🇨🇿 Horský s.r.o. PL

ČIA 1207 • Praha 9, Czech Republic • 25 methods

Construction

Horský s.r.o. is a laboratory accredited by ČIA under number 1207 (Praha 9, Czech Republic). Its accreditation scope covers 25 test methods in the following areas: Construction. Test objects include: Hardened concrete, Fresh concrete, Grout, Concrete structures and components. Most frequently used techniques: High electrical voltage (spark test), Pressure methods, Rebound hammer.

At a glance

  • Accreditation number: ČIA 1207
  • Methods in scope: 25
  • Types of test objects: 10
  • Techniques used: 3
  • City: Praha 9, Czech Republic
  • Valid until: 20-12-2026
Accreditation number
1207
Accreditation body
ČIA
Address
Klánovická 286/12, 198 00 Praha 9
City
Praha 9, Czech Republic
Division
Laboratorium Horský
Valid until
20-12-2026

What this laboratory tests (10)

Analytical techniques used (3)

Certificate information

Certificate date
20.12.2021

Accreditation scope — test methods (25)

No. Test object Methodology / Parameters Technique Reference document
Test methods
1 Fresh concrete Slump test ČSN EN 12350-2
2 Fresh concrete Flow table test ČSN EN 12350-5
3 Fresh concrete Determination of density ČSN EN 12350-6
4 Fresh concrete Determination of air content - pressure methods Pressure methods ČSN EN 12350-7, mimo čl. 5
5 Hardened concrete Determination of compressive strength ČSN EN 12390-3
6 Hardened concrete Determination of flexural strength of test specimens ČSN EN 12390-5
7 Hardened concrete Determination of density ČSN EN 12390-7
8 Hardened concrete Determination of depth of penetration of water under pressure ČSN EN 12390-8
9 Hardened concrete Determination of air void characteristics ČSN EN 480-11
10 Hardened concrete Determination of frost resistance ČSN 73 1322
11 Hardened concrete; surface-treated concrete Determination of surface resistance to water and chemical de-icing agents (CHRL) ČSN 73 1326, metoda A, C
12 Hardened concrete Determination of adhesion of layers and tensile strength of surface layers ČSN 73 6242, příl. B
13 Hardened concrete Determination of bond strength by pull-off test ČSN EN 1542
14 Hardened concrete Determination of static modulus of elasticity in compression ČSN ISO 1920-10
15 Concrete structures and components Examination and testing of cores in compression ČSN EN 12504-1
16 Hardened concrete Determination of hardness by rebound hammer Rebound hammer ČSN 73 1373; ČSN EN 12504-2
17 Hardened concrete, insulating coating Layer impermeability test ČSN 736242, příl. D
18 Insulating or sealing layer on concrete Layer impermeability test by high electrical voltage (spark test) High electrical voltage (spark test) ČSN 736242, příl. E
19 Waterproofing sheets Determination of tensile adhesion ČSN EN 13596
20 Grout Sieve test, fluidity test ČSN EN 445, čl. 4.2, 4.3
21 Grout Volume change and bleeding test – vertical tube method ČSN EN 445, čl. 4.5
22 Grout Compressive strength test ČSN EN 445, čl. 4.6
23 Grout Volume test ČSN EN 445, čl. 4.7
24 Mortar Determination of compressive strength ČSN EN 12190
25 Soils and bulk materials Compaction check – static load test ČSN 72 1006, příl. A, B, D

Reference standards (26)

ČSN 72 1006, příl. A, B, D
ČSN 73 1322
ČSN 73 1326, metoda A, C
ČSN 73 1373
ČSN 73 6242, příl. B
ČSN 736242, příl. D
ČSN 736242, příl. E
ČSN EN 12190
ČSN EN 12350-2
ČSN EN 12350-5
ČSN EN 12350-6
ČSN EN 12350-7, mimo čl. 5
ČSN EN 12390-3
ČSN EN 12390-5
ČSN EN 12390-7
ČSN EN 12390-8
ČSN EN 12504-1
ČSN EN 12504-2
ČSN EN 13596
ČSN EN 1542
ČSN EN 445, čl. 4.2, 4.3
ČSN EN 445, čl. 4.5
ČSN EN 445, čl. 4.6
ČSN EN 445, čl. 4.7
ČSN EN 480-11
ČSN ISO 1920-10

The same scope as data (JSON): https://labcoda.pl/api/accreditation-scopes/labs/CZ/1207