č.105 (návod firmy HACH) | ||
| 242 | Waste water | Manual and automatic sampler sampling of waste water Regulated area: Sampling |
SP č.2 (ČSN EN ISO 5667-3; ČSN ISO 5667-10; ČSN EN ISO 5667-14; ČSN 75 7315) | ||
| 243 | Surface water | Manual sampling of surface water Regulated area: Sampling |
SP č.4 (ČSN EN ISO 5667-3; ČSN ISO 5667-4; ČSN EN ISO 5667-6; ČSN EN ISO 5667-14; ČSN EN ISO 5667-16; ČSN EN ISO 19458) | ||
| 244 | Sewage and waterworks sludges, sands, screenings, suspended sediments, river sediments | Manual sampling of solid matrices Regulated area: Sampling |
SP č.8 (ČSN ISO 5667-12; ČSN EN ISO 5667-13; ČSN EN ISO 5667-15) | ||
| Workplace Znojmo – drinking water laboratory | |||||
| 245 | Drinking, ground and surface water, bathing water | Determination of pH by potentiometry Regulated area: Tests |
SOP č.1 (ČSN ISO 10523) | ||
| 246 | Drinking, ground and surface water | Determination of electrical conductivity Regulated area: Tests |
SOP č.3 (ČSN EN 27888) | ||
| 247 | Drinking, ground and surface water | Spectrophotometric determination of absorbance at 254 nm Regulated area: Tests |
SOP č.5 (ČSN 75 7360) | ||
| 248 | Drinking, ground and surface water, bathing water | Titrimetric determination of chemical oxygen demand with permanganate (CODMn) Regulated area: Tests |
SOP č.10 (ČSN EN ISO 8467) | ||
| 249 | Drinking, ground and surface water, bathing water | Spectrophotometric determination of ammonium ions and ammonia nitrogen Regulated area: Tests |
SOP č.13 (ČSN ISO 7150-1) | ||
| 250 | Drinking, ground and surface water | Spectrophotometric determination of nitrite and nitrite nitrogen Regulated area: Tests |
SOP č.14 (ČSN EN 26777) | ||
| 251 | Drinking, ground and surface water | Titrimetric determination of acid neutralising capacity (ANC) Regulated area: Tests |
SOP č.22 (ČSN EN ISO 9963-1) | ||
| 252 | Drinking, ground and surface water | Titrimetric determination of base neutralising capacity (BNC) Regulated area: Tests |
SOP č.23 (ČSN 75 7372) | ||
| 253 | Drinking, ground and surface water, bathing water | Determination of turbidity by nephelometry Regulated area: Tests |
SOP č.24 (ČSN EN ISO 7027-1) | ||
| 254 | Drinking, ground and surface water | Spectrophotometric determination of colour by measuring absorbance at 410 nm Regulated area: Tests |
SOP č.25 (ČSN EN ISO 7887; Metoda C) | ||
| 255 | Drinking water, bathing water | Spectrophotometric determination of free and total chlorine using HACH test kit and calculation of bound chlorine from measured values Regulated area: Tests |
SOP č.26 (ČSN EN ISO 7393-2; návod firmy HACH) | ||
| 256 | Drinking, ground and surface water, bathing water | Measurement of temperature Regulated area: Tests |
SOP č.27 (ČSN 75 7342) | ||
| 257 | Drinking, ground and surface water | Preliminary sensory determination of odour and taste Regulated area: Tests |
SOP č.28 (ČSN EN 1622; ČSN 75 7340) | ||
| 258 | Drinking, ground and surface water, bathing water | Determination of dissolved oxygen by luminescence method with LDO probe Regulated area: Tests |
SOP č.29 (ČSN ISO 17289; návod firmy HACH) | ||
| 259 | Drinking, ground and surface water | Spectrophotometric determination of humic substances Regulated area: Tests |
SOP č.33 (ČSN 75 7536) | ||
| 260 | Drinking, ground and surface water | Microscopic determination of abioseston Regulated area: Tests |
SOP č.55 (ČSN 75 7713) | ||
| 261 | Drinking, ground and surface water | Microscopic determination of bioseston Regulated area: Tests |
SOP č.56 (ČSN 75 7712) | ||
| 262 | Drinking, ground and surface water, bathing water | Enumeration of Escherichia coli and coliform bacteria by membrane filtration Regulated area: Tests |
SOP č.57 (ČSN EN ISO 9308-1) | ||
| 263 | Drinking, ground and surface water | Enumeration of thermotolerant coliform bacteria and Escherichia coli by membrane filtration Regulated area: Tests |
SOP č.58 (ČSN 75 7835) | ||
| 264 | Drinking, ground and surface water | Enumeration of intestinal enterococci by membrane filtration Regulated area: Tests |
SOP č.59 (ČSN EN ISO 7899-2) | ||
| 265 | Drinking, ground and surface water, bathing water | Enumeration of culturable microorganisms by inoculation in a nutrient agar culture medium at 36 °C and 22 °C Regulated area: Tests |
SOP č.60 (ČSN EN ISO 6222) | ||
| 266 | Drinking, ground and surface water, bathing water | Enumeration of Escherichia coli and coliform bacteria by most probable number method with a commercial kit Regulated area: Tests |
SOP č.62 (ČSN EN ISO 9308-2; návod výrobce IDEXX, Xebios) | ||
| 267 | Drinking water, bathing water | Enumeration of Legionella by membrane filtration Regulated area: Tests |
SOP č.67 (ČSN EN ISO 11731) | ||
| 268 | Drinking, ground and surface water, bathing water | Enumeration of Staphylococcus aureus by membrane filtration Regulated area: Tests |
SOP č.68 (ČSN EN ISO 6888-1) | ||
| 269 | Drinking, ground and surface water, bathing water | Enumeration of Pseudomonas aeruginosa by membrane filtration Regulated area: Tests |
SOP č.69 (ČSN EN ISO 16266) | ||
| 270 | Drinking, ground and surface water | Enumeration of Clostridium perfringens by membrane filtration Regulated area: Tests |
SOP č.70 (ČSN EN ISO 14189) | ||
| 271 | Drinking, ground and surface water | Titrimetric determination of the sum of calcium and magnesium and calculation of magnesium Regulated area: Tests |
SOP č.97 (ČSN ISO 6059) | ||
| 272 | Drinking, ground and surface water | Spectrophotometric determination of manganese Regulated area: Tests |
SOP č.98 (ČSN ISO 6333; návod firmy MACHERY-NAGEL) | ||
| 273 | Drinking, ground and surface water | Spectrophotometric determination of iron Regulated area: Tests |
SOP č.99 (ČSN ISO 6332) | ||
| 274 | Drinking, ground and surface water, bathing water | Determination of nitrate by UV spectrophotometry Regulated area: Tests |
SOP č.106 | ||
| 275 | Drinking water, bathing water | Spectrophotometric determination of ozone with HACH set Regulated area: Tests |
SOP č.108-6 (návod firmy HACH) | ||
| 276 | Drinking, ground and surface water | Titrimetric determination of calcium Regulated area: Tests |
SOP č.110 (ČSN ISO 6058) | ||
| 277 | Drinking, hot and bottled water | Manual sampling of drinking water Regulated area: Sampling |
SP č.1 (ČSN EN ISO 5667-3; ČSN ISO 5667-5; ČSN EN ISO 5667-14; ČSN EN ISO 5667-16; ČSN EN ISO 19458; Vyhláška č. 252/2004 Sb.) | ||
| 278 | Ground water | Static sampling of ground water Regulated area: Sampling |
SP č.3 (ČSN EN ISO 5667-3; ČSN ISO 5667-11; ČSN EN ISO 5667-14; ČSN EN ISO 5667-16; ČSN EN ISO 19458) | ||
| 279 | Surface water | Manual sampling of surface water Regulated area: Sampling |
SP č.4 (ČSN EN ISO 5667-3; ČSN ISO 5667-4; ČSN EN ISO 5667-6; ČSN EN ISO 5667-14; ČSN EN ISO 5667-16; ČSN EN ISO 19458) | ||
| 280 | Bathing water | Manual sampling of bathing water Regulated area: Sampling |
SP č.9 (Vyhláška č. 238/2011 Sb.; ČSN EN ISO 19458) | ||
| Workplace Znojmo – waste water laboratory | |||||
| 281 | Drinking, ground, surface and waste water | Determination of pH by potentiometry Regulated area: Tests |
SOP č.1 (ČSN ISO 10523) | ||
| 282 | Drinking, ground, surface and waste water | Gravimetric determination of dissolved and total solids, loss on ignition and dissolved inorganic salts (RAS) Regulated area: Tests |
SOP č.6 (ČSN 75 7346; ČSN 75 7347) | ||
| 283 | Surface and waste water | Gravimetric determination of suspended solids and loss on ignition Regulated area: Tests |
SOP č.7 (ČSN EN 872; ČSN 75 7350) | ||
| 284 | Drinking, ground, surface and waste water | Spectrophotometric determination of chemical oxygen demand with dichromate (CODCr) using HACH test kit Regulated area: Tests |
SOP č.11 (ČSN ISO 15705; návod firmy HACH) | ||
| 285 | Drinking, surface and waste water | Determination of biochemical oxygen demand after 5 days (BOD5) with LDO probe Regulated area: Tests |
SOP č.12 (ČSN EN ISO 5815-1; ČSN EN 1899-2) | ||
| 286 | Surface and waste water | Spectrophotometric determination of ammonium ions and ammonia nitrogen Regulated area: Tests |
SOP č.13 (ČSN ISO 7150-1) | ||
| 287 | Surface and waste water | Spectrophotometric determination of nitrite and nitrite nitrogen Regulated area: Tests |
SOP č.14 (ČSN EN 26777) | ||
| 288 | Surface and waste water | Spectrophotometric determination of nitrate nitrogen using HACH test kit and calculation of nitrate from measured values Regulated area: Tests |
SOP č.19 (návod firmy HACH) | ||
| 289 | Surface and waste water | Spectrophotometric determination of nitrite nitrogen using HACH test kit and calculation of nitrite from measured values Regulated area: Tests |
SOP č.20 (návod firmy HACH) | ||
| 290 | Drinking, ground, surface and waste water | Measurement of temperature Regulated area: Tests |
SOP č.27 (ČSN 75 7342) | ||
| 291 | Drinking, ground, surface and waste water | Determination of dissolved oxygen by luminescence method with LDO probe Regulated area: Tests |
SOP č.29 (ČSN ISO 17289; návod firmy HACH) | ||
| 292 | Surface and waste water | Spectrophotometric determination of total nitrogen using HACH test kit Regulated area: Tests |
SOP č.103 (ČSN EN ISO 11905-1; návod firmy HACH) | ||
| 293 | Surface and waste water | Spectrophotometric determination of total phosphorus using HACH test kit Regulated area: Tests |
SOP č.105 (návod firmy HACH) | ||
| 294 | Waste water | Manual and automatic sampler sampling of waste water Regulated area: Sampling |
SP č.2 (ČSN EN ISO 5667-3; ČSN ISO 5667-10; ČSN EN ISO 5667-14; ČSN 75 7315) | ||
| 295 | Sewage and waterworks sludges, sands, screenings, suspended sediments, river sediments | Manual sampling of solid matrices Regulated area: Sampling |
SP č.8 (ČSN ISO 5667-12; ČSN EN ISO 5667-13; ČSN EN ISO 5667-15) | ||
| Workplace Žďár nad Sázavou | |||||
| 296 | Drinking, ground, surface and waste water | Determination of pH by potentiometry Regulated area: Tests |
SOP č.1 (ČSN ISO 10523) | ||
| 297 | Drinking, ground and surface water | Determination of electrical conductivity Regulated area: Tests |
SOP č.3 (ČSN EN 27888) | ||
| 298 | Drinking, ground and surface water | Spectrophotometric determination of absorbance at 254 nm Regulated area: Tests |
SOP č.5 (ČSN 75 7360) | ||
| 299 | Drinking, ground, surface and waste water | Gravimetric determination of dissolved and total solids, loss on ignition and dissolved inorganic salts (RAS) Regulated area: Tests |
SOP č.6 (ČSN 75 7346; ČSN 75 7347) | ||
| 300 | Drinking, ground, surface and waste water | Gravimetric determination of suspended solids and loss on ignition Regulated area: Tests |
SOP č.7 (ČSN EN 872; ČSN 75 7350) | ||
| 301 | Solid matrices | Gravimetric determination of total solids (dry matter) and water content Regulated area: Tests |
SOP č.8 (ČSN EN 15934) | ||
| 302 | Solid matrices | Gravimetric determination of loss on ignition Regulated area: Tests |
SOP č.9 (ČSN EN 15935) | ||
| 303 | Drinking, ground and surface water | Titrimetric determination of chemical oxygen demand with permanganate (CODMn) Regulated area: Tests |
SOP č.10 (ČSN EN ISO 8467) | ||
| 304 | Drinking, ground, surface and waste water | Spectrophotometric determination of chemical oxygen demand with dichromate (CODCr) using HACH test kit Regulated area: Tests |
SOP č.11 (ČSN ISO 15705; návod firmy HACH) | ||
| 305 | Surface and waste water | Determination of biochemical oxygen demand after 5 days (BOD5) with LDO probe Regulated area: Tests |
SOP č.12 (ČSN EN ISO 5815-1; ČSN EN 1899-2) | ||
| 306 | Drinking, ground and surface water | Spectrophotometric determination of ammonium ions and ammonia nitrogen Regulated area: Tests |
SOP č.13 (ČSN ISO 7150-1) | ||
| 307 | Drinking, ground, surface and waste water | Spectrophotometric determination of nitrite and nitrite nitrogen Regulated area: Tests |
SOP č.14 (ČSN EN 26777) | ||
| 308 | Drinking, ground, surface and waste water | Spectrophotometric determination of nitrate and nitrate nitrogen and calculation of inorganic nitrogen from measured values Regulated area: Tests |
SOP č.15 (ČSN ISO 7890-3) | ||
| 309 | Drinking, ground and surface water | Titrimetric determination of chloride Regulated area: Tests |
SOP č.17 (ČSN ISO 9297) | ||
| 310 | Drinking, ground and surface water | Titrimetric determination of acid neutralising capacity (ANC) Regulated area: Tests |
SOP č.22 (ČSN EN ISO 9963-1) | ||
| 311 | Drinking, ground, surface and waste water | Titrimetric determination of base neutralising capacity (BNC) Regulated area: Tests |
SOP č.23 (ČSN 75 7372) | ||
| 312 | Drinking, ground and surface water | Determination of turbidity by nephelometry Regulated area: Tests |
SOP č.24 (ČSN EN ISO 7027-1) | ||
| 313 | Drinking, ground and surface water | Spectrophotometric determination of colour by measuring absorbance at 410 nm Regulated area: Tests |
SOP č.25 (ČSN EN ISO 7887; Metoda C) | ||
| 314 | Drinking water | Spectrophotometric determination of free and total chlorine using HACH test kit and calculation of bound chlorine from measured values Regulated area: Tests |
SOP č.26 (ČSN EN ISO 7393-2; návod firmy HACH) | ||
| 315 | Drinking, ground, surface and waste water | Measurement of temperature Regulated area: Tests |
SOP č.27 (ČSN 75 7342) | ||
| 316 | Drinking, ground and surface water | Preliminary sensory determination of odour and taste Regulated area: Tests |
SOP č.28 (ČSN EN 1622; ČSN 75 7340) | ||
| 317 | Drinking, ground, surface and waste water | Determination of dissolved oxygen by luminescence method with LDO probe Regulated area: Tests |
SOP č.29 (ČSN ISO 17289; návod firmy HACH) | ||
| 318 | Drinking, ground and surface water | Microscopic determination of abioseston Regulated area: Tests |
SOP č.55 (ČSN 75 7713) | ||
| 319 | Drinking, ground and surface water | Microscopic determination of bioseston Regulated area: Tests |
SOP č.56 (ČSN 75 7712) | ||
| 320 | Drinking, ground and surface water | Enumeration of Escherichia coli and coliform bacteria by membrane filtration Regulated area: Tests |
SOP č.57 (ČSN EN ISO 9308-1) | ||
| 321 | Drinking, ground and surface water | Enumeration of thermotolerant coliform bacteria and Escherichia coli by membrane filtration Regulated area: Tests |
SOP č.58 (ČSN 75 7835) | ||
| 322 | Drinking, ground and surface water | Enumeration of intestinal enterococci by membrane filtration Regulated area: Tests |
SOP č.59 (ČSN EN ISO 7899-2) | ||
| 323 | Drinking, ground and surface water | Enumeration of culturable microorganisms by inoculation in a nutrient agar culture medium at 36 °C and 22 °C Regulated area: Tests |
SOP č.60 (ČSN EN ISO 6222) | ||
| 324 | Drinking, ground and surface water | Enumeration of Clostridium perfringens by membrane filtration Regulated area: Tests |
SOP č.61 (Vyhláška č.252/2004 Sb.; Vyhláška č.70/2018 Sb.) | ||
| 325 | Drinking, ground and surface water | Enumeration of Escherichia coli and coliform bacteria by most probable number method with a commercial kit Regulated area: Tests |
SOP č.62 (ČSN EN ISO 9308-2; návod výrobce IDEXX, Xebios) | ||
| 326 | Solid matrices | Enumeration of thermotolerant coliform bacteria by culture Regulated area: Tests |
SOP č.64 (ČSN 75 7835; AHEM č. 7/2001; AHEM č. 1/2008) | ||
| 327 | Solid matrices | Enumeration of intestinal enterococci by culture Regulated area: Tests |
SOP č.65 (ČSN EN ISO 7899-2; AHEM č. 7/2001; AHEM č. 1/2008) | ||
| 328 | Drinking, ground and surface water | Enumeration of Clostridium perfringens by membrane filtration Regulated area: Tests |
SOP č.70 (ČSN EN ISO 14189) | ||
| 329 | Drinking, ground and surface water | Titrimetric determination of the sum of calcium and magnesium and calculation of magnesium Regulated area: Tests |
SOP č.97 (ČSN ISO 6059) | ||
| 330 | Drinking, ground and surface water | Spectrophotometric determination of manganese Regulated area: Tests |
SOP č.98 (ČSN ISO 6333; návod firmy MACHERY-NAGEL) | ||
| 331 | Drinking, ground and surface water | Spectrophotometric determination of iron Regulated area: Tests |
SOP č.99 (ČSN ISO 6332) | ||
| 332 | Drinking, ground and surface water | Spectrophotometric determination of aluminium Regulated area: Tests |
SOP č.100 (ČSN ISO 10566) | ||
| 333 | Drinking, ground and surface water | Titrimetric determination of sulphate with lead nitrate Regulated area: Tests |
SOP č.101 (ČSN 75 7477) | ||
| 334 | Drinking, ground and surface water | Spectrophotometric determination of phosphate and total phosphorus Regulated area: Tests |
SOP č.102 (ČSN EN ISO 6878) | ||
| 335 | Drinking, ground, surface and waste water | Spectrophotometric determination of total nitrogen using HACH test kit Regulated area: Tests |
SOP č.103 (ČSN EN ISO 11905-1; návod firmy HACH) | ||
| 336 | Surface and waste water | Titrimetric determination of ammonium ions and calculation of ammonia nitrogen and inorganic nitrogen Regulated area: Tests |
SOP č.104 (ČSN ISO 5664) | ||
| 337 | Drinking, ground and surface water | Determination of nitrate by UV spectrophotometry Regulated area: Tests |
SOP č.106 | ||
| 338 | Drinking, ground and surface water | Titrimetric determination of calcium Regulated area: Tests |
SOP č.110 (ČSN ISO 6058) | ||
| 339 | Surface and waste water | Spectrophotometric determination of total phosphorus using HACH test kit Regulated area: Tests |
SOP č.105 (návod firmy HACH) | ||
| 340 | Drinking, hot and bottled water | Manual sampling of drinking water Regulated area: Sampling |
SP č.1 (ČSN EN ISO 5667-3; ČSN ISO 5667-5; ČSN EN ISO 5667-14; ČSN EN ISO 5667-16; ČSN EN ISO 19458; Vyhláška č. 252/2004 Sb.) | ||
| 341 | Waste water | Manual and automatic sampler sampling of waste water Regulated area: Sampling |
SP č.2 (ČSN EN ISO 5667-3; ČSN ISO 5667-10; ČSN EN ISO 5667-14; ČSN 75 7315) | ||
| 342 | Ground water | Static sampling of ground water Regulated area: Sampling |
SP č.3 (ČSN EN ISO 5667-3; ČSN ISO 5667-11; ČSN EN ISO 5667-14; ČSN EN ISO 5667-16; ČSN EN ISO 19458) | ||
| 343 | Surface water | Manual sampling of surface water Regulated area: Sampling |
SP č.4 (ČSN EN ISO 5667-3; ČSN ISO 5667-4; ČSN EN ISO 5667-6; ČSN EN ISO 5667-14; ČSN EN ISO 5667-16; ČSN EN ISO 19458) | ||
| 344 | Sewage and waterworks sludges, sands, screenings, suspended sediments, river sediments | Manual sampling of solid matrices Regulated area: Sampling |
SP č.8 (ČSN ISO 5667-12; ČSN EN ISO 5667-13; ČSN EN ISO 5667-15) | ||
Reference standards (232)
AHEM č. 1/2008
AHEM č. 7/2001
DIN 38 414 - 18
DIN 38414-20
EPA Method 535
EPA Method 536
EPA Method 557
Metoda C
SOP č.1
SOP č.10
SOP č.100
SOP č.101
SOP č.102
SOP č.103
SOP č.104
SOP č.105
SOP č.106
SOP č.108-6
SOP č.11
SOP č.110
SOP č.12
SOP č.13
SOP č.14
SOP č.15
SOP č.16-1
SOP č.17
SOP č.18-1
SOP č.19
SOP č.2-1
SOP č.20
SOP č.21-1
SOP č.22
SOP č.23
SOP č.24
SOP č.25
SOP č.26
SOP č.27
SOP č.28
SOP č.29
SOP č.3
SOP č.30-1
SOP č.31-1
SOP č.32-1
SOP č.33
SOP č.34-1
SOP č.35
SOP č.36-1
SOP č.37
SOP č.38
SOP č.39
SOP č.4-1
SOP č.40
SOP č.41
SOP č.42
SOP č.43
SOP č.44
SOP č.45
SOP č.46
SOP č.47
SOP č.48
SOP č.49
SOP č.5
SOP č.50
SOP č.51
SOP č.52-1
SOP č.53-1
SOP č.54
SOP č.55
SOP č.56
SOP č.57
SOP č.58
SOP č.59
SOP č.6
SOP č.60
SOP č.61
SOP č.62
SOP č.63-1
SOP č.64
SOP č.65
SOP č.66-1
SOP č.67
SOP č.68
SOP č.69
SOP č.7
SOP č.70
SOP č.71-1
SOP č.72-1
SOP č.73-1
SOP č.75-1
SOP č.76-1
SOP č.77-1
SOP č.78-1
SOP č.79-1
SOP č.8
SOP č.80-1
SOP č.81-1
SOP č.82-1
SOP č.83-1
SOP č.84-1
SOP č.85-1
SOP č.86-1
SOP č.87-1
SOP č.88-1
SOP č.89-1
SOP č.9
SOP č.90-1
SOP č.91-1
SOP č.92-1
SOP č.93-1
SOP č.94-1
SOP č.95-1
SOP č.96-1
SOP č.97
SOP č.98
SOP č.99
SP č.1
SP č.2
SP č.3
SP č.4
SP č.8
SP č.9
Vyhláška č. 238/2011 Sb.
Vyhláška č. 252/2004 Sb.
Vyhláška č.252/2004 Sb.
Vyhláška č.70/2018 Sb.
aplikační listy firmy Agilent Technologies
návod firmy HACH
návod firmy HACH a MERCK
návod firmy HACH, MERCK
návod firmy MACHERY-NAGEL
návod firmy MERCK
návod firmy MERCK/HACH
návod firmy Thermo Scientific
návod výrobce IDEXX, Xebios
ČSN 75 7315
ČSN 75 7340
ČSN 75 7342
ČSN 75 7346
ČSN 75 7347
ČSN 75 7350
ČSN 75 7360
ČSN 75 7372
ČSN 75 7415
ČSN 75 7440
ČSN 75 7477
ČSN 75 7508
ČSN 75 7536
ČSN 75 7611
ČSN 75 7612
ČSN 75 7624
ČSN 75 7712
ČSN 75 7713
ČSN 75 7835
ČSN EN 12457-4
ČSN EN 13342
ČSN EN 14039
ČSN EN 1484
ČSN EN 15934
ČSN EN 15935
ČSN EN 16166
ČSN EN 16171
ČSN EN 1622
ČSN EN 17322
ČSN EN 17503
ČSN EN 1899-2
ČSN EN 26777
ČSN EN 27888
ČSN EN 872
ČSN EN 903
ČSN EN ISO 10301
ČSN EN ISO 10304-1
ČSN EN ISO 10304-4
ČSN EN ISO 10390
ČSN EN ISO 11348-2
ČSN EN ISO 11348-3
ČSN EN ISO 11731
ČSN EN ISO 11905-1
ČSN EN ISO 14189
ČSN EN ISO 15009
ČSN EN ISO 15061
ČSN EN ISO 15680
ČSN EN ISO 16266
ČSN EN ISO 17294-2
ČSN EN ISO 17993
ČSN EN ISO 19458
ČSN EN ISO 20236
ČSN EN ISO 5667-13
ČSN EN ISO 5667-14
ČSN EN ISO 5667-15
ČSN EN ISO 5667-16
ČSN EN ISO 5667-3
ČSN EN ISO 5667-6
ČSN EN ISO 5815-1
ČSN EN ISO 6222
ČSN EN ISO 6468
ČSN EN ISO 6579-1
ČSN EN ISO 6878
ČSN EN ISO 6888-1
ČSN EN ISO 7027-1
ČSN EN ISO 7393-2
ČSN EN ISO 7887
ČSN EN ISO 7899-2
ČSN EN ISO 8467
ČSN EN ISO 9308-1
ČSN EN ISO 9308-2
ČSN EN ISO 9377-2
ČSN EN ISO 9562
ČSN EN ISO 9963-1
ČSN ISO 10359-1
ČSN ISO 10523
ČSN ISO 10530
ČSN ISO 10566
ČSN ISO 11083
ČSN ISO 15705
ČSN ISO 17289
ČSN ISO 19250
ČSN ISO 20179, Příloha A
ČSN ISO 21458
ČSN ISO 5664
ČSN ISO 5667-10
ČSN ISO 5667-11
ČSN ISO 5667-12
ČSN ISO 5667-4
ČSN ISO 5667-5
ČSN ISO 6058
ČSN ISO 6059
ČSN ISO 6332
ČSN ISO 6333
ČSN ISO 6439
ČSN ISO 7150-1
ČSN ISO 7890-3
ČSN ISO 9297