{"lab":{"_id":"69ad52a4de79e566650fd2ea","accr_number":"1207","country":"CZ","accr_body":"ČIA","address":"Klánovická 286/12, 198 00 Praha 9","categories":["construction"],"city":"Praha 9","imported_at":"2026-03-08T10:42:44.590Z","methods_count":25,"name":"Horský s.r.o.","parse_status":"parsed","parse_version":5,"pdf_files":["1207_670_2021_CS.pdf","1207_670_2021_EN.pdf"],"scope_summary":"Badania właściwości materiałów budowlanych, mas, konstrukcji betonowych, izolacji i gruntów.","search_text":"horský s.r.o. klánovická 286/12, 198 00 praha 9 1207","status":"active","updated_at":"2026-03-08T14:52:09.061Z","valid_from":"","valid_until":"20-12-2026","website":"www.horsky.cz","location":{"type":"Point","coordinates":[14.4378,50.0755]},"email_confidence":"high","email_mx":true,"email_source":"https://www.horsky.cz/kontakty","map_coord":[50.104755,14.538952],"map_geo":"nominatim-street","certificate_date":"20.12.2021","certificate_no":"670/2021","certificate_replaces":"","en_official":false,"fields_of_testing":[{"codes":"","pl":"Badania właściwości materiałów budowlanych, mas, konstrukcji betonowych, izolacji i gruntów.","en":"Testing of properties of building materials, compounds, concrete structures, insulations and soils.","zh":"建筑材料、材料、混凝土结构、保温隔离层和土壤性能的检测。","cs":"Zkoušení vlastností stavebních materiálů, hmot, betonových konstrukcí, izolací a zemin."}],"flexible_scope":false,"flexible_scope_url":null,"has_en":true,"has_zh":true,"lab_division":"Laboratorium Horský","lab_division_cs":"Laboratoř Horský","lab_division_en":"Horský Laboratory","lab_division_zh":"Horský实验室","parse_date":"2026-09-28T12:00:00.000Z","parse_source":"reczna-analiza-labcoda-3","parsed_at":"2026-09-28T12:00:00.000Z","scope_legend":[],"scope_notes":[],"source_lang":"cs","source_pdf_sha256":"7415e478701e7d474a46ad2e77c988edee6edb66e1cb360da285268c2a412da2","source_pdf_url":"https://www.cai.cz/OA/pdf/P670_2021_CS.pdf","source_pdf_url_en":null},"methods":[{"_id":"5607ef29d568d64885fa3ae5","lab_id":"69ad52a4de79e566650fd2ea","country":"CZ","accr_number":"1207","accr_body":"ČIA","row_label":"1","test_object":"Beton świeży","test_object_en":"Fresh concrete","test_object_zh":"新拌混凝土","test_object_cs":"Čerstvý beton","methodology":"Badanie metodą opadu stożka","methodology_en":"Slump test","methodology_zh":"坍落度试验","methodology_cs":"Zkouška sednutím","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Badanie metodą opadu stożka","reference":"ČSN EN 12350-2","norm_bases":["ČSN EN 12350-2"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Beton świeży Badanie metodą opadu stożka Čerstvý beton Zkouška sednutím ČSN EN 12350-2 Beton swiezy Badanie metoda opadu stozka Cerstvy beton Zkouska sednutim CSN EN 12350-2","search_en":"Fresh concrete Slump test ČSN EN 12350-2","search_zh":"新拌混凝土 坍落度试验 ČSN EN 12350-2","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":0,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"77d3443d592b8fd5595c11f8","lab_id":"69ad52a4de79e566650fd2ea","country":"CZ","accr_number":"1207","accr_body":"ČIA","row_label":"2","test_object":"Beton świeży","test_object_en":"Fresh concrete","test_object_zh":"新拌混凝土","test_object_cs":"Čerstvý beton","methodology":"Badanie metodą stolika rozpływowego","methodology_en":"Flow table test","methodology_zh":"扩展度试验","methodology_cs":"Zkouška rozlitím","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Badanie metodą stolika rozpływowego","reference":"ČSN EN 12350-5","norm_bases":["ČSN EN 12350-5"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Beton świeży Badanie metodą stolika rozpływowego Čerstvý beton Zkouška rozlitím ČSN EN 12350-5 Beton swiezy Badanie metoda stolika rozplywowego Cerstvy beton Zkouska rozlitim CSN EN 12350-5","search_en":"Fresh concrete Flow table test ČSN EN 12350-5","search_zh":"新拌混凝土 扩展度试验 ČSN EN 12350-5","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":1,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"a075ae7c6b8d3fe11d1ec481","lab_id":"69ad52a4de79e566650fd2ea","country":"CZ","accr_number":"1207","accr_body":"ČIA","row_label":"3","test_object":"Beton świeży","test_object_en":"Fresh concrete","test_object_zh":"新拌混凝土","test_object_cs":"Čerstvý beton","methodology":"Oznaczanie gęstości","methodology_en":"Determination of density","methodology_zh":"密度的测定","methodology_cs":"Stanovení objemové hmotnosti","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie gęstości","reference":"ČSN EN 12350-6","norm_bases":["ČSN EN 12350-6"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Beton świeży Oznaczanie gęstości Čerstvý beton Stanovení objemové hmotnosti ČSN EN 12350-6 Beton swiezy Oznaczanie gestosci Cerstvy beton Stanoveni objemove hmotnosti CSN EN 12350-6","search_en":"Fresh concrete Determination of density ČSN EN 12350-6","search_zh":"新拌混凝土 密度的测定 ČSN EN 12350-6","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":2,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"dfb4736ca47ecc77a2c01cfa","lab_id":"69ad52a4de79e566650fd2ea","country":"CZ","accr_number":"1207","accr_body":"ČIA","row_label":"4","test_object":"Beton świeży","test_object_en":"Fresh concrete","test_object_zh":"新拌混凝土","test_object_cs":"Čerstvý beton","methodology":"Oznaczanie zawartości powietrza - metody ciśnieniowe","methodology_en":"Determination of air content - pressure methods","methodology_zh":"含气量的测定——压力法","methodology_cs":"Stanovení obsahu vzduchu - tlakové metody","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"Metody ciśnieniowe","technique_en":"Pressure methods","technique_zh":"压力法","technique_cs":"tlakové metody","techniques":["Metody ciśnieniowe"],"techniques_en":["Pressure methods"],"techniques_zh":["压力法"],"techniques_cs":["tlakové metody"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości powietrza - metody ciśnieniowe\nMetody ciśnieniowe","reference":"ČSN EN 12350-7, mimo čl. 5","norm_bases":["ČSN EN 12350-7, mimo čl. 5"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Beton świeży Oznaczanie zawartości powietrza - metody ciśnieniowe Metody ciśnieniowe Čerstvý beton Stanovení obsahu vzduchu - tlakové metody tlakové metody ČSN EN 12350-7, mimo čl. 5 Beton swiezy Oznaczanie zawartosci powietrza - metody cisnieniowe Metody cisnieniowe Cerstvy beton Stanoveni obsahu vzduchu - tlakove metody tlakove metody CSN EN 12350-7, mimo cl. 5","search_en":"Fresh concrete Determination of air content - pressure methods Pressure methods ČSN EN 12350-7, mimo čl. 5","search_zh":"新拌混凝土 含气量的测定——压力法 压力法 ČSN EN 12350-7, mimo čl. 5","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":3,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"4f54fe2830ee469e680b5ddf","lab_id":"69ad52a4de79e566650fd2ea","country":"CZ","accr_number":"1207","accr_body":"ČIA","row_label":"5","test_object":"Beton stwardniały","test_object_en":"Hardened concrete","test_object_zh":"硬化混凝土","test_object_cs":"Ztvrdlý beton","methodology":"Oznaczanie wytrzymałości na ściskanie","methodology_en":"Determination of compressive strength","methodology_zh":"抗压强度的测定","methodology_cs":"Stanovení pevnosti v tlaku","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie wytrzymałości na ściskanie","reference":"ČSN EN 12390-3","norm_bases":["ČSN EN 12390-3"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Beton stwardniały Oznaczanie wytrzymałości na ściskanie Ztvrdlý beton Stanovení pevnosti v tlaku ČSN EN 12390-3 Beton stwardnialy Oznaczanie wytrzymalosci na sciskanie Ztvrdly beton Stanoveni pevnosti v tlaku CSN EN 12390-3","search_en":"Hardened concrete Determination of compressive strength ČSN EN 12390-3","search_zh":"硬化混凝土 抗压强度的测定 ČSN EN 12390-3","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":4,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"e10f664aa079c1b386b6ea93","lab_id":"69ad52a4de79e566650fd2ea","country":"CZ","accr_number":"1207","accr_body":"ČIA","row_label":"6","test_object":"Beton stwardniały","test_object_en":"Hardened concrete","test_object_zh":"硬化混凝土","test_object_cs":"Ztvrdlý beton","methodology":"Oznaczanie wytrzymałości na rozciąganie przy zginaniu próbek","methodology_en":"Determination of flexural strength of test specimens","methodology_zh":"试件抗弯拉强度的测定","methodology_cs":"Stanovení pevnosti v tahu ohybem zkušebních těles","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie wytrzymałości na rozciąganie przy zginaniu próbek","reference":"ČSN EN 12390-5","norm_bases":["ČSN EN 12390-5"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Beton stwardniały Oznaczanie wytrzymałości na rozciąganie przy zginaniu próbek Ztvrdlý beton Stanovení pevnosti v tahu ohybem zkušebních těles ČSN EN 12390-5 Beton stwardnialy Oznaczanie wytrzymalosci na rozciaganie przy zginaniu probek Ztvrdly beton Stanoveni pevnosti v tahu ohybem zkusebnich teles CSN EN 12390-5","search_en":"Hardened concrete Determination of flexural strength of test specimens ČSN EN 12390-5","search_zh":"硬化混凝土 试件抗弯拉强度的测定 ČSN EN 12390-5","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":5,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"9a5a160d4b0bc2e1202bc03e","lab_id":"69ad52a4de79e566650fd2ea","country":"CZ","accr_number":"1207","accr_body":"ČIA","row_label":"7","test_object":"Beton stwardniały","test_object_en":"Hardened concrete","test_object_zh":"硬化混凝土","test_object_cs":"Ztvrdlý beton","methodology":"Oznaczanie gęstości","methodology_en":"Determination of density","methodology_zh":"密度的测定","methodology_cs":"Stanovení objemové hmotnosti","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie gęstości","reference":"ČSN EN 12390-7","norm_bases":["ČSN EN 12390-7"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Beton stwardniały Oznaczanie gęstości Ztvrdlý beton Stanovení objemové hmotnosti ČSN EN 12390-7 Beton stwardnialy Oznaczanie gestosci Ztvrdly beton Stanoveni objemove hmotnosti CSN EN 12390-7","search_en":"Hardened concrete Determination of density ČSN EN 12390-7","search_zh":"硬化混凝土 密度的测定 ČSN EN 12390-7","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":6,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"341554325f74bd1ecdc4256a","lab_id":"69ad52a4de79e566650fd2ea","country":"CZ","accr_number":"1207","accr_body":"ČIA","row_label":"8","test_object":"Beton stwardniały","test_object_en":"Hardened concrete","test_object_zh":"硬化混凝土","test_object_cs":"Ztvrdlý beton","methodology":"Oznaczanie głębokości penetracji wody pod ciśnieniem","methodology_en":"Determination of depth of penetration of water under pressure","methodology_zh":"压力水渗透深度的测定","methodology_cs":"Stanovení hloubky průsaku tlakovou vodou","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie głębokości penetracji wody pod ciśnieniem","reference":"ČSN EN 12390-8","norm_bases":["ČSN EN 12390-8"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Beton stwardniały Oznaczanie głębokości penetracji wody pod ciśnieniem Ztvrdlý beton Stanovení hloubky průsaku tlakovou vodou ČSN EN 12390-8 Beton stwardnialy Oznaczanie glebokosci penetracji wody pod cisnieniem Ztvrdly beton Stanoveni hloubky prusaku tlakovou vodou CSN EN 12390-8","search_en":"Hardened concrete Determination of depth of penetration of water under pressure ČSN EN 12390-8","search_zh":"硬化混凝土 压力水渗透深度的测定 ČSN EN 12390-8","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":7,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"924aaf45b33d739efd988472","lab_id":"69ad52a4de79e566650fd2ea","country":"CZ","accr_number":"1207","accr_body":"ČIA","row_label":"9","test_object":"Beton stwardniały","test_object_en":"Hardened concrete","test_object_zh":"硬化混凝土","test_object_cs":"Ztvrdlý beton","methodology":"Oznaczanie charakterystyki porów powietrznych","methodology_en":"Determination of air void characteristics","methodology_zh":"气孔特征的测定","methodology_cs":"Stanovení charakteristiky vzduchových pórů","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie charakterystyki porów powietrznych","reference":"ČSN EN 480-11","norm_bases":["ČSN EN 480-11"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Beton stwardniały Oznaczanie charakterystyki porów powietrznych Ztvrdlý beton Stanovení charakteristiky vzduchových pórů ČSN EN 480-11 Beton stwardnialy Oznaczanie charakterystyki porow powietrznych Ztvrdly beton Stanoveni charakteristiky vzduchovych poru CSN EN 480-11","search_en":"Hardened concrete Determination of air void characteristics ČSN EN 480-11","search_zh":"硬化混凝土 气孔特征的测定 ČSN EN 480-11","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":8,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"287a8c075c67ebb5b2c3a733","lab_id":"69ad52a4de79e566650fd2ea","country":"CZ","accr_number":"1207","accr_body":"ČIA","row_label":"10","test_object":"Beton stwardniały","test_object_en":"Hardened concrete","test_object_zh":"硬化混凝土","test_object_cs":"Ztvrdlý beton","methodology":"Oznaczanie mrozoodporności","methodology_en":"Determination of frost resistance","methodology_zh":"抗冻性的测定","methodology_cs":"Stanovení mrazuvzdornosti","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie mrozoodporności","reference":"ČSN 73 1322","norm_bases":["ČSN 73 1322"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Beton stwardniały Oznaczanie mrozoodporności Ztvrdlý beton Stanovení mrazuvzdornosti ČSN 73 1322 Beton stwardnialy Oznaczanie mrozoodpornosci Ztvrdly beton Stanoveni mrazuvzdornosti CSN 73 1322","search_en":"Hardened concrete Determination of frost resistance ČSN 73 1322","search_zh":"硬化混凝土 抗冻性的测定 ČSN 73 1322","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":9,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"b6c3fbd3451fd7813ecf815d","lab_id":"69ad52a4de79e566650fd2ea","country":"CZ","accr_number":"1207","accr_body":"ČIA","row_label":"11","test_object":"Beton stwardniały; beton z wykończeniem powierzchni","test_object_en":"Hardened concrete; surface-treated concrete","test_object_zh":"硬化混凝土；表面处理混凝土","test_object_cs":"Ztvrdlý beton; Beton s povrchovou úpravou","methodology":"Oznaczanie odporności powierzchni na działanie wody i chemicznych środków odladzających (CHRL)","methodology_en":"Determination of surface resistance to water and chemical de-icing agents (CHRL)","methodology_zh":"表面抗水和化学除冰剂 (CHRL) 作用能力的测定","methodology_cs":"Stanovení odolnosti povrchu proti působení vody a chemických rozmrazovacích látek (CHRL)","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie odporności powierzchni na działanie wody i chemicznych środków odladzających (CHRL)","reference":"ČSN 73 1326, metoda A, C","norm_bases":["ČSN 73 1326, metoda A, C"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Beton stwardniały; beton z wykończeniem powierzchni Oznaczanie odporności powierzchni na działanie wody i chemicznych środków odladzających (CHRL) Ztvrdlý beton; Beton s povrchovou úpravou Stanovení odolnosti povrchu proti působení vody a chemických rozmrazovacích látek (CHRL) ČSN 73 1326, metoda A, C Beton stwardnialy; beton z wykonczeniem powierzchni Oznaczanie odpornosci powierzchni na dzialanie wody i chemicznych srodkow odladzajacych (CHRL) Ztvrdly beton; Beton s povrchovou upravou Stanoveni odolnosti povrchu proti pusobeni vody a chemickych rozmrazovacich latek (CHRL) CSN 73 1326, metoda A, C","search_en":"Hardened concrete; surface-treated concrete Determination of surface resistance to water and chemical de-icing agents (CHRL) ČSN 73 1326, metoda A, C","search_zh":"硬化混凝土；表面处理混凝土 表面抗水和化学除冰剂 (CHRL) 作用能力的测定 ČSN 73 1326, metoda A, C","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":10,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"6477832c5fa5094fce864953","lab_id":"69ad52a4de79e566650fd2ea","country":"CZ","accr_number":"1207","accr_body":"ČIA","row_label":"12","test_object":"Beton stwardniały","test_object_en":"Hardened concrete","test_object_zh":"硬化混凝土","test_object_cs":"Ztvrdlý beton","methodology":"Oznaczanie przyczepności warstw i wytrzymałości na rozciąganie warstw powierzchniowych","methodology_en":"Determination of adhesion of layers and tensile strength of surface layers","methodology_zh":"层间黏结力和表层抗拉强度的测定","methodology_cs":"Stanovení přilnavosti vrstev a pevnosti v tahu povrchových vrstev","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie przyczepności warstw i wytrzymałości na rozciąganie warstw powierzchniowych","reference":"ČSN 73 6242, příl. B","norm_bases":["ČSN 73 6242, příl. B"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Beton stwardniały Oznaczanie przyczepności warstw i wytrzymałości na rozciąganie warstw powierzchniowych Ztvrdlý beton Stanovení přilnavosti vrstev a pevnosti v tahu povrchových vrstev ČSN 73 6242, příl. B Beton stwardnialy Oznaczanie przyczepnosci warstw i wytrzymalosci na rozciaganie warstw powierzchniowych Ztvrdly beton Stanoveni prilnavosti vrstev a pevnosti v tahu povrchovych vrstev CSN 73 6242, pril. B","search_en":"Hardened concrete Determination of adhesion of layers and tensile strength of surface layers ČSN 73 6242, příl. B","search_zh":"硬化混凝土 层间黏结力和表层抗拉强度的测定 ČSN 73 6242, příl. B","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":11,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"ac0f691e2f60c3392a12ba5d","lab_id":"69ad52a4de79e566650fd2ea","country":"CZ","accr_number":"1207","accr_body":"ČIA","row_label":"13","test_object":"Beton stwardniały","test_object_en":"Hardened concrete","test_object_zh":"硬化混凝土","test_object_cs":"Ztvrdlý beton","methodology":"Oznaczanie przyczepności metodą odrywania (pull-off)","methodology_en":"Determination of bond strength by pull-off test","methodology_zh":"拉拔试验测定黏结强度","methodology_cs":"Stanovení soudržnosti odtrhovou zkouškou","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie przyczepności metodą odrywania (pull-off)","reference":"ČSN EN 1542","norm_bases":["ČSN EN 1542"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Beton stwardniały Oznaczanie przyczepności metodą odrywania (pull-off) Ztvrdlý beton Stanovení soudržnosti odtrhovou zkouškou ČSN EN 1542 Beton stwardnialy Oznaczanie przyczepnosci metoda odrywania (pull-off) Ztvrdly beton Stanoveni soudrznosti odtrhovou zkouskou CSN EN 1542","search_en":"Hardened concrete Determination of bond strength by pull-off test ČSN EN 1542","search_zh":"硬化混凝土 拉拔试验测定黏结强度 ČSN EN 1542","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":12,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"ebebc54344d784a10b42856f","lab_id":"69ad52a4de79e566650fd2ea","country":"CZ","accr_number":"1207","accr_body":"ČIA","row_label":"14","test_object":"Beton stwardniały","test_object_en":"Hardened concrete","test_object_zh":"硬化混凝土","test_object_cs":"Ztvrdlý beton","methodology":"Oznaczanie statycznego modułu sprężystości przy ściskaniu","methodology_en":"Determination of static modulus of elasticity in compression","methodology_zh":"受压静弹性模量的测定","methodology_cs":"Stanovení statického modulu pružnosti v tlaku","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie statycznego modułu sprężystości przy ściskaniu","reference":"ČSN ISO 1920-10","norm_bases":["ČSN ISO 1920-10"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Beton stwardniały Oznaczanie statycznego modułu sprężystości przy ściskaniu Ztvrdlý beton Stanovení statického modulu pružnosti v tlaku ČSN ISO 1920-10 Beton stwardnialy Oznaczanie statycznego modulu sprezystosci przy sciskaniu Ztvrdly beton Stanoveni statickeho modulu pruznosti v tlaku CSN ISO 1920-10","search_en":"Hardened concrete Determination of static modulus of elasticity in compression ČSN ISO 1920-10","search_zh":"硬化混凝土 受压静弹性模量的测定 ČSN ISO 1920-10","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":13,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"e5f5eb8fb2a296812e419c6b","lab_id":"69ad52a4de79e566650fd2ea","country":"CZ","accr_number":"1207","accr_body":"ČIA","row_label":"15","test_object":"Konstrukcje i elementy betonowe","test_object_en":"Concrete structures and components","test_object_zh":"混凝土结构和构件","test_object_cs":"Betonové konstrukce a dílce","methodology":"Badanie i próby odwiertów rdzeniowych na ściskanie","methodology_en":"Examination and testing of cores in compression","methodology_zh":"芯样检查和抗压试验","methodology_cs":"Vyšetřování a zkoušení vývrtů v tlaku","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Badanie i próby odwiertów rdzeniowych na ściskanie","reference":"ČSN EN 12504-1","norm_bases":["ČSN EN 12504-1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Konstrukcje i elementy betonowe Badanie i próby odwiertów rdzeniowych na ściskanie Betonové konstrukce a dílce Vyšetřování a zkoušení vývrtů v tlaku ČSN EN 12504-1 Konstrukcje i elementy betonowe Badanie i proby odwiertow rdzeniowych na sciskanie Betonove konstrukce a dilce Vysetrovani a zkouseni vyvrtu v tlaku CSN EN 12504-1","search_en":"Concrete structures and components Examination and testing of cores in compression ČSN EN 12504-1","search_zh":"混凝土结构和构件 芯样检查和抗压试验 ČSN EN 12504-1","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":14,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"238dbe8c743ad64d3f6ca4b5","lab_id":"69ad52a4de79e566650fd2ea","country":"CZ","accr_number":"1207","accr_body":"ČIA","row_label":"16","test_object":"Beton stwardniały","test_object_en":"Hardened concrete","test_object_zh":"硬化混凝土","test_object_cs":"Ztvrdlý beton","methodology":"Oznaczanie twardości sklerometrem (młotkiem odbiciowym)","methodology_en":"Determination of hardness by rebound hammer","methodology_zh":"回弹仪测定硬度","methodology_cs":"Stanovení tvrdosti odrazovým tvrdoměrem","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"Sklerometr (młotek odbiciowy)","technique_en":"Rebound hammer","technique_zh":"回弹仪","technique_cs":"odrazovým tvrdoměrem","techniques":["Sklerometr (młotek odbiciowy)"],"techniques_en":["Rebound hammer"],"techniques_zh":["回弹仪"],"techniques_cs":["odrazovým tvrdoměrem"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie twardości sklerometrem (młotkiem odbiciowym)\nSklerometr (młotek odbiciowy)","reference":"ČSN 73 1373; ČSN EN 12504-2","norm_bases":["ČSN 73 1373","ČSN EN 12504-2"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Beton stwardniały Oznaczanie twardości sklerometrem (młotkiem odbiciowym) Sklerometr (młotek odbiciowy) Ztvrdlý beton Stanovení tvrdosti odrazovým tvrdoměrem odrazovým tvrdoměrem ČSN 73 1373; ČSN EN 12504-2 Beton stwardnialy Oznaczanie twardosci sklerometrem (mlotkiem odbiciowym) Sklerometr (mlotek odbiciowy) Ztvrdly beton Stanoveni tvrdosti odrazovym tvrdomerem odrazovym tvrdomerem CSN 73 1373; CSN EN 12504-2","search_en":"Hardened concrete Determination of hardness by rebound hammer Rebound hammer ČSN 73 1373; ČSN EN 12504-2","search_zh":"硬化混凝土 回弹仪测定硬度 回弹仪 ČSN 73 1373; ČSN EN 12504-2","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":15,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"8e34c54681e50a62bc347de1","lab_id":"69ad52a4de79e566650fd2ea","country":"CZ","accr_number":"1207","accr_body":"ČIA","row_label":"17","test_object":"Beton stwardniały, powłoka izolacyjna","test_object_en":"Hardened concrete, insulating coating","test_object_zh":"硬化混凝土、隔离涂层","test_object_cs":"Ztvrdlý beton, izolační povlak","methodology":"Badanie szczelności warstwy","methodology_en":"Layer impermeability test","methodology_zh":"层不透水性试验","methodology_cs":"Zkouška nepropustnosti vrstvy","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Badanie szczelności warstwy","reference":"ČSN 736242, příl. D","norm_bases":["ČSN 736242, příl. D"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Beton stwardniały, powłoka izolacyjna Badanie szczelności warstwy Ztvrdlý beton, izolační povlak Zkouška nepropustnosti vrstvy ČSN 736242, příl. D Beton stwardnialy, powloka izolacyjna Badanie szczelnosci warstwy Ztvrdly beton, izolacni povlak Zkouska nepropustnosti vrstvy CSN 736242, pril. D","search_en":"Hardened concrete, insulating coating Layer impermeability test ČSN 736242, příl. D","search_zh":"硬化混凝土、隔离涂层 层不透水性试验 ČSN 736242, příl. D","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":16,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"5f1196959346f701bdac31ba","lab_id":"69ad52a4de79e566650fd2ea","country":"CZ","accr_number":"1207","accr_body":"ČIA","row_label":"18","test_object":"Warstwa izolacyjna lub uszczelniająca na betonie","test_object_en":"Insulating or sealing layer on concrete","test_object_zh":"混凝土上的隔离层或密封层","test_object_cs":"Izolační nebo pečetící vrstva na betonu","methodology":"Badanie szczelności warstwy wysokim napięciem elektrycznym (próba iskrowa)","methodology_en":"Layer impermeability test by high electrical voltage (spark test)","methodology_zh":"高压电法层不透水性试验（电火花试验）","methodology_cs":"Zkouška nepropustnosti vrstvy vysokým elektrickým napětím (jiskrová zkouška)","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"Wysokie napięcie elektryczne (próba iskrowa)","technique_en":"High electrical voltage (spark test)","technique_zh":"高压电（电火花试验）","technique_cs":"vysokým elektrickým napětím (jiskrová zkouška)","techniques":["Wysokie napięcie elektryczne (próba iskrowa)"],"techniques_en":["High electrical voltage (spark test)"],"techniques_zh":["高压电（电火花试验）"],"techniques_cs":["vysokým elektrickým napětím (jiskrová zkouška)"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Badanie szczelności warstwy wysokim napięciem elektrycznym (próba iskrowa)\nWysokie napięcie elektryczne (próba iskrowa)","reference":"ČSN 736242, příl. E","norm_bases":["ČSN 736242, příl. E"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Warstwa izolacyjna lub uszczelniająca na betonie Badanie szczelności warstwy wysokim napięciem elektrycznym (próba iskrowa) Wysokie napięcie elektryczne (próba iskrowa) Izolační nebo pečetící vrstva na betonu Zkouška nepropustnosti vrstvy vysokým elektrickým napětím (jiskrová zkouška) vysokým elektrickým napětím (jiskrová zkouška) ČSN 736242, příl. E Warstwa izolacyjna lub uszczelniajaca na betonie Badanie szczelnosci warstwy wysokim napieciem elektrycznym (proba iskrowa) Wysokie napiecie elektryczne (proba iskrowa) Izolacni nebo pecetici vrstva na betonu Zkouska nepropustnosti vrstvy vysokym elektrickym napetim (jiskrova zkouska) vysokym elektrickym napetim (jiskrova zkouska) CSN 736242, pril. E","search_en":"Insulating or sealing layer on concrete Layer impermeability test by high electrical voltage (spark test) High electrical voltage (spark test) ČSN 736242, příl. E","search_zh":"混凝土上的隔离层或密封层 高压电法层不透水性试验（电火花试验） 高压电（电火花试验） ČSN 736242, příl. E","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":17,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"9b5c103538b83681b6aa3834","lab_id":"69ad52a4de79e566650fd2ea","country":"CZ","accr_number":"1207","accr_body":"ČIA","row_label":"19","test_object":"Pasy hydroizolacyjne","test_object_en":"Waterproofing sheets","test_object_zh":"防水卷材","test_object_cs":"Hydroizolační pásy","methodology":"Oznaczanie przyczepności przy rozciąganiu","methodology_en":"Determination of tensile adhesion","methodology_zh":"拉伸黏结力的测定","methodology_cs":"Stanovení přilnavosti v tahu","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie przyczepności przy rozciąganiu","reference":"ČSN EN 13596","norm_bases":["ČSN EN 13596"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Pasy hydroizolacyjne Oznaczanie przyczepności przy rozciąganiu Hydroizolační pásy Stanovení přilnavosti v tahu ČSN EN 13596 Pasy hydroizolacyjne Oznaczanie przyczepnosci przy rozciaganiu Hydroizolacni pasy Stanoveni prilnavosti v tahu CSN EN 13596","search_en":"Waterproofing sheets Determination of tensile adhesion ČSN EN 13596","search_zh":"防水卷材 拉伸黏结力的测定 ČSN EN 13596","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":18,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"4b3b9cb99b98369fefb7b43e","lab_id":"69ad52a4de79e566650fd2ea","country":"CZ","accr_number":"1207","accr_body":"ČIA","row_label":"20","test_object":"Zaczyn iniekcyjny","test_object_en":"Grout","test_object_zh":"灌浆料","test_object_cs":"Injektážní malta","methodology":"Badanie na sicie, badanie płynności","methodology_en":"Sieve test, fluidity test","methodology_zh":"筛分试验、流动性试验","methodology_cs":"Sítová zkouška, zkouška tekutosti","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Badanie na sicie, badanie płynności","reference":"ČSN EN 445, čl. 4.2, 4.3","norm_bases":["ČSN EN 445, čl. 4.2, 4.3"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Zaczyn iniekcyjny Badanie na sicie, badanie płynności Injektážní malta Sítová zkouška, zkouška tekutosti ČSN EN 445, čl. 4.2, 4.3 Zaczyn iniekcyjny Badanie na sicie, badanie plynnosci Injektazni malta Sitova zkouska, zkouska tekutosti CSN EN 445, cl. 4.2, 4.3","search_en":"Grout Sieve test, fluidity test ČSN EN 445, čl. 4.2, 4.3","search_zh":"灌浆料 筛分试验、流动性试验 ČSN EN 445, čl. 4.2, 4.3","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":19,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"d43bcea56fa714d6e931eca2","lab_id":"69ad52a4de79e566650fd2ea","country":"CZ","accr_number":"1207","accr_body":"ČIA","row_label":"21","test_object":"Zaczyn iniekcyjny","test_object_en":"Grout","test_object_zh":"灌浆料","test_object_cs":"Injektážní malta","methodology":"Badanie zmiany objętości i odsączania wody – metoda rury pionowej","methodology_en":"Volume change and bleeding test – vertical tube method","methodology_zh":"体积变化和泌水试验——垂直管法","methodology_cs":"Zkouška objemové změny a odlučování vody – metoda svislé trubice","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Badanie zmiany objętości i odsączania wody – metoda rury pionowej","reference":"ČSN EN 445, čl. 4.5","norm_bases":["ČSN EN 445, čl. 4.5"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Zaczyn iniekcyjny Badanie zmiany objętości i odsączania wody – metoda rury pionowej Injektážní malta Zkouška objemové změny a odlučování vody – metoda svislé trubice ČSN EN 445, čl. 4.5 Zaczyn iniekcyjny Badanie zmiany objetosci i odsaczania wody – metoda rury pionowej Injektazni malta Zkouska objemove zmeny a odlucovani vody – metoda svisle trubice CSN EN 445, cl. 4.5","search_en":"Grout Volume change and bleeding test – vertical tube method ČSN EN 445, čl. 4.5","search_zh":"灌浆料 体积变化和泌水试验——垂直管法 ČSN EN 445, čl. 4.5","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":20,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"570069f4688b96bd6b71da5f","lab_id":"69ad52a4de79e566650fd2ea","country":"CZ","accr_number":"1207","accr_body":"ČIA","row_label":"22","test_object":"Zaczyn iniekcyjny","test_object_en":"Grout","test_object_zh":"灌浆料","test_object_cs":"Injektážní malta","methodology":"Badanie wytrzymałości na ściskanie","methodology_en":"Compressive strength test","methodology_zh":"抗压强度试验","methodology_cs":"Zkouška pevnosti v tlaku","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Badanie wytrzymałości na ściskanie","reference":"ČSN EN 445, čl. 4.6","norm_bases":["ČSN EN 445, čl. 4.6"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Zaczyn iniekcyjny Badanie wytrzymałości na ściskanie Injektážní malta Zkouška pevnosti v tlaku ČSN EN 445, čl. 4.6 Zaczyn iniekcyjny Badanie wytrzymalosci na sciskanie Injektazni malta Zkouska pevnosti v tlaku CSN EN 445, cl. 4.6","search_en":"Grout Compressive strength test ČSN EN 445, čl. 4.6","search_zh":"灌浆料 抗压强度试验 ČSN EN 445, čl. 4.6","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":21,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"8feb4b671e3720fd78db1bf1","lab_id":"69ad52a4de79e566650fd2ea","country":"CZ","accr_number":"1207","accr_body":"ČIA","row_label":"23","test_object":"Zaczyn iniekcyjny","test_object_en":"Grout","test_object_zh":"灌浆料","test_object_cs":"Injektážní malta","methodology":"Badanie objętości","methodology_en":"Volume test","methodology_zh":"体积试验","methodology_cs":"Zkouška objemu","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Badanie objętości","reference":"ČSN EN 445, čl. 4.7","norm_bases":["ČSN EN 445, čl. 4.7"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Zaczyn iniekcyjny Badanie objętości Injektážní malta Zkouška objemu ČSN EN 445, čl. 4.7 Zaczyn iniekcyjny Badanie objetosci Injektazni malta Zkouska objemu CSN EN 445, cl. 4.7","search_en":"Grout Volume test ČSN EN 445, čl. 4.7","search_zh":"灌浆料 体积试验 ČSN EN 445, čl. 4.7","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":22,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"0c78699721ad4542259c1ce2","lab_id":"69ad52a4de79e566650fd2ea","country":"CZ","accr_number":"1207","accr_body":"ČIA","row_label":"24","test_object":"Zaprawa","test_object_en":"Mortar","test_object_zh":"砂浆","test_object_cs":"Malta","methodology":"Oznaczanie wytrzymałości na ściskanie","methodology_en":"Determination of compressive strength","methodology_zh":"抗压强度的测定","methodology_cs":"Stanovení pevnosti v tlaku","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie wytrzymałości na ściskanie","reference":"ČSN EN 12190","norm_bases":["ČSN EN 12190"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Zaprawa Oznaczanie wytrzymałości na ściskanie Malta Stanovení pevnosti v tlaku ČSN EN 12190 Zaprawa Oznaczanie wytrzymalosci na sciskanie Malta Stanoveni pevnosti v tlaku CSN EN 12190","search_en":"Mortar Determination of compressive strength ČSN EN 12190","search_zh":"砂浆 抗压强度的测定 ČSN EN 12190","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":23,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"a25633059c664d4b1d4ecdca","lab_id":"69ad52a4de79e566650fd2ea","country":"CZ","accr_number":"1207","accr_body":"ČIA","row_label":"25","test_object":"Grunty i materiały sypkie","test_object_en":"Soils and bulk materials","test_object_zh":"土壤和散体材料","test_object_cs":"Zeminy a sypaniny","methodology":"Kontrola zagęszczenia – statyczne badanie płytą obciążeniową","methodology_en":"Compaction check – static load test","methodology_zh":"压实度检查——静载试验","methodology_cs":"Kontrola zhutnění – statická zatěžovací zkouška","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Kontrola zagęszczenia – statyczne badanie płytą obciążeniową","reference":"ČSN 72 1006, příl. A, B, D","norm_bases":["ČSN 72 1006, příl. A, B, D"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Grunty i materiały sypkie Kontrola zagęszczenia – statyczne badanie płytą obciążeniową Zeminy a sypaniny Kontrola zhutnění – statická zatěžovací zkouška ČSN 72 1006, příl. A, B, D Grunty i materialy sypkie Kontrola zageszczenia – statyczne badanie plyta obciazeniowa Zeminy a sypaniny Kontrola zhutneni – staticka zatezovaci zkouska CSN 72 1006, pril. A, B, D","search_en":"Soils and bulk materials Compaction check – static load test ČSN 72 1006, příl. A, B, D","search_zh":"土壤和散体材料 压实度检查——静载试验 ČSN 72 1006, příl. A, B, D","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":24,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"}],"has_pdf":true}