🇨🇿 Pražské vodovody a kanalizace, a.s. PL

ČIA 1247 • Praha 10, Czech Republic • 201 methods

Water & wastewaterEnvironmentMicrobiology

Pražské vodovody a kanalizace, a.s. is a laboratory accredited by ČIA under number 1247 (Praha 10, Czech Republic). Its accreditation scope covers 201 test methods in the following areas: Water & wastewater, Environment, Microbiology. Test objects include: Drinking, surface, raw, intermediate-stage and bottled water, Drinking, ground, surface, raw, bottled water, water from intermedi…, Drinking, raw and intermediate-stage water, Wastewater.

At a glance

  • Accreditation number: ČIA 1247
  • Methods in scope: 201
  • Types of test objects: 67
  • City: Praha 10, Czech Republic
  • Valid until: 11-03-2027
Accreditation number
1247
Accreditation body
ČIA
Address
Dykova 3, 101 00 Praha 10
City
Praha 10, Czech Republic
Division
Pražské vodovody a kanalizace, a.s. – dział kontroli jakości wody
Valid until
11-03-2027

What this laboratory tests (67)

Laboratory sections (6)

Laboratory locations

Certificate information

Certificate date
20.07.2026

Accreditation scope — test methods (201)

No. Test object Methodology / Parameters Technique Reference document
Laboratory Control Department Prague
1 Drinking, hot, surface, raw, intermediate-stage and bottled water, process chemicals Determination of pH by potentiometry
Regulated area: Tests
SOP č. DV-1 (ČSN ISO 10523)
2 Drinking, surface, raw, intermediate-stage and bottled water Determination of electrical conductivity by conductometry
Regulated area: Tests
SOP č. DV-9 (ČSN EN 27888)
3 Drinking, surface, raw, intermediate-stage and bottled water Determination of acid neutralizing capacity (KNK4,5 and KNK8,3) by acid-base titration
Regulated area: Tests
SOP č. DV-2 (ČSN EN ISO 9963-1)
4 Drinking, surface, raw, intermediate-stage and bottled water Determination of base neutralizing capacity (ZNK8,3) by acid-base titration and calculation of the forms of carbon dioxide
Regulated area: Tests
SOP č. DV-18 (ČSN 75 7372; ČSN 75 7373)
5 Drinking, hot, surface, raw, intermediate-stage and bottled water and bathing water Determination of chemical oxygen demand by permanganate (CODMn) by manganometric titration
Regulated area: Tests
SOP č. DV-3 (ČSN EN ISO 8467 a modifikovaná Schulz-Pappova metoda dle JAM, 1965, 114)
6 Drinking, surface, raw, intermediate-stage and bottled water and bathing water Determination of ammonium ions by spectrophotometry using a Merck kit, calculation of free ammonia and ammonium nitrogen
Regulated area: Tests
SOP č. DV-4 (návod firmy Merck; ČSN ISO 7150-1)
7 Drinking, surface, raw, intermediate-stage and bottled water Determination of nitrites by spectrophotometry using a Merck kit and calculation of nitrite nitrogen
Regulated area: Tests
SOP č. DV-5 (návod firmy Merck; ČSN EN 26777)
8 Drinking, surface, raw, intermediate-stage and bottled water and bathing water Determination of nitrates by spectrophotometry with sulfosalicylic acid and calculation of nitrate nitrogen, total inorganic nitrogen and total nitrogen
Regulated area: Tests
SOP č. DV-6 (ČSN ISO 7890-3)
9 Drinking, intermediate-stage and bottled water Determination of nitrates by UV spectrophotometry
Regulated area: Tests
SOP č. DV-24 (Janoušek I., Fiala J.: Vodní hospodářství, 2, 1988, 51)
10 Drinking, surface, raw, intermediate-stage and bottled water Determination of chlorides by argentometric titration
Regulated area: Tests
SOP č. DV-7 (ČSN ISO 9297)
11 Drinking, surface, raw, intermediate-stage and bottled water Determination of calcium by complexometric titration
Regulated area: Tests
SOP č. DV-12 (ČSN ISO 6058)
12 Drinking, surface, raw, intermediate-stage and bottled water Determination of the sum of calcium and magnesium (Ca + Mg) by complexometric titration and calculation of magnesium
Regulated area: Tests
SOP č. DV-8 (ČSN ISO 6059)
13 Drinking, hot, surface, raw, intermediate-stage and bottled water and bathing water Determination of turbidity by nephelometry
Regulated area: Tests
SOP č. DV-10 (ČSN EN ISO 7027-1)
14 Drinking, hot, surface, raw, intermediate-stage and bottled water Determination of colour by photometry
Regulated area: Tests
SOP č. DV-11 (ČSN EN ISO 7887, metoda C)
15 Drinking, surface, raw, intermediate-stage and bottled water and bathing water Determination of absorbance at 254 nm by spectrophotometry
Regulated area: Tests
SOP č. SAK-6 (ČSN 75 7360)
16 Drinking, surface, raw, intermediate-stage and bottled water Determination of absorbance at 278 nm by spectrophotometry
Regulated area: Tests
SOP č. SAK-28 (ČSN 75 7360)
17 Drinking, intermediate-stage and bottled water Determination of iron by spectrophotometry using a Merck kit
Regulated area: Tests
SOP č. DV-14 (návod firmy Merck)
18 Drinking, hot, surface, raw, intermediate-stage and bottled water Determination of iron by spectrophotometry with 1,10-phenanthroline
Regulated area: Tests
SOP č. DV-15 (ČSN ISO 6332)
19 Drinking, surface, raw, intermediate-stage and bottled water Determination of sulphates by nephelometry with barium chloride
Regulated area: Tests
SOP č. DV-16 (Bouda, Michenková, Sponar: sborník Hydrochímia, 1983, 3)
20 Drinking, hot, surface, raw, intermediate-stage and bottled water Determination of orthophosphates and total phosphorus by spectrophotometry using a Merck kit
Regulated area: Tests
SOP č. DV-17 (návod firmy Merck; ČSN EN ISO 6878)
21 Drinking, surface, raw, intermediate-stage and bottled water and bathing water Determination of dissolved anions by liquid ion chromatography – bromates, nitrates, nitrites, fluorides, orthophosphates, chlorates, chlorides, chlorites and sulphates
Regulated area: Tests
SOP č. SAK-30 - část A (ČSN EN ISO 10304-1; ČSN EN ISO 10304-4; ČSN EN ISO 15061; EPA Method 300.1)
22 Aqueous solution of disinfectants: hypochlorite, Savo Determination of dissolved anions by liquid ion chromatography – bromates, chlorates, chlorites and chlorides
Regulated area: Tests
SOP č. SAK-30 - část B (ČSN EN ISO 10304-4; ČSN EN ISO 15061; EPA Method 300.1; ČSN EN 901)
23 Drinking, surface, raw, intermediate-stage and bottled water Determination of aluminium by spectrophotometry
Regulated area: Tests
SOP č. DV-25 (ČSN ISO 10 566)
24 Drinking, surface, raw, intermediate-stage and bottled water Determination of chemical oxygen demand by dichromate (CODCr) by spectrophotometry using a Merck kit
Regulated area: Tests
SOP č. SAK-1 (návod firmy Merck; ČSN ISO 15705)
25 Drinking, intermediate-stage and bottled water Determination of total cyanides by spectrophotometry using a Hach cuvette test
Regulated area: Tests
SOP č. SAK-3 (návod firmy Hach)
26 Drinking, surface, raw, intermediate-stage and bottled water Determination of total cyanides by distillation method, spectrophotometrically after distillation
Regulated area: Tests
SOP č. SAK-92 (ČSN 75 7415)
27 Drinking, surface, raw, intermediate-stage and bottled water Determination of dissolved solids dried at 105 °C and ignited at 550 °C by gravimetry
Regulated area: Tests
SOP č. SAK-7 (ČSN 75 7346)
28 Surface, raw and intermediate-stage water Determination of suspended solids dried at 105 °C by gravimetry
Regulated area: Tests
SOP č. SAK-72 (ČSN EN 872)
29 Drinking, surface, raw, intermediate-stage and bottled water Determination of humic substances by spectrophotometry after extraction
Regulated area: Tests
SOP č. SAK-71 (ČSN 75 7536)
30 Drinking, surface, raw, intermediate-stage and bottled water Determination of anionic surfactants (MBAS) by spectrophotometry after extraction
Regulated area: Tests
SOP č. SAK-73 (ČSN EN 903)
31 Drinking, hot, surface, raw, intermediate-stage and bottled water Sensory determination of odour – odour grade and threshold odour number (TON)
Regulated area: Tests
SOP č. DV-21 (ČSN 75 7340; ČSN EN 1622)
32 Drinking and bottled water Sensory determination of taste – taste grade and threshold flavour number (TFN)
Regulated area: Tests
SOP č. DV-27 (ČSN 75 7340; ČSN EN 1622)
33 Drinking, surface, raw and intermediate-stage water Determination of dissolved oxygen and biochemical oxygen demand after 5 days (BSK5, BOD5) by electrochemical method
Regulated area: Tests
SOP č. SAK-79 (ČSN EN ISO 5814; ČSN EN ISO 5815-1; ČSN EN 1899-2)
34 Aqueous solution of disinfectants: hypochlorite, Savo Determination of free and total chlorine by spectrophotometry using a Hach kit
Regulated area: Tests
SOP č. DV-13 (návod firmy Hach; ČSN EN ISO 7393-2)
35 Process chemicals, drinking and bottled water Determination of hydrogen peroxide by manganometric titration
Regulated area: Tests
SOP č. DV-94 (ČSN EN 902; návod firmy Merck)
36 Drinking and bottled water Determination of hydrogen peroxide by spectrophotometry using a Merck kit
Regulated area: Tests
SOP č. DV-95 (návod firmy Merck)
37 Drinking, ground, surface, raw, intermediate-stage, process and bottled water Determination of dissolved forms of silicon by spectrophotometry using a Merck kit and calculation of silicates as SiO2
Regulated area: Tests
SOP č. DV-30 (návod firmy Merck; DIN 38405-21)
38 Drinking, surface, raw, intermediate-stage and bottled water Determination of mercury by atomic absorption (AMA)
Regulated area: Tests
SOP č. SAK-16 (ČSN 75 7440)
39 Drinking, surface, raw, intermediate-stage and bottled water Determination of the elements silver, aluminium, arsenic, boron, barium, beryllium, calcium, cadmium, cobalt, chromium, copper, iron, potassium, lithium, magnesium, manganese, sodium, nickel, phosphorus, lead, antimony, selenium, uranium, vanadium and zinc by ICP-MS and calculation of the sum of calcium and magnesium (Ca + Mg)
Regulated area: Tests
SOP č. SAK-95 (ČSN EN ISO 17294-1; ČSN EN ISO 17294-2)
40 Drinking, hot, surface, raw, intermediate-stage and bottled water and bathing water Determination of total organic carbon (TOC) and dissolved organic carbon (DOC) by persulphate oxidation with UV irradiation and by thermal oxidation with infrared spectrometric detection
Regulated area: Tests
SOP č. SAK-5 (ČSN EN 1484)
41 Drinking, surface, raw, intermediate-stage and bottled water, extracts of aqueous samples Determination of polycyclic aromatic hydrocarbons (PAH) by HPLC with fluorescence detector and calculation of the sum of PAH
benzo(a)pyrene fluoranthene benzo(b)fluoranthene benzo(k)fluoranthene indeno(1,2,3cd)pyrene benzo(g,h,i)perylene
Regulated area: Tests
SOP č. SAK-23 (ČSN EN ISO 17993)
42 Drinking, surface, raw, intermediate-stage and bottled water Determination of organochlorine pesticides (OCP) and polychlorinated biphenyls (PCB) by GC/ECD and calculation of the sum of OCP and PCB
aldrin dieldrin heptachlor heptachlor epoxide lindane hexachlorobenzene p,p´-DDT p,p´-DDE methoxychlor PCB: PCB congeners No. 28, 52, 101, 118, 138, 153, 180
Regulated area: Tests
SOP č. SAK-24 (EPA 505)
43 Drinking, hot, surface, raw, intermediate-stage and bottled water Determination of volatile organic compounds (VOC) by Purge & Trap and GC/MS and calculation of the sum of trihalomethanes (THM)
1,1-dichloroethene 1,2-dichloroethane cis-1,2-dichloroethene trans-1,2-dichloroethene 1,1,2-trichloroethene 1,1,2,2-tetrachloroethene 1,2-dichlorobenzene 1,3-dichlorobenzene 1,4-dichlorobenzene benzene bromodichloromethane bromoform chlorobenzene chloroform dibromochloromethane dichloromethane ethylbenzene m+p-xylene o-xylene styrene tetrachloromethane toluene vinyl chloride
calculation of 1,2-dichloroethene, bromoforms, dichlorobenzenes, xylenes, trihalomethanes (calculated)
Regulated area: Tests
SOP č. SAK-21 (EPA 524.2)
44 Drinking, surface, raw, intermediate-stage and bottled water Determination of N-(phosphonomethyl)glycine (glyphosate) and aminomethylphosphonic acid (AMPA) by HPLC with fluorescence detector
Regulated area: Tests
SOP č. SAK-22 (ČSN ISO 21458; Analytical and Bioanalytical Chemistry 2008, 391: 2265-2276)
45 Soil, construction material, waste from wastewater treatment technology Determination of polycyclic aromatic hydrocarbons (PAH) by HPLC with fluorescence and UV detector using QuEChERS and calculation of the sum of PAH
benzo(a)pyrene fluoranthene benzo(b)fluoranthene benzo(k)fluoranthene indeno(1,2,3cd)pyrene benzo(g,h,i)perylene anthracene benzo(a)anthracene phenanthrene chrysene naphthalene pyrene acenaphthylene acenaphthene fluorene dibenzo(a,h)anthracene
Regulated area: Tests
SOP č. SAK-20 (ČSN EN 17503; aplikační list QuEChERS firmy Agilent Technologies)
46 Drinking, surface, raw, intermediate-stage and bottled water Determination of selected analytes by LC/MS and calculation of the sum of pesticide substances (PL)
Regulated area: Tests
SOP č. SAK-100 (EPA 536; ČSN ISO 21676; aplikační listy firmy Agilent Technologies)
47 Coagulant ferric sulphate Determination of ferrous iron by oxidimetric titration with potassium dichromate, ferric iron by iodometric titration with sodium thiosulphate and calculation of total iron and ferric sulphate content
Regulated area: Tests
SOP č. DV–101 - část A (ČSN EN 17215)
48 Coagulant ferric sulphate Determination of insoluble matter by gravimetry
Regulated area: Tests
SOP č. DV–101 - část B (ČSN EN 17215)
49 Coagulant ferric sulphate Determination of free sulphuric acid by acid-base titration
Regulated area: Tests
SOP č. DV–101 - část C (ČSN EN 17215)
50 Coagulant ferric sulphate Determination of density by hydrometer
Regulated area: Tests
SOP č. DV–101 - část D (ČSN 65 0342)
51 Process chemicals Determination of aluminium by complexometric titration and calculation of aluminium oxide and aluminium sulphate content
Regulated area: Tests
SOP č. DV–102 - část A (ČSN EN 1302)
52 Process chemicals Determination of total and ferrous iron by oxidimetric titration with potassium dichromate and calculation of ferric iron
Regulated area: Tests
SOP č. DV–102 - část B (ČSN EN 1302:2000)
53 Process chemicals Determination of insoluble matter by gravimetry
Regulated area: Tests
SOP č. DV–102 - část C (ČSN EN 1302)
54 Process chemicals Determination of free sulphuric acid by acid-base titration
Regulated area: Tests
SOP č. DV–102 - část D (ČSN EN 1302)
55 Process chemicals Determination of density by hydrometer
Regulated area: Tests
SOP č. DV–102 - část E (ČSN 65 0342)
56 Hydrated lime Determination of water-soluble calcium hydroxide Ca(OH)2 in dry matter by acidimetric titration
Regulated area: Tests
SOP č. DV–103 - část A (ČSN EN 12485)
57 Hydrated lime Determination of water-insoluble matter by gravimetry
Regulated area: Tests
SOP č. DV–103 - část B (ČSN EN 12485)
58 Hydrated lime Determination of free water (moisture) by gravimetry
Regulated area: Tests
SOP č. DV–103 - část C (ČSN EN 12485)
59 Hydrated lime Determination of carbon dioxide (CO2) content by gravimetry and calculation of calcium carbonate CaCO3 in dry matter
Regulated area: Tests
SOP č. DV–103 - část D (ČSN EN 12485)
60 Drinking, surface, raw, intermediate-stage and bottled water Determination of coliform bacteria by membrane filtration
Regulated area: Tests
SOP č. MB I/4 (ČSN 75 7837)
61 Drinking, hot, intermediate-stage and bottled water and bathing water Determination of coliform bacteria and Escherichia coli by membrane filtration
Regulated area: Tests
SOP č. MB I/16 (ČSN EN ISO 9308-1)
62 Drinking and hot water Determination of coliform bacteria and Escherichia coli by the most probable number method
Regulated area: Tests
SOP č. MB I/21 (ČSN EN ISO 9308-2)
63 Drinking, surface, raw, intermediate-stage and bottled water Determination of thermotolerant coliform bacteria and Escherichia coli by membrane filtration
Regulated area: Tests
SOP č. MB I/6 (ČSN 75 7835)
64 Drinking, surface, raw, intermediate-stage and bottled water Determination of intestinal enterococci by membrane filtration
Regulated area: Tests
SOP č. MB I/8 (ČSN EN ISO 7899-2)
65 Drinking, hot, surface, raw, intermediate-stage and bottled water and bathing water Enumeration of culturable micro-organisms (colony count) at 22 °C and 36 °C by inoculation in a nutrient agar culture medium
Regulated area: Tests
SOP č. MB I/10 (ČSN EN ISO 6222)
66 Surface, raw and intermediate-stage water Determination of mesophilic bacteria by inoculation in a nutrient agar culture medium
Regulated area: Tests
SOP č. MB I/22 (ČSN 75 7841)
67 Surface, raw and intermediate-stage water Determination of psychrophilic bacteria by inoculation in a nutrient agar culture medium
Regulated area: Tests
SOP č. MB I/23 (ČSN 75 7842)
68 Drinking, hot, surface, raw, intermediate-stage and bottled water and bathing water Determination of Pseudomonas aeruginosa by membrane filtration
Regulated area: Tests
SOP č. MB I/13 (ČSN EN ISO 16266)
69 Drinking, surface, raw, intermediate-stage and bottled water Determination of sulphite-reducing anaerobes (clostridia) by membrane filtration
Regulated area: Tests
SOP č. MB I/14 (ČSN EN 26461-2)
70 Drinking, surface, raw, intermediate-stage and bottled water Determination of Clostridium perfringens (including spores) by membrane filtration
Regulated area: Tests
SOP č. MB I/15 (Vyhláška č. 252/2004 Sb., příloha č. 6 ve znění Vyhlášky 70/2018 Sb.)
71 Drinking, surface, raw, intermediate-stage and bottled water Detection of Salmonella by enrichment in liquid medium with subsequent selection and confirmation
Regulated area: Tests
SOP č. MB I/17 (ČSN ISO 19250)
72 Drinking, hot, surface, raw, intermediate-stage and bottled water and bathing water Determination of Staphylococcus aureus by membrane filtration
Regulated area: Tests
SOP č. MB I/19 (ČSN EN ISO 6888-1)
73 Drinking, hot, raw, intermediate-stage and bottled water and bathing water Determination of Legionella and Legionella pneumophila by membrane filtration
Regulated area: Tests
SOP č. MB I/20 (ČSN EN ISO 11731)
74 Drinking, surface, raw, intermediate-stage and bottled water Microscopic determination of bioseston (living organisms, dead organisms, number of organisms) and abioseston
Regulated area: Tests
SOP č. MB I/12 (ČSN 75 7712; ČSN 75 7713)
75 Drinking, surface, raw, intermediate-stage and bottled water Determination of Clostridium perfringens (including spores) by membrane filtration
Regulated area: Tests
SOP č. MB I/11 (ČSN EN ISO 14189)
76 Drinking, surface, raw, intermediate-stage and bottled water Enumeration of somatic coliphages by direct plating on agar culture medium with optional concentration by membrane filtration
Regulated area: Tests
SOP č. MB I/24 (ČSN EN ISO 10705-2; ČSN EN ISO 10705-3)
Drinking Water Sampling Department
77 Drinking, hot, surface, raw, intermediate-stage and bottled water and bathing water, ambient air Determination of temperature
Regulated area: Tests
SOP č. DV-22 (ČSN 75 7342)
78 Drinking, hot and intermediate-stage water and bathing water Determination of free and total chlorine by spectrophotometry using a Hach kit and calculation of combined chlorine
Regulated area: Tests
SOP č. DV-23 (návod firmy Hach; ČSN EN ISO 7393-2)
79 Drinking, surface and raw water and bathing water Field determination of dissolved oxygen and oxygen saturation by luminescence method
Regulated area: Tests
SOP č. DV-62 (návod firmy Hach; ČSN ISO 17289)
80 Drinking, surface, raw, intermediate-stage and bottled water and bathing water Field determination of pH by potentiometry
Regulated area: Tests
SOP č. DV-29 (ČSN ISO 10523)
81 Drinking, surface, raw, intermediate-stage and bottled water and bathing water Determination of oxidation-reduction potential by potentiometry
Regulated area: Tests
SOP č. DV-90 (ČSN 75 7367)
82 Drinking, intermediate-stage and bottled water and bathing water Determination of ozone by spectrophotometry using an AccuVac Hach kit
Regulated area: Tests
SOP č. DV-91 (návod firmy Hach)
83 Drinking and hot water Determination of chlorine dioxide by spectrophotometry using a Hach kit
Regulated area: Tests
SOP č. DV-31 (návod firmy Hach)
84 Drinking, hot and bottled water Sampling of drinking, hot and bottled water – manual sampling
Regulated area: Sampling
SOP č. VZ-1, vyjma kap. 6.1, 6.2, 6.3, 6.6 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-5; ČSN ISO 5667-21; ČSN EN ISO 5667-14; ČSN EN ISO 19458)
85 Surface and raw water Sampling of surface and raw water – manual sampling
Regulated area: Sampling
SOP č. VZ-1, vyjma kap. 6.3 až 6.6 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-4 kap. 12; ČSN EN ISO 5667-6; ČSN EN ISO 5667-14; ČSN EN ISO 19458)
86 Groundwater Sampling of groundwater – manual sampling
Regulated area: Sampling
SOP č. VZ-1, vyjma kap. 6.1, 6.2, 6.4 až 6.6 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-11; ČSN EN ISO 5667-14; ČSN EN ISO 19458)
87 Water from intermediate treatment stages (intermediate-stage water) Sampling of water from intermediate treatment stages – manual sampling
Regulated area: Sampling
SOP č. VZ-1, vyjma kap. 6.1, 6.2, 6.5, 6.6 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-5; ČSN EN ISO 5667-14; ČSN EN ISO 19458)
88 Bathing water (pool water) Sampling of bathing water – manual sampling
Regulated area: Sampling
SOP č. VZ-1, vyjma kap. 6.1 až 6.5 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN EN ISO 5667-14; ČSN EN ISO 19458; Vyhláška č. 238/2011 Sb.)
Laboratory Control Department Káraný, Sojovice water treatment plant
89 Drinking, ground, surface, raw, bottled water, water from intermediate treatment stages Determination of acid neutralizing capacity (KNK4,5) by acid-base titration
Regulated area: Tests
SOP č. CHA-1 (ČSN EN ISO 9963-1)
90 Drinking, ground, surface, raw, bottled water, water from intermediate treatment stages Determination of base neutralizing capacity (ZNK8,3) by acid-base titration and calculation of the forms of carbon dioxide
Regulated area: Tests
SOP č. CHA-5 (ČSN 75 7372; ČSN 75 7373)
91 Drinking, ground, surface, raw, bottled water, water from intermediate treatment stages Determination of the sum of calcium and magnesium (Ca+Mg) by complexometric titration
Regulated area: Tests
SOP č. CHA-2 (ČSN ISO 6059)
92 Drinking, ground, surface, raw, bottled water, water from intermediate treatment stages Determination of calcium by complexometric titration and calculation of magnesium
Regulated area: Tests
SOP č. CHA-3 (ČSN ISO 6058)
93 Drinking, ground, surface, raw, bottled water, water from intermediate treatment stages Determination of chlorides by argentometric titration
Regulated area: Tests
SOP č. CHA-4 (ČSN ISO 9297)
94 Drinking, ground, surface, raw, bottled water, water from intermediate treatment stages Determination of sulphates by nephelometry with barium chloride
Regulated area: Tests
SOP č. CHA-6 (Bouda, Michenková, Sponar: sborník Hydrochímia, 1983, 3)
95 Surface, raw water, water from intermediate treatment stages Determination of suspended solids dried at 105 °C by gravimetry
Regulated area: Tests
SOP č. CHA-7 (ČSN EN 872)
96 Drinking, ground, surface, raw, bottled water, water from intermediate treatment stages Determination of pH by potentiometry
Regulated area: Tests
SOP č. CHA-8 (ČSN ISO 10523)
97 Drinking, ground, surface, raw, bottled water, water from intermediate treatment stages Determination of electrical conductivity by conductometry
Regulated area: Tests
SOP č. CHA-9 (ČSN EN 27888)
98 Drinking, ground, surface, raw, bottled water, water from intermediate treatment stages Determination of ammonium ions by spectrophotometry using a Merck kit
Regulated area: Tests
SOP č. CHA-68 (návod firmy Merck; ČSN ISO 7150-1)
99 Drinking, ground, surface, raw, bottled water, water from intermediate treatment stages Determination of nitrites by spectrophotometry using a Merck kit
Regulated area: Tests
SOP č. CHA-69 (návod firmy Merck; ČSN EN 26777)
100 Drinking, ground, surface, raw, bottled water, water from intermediate treatment stages Determination of nitrates by spectrophotometry with sulfosalicylic acid
Regulated area: Tests
SOP č. CHA-12 (ČSN ISO 7890-3)
101 Drinking, ground, bottled water, water from intermediate treatment stages Determination of nitrates by UV spectrophotometry
Regulated area: Tests
SOP č. CHA-13 (Janoušek I., Fiala J.: Vodní hospodářství, 2, 1988, 51)
102 Drinking, ground, surface, raw, bottled water, water from intermediate treatment stages Determination of colour by photometry
Regulated area: Tests
SOP č. CHA-14 (ČSN EN ISO 7887, metoda C)
103 Drinking, ground, surface, raw, bottled water, water from intermediate treatment stages Determination of turbidity by nephelometry
Regulated area: Tests
SOP č. CHA-15 (ČSN EN ISO 7027-1)
104 Drinking, ground, surface, raw, bottled water, water from intermediate treatment stages Determination of chemical oxygen demand by permanganate (CODMn) by manganometric titration
Regulated area: Tests
SOP č. CHA-16 (ČSN EN ISO 8467)
105 Drinking, ground, surface, raw, bottled water, water from intermediate treatment stages Determination of iron by spectrophotometry with 1,10-phenanthroline
Regulated area: Tests
SOP č. CHA-18 (ČSN ISO 6332)
106 Drinking, ground, surface, raw, bottled water, water from intermediate treatment stages Determination of manganese by spectrophotometry using a Merck kit
Regulated area: Tests
SOP č. CHA-19 (návod firmy Merck)
107 Drinking, ground, surface, raw, bottled water, water from intermediate treatment stages Determination of copper by spectrophotometry using a Merck kit
Regulated area: Tests
SOP č. CHA-20 (návod firmy Merck)
108 Drinking, ground, surface, raw, bottled water, water from intermediate treatment stages Determination of orthophosphates by spectrophotometry using a Merck kit
Regulated area: Tests
SOP č. CHA-70 (návod firmy Merck; ČSN EN ISO 6878)
109 Drinking, ground, surface, raw, bottled water, water from intermediate treatment stages Determination of absorbance at 254 nm by spectrophotometry
Regulated area: Tests
SOP č. CHA-23 (ČSN 75 7360)
110 Drinking and bottled water Determination of hydrogen peroxide by spectrophotometry using a Merck kit
Regulated area: Tests
SOP č. CHA-26 (návod firmy Merck)
111 Drinking, ground, surface, raw, bottled water, water from intermediate treatment stages, ambient air Determination of temperature
Regulated area: Tests
SOP č. CHA-24 (ČSN 75 7342)
112 Drinking, ground water, water from intermediate treatment stages Determination of free chlorine by spectrophotometry using a Hach kit
Regulated area: Tests
SOP č. CHA-51 (návod firmy Hach; ČSN EN ISO 7393-2)
113 Surface, raw water and water from intermediate treatment stages Field determination of dissolved oxygen and oxygen saturation by luminescence method
Regulated area: Tests
SOP č. CHA-21 (návod firmy Hach, ČSN ISO 17289)
114 Drinking water (water treatment plant outlet) Preliminary sensory analysis – determination of odour and taste at the sampling site
Regulated area: Tests
SOP č. CHA-71 (ČSN 75 7340)
115 Drinking, ground, surface, raw, bottled water, water from intermediate treatment stages Determination of coliform bacteria by membrane filtration
Regulated area: Tests
SOP č. MB-I-4 (ČSN 75 7837)
116 Drinking and bottled water and water from intermediate treatment stages Determination of coliform bacteria and Escherichia coli by membrane filtration
Regulated area: Tests
SOP č. MB-I-13 (ČSN EN ISO 9308-1)
117 Drinking water and water from intermediate treatment stages Determination of coliform bacteria and Escherichia coli by the most probable number method
Regulated area: Tests
SOP č. MB-I-14 (ČSN EN ISO 9308-2)
118 Drinking, ground, surface, raw, bottled water, water from intermediate treatment stages Determination of thermotolerant coliform bacteria and Escherichia coli by membrane filtration
Regulated area: Tests
SOP č. MB-I-6 (ČSN 75 7835)
119 Drinking, ground, surface, raw, bottled water, water from intermediate treatment stages Determination of intestinal enterococci by membrane filtration
Regulated area: Tests
SOP č. MB-I-8 (ČSN EN ISO 7899-2)
120 Drinking, ground, surface, raw, bottled water, water from intermediate treatment stages Enumeration of culturable micro-organisms (colony count) at 22 °C and 36 °C by inoculation in a nutrient agar culture medium
Regulated area: Tests
SOP č. MB-I-9 (ČSN EN ISO 6222)
121 Drinking, ground, bottled water and water from intermediate treatment stages Determination of Pseudomonas aeruginosa by membrane filtration
Regulated area: Tests
SOP č. MB-I-11 (ČSN EN ISO 16266)
122 Drinking, ground, bottled water and water from intermediate treatment stages with the character of drinking water Microscopic determination of bioseston (living organisms, number of organisms) and abioseston
Regulated area: Tests
SOP č. MB-I-12 (ČSN 75 7712; ČSN 75 7713)
123 Drinking and bottled water Sampling of drinking and bottled water – manual sampling
Regulated area: Sampling
SOP č. OV-1, vyjma kap. 6.2 až 6.4 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-5; ČSN EN ISO 5667-14; ČSN EN ISO 19458)
124 Surface and raw water Sampling of surface and raw water – manual sampling
Regulated area: Sampling
SOP č. OV-1, vyjma kap. 6.1, 6.3, 6.4 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-4 kap. 12; ČSN EN ISO 5667-6; ČSN EN ISO 5667-14; ČSN EN ISO 19458)
125 Groundwater Sampling of groundwater – manual sampling
Regulated area: Sampling
SOP č. OV-1, vyjma kap. 6.1, 6.2, 6.4 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-11; ČSN EN ISO 5667-14; ČSN EN ISO 19458)
126 Water from intermediate treatment stages (intermediate-stage water) Sampling of water from intermediate treatment stages – manual sampling
Regulated area: Sampling
SOP č. OV-1, vyjma kap. 6.1 až 6.3 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-5; ČSN EN ISO 5667-14; ČSN EN ISO 19458)
Wastewater Sampling Department
127 Wastewater, liquid sludge, ambient air Determination of temperature
Regulated area: Tests
SOP A.7 (ČSN 75 7342)
128 Wastewater Composite and grab sampling of wastewater – manual sampling and sampling by automatic sampler
Regulated area: Sampling
SOP O-1, vyjma kap. 8.2 a 8.3 (ČSN ISO 5667-10; ČSN EN ISO 5667-14; ČSN EN ISO 5667-3; ČSN EN ISO 5667-1; ČSN 75 7315)
129 Liquid sludge Composite and grab sampling of liquid sludge – manual sampling and sampling by automatic sampler
Regulated area: Sampling
SOP O-1, vyjma kap. 8.1 a 8.3 (ČSN EN ISO 5667-13; ČSN EN ISO 5667-14; ČSN EN ISO 5667-15; ČSN EN ISO 5667-3; ČSN EN ISO 5667-1)
130 Surface water Composite and grab sampling of surface water – manual sampling
Regulated area: Sampling
SOP O-1, vyjma kap. 8.1 a 8.2 (ČSN EN ISO 5667-6; ČSN EN ISO 5667-14; ČSN EN ISO 5667-3; ČSN EN ISO 5667-1)
131 Liquid waste Composite and grab sampling of liquid waste – manual sampling and sampling by automatic sampler
Regulated area: Sampling
SOP O-1, vyjma kap. 8.1 až 8.3 (ČSN ISO 5667-10; ČSN EN ISO 5667-13; ČSN EN ISO 5667-14; ČSN EN ISO 5667-15; ČSN EN ISO 5667-3; ČSN EN ISO 5667-1)
132 Soil, construction material, waste from wastewater treatment technology including solid and liquid sludge from wastewater and water treatment plants Composite and grab sampling of waste – manual sampling
Regulated area: Sampling
SOP OD-1 (ČSN EN 14899, TNI CEN/TR 15310-1; TNI CEN/TR 15310-2; TNI CEN/TR 15310-3; TNI CEN/TR 15310-4; TNI CEN/TR 15310-5; ČSN EN ISO 5667-13; ČSN EN ISO 5667-14; ČSN EN ISO 5667-15; ČSN 01 5111; Metodický pokyn MŽP č. 6 ke vzorkování odpadů, Věstník MŽP, částka 4, duben 2008, 1)
133 Solid and liquid sludge from wastewater and water treatment plants Composite and grab sampling of solid and liquid sludge from wastewater and water treatment plants – manual sampling
Regulated area: Sampling
SOP OD-2 (ČSN EN 14899; TNI CEN/TR 15310-1; TNI CEN/TR 15310-2; TNI CEN/TR 15310-3; TNI CEN/TR 15310-4; TNI CEN/TR 15310-5; ČSN EN ISO 5667-13; ČSN EN ISO 5667-14; ČSN EN ISO 5667-15; ČSN 01 5111; Metodický pokyn MŽP č. 6 ke vzorkování odpadů, Věstník MŽP, částka 4, duben 2008, 1)
Wastewater Laboratory Control Department
134 Surface water and wastewater, liquid sludge, liquid waste Determination of chemical oxygen demand by dichromate (CODCr) by titration after oxidation
Regulated area: Tests
SOP A.1 (ČSN ISO 6060)
135 Surface water and wastewater Determination of biochemical oxygen demand (BSK5, BOD5) with an optical probe
Regulated area: Tests
SOP A.2 (ČSN EN ISO 5815-1; ČSN ISO 17289)
136 Surface water and wastewater, liquid sludge, liquid waste Determination of dissolved solids dried at 105 °C (RL) and ignited at 550 °C (dissolved inorganic salts, RAS) by gravimetry and calculation of loss on ignition
Regulated area: Tests
SOP A.3 (ČSN 75 7346; ČSN 75 7347)
137 Surface water and wastewater, liquid sludge, liquid waste Determination of suspended solids dried at 105 °C (NL) and ignited at 550 °C (residue on ignition, NL ash) by gravimetry and calculation of loss on ignition and total solids (VL)
Regulated area: Tests
SOP A.4 (ČSN EN 872; ČSN 75 7350)
138 Wastewater Determination of orthophosphates by spectrophotometry
Regulated area: Tests
SOP A.5 (ČSN EN ISO 6878)
139 Wastewater, liquid sludge, liquid waste Determination of ammonium ions by titration after distillation
Regulated area: Tests
SOP A.9 (ČSN ISO 5664)
140 Surface water and wastewater, liquid sludge, liquid waste Determination of ammonium nitrogen (N-NH4), nitrite nitrogen (N-NO2), nitrate nitrogen (N-NO3), orthophosphate phosphorus (P-PO4) and total phosphorus (P) by flow analysis and calculation of nitrogen forms
Regulated area: Tests
SOP A.12 (ČSN EN ISO 11732; ČSN EN ISO 13395; ČSN EN ISO 15681-2)
141 Surface water and wastewater, liquid sludge, liquid waste Determination of Kjeldahl nitrogen by titration after distillation
Regulated area: Tests
SOP A.15 – část A (ČSN EN 25663; ČSN EN 13342)
142 Solid sludge Determination of Kjeldahl nitrogen by titration after distillation
Regulated area: Tests
SOP A.15 – část B (ČSN EN 25663; ČSN EN 13342)
143 Surface water and wastewater, liquid sludge, liquid waste Determination of pH by potentiometry
Regulated area: Tests
SOP A.16 (ČSN ISO 10523; ČSN EN ISO 10390)
144 Surface water and wastewater Determination of electrical conductivity by conductometry
Regulated area: Tests
SOP A.17 (ČSN EN 27888)
145 Wastewater Determination of acid neutralizing capacity (KNK4,5 and KNK8,3) by acid-base titration
Regulated area: Tests
SOP A.18 (ČSN EN ISO 9963-1)
146 Wastewater Determination of chlorides by argentometric titration
Regulated area: Tests
SOP A.19 (ČSN ISO 9297)
147 Wastewater Determination of anionic surfactants by spectrophotometry using a Merck cuvette test
Regulated area: Tests
SOP A.39 (návod firmy Merck; ČSN EN 903)
148 Wastewater Determination of non-ionic surfactants by spectrophotometry using a Hach cuvette test
Regulated area: Tests
SOP A.33 (návod firmy Hach)
149 Wastewater Determination of sulphates by titration with lead nitrate
Regulated area: Tests
SOP A.35 (ČSN 75 7477)
150 Liquid and solid sludge, liquid waste, solid waste: soil, construction material, waste from wastewater treatment technology Determination of total dry matter and loss on ignition (combustible matter) by gravimetry and calculation of residue on ignition, moisture and C:N ratio – manual method
Regulated area: Tests
SOP A.8 – část A (ČSN EN 12880; ČSN EN 15934; ČSN EN 15935; ČSN 46 5735)
151 Liquid and solid sludge, liquid waste, solid waste: soil, construction material, waste from wastewater treatment technology Determination of total dry matter and loss on ignition (combustible matter) by gravimetry and calculation of residue on ignition, moisture and C:N ratio – method using a PrepASH analyser
Regulated area: Tests
SOP A.8 – část B (ČSN EN 12880; ČSN EN 15934; ČSN EN 15935; ČSN 46 5735)
152 Wastewater, liquid waste Determination of fats and oils by gravimetry after extraction
Regulated area: Tests
SOP A.27 (ČSN 75 7509)
153 Surface water and wastewater, liquid sludge, liquid waste Determination of CODCr by the sealed-tube spectrophotometric method using a Hach cuvette test – method with a Skalar robotic analyser
Regulated area: Tests
SOP A.38 – část A (návod firmy Hach; ČSN ISO 15705)
154 Surface water and wastewater, liquid sludge, liquid waste Determination of CODCr by the sealed-tube spectrophotometric method using a Hach cuvette test – manual method
Regulated area: Tests
SOP A.38 – část B (návod firmy Hach; ČSN ISO 15705)
155 Surface water and wastewater Determination of total nitrogen (TN), total organic carbon (TOC) and dissolved organic carbon (DOC) by thermal oxidation with chemiluminescence detector and infrared spectrometric detection
Regulated area: Tests
SOP A.31 (ČSN EN ISO 20236)
156 Drinking, surface water and wastewater Determination of extractable substances (ELIR) by infrared spectrometry
Regulated area: Tests
SOP A.11 (ČSN 75 7506)
157 Drinking, surface water and wastewater Determination of non-polar extractable substances (NELIR) by infrared spectrometry
Regulated area: Tests
SOP A.23 (ČSN 75 7505)
158 Drinking, surface water and wastewater, liquid sludge, liquid waste Determination of hydrocarbons C10 to C40 by GC/FID after solvent extraction
Regulated area: Tests
SOP A.32 (ČSN EN ISO 9377-2)
159 Solid sludge Determination of hydrocarbons C10 to C40 by GC/FID after solvent extraction
Regulated area: Tests
SOP A.36 (ČSN EN ISO 9377-2; ČSN EN 14039)
160 Drinking, surface water and wastewater, liquid sludge, liquid waste Determination of adsorbable organically bound halogens (AOX) by microcoulometric titration
Regulated area: Tests
SOP A.24 (ČSN EN ISO 9562)
161 Solid sludge, liquid waste Determination of adsorbable organically bound halogens (AOX) by microcoulometric titration
Regulated area: Tests
SOP A.37 (ČSN EN 16166)
162 Wastewater, liquid waste Determination of the elements aluminium, arsenic, calcium, cadmium, chromium, copper, potassium, iron, magnesium, manganese, sodium, nickel, phosphorus, lead, zinc by ICP-OES and calculation of the sum of calcium and magnesium (Ca+Mg)
Regulated area: Tests
SOP A.25 – část A (ČSN EN ISO 11885)
163 Liquid and solid sludge, liquid waste Determination of the elements aluminium, arsenic, beryllium, calcium, cadmium, cobalt, chromium, copper, iron, potassium, magnesium, manganese, molybdenum, nickel, phosphorus, lead, vanadium, zinc by ICP-OES
Regulated area: Tests
SOP A.25 – část B (ČSN EN ISO 11885; ČSN EN ISO 22036)
164 Process chemicals Determination of the elements aluminium, arsenic, cadmium, chromium, iron, manganese, nickel, lead, antimony, selenium by ICP-OES and calculation of aluminium oxide, ferric oxide and manganese dioxide content
Regulated area: Tests
SOP A.25 – část C (ČSN EN ISO 11885; ČSN EN 17215; ČSN EN 1302; ČSN EN 12485)
165 Wastewater, liquid and solid sludge, liquid waste, process chemicals Determination of mercury by single-purpose AAS by atomic absorption (AMA)
Regulated area: Tests
SOP A.28 (ČSN 75 7440)
166 Liquid sludge, activated sludge Microscopic determination of biocoenoses and assessment of floc structure
Regulated area: Tests
SOP A.30 (Technické doporučení II-E-22, Hydroprojekt, 2003; Wanner J. a kol.: Biologická kontrola čistíren odpadních vod, SOVAK ČR, 2019)
167 Wastewater Determination of absorbance and transmittance at 254 nm by spectrophotometry
Regulated area: Tests
SOP A.40 (ČSN 75 7360)
168 Wastewater Determination of turbidity by nephelometry
Regulated area: Tests
SOP A.41 (ČSN EN ISO 7027-1)
Laboratory Control Department Prague – Podolí Laboratory
169 Drinking, raw and intermediate-stage water Determination of pH by potentiometry
Regulated area: Tests
SOP č. LP-1 (ČSN ISO 10523)
170 Drinking, raw and intermediate-stage water Determination of electrical conductivity by conductometry
Regulated area: Tests
SOP č. LP-2 (ČSN EN 27888)
171 Drinking, raw and intermediate-stage water Determination of turbidity by nephelometry
Regulated area: Tests
SOP č. LP-3 (ČSN EN ISO 7027-1)
172 Drinking, raw and intermediate-stage water Determination of acid neutralizing capacity (KNK4,5 and KNK8,3) by acid-base titration
Regulated area: Tests
SOP č. LP-4 (ČSN EN ISO 9963-1)
173 Drinking, raw and intermediate-stage water Determination of base neutralizing capacity (ZNK8,3) by acid-base titration and calculation of the forms of carbon dioxide
Regulated area: Tests
SOP č. LP-5 (ČSN 75 7372; ČSN 75 7373)
174 Drinking, raw and intermediate-stage water Determination of calcium by complexometric titration
Regulated area: Tests
SOP č. LP-6 (ČSN ISO 6058)
175 Drinking, raw and intermediate-stage water Determination of the sum of calcium and magnesium (Ca+Mg) by complexometric titration and calculation of magnesium after titration
Regulated area: Tests
SOP č. LP-7 (ČSN ISO 6059)
176 Drinking, raw and intermediate-stage water Determination of sulphates by nephelometry with barium chloride
Regulated area: Tests
SOP č. LP-8 (Bouda, Michenková, Sponar: sborník Hydrochímia, 1983, 3)
177 Drinking, raw and intermediate-stage water Determination of chemical oxygen demand by permanganate (CODMn) by manganometric titration
Regulated area: Tests
SOP č. LP-9 (ČSN EN ISO 8467)
178 Drinking and intermediate-stage water Determination of iron by spectrophotometry using a Merck kit
Regulated area: Tests
SOP č. LP-10 (návod firmy Merck)
179 Intermediate-stage water Determination of iron by spectrophotometry
Regulated area: Tests
SOP č. LP-11 (ČSN 83 0520-20: 1978, metoda C)
180 Drinking and intermediate-stage water Determination of manganese by spectrophotometry using a Merck kit
Regulated area: Tests
SOP č. LP-12 (návod firmy Merck)
181 Drinking, raw and intermediate-stage water Determination of absorbance at 254 nm by spectrophotometry
Regulated area: Tests
SOP č. LP-13 (ČSN 75 7360)
182 Drinking, raw and intermediate-stage water Determination of colour by photometry
Regulated area: Tests
SOP č. LP-14 (ČSN EN ISO 7887, metoda C)
183 Drinking, raw and intermediate-stage water Determination of ammonium ions by spectrophotometry using a Merck kit and calculation of ammonium nitrogen
Regulated area: Tests
SOP č. LP-15 (návod firmy Merck; ČSN ISO 7150-1)
184 Drinking, raw and intermediate-stage water Determination of nitrites by spectrophotometry using a Merck kit and calculation of nitrite nitrogen
Regulated area: Tests
SOP č. LP-16 (návod firmy Merck; ČSN EN 26777)
185 Drinking, raw and intermediate-stage water Determination of nitrates by spectrophotometry with sulfosalicylic acid and calculation of nitrate nitrogen and total inorganic nitrogen
Regulated area: Tests
SOP č. LP-17 (ČSN ISO 7890-3)
186 Drinking and intermediate-stage water Determination of nitrates by UV spectrophotometry
Regulated area: Tests
SOP č. LP-18 (Janoušek I., Fiala J.: Vodní hospodářství, 2, 1988, 51)
187 Drinking, raw and intermediate-stage water Determination of chlorides by argentometric titration
Regulated area: Tests
SOP č. LP-19 (ČSN ISO 9297)
188 Drinking, raw and intermediate-stage water, ambient air Determination of temperature
Regulated area: Tests
SOP č. LP-20 (ČSN 75 7342)
189 Drinking and intermediate-stage water Determination of free and total chlorine by spectrophotometry using a Hach kit
Regulated area: Tests
SOP č. LP-21 (návod firmy Hach; ČSN EN ISO 7393-2)
190 Raw and intermediate-stage water Determination of dissolved oxygen and oxygen saturation by luminescence method
Regulated area: Tests
SOP č. LP-22 (návod firmy Hach; ČSN ISO 17289)
191 Drinking and raw water Preliminary sensory analysis – determination of odour and taste at the sampling site
Regulated area: Tests
SOP č. LP-23 (ČSN 75 7340)
192 Drinking and intermediate-stage water Determination of hydrogen peroxide by spectrophotometry using a Merck kit
Regulated area: Tests
SOP č. LP-24 (návod firmy Merck)
193 Raw and intermediate-stage water Determination of coliform bacteria by membrane filtration
Regulated area: Tests
SOP č. LPM-1 (ČSN 75 7837)
194 Drinking, raw and intermediate-stage water Determination of thermotolerant coliform bacteria and Escherichia coli by membrane filtration
Regulated area: Tests
SOP č. LPM-2 (ČSN 75 7835)
195 Drinking and intermediate-stage water Determination of coliform bacteria and Escherichia coli by membrane filtration
Regulated area: Tests
SOP č. LPM-3 (ČSN EN ISO 9308-1)
196 Drinking, raw and intermediate-stage water Determination of intestinal enterococci by membrane filtration
Regulated area: Tests
SOP č. LPM-4 (ČSN EN ISO 7899-2)
197 Drinking, raw and intermediate-stage water Enumeration of culturable micro-organisms (colony count) at 22 °C and 36 °C by inoculation in a nutrient agar culture medium
Regulated area: Tests
SOP č. LPM-5 (ČSN EN ISO 6222)
198 Drinking and intermediate-stage water Microscopic determination of bioseston (living organisms, dead organisms, number of organisms) and abioseston
Regulated area: Tests
SOP č. LPM-7 (ČSN 75 7712; ČSN 75 7713)
199 Drinking water Sampling of drinking water – manual sampling
Regulated area: Sampling
SOP č. VP-1, vyjma kap. 5.1, 5.2, 5.3, 5.5, 5.6 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-5; ČSN EN ISO 5667-14; ČSN EN ISO 19458)
200 Raw water Sampling of raw water – manual sampling
Regulated area: Sampling
SOP č. VP-1, vyjma kap. 5.2 až 5.7 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN EN ISO 5667-6; ČSN EN ISO 5667-14; ČSN EN ISO 19458)
201 Water from intermediate treatment stages (intermediate-stage water) Sampling of water from intermediate treatment stages – manual sampling
Regulated area: Sampling
SOP č. VP-1, vyjma kap. 5.1, 5.4 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-5; ČSN EN ISO 5667-6; ČSN EN ISO 5667-14; ČSN EN ISO 19458)

Reference standards (336)

Analytical and Bioanalytical Chemistry 2008, 391: 2265-2276
Bouda, Michenková, Sponar: sborník Hydrochímia, 1983, 3
DIN 38405-21
EPA 505
EPA 524.2
EPA 536
EPA Method 300.1
Janoušek I., Fiala J.: Vodní hospodářství, 2, 1988, 51
Metodický pokyn MŽP č. 6 ke vzorkování odpadů, Věstník MŽP, částka 4, duben 2008, 1
SOP A.1
SOP A.11
SOP A.12
SOP A.15 – část A
SOP A.15 – část B
SOP A.16
SOP A.17
SOP A.18
SOP A.19
SOP A.2
SOP A.23
SOP A.24
SOP A.25 – část A
SOP A.25 – část B
SOP A.25 – část C
SOP A.27
SOP A.28
SOP A.3
SOP A.30
SOP A.31
SOP A.32
SOP A.33
SOP A.35
SOP A.36
SOP A.37
SOP A.38 – část A
SOP A.38 – část B
SOP A.39
SOP A.4
SOP A.40
SOP A.41
SOP A.5
SOP A.7
SOP A.8 – část A
SOP A.8 – část B
SOP A.9
SOP O-1, vyjma kap. 8.1 a 8.2
SOP O-1, vyjma kap. 8.1 a 8.3
SOP O-1, vyjma kap. 8.1 až 8.3
SOP O-1, vyjma kap. 8.2 a 8.3
SOP OD-1
SOP OD-2
SOP č. CHA-1
SOP č. CHA-12
SOP č. CHA-13
SOP č. CHA-14
SOP č. CHA-15
SOP č. CHA-16
SOP č. CHA-18
SOP č. CHA-19
SOP č. CHA-2
SOP č. CHA-20
SOP č. CHA-21
SOP č. CHA-23
SOP č. CHA-24
SOP č. CHA-26
SOP č. CHA-3
SOP č. CHA-4
SOP č. CHA-5
SOP č. CHA-51
SOP č. CHA-6
SOP č. CHA-68
SOP č. CHA-69
SOP č. CHA-7
SOP č. CHA-70
SOP č. CHA-71
SOP č. CHA-8
SOP č. CHA-9
SOP č. DV-1
SOP č. DV-10
SOP č. DV-11
SOP č. DV-12
SOP č. DV-13
SOP č. DV-14
SOP č. DV-15
SOP č. DV-16
SOP č. DV-17
SOP č. DV-18
SOP č. DV-2
SOP č. DV-21
SOP č. DV-22
SOP č. DV-23
SOP č. DV-24
SOP č. DV-25
SOP č. DV-27
SOP č. DV-29
SOP č. DV-3
SOP č. DV-30
SOP č. DV-31
SOP č. DV-4
SOP č. DV-5
SOP č. DV-6
SOP č. DV-62
SOP č. DV-7
SOP č. DV-8
SOP č. DV-9
SOP č. DV-90
SOP č. DV-91
SOP č. DV-94
SOP č. DV-95
SOP č. DV–101 - část A
SOP č. DV–101 - část B
SOP č. DV–101 - část C
SOP č. DV–101 - část D
SOP č. DV–102 - část A
SOP č. DV–102 - část B
SOP č. DV–102 - část C
SOP č. DV–102 - část D
SOP č. DV–102 - část E
SOP č. DV–103 - část A
SOP č. DV–103 - část B
SOP č. DV–103 - část C
SOP č. DV–103 - část D
SOP č. LP-1
SOP č. LP-10
SOP č. LP-11
SOP č. LP-12
SOP č. LP-13
SOP č. LP-14
SOP č. LP-15
SOP č. LP-16
SOP č. LP-17
SOP č. LP-18
SOP č. LP-19
SOP č. LP-2
SOP č. LP-20
SOP č. LP-21
SOP č. LP-22
SOP č. LP-23
SOP č. LP-24
SOP č. LP-3
SOP č. LP-4
SOP č. LP-5
SOP č. LP-6
SOP č. LP-7
SOP č. LP-8
SOP č. LP-9
SOP č. LPM-1
SOP č. LPM-2
SOP č. LPM-3
SOP č. LPM-4
SOP č. LPM-5
SOP č. LPM-7
SOP č. MB I/10
SOP č. MB I/11
SOP č. MB I/12
SOP č. MB I/13
SOP č. MB I/14
SOP č. MB I/15
SOP č. MB I/16
SOP č. MB I/17
SOP č. MB I/19
SOP č. MB I/20
SOP č. MB I/21
SOP č. MB I/22
SOP č. MB I/23
SOP č. MB I/24
SOP č. MB I/4
SOP č. MB I/6
SOP č. MB I/8
SOP č. MB-I-11
SOP č. MB-I-12
SOP č. MB-I-13
SOP č. MB-I-14
SOP č. MB-I-4
SOP č. MB-I-6
SOP č. MB-I-8
SOP č. MB-I-9
SOP č. OV-1, vyjma kap. 6.1 až 6.3
SOP č. OV-1, vyjma kap. 6.1, 6.2, 6.4
SOP č. OV-1, vyjma kap. 6.1, 6.3, 6.4
SOP č. OV-1, vyjma kap. 6.2 až 6.4
SOP č. SAK-1
SOP č. SAK-100
SOP č. SAK-16
SOP č. SAK-20
SOP č. SAK-21
SOP č. SAK-22
SOP č. SAK-23
SOP č. SAK-24
SOP č. SAK-28
SOP č. SAK-3
SOP č. SAK-30 - část A
SOP č. SAK-30 - část B
SOP č. SAK-5
SOP č. SAK-6
SOP č. SAK-7
SOP č. SAK-71
SOP č. SAK-72
SOP č. SAK-73
SOP č. SAK-79
SOP č. SAK-92
SOP č. SAK-95
SOP č. VP-1, vyjma kap. 5.1, 5.2, 5.3, 5.5, 5.6
SOP č. VP-1, vyjma kap. 5.1, 5.4
SOP č. VP-1, vyjma kap. 5.2 až 5.7
SOP č. VZ-1, vyjma kap. 6.1 až 6.5
SOP č. VZ-1, vyjma kap. 6.1, 6.2, 6.3, 6.6
SOP č. VZ-1, vyjma kap. 6.1, 6.2, 6.4 až 6.6
SOP č. VZ-1, vyjma kap. 6.1, 6.2, 6.5, 6.6
SOP č. VZ-1, vyjma kap. 6.3 až 6.6
TNI CEN/TR 15310-1
TNI CEN/TR 15310-2
TNI CEN/TR 15310-3
TNI CEN/TR 15310-4
TNI CEN/TR 15310-5
Technické doporučení II-E-22, Hydroprojekt, 2003
Vyhláška č. 238/2011 Sb.
Vyhláška č. 252/2004 Sb., příloha č. 6 ve znění Vyhlášky 70/2018 Sb.
Wanner J. a kol.: Biologická kontrola čistíren odpadních vod, SOVAK ČR, 2019
aplikační list QuEChERS firmy Agilent Technologies
aplikační listy firmy Agilent Technologies
návod firmy Hach
návod firmy Hach, ČSN ISO 17289
návod firmy Merck
ČSN 01 5111
ČSN 46 5735
ČSN 65 0342
ČSN 75 7315
ČSN 75 7340
ČSN 75 7342
ČSN 75 7346
ČSN 75 7347
ČSN 75 7350
ČSN 75 7360
ČSN 75 7367
ČSN 75 7372
ČSN 75 7373
ČSN 75 7415
ČSN 75 7440
ČSN 75 7477
ČSN 75 7505
ČSN 75 7506
ČSN 75 7509
ČSN 75 7536
ČSN 75 7712
ČSN 75 7713
ČSN 75 7835
ČSN 75 7837
ČSN 75 7841
ČSN 75 7842
ČSN 83 0520-20: 1978, metoda C
ČSN EN 12485
ČSN EN 12880
ČSN EN 1302
ČSN EN 1302:2000
ČSN EN 13342
ČSN EN 14039
ČSN EN 1484
ČSN EN 14899
ČSN EN 14899, TNI CEN/TR 15310-1
ČSN EN 15934
ČSN EN 15935
ČSN EN 16166
ČSN EN 1622
ČSN EN 17215
ČSN EN 17503
ČSN EN 1899-2
ČSN EN 25663
ČSN EN 26461-2
ČSN EN 26777
ČSN EN 27888
ČSN EN 872
ČSN EN 901
ČSN EN 902
ČSN EN 903
ČSN EN ISO 10304-1
ČSN EN ISO 10304-4
ČSN EN ISO 10390
ČSN EN ISO 10705-2
ČSN EN ISO 10705-3
ČSN EN ISO 11731
ČSN EN ISO 11732
ČSN EN ISO 11885
ČSN EN ISO 13395
ČSN EN ISO 14189
ČSN EN ISO 15061
ČSN EN ISO 15681-2
ČSN EN ISO 16266
ČSN EN ISO 17294-1
ČSN EN ISO 17294-2
ČSN EN ISO 17993
ČSN EN ISO 19458
ČSN EN ISO 20236
ČSN EN ISO 22036
ČSN EN ISO 5667-1
ČSN EN ISO 5667-13
ČSN EN ISO 5667-14
ČSN EN ISO 5667-15
ČSN EN ISO 5667-3
ČSN EN ISO 5667-6
ČSN EN ISO 5814
ČSN EN ISO 5815-1
ČSN EN ISO 6222
ČSN EN ISO 6878
ČSN EN ISO 6888-1
ČSN EN ISO 7027-1
ČSN EN ISO 7393-2
ČSN EN ISO 7887, metoda C
ČSN EN ISO 7899-2
ČSN EN ISO 8467
ČSN EN ISO 8467 a modifikovaná Schulz-Pappova metoda dle JAM, 1965, 114
ČSN EN ISO 9308-1
ČSN EN ISO 9308-2
ČSN EN ISO 9377-2
ČSN EN ISO 9562
ČSN EN ISO 9963-1
ČSN ISO 10 566
ČSN ISO 10523
ČSN ISO 15705
ČSN ISO 17289
ČSN ISO 19250
ČSN ISO 21458
ČSN ISO 21676
ČSN ISO 5664
ČSN ISO 5667-10
ČSN ISO 5667-11
ČSN ISO 5667-21
ČSN ISO 5667-4 kap. 12
ČSN ISO 5667-5
ČSN ISO 6058
ČSN ISO 6059
ČSN ISO 6060
ČSN ISO 6332
ČSN ISO 7150-1
ČSN ISO 7890-3
ČSN ISO 9297

The same scope as data (JSON): https://labcoda.pl/api/accreditation-scopes/labs/CZ/1247