🇨🇿 VODÁRENSKÁ AKCIOVÁ SPOLEČNOST, a.s. PL

ČIA 1249 • Brno, Czech Republic • 344 methods

Water & wastewaterMicrobiologyEnvironment

VODÁRENSKÁ AKCIOVÁ SPOLEČNOST, a.s. is a laboratory accredited by ČIA under number 1249 (Brno, Czech Republic). Its accreditation scope covers 344 test methods in the following areas: Water & wastewater, Microbiology, Environment. Test objects include: Drinking, ground and surface water, Drinking, ground, surface and waste water, Drinking, ground and surface water, bathing water, Surface and waste water.

At a glance

  • Accreditation number: ČIA 1249
  • Methods in scope: 344
  • Types of test objects: 22
  • City: Brno, Czech Republic
  • Valid until: 26-03-2031
Accreditation number
1249
Accreditation body
ČIA
Address
Soběšická 151, Lesná, 638 00 Brno
City
Brno, Czech Republic
Division
Laboratoria Gospodarki Wodnej
Valid until
26-03-2031

What this laboratory tests (22)

Laboratory sections (8)

Laboratory locations

Certificate information

Certificate date
03.09.2026

Accreditation scope — test methods (344)

No. Test object Methodology / Parameters Technique Reference document
Workplace Brno
1 Drinking, ground, surface and waste water, bathing water, leachates of solid materials and waste Determination of pH by potentiometry
Regulated area: Tests
SOP č.1 (ČSN ISO 10523)
2 Solid matrices Determination of pH by potentiometry
Regulated area: Tests
SOP č.2-1 (ČSN EN ISO 10390)
3 Drinking, ground, surface and waste water, leachates of solid materials and waste Determination of electrical conductivity
Regulated area: Tests
SOP č.3 (ČSN EN 27888)
4 Drinking, ground, surface and waste water, leachates of solid materials and waste Determination of fluoride with an ion-selective electrode
Regulated area: Tests
SOP č.4-1 (ČSN ISO 10359-1)
5 Drinking, ground and surface water Spectrophotometric determination of absorbance at 254 nm
Regulated area: Tests
SOP č.5 (ČSN 75 7360)
6 Drinking, ground, surface and waste water, leachates of solid materials and waste Gravimetric determination of dissolved and total solids, loss on ignition and dissolved inorganic salts (RAS)
Regulated area: Tests
SOP č.6 (ČSN 75 7346; ČSN 75 7347)
7 Drinking, ground, surface and waste water, leachates of solid materials and waste Gravimetric determination of suspended solids and loss on ignition
Regulated area: Tests
SOP č.7 (ČSN EN 872; ČSN 75 7350)
8 Solid matrices Gravimetric determination of total solids (dry matter) and water content
Regulated area: Tests
SOP č.8 (ČSN EN 15934)
9 Solid matrices Gravimetric determination of loss on ignition
Regulated area: Tests
SOP č.9 (ČSN EN 15935)
10 Drinking, ground and surface water, bathing water Titrimetric determination of chemical oxygen demand with permanganate (CODMn)
Regulated area: Tests
SOP č.10 (ČSN EN ISO 8467)
11 Drinking, ground, surface and waste water, leachates of solid materials and waste Spectrophotometric determination of chemical oxygen demand with dichromate (CODCr) using HACH test kit
Regulated area: Tests
SOP č.11 (ČSN ISO 15705; návod firmy HACH)
12 Drinking, ground, surface and waste water Determination of biochemical oxygen demand after 5 days (BOD5) with LDO probe
Regulated area: Tests
SOP č.12 (ČSN EN ISO 5815-1; ČSN EN 1899-2)
13 Drinking, ground, surface and waste water, bathing water Spectrophotometric determination of ammonium ions and ammonia nitrogen
Regulated area: Tests
SOP č.13 (ČSN ISO 7150-1)
14 Drinking, ground, surface and waste water, leachates of solid materials and waste Spectrophotometric determination of nitrite and nitrite nitrogen
Regulated area: Tests
SOP č.14 (ČSN EN 26777)
15 Drinking, ground, surface and waste water, bathing water Spectrophotometric determination of nitrate and nitrate nitrogen and calculation of inorganic nitrogen from measured values
Regulated area: Tests
SOP č.15 (ČSN ISO 7890-3)
16 Solid matrices Spectrophotometric determination of organic nitrogen by Kjeldahl
Regulated area: Tests
SOP č.16-1 (ČSN EN 13342)
17 Drinking, ground, surface and waste water, leachates of solid materials and waste Titrimetric determination of chloride
Regulated area: Tests
SOP č.17 (ČSN ISO 9297)
18 Waste water, leachates of solid materials and waste Spectrophotometric determination of sulphate using HACH test kit
Regulated area: Tests
SOP č.18-1 (návod firmy HACH)
19 Surface and waste water Spectrophotometric determination of nitrate nitrogen using HACH test kit and calculation of nitrate from measured values
Regulated area: Tests
SOP č.19 (návod firmy HACH)
20 Surface and waste water Spectrophotometric determination of nitrite nitrogen using HACH test kit and calculation of nitrite from measured values
Regulated area: Tests
SOP č.20 (návod firmy HACH)
21 Drinking, ground, surface and waste water Spectrophotometric determination of dissolved sulphides using HACH test kit
Regulated area: Tests
SOP č.21-1 (ČSN ISO 10530; návod firmy HACH)
22 Drinking, ground and surface water Titrimetric determination of acid neutralising capacity (ANC)
Regulated area: Tests
SOP č.22 (ČSN EN ISO 9963-1)
23 Drinking, ground and surface water Titrimetric determination of base neutralising capacity (BNC)
Regulated area: Tests
SOP č.23 (ČSN 75 7372)
24 Drinking, ground and surface water, bathing water Determination of turbidity by nephelometry
Regulated area: Tests
SOP č.24 (ČSN EN ISO 7027-1)
25 Drinking, ground and surface water Spectrophotometric determination of colour by measuring absorbance at 410 nm
Regulated area: Tests
SOP č.25 (ČSN EN ISO 7887; Metoda C)
26 Drinking water, bathing water Spectrophotometric determination of free and total chlorine using HACH test kit and calculation of bound chlorine from measured values
Regulated area: Tests
SOP č.26 (ČSN EN ISO 7393-2; návod firmy HACH)
27 Drinking, ground, surface and waste water, bathing water Measurement of water temperature
Regulated area: Tests
SOP č.27 (ČSN 75 7342)
28 Drinking, ground and surface water Preliminary sensory determination of odour and taste
Regulated area: Tests
SOP č.28 (ČSN EN 1622; ČSN 75 7340)
29 Drinking, ground, surface and waste water, bathing water Determination of dissolved oxygen by luminescence method with LDO probe
Regulated area: Tests
SOP č.29 (ČSN ISO 17289; návod firmy HACH)
30 Drinking, ground, surface and waste water, leachates of solid materials and waste Determination of total nitrogen after oxidation to nitrogen oxides with TOC/TN analyser
Regulated area: Tests
SOP č.30-1 (ČSN EN ISO 20236)
31 Drinking, ground, surface and waste water, leachates of solid materials and waste Spectrophotometric determination of phenols after distillation
Regulated area: Tests
SOP č.31-1 (ČSN ISO 6439)
32 Drinking, ground, surface and waste water, leachates of solid materials and waste Spectrophotometric determination of cyanides after distillation
Regulated area: Tests
SOP č.32-1 (ČSN 75 7415)
33 Drinking, ground and surface water Spectrophotometric determination of humic substances
Regulated area: Tests
SOP č.33 (ČSN 75 7536)
34 Drinking, ground, surface and waste water, leachates of solid materials and waste Spectrophotometric determination of anionic surfactants
Regulated area: Tests
SOP č.34-1 (ČSN EN 903)
35 Ground, surface and waste water Gravimetric determination of extractable substances (EL)
Regulated area: Tests
SOP č.35 (ČSN 75 7508)
36 Drinking, ground and surface water, bathing water Determination of dissolved anions by ion chromatography with conductivity detection
fluorides chlorides nitrites nitrates sulphates phosphates chlorites chlorates bromates
sum of chlorites and chlorates by calculation (calculated)
Regulated area: Tests
SOP č.36-1 (ČSN EN ISO 10304-1; ČSN EN ISO 10304-4; ČSN EN ISO 15061)
37 Drinking, ground and surface water Determination of pH by potentiometry with Gallery automatic analyser
Regulated area: Tests
SOP č.37 (návod firmy Thermo Scientific)
38 Drinking, ground and surface water Determination of electrical conductivity with Gallery automatic analyser
Regulated area: Tests
SOP č.38 (návod firmy Thermo Scientific)
39 Drinking, ground and surface water Spectrophotometric determination of ammonium ions with Gallery automatic analyser
Regulated area: Tests
SOP č.39 (návod firmy Thermo Scientific)
40 Drinking, ground and surface water Spectrophotometric determination of nitrate with Gallery automatic analyser
Regulated area: Tests
SOP č.40 (návod firmy Thermo Scientific)
41 Drinking, ground and surface water Spectrophotometric determination of nitrite with Gallery automatic analyser
Regulated area: Tests
SOP č.41 (návod firmy Thermo Scientific)
42 Drinking, ground and surface water Spectrophotometric determination of phosphate with Gallery automatic analyser
Regulated area: Tests
SOP č.42 (návod firmy Thermo Scientific)
43 Drinking, ground and surface water Spectrophotometric determination of chloride with Gallery automatic analyser
Regulated area: Tests
SOP č.43 (návod firmy Thermo Scientific)
44 Drinking, ground and surface water Spectrophotometric determination of sulphate with Gallery automatic analyser
Regulated area: Tests
SOP č.44 (návod firmy Thermo Scientific)
45 Drinking, ground and surface water Spectrophotometric determination of acid neutralising capacity (ANC) with Gallery automatic analyser
Regulated area: Tests
SOP č.45 (návod firmy Thermo Scientific)
46 Drinking, ground and surface water Spectrophotometric determination of colour with Gallery automatic analyser
Regulated area: Tests
SOP č.46 (návod firmy Thermo Scientific)
47 Drinking, ground and surface water Spectrophotometric determination of calcium with Gallery automatic analyser and calculation of the sum of calcium and magnesium
Regulated area: Tests
SOP č.47 (návod firmy Thermo Scientific)
48 Drinking, ground and surface water Spectrophotometric determination of magnesium with Gallery automatic analyser and calculation of the sum of calcium and magnesium
Regulated area: Tests
SOP č.48 (návod firmy Thermo Scientific)
49 Drinking, ground and surface water Spectrophotometric determination of iron with Gallery automatic analyser
Regulated area: Tests
SOP č.49 (návod firmy Thermo Scientific)
50 Drinking, ground and surface water Spectrophotometric determination of manganese with Gallery automatic analyser
Regulated area: Tests
SOP č.50 (návod firmy Thermo Scientific)
51 Drinking, ground and surface water Spectrophotometric determination of aluminium with Gallery automatic analyser
Regulated area: Tests
SOP č.51 (návod firmy Thermo Scientific)
52 Aqueous leachates of solid materials and waste Spectrophotometric determination of nitrate and nitrate nitrogen
Regulated area: Tests
SOP č.52-1 (ČSN EN 12457-4; ČSN ISO 7890-3)
53 Aqueous leachates of solid materials and waste Spectrophotometric determination of ammonium ions and ammonia nitrogen
Regulated area: Tests
SOP č.53-1 (ČSN EN 12457-4; ČSN ISO 7150-1)
54 Drinking, ground, surface and waste water Spectrophotometric determination of anionic surfactants using a test kit
Regulated area: Tests
SOP č.54 (návod firmy HACH, MERCK)
55 Drinking, ground and surface water Microscopic determination of abioseston
Regulated area: Tests
SOP č.55 (ČSN 75 7713)
56 Drinking, ground and surface water Microscopic determination of bioseston
Regulated area: Tests
SOP č.56 (ČSN 75 7712)
57 Drinking, ground and surface water, bathing water Enumeration of Escherichia coli and coliform bacteria by membrane filtration
Regulated area: Tests
SOP č.57 (ČSN EN ISO 9308-1)
58 Drinking, ground and surface water Enumeration of thermotolerant coliform bacteria and Escherichia coli by membrane filtration
Regulated area: Tests
SOP č.58 (ČSN 75 7835)
59 Drinking, ground and surface water, bathing water Enumeration of intestinal enterococci by membrane filtration
Regulated area: Tests
SOP č.59 (ČSN EN ISO 7899-2)
60 Drinking, ground and surface water, bathing water Enumeration of culturable microorganisms by inoculation in a nutrient agar culture medium at 36 °C and 22 °C
Regulated area: Tests
SOP č.60 (ČSN EN ISO 6222)
61 Drinking, ground and surface water, bathing water Enumeration of Escherichia coli and coliform bacteria by most probable number method with a commercial kit
Regulated area: Tests
SOP č.62 (ČSN EN ISO 9308-2; návod výrobce IDEXX, Xebios)
62 Drinking, ground, surface and waste water Detection of Salmonella by culture
Regulated area: Tests
SOP č.63-1 (ČSN ISO 19250)
63 Solid matrices Enumeration of thermotolerant coliform bacteria by culture
Regulated area: Tests
SOP č.64 (ČSN 75 7835; AHEM č. 7/2001; AHEM č. 1/2008)
64 Solid matrices Enumeration of intestinal enterococci by culture
Regulated area: Tests
SOP č.65 (ČSN EN ISO 7899-2; AHEM č. 7/2001; AHEM č. 1/2008)
65 Solid matrices Detection of Salmonella by culture
Regulated area: Tests
SOP č.66-1 (ČSN EN ISO 6579-1; AHEM č. 7/2001; AHEM č. 1/2008)
66 Drinking water, bathing water Enumeration of Legionella by membrane filtration
Regulated area: Tests
SOP č.67 (ČSN EN ISO 11731)
67 Drinking, ground and surface water, bathing water Enumeration of Staphylococcus aureus by membrane filtration
Regulated area: Tests
SOP č.68 (ČSN EN ISO 6888-1)
68 Drinking, ground and surface water, bathing water Enumeration of Pseudomonas aeruginosa by membrane filtration
Regulated area: Tests
SOP č.69 (ČSN EN ISO 16266)
69 Drinking, ground and surface water Enumeration of Clostridium perfringens by membrane filtration
Regulated area: Tests
SOP č.70 (ČSN EN ISO 14189)
70 Drinking, ground, surface and waste water, leachates of solid materials and waste Determination of the inhibitory effect on the light emission of luminescent bacteria Aliivibrio fischeri
Regulated area: Tests
SOP č.71-1 (ČSN EN ISO 11348-2; ČSN EN ISO 11348-3)
71 Drinking, ground, surface and waste water, leachates of solid materials and waste Determination of polychlorinated biphenyls (PCB) by gas chromatography (GC/ECD) and calculation of the sum of PCB
PCB congeners 28, 52, 101, 118, 138, 153, 180
sum of PCB by calculation (calculated)
Regulated area: Tests
SOP č.72-1 (ČSN EN ISO 6468)
72 Solid matrices Determination of polychlorinated biphenyls (PCB) by gas chromatography (GC/ECD) and calculation of the sum of PCB
PCB congeners 28, 52, 101, 118, 138, 153, 180
sum of PCB by calculation (calculated)
Regulated area: Tests
SOP č.73-1 (DIN 38414-20; ČSN EN 17322)
73 Drinking, ground, surface and waste water, leachates of solid materials and waste Determination of volatile organic compounds (VOC) by purge and trap and gas chromatography (GC/FID+ECD) and calculation of the sum of trihalomethanes (THM)
1,1-dichloroethene o,m,p-dichlorobenzenes 1,2-dichloroethane cis-1,2-dichloroethene trans-1,2-dichloroethene benzene toluene o,m,p-xylenes styrene ethylbenzene chlorobenzene bromodichloromethane dibromochloromethane chloroform bromoform dichloromethane trichloroethene tetrachloroethene tetrachloromethane 1,1-dichloroethane 1,1,1-trichloroethane 1,2-dichloropropane 1,1,2-trichloroethane 1,1,2,2-tetrachloroethane
sum of trihalomethanes by calculation (calculated)
Regulated area: Tests
SOP č.75-1 (ČSN EN ISO 10301; ČSN EN ISO 15680)
74 Solid matrices Determination of volatile organic compounds (VOC) by purge and trap and gas chromatography (GC/FID+ECD) and calculation of the sum of BTEX
benzene ethylbenzene toluene m+p-xylene o-xylene
sum of BTEX by calculation (calculated)
Regulated area: Tests
SOP č.76-1 (ČSN EN ISO 15009)
75 Drinking, ground, surface and waste water, leachates of solid materials and waste Determination of polycyclic aromatic hydrocarbons (PAH) by HPLC with FLU and DAD detection and calculation of the sum of PAH
naphthalene fluoranthene benzo(b)fluoranthene benzo(k)fluoranthene benzo(a)pyrene benzo(g,h,i)perylene indeno(1,2,3-c,d)pyrene phenanthrene anthracene pyrene chrysene benzo(a)anthracene acenaphthylene
sum of PAH by calculation (calculated)
Regulated area: Tests
SOP č.77-1 (ČSN EN ISO 17993)
76 Solid matrices Determination of polycyclic aromatic hydrocarbons (PAH) by HPLC with FLU and DAD detection and calculation of the sum of PAH
naphthalene fluoranthene benzo(b)fluoranthene benzo(k)fluoranthene benzo(a)pyrene benzo(g,h,i)perylene indeno(1,2,3-c,d)pyrene phenanthrene anthracene pyrene chrysene benzo(a)anthracene acenaphthylene
sum of PAH by calculation (calculated)
Regulated area: Tests
SOP č.78-1 (ČSN EN 17503)
77 Drinking, ground and surface water Determination of selected analytes by liquid chromatography (LC/MS/MS) (negative/positive mode) and calculation of the sum of pesticides
Regulated area: Tests
SOP č.79-1 (EPA Method 535; EPA Method 536; aplikační listy firmy Agilent Technologies)
78 Drinking, ground and surface water Determination of glyphosate and its metabolites after derivatisation by liquid chromatography (LC/MS/MS)
glyphosate AMPA glufosinate-ammonium
Regulated area: Tests
SOP č.80-1 (ČSN ISO 21458; EPA Method 535; EPA Method 536)
79 Drinking, ground, surface and waste water, leachates of solid materials and waste Determination of hydrocarbons C10 to C40 by gas chromatography (GC/FID)
Regulated area: Tests
SOP č.81-1 (ČSN EN ISO 9377-2)
80 Solid matrices Determination of hydrocarbons C10 to C40 by gas chromatography (GC/FID)
Regulated area: Tests
SOP č.82-1 (ČSN EN 14039)
81 Drinking and surface water Determination of microcystin-LR by liquid chromatography (LC/MS/MS)
Regulated area: Tests
SOP č.83-1 (ČSN ISO 20179, Příloha A)
82 Drinking, ground, surface and waste water, bathing water, leachates of solid materials and waste Determination of organic carbon (TOC, DOC) with NDIR analyser
Regulated area: Tests
SOP č.84-1 (ČSN EN 1484)
83 Drinking, ground, surface and waste water Coulometric determination of adsorbable organically bound halogens (AOX)
Regulated area: Tests
SOP č.85-1 (ČSN EN ISO 9562)
84 Solid matrices Determination of adsorbable organically bound halogens (AOX)
Regulated area: Tests
SOP č.86-1 (DIN 38 414 - 18; ČSN EN 16166)
85 Drinking, ground and surface water Determination of haloacetic acids by liquid chromatography (LC/MS/MS) and calculation of their sum
bromoacetic acid (MBAA) dibromoacetic acid (DBAA) chloroacetic acid (MCAA) dichloroacetic acid (DCAA) trichloroacetic acid (TCAA)
sum of haloacetic acids by calculation (calculated)
Regulated area: Tests
SOP č.87-1 (EPA Method 557)
86 Drinking, ground, surface and waste water, leachates of solid materials and waste Determination of elements by ICP-MS, calculation of the sum of calcium and magnesium
Barium (Ba) Beryllium (Be) Boron (B) Calcium (Ca) Magnesium (Mg) Potassium (K) Sodium (Na) Iron (Fe) Manganese (Mn) Aluminium (Al) Vanadium (V) Cobalt (Co) Copper (Cu) Lead (Pb) Zinc (Zn) Cadmium (Cd) Chromium (Cr) Nickel (Ni) Arsenic (As) Selenium (Se) Molybdenum (Mo) Silver (Ag) Antimony (Sb) Thallium (Tl) Tin (Sn) Phosphorus (P) Uranium (U)
Regulated area: Tests
SOP č.88-1 (ČSN EN ISO 17294-2)
87 Solid matrices Determination of elements by ICP-MS
Barium (Ba) Beryllium (Be) Boron (B) Calcium (Ca) Magnesium (Mg) Potassium (K) Sodium (Na) Iron (Fe) Manganese (Mn) Aluminium (Al) Vanadium (V) Cobalt (Co) Copper (Cu) Lead (Pb) Zinc (Zn) Cadmium (Cd) Chromium (Cr) Nickel (Ni) Arsenic (As) Selenium (Se) Molybdenum (Mo) Silver (Ag) Antimony (Sb) Thallium (Tl) Tin (Sn) Phosphorus (P) Uranium (U)
Regulated area: Tests
SOP č.89-1 (ČSN EN ISO 17294-2; ČSN EN 16171)
88 Drinking, ground, surface and waste water, leachates of solid materials and waste, solid matrices Determination of total mercury with AMA 254 analyser
Regulated area: Tests
SOP č.90-1 (ČSN 75 7440)
89 Drinking, ground and surface water Spectrophotometric determination of hexavalent chromium
Regulated area: Tests
SOP č.91-1 (ČSN ISO 11083)
90 Drinking, ground, surface and waste water Determination of gross beta activity with a proportional counter
Regulated area: Tests
SOP č.92-1 (ČSN 75 7612)
91 Drinking, ground, surface and waste water Determination of gross alpha activity with a proportional counter
Regulated area: Tests
SOP č.93-1 (ČSN 75 7611)
92 Drinking, ground, surface and waste water Determination of gross alpha activity by scintillation
Regulated area: Tests
SOP č.94-1 (ČSN 75 7611)
93 Drinking, ground, surface and waste water Determination of radium-226 by precipitation method with a scintillation detector
Regulated area: Tests
SOP č.95-1 (ČSN 75 7611)
94 Drinking, ground and surface water Determination of radon-222 activity concentration by gamma measurement
Regulated area: Tests
SOP č.96-1 (ČSN 75 7624)
95 Drinking, hot and bottled water Manual sampling of drinking water
Regulated area: Sampling
SP č.1 (ČSN EN ISO 5667-3; ČSN ISO 5667-5; ČSN EN ISO 5667-14; ČSN EN ISO 5667-16; ČSN EN ISO 19458; Vyhláška č. 252/2004 Sb.)
96 Waste water Manual and automatic sampler sampling of waste water
Regulated area: Sampling
SP č.2 (ČSN EN ISO 5667-3; ČSN ISO 5667-10; ČSN EN ISO 5667-14; ČSN 75 7315)
97 Ground water Static sampling of ground water
Regulated area: Sampling
SP č.3 (ČSN EN ISO 5667-3; ČSN ISO 5667-11; ČSN EN ISO 5667-14; ČSN EN ISO 5667-16; ČSN EN ISO 19458)
98 Surface water Manual sampling of surface water
Regulated area: Sampling
SP č.4 (ČSN EN ISO 5667-3; ČSN ISO 5667-4; ČSN EN ISO 5667-6; ČSN EN ISO 5667-14; ČSN EN ISO 5667-16; ČSN EN ISO 19458)
99 Bathing water Manual sampling of bathing water
Regulated area: Sampling
SP č.9 (Vyhláška č. 238/2011 Sb.; ČSN EN ISO 19458)
100 Sewage and waterworks sludges, sands, screenings, suspended sediments, river sediments Manual sampling of solid matrices
Regulated area: Sampling
SP č.8 (ČSN ISO 5667-12; ČSN EN ISO 5667-13; ČSN EN ISO 5667-15)
Workplace Boskovice
101 Drinking, ground, surface and waste water, bathing water Determination of pH by potentiometry
Regulated area: Tests
SOP č.1 (ČSN ISO 10523)
102 Drinking, ground and surface water Determination of electrical conductivity
Regulated area: Tests
SOP č.3 (ČSN EN 27888)
103 Surface and waste water Gravimetric determination of dissolved and total solids, loss on ignition and dissolved inorganic salts (RAS)
Regulated area: Tests
SOP č.6 (ČSN 75 7346; ČSN 75 7347)
104 Surface and waste water Gravimetric determination of suspended solids and loss on ignition
Regulated area: Tests
SOP č.7 (ČSN EN 872; ČSN 75 7350)
105 Solid matrices Gravimetric determination of total solids (dry matter) and water content
Regulated area: Tests
SOP č.8 (ČSN EN 15934)
106 Solid matrices Gravimetric determination of loss on ignition
Regulated area: Tests
SOP č.9 (ČSN EN 15935)
107 Drinking, ground and surface water Titrimetric determination of chemical oxygen demand with permanganate (CODMn)
Regulated area: Tests
SOP č.10 (ČSN EN ISO 8467)
108 Waste water Spectrophotometric determination of chemical oxygen demand with dichromate (CODCr) using HACH test kit
Regulated area: Tests
SOP č.11 (ČSN ISO 15705; návod firmy HACH)
109 Ground, surface and waste water Determination of biochemical oxygen demand after 5 days (BOD5) with LDO probe
Regulated area: Tests
SOP č.12 (ČSN EN ISO 5815-1; ČSN EN 1899-2)
110 Drinking, ground, surface and waste water Spectrophotometric determination of ammonium ions and ammonia nitrogen
Regulated area: Tests
SOP č.13 (ČSN ISO 7150-1)
111 Drinking, ground, surface and waste water Spectrophotometric determination of nitrite and nitrite nitrogen
Regulated area: Tests
SOP č.14 (ČSN EN 26777)
112 Drinking, ground, surface and waste water, bathing water Spectrophotometric determination of nitrate and nitrate nitrogen and calculation of inorganic nitrogen from measured values
Regulated area: Tests
SOP č.15 (ČSN ISO 7890-3)
113 Drinking, ground and surface water Titrimetric determination of chloride
Regulated area: Tests
SOP č.17 (ČSN ISO 9297)
114 Drinking, ground, surface and waste water Spectrophotometric determination of nitrate nitrogen using HACH test kit and calculation of nitrate from measured values
Regulated area: Tests
SOP č.19 (návod firmy HACH)
115 Drinking, ground, surface and waste water Spectrophotometric determination of nitrite nitrogen using HACH test kit and calculation of nitrite from measured values
Regulated area: Tests
SOP č.20 (návod firmy HACH)
116 Drinking, ground and surface water Titrimetric determination of acid neutralising capacity (ANC)
Regulated area: Tests
SOP č.22 (ČSN EN ISO 9963-1)
117 Drinking, ground and surface water Titrimetric determination of base neutralising capacity (BNC)
Regulated area: Tests
SOP č.23 (ČSN 75 7372)
118 Drinking, ground and surface water, bathing water Determination of turbidity by nephelometry
Regulated area: Tests
SOP č.24 (ČSN EN ISO 7027-1)
119 Drinking, ground and surface water, bathing water Spectrophotometric determination of colour by measuring absorbance at 410 nm
Regulated area: Tests
SOP č.25 (ČSN EN ISO 7887; Metoda C)
120 Drinking water, bathing water Spectrophotometric determination of free and total chlorine using HACH test kit and calculation of bound chlorine from measured values
Regulated area: Tests
SOP č.26 (ČSN EN ISO 7393-2; návod firmy HACH)
121 Drinking, ground, surface and waste water, bathing water Measurement of temperature
Regulated area: Tests
SOP č.27 (ČSN 75 7342)
122 Drinking, ground and surface water Preliminary sensory determination of odour and taste
Regulated area: Tests
SOP č.28 (ČSN EN 1622; ČSN 75 7340)
123 Drinking, ground, surface and waste water Determination of dissolved oxygen by luminescence method with LDO probe
Regulated area: Tests
SOP č.29 (ČSN ISO 17289; návod firmy HACH)
124 Drinking, ground and surface water Microscopic determination of abioseston
Regulated area: Tests
SOP č.55 (ČSN 75 7713)
125 Drinking, ground and surface water Microscopic determination of bioseston
Regulated area: Tests
SOP č.56 (ČSN 75 7712)
126 Drinking, ground and surface water, bathing water Enumeration of Escherichia coli and coliform bacteria by membrane filtration
Regulated area: Tests
SOP č.57 (ČSN EN ISO 9308-1)
127 Drinking, ground and surface water, bathing water Enumeration of intestinal enterococci by membrane filtration
Regulated area: Tests
SOP č.59 (ČSN EN ISO 7899-2)
128 Drinking, ground and surface water, bathing water Enumeration of culturable microorganisms by inoculation in a nutrient agar culture medium at 36 °C and 22 °C
Regulated area: Tests
SOP č.60 (ČSN EN ISO 6222)
129 Drinking, ground and surface water, bathing water Enumeration of Escherichia coli and coliform bacteria by most probable number method with a commercial kit
Regulated area: Tests
SOP č.62 (ČSN EN ISO 9308-2; návod výrobce IDEXX, Xebios)
130 Drinking water, bathing water Enumeration of Legionella by membrane filtration
Regulated area: Tests
SOP č.67 (ČSN EN ISO 11731)
131 Drinking, ground and surface water, bathing water Enumeration of Staphylococcus aureus by membrane filtration
Regulated area: Tests
SOP č.68 (ČSN EN ISO 6888-1)
132 Drinking, ground and surface water, bathing water Enumeration of Pseudomonas aeruginosa by membrane filtration
Regulated area: Tests
SOP č.69 (ČSN EN ISO 16266)
133 Drinking, ground and surface water Enumeration of Clostridium perfringens by membrane filtration
Regulated area: Tests
SOP č.70 (ČSN EN ISO 14189)
134 Drinking, ground and surface water Titrimetric determination of the sum of calcium and magnesium and calculation of magnesium
Regulated area: Tests
SOP č.97 (ČSN ISO 6059)
135 Drinking, ground and surface water Spectrophotometric determination of manganese
Regulated area: Tests
SOP č.98 (ČSN ISO 6333; návod firmy MACHERY-NAGEL)
136 Drinking, ground and surface water Spectrophotometric determination of iron
Regulated area: Tests
SOP č.99 (ČSN ISO 6332)
137 Drinking, ground and surface water Spectrophotometric determination of aluminium
Regulated area: Tests
SOP č.100 (ČSN ISO 10566)
138 Drinking, ground and surface water Titrimetric determination of sulphate with lead nitrate
Regulated area: Tests
SOP č.101 (ČSN 75 7477)
139 Drinking, ground, surface and waste water Spectrophotometric determination of phosphate and total phosphorus
Regulated area: Tests
SOP č.102 (ČSN EN ISO 6878; návod firmy MERCK/HACH)
140 Waste water Spectrophotometric determination of total nitrogen using HACH test kit
Regulated area: Tests
SOP č.103 (ČSN EN ISO 11905-1; návod firmy HACH)
141 Drinking, ground and surface water Titrimetric determination of calcium
Regulated area: Tests
SOP č.110 (ČSN ISO 6058)
142 Drinking, hot and bottled water Manual sampling of drinking water
Regulated area: Sampling
SP č.1 (ČSN EN ISO 5667-3; ČSN ISO 5667-5; ČSN EN ISO 5667-14; ČSN EN ISO 5667-16; ČSN EN ISO 19458; Vyhláška č. 252/2004 Sb.)
143 Waste water Manual and automatic sampler sampling of waste water
Regulated area: Sampling
SP č.2 (ČSN EN ISO 5667-3; ČSN ISO 5667-10; ČSN EN ISO 5667-14; ČSN 75 7315)
144 Ground water Static sampling of ground water
Regulated area: Sampling
SP č.3 (ČSN EN ISO 5667-3; ČSN ISO 5667-11; ČSN EN ISO 5667-14; ČSN EN ISO 5667-16; ČSN EN ISO 19458)
145 Surface water Manual sampling of surface water
Regulated area: Sampling
SP č.4 (ČSN EN ISO 5667-3; ČSN ISO 5667-4; ČSN EN ISO 5667-6; ČSN EN ISO 5667-14; ČSN EN ISO 5667-16; ČSN EN ISO 19458)
146 Bathing water Manual sampling of bathing water
Regulated area: Sampling
SP č.9 (Vyhláška č. 238/2011 Sb.; ČSN EN ISO 19458)
147 Sewage and waterworks sludges, sands, screenings, suspended sediments, river sediments Manual sampling of solid matrices
Regulated area: Sampling
SP č.8 (ČSN ISO 5667-12; ČSN EN ISO 5667-13; ČSN EN ISO 5667-15)
Workplace Jihlava
148 Drinking, ground, surface and waste water Determination of pH by potentiometry
Regulated area: Tests
SOP č.1 (ČSN ISO 10523)
149 Drinking, ground and surface water Determination of electrical conductivity
Regulated area: Tests
SOP č.3 (ČSN EN 27888)
150 Drinking, ground and surface water Spectrophotometric determination of absorbance at 254 nm
Regulated area: Tests
SOP č.5 (ČSN 75 7360)
151 Ground, surface and waste water Gravimetric determination of dissolved and total solids, loss on ignition and dissolved inorganic salts (RAS)
Regulated area: Tests
SOP č.6 (ČSN 75 7346; ČSN 75 7347)
152 Ground, surface and waste water Gravimetric determination of suspended solids and loss on ignition
Regulated area: Tests
SOP č.7 (ČSN EN 872; ČSN 75 7350)
153 Drinking, ground and surface water Titrimetric determination of chemical oxygen demand with permanganate (CODMn)
Regulated area: Tests
SOP č.10 (ČSN EN ISO 8467)
154 Drinking, ground, surface and waste water Spectrophotometric determination of chemical oxygen demand with dichromate (CODCr) using MERCK test kit
Regulated area: Tests
SOP č.11 (ČSN ISO 15705; návod firmy MERCK)
155 Ground, surface and waste water Determination of biochemical oxygen demand after 5 days (BOD5) with LDO probe
Regulated area: Tests
SOP č.12 (ČSN EN ISO 5815-1; ČSN EN 1899-2)
156 Drinking, ground and surface water Spectrophotometric determination of ammonium ions and ammonia nitrogen
Regulated area: Tests
SOP č.13 (ČSN ISO 7150-1)
157 Drinking, ground, surface and waste water Spectrophotometric determination of nitrite and nitrite nitrogen
Regulated area: Tests
SOP č.14 (ČSN EN 26777)
158 Drinking, ground, surface and waste water Spectrophotometric determination of nitrate and nitrate nitrogen and calculation of inorganic nitrogen from measured values
Regulated area: Tests
SOP č.15 (ČSN ISO 7890-3)
159 Ground, surface and waste water Spectrophotometric determination of nitrate nitrogen using MERCK test kit and calculation of nitrate from measured values
Regulated area: Tests
SOP č.19 (návod firmy MERCK)
160 Drinking, ground and surface water Titrimetric determination of acid neutralising capacity (ANC)
Regulated area: Tests
SOP č.22 (ČSN EN ISO 9963-1)
161 Drinking, ground and surface water Titrimetric determination of base neutralising capacity (BNC)
Regulated area: Tests
SOP č.23 (ČSN 75 7372)
162 Drinking, ground and surface water Determination of turbidity by nephelometry
Regulated area: Tests
SOP č.24 (ČSN EN ISO 7027-1)
163 Drinking, ground and surface water Spectrophotometric determination of colour by measuring absorbance at 410 nm
Regulated area: Tests
SOP č.25 (ČSN EN ISO 7887; Metoda C)
164 Drinking water Spectrophotometric determination of free and total chlorine using HACH test kit and calculation of bound chlorine from measured values
Regulated area: Tests
SOP č.26 (ČSN EN ISO 7393-2; návod firmy HACH)
165 Drinking, ground, surface and waste water Measurement of temperature
Regulated area: Tests
SOP č.27 (ČSN 75 7342)
166 Drinking, ground and surface water Preliminary sensory determination of odour and taste
Regulated area: Tests
SOP č.28 (ČSN EN 1622; ČSN 75 7340)
167 Drinking, ground, surface and waste water Determination of dissolved oxygen by luminescence method with LDO probe
Regulated area: Tests
SOP č.29 (ČSN ISO 17289; návod firmy HACH)
168 Drinking, ground and surface water Spectrophotometric determination of humic substances
Regulated area: Tests
SOP č.33 (ČSN 75 7536)
169 Ground, surface and waste water Gravimetric determination of extractable substances (EL)
Regulated area: Tests
SOP č.35 (ČSN 75 7508)
170 Drinking, ground, surface and waste water Spectrophotometric determination of anionic surfactants using a test kit
Regulated area: Tests
SOP č.54 (návod firmy HACH a MERCK)
171 Drinking, ground and surface water Microscopic determination of abioseston
Regulated area: Tests
SOP č.55 (ČSN 75 7713)
172 Drinking, ground and surface water Microscopic determination of bioseston
Regulated area: Tests
SOP č.56 (ČSN 75 7712)
173 Drinking, ground and surface water Enumeration of Escherichia coli and coliform bacteria by membrane filtration
Regulated area: Tests
SOP č.57 (ČSN EN ISO 9308-1)
174 Drinking, ground and surface water Enumeration of thermotolerant coliform bacteria and Escherichia coli by membrane filtration
Regulated area: Tests
SOP č.58 (ČSN 75 7835)
175 Drinking, ground and surface water Enumeration of intestinal enterococci by membrane filtration
Regulated area: Tests
SOP č.59 (ČSN EN ISO 7899-2)
176 Drinking, ground and surface water Enumeration of culturable microorganisms by inoculation in a nutrient agar culture medium at 36 °C and 22 °C
Regulated area: Tests
SOP č.60 (ČSN EN ISO 6222)
177 Drinking, ground and surface water Enumeration of Clostridium perfringens by membrane filtration
Regulated area: Tests
SOP č.61 (Vyhláška č.252/2004 Sb.; Vyhláška č.70/2018 Sb.)
178 Drinking, ground and surface water Enumeration of Escherichia coli and coliform bacteria by most probable number method with a commercial kit
Regulated area: Tests
SOP č.62 (ČSN EN ISO 9308-2; návod výrobce IDEXX, Xebios)
179 Drinking, ground and surface water Enumeration of Clostridium perfringens by membrane filtration
Regulated area: Tests
SOP č.70 (ČSN EN ISO 14189)
180 Drinking, ground and surface water Spectrophotometric determination of manganese
Regulated area: Tests
SOP č.98 (ČSN ISO 6333; návod firmy MACHERY-NAGEL)
181 Drinking, ground and surface water Spectrophotometric determination of iron
Regulated area: Tests
SOP č.99 (ČSN ISO 6332)
182 Drinking, ground, surface and waste water Spectrophotometric determination of phosphate and total phosphorus
Regulated area: Tests
SOP č.102 (ČSN EN ISO 6878; návod firmy MERCK)
183 Drinking, ground, surface and waste water Spectrophotometric determination of total nitrogen using MERCK test kit
Regulated area: Tests
SOP č.103 (ČSN EN ISO 11905-1; návod firmy MERCK)
184 Surface and waste water Titrimetric determination of ammonium ions and calculation of ammonia nitrogen and inorganic nitrogen
Regulated area: Tests
SOP č.104 (ČSN ISO 5664)
185 Drinking, ground, surface and waste water Spectrophotometric determination of total phosphorus using MERCK test kit
Regulated area: Tests
SOP č.105 (návod firmy MERCK)
186 Drinking, ground and surface water Determination of nitrate by UV spectrophotometry
Regulated area: Tests
SOP č.106
187 Drinking, hot and bottled water Manual sampling of drinking water
Regulated area: Sampling
SP č.1 (ČSN EN ISO 5667-3; ČSN ISO 5667-5; ČSN EN ISO 5667-14; ČSN EN ISO 5667-16; ČSN EN ISO 19458; Vyhláška č. 252/2004 Sb.)
188 Waste water Manual and automatic sampler sampling of waste water
Regulated area: Sampling
SP č.2 (ČSN EN ISO 5667-3; ČSN ISO 5667-10; ČSN EN ISO 5667-14; ČSN 75 7315)
189 Ground water Static sampling of ground water
Regulated area: Sampling
SP č.3 (ČSN EN ISO 5667-3; ČSN ISO 5667-11; ČSN EN ISO 5667-14; ČSN EN ISO 5667-16; ČSN EN ISO 19458)
190 Surface water Manual sampling of surface water
Regulated area: Sampling
SP č.4 (ČSN EN ISO 5667-3; ČSN ISO 5667-4; ČSN EN ISO 5667-6; ČSN EN ISO 5667-14; ČSN EN ISO 5667-16; ČSN EN ISO 19458)
191 Sewage and waterworks sludges, sands, screenings, suspended sediments, river sediments Manual sampling of solid matrices
Regulated area: Sampling
SP č.8 (ČSN ISO 5667-12; ČSN EN ISO 5667-13; ČSN EN ISO 5667-15)
Workplace Třebíč – drinking water laboratory
192 Drinking, ground and surface water Determination of pH by potentiometry
Regulated area: Tests
SOP č.1 (ČSN ISO 10523)
193 Drinking, ground and surface water Spectrophotometric determination of absorbance at 254 nm
Regulated area: Tests
SOP č.5 (ČSN 75 7360)
194 Drinking, ground and surface water Titrimetric determination of chemical oxygen demand with permanganate (CODMn)
Regulated area: Tests
SOP č.10 (ČSN EN ISO 8467)
195 Drinking, ground and surface water Titrimetric determination of base neutralising capacity (BNC)
Regulated area: Tests
SOP č.23 (ČSN 75 7372)
196 Drinking, ground and surface water Determination of turbidity by nephelometry
Regulated area: Tests
SOP č.24 (ČSN EN ISO 7027-1)
197 Drinking water Spectrophotometric determination of free and total chlorine using HACH test kit and calculation of bound chlorine from measured values
Regulated area: Tests
SOP č.26 (ČSN EN ISO 7393-2; návod firmy HACH)
198 Drinking, ground and surface water Measurement of water temperature
Regulated area: Tests
SOP č.27 (ČSN 75 7342)
199 Drinking, ground and surface water Preliminary sensory determination of odour and taste
Regulated area: Tests
SOP č.28 (ČSN EN 1622; ČSN 75 7340)
200 Drinking, ground and surface water Determination of dissolved oxygen by luminescence method with LDO probe
Regulated area: Tests
SOP č.29 (ČSN ISO 17289; návod firmy HACH)
201 Drinking, ground and surface water Spectrophotometric determination of humic substances
Regulated area: Tests
SOP č.33 (ČSN 75 7536)
202 Drinking, ground and surface water Determination of pH by potentiometry with Gallery automatic analyser
Regulated area: Tests
SOP č.37 (návod firmy Thermo Scientific)
203 Drinking, ground and surface water Determination of electrical conductivity with Gallery automatic analyser
Regulated area: Tests
SOP č.38 (návod firmy Thermo Scientific)
204 Drinking, ground and surface water Spectrophotometric determination of ammonium ions with Gallery automatic analyser
Regulated area: Tests
SOP č.39 (návod firmy Thermo Scientific)
205 Drinking, ground and surface water Spectrophotometric determination of nitrate with Gallery automatic analyser
Regulated area: Tests
SOP č.40 (návod firmy Thermo Scientific)
206 Drinking, ground and surface water Spectrophotometric determination of nitrite with Gallery automatic analyser
Regulated area: Tests
SOP č.41 (návod firmy Thermo Scientific)
207 Drinking, ground and surface water Spectrophotometric determination of phosphate with Gallery automatic analyser
Regulated area: Tests
SOP č.42 (návod firmy Thermo Scientific)
208 Drinking, ground and surface water Spectrophotometric determination of chloride with Gallery automatic analyser
Regulated area: Tests
SOP č.43 (návod firmy Thermo Scientific)
209 Drinking, ground and surface water Spectrophotometric determination of sulphate with Gallery automatic analyser
Regulated area: Tests
SOP č.44 (návod firmy Thermo Scientific)
210 Drinking, ground and surface water Spectrophotometric determination of acid neutralising capacity (ANC) with Gallery automatic analyser
Regulated area: Tests
SOP č.45 (návod firmy Thermo Scientific)
211 Drinking, ground and surface water Spectrophotometric determination of colour with Gallery automatic analyser
Regulated area: Tests
SOP č.46 (návod firmy Thermo Scientific)
212 Drinking, ground and surface water Spectrophotometric determination of calcium with Gallery automatic analyser and calculation of the sum of calcium and magnesium
Regulated area: Tests
SOP č.47 (návod firmy Thermo Scientific)
213 Drinking, ground and surface water Spectrophotometric determination of magnesium with Gallery automatic analyser and calculation of the sum of calcium and magnesium
Regulated area: Tests
SOP č.48 (návod firmy Thermo Scientific)
214 Drinking, ground and surface water Spectrophotometric determination of iron with Gallery automatic analyser
Regulated area: Tests
SOP č.49 (návod firmy Thermo Scientific)
215 Drinking, ground and surface water Spectrophotometric determination of manganese with Gallery automatic analyser
Regulated area: Tests
SOP č.50 (návod firmy Thermo Scientific)
216 Drinking, ground and surface water Spectrophotometric determination of aluminium with Gallery automatic analyser
Regulated area: Tests
SOP č.51 (návod firmy Thermo Scientific)
217 Drinking, ground and surface water Microscopic determination of abioseston
Regulated area: Tests
SOP č.55 (ČSN 75 7713)
218 Drinking, ground and surface water Microscopic determination of bioseston
Regulated area: Tests
SOP č.56 (ČSN 75 7712)
219 Drinking, ground and surface water Enumeration of Escherichia coli and coliform bacteria by membrane filtration
Regulated area: Tests
SOP č.57 (ČSN EN ISO 9308-1)
220 Drinking, ground and surface water Enumeration of thermotolerant coliform bacteria and Escherichia coli by membrane filtration
Regulated area: Tests
SOP č.58 (ČSN 75 7835)
221 Drinking, ground and surface water Enumeration of intestinal enterococci by membrane filtration
Regulated area: Tests
SOP č.59 (ČSN EN ISO 7899-2)
222 Drinking, ground and surface water Enumeration of culturable microorganisms by inoculation in a nutrient agar culture medium at 36 °C and 22 °C
Regulated area: Tests
SOP č.60 (ČSN EN ISO 6222)
223 Drinking, ground and surface water Enumeration of Clostridium perfringens by membrane filtration
Regulated area: Tests
SOP č.61 (Vyhláška č.252/2004 Sb.; Vyhláška č.70/2018 Sb.)
224 Drinking, ground and surface water Enumeration of Escherichia coli and coliform bacteria by most probable number method with a commercial kit
Regulated area: Tests
SOP č.62 (ČSN EN ISO 9308-2; návod výrobce IDEXX, Xebios)
225 Drinking, ground and surface water Enumeration of Clostridium perfringens by membrane filtration
Regulated area: Tests
SOP č.70 (ČSN EN ISO 14189)
226 Drinking, ground and surface water Determination of nitrate by UV spectrophotometry
Regulated area: Tests
SOP č.106
227 Drinking, hot and bottled water Manual sampling of drinking water
Regulated area: Sampling
SP č.1 (ČSN EN ISO 5667-3; ČSN ISO 5667-5; ČSN EN ISO 5667-14; ČSN EN ISO 5667-16; ČSN EN ISO 19458; Vyhláška č. 252/2004 Sb.)
228 Ground water Static sampling of ground water
Regulated area: Sampling
SP č.3 (ČSN EN ISO 5667-3; ČSN ISO 5667-11; ČSN EN ISO 5667-14; ČSN EN ISO 5667-16; ČSN EN ISO 19458)
229 Surface water Manual sampling of surface water
Regulated area: Sampling
SP č.4 (ČSN EN ISO 5667-3; ČSN ISO 5667-4; ČSN EN ISO 5667-6; ČSN EN ISO 5667-14; ČSN EN ISO 5667-16; ČSN EN ISO 19458)
Workplace Třebíč – waste water laboratory
230 Surface and waste water Determination of pH by potentiometry
Regulated area: Tests
SOP č.1 (ČSN ISO 10523)
231 Surface and waste water Gravimetric determination of dissolved and total solids, loss on ignition and dissolved inorganic salts (RAS)
Regulated area: Tests
SOP č.6 (ČSN 75 7346; ČSN 75 7347)
232 Drinking, ground, surface and waste water Gravimetric determination of suspended solids and loss on ignition
Regulated area: Tests
SOP č.7 (ČSN EN 872; ČSN 75 7350)
233 Drinking, ground, surface and waste water Spectrophotometric determination of chemical oxygen demand with dichromate (CODCr) using HACH test kit
Regulated area: Tests
SOP č.11 (ČSN ISO 15705; návod firmy HACH)
234 Drinking, ground, surface and waste water Determination of biochemical oxygen demand after 5 days (BOD5) with LDO probe
Regulated area: Tests
SOP č.12 (ČSN EN ISO 5815-1; ČSN EN 1899-2)
235 Surface and waste water Spectrophotometric determination of nitrate nitrogen using HACH test kit and calculation of nitrate from measured values
Regulated area: Tests
SOP č.19 (návod firmy HACH)
236 Surface and waste water Spectrophotometric determination of nitrite nitrogen using HACH test kit and calculation of nitrite from measured values
Regulated area: Tests
SOP č.20 (návod firmy HACH)
237 Surface and waste water Measurement of temperature
Regulated area: Tests
SOP č.27 (ČSN 75 7342)
238 Drinking, ground, surface and waste water Determination of dissolved oxygen by luminescence method with LDO probe
Regulated area: Tests
SOP č.29 (ČSN ISO 17289; návod firmy HACH)
239 Drinking, ground, surface and waste water Spectrophotometric determination of total nitrogen using HACH test kit
Regulated area: Tests
SOP č.103 (ČSN EN ISO 11905-1; návod firmy HACH)
240 Surface and waste water Titrimetric determination of ammonium ions and calculation of ammonia nitrogen and inorganic nitrogen
Regulated area: Tests
SOP č.104 (ČSN ISO 5664)
241 Surface and waste water Spectrophotometric determination of total phosphorus using HACH test kit
Regulated area: Tests
SOP č.105 (návod firmy HACH)
242 Waste water Manual and automatic sampler sampling of waste water
Regulated area: Sampling
SP č.2 (ČSN EN ISO 5667-3; ČSN ISO 5667-10; ČSN EN ISO 5667-14; ČSN 75 7315)
243 Surface water Manual sampling of surface water
Regulated area: Sampling
SP č.4 (ČSN EN ISO 5667-3; ČSN ISO 5667-4; ČSN EN ISO 5667-6; ČSN EN ISO 5667-14; ČSN EN ISO 5667-16; ČSN EN ISO 19458)
244 Sewage and waterworks sludges, sands, screenings, suspended sediments, river sediments Manual sampling of solid matrices
Regulated area: Sampling
SP č.8 (ČSN ISO 5667-12; ČSN EN ISO 5667-13; ČSN EN ISO 5667-15)
Workplace Znojmo – drinking water laboratory
245 Drinking, ground and surface water, bathing water Determination of pH by potentiometry
Regulated area: Tests
SOP č.1 (ČSN ISO 10523)
246 Drinking, ground and surface water Determination of electrical conductivity
Regulated area: Tests
SOP č.3 (ČSN EN 27888)
247 Drinking, ground and surface water Spectrophotometric determination of absorbance at 254 nm
Regulated area: Tests
SOP č.5 (ČSN 75 7360)
248 Drinking, ground and surface water, bathing water Titrimetric determination of chemical oxygen demand with permanganate (CODMn)
Regulated area: Tests
SOP č.10 (ČSN EN ISO 8467)
249 Drinking, ground and surface water, bathing water Spectrophotometric determination of ammonium ions and ammonia nitrogen
Regulated area: Tests
SOP č.13 (ČSN ISO 7150-1)
250 Drinking, ground and surface water Spectrophotometric determination of nitrite and nitrite nitrogen
Regulated area: Tests
SOP č.14 (ČSN EN 26777)
251 Drinking, ground and surface water Titrimetric determination of acid neutralising capacity (ANC)
Regulated area: Tests
SOP č.22 (ČSN EN ISO 9963-1)
252 Drinking, ground and surface water Titrimetric determination of base neutralising capacity (BNC)
Regulated area: Tests
SOP č.23 (ČSN 75 7372)
253 Drinking, ground and surface water, bathing water Determination of turbidity by nephelometry
Regulated area: Tests
SOP č.24 (ČSN EN ISO 7027-1)
254 Drinking, ground and surface water Spectrophotometric determination of colour by measuring absorbance at 410 nm
Regulated area: Tests
SOP č.25 (ČSN EN ISO 7887; Metoda C)
255 Drinking water, bathing water Spectrophotometric determination of free and total chlorine using HACH test kit and calculation of bound chlorine from measured values
Regulated area: Tests
SOP č.26 (ČSN EN ISO 7393-2; návod firmy HACH)
256 Drinking, ground and surface water, bathing water Measurement of temperature
Regulated area: Tests
SOP č.27 (ČSN 75 7342)
257 Drinking, ground and surface water Preliminary sensory determination of odour and taste
Regulated area: Tests
SOP č.28 (ČSN EN 1622; ČSN 75 7340)
258 Drinking, ground and surface water, bathing water Determination of dissolved oxygen by luminescence method with LDO probe
Regulated area: Tests
SOP č.29 (ČSN ISO 17289; návod firmy HACH)
259 Drinking, ground and surface water Spectrophotometric determination of humic substances
Regulated area: Tests
SOP č.33 (ČSN 75 7536)
260 Drinking, ground and surface water Microscopic determination of abioseston
Regulated area: Tests
SOP č.55 (ČSN 75 7713)
261 Drinking, ground and surface water Microscopic determination of bioseston
Regulated area: Tests
SOP č.56 (ČSN 75 7712)
262 Drinking, ground and surface water, bathing water Enumeration of Escherichia coli and coliform bacteria by membrane filtration
Regulated area: Tests
SOP č.57 (ČSN EN ISO 9308-1)
263 Drinking, ground and surface water Enumeration of thermotolerant coliform bacteria and Escherichia coli by membrane filtration
Regulated area: Tests
SOP č.58 (ČSN 75 7835)
264 Drinking, ground and surface water Enumeration of intestinal enterococci by membrane filtration
Regulated area: Tests
SOP č.59 (ČSN EN ISO 7899-2)
265 Drinking, ground and surface water, bathing water Enumeration of culturable microorganisms by inoculation in a nutrient agar culture medium at 36 °C and 22 °C
Regulated area: Tests
SOP č.60 (ČSN EN ISO 6222)
266 Drinking, ground and surface water, bathing water Enumeration of Escherichia coli and coliform bacteria by most probable number method with a commercial kit
Regulated area: Tests
SOP č.62 (ČSN EN ISO 9308-2; návod výrobce IDEXX, Xebios)
267 Drinking water, bathing water Enumeration of Legionella by membrane filtration
Regulated area: Tests
SOP č.67 (ČSN EN ISO 11731)
268 Drinking, ground and surface water, bathing water Enumeration of Staphylococcus aureus by membrane filtration
Regulated area: Tests
SOP č.68 (ČSN EN ISO 6888-1)
269 Drinking, ground and surface water, bathing water Enumeration of Pseudomonas aeruginosa by membrane filtration
Regulated area: Tests
SOP č.69 (ČSN EN ISO 16266)
270 Drinking, ground and surface water Enumeration of Clostridium perfringens by membrane filtration
Regulated area: Tests
SOP č.70 (ČSN EN ISO 14189)
271 Drinking, ground and surface water Titrimetric determination of the sum of calcium and magnesium and calculation of magnesium
Regulated area: Tests
SOP č.97 (ČSN ISO 6059)
272 Drinking, ground and surface water Spectrophotometric determination of manganese
Regulated area: Tests
SOP č.98 (ČSN ISO 6333; návod firmy MACHERY-NAGEL)
273 Drinking, ground and surface water Spectrophotometric determination of iron
Regulated area: Tests
SOP č.99 (ČSN ISO 6332)
274 Drinking, ground and surface water, bathing water Determination of nitrate by UV spectrophotometry
Regulated area: Tests
SOP č.106
275 Drinking water, bathing water Spectrophotometric determination of ozone with HACH set
Regulated area: Tests
SOP č.108-6 (návod firmy HACH)
276 Drinking, ground and surface water Titrimetric determination of calcium
Regulated area: Tests
SOP č.110 (ČSN ISO 6058)
277 Drinking, hot and bottled water Manual sampling of drinking water
Regulated area: Sampling
SP č.1 (ČSN EN ISO 5667-3; ČSN ISO 5667-5; ČSN EN ISO 5667-14; ČSN EN ISO 5667-16; ČSN EN ISO 19458; Vyhláška č. 252/2004 Sb.)
278 Ground water Static sampling of ground water
Regulated area: Sampling
SP č.3 (ČSN EN ISO 5667-3; ČSN ISO 5667-11; ČSN EN ISO 5667-14; ČSN EN ISO 5667-16; ČSN EN ISO 19458)
279 Surface water Manual sampling of surface water
Regulated area: Sampling
SP č.4 (ČSN EN ISO 5667-3; ČSN ISO 5667-4; ČSN EN ISO 5667-6; ČSN EN ISO 5667-14; ČSN EN ISO 5667-16; ČSN EN ISO 19458)
280 Bathing water Manual sampling of bathing water
Regulated area: Sampling
SP č.9 (Vyhláška č. 238/2011 Sb.; ČSN EN ISO 19458)
Workplace Znojmo – waste water laboratory
281 Drinking, ground, surface and waste water Determination of pH by potentiometry
Regulated area: Tests
SOP č.1 (ČSN ISO 10523)
282 Drinking, ground, surface and waste water Gravimetric determination of dissolved and total solids, loss on ignition and dissolved inorganic salts (RAS)
Regulated area: Tests
SOP č.6 (ČSN 75 7346; ČSN 75 7347)
283 Surface and waste water Gravimetric determination of suspended solids and loss on ignition
Regulated area: Tests
SOP č.7 (ČSN EN 872; ČSN 75 7350)
284 Drinking, ground, surface and waste water Spectrophotometric determination of chemical oxygen demand with dichromate (CODCr) using HACH test kit
Regulated area: Tests
SOP č.11 (ČSN ISO 15705; návod firmy HACH)
285 Drinking, surface and waste water Determination of biochemical oxygen demand after 5 days (BOD5) with LDO probe
Regulated area: Tests
SOP č.12 (ČSN EN ISO 5815-1; ČSN EN 1899-2)
286 Surface and waste water Spectrophotometric determination of ammonium ions and ammonia nitrogen
Regulated area: Tests
SOP č.13 (ČSN ISO 7150-1)
287 Surface and waste water Spectrophotometric determination of nitrite and nitrite nitrogen
Regulated area: Tests
SOP č.14 (ČSN EN 26777)
288 Surface and waste water Spectrophotometric determination of nitrate nitrogen using HACH test kit and calculation of nitrate from measured values
Regulated area: Tests
SOP č.19 (návod firmy HACH)
289 Surface and waste water Spectrophotometric determination of nitrite nitrogen using HACH test kit and calculation of nitrite from measured values
Regulated area: Tests
SOP č.20 (návod firmy HACH)
290 Drinking, ground, surface and waste water Measurement of temperature
Regulated area: Tests
SOP č.27 (ČSN 75 7342)
291 Drinking, ground, surface and waste water Determination of dissolved oxygen by luminescence method with LDO probe
Regulated area: Tests
SOP č.29 (ČSN ISO 17289; návod firmy HACH)
292 Surface and waste water Spectrophotometric determination of total nitrogen using HACH test kit
Regulated area: Tests
SOP č.103 (ČSN EN ISO 11905-1; návod firmy HACH)
293 Surface and waste water Spectrophotometric determination of total phosphorus using HACH test kit
Regulated area: Tests
SOP č.105 (návod firmy HACH)
294 Waste water Manual and automatic sampler sampling of waste water
Regulated area: Sampling
SP č.2 (ČSN EN ISO 5667-3; ČSN ISO 5667-10; ČSN EN ISO 5667-14; ČSN 75 7315)
295 Sewage and waterworks sludges, sands, screenings, suspended sediments, river sediments Manual sampling of solid matrices
Regulated area: Sampling
SP č.8 (ČSN ISO 5667-12; ČSN EN ISO 5667-13; ČSN EN ISO 5667-15)
Workplace Žďár nad Sázavou
296 Drinking, ground, surface and waste water Determination of pH by potentiometry
Regulated area: Tests
SOP č.1 (ČSN ISO 10523)
297 Drinking, ground and surface water Determination of electrical conductivity
Regulated area: Tests
SOP č.3 (ČSN EN 27888)
298 Drinking, ground and surface water Spectrophotometric determination of absorbance at 254 nm
Regulated area: Tests
SOP č.5 (ČSN 75 7360)
299 Drinking, ground, surface and waste water Gravimetric determination of dissolved and total solids, loss on ignition and dissolved inorganic salts (RAS)
Regulated area: Tests
SOP č.6 (ČSN 75 7346; ČSN 75 7347)
300 Drinking, ground, surface and waste water Gravimetric determination of suspended solids and loss on ignition
Regulated area: Tests
SOP č.7 (ČSN EN 872; ČSN 75 7350)
301 Solid matrices Gravimetric determination of total solids (dry matter) and water content
Regulated area: Tests
SOP č.8 (ČSN EN 15934)
302 Solid matrices Gravimetric determination of loss on ignition
Regulated area: Tests
SOP č.9 (ČSN EN 15935)
303 Drinking, ground and surface water Titrimetric determination of chemical oxygen demand with permanganate (CODMn)
Regulated area: Tests
SOP č.10 (ČSN EN ISO 8467)
304 Drinking, ground, surface and waste water Spectrophotometric determination of chemical oxygen demand with dichromate (CODCr) using HACH test kit
Regulated area: Tests
SOP č.11 (ČSN ISO 15705; návod firmy HACH)
305 Surface and waste water Determination of biochemical oxygen demand after 5 days (BOD5) with LDO probe
Regulated area: Tests
SOP č.12 (ČSN EN ISO 5815-1; ČSN EN 1899-2)
306 Drinking, ground and surface water Spectrophotometric determination of ammonium ions and ammonia nitrogen
Regulated area: Tests
SOP č.13 (ČSN ISO 7150-1)
307 Drinking, ground, surface and waste water Spectrophotometric determination of nitrite and nitrite nitrogen
Regulated area: Tests
SOP č.14 (ČSN EN 26777)
308 Drinking, ground, surface and waste water Spectrophotometric determination of nitrate and nitrate nitrogen and calculation of inorganic nitrogen from measured values
Regulated area: Tests
SOP č.15 (ČSN ISO 7890-3)
309 Drinking, ground and surface water Titrimetric determination of chloride
Regulated area: Tests
SOP č.17 (ČSN ISO 9297)
310 Drinking, ground and surface water Titrimetric determination of acid neutralising capacity (ANC)
Regulated area: Tests
SOP č.22 (ČSN EN ISO 9963-1)
311 Drinking, ground, surface and waste water Titrimetric determination of base neutralising capacity (BNC)
Regulated area: Tests
SOP č.23 (ČSN 75 7372)
312 Drinking, ground and surface water Determination of turbidity by nephelometry
Regulated area: Tests
SOP č.24 (ČSN EN ISO 7027-1)
313 Drinking, ground and surface water Spectrophotometric determination of colour by measuring absorbance at 410 nm
Regulated area: Tests
SOP č.25 (ČSN EN ISO 7887; Metoda C)
314 Drinking water Spectrophotometric determination of free and total chlorine using HACH test kit and calculation of bound chlorine from measured values
Regulated area: Tests
SOP č.26 (ČSN EN ISO 7393-2; návod firmy HACH)
315 Drinking, ground, surface and waste water Measurement of temperature
Regulated area: Tests
SOP č.27 (ČSN 75 7342)
316 Drinking, ground and surface water Preliminary sensory determination of odour and taste
Regulated area: Tests
SOP č.28 (ČSN EN 1622; ČSN 75 7340)
317 Drinking, ground, surface and waste water Determination of dissolved oxygen by luminescence method with LDO probe
Regulated area: Tests
SOP č.29 (ČSN ISO 17289; návod firmy HACH)
318 Drinking, ground and surface water Microscopic determination of abioseston
Regulated area: Tests
SOP č.55 (ČSN 75 7713)
319 Drinking, ground and surface water Microscopic determination of bioseston
Regulated area: Tests
SOP č.56 (ČSN 75 7712)
320 Drinking, ground and surface water Enumeration of Escherichia coli and coliform bacteria by membrane filtration
Regulated area: Tests
SOP č.57 (ČSN EN ISO 9308-1)
321 Drinking, ground and surface water Enumeration of thermotolerant coliform bacteria and Escherichia coli by membrane filtration
Regulated area: Tests
SOP č.58 (ČSN 75 7835)
322 Drinking, ground and surface water Enumeration of intestinal enterococci by membrane filtration
Regulated area: Tests
SOP č.59 (ČSN EN ISO 7899-2)
323 Drinking, ground and surface water Enumeration of culturable microorganisms by inoculation in a nutrient agar culture medium at 36 °C and 22 °C
Regulated area: Tests
SOP č.60 (ČSN EN ISO 6222)
324 Drinking, ground and surface water Enumeration of Clostridium perfringens by membrane filtration
Regulated area: Tests
SOP č.61 (Vyhláška č.252/2004 Sb.; Vyhláška č.70/2018 Sb.)
325 Drinking, ground and surface water Enumeration of Escherichia coli and coliform bacteria by most probable number method with a commercial kit
Regulated area: Tests
SOP č.62 (ČSN EN ISO 9308-2; návod výrobce IDEXX, Xebios)
326 Solid matrices Enumeration of thermotolerant coliform bacteria by culture
Regulated area: Tests
SOP č.64 (ČSN 75 7835; AHEM č. 7/2001; AHEM č. 1/2008)
327 Solid matrices Enumeration of intestinal enterococci by culture
Regulated area: Tests
SOP č.65 (ČSN EN ISO 7899-2; AHEM č. 7/2001; AHEM č. 1/2008)
328 Drinking, ground and surface water Enumeration of Clostridium perfringens by membrane filtration
Regulated area: Tests
SOP č.70 (ČSN EN ISO 14189)
329 Drinking, ground and surface water Titrimetric determination of the sum of calcium and magnesium and calculation of magnesium
Regulated area: Tests
SOP č.97 (ČSN ISO 6059)
330 Drinking, ground and surface water Spectrophotometric determination of manganese
Regulated area: Tests
SOP č.98 (ČSN ISO 6333; návod firmy MACHERY-NAGEL)
331 Drinking, ground and surface water Spectrophotometric determination of iron
Regulated area: Tests
SOP č.99 (ČSN ISO 6332)
332 Drinking, ground and surface water Spectrophotometric determination of aluminium
Regulated area: Tests
SOP č.100 (ČSN ISO 10566)
333 Drinking, ground and surface water Titrimetric determination of sulphate with lead nitrate
Regulated area: Tests
SOP č.101 (ČSN 75 7477)
334 Drinking, ground and surface water Spectrophotometric determination of phosphate and total phosphorus
Regulated area: Tests
SOP č.102 (ČSN EN ISO 6878)
335 Drinking, ground, surface and waste water Spectrophotometric determination of total nitrogen using HACH test kit
Regulated area: Tests
SOP č.103 (ČSN EN ISO 11905-1; návod firmy HACH)
336 Surface and waste water Titrimetric determination of ammonium ions and calculation of ammonia nitrogen and inorganic nitrogen
Regulated area: Tests
SOP č.104 (ČSN ISO 5664)
337 Drinking, ground and surface water Determination of nitrate by UV spectrophotometry
Regulated area: Tests
SOP č.106
338 Drinking, ground and surface water Titrimetric determination of calcium
Regulated area: Tests
SOP č.110 (ČSN ISO 6058)
339 Surface and waste water Spectrophotometric determination of total phosphorus using HACH test kit
Regulated area: Tests
SOP č.105 (návod firmy HACH)
340 Drinking, hot and bottled water Manual sampling of drinking water
Regulated area: Sampling
SP č.1 (ČSN EN ISO 5667-3; ČSN ISO 5667-5; ČSN EN ISO 5667-14; ČSN EN ISO 5667-16; ČSN EN ISO 19458; Vyhláška č. 252/2004 Sb.)
341 Waste water Manual and automatic sampler sampling of waste water
Regulated area: Sampling
SP č.2 (ČSN EN ISO 5667-3; ČSN ISO 5667-10; ČSN EN ISO 5667-14; ČSN 75 7315)
342 Ground water Static sampling of ground water
Regulated area: Sampling
SP č.3 (ČSN EN ISO 5667-3; ČSN ISO 5667-11; ČSN EN ISO 5667-14; ČSN EN ISO 5667-16; ČSN EN ISO 19458)
343 Surface water Manual sampling of surface water
Regulated area: Sampling
SP č.4 (ČSN EN ISO 5667-3; ČSN ISO 5667-4; ČSN EN ISO 5667-6; ČSN EN ISO 5667-14; ČSN EN ISO 5667-16; ČSN EN ISO 19458)
344 Sewage and waterworks sludges, sands, screenings, suspended sediments, river sediments Manual sampling of solid matrices
Regulated area: Sampling
SP č.8 (ČSN ISO 5667-12; ČSN EN ISO 5667-13; ČSN EN ISO 5667-15)

Reference standards (232)

AHEM č. 1/2008
AHEM č. 7/2001
DIN 38 414 - 18
DIN 38414-20
EPA Method 535
EPA Method 536
EPA Method 557
Metoda C
SOP č.1
SOP č.10
SOP č.100
SOP č.101
SOP č.102
SOP č.103
SOP č.104
SOP č.105
SOP č.106
SOP č.108-6
SOP č.11
SOP č.110
SOP č.12
SOP č.13
SOP č.14
SOP č.15
SOP č.16-1
SOP č.17
SOP č.18-1
SOP č.19
SOP č.2-1
SOP č.20
SOP č.21-1
SOP č.22
SOP č.23
SOP č.24
SOP č.25
SOP č.26
SOP č.27
SOP č.28
SOP č.29
SOP č.3
SOP č.30-1
SOP č.31-1
SOP č.32-1
SOP č.33
SOP č.34-1
SOP č.35
SOP č.36-1
SOP č.37
SOP č.38
SOP č.39
SOP č.4-1
SOP č.40
SOP č.41
SOP č.42
SOP č.43
SOP č.44
SOP č.45
SOP č.46
SOP č.47
SOP č.48
SOP č.49
SOP č.5
SOP č.50
SOP č.51
SOP č.52-1
SOP č.53-1
SOP č.54
SOP č.55
SOP č.56
SOP č.57
SOP č.58
SOP č.59
SOP č.6
SOP č.60
SOP č.61
SOP č.62
SOP č.63-1
SOP č.64
SOP č.65
SOP č.66-1
SOP č.67
SOP č.68
SOP č.69
SOP č.7
SOP č.70
SOP č.71-1
SOP č.72-1
SOP č.73-1
SOP č.75-1
SOP č.76-1
SOP č.77-1
SOP č.78-1
SOP č.79-1
SOP č.8
SOP č.80-1
SOP č.81-1
SOP č.82-1
SOP č.83-1
SOP č.84-1
SOP č.85-1
SOP č.86-1
SOP č.87-1
SOP č.88-1
SOP č.89-1
SOP č.9
SOP č.90-1
SOP č.91-1
SOP č.92-1
SOP č.93-1
SOP č.94-1
SOP č.95-1
SOP č.96-1
SOP č.97
SOP č.98
SOP č.99
SP č.1
SP č.2
SP č.3
SP č.4
SP č.8
SP č.9
Vyhláška č. 238/2011 Sb.
Vyhláška č. 252/2004 Sb.
Vyhláška č.252/2004 Sb.
Vyhláška č.70/2018 Sb.
aplikační listy firmy Agilent Technologies
návod firmy HACH
návod firmy HACH a MERCK
návod firmy HACH, MERCK
návod firmy MACHERY-NAGEL
návod firmy MERCK
návod firmy MERCK/HACH
návod firmy Thermo Scientific
návod výrobce IDEXX, Xebios
ČSN 75 7315
ČSN 75 7340
ČSN 75 7342
ČSN 75 7346
ČSN 75 7347
ČSN 75 7350
ČSN 75 7360
ČSN 75 7372
ČSN 75 7415
ČSN 75 7440
ČSN 75 7477
ČSN 75 7508
ČSN 75 7536
ČSN 75 7611
ČSN 75 7612
ČSN 75 7624
ČSN 75 7712
ČSN 75 7713
ČSN 75 7835
ČSN EN 12457-4
ČSN EN 13342
ČSN EN 14039
ČSN EN 1484
ČSN EN 15934
ČSN EN 15935
ČSN EN 16166
ČSN EN 16171
ČSN EN 1622
ČSN EN 17322
ČSN EN 17503
ČSN EN 1899-2
ČSN EN 26777
ČSN EN 27888
ČSN EN 872
ČSN EN 903
ČSN EN ISO 10301
ČSN EN ISO 10304-1
ČSN EN ISO 10304-4
ČSN EN ISO 10390
ČSN EN ISO 11348-2
ČSN EN ISO 11348-3
ČSN EN ISO 11731
ČSN EN ISO 11905-1
ČSN EN ISO 14189
ČSN EN ISO 15009
ČSN EN ISO 15061
ČSN EN ISO 15680
ČSN EN ISO 16266
ČSN EN ISO 17294-2
ČSN EN ISO 17993
ČSN EN ISO 19458
ČSN EN ISO 20236
ČSN EN ISO 5667-13
ČSN EN ISO 5667-14
ČSN EN ISO 5667-15
ČSN EN ISO 5667-16
ČSN EN ISO 5667-3
ČSN EN ISO 5667-6
ČSN EN ISO 5815-1
ČSN EN ISO 6222
ČSN EN ISO 6468
ČSN EN ISO 6579-1
ČSN EN ISO 6878
ČSN EN ISO 6888-1
ČSN EN ISO 7027-1
ČSN EN ISO 7393-2
ČSN EN ISO 7887
ČSN EN ISO 7899-2
ČSN EN ISO 8467
ČSN EN ISO 9308-1
ČSN EN ISO 9308-2
ČSN EN ISO 9377-2
ČSN EN ISO 9562
ČSN EN ISO 9963-1
ČSN ISO 10359-1
ČSN ISO 10523
ČSN ISO 10530
ČSN ISO 10566
ČSN ISO 11083
ČSN ISO 15705
ČSN ISO 17289
ČSN ISO 19250
ČSN ISO 20179, Příloha A
ČSN ISO 21458
ČSN ISO 5664
ČSN ISO 5667-10
ČSN ISO 5667-11
ČSN ISO 5667-12
ČSN ISO 5667-4
ČSN ISO 5667-5
ČSN ISO 6058
ČSN ISO 6059
ČSN ISO 6332
ČSN ISO 6333
ČSN ISO 6439
ČSN ISO 7150-1
ČSN ISO 7890-3
ČSN ISO 9297

The same scope as data (JSON): https://labcoda.pl/api/accreditation-scopes/labs/CZ/1249