🇨🇿 VODÁRNA PLZEŇ a.s. PL

ČIA 1202 • Plzeň, Czech Republic • 80 methods

Water & wastewaterEnvironmentMicrobiology

VODÁRNA PLZEŇ a.s. is a laboratory accredited by ČIA under number 1202 (Plzeň, Czech Republic). Its accreditation scope covers 80 test methods in the following areas: Water & wastewater, Environment, Microbiology. Test objects include: Drinking water, raw water (surface, ground), service water, Drinking water, raw water (surface, ground), service water, waste w…, Sludge, sediment, screenings, sand, soil, Drinking water, raw water (surface, ground), service water, waste w…. Most frequently used techniques: by gravimetry, membrane filtration, by photometry.

At a glance

  • Accreditation number: ČIA 1202
  • Methods in scope: 80
  • Types of test objects: 15
  • Techniques used: 30
  • City: Plzeň, Czech Republic
  • Valid until: 04-01-2027
Accreditation number
1202
Accreditation body
ČIA
Address
Malostranská 143/2, Doudlevce, 326 00 Plzeň
City
Plzeň, Czech Republic
Division
zakład Laboratoria
Valid until
04-01-2027

What this laboratory tests (15)

Analytical techniques used (30)

Laboratory sections (2)

Laboratory locations

Certificate information

Certificate date
13.08.2024

Accreditation scope — test methods (80)

No. Test object Methodology / Parameters Technique Reference document
Waste Water Laboratory
1 Drinking water, raw water (surface, ground), service water, waste water, aqueous extract of sludge, sediment, screenings, sand, soil Determination of pH by potentiometry
Regulated area: Waste Water Laboratory – Tests
by potentiometry SOP-O-07/pH část A (ČSN ISO 10523)
2 Sludge, sediment, screenings, sand, soil Determination of pH by potentiometry
Regulated area: Waste Water Laboratory – Tests
by potentiometry SOP-O-07/pH část B (ČSN EN 12176:1999; ČSN EN ISO 10390)
3 Drinking water, raw water (surface, ground), service water, waste water Determination of acid neutralizing capacity by potentiometry (ANC4.5)
Regulated area: Waste Water Laboratory – Tests
by potentiometry SOP-O-08/KNK4.5 část A (ČSN ISO 9963-1)
4 Sludge, sediment, screenings, sand, soil Determination of acid neutralizing capacity by potentiometry (ANC4.5)
Regulated area: Waste Water Laboratory – Tests
by potentiometry SOP-O-08/KNK4.5 část B (ČSN ISO 9963-1)
5 Drinking water, raw water (surface, ground), service water, waste water, aqueous extract of sludge, sediment, screenings, sand, soil Determination of chemical oxygen demand by dichromate, titrimetric (CODCr)
Regulated area: Waste Water Laboratory – Tests
by titration SOP-O-11/CHSKCr část A (ČSN ISO 6060)
6 Sludge Determination of chemical oxygen demand by dichromate, titrimetric (CODCr)
Regulated area: Waste Water Laboratory – Tests
by titration SOP-O-11/CHSKCr část B (ČSN ISO 6060)
7 Drinking water, raw water (surface, ground), service water, waste water, aqueous extract of sludge, sediment, screenings, sand, soil Determination of chemical oxygen demand by dichromate, spectrophotometric - Merck commercial kit (CODCr)
Regulated area: Waste Water Laboratory – Tests
spectrophotometry - Merck commercial kit SOP-O-11/CHSKCr /SP část A (ČSN ISO 15705; návod firmy Merck)
8 Sludge Determination of chemical oxygen demand by dichromate, spectrophotometric - Merck commercial kit (CODCr)
Regulated area: Waste Water Laboratory – Tests
spectrophotometry - Merck commercial kit SOP-O-11/CHSKCr /SP část B (ČSN ISO 15705; návod firmy Merck)
9 Raw water (surface, ground), service water, waste water, aqueous extract of sludge, sediment, screenings, sand, soil Determination of biochemical oxygen demand after n days by optical sensor method (BODn)
Regulated area: Waste Water Laboratory – Tests
optical sensor method SOP-O-13/BSK5 (ČSN EN ISO 5815-1; ČSN EN 1899-2; ČSN ISO 17289)
10 Drinking water, raw water (surface, ground), service water, waste water Determination of total solids, ignited total solids by gravimetry (TS, TSi) and loss on ignition by calculation from measured values (LOI)
loss on ignition by calculation from measured values (calculated)
Regulated area: Waste Water Laboratory – Tests
by gravimetry SOP-O-14/VL, 15/VLž. část A (ČSN 83 0540-3:1979, část A)
11 Sludge, sediment, screenings, sand, soil Determination of total solids, ignited total solids by gravimetry (TS, TSi) and loss on ignition by calculation from measured values (LOI)
loss on ignition by calculation from measured values (calculated)
Regulated area: Waste Water Laboratory – Tests
by gravimetry SOP-O-14/VL, 15/VLž. část B (ČSN EN 12880; ČSN EN 15934; ČSN EN 15935)
12 Drinking water, raw water (surface, ground), service water, waste water Determination of suspended solids, ignited suspended solids by gravimetry (SS, SSi) and loss on ignition by calculation from measured values
loss on ignition by calculation from measured values (calculated)
Regulated area: Waste Water Laboratory – Tests
by gravimetry SOP-O-16/NL, 17/NLž. část A (ČSN EN 872; ČSN 75 7350)
13 Sludge, sediment, screenings, sand, soil Determination of suspended solids, ignited suspended solids by gravimetry (SS, SSi) and loss on ignition by calculation from measured values
loss on ignition by calculation from measured values (calculated)
Regulated area: Waste Water Laboratory – Tests
by gravimetry SOP-O-16/NL, 17/NLž. část B (ČSN EN 872; ČSN 75 7350)
14 Drinking water, raw water (surface, ground), service water, waste water, aqueous extract of sludge, sediment, screenings, sand, soil Determination of dissolved solids, ignited dissolved solids by gravimetry and by calculation from measured values (DS, DSi) and loss on ignition by calculation from measured values
loss on ignition by calculation from measured values (calculated)
Regulated area: Waste Water Laboratory – Tests
by gravimetry SOP-O-18/RL, 19/RLž. (ČSN 75 7346; ČSN 75 7347)
15 Drinking water, raw water (surface, ground), service water, waste water, aqueous extract of sludge, sediment, screenings, sand, soil Determination of ammonium ions by distillation (NH4+), ammonia nitrogen by calculation from measured values (N-NH4+)
ammonia nitrogen by calculation from measured values (N-NH4+) (calculated)
Regulated area: Waste Water Laboratory – Tests
by distillation SOP-O-21a/N-NH4+ část A (ČSN ISO 5664; ČSN 83 0540-10:1985)
16 Sludge, sediment, screenings, sand, soil Determination of ammonium ions by distillation (NH4+), ammonia nitrogen by calculation from measured values (N-NH4+)
ammonia nitrogen by calculation from measured values (N-NH4+) (calculated)
Regulated area: Waste Water Laboratory – Tests
by distillation SOP-O-21a/N-NH4+ část B (ČSN EN 14671; ČSN ISO 5664; ČSN 83 0540-10:1985)
17 Drinking water, raw water (surface, ground), service water, waste water, aqueous extract of sludge, sediment, screenings, sand, soil Determination of Kjeldahl nitrogen by titration (Nk), organic, inorganic and total nitrogen (N org., N inorg., N tot.) by calculation from measured values
organic, inorganic and total nitrogen by calculation from measured values (calculated)
Regulated area: Waste Water Laboratory – Tests
Kjeldahl titration SOP-O-24, 25/N část A (ČSN EN 25663; ČSN 83 0540-13:1985, část C)
18 Sludge, sediment, screenings, sand, soil Determination of Kjeldahl nitrogen by titration (Nk), organic, inorganic and total nitrogen (N org., N inorg., N tot.) by calculation from measured values
organic, inorganic and total nitrogen by calculation from measured values (calculated)
Regulated area: Waste Water Laboratory – Tests
Kjeldahl titration SOP-O-24, 25/N část B (ČSN EN 13342; ČSN EN 16169; ČSN 83 0540-13:1985, část C)
19 Drinking water, raw water (surface, ground), service water, waste water, aqueous extract of sludge, sediment, screenings, sand, soil Determination of ions (NH4+, NO2-, NO3-, PO43-, P tot.) by CFA method, determination of nitrogen forms and inorganic nitrogen (N-NH4+, N-NO2-, N-NO3-, N inorg.) by calculation from measured values
nitrogen forms, inorganic nitrogen by calculation from measured values (calculated)
Regulated area: Waste Water Laboratory – Tests
CFA method SOP-O-86/ionty CFA část A (ČSN EN ISO 11732; ČSN EN ISO 13395; ČSN EN ISO 15681-2)
20 Sludge Determination of ions (NH4+, NO2-, NO3-, PO43-, P tot.) by CFA method, determination of nitrogen forms and inorganic nitrogen (N-NH4+, N-NO2-, N-NO3-, N inorg.) by calculation from measured values
nitrogen forms, inorganic nitrogen by calculation from measured values (calculated)
Regulated area: Waste Water Laboratory – Tests
CFA method SOP-O-86/ionty CFA část B (ČSN EN ISO 11732; ČSN EN ISO 13395; ČSN EN ISO 15681-2; ČSN EN 14671)
21 Drinking water, raw water (surface, ground), service water, waste water, aqueous extract of sludge, sediment, screenings, sand, soil Determination of anionic surfactants by photometry (PAL A)
Regulated area: Waste Water Laboratory – Tests
by photometry SOP-O-28/PAL A (M. Horáková, P. Lischke, A. Grunwald: „Chemické a fyzikální metody analýzy vod“, SNTL Praha, 1986, kap. 2.42.1)
22 Drinking water, raw water (surface, ground), service water, waste water Determination of extractable substances (fats and oils) by gravimetry (EL)
Regulated area: Waste Water Laboratory – Tests
by gravimetry SOP-O-29/EL (ČSN ISO 11349; ČSN 75 7509; ČSN 75 7508)
23 Drinking water, raw water (surface, ground), service water, waste water Determination of adsorbable organic halogens by coulometry after thermal decomposition (AOX)
Regulated area: Waste Water Laboratory – Tests
coulometry after thermal decomposition SOP-O-40/AOX část A (ČSN EN ISO 9562)
24 Sludge, sediment, screenings, sand, soil Determination of adsorbable organic halogens by coulometry after thermal decomposition (AOX)
Regulated area: Waste Water Laboratory – Tests
coulometry after thermal decomposition SOP-O-40/AOX část B (ČSN EN 16166)
25 Drinking water, raw water (surface, ground), service water, waste water, aqueous extract of sludge, sediment, screenings, sand, soil Determination of polycyclic aromatic hydrocarbons (LC with fluorescence detection) (PAH)
fluoranthene benzo[b]fluoranthene benzo[k]fluoranthene benzo[a]pyrene benzo[g,h,i]perylene indeno[1,2,3-c,d]pyrene
sum of PAH – by calculation from measured values (calculated)
Regulated area: Waste Water Laboratory – Tests
LC with fluorescence detection SOP-O-32/analyty HPLC-32/PAU (ČSN EN ISO 17993)
26 Drinking water, raw water (surface, ground), service water, waste water, aqueous extract of sludge, sediment, screenings, sand, soil Determination of chloride by titration (Cl-)
Regulated area: Waste Water Laboratory – Tests
by titration SOP-O-36/Cl- (M. Horáková, P. Lischke, A. Grunwald: „Chemické a fyzikální metody analýzy vod“, SNTL Praha, 1986, kap. 2.22.2)
27 Drinking water, raw water (surface, ground), service water, waste water, aqueous extract of sludge, sediment, screenings, sand, soil Determination of phenols by photometry (FN)
Regulated area: Waste Water Laboratory – Tests
by photometry SOP-O-39/FN (M. Horáková, P. Lischke, A. Grunwald: „Chemické a fyzikální metody analýzy vod“, SNTL Praha, 1986, kap. 2.41.2)
28 Drinking water, raw water (surface, ground), service water Determination of metals by ICP/AES method and hardness by calculation from measured values
Silver (Ag) Aluminium (Al) Boron (B) Barium (Ba) Beryllium (Be) Calcium (Ca) Cadmium (Cd) Cobalt (Co) Chromium (Cr) Copper (Cu) Iron (Fe) Potassium (K) Magnesium (Mg) Manganese (Mn) Molybdenum (Mo) Sodium (Na) Nickel (Ni) Phosphorus (P) Lead (Pb) Silicon (Si) Strontium (Sr) Vanadium (V) Zinc (Zn)
hardness by calculation from measured values (calculated)
Regulated area: Waste Water Laboratory – Tests
ICP/AES method SOP-O-74/kovy ICP AES - 74/kovy část A (ČSN EN ISO 11885)
29 Waste water, aqueous extract of sludge, sediment, screenings, sand, soil Determination of metals by ICP/AES method
Silver (Ag) Aluminium (Al) Boron (B) Barium (Ba) Beryllium (Be) Calcium (Ca) Cadmium (Cd) Cobalt (Co) Chromium (Cr) Copper (Cu) Iron (Fe) Potassium (K) Magnesium (Mg) Manganese (Mn) Molybdenum (Mo) Nickel (Ni) Phosphorus (P) Lead (Pb) Vanadium (V) Zinc (Zn)
Regulated area: Waste Water Laboratory – Tests
ICP/AES method SOP-O-74/kovy ICP AES - 74/kovy část B (ČSN EN ISO 11885)
30 Sludge, sediment, screenings, sand, soil Determination of metals by ICP/AES method
Silver (Ag) Aluminium (Al) Boron (B) Barium (Ba) Beryllium (Be) Calcium (Ca) Cadmium (Cd) Cobalt (Co) Chromium (Cr) Copper (Cu) Iron (Fe) Potassium (K) Magnesium (Mg) Manganese (Mn) Molybdenum (Mo) Nickel (Ni) Phosphorus (P) Lead (Pb) Vanadium (V) Zinc (Zn)
Regulated area: Waste Water Laboratory – Tests
ICP/AES method SOP-O-74/kovy ICP AES - 74/kovy část C (ČSN EN ISO 11885; ČSN EN 16173; ČSN EN 16170; ČSN EN ISO 54321)
31 Drinking water, raw water (surface, ground), service water Determination of metals (As, Sb, Sn, Se) by hydride ICP/AES method
Arsenic (As) Antimony (Sb) Tin (Sn) Selenium (Se)
Regulated area: Waste Water Laboratory – Tests
hydride ICP/AES method SOP-O-74/kovy ICP AES - 74/kovy část D (ČSN EN ISO 11885)
32 Waste water, aqueous extract of sludge, sediment, screenings, sand, soil Determination of metals (As, Sb, Sn, Se) by hydride ICP/AES method
Arsenic (As) Antimony (Sb) Tin (Sn) Selenium (Se)
Regulated area: Waste Water Laboratory – Tests
hydride ICP/AES method SOP-O-74/kovy ICP AES - 74/kovy část E (ČSN EN ISO 11885)
33 Sludge, sediment, screenings, sand, soil Determination of metals (As, Sb, Sn, Se) by hydride ICP/AES method
Arsenic (As) Antimony (Sb) Tin (Sn) Selenium (Se)
Regulated area: Waste Water Laboratory – Tests
hydride ICP/AES method SOP-O-74/kovy ICP AES - 74/kovy část F (ČSN EN ISO 11885; ČSN EN 16173; ČSN EN 16170; ČSN EN ISO 54321)
34 Drinking water, raw water (surface, ground), service water, waste water, aqueous extract of sludge, sediment, screenings, sand, soil, sludge, sediment, screenings, sand, soil Determination of mercury by spectrophotometry (Hg)
Mercury (Hg)
Regulated area: Waste Water Laboratory – Tests
by spectrophotometry SOP-O-76/Hg (ČSN 75 7440; EPA Method 7473; ČSN EN 16173)
35 Drinking water, raw water (surface, ground), service water, waste water, aqueous extract of sludge, sediment, screenings, sand, soil Determination of total nitrogen using a TN analyser (N tot.)
Regulated area: Waste Water Laboratory – Tests
TN analyser SOP-O-67/C, 25/N cel. část A (ČSN EN ISO 20236)
36 Sludge, sediment, screenings, sand, soil Determination of total nitrogen using a TN analyser (N tot.)
Regulated area: Waste Water Laboratory – Tests
TN analyser SOP-O-67/C, 25/N cel. Část B (ČSN EN ISO 20236)
37 Drinking water, raw water (surface, ground), service water, waste water, aqueous extract of sludge, sediment, screenings, sand, soil Determination of total and inorganic carbon using a TC analyser (TC, TIC), organic carbon and dissolved organic carbon by calculation from measured values (TOC, DOC)
organic carbon, dissolved organic carbon by calculation from measured values (TOC, DOC) (calculated)
Regulated area: Waste Water Laboratory – Tests
TC analyser SOP-O-67/C, 25/N cel. (ČSN EN 1484; ČSN EN ISO 20236)
38 Drinking water, raw water (surface, ground), service water Determination of metals by ICP/MS method and hardness by calculation from measured values
Silver (Ag) Aluminium (Al) Arsenic (As) Boron (B) Barium (Ba) Beryllium (Be) Calcium (Ca) Cadmium (Cd) Cobalt (Co) Chromium (Cr) Copper (Cu) Iron (Fe) Potassium (K) Magnesium (Mg) Manganese (Mn) Molybdenum (Mo) Sodium (Na) Nickel (Ni) Phosphorus (P) Lead (Pb) Antimony (Sb) Selenium (Se) Silicon (Si) Strontium (Sr) Tin (Sn) Vanadium (V) Zinc (Zn)
hardness by calculation from measured values (calculated)
Regulated area: Waste Water Laboratory – Tests
ICP/MS method SOP-O-84/kovy ICP MS-74/kovy část A (ČSN EN ISO 17294-1; ČSN EN ISO 17294-2)
39 Waste water, aqueous extract of sludge, sediment, screenings, sand, soil Determination of metals by ICP/MS method
Silver (Ag) Aluminium (Al) Arsenic (As) Boron (B) Barium (Ba) Beryllium (Be) Calcium (Ca) Cadmium (Cd) Cobalt (Co) Chromium (Cr) Copper (Cu) Iron (Fe) Potassium (K) Magnesium (Mg) Manganese (Mn) Molybdenum (Mo) Sodium (Na) Nickel (Ni) Phosphorus (P) Lead (Pb) Antimony (Sb) Selenium (Se) Tin (Sn) Vanadium (V) Zinc (Zn)
Regulated area: Waste Water Laboratory – Tests
ICP/MS method SOP-O-84/kovy ICP MS-74/kovy část B (ČSN EN ISO 17294-1; ČSN EN ISO 17294-2)
40 Sludge, sediment, screenings, sand, soil Determination of metals by ICP/MS method
Silver (Ag) Aluminium (Al) Arsenic (As) Barium (Ba) Beryllium (Be) Calcium (Ca) Cadmium (Cd) Cobalt (Co) Chromium (Cr) Copper (Cu) Iron (Fe) Potassium (K) Magnesium (Mg) Molybdenum (Mo) Nickel (Ni) Phosphorus (P) Lead (Pb) Selenium (Se) Vanadium (V) Zinc (Zn)
Regulated area: Waste Water Laboratory – Tests
ICP/MS method SOP-O-84/kovy ICP MS-74/kovy část C (ČSN EN ISO 17294-1; ČSN EN ISO 17294-2; ČSN EN 16173; ČSN EN 16171; ČSN EN ISO 54321)
41 Drinking water, raw water (surface, ground), service water, waste water Determination of hydrocarbons C10 – C40 by GC with flame ionisation detection
Regulated area: Waste Water Laboratory – Tests
GC with flame ionisation detection SOP-O-30/ C10 – C40 (ČSN EN ISO 9377-2; TNI 757507)
42 Drinking water, raw water (surface, ground), service water, waste water, aqueous extract of sludge, sediment, screenings, sand, soil Determination of analytes (PAL A, Cl-, SO42-, F-) by CFA method
Regulated area: Waste Water Laboratory – Tests
CFA method SOP-O-86/analyty CFA II (ČSN ISO 16265; ČSN EN ISO 15682; ČSN ISO 22743; TNV 75 7431)
43 Drinking water, raw water (surface, ground for drinking water production), service water Water sampling
Regulated area: Waste Water Laboratory – Sampling
SOP-500/odběr A (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN EN ISO 5667-16; ČSN ISO 5667-5; ČSN EN ISO 5667-14; ČSN EN ISO 19458; Vyhláška MZ č. 252/04 Sb.)
44 Waste water Sampling of waste water (manual and automatic sampler)
Regulated area: Waste Water Laboratory – Sampling
SOP-500/odběr B1 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-10; ČSN EN ISO 5667-14; ČSN 75 7315)
45 Sludge, sediment, screenings, sand, soil Sampling of sludge
Regulated area: Waste Water Laboratory – Sampling
SOP-500/odběr B2 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN EN ISO 5667-13; ČSN EN ISO 5667-14; ČSN EN ISO 5667-15)
Drinking Water Laboratory
46 Drinking water, raw water (surface, ground), service water Determination of colour by photometry
Regulated area: Drinking Water Laboratory – Tests
by photometry SOP-P-01/B (ČSN EN ISO 7887)
47 Drinking water, raw water (ground), service water Determination of odour by sensory method
Regulated area: Drinking Water Laboratory – Tests
sensory method SOP-P-02/pach (ČSN 757340; ČSN EN 1622)
48 Drinking water Determination of taste by sensory method
Regulated area: Drinking Water Laboratory – Tests
sensory method SOP-P-79/chuť (ČSN 757340; ČSN EN 1622)
49 Drinking water, raw water (surface, ground), service water Determination of conductivity by conductometry
Regulated area: Drinking Water Laboratory – Tests
conductometry SOP-P-04/KON (ČSN EN 27888)
50 Drinking water, raw water (surface, ground), service water Determination of turbidity by nephelometry
Regulated area: Drinking Water Laboratory – Tests
nephelometry SOP-P-06/Z (ČSN EN ISO 7027-1)
51 Drinking water, raw water (surface, ground), service water Determination of pH by potentiometry
Regulated area: Drinking Water Laboratory – Tests
by potentiometry SOP-P-07/pH (ČSN ISO 10523)
52 Drinking water, raw water (surface, ground), service water Determination of acid neutralizing capacity by titration (ANC4.5)
Regulated area: Drinking Water Laboratory – Tests
by titration SOP-P-KNK4.5 (ČSN ISO 9963-1)
53 Drinking water, raw water (surface, ground), service water Determination of chemical oxygen demand by permanganate by titration (CODMn)
Regulated area: Drinking Water Laboratory – Tests
by titration SOP-P-12/CHSKMn (ČSN EN ISO 8467)
54 Drinking water, raw water (surface, ground), service water Determination of suspended solids by gravimetry (SS)
Regulated area: Drinking Water Laboratory – Tests
by gravimetry SOP-P-16/NL (ČSN EN 872)
55 Drinking water, raw water (surface, ground), service water Determination of dissolved solids by gravimetry (DS)
Regulated area: Drinking Water Laboratory – Tests
by gravimetry SOP-P-18/RL (ČSN 75 7346)
56 Drinking water, raw water (surface, ground), service water Determination of ammonium ions by photometry (NH4+), ammonia nitrogen (N-NH4+) by calculation from measured values
ammonia nitrogen (N-NH4+) by calculation from measured values (calculated)
Regulated area: Drinking Water Laboratory – Tests
by photometry SOP-P-21/NH4+ (ČSN ISO 7150-1)
57 Drinking water, raw water (surface, ground), service water Determination of nitrite by photometry (NO2-), nitrite nitrogen (N-NO2-) by calculation from measured values
nitrite nitrogen (N-NO2-) by calculation from measured values (calculated)
Regulated area: Drinking Water Laboratory – Tests
by photometry SOP-P-22/NO2- (ČSN EN 26777)
58 Drinking water, raw water (surface, ground), service water Determination of volatile organic compounds by GC/MS method (VOC)
Regulated area: Drinking Water Laboratory – Tests
GC/MS method SOP-P-69/analyty GC MS - 65/TOL (ČSN EN ISO 10301; ČSN EN ISO 17943)
59 Drinking water, raw water (surface, ground), service water Determination of pesticides, their metabolites and other organic substances by LC/MS/MS method, total pesticides by calculation from measured values (PLC)
total pesticides by calculation from measured values (PLC) (calculated)
Regulated area: Drinking Water Laboratory – Tests
LC/MS/MS method SOP-P-90/analyty LC MS, LC – PST ESI+ , 68/PLC (EPA Method 547; EPA Method 1694; EPA Method 535-1; EPA Method 536-1; EPA Method 537-1)
60 Drinking water, raw water (surface, ground), service water Determination of pesticides and other organic substances by LC/MS/MS method
Regulated area: Drinking Water Laboratory – Tests
LC/MS/MS method SOP-P-90/analyty LC MS, LC – PST ESI- , 68/PLC (EPA Method 547; EPA Method 1694; EPA Method 535-1; EPA Method 536-1; EPA Method 537-1)
61 Drinking water, raw water (surface, ground), service water, waste water, aqueous extract of sludge, sediment, screenings, sand, soil Determination of total organic carbon and dissolved organic carbon using a TOC analyser (TOC, DOC)
Regulated area: Drinking Water Laboratory – Tests
TOC analyser SOP-P-67/C (ČSN EN 1484; ČSN EN ISO 20236)
62 Drinking water, raw water (surface, ground), service water Determination of pesticides by GC/MS method (PST)
Regulated area: Drinking Water Laboratory – Tests
GC/MS method SOP-P-69/analyty GC MS - 69/PST (OCP) (ČSN EN ISO 10695; ČSN EN ISO 6468; ČSN ISO 27108)
63 Drinking water, raw water (surface, ground), service water, waste water, aqueous extract of sludge, sediment, screenings, sand, soil Determination of anions by IC method and nitrogen forms (N-NO2-, N-NO3-) by calculation from measured values
nitrogen forms (N-NO2-, N-NO3-) by calculation from measured values (calculated)
Regulated area: Drinking Water Laboratory – Tests
ion chromatography SOP-P-85/anionty IC (ČSN EN ISO 10304-1; ČSN EN ISO 10304-4; ČSN EN ISO 15061; ČSN 75 7415; EPA Method 335.2)
64 Drinking water, raw water (surface, ground), service water Enumeration of culturable microorganisms at 22 °C by direct plating on nutrient agar culture medium
Regulated area: Drinking Water Laboratory – Tests
direct plating on nutrient agar culture medium SOP-P-51/KM22 °C (ČSN EN ISO 6222)
65 Drinking water, raw water (surface, ground), service water Enumeration of coliform bacteria, Escherichia coli by membrane filtration
Regulated area: Drinking Water Laboratory – Tests
membrane filtration SOP-P-52/KB, EC (ČSN EN ISO 9308-1:2001)
66 Drinking water Enumeration of coliform bacteria, Escherichia coli by Colilert method
Regulated area: Drinking Water Laboratory – Tests
Colilert method SOP-P-52a/KB, EC (ČSN EN ISO 9308-2)
67 Drinking water, raw water (surface, ground), service water Determination of the number of organisms, living organisms by microscopy
Regulated area: Drinking Water Laboratory – Tests
by microscopy SOP-P-53/BR-PO, ŽO (ČSN 75 7712)
68 Drinking water, raw water (surface, ground), service water Determination of abioseston by microscopy
Regulated area: Drinking Water Laboratory – Tests
by microscopy SOP-P-54/abioseston (ČSN 75 7713)
69 Drinking water, raw water (surface, ground), service water Enumeration of thermotolerant bacteria, Escherichia coli by membrane filtration
Regulated area: Drinking Water Laboratory – Tests
membrane filtration SOP-P-55/FB, EC (ČSN 75 7835)
70 Drinking water, raw water (surface, ground), service water Enumeration of coliform bacteria by membrane filtration
Regulated area: Drinking Water Laboratory – Tests
membrane filtration SOP-P-56/KB (ČSN 75 7837)
71 Drinking water, raw water (surface, ground), service water Enumeration of intestinal enterococci by membrane filtration
Regulated area: Drinking Water Laboratory – Tests
membrane filtration SOP-P-57/E (ČSN EN ISO 7899-2)
72 Drinking water, raw water (surface, ground), service water Enumeration of culturable microorganisms at 36 °C by direct plating on nutrient agar culture medium
Regulated area: Drinking Water Laboratory – Tests
direct plating on nutrient agar culture medium SOP-P-62/KM36 °C (ČSN EN ISO 6222)
73 Drinking water, raw water (surface, ground), service and waste water Determination of temperature (t)
Regulated area: Drinking Water Laboratory – Tests
SOP-03/teplota část A (ČSN 75 7342)
74 Sludge Determination of temperature (t)
Regulated area: Drinking Water Laboratory – Tests
SOP-03/teplota část B (ČSN 75 7342)
75 Drinking water, raw water (surface, ground), service water Determination of free and total chlorine by spectrometry using a HACH kit (Cl2), combined chlorine by calculation from measured values
combined chlorine by calculation from measured values (calculated)
Regulated area: Drinking Water Laboratory – Tests
spectrometry using a HACH kit SOP-37/Cl2 (ČSN EN ISO 7393-2)
76 Drinking water with low background microflora Enumeration of coliform bacteria, Escherichia coli by membrane filtration
Regulated area: Drinking Water Laboratory – Tests
membrane filtration SOP-P-52b/KB, EC (ČSN EN ISO 9308-1)
77 Drinking water, raw water (surface, ground), service water Enumeration of Clostridium perfringens by membrane filtration
Regulated area: Drinking Water Laboratory – Tests
membrane filtration SOP-P-58a/CP (ČSN EN ISO 14189)
78 Drinking water, raw water (surface, ground), service water Determination of pharmaceuticals by LC/MS/MS method (LEC)
Regulated area: Drinking Water Laboratory – Tests
LC/MS/MS method SOP-P-90/analyty LC MS, LC - 91/LEC ESI+ (ČSN EN ISO 21676)
79 Drinking water, raw water (surface, ground), service water Determination of pharmaceuticals by LC/MS/MS method (LEC)
Regulated area: Drinking Water Laboratory – Tests
LC/MS/MS method SOP-P-90/analyty LC MS, LC - 91/LEC ESI- (ČSN EN ISO 21676)
80 Drinking water, raw surface water for drinking water production Water sampling
Regulated area: Drinking Water Laboratory – Sampling
SOP-500/odběr A (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN EN ISO 5667-16; ČSN ISO 5667-5; ČSN EN ISO 5667-14; ČSN EN ISO 19458; Vyhláška č. 252/2004 Sb.)

Reference standards (181)

EPA Method 1694
EPA Method 335.2
EPA Method 535-1
EPA Method 536-1
EPA Method 537-1
EPA Method 547
EPA Method 7473
M. Horáková, P. Lischke, A. Grunwald: „Chemické a fyzikální metody analýzy vod“, SNTL Praha, 1986, kap. 2.22.2
M. Horáková, P. Lischke, A. Grunwald: „Chemické a fyzikální metody analýzy vod“, SNTL Praha, 1986, kap. 2.41.2
M. Horáková, P. Lischke, A. Grunwald: „Chemické a fyzikální metody analýzy vod“, SNTL Praha, 1986, kap. 2.42.1
SOP-03/teplota část A
SOP-03/teplota část B
SOP-37/Cl2
SOP-500/odběr A
SOP-500/odběr B1
SOP-500/odběr B2
SOP-O-07/pH část A
SOP-O-07/pH část B
SOP-O-08/KNK4.5 část A
SOP-O-08/KNK4.5 část B
SOP-O-11/CHSKCr /SP část A
SOP-O-11/CHSKCr /SP část B
SOP-O-11/CHSKCr část A
SOP-O-11/CHSKCr část B
SOP-O-13/BSK5
SOP-O-14/VL, 15/VLž. část A
SOP-O-14/VL, 15/VLž. část B
SOP-O-16/NL, 17/NLž. část A
SOP-O-16/NL, 17/NLž. část B
SOP-O-18/RL, 19/RLž.
SOP-O-21a/N-NH4+ část A
SOP-O-21a/N-NH4+ část B
SOP-O-24, 25/N část A
SOP-O-24, 25/N část B
SOP-O-28/PAL A
SOP-O-29/EL
SOP-O-30/ C10 – C40
SOP-O-32/analyty HPLC-32/PAU
SOP-O-36/Cl-
SOP-O-39/FN
SOP-O-40/AOX část A
SOP-O-40/AOX část B
SOP-O-67/C, 25/N cel.
SOP-O-67/C, 25/N cel. Část B
SOP-O-67/C, 25/N cel. část A
SOP-O-74/kovy ICP AES - 74/kovy část A
SOP-O-74/kovy ICP AES - 74/kovy část B
SOP-O-74/kovy ICP AES - 74/kovy část C
SOP-O-74/kovy ICP AES - 74/kovy část D
SOP-O-74/kovy ICP AES - 74/kovy část E
SOP-O-74/kovy ICP AES - 74/kovy část F
SOP-O-76/Hg
SOP-O-84/kovy ICP MS-74/kovy část A
SOP-O-84/kovy ICP MS-74/kovy část B
SOP-O-84/kovy ICP MS-74/kovy část C
SOP-O-86/analyty CFA II
SOP-O-86/ionty CFA část A
SOP-O-86/ionty CFA část B
SOP-P-01/B
SOP-P-02/pach
SOP-P-04/KON
SOP-P-06/Z
SOP-P-07/pH
SOP-P-12/CHSKMn
SOP-P-16/NL
SOP-P-18/RL
SOP-P-21/NH4+
SOP-P-22/NO2-
SOP-P-51/KM22 °C
SOP-P-52/KB, EC
SOP-P-52a/KB, EC
SOP-P-52b/KB, EC
SOP-P-53/BR-PO, ŽO
SOP-P-54/abioseston
SOP-P-55/FB, EC
SOP-P-56/KB
SOP-P-57/E
SOP-P-58a/CP
SOP-P-62/KM36 °C
SOP-P-67/C
SOP-P-69/analyty GC MS - 65/TOL
SOP-P-69/analyty GC MS - 69/PST (OCP)
SOP-P-79/chuť
SOP-P-85/anionty IC
SOP-P-90/analyty LC MS, LC - 91/LEC ESI+
SOP-P-90/analyty LC MS, LC - 91/LEC ESI-
SOP-P-90/analyty LC MS, LC – PST ESI+ , 68/PLC
SOP-P-90/analyty LC MS, LC – PST ESI- , 68/PLC
SOP-P-KNK4.5
TNI 757507
TNV 75 7431
Vyhláška MZ č. 252/04 Sb.
Vyhláška č. 252/2004 Sb.
návod firmy Merck
ČSN 75 7315
ČSN 75 7342
ČSN 75 7346
ČSN 75 7347
ČSN 75 7350
ČSN 75 7415
ČSN 75 7440
ČSN 75 7508
ČSN 75 7509
ČSN 75 7712
ČSN 75 7713
ČSN 75 7835
ČSN 75 7837
ČSN 757340
ČSN 83 0540-10:1985
ČSN 83 0540-13:1985, část C
ČSN 83 0540-3:1979, část A
ČSN EN 12176:1999
ČSN EN 12880
ČSN EN 13342
ČSN EN 14671
ČSN EN 1484
ČSN EN 15934
ČSN EN 15935
ČSN EN 16166
ČSN EN 16169
ČSN EN 16170
ČSN EN 16171
ČSN EN 16173
ČSN EN 1622
ČSN EN 1899-2
ČSN EN 25663
ČSN EN 26777
ČSN EN 27888
ČSN EN 872
ČSN EN ISO 10301
ČSN EN ISO 10304-1
ČSN EN ISO 10304-4
ČSN EN ISO 10390
ČSN EN ISO 10695
ČSN EN ISO 11732
ČSN EN ISO 11885
ČSN EN ISO 13395
ČSN EN ISO 14189
ČSN EN ISO 15061
ČSN EN ISO 15681-2
ČSN EN ISO 15682
ČSN EN ISO 17294-1
ČSN EN ISO 17294-2
ČSN EN ISO 17943
ČSN EN ISO 17993
ČSN EN ISO 19458
ČSN EN ISO 20236
ČSN EN ISO 21676
ČSN EN ISO 54321
ČSN EN ISO 5667-1
ČSN EN ISO 5667-13
ČSN EN ISO 5667-14
ČSN EN ISO 5667-15
ČSN EN ISO 5667-16
ČSN EN ISO 5667-3
ČSN EN ISO 5815-1
ČSN EN ISO 6222
ČSN EN ISO 6468
ČSN EN ISO 7027-1
ČSN EN ISO 7393-2
ČSN EN ISO 7887
ČSN EN ISO 7899-2
ČSN EN ISO 8467
ČSN EN ISO 9308-1
ČSN EN ISO 9308-1:2001
ČSN EN ISO 9308-2
ČSN EN ISO 9377-2
ČSN EN ISO 9562
ČSN ISO 10523
ČSN ISO 11349
ČSN ISO 15705
ČSN ISO 16265
ČSN ISO 17289
ČSN ISO 22743
ČSN ISO 27108
ČSN ISO 5664
ČSN ISO 5667-10
ČSN ISO 5667-5
ČSN ISO 6060
ČSN ISO 7150-1
ČSN ISO 9963-1

The same scope as data (JSON): https://labcoda.pl/api/accreditation-scopes/labs/CZ/1202