{"lab":{"_id":"69ad52a4de79e566650fd2e2","accr_number":"1202","country":"CZ","accr_body":"ČIA","address":"Malostranská 143/2, Doudlevce, 326 00 Plzeň","categories":["water","environment","microbiology"],"city":"Plzeň","imported_at":"2026-03-08T10:42:44.590Z","methods_count":80,"name":"VODÁRNA PLZEŇ a.s.","parse_status":"parsed","parse_version":5,"pdf_files":["1202_385_2024_CS.pdf","1202_385_2024_EN.pdf"],"scope_summary":"Pobieranie próbek, badania fizykochemiczne i mikrobiologiczne wód pitnych, surowych powierzchniowych, surowych podziemnych, użytkowych, ścieków, wyciągów wodnych, osadów, osadów dennych, skratek, piasków i gruntów.","search_text":"vodárna plzeň a.s. malostranská 143/2, doudlevce, 326 00 plzeň 1202","status":"active","updated_at":"2026-03-08T14:52:09.058Z","valid_from":"","valid_until":"04-01-2027","website":"www.vodarna.cz","location":{"type":"Point","coordinates":[13.3736,49.7384]},"email_confidence":"high","email_mx":true,"email_source":"https://www.vodarna.cz","map_coord":[49.724288,13.394807],"map_geo":"nominatim-street","certificate_date":"13.08.2024","certificate_no":"385/2024","certificate_replaces":"","en_official":false,"fields_of_testing":[{"codes":"","pl":"Pobieranie próbek, badania fizykochemiczne i mikrobiologiczne wód pitnych, surowych powierzchniowych, surowych podziemnych, użytkowych, ścieków, wyciągów wodnych, osadów, osadów dennych, skratek, piasków i gruntów.","en":"Sampling, physico-chemical and microbiological testing of drinking, raw surface, raw ground, service, waste water, aqueous extracts, sludge, sediments, screenings, sands, and soils.","zh":"饮用水、原地表水、原地下水、杂用水、废水、水浸出液、污泥、沉积物、栅渣、砂和土壤的采样及理化和微生物检测。","cs":"Vzorkování, fyzikálně-chemické a mikrobiologické zkoušení pitných, surových povrchových, surových podzemních, užitkových, odpadních vod, vodných výluhů, kalů, sedimentů, shrabků, písků a zemin."}],"flexible_scope":true,"flexible_scope_url":"https://www.vodarna.cz/laboratorni-rozbory","has_en":true,"has_zh":true,"lab_division":"zakład Laboratoria","lab_division_cs":"provoz Laboratoře","lab_division_en":"Laboratories operation","lab_division_zh":"实验室运营部","lab_locations":[{"code":null,"name":"VODÁRNA PLZEŇ a.s.","street":"Malostranská 143/2, Doudlevce","postal_code":"326 00","city":"Plzeň","is_hq":true,"address":"Malostranská 143/2, Doudlevce, 326 00 Plzeň","site":"32600|malostranská143/2doudlevce"},{"code":null,"name":"Laboratorium ścieków","street":"Jateční 2581/40","postal_code":"301 00","city":"Plzeň","is_hq":false,"address":"Jateční 2581/40, 301 00 Plzeň","site":"30100|jateční2581/40"},{"code":null,"name":"Laboratorium wód pitnych","street":"Malostranská 143/2, Doudlevce","postal_code":"326 00","city":"Plzeň","is_hq":false,"address":"Malostranská 143/2, Doudlevce, 326 00 Plzeň","site":"32600|malostranská143/2doudlevce"}],"lab_locations_en":[{"code":null,"name":"VODÁRNA PLZEŇ a.s.","street":"Malostranská 143/2, Doudlevce","postal_code":"326 00","city":"Plzeň","is_hq":true,"address":"Malostranská 143/2, Doudlevce, 326 00 Plzeň","site":"32600|malostranská143/2doudlevce"},{"code":null,"name":"Waste Water Laboratory","street":"Jateční 2581/40","postal_code":"301 00","city":"Plzeň","is_hq":false,"address":"Jateční 2581/40, 301 00 Plzeň","site":"30100|jateční2581/40"},{"code":null,"name":"Drinking Water Laboratory","street":"Malostranská 143/2, Doudlevce","postal_code":"326 00","city":"Plzeň","is_hq":false,"address":"Malostranská 143/2, Doudlevce, 326 00 Plzeň","site":"32600|malostranská143/2doudlevce"}],"lab_locations_zh":[{"code":null,"name":"VODÁRNA PLZEŇ a.s.","street":"Malostranská 143/2, Doudlevce","postal_code":"326 00","city":"Plzeň","is_hq":true,"address":"Malostranská 143/2, Doudlevce, 326 00 Plzeň","site":"32600|malostranská143/2doudlevce"},{"code":null,"name":"废水实验室","street":"Jateční 2581/40","postal_code":"301 00","city":"Plzeň","is_hq":false,"address":"Jateční 2581/40, 301 00 Plzeň","site":"30100|jateční2581/40"},{"code":null,"name":"饮用水实验室","street":"Malostranská 143/2, Doudlevce","postal_code":"326 00","city":"Plzeň","is_hq":false,"address":"Malostranská 143/2, Doudlevce, 326 00 Plzeň","site":"32600|malostranská143/2doudlevce"}],"parse_date":"2026-09-28T12:00:00.000Z","parse_source":"reczna-analiza-labcoda-3","parsed_at":"2026-09-28T12:00:00.000Z","scope_legend":[{"abbr":"SOP","pl":"standardowa procedura operacyjna","en":"standard operating procedure","zh":"标准操作规程","cs":"standardní operační postup"},{"abbr":"AMA","pl":"jednofunkcyjny atomowy spektrometr absorpcyjny","en":"single-purpose atomic absorption spectrometer","zh":"专用原子吸收光谱仪","cs":"jednoúčelový atomový absorpční spektrometr"},{"abbr":"CFA","pl":"analizator przepływowy","en":"continuous flow analyser","zh":"流动分析仪","cs":"průtokový analyzátor"},{"abbr":"GC","pl":"chromatografia gazowa","en":"gas chromatography","zh":"气相色谱","cs":"plynová chromatografie"},{"abbr":"GC/MS","pl":"chromatografia gazowa z detekcją mas","en":"gas chromatography with mass detection","zh":"气相色谱-质谱检测","cs":"plynová chromatografie s hmotnostní detekcí"},{"abbr":"LC/MS","pl":"chromatografia cieczowa z detekcją mas","en":"liquid chromatography with mass detection","zh":"液相色谱-质谱检测","cs":"kapalinová chromatografie s hmotnostní detekcí"},{"abbr":"LC","pl":"chromatografia cieczowa","en":"liquid chromatography","zh":"液相色谱","cs":"kapalinová chromatografie"},{"abbr":"IC","pl":"chromatografia jonowa","en":"ion chromatography","zh":"离子色谱","cs":"iontová chromatografie"},{"abbr":"ICP/MS","pl":"atomowy spektrometr emisyjny z detekcją mas","en":"atomic emission spectrometer with mass detection","zh":"带质谱检测的原子发射光谱仪","cs":"atomový emisní spektrometr s hmotnostní detekcí"},{"abbr":"ICP/AES","pl":"atomowy spektrometr emisyjny z plazmą wzbudzaną indukcyjnie","en":"inductively coupled plasma atomic emission spectrometer","zh":"电感耦合等离子体原子发射光谱仪","cs":"atomový emisní spektrometr s indukčně vázaným plazmatem"},{"abbr":"EPA","pl":"Agencja Ochrony Środowiska USA (U. S. Environmental Protection Agency)","en":"U. S. Environmental Protection Agency","zh":"美国环境保护署","cs":"U. S. Environmental Protection Agency"},{"abbr":"TC","pl":"węgiel całkowity","en":"total carbon","zh":"总碳","cs":"celkový uhlík"},{"abbr":"TN","pl":"azot całkowity","en":"total nitrogen","zh":"总氮","cs":"celkový dusík"},{"abbr":"CD","pl":"detektor konduktometryczny","en":"conductivity detector","zh":"电导检测器","cs":"detektor vodivostní"},{"abbr":"VA","pl":"detektor woltamperometryczny","en":"voltammetric detector","zh":"伏安检测器","cs":"detektor voltamperometrický"},{"abbr":"ESI","pl":"jonizacja przez elektrorozpylanie","en":"electrospray ionisation","zh":"电喷雾电离","cs":"elektrosprejová ionizace"}],"scope_notes":[{"pl":"Laboratorium wydaje opinie i interpretacje wyników badań.","en":"The laboratory provides opinions and interpretations of test results.","zh":"实验室提供检测结果的意见和解释。","cs":"Laboratoř poskytuje stanoviska a interpretace výsledků zkoušek."},{"pl":"Laboratorium jest kompetentne do samodzielnego pobierania próbek.","en":"The laboratory is qualified to carry out standalone sampling.","zh":"实验室有能力独立开展采样。","cs":"Laboratoř je způsobilá provádět samostatné vzorkování."}],"source_lang":"cs","source_pdf_sha256":"c8879dede49139cae49ee39a56f8515a4ce0574917a721e358205801e27d2960","source_pdf_url":"https://www.cai.cz/OA/pdf/P385_2024_CS.pdf","source_pdf_url_en":null},"methods":[{"_id":"9c32a5cba8054d015eddaee5","lab_id":"69ad52a4de79e566650fd2e2","country":"CZ","accr_number":"1202","accr_body":"ČIA","row_label":"1","test_object":"Woda pitna, surowa (powierzchniowa, podziemna), użytkowa, ścieki, wyciąg wodny z osadu, osadu dennego, skratek, piasku, gruntu","test_object_en":"Drinking water, raw water (surface, ground), service water, waste water, aqueous extract of sludge, sediment, screenings, sand, soil","test_object_zh":"饮用水、原水（地表水、地下水）、杂用水、废水、污泥、沉积物、栅渣、砂和土壤的水浸出液","test_object_cs":"Voda pitná, surová (povrchová, podzemní), užitková, odpadní, vodný výluh kalu, sedimentu, shrabků, písku, zeminy","methodology":"Oznaczanie pH metodą potencjometryczną","methodology_en":"Determination of pH by potentiometry","methodology_zh":"电位法测定pH","methodology_cs":"Stanovení pH potenciometricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"metoda potencjometryczna","technique_en":"by potentiometry","technique_zh":"电位法","technique_cs":"potenciometricky","techniques":["metoda potencjometryczna"],"techniques_en":["by potentiometry"],"techniques_zh":["电位法"],"techniques_cs":["potenciometricky"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie pH metodą potencjometryczną\nmetoda potencjometryczna","reference":"SOP-O-07/pH část A (ČSN ISO 10523)","norm_bases":["SOP-O-07/pH část A","ČSN ISO 10523"],"lab_section":"Laboratorium ścieków","lab_section_en":"Waste Water Laboratory","lab_section_zh":"废水实验室","lab_section_cs":"Laboratoř odpadních vod","lab_address":"Jateční 2581/40, 301 00 Plzeň","regulatory_area":"Laboratorium ścieków – Badania","regulatory_area_en":"Waste Water Laboratory – Tests","regulatory_area_zh":"废水实验室 – 检测","regulatory_area_cs":"Laboratoř odpadních vod – Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Woda pitna, surowa (powierzchniowa, podziemna), użytkowa, ścieki, wyciąg wodny z osadu, osadu dennego, skratek, piasku, gruntu Oznaczanie pH metodą potencjometryczną metoda potencjometryczna Voda pitná, surová (povrchová, podzemní), užitková, odpadní, vodný výluh kalu, sedimentu, shrabků, písku, zeminy Stanovení pH potenciometricky potenciometricky SOP-O-07/pH část A (ČSN ISO 10523) Woda pitna, surowa (powierzchniowa, podziemna), uzytkowa, scieki, wyciag wodny z osadu, osadu dennego, skratek, piasku, gruntu Oznaczanie pH metoda potencjometryczna metoda potencjometryczna Voda pitna, surova (povrchova, podzemni), uzitkova, odpadni, vodny vyluh kalu, sedimentu, shrabku, pisku, zeminy Stanoveni pH potenciometricky potenciometricky SOP-O-07/pH cast A (CSN ISO 10523)","search_en":"Drinking water, raw water (surface, ground), service water, waste water, aqueous extract of sludge, sediment, screenings, sand, soil Determination of pH by potentiometry by potentiometry SOP-O-07/pH část A (ČSN ISO 10523)","search_zh":"饮用水、原水（地表水、地下水）、杂用水、废水、污泥、沉积物、栅渣、砂和土壤的水浸出液 电位法测定pH 电位法 SOP-O-07/pH část A (ČSN ISO 10523)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":0,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"0edd8020f114e3360d68a0ac","lab_id":"69ad52a4de79e566650fd2e2","country":"CZ","accr_number":"1202","accr_body":"ČIA","row_label":"2","test_object":"Osad, osad denny, skratki, piasek, grunt","test_object_en":"Sludge, sediment, screenings, sand, soil","test_object_zh":"污泥、沉积物、栅渣、砂、土壤","test_object_cs":"Kal, sediment, shrabky, písek, zemina","methodology":"Oznaczanie pH metodą potencjometryczną","methodology_en":"Determination of pH by potentiometry","methodology_zh":"电位法测定pH","methodology_cs":"Stanovení pH potenciometricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"metoda potencjometryczna","technique_en":"by potentiometry","technique_zh":"电位法","technique_cs":"potenciometricky","techniques":["metoda potencjometryczna"],"techniques_en":["by potentiometry"],"techniques_zh":["电位法"],"techniques_cs":["potenciometricky"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie pH metodą potencjometryczną\nmetoda potencjometryczna","reference":"SOP-O-07/pH část B (ČSN EN 12176:1999; ČSN EN ISO 10390)","norm_bases":["SOP-O-07/pH část B","ČSN EN 12176:1999","ČSN EN ISO 10390"],"lab_section":"Laboratorium ścieków","lab_section_en":"Waste Water Laboratory","lab_section_zh":"废水实验室","lab_section_cs":"Laboratoř odpadních vod","lab_address":"Jateční 2581/40, 301 00 Plzeň","regulatory_area":"Laboratorium ścieków – Badania","regulatory_area_en":"Waste Water Laboratory – Tests","regulatory_area_zh":"废水实验室 – 检测","regulatory_area_cs":"Laboratoř odpadních vod – Zkoušky","flexible":true,"flexibility":"A","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Osad, osad denny, skratki, piasek, grunt Oznaczanie pH metodą potencjometryczną metoda potencjometryczna Kal, sediment, shrabky, písek, zemina Stanovení pH potenciometricky potenciometricky SOP-O-07/pH část B (ČSN EN 12176:1999; ČSN EN ISO 10390) Osad, osad denny, skratki, piasek, grunt Oznaczanie pH metoda potencjometryczna metoda potencjometryczna Kal, sediment, shrabky, pisek, zemina Stanoveni pH potenciometricky potenciometricky SOP-O-07/pH cast B (CSN EN 12176:1999; CSN EN ISO 10390)","search_en":"Sludge, sediment, screenings, sand, soil Determination of pH by potentiometry by potentiometry SOP-O-07/pH část B (ČSN EN 12176:1999; ČSN EN ISO 10390)","search_zh":"污泥、沉积物、栅渣、砂、土壤 电位法测定pH 电位法 SOP-O-07/pH část B (ČSN EN 12176:1999; ČSN EN ISO 10390)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":1,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"98edbdf405a74ca16096b655","lab_id":"69ad52a4de79e566650fd2e2","country":"CZ","accr_number":"1202","accr_body":"ČIA","row_label":"3","test_object":"Woda pitna, surowa (powierzchniowa, podziemna), użytkowa, ścieki","test_object_en":"Drinking water, raw water (surface, ground), service water, waste water","test_object_zh":"饮用水、原水（地表水、地下水）、杂用水、废水","test_object_cs":"Voda pitná, surová (povrchová, podzemní), užitková, odpadní","methodology":"Oznaczanie kwasowej pojemności neutralizacyjnej metodą potencjometryczną (KNK4,5)","methodology_en":"Determination of acid neutralizing capacity by potentiometry (ANC4.5)","methodology_zh":"电位法测定酸中和能力（ANC4.5）","methodology_cs":"Stanovení kyselinové neutralizační kapacity potenciometricky (KNK4.5)","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"metoda potencjometryczna","technique_en":"by potentiometry","technique_zh":"电位法","technique_cs":"potenciometricky","techniques":["metoda potencjometryczna"],"techniques_en":["by potentiometry"],"techniques_zh":["电位法"],"techniques_cs":["potenciometricky"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie kwasowej pojemności neutralizacyjnej metodą potencjometryczną (KNK4,5)\nmetoda potencjometryczna","reference":"SOP-O-08/KNK4.5 část A (ČSN ISO 9963-1)","norm_bases":["SOP-O-08/KNK4.5 část A","ČSN ISO 9963-1"],"lab_section":"Laboratorium ścieków","lab_section_en":"Waste Water Laboratory","lab_section_zh":"废水实验室","lab_section_cs":"Laboratoř odpadních vod","lab_address":"Jateční 2581/40, 301 00 Plzeň","regulatory_area":"Laboratorium ścieków – Badania","regulatory_area_en":"Waste Water Laboratory – Tests","regulatory_area_zh":"废水实验室 – 检测","regulatory_area_cs":"Laboratoř odpadních vod – Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Woda pitna, surowa (powierzchniowa, podziemna), użytkowa, ścieki Oznaczanie kwasowej pojemności neutralizacyjnej metodą potencjometryczną (KNK4,5) metoda potencjometryczna Voda pitná, surová (povrchová, podzemní), užitková, odpadní Stanovení kyselinové neutralizační kapacity potenciometricky (KNK4.5) potenciometricky SOP-O-08/KNK4.5 část A (ČSN ISO 9963-1) Woda pitna, surowa (powierzchniowa, podziemna), uzytkowa, scieki Oznaczanie kwasowej pojemnosci neutralizacyjnej metoda potencjometryczna (KNK4,5) metoda potencjometryczna Voda pitna, surova (povrchova, podzemni), uzitkova, odpadni Stanoveni kyselinove neutralizacni kapacity potenciometricky (KNK4.5) potenciometricky SOP-O-08/KNK4.5 cast A (CSN ISO 9963-1)","search_en":"Drinking water, raw water (surface, ground), service water, waste water Determination of acid neutralizing capacity by potentiometry (ANC4.5) by potentiometry SOP-O-08/KNK4.5 část A (ČSN ISO 9963-1)","search_zh":"饮用水、原水（地表水、地下水）、杂用水、废水 电位法测定酸中和能力（ANC4.5） 电位法 SOP-O-08/KNK4.5 část A (ČSN ISO 9963-1)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":2,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"54e6e24d03f177b1d29f4521","lab_id":"69ad52a4de79e566650fd2e2","country":"CZ","accr_number":"1202","accr_body":"ČIA","row_label":"4","test_object":"Osad, osad denny, skratki, piasek, grunt","test_object_en":"Sludge, sediment, screenings, sand, soil","test_object_zh":"污泥、沉积物、栅渣、砂、土壤","test_object_cs":"Kal, sediment, shrabky, písek, zemina","methodology":"Oznaczanie kwasowej pojemności neutralizacyjnej metodą potencjometryczną (KNK4,5)","methodology_en":"Determination of acid neutralizing capacity by potentiometry (ANC4.5)","methodology_zh":"电位法测定酸中和能力（ANC4.5）","methodology_cs":"Stanovení kyselinové neutralizační kapacity potenciometricky (KNK4.5)","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"metoda potencjometryczna","technique_en":"by potentiometry","technique_zh":"电位法","technique_cs":"potenciometricky","techniques":["metoda potencjometryczna"],"techniques_en":["by potentiometry"],"techniques_zh":["电位法"],"techniques_cs":["potenciometricky"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie kwasowej pojemności neutralizacyjnej metodą potencjometryczną (KNK4,5)\nmetoda potencjometryczna","reference":"SOP-O-08/KNK4.5 část B (ČSN ISO 9963-1)","norm_bases":["SOP-O-08/KNK4.5 část B","ČSN ISO 9963-1"],"lab_section":"Laboratorium ścieków","lab_section_en":"Waste Water Laboratory","lab_section_zh":"废水实验室","lab_section_cs":"Laboratoř odpadních vod","lab_address":"Jateční 2581/40, 301 00 Plzeň","regulatory_area":"Laboratorium ścieków – Badania","regulatory_area_en":"Waste Water Laboratory – Tests","regulatory_area_zh":"废水实验室 – 检测","regulatory_area_cs":"Laboratoř odpadních vod – Zkoušky","flexible":true,"flexibility":"A","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Osad, osad denny, skratki, piasek, grunt Oznaczanie kwasowej pojemności neutralizacyjnej metodą potencjometryczną (KNK4,5) metoda potencjometryczna Kal, sediment, shrabky, písek, zemina Stanovení kyselinové neutralizační kapacity potenciometricky (KNK4.5) potenciometricky SOP-O-08/KNK4.5 část B (ČSN ISO 9963-1) Osad, osad denny, skratki, piasek, grunt Oznaczanie kwasowej pojemnosci neutralizacyjnej metoda potencjometryczna (KNK4,5) metoda potencjometryczna Kal, sediment, shrabky, pisek, zemina Stanoveni kyselinove neutralizacni kapacity potenciometricky (KNK4.5) potenciometricky SOP-O-08/KNK4.5 cast B (CSN ISO 9963-1)","search_en":"Sludge, sediment, screenings, sand, soil Determination of acid neutralizing capacity by potentiometry (ANC4.5) by potentiometry SOP-O-08/KNK4.5 část B (ČSN ISO 9963-1)","search_zh":"污泥、沉积物、栅渣、砂、土壤 电位法测定酸中和能力（ANC4.5） 电位法 SOP-O-08/KNK4.5 část B (ČSN ISO 9963-1)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":3,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"e6230d9e2498155c9b2cfa9d","lab_id":"69ad52a4de79e566650fd2e2","country":"CZ","accr_number":"1202","accr_body":"ČIA","row_label":"5","test_object":"Woda pitna, surowa (powierzchniowa, podziemna), użytkowa, ścieki, wyciąg wodny z osadu, osadu dennego, skratek, piasku, gruntu","test_object_en":"Drinking water, raw water (surface, ground), service water, waste water, aqueous extract of sludge, sediment, screenings, sand, soil","test_object_zh":"饮用水、原水（地表水、地下水）、杂用水、废水、污泥、沉积物、栅渣、砂和土壤的水浸出液","test_object_cs":"Voda pitná, surová (povrchová, podzemní), užitková, odpadní, vodný výluh kalu, sedimentu, shrabků, písku, zeminy","methodology":"Oznaczanie chemicznego zapotrzebowania tlenu metodą dwuchromianową, miareczkowo (ChZTCr)","methodology_en":"Determination of chemical oxygen demand by dichromate, titrimetric (CODCr)","methodology_zh":"重铬酸盐滴定法测定化学需氧量（CODCr）","methodology_cs":"Stanovení chemické spotřeby kyslíku dichromanem titračně (CHSKCr)","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"metoda miareczkowa","technique_en":"by titration","technique_zh":"滴定法","technique_cs":"titračně","techniques":["metoda miareczkowa"],"techniques_en":["by titration"],"techniques_zh":["滴定法"],"techniques_cs":["titračně"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie chemicznego zapotrzebowania tlenu metodą dwuchromianową, miareczkowo (ChZTCr)\nmetoda miareczkowa","reference":"SOP-O-11/CHSKCr část A (ČSN ISO 6060)","norm_bases":["SOP-O-11/CHSKCr část A","ČSN ISO 6060"],"lab_section":"Laboratorium ścieków","lab_section_en":"Waste Water Laboratory","lab_section_zh":"废水实验室","lab_section_cs":"Laboratoř odpadních vod","lab_address":"Jateční 2581/40, 301 00 Plzeň","regulatory_area":"Laboratorium ścieków – Badania","regulatory_area_en":"Waste Water Laboratory – Tests","regulatory_area_zh":"废水实验室 – 检测","regulatory_area_cs":"Laboratoř odpadních vod – Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Woda pitna, surowa (powierzchniowa, podziemna), użytkowa, ścieki, wyciąg wodny z osadu, osadu dennego, skratek, piasku, gruntu Oznaczanie chemicznego zapotrzebowania tlenu metodą dwuchromianową, miareczkowo (ChZTCr) metoda miareczkowa Voda pitná, surová (povrchová, podzemní), užitková, odpadní, vodný výluh kalu, sedimentu, shrabků, písku, zeminy Stanovení chemické spotřeby kyslíku dichromanem titračně (CHSKCr) titračně SOP-O-11/CHSKCr část A (ČSN ISO 6060) Woda pitna, surowa (powierzchniowa, podziemna), uzytkowa, scieki, wyciag wodny z osadu, osadu dennego, skratek, piasku, gruntu Oznaczanie chemicznego zapotrzebowania tlenu metoda dwuchromianowa, miareczkowo (ChZTCr) metoda miareczkowa Voda pitna, surova (povrchova, podzemni), uzitkova, odpadni, vodny vyluh kalu, sedimentu, shrabku, pisku, zeminy Stanoveni chemicke spotreby kysliku dichromanem titracne (CHSKCr) titracne SOP-O-11/CHSKCr cast A (CSN ISO 6060)","search_en":"Drinking water, raw water (surface, ground), service water, waste water, aqueous extract of sludge, sediment, screenings, sand, soil Determination of chemical oxygen demand by dichromate, titrimetric (CODCr) by titration SOP-O-11/CHSKCr část A (ČSN ISO 6060)","search_zh":"饮用水、原水（地表水、地下水）、杂用水、废水、污泥、沉积物、栅渣、砂和土壤的水浸出液 重铬酸盐滴定法测定化学需氧量（CODCr） 滴定法 SOP-O-11/CHSKCr část A (ČSN ISO 6060)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":4,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"af297253b1f7a24051a3e6fd","lab_id":"69ad52a4de79e566650fd2e2","country":"CZ","accr_number":"1202","accr_body":"ČIA","row_label":"6","test_object":"Osad","test_object_en":"Sludge","test_object_zh":"污泥","test_object_cs":"Kal","methodology":"Oznaczanie chemicznego zapotrzebowania tlenu metodą dwuchromianową, miareczkowo (ChZTCr)","methodology_en":"Determination of chemical oxygen demand by dichromate, titrimetric (CODCr)","methodology_zh":"重铬酸盐滴定法测定化学需氧量（CODCr）","methodology_cs":"Stanovení chemické spotřeby kyslíku dichromanem titračně (CHSKCr)","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"metoda miareczkowa","technique_en":"by titration","technique_zh":"滴定法","technique_cs":"titračně","techniques":["metoda miareczkowa"],"techniques_en":["by titration"],"techniques_zh":["滴定法"],"techniques_cs":["titračně"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie chemicznego zapotrzebowania tlenu metodą dwuchromianową, miareczkowo (ChZTCr)\nmetoda miareczkowa","reference":"SOP-O-11/CHSKCr část B (ČSN ISO 6060)","norm_bases":["SOP-O-11/CHSKCr část B","ČSN ISO 6060"],"lab_section":"Laboratorium ścieków","lab_section_en":"Waste Water Laboratory","lab_section_zh":"废水实验室","lab_section_cs":"Laboratoř odpadních vod","lab_address":"Jateční 2581/40, 301 00 Plzeň","regulatory_area":"Laboratorium ścieków – Badania","regulatory_area_en":"Waste Water Laboratory – Tests","regulatory_area_zh":"废水实验室 – 检测","regulatory_area_cs":"Laboratoř odpadních vod – Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Osad Oznaczanie chemicznego zapotrzebowania tlenu metodą dwuchromianową, miareczkowo (ChZTCr) metoda miareczkowa Kal Stanovení chemické spotřeby kyslíku dichromanem titračně (CHSKCr) titračně SOP-O-11/CHSKCr část B (ČSN ISO 6060) Osad Oznaczanie chemicznego zapotrzebowania tlenu metoda dwuchromianowa, miareczkowo (ChZTCr) metoda miareczkowa Kal Stanoveni chemicke spotreby kysliku dichromanem titracne (CHSKCr) titracne SOP-O-11/CHSKCr cast B (CSN ISO 6060)","search_en":"Sludge Determination of chemical oxygen demand by dichromate, titrimetric (CODCr) by titration SOP-O-11/CHSKCr část B (ČSN ISO 6060)","search_zh":"污泥 重铬酸盐滴定法测定化学需氧量（CODCr） 滴定法 SOP-O-11/CHSKCr část B (ČSN ISO 6060)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":5,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"53158024ea583abbd722533a","lab_id":"69ad52a4de79e566650fd2e2","country":"CZ","accr_number":"1202","accr_body":"ČIA","row_label":"7","test_object":"Woda pitna, surowa (powierzchniowa, podziemna), użytkowa, ścieki, wyciąg wodny z osadu, osadu dennego, skratek, piasku, gruntu","test_object_en":"Drinking water, raw water (surface, ground), service water, waste water, aqueous extract of sludge, sediment, screenings, sand, soil","test_object_zh":"饮用水、原水（地表水、地下水）、杂用水、废水、污泥、沉积物、栅渣、砂和土壤的水浸出液","test_object_cs":"Voda pitná, surová (povrchová, podzemní), užitková, odpadní, vodný výluh kalu, sedimentu, shrabků, písku, zeminy","methodology":"Oznaczanie chemicznego zapotrzebowania tlenu metodą dwuchromianową, spektrofotometrycznie – zestaw komercyjny Merck (ChZTCr)","methodology_en":"Determination of chemical oxygen demand by dichromate, spectrophotometric - Merck commercial kit (CODCr)","methodology_zh":"重铬酸盐分光光度法测定化学需氧量（CODCr）– Merck商品试剂盒","methodology_cs":"Stanovení chemické spotřeby kyslíku dichromanem spektrofotometricky - komerční souprava Merck (CHSKCr)","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"spektrofotometria – zestaw komercyjny Merck","technique_en":"spectrophotometry - Merck commercial kit","technique_zh":"分光光度法 – Merck商品试剂盒","technique_cs":"spektrofotometricky - komerční souprava Merck","techniques":["spektrofotometria – zestaw komercyjny Merck"],"techniques_en":["spectrophotometry - Merck commercial kit"],"techniques_zh":["分光光度法 – Merck商品试剂盒"],"techniques_cs":["spektrofotometricky - komerční souprava Merck"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie chemicznego zapotrzebowania tlenu metodą dwuchromianową, spektrofotometrycznie – zestaw komercyjny Merck (ChZTCr)\nspektrofotometria – zestaw komercyjny Merck","reference":"SOP-O-11/CHSKCr /SP část A (ČSN ISO 15705; návod firmy Merck)","norm_bases":["SOP-O-11/CHSKCr /SP část A","ČSN ISO 15705","návod firmy Merck"],"lab_section":"Laboratorium ścieków","lab_section_en":"Waste Water Laboratory","lab_section_zh":"废水实验室","lab_section_cs":"Laboratoř odpadních vod","lab_address":"Jateční 2581/40, 301 00 Plzeň","regulatory_area":"Laboratorium ścieków – Badania","regulatory_area_en":"Waste Water Laboratory – Tests","regulatory_area_zh":"废水实验室 – 检测","regulatory_area_cs":"Laboratoř odpadních vod – Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Woda pitna, surowa (powierzchniowa, podziemna), użytkowa, ścieki, wyciąg wodny z osadu, osadu dennego, skratek, piasku, gruntu Oznaczanie chemicznego zapotrzebowania tlenu metodą dwuchromianową, spektrofotometrycznie – zestaw komercyjny Merck (ChZTCr) spektrofotometria – zestaw komercyjny Merck Voda pitná, surová (povrchová, podzemní), užitková, odpadní, vodný výluh kalu, sedimentu, shrabků, písku, zeminy Stanovení chemické spotřeby kyslíku dichromanem spektrofotometricky - komerční souprava Merck (CHSKCr) spektrofotometricky - komerční souprava Merck SOP-O-11/CHSKCr /SP část A (ČSN ISO 15705; návod firmy Merck) Woda pitna, surowa (powierzchniowa, podziemna), uzytkowa, scieki, wyciag wodny z osadu, osadu dennego, skratek, piasku, gruntu Oznaczanie chemicznego zapotrzebowania tlenu metoda dwuchromianowa, spektrofotometrycznie – zestaw komercyjny Merck (ChZTCr) spektrofotometria – zestaw komercyjny Merck Voda pitna, surova (povrchova, podzemni), uzitkova, odpadni, vodny vyluh kalu, sedimentu, shrabku, pisku, zeminy Stanoveni chemicke spotreby kysliku dichromanem spektrofotometricky - komercni souprava Merck (CHSKCr) spektrofotometricky - komercni souprava Merck SOP-O-11/CHSKCr /SP cast A (CSN ISO 15705; navod firmy Merck)","search_en":"Drinking water, raw water (surface, ground), service water, waste water, aqueous extract of sludge, sediment, screenings, sand, soil Determination of chemical oxygen demand by dichromate, spectrophotometric - Merck commercial kit (CODCr) spectrophotometry - Merck commercial kit SOP-O-11/CHSKCr /SP část A (ČSN ISO 15705; návod firmy Merck)","search_zh":"饮用水、原水（地表水、地下水）、杂用水、废水、污泥、沉积物、栅渣、砂和土壤的水浸出液 重铬酸盐分光光度法测定化学需氧量（CODCr）– Merck商品试剂盒 分光光度法 – Merck商品试剂盒 SOP-O-11/CHSKCr /SP část A (ČSN ISO 15705; návod firmy Merck)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":6,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"3459fd63fbfcccfdcdc29081","lab_id":"69ad52a4de79e566650fd2e2","country":"CZ","accr_number":"1202","accr_body":"ČIA","row_label":"8","test_object":"Osad","test_object_en":"Sludge","test_object_zh":"污泥","test_object_cs":"Kal","methodology":"Oznaczanie chemicznego zapotrzebowania tlenu metodą dwuchromianową, spektrofotometrycznie – zestaw komercyjny Merck (ChZTCr)","methodology_en":"Determination of chemical oxygen demand by dichromate, spectrophotometric - Merck commercial kit (CODCr)","methodology_zh":"重铬酸盐分光光度法测定化学需氧量（CODCr）– Merck商品试剂盒","methodology_cs":"Stanovení chemické spotřeby kyslíku dichromanem spektrofotometricky - komerční souprava Merck (CHSKCr)","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"spektrofotometria – zestaw komercyjny Merck","technique_en":"spectrophotometry - Merck commercial kit","technique_zh":"分光光度法 – Merck商品试剂盒","technique_cs":"spektrofotometricky - komerční souprava Merck","techniques":["spektrofotometria – zestaw komercyjny Merck"],"techniques_en":["spectrophotometry - Merck commercial kit"],"techniques_zh":["分光光度法 – Merck商品试剂盒"],"techniques_cs":["spektrofotometricky - komerční souprava Merck"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie chemicznego zapotrzebowania tlenu metodą dwuchromianową, spektrofotometrycznie – zestaw komercyjny Merck (ChZTCr)\nspektrofotometria – zestaw komercyjny Merck","reference":"SOP-O-11/CHSKCr /SP část B (ČSN ISO 15705; návod firmy Merck)","norm_bases":["SOP-O-11/CHSKCr /SP část B","ČSN ISO 15705","návod firmy Merck"],"lab_section":"Laboratorium ścieków","lab_section_en":"Waste Water Laboratory","lab_section_zh":"废水实验室","lab_section_cs":"Laboratoř odpadních vod","lab_address":"Jateční 2581/40, 301 00 Plzeň","regulatory_area":"Laboratorium ścieków – Badania","regulatory_area_en":"Waste Water Laboratory – Tests","regulatory_area_zh":"废水实验室 – 检测","regulatory_area_cs":"Laboratoř odpadních vod – Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Osad Oznaczanie chemicznego zapotrzebowania tlenu metodą dwuchromianową, spektrofotometrycznie – zestaw komercyjny Merck (ChZTCr) spektrofotometria – zestaw komercyjny Merck Kal Stanovení chemické spotřeby kyslíku dichromanem spektrofotometricky - komerční souprava Merck (CHSKCr) spektrofotometricky - komerční souprava Merck SOP-O-11/CHSKCr /SP část B (ČSN ISO 15705; návod firmy Merck) Osad Oznaczanie chemicznego zapotrzebowania tlenu metoda dwuchromianowa, spektrofotometrycznie – zestaw komercyjny Merck (ChZTCr) spektrofotometria – zestaw komercyjny Merck Kal Stanoveni chemicke spotreby kysliku dichromanem spektrofotometricky - komercni souprava Merck (CHSKCr) spektrofotometricky - komercni souprava Merck SOP-O-11/CHSKCr /SP cast B (CSN ISO 15705; navod firmy Merck)","search_en":"Sludge Determination of chemical oxygen demand by dichromate, spectrophotometric - Merck commercial kit (CODCr) spectrophotometry - Merck commercial kit SOP-O-11/CHSKCr /SP část B (ČSN ISO 15705; návod firmy Merck)","search_zh":"污泥 重铬酸盐分光光度法测定化学需氧量（CODCr）– Merck商品试剂盒 分光光度法 – Merck商品试剂盒 SOP-O-11/CHSKCr /SP část B (ČSN ISO 15705; návod firmy Merck)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":7,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"5a5dd077d54a25e3583e81b4","lab_id":"69ad52a4de79e566650fd2e2","country":"CZ","accr_number":"1202","accr_body":"ČIA","row_label":"9","test_object":"Woda surowa (powierzchniowa, podziemna), użytkowa, ścieki, wyciąg wodny z osadu, osadu dennego, skratek, piasku, gruntu","test_object_en":"Raw water (surface, ground), service water, waste water, aqueous extract of sludge, sediment, screenings, sand, soil","test_object_zh":"原水（地表水、地下水）、杂用水、废水、污泥、沉积物、栅渣、砂和土壤的水浸出液","test_object_cs":"Voda surová (povrchová, podzemní), užitková, odpadní, vodný výluh kalu, sedimentu, shrabků, písku, zeminy","methodology":"Oznaczanie biochemicznego zapotrzebowania tlenu po n dniach metodą czujnika optycznego (BZTn)","methodology_en":"Determination of biochemical oxygen demand after n days by optical sensor method (BODn)","methodology_zh":"光学传感器法测定n日生化需氧量（BODn）","methodology_cs":"Stanovení biochemické spotřeby kyslíku po n dnech metodou optického senzoru (BSKn)","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"metoda z czujnikiem optycznym","technique_en":"optical sensor method","technique_zh":"光学传感器法","technique_cs":"metodou optického senzoru","techniques":["metoda z czujnikiem optycznym"],"techniques_en":["optical sensor method"],"techniques_zh":["光学传感器法"],"techniques_cs":["metodou optického senzoru"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie biochemicznego zapotrzebowania tlenu po n dniach metodą czujnika optycznego (BZTn)\nmetoda z czujnikiem optycznym","reference":"SOP-O-13/BSK5 (ČSN EN ISO 5815-1; ČSN EN 1899-2; ČSN ISO 17289)","norm_bases":["SOP-O-13/BSK5","ČSN EN ISO 5815-1","ČSN EN 1899-2","ČSN ISO 17289"],"lab_section":"Laboratorium ścieków","lab_section_en":"Waste Water Laboratory","lab_section_zh":"废水实验室","lab_section_cs":"Laboratoř odpadních vod","lab_address":"Jateční 2581/40, 301 00 Plzeň","regulatory_area":"Laboratorium ścieków – Badania","regulatory_area_en":"Waste Water Laboratory – Tests","regulatory_area_zh":"废水实验室 – 检测","regulatory_area_cs":"Laboratoř odpadních vod – Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Woda surowa (powierzchniowa, podziemna), użytkowa, ścieki, wyciąg wodny z osadu, osadu dennego, skratek, piasku, gruntu Oznaczanie biochemicznego zapotrzebowania tlenu po n dniach metodą czujnika optycznego (BZTn) metoda z czujnikiem optycznym Voda surová (povrchová, podzemní), užitková, odpadní, vodný výluh kalu, sedimentu, shrabků, písku, zeminy Stanovení biochemické spotřeby kyslíku po n dnech metodou optického senzoru (BSKn) metodou optického senzoru SOP-O-13/BSK5 (ČSN EN ISO 5815-1; ČSN EN 1899-2; ČSN ISO 17289) Woda surowa (powierzchniowa, podziemna), uzytkowa, scieki, wyciag wodny z osadu, osadu dennego, skratek, piasku, gruntu Oznaczanie biochemicznego zapotrzebowania tlenu po n dniach metoda czujnika optycznego (BZTn) metoda z czujnikiem optycznym Voda surova (povrchova, podzemni), uzitkova, odpadni, vodny vyluh kalu, sedimentu, shrabku, pisku, zeminy Stanoveni biochemicke spotreby kysliku po n dnech metodou optickeho senzoru (BSKn) metodou optickeho senzoru SOP-O-13/BSK5 (CSN EN ISO 5815-1; CSN EN 1899-2; CSN ISO 17289)","search_en":"Raw water (surface, ground), service water, waste water, aqueous extract of sludge, sediment, screenings, sand, soil Determination of biochemical oxygen demand after n days by optical sensor method (BODn) optical sensor method SOP-O-13/BSK5 (ČSN EN ISO 5815-1; ČSN EN 1899-2; ČSN ISO 17289)","search_zh":"原水（地表水、地下水）、杂用水、废水、污泥、沉积物、栅渣、砂和土壤的水浸出液 光学传感器法测定n日生化需氧量（BODn） 光学传感器法 SOP-O-13/BSK5 (ČSN EN ISO 5815-1; ČSN EN 1899-2; ČSN ISO 17289)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":8,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"73a74898f4b8504e7084deec","lab_id":"69ad52a4de79e566650fd2e2","country":"CZ","accr_number":"1202","accr_body":"ČIA","row_label":"10","test_object":"Woda pitna, surowa (powierzchniowa, podziemna), użytkowa, ścieki","test_object_en":"Drinking water, raw water (surface, ground), service water, waste water","test_object_zh":"饮用水、原水（地表水、地下水）、杂用水、废水","test_object_cs":"Voda pitná, surová (povrchová, podzemní), užitková, odpadní","methodology":"Oznaczanie substancji ogólnych, substancji ogólnych po prażeniu metodą wagową (VL, VLž.) oraz straty prażenia obliczeniowo z wartości zmierzonych (VLz.ž.)","methodology_en":"Determination of total solids, ignited total solids by gravimetry (TS, TSi) and loss on ignition by calculation from measured values (LOI)","methodology_zh":"重量法测定总固体、灼烧后总固体（TS、TSi），并由测量值计算灼烧减量","methodology_cs":"Stanovení veškerých látek, veškerých látek žíhaných gravimetricky (VL, VLž.) a ztráty žíháním výpočtem z naměřených hodnot (VLz.ž.)","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"metoda wagowa","technique_en":"by gravimetry","technique_zh":"重量法","technique_cs":"gravimetricky","techniques":["metoda wagowa"],"techniques_en":["by gravimetry"],"techniques_zh":["重量法"],"techniques_cs":["gravimetricky"],"computed":["strata prażenia (VLz.ž.) (obliczeniowo z wartości zmierzonych)"],"computed_en":["loss on ignition by calculation from measured values"],"computed_zh":["灼烧减量（由测量值计算）"],"computed_cs":["ztráty žíháním výpočtem z naměřených hodnot (VLz.ž.)"],"activity":"Oznaczanie substancji ogólnych, substancji ogólnych po prażeniu metodą wagową (VL, VLž.) oraz straty prażenia obliczeniowo z wartości zmierzonych (VLz.ž.)\nmetoda wagowa","reference":"SOP-O-14/VL, 15/VLž. část A (ČSN 83 0540-3:1979, část A)","norm_bases":["SOP-O-14/VL, 15/VLž. část A","ČSN 83 0540-3:1979, část A"],"lab_section":"Laboratorium ścieków","lab_section_en":"Waste Water Laboratory","lab_section_zh":"废水实验室","lab_section_cs":"Laboratoř odpadních vod","lab_address":"Jateční 2581/40, 301 00 Plzeň","regulatory_area":"Laboratorium ścieków – Badania","regulatory_area_en":"Waste Water Laboratory – Tests","regulatory_area_zh":"废水实验室 – 检测","regulatory_area_cs":"Laboratoř odpadních vod – Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Woda pitna, surowa (powierzchniowa, podziemna), użytkowa, ścieki Oznaczanie substancji ogólnych, substancji ogólnych po prażeniu metodą wagową (VL, VLž.) oraz straty prażenia obliczeniowo z wartości zmierzonych (VLz.ž.) metoda wagowa strata prażenia (VLz.ž.) (obliczeniowo z wartości zmierzonych) Voda pitná, surová (povrchová, podzemní), užitková, odpadní Stanovení veškerých látek, veškerých látek žíhaných gravimetricky (VL, VLž.) a ztráty žíháním výpočtem z naměřených hodnot (VLz.ž.) gravimetricky ztráty žíháním výpočtem z naměřených hodnot (VLz.ž.) SOP-O-14/VL, 15/VLž. část A (ČSN 83 0540-3:1979, část A) Woda pitna, surowa (powierzchniowa, podziemna), uzytkowa, scieki Oznaczanie substancji ogolnych, substancji ogolnych po prazeniu metoda wagowa (VL, VLz.) oraz straty prazenia obliczeniowo z wartosci zmierzonych (VLz.z.) metoda wagowa strata prazenia (VLz.z.) (obliczeniowo z wartosci zmierzonych) Voda pitna, surova (povrchova, podzemni), uzitkova, odpadni Stanoveni veskerych latek, veskerych latek zihanych gravimetricky (VL, VLz.) a ztraty zihanim vypoctem z namerenych hodnot (VLz.z.) gravimetricky ztraty zihanim vypoctem z namerenych hodnot (VLz.z.) SOP-O-14/VL, 15/VLz. cast A (CSN 83 0540-3:1979, cast A)","search_en":"Drinking water, raw water (surface, ground), service water, waste water Determination of total solids, ignited total solids by gravimetry (TS, TSi) and loss on ignition by calculation from measured values (LOI) by gravimetry loss on ignition by calculation from measured values SOP-O-14/VL, 15/VLž. část A (ČSN 83 0540-3:1979, část A)","search_zh":"饮用水、原水（地表水、地下水）、杂用水、废水 重量法测定总固体、灼烧后总固体（TS、TSi），并由测量值计算灼烧减量 重量法 灼烧减量（由测量值计算） SOP-O-14/VL, 15/VLž. část A (ČSN 83 0540-3:1979, část A)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":9,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"c50ef6812aecf8fe06c0a88e","lab_id":"69ad52a4de79e566650fd2e2","country":"CZ","accr_number":"1202","accr_body":"ČIA","row_label":"11","test_object":"Osad, osad denny, skratki, piasek, grunt","test_object_en":"Sludge, sediment, screenings, sand, soil","test_object_zh":"污泥、沉积物、栅渣、砂、土壤","test_object_cs":"Kal, sediment, shrabky, písek, zemina","methodology":"Oznaczanie substancji ogólnych, substancji ogólnych po prażeniu metodą wagową (VL, VLž.) oraz straty prażenia obliczeniowo z wartości zmierzonych (VLz.ž.)","methodology_en":"Determination of total solids, ignited total solids by gravimetry (TS, TSi) and loss on ignition by calculation from measured values (LOI)","methodology_zh":"重量法测定总固体、灼烧后总固体（TS、TSi），并由测量值计算灼烧减量","methodology_cs":"Stanovení veškerých látek, veškerých látek žíhaných gravimetricky (VL, VLž.) a ztráty žíháním výpočtem z naměřených hodnot (VLz.ž.)","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"metoda wagowa","technique_en":"by gravimetry","technique_zh":"重量法","technique_cs":"gravimetricky","techniques":["metoda wagowa"],"techniques_en":["by gravimetry"],"techniques_zh":["重量法"],"techniques_cs":["gravimetricky"],"computed":["strata prażenia (VLz.ž.) (obliczeniowo z wartości zmierzonych)"],"computed_en":["loss on ignition by calculation from measured values"],"computed_zh":["灼烧减量（由测量值计算）"],"computed_cs":["ztráty žíháním výpočtem z naměřených hodnot (VLz.ž.)"],"activity":"Oznaczanie substancji ogólnych, substancji ogólnych po prażeniu metodą wagową (VL, VLž.) oraz straty prażenia obliczeniowo z wartości zmierzonych (VLz.ž.)\nmetoda wagowa","reference":"SOP-O-14/VL, 15/VLž. část B (ČSN EN 12880; ČSN EN 15934; ČSN EN 15935)","norm_bases":["SOP-O-14/VL, 15/VLž. část B","ČSN EN 12880","ČSN EN 15934","ČSN EN 15935"],"lab_section":"Laboratorium ścieków","lab_section_en":"Waste Water Laboratory","lab_section_zh":"废水实验室","lab_section_cs":"Laboratoř odpadních vod","lab_address":"Jateční 2581/40, 301 00 Plzeň","regulatory_area":"Laboratorium ścieków – Badania","regulatory_area_en":"Waste Water Laboratory – Tests","regulatory_area_zh":"废水实验室 – 检测","regulatory_area_cs":"Laboratoř odpadních vod – Zkoušky","flexible":true,"flexibility":"A","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Osad, osad denny, skratki, piasek, grunt Oznaczanie substancji ogólnych, substancji ogólnych po prażeniu metodą wagową (VL, VLž.) oraz straty prażenia obliczeniowo z wartości zmierzonych (VLz.ž.) metoda wagowa strata prażenia (VLz.ž.) (obliczeniowo z wartości zmierzonych) Kal, sediment, shrabky, písek, zemina Stanovení veškerých látek, veškerých látek žíhaných gravimetricky (VL, VLž.) a ztráty žíháním výpočtem z naměřených hodnot (VLz.ž.) gravimetricky ztráty žíháním výpočtem z naměřených hodnot (VLz.ž.) SOP-O-14/VL, 15/VLž. část B (ČSN EN 12880; ČSN EN 15934; ČSN EN 15935) Osad, osad denny, skratki, piasek, grunt Oznaczanie substancji ogolnych, substancji ogolnych po prazeniu metoda wagowa (VL, VLz.) oraz straty prazenia obliczeniowo z wartosci zmierzonych (VLz.z.) metoda wagowa strata prazenia (VLz.z.) (obliczeniowo z wartosci zmierzonych) Kal, sediment, shrabky, pisek, zemina Stanoveni veskerych latek, veskerych latek zihanych gravimetricky (VL, VLz.) a ztraty zihanim vypoctem z namerenych hodnot (VLz.z.) gravimetricky ztraty zihanim vypoctem z namerenych hodnot (VLz.z.) SOP-O-14/VL, 15/VLz. cast B (CSN EN 12880; CSN EN 15934; CSN EN 15935)","search_en":"Sludge, sediment, screenings, sand, soil Determination of total solids, ignited total solids by gravimetry (TS, TSi) and loss on ignition by calculation from measured values (LOI) by gravimetry loss on ignition by calculation from measured values SOP-O-14/VL, 15/VLž. část B (ČSN EN 12880; ČSN EN 15934; ČSN EN 15935)","search_zh":"污泥、沉积物、栅渣、砂、土壤 重量法测定总固体、灼烧后总固体（TS、TSi），并由测量值计算灼烧减量 重量法 灼烧减量（由测量值计算） SOP-O-14/VL, 15/VLž. část B (ČSN EN 12880; ČSN EN 15934; ČSN EN 15935)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":10,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"6e64f0b3279ebedb317fef0c","lab_id":"69ad52a4de79e566650fd2e2","country":"CZ","accr_number":"1202","accr_body":"ČIA","row_label":"12","test_object":"Woda pitna, surowa (powierzchniowa, podziemna), użytkowa, ścieki","test_object_en":"Drinking water, raw water (surface, ground), service water, waste water","test_object_zh":"饮用水、原水（地表水、地下水）、杂用水、废水","test_object_cs":"Voda pitná, surová (povrchová, podzemní), užitková, odpadní","methodology":"Oznaczanie zawiesin, zawiesin po prażeniu metodą wagową (NL, NLž.) oraz straty prażenia obliczeniowo z wartości zmierzonych (NLz.ž.)","methodology_en":"Determination of suspended solids, ignited suspended solids by gravimetry (SS, SSi) and loss on ignition by calculation from measured values","methodology_zh":"重量法测定悬浮物、灼烧后悬浮物，并由测量值计算灼烧减量","methodology_cs":"Stanovení nerozpuštěných látek, nerozpuštěných látek žíhaných gravimetricky (NL, NLž.) a ztráty žíháním výpočtem z naměřených hodnot (NLz.ž.)","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"metoda wagowa","technique_en":"by gravimetry","technique_zh":"重量法","technique_cs":"gravimetricky","techniques":["metoda wagowa"],"techniques_en":["by gravimetry"],"techniques_zh":["重量法"],"techniques_cs":["gravimetricky"],"computed":["strata prażenia (NLz.ž.) (obliczeniowo z wartości zmierzonych)"],"computed_en":["loss on ignition by calculation from measured values"],"computed_zh":["灼烧减量（由测量值计算）"],"computed_cs":["ztráty žíháním výpočtem z naměřených hodnot (NLz.ž.)"],"activity":"Oznaczanie zawiesin, zawiesin po prażeniu metodą wagową (NL, NLž.) oraz straty prażenia obliczeniowo z wartości zmierzonych (NLz.ž.)\nmetoda wagowa","reference":"SOP-O-16/NL, 17/NLž. část A (ČSN EN 872; ČSN 75 7350)","norm_bases":["SOP-O-16/NL, 17/NLž. část A","ČSN EN 872","ČSN 75 7350"],"lab_section":"Laboratorium ścieków","lab_section_en":"Waste Water Laboratory","lab_section_zh":"废水实验室","lab_section_cs":"Laboratoř odpadních vod","lab_address":"Jateční 2581/40, 301 00 Plzeň","regulatory_area":"Laboratorium ścieków – Badania","regulatory_area_en":"Waste Water Laboratory – Tests","regulatory_area_zh":"废水实验室 – 检测","regulatory_area_cs":"Laboratoř odpadních vod – Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Woda pitna, surowa (powierzchniowa, podziemna), użytkowa, ścieki Oznaczanie zawiesin, zawiesin po prażeniu metodą wagową (NL, NLž.) oraz straty prażenia obliczeniowo z wartości zmierzonych (NLz.ž.) metoda wagowa strata prażenia (NLz.ž.) (obliczeniowo z wartości zmierzonych) Voda pitná, surová (povrchová, podzemní), užitková, odpadní Stanovení nerozpuštěných látek, nerozpuštěných látek žíhaných gravimetricky (NL, NLž.) a ztráty žíháním výpočtem z naměřených hodnot (NLz.ž.) gravimetricky ztráty žíháním výpočtem z naměřených hodnot (NLz.ž.) SOP-O-16/NL, 17/NLž. část A (ČSN EN 872; ČSN 75 7350) Woda pitna, surowa (powierzchniowa, podziemna), uzytkowa, scieki Oznaczanie zawiesin, zawiesin po prazeniu metoda wagowa (NL, NLz.) oraz straty prazenia obliczeniowo z wartosci zmierzonych (NLz.z.) metoda wagowa strata prazenia (NLz.z.) (obliczeniowo z wartosci zmierzonych) Voda pitna, surova (povrchova, podzemni), uzitkova, odpadni Stanoveni nerozpustenych latek, nerozpustenych latek zihanych gravimetricky (NL, NLz.) a ztraty zihanim vypoctem z namerenych hodnot (NLz.z.) gravimetricky ztraty zihanim vypoctem z namerenych hodnot (NLz.z.) SOP-O-16/NL, 17/NLz. cast A (CSN EN 872; CSN 75 7350)","search_en":"Drinking water, raw water (surface, ground), service water, waste water Determination of suspended solids, ignited suspended solids by gravimetry (SS, SSi) and loss on ignition by calculation from measured values by gravimetry loss on ignition by calculation from measured values SOP-O-16/NL, 17/NLž. část A (ČSN EN 872; ČSN 75 7350)","search_zh":"饮用水、原水（地表水、地下水）、杂用水、废水 重量法测定悬浮物、灼烧后悬浮物，并由测量值计算灼烧减量 重量法 灼烧减量（由测量值计算） SOP-O-16/NL, 17/NLž. část A (ČSN EN 872; ČSN 75 7350)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":11,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"556a46b64c0bf82c4b8ad256","lab_id":"69ad52a4de79e566650fd2e2","country":"CZ","accr_number":"1202","accr_body":"ČIA","row_label":"13","test_object":"Osad, osad denny, skratki, piasek, grunt","test_object_en":"Sludge, sediment, screenings, sand, soil","test_object_zh":"污泥、沉积物、栅渣、砂、土壤","test_object_cs":"Kal, sediment, shrabky, písek, zemina","methodology":"Oznaczanie zawiesin, zawiesin po prażeniu metodą wagową (NL, NLž.) oraz straty prażenia obliczeniowo z wartości zmierzonych (NLz.ž.)","methodology_en":"Determination of suspended solids, ignited suspended solids by gravimetry (SS, SSi) and loss on ignition by calculation from measured values","methodology_zh":"重量法测定悬浮物、灼烧后悬浮物，并由测量值计算灼烧减量","methodology_cs":"Stanovení nerozpuštěných látek, nerozpuštěných látek žíhaných gravimetricky (NL, NLž.) a ztráty žíháním výpočtem z naměřených hodnot (NLz.ž.)","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"metoda wagowa","technique_en":"by gravimetry","technique_zh":"重量法","technique_cs":"gravimetricky","techniques":["metoda wagowa"],"techniques_en":["by gravimetry"],"techniques_zh":["重量法"],"techniques_cs":["gravimetricky"],"computed":["strata prażenia (NLz.ž.) (obliczeniowo z wartości zmierzonych)"],"computed_en":["loss on ignition by calculation from measured values"],"computed_zh":["灼烧减量（由测量值计算）"],"computed_cs":["ztráty žíháním výpočtem z naměřených hodnot (NLz.ž.)"],"activity":"Oznaczanie zawiesin, zawiesin po prażeniu metodą wagową (NL, NLž.) oraz straty prażenia obliczeniowo z wartości zmierzonych (NLz.ž.)\nmetoda wagowa","reference":"SOP-O-16/NL, 17/NLž. část B (ČSN EN 872; ČSN 75 7350)","norm_bases":["SOP-O-16/NL, 17/NLž. část B","ČSN EN 872","ČSN 75 7350"],"lab_section":"Laboratorium ścieków","lab_section_en":"Waste Water Laboratory","lab_section_zh":"废水实验室","lab_section_cs":"Laboratoř odpadních vod","lab_address":"Jateční 2581/40, 301 00 Plzeň","regulatory_area":"Laboratorium ścieków – Badania","regulatory_area_en":"Waste Water Laboratory – Tests","regulatory_area_zh":"废水实验室 – 检测","regulatory_area_cs":"Laboratoř odpadních vod – Zkoušky","flexible":true,"flexibility":"A","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Osad, osad denny, skratki, piasek, grunt Oznaczanie zawiesin, zawiesin po prażeniu metodą wagową (NL, NLž.) oraz straty prażenia obliczeniowo z wartości zmierzonych (NLz.ž.) metoda wagowa strata prażenia (NLz.ž.) (obliczeniowo z wartości zmierzonych) Kal, sediment, shrabky, písek, zemina Stanovení nerozpuštěných látek, nerozpuštěných látek žíhaných gravimetricky (NL, NLž.) a ztráty žíháním výpočtem z naměřených hodnot (NLz.ž.) gravimetricky ztráty žíháním výpočtem z naměřených hodnot (NLz.ž.) SOP-O-16/NL, 17/NLž. část B (ČSN EN 872; ČSN 75 7350) Osad, osad denny, skratki, piasek, grunt Oznaczanie zawiesin, zawiesin po prazeniu metoda wagowa (NL, NLz.) oraz straty prazenia obliczeniowo z wartosci zmierzonych (NLz.z.) metoda wagowa strata prazenia (NLz.z.) (obliczeniowo z wartosci zmierzonych) Kal, sediment, shrabky, pisek, zemina Stanoveni nerozpustenych latek, nerozpustenych latek zihanych gravimetricky (NL, NLz.) a ztraty zihanim vypoctem z namerenych hodnot (NLz.z.) gravimetricky ztraty zihanim vypoctem z namerenych hodnot (NLz.z.) SOP-O-16/NL, 17/NLz. cast B (CSN EN 872; CSN 75 7350)","search_en":"Sludge, sediment, screenings, sand, soil Determination of suspended solids, ignited suspended solids by gravimetry (SS, SSi) and loss on ignition by calculation from measured values by gravimetry loss on ignition by calculation from measured values SOP-O-16/NL, 17/NLž. část B (ČSN EN 872; ČSN 75 7350)","search_zh":"污泥、沉积物、栅渣、砂、土壤 重量法测定悬浮物、灼烧后悬浮物，并由测量值计算灼烧减量 重量法 灼烧减量（由测量值计算） SOP-O-16/NL, 17/NLž. část B (ČSN EN 872; ČSN 75 7350)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":12,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"5efc71d88f2e92a86946e520","lab_id":"69ad52a4de79e566650fd2e2","country":"CZ","accr_number":"1202","accr_body":"ČIA","row_label":"14","test_object":"Woda pitna, surowa (powierzchniowa, podziemna), użytkowa, ścieki, wyciąg wodny z osadu, osadu dennego, skratek, piasku, gruntu","test_object_en":"Drinking water, raw water (surface, ground), service water, waste water, aqueous extract of sludge, sediment, screenings, sand, soil","test_object_zh":"饮用水、原水（地表水、地下水）、杂用水、废水、污泥、沉积物、栅渣、砂和土壤的水浸出液","test_object_cs":"Voda pitná, surová (povrchová, podzemní), užitková, odpadní, vodný výluh kalu, sedimentu, shrabků, písku, zeminy","methodology":"Oznaczanie substancji rozpuszczonych, substancji rozpuszczonych po prażeniu metodą wagową i obliczeniowo z wartości zmierzonych (RL, RLž.) oraz straty prażenia obliczeniowo z wartości zmierzonych (RLz.ž.)","methodology_en":"Determination of dissolved solids, ignited dissolved solids by gravimetry and by calculation from measured values (DS, DSi) and loss on ignition by calculation from measured values","methodology_zh":"重量法及由测量值计算测定溶解性固体、灼烧后溶解性固体，并由测量值计算灼烧减量","methodology_cs":"Stanovení rozpuštěných látek, rozpuštěných látek žíhaných gravimetricky a výpočtem z naměřených hodnot (RL, RLž.) a ztráty žíháním výpočtem z naměřených hodnot (RLz.ž.)","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"metoda wagowa","technique_en":"by gravimetry","technique_zh":"重量法","technique_cs":"gravimetricky","techniques":["metoda wagowa"],"techniques_en":["by gravimetry"],"techniques_zh":["重量法"],"techniques_cs":["gravimetricky"],"computed":["strata prażenia (RLz.ž.) (obliczeniowo z wartości zmierzonych)"],"computed_en":["loss on ignition by calculation from measured values"],"computed_zh":["灼烧减量（由测量值计算）"],"computed_cs":["ztráty žíháním výpočtem z naměřených hodnot (RLz.ž.)"],"activity":"Oznaczanie substancji rozpuszczonych, substancji rozpuszczonych po prażeniu metodą wagową i obliczeniowo z wartości zmierzonych (RL, RLž.) oraz straty prażenia obliczeniowo z wartości zmierzonych (RLz.ž.)\nmetoda wagowa","reference":"SOP-O-18/RL, 19/RLž. (ČSN 75 7346; ČSN 75 7347)","norm_bases":["SOP-O-18/RL, 19/RLž.","ČSN 75 7346","ČSN 75 7347"],"lab_section":"Laboratorium ścieków","lab_section_en":"Waste Water Laboratory","lab_section_zh":"废水实验室","lab_section_cs":"Laboratoř odpadních vod","lab_address":"Jateční 2581/40, 301 00 Plzeň","regulatory_area":"Laboratorium ścieków – Badania","regulatory_area_en":"Waste Water Laboratory – Tests","regulatory_area_zh":"废水实验室 – 检测","regulatory_area_cs":"Laboratoř odpadních vod – Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Woda pitna, surowa (powierzchniowa, podziemna), użytkowa, ścieki, wyciąg wodny z osadu, osadu dennego, skratek, piasku, gruntu Oznaczanie substancji rozpuszczonych, substancji rozpuszczonych po prażeniu metodą wagową i obliczeniowo z wartości zmierzonych (RL, RLž.) oraz straty prażenia obliczeniowo z wartości zmierzonych (RLz.ž.) metoda wagowa strata prażenia (RLz.ž.) (obliczeniowo z wartości zmierzonych) Voda pitná, surová (povrchová, podzemní), užitková, odpadní, vodný výluh kalu, sedimentu, shrabků, písku, zeminy Stanovení rozpuštěných látek, rozpuštěných látek žíhaných gravimetricky a výpočtem z naměřených hodnot (RL, RLž.) a ztráty žíháním výpočtem z naměřených hodnot (RLz.ž.) gravimetricky ztráty žíháním výpočtem z naměřených hodnot (RLz.ž.) SOP-O-18/RL, 19/RLž. (ČSN 75 7346; ČSN 75 7347) Woda pitna, surowa (powierzchniowa, podziemna), uzytkowa, scieki, wyciag wodny z osadu, osadu dennego, skratek, piasku, gruntu Oznaczanie substancji rozpuszczonych, substancji rozpuszczonych po prazeniu metoda wagowa i obliczeniowo z wartosci zmierzonych (RL, RLz.) oraz straty prazenia obliczeniowo z wartosci zmierzonych (RLz.z.) metoda wagowa strata prazenia (RLz.z.) (obliczeniowo z wartosci zmierzonych) Voda pitna, surova (povrchova, podzemni), uzitkova, odpadni, vodny vyluh kalu, sedimentu, shrabku, pisku, zeminy Stanoveni rozpustenych latek, rozpustenych latek zihanych gravimetricky a vypoctem z namerenych hodnot (RL, RLz.) a ztraty zihanim vypoctem z namerenych hodnot (RLz.z.) gravimetricky ztraty zihanim vypoctem z namerenych hodnot (RLz.z.) SOP-O-18/RL, 19/RLz. (CSN 75 7346; CSN 75 7347)","search_en":"Drinking water, raw water (surface, ground), service water, waste water, aqueous extract of sludge, sediment, screenings, sand, soil Determination of dissolved solids, ignited dissolved solids by gravimetry and by calculation from measured values (DS, DSi) and loss on ignition by calculation from measured values by gravimetry loss on ignition by calculation from measured values SOP-O-18/RL, 19/RLž. (ČSN 75 7346; ČSN 75 7347)","search_zh":"饮用水、原水（地表水、地下水）、杂用水、废水、污泥、沉积物、栅渣、砂和土壤的水浸出液 重量法及由测量值计算测定溶解性固体、灼烧后溶解性固体，并由测量值计算灼烧减量 重量法 灼烧减量（由测量值计算） SOP-O-18/RL, 19/RLž. (ČSN 75 7346; ČSN 75 7347)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":13,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"65a7886d103fb5b9eeae4659","lab_id":"69ad52a4de79e566650fd2e2","country":"CZ","accr_number":"1202","accr_body":"ČIA","row_label":"15","test_object":"Woda pitna, surowa (powierzchniowa, podziemna), użytkowa, ścieki, wyciąg wodny z osadu, osadu dennego, skratek, piasku, gruntu","test_object_en":"Drinking water, raw water (surface, ground), service water, waste water, aqueous extract of sludge, sediment, screenings, sand, soil","test_object_zh":"饮用水、原水（地表水、地下水）、杂用水、废水、污泥、沉积物、栅渣、砂和土壤的水浸出液","test_object_cs":"Voda pitná, surová (povrchová, podzemní), užitková, odpadní, vodný výluh kalu, sedimentu, shrabků, písku, zeminy","methodology":"Oznaczanie jonów amonowych metodą destylacyjną (NH4+), azotu amonowego obliczeniowo z wartości zmierzonych (N-NH4+)","methodology_en":"Determination of ammonium ions by distillation (NH4+), ammonia nitrogen by calculation from measured values (N-NH4+)","methodology_zh":"蒸馏法测定铵离子（NH4+），并由测量值计算氨氮（N-NH4+）","methodology_cs":"Stanovení amonných iontů destilačně (NH4+), dusíku amoniakálního výpočtem z naměřených hodnot (N-NH4+)","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"metoda destylacyjna","technique_en":"by distillation","technique_zh":"蒸馏法","technique_cs":"destilačně","techniques":["metoda destylacyjna"],"techniques_en":["by distillation"],"techniques_zh":["蒸馏法"],"techniques_cs":["destilačně"],"computed":["azot amonowy (N-NH4+) (obliczeniowo z wartości zmierzonych)"],"computed_en":["ammonia nitrogen by calculation from measured values (N-NH4+)"],"computed_zh":["氨氮（N-NH4+）（由测量值计算）"],"computed_cs":["dusíku amoniakálního výpočtem z naměřených hodnot (N-NH4+)"],"activity":"Oznaczanie jonów amonowych metodą destylacyjną (NH4+), azotu amonowego obliczeniowo z wartości zmierzonych (N-NH4+)\nmetoda destylacyjna","reference":"SOP-O-21a/N-NH4+ část A (ČSN ISO 5664; ČSN 83 0540-10:1985)","norm_bases":["SOP-O-21a/N-NH4+ část A","ČSN ISO 5664","ČSN 83 0540-10:1985"],"lab_section":"Laboratorium ścieków","lab_section_en":"Waste Water Laboratory","lab_section_zh":"废水实验室","lab_section_cs":"Laboratoř odpadních vod","lab_address":"Jateční 2581/40, 301 00 Plzeň","regulatory_area":"Laboratorium ścieków – Badania","regulatory_area_en":"Waste Water Laboratory – Tests","regulatory_area_zh":"废水实验室 – 检测","regulatory_area_cs":"Laboratoř odpadních vod – Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Woda pitna, surowa (powierzchniowa, podziemna), użytkowa, ścieki, wyciąg wodny z osadu, osadu dennego, skratek, piasku, gruntu Oznaczanie jonów amonowych metodą destylacyjną (NH4+), azotu amonowego obliczeniowo z wartości zmierzonych (N-NH4+) metoda destylacyjna azot amonowy (N-NH4+) (obliczeniowo z wartości zmierzonych) Voda pitná, surová (povrchová, podzemní), užitková, odpadní, vodný výluh kalu, sedimentu, shrabků, písku, zeminy Stanovení amonných iontů destilačně (NH4+), dusíku amoniakálního výpočtem z naměřených hodnot (N-NH4+) destilačně dusíku amoniakálního výpočtem z naměřených hodnot (N-NH4+) SOP-O-21a/N-NH4+ část A (ČSN ISO 5664; ČSN 83 0540-10:1985) Woda pitna, surowa (powierzchniowa, podziemna), uzytkowa, scieki, wyciag wodny z osadu, osadu dennego, skratek, piasku, gruntu Oznaczanie jonow amonowych metoda destylacyjna (NH4+), azotu amonowego obliczeniowo z wartosci zmierzonych (N-NH4+) metoda destylacyjna azot amonowy (N-NH4+) (obliczeniowo z wartosci zmierzonych) Voda pitna, surova (povrchova, podzemni), uzitkova, odpadni, vodny vyluh kalu, sedimentu, shrabku, pisku, zeminy Stanoveni amonnych iontu destilacne (NH4+), dusiku amoniakalniho vypoctem z namerenych hodnot (N-NH4+) destilacne dusiku amoniakalniho vypoctem z namerenych hodnot (N-NH4+) SOP-O-21a/N-NH4+ cast A (CSN ISO 5664; CSN 83 0540-10:1985)","search_en":"Drinking water, raw water (surface, ground), service water, waste water, aqueous extract of sludge, sediment, screenings, sand, soil Determination of ammonium ions by distillation (NH4+), ammonia nitrogen by calculation from measured values (N-NH4+) by distillation ammonia nitrogen by calculation from measured values (N-NH4+) SOP-O-21a/N-NH4+ část A (ČSN ISO 5664; ČSN 83 0540-10:1985)","search_zh":"饮用水、原水（地表水、地下水）、杂用水、废水、污泥、沉积物、栅渣、砂和土壤的水浸出液 蒸馏法测定铵离子（NH4+），并由测量值计算氨氮（N-NH4+） 蒸馏法 氨氮（N-NH4+）（由测量值计算） SOP-O-21a/N-NH4+ část A (ČSN ISO 5664; ČSN 83 0540-10:1985)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":14,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"faea084d9645f7f4140bd3aa","lab_id":"69ad52a4de79e566650fd2e2","country":"CZ","accr_number":"1202","accr_body":"ČIA","row_label":"16","test_object":"Osad, osad denny, skratki, piasek, grunt","test_object_en":"Sludge, sediment, screenings, sand, soil","test_object_zh":"污泥、沉积物、栅渣、砂、土壤","test_object_cs":"Kal, sediment, shrabky, písek, zemina","methodology":"Oznaczanie jonów amonowych metodą destylacyjną (NH4+), azotu amonowego obliczeniowo z wartości zmierzonych (N-NH4+)","methodology_en":"Determination of ammonium ions by distillation (NH4+), ammonia nitrogen by calculation from measured values (N-NH4+)","methodology_zh":"蒸馏法测定铵离子（NH4+），并由测量值计算氨氮（N-NH4+）","methodology_cs":"Stanovení amonných iontů destilačně (NH4+), dusíku amoniakálního výpočtem z naměřených hodnot (N-NH4+)","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"metoda destylacyjna","technique_en":"by distillation","technique_zh":"蒸馏法","technique_cs":"destilačně","techniques":["metoda destylacyjna"],"techniques_en":["by distillation"],"techniques_zh":["蒸馏法"],"techniques_cs":["destilačně"],"computed":["azot amonowy (N-NH4+) (obliczeniowo z wartości zmierzonych)"],"computed_en":["ammonia nitrogen by calculation from measured values (N-NH4+)"],"computed_zh":["氨氮（N-NH4+）（由测量值计算）"],"computed_cs":["dusíku amoniakálního výpočtem z naměřených hodnot (N-NH4+)"],"activity":"Oznaczanie jonów amonowych metodą destylacyjną (NH4+), azotu amonowego obliczeniowo z wartości zmierzonych (N-NH4+)\nmetoda destylacyjna","reference":"SOP-O-21a/N-NH4+ část B (ČSN EN 14671; ČSN ISO 5664; ČSN 83 0540-10:1985)","norm_bases":["SOP-O-21a/N-NH4+ část B","ČSN EN 14671","ČSN ISO 5664","ČSN 83 0540-10:1985"],"lab_section":"Laboratorium ścieków","lab_section_en":"Waste Water Laboratory","lab_section_zh":"废水实验室","lab_section_cs":"Laboratoř odpadních vod","lab_address":"Jateční 2581/40, 301 00 Plzeň","regulatory_area":"Laboratorium ścieków – Badania","regulatory_area_en":"Waste Water Laboratory – Tests","regulatory_area_zh":"废水实验室 – 检测","regulatory_area_cs":"Laboratoř odpadních vod – Zkoušky","flexible":true,"flexibility":"A","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Osad, osad denny, skratki, piasek, grunt Oznaczanie jonów amonowych metodą destylacyjną (NH4+), azotu amonowego obliczeniowo z wartości zmierzonych (N-NH4+) metoda destylacyjna azot amonowy (N-NH4+) (obliczeniowo z wartości zmierzonych) Kal, sediment, shrabky, písek, zemina Stanovení amonných iontů destilačně (NH4+), dusíku amoniakálního výpočtem z naměřených hodnot (N-NH4+) destilačně dusíku amoniakálního výpočtem z naměřených hodnot (N-NH4+) SOP-O-21a/N-NH4+ část B (ČSN EN 14671; ČSN ISO 5664; ČSN 83 0540-10:1985) Osad, osad denny, skratki, piasek, grunt Oznaczanie jonow amonowych metoda destylacyjna (NH4+), azotu amonowego obliczeniowo z wartosci zmierzonych (N-NH4+) metoda destylacyjna azot amonowy (N-NH4+) (obliczeniowo z wartosci zmierzonych) Kal, sediment, shrabky, pisek, zemina Stanoveni amonnych iontu destilacne (NH4+), dusiku amoniakalniho vypoctem z namerenych hodnot (N-NH4+) destilacne dusiku amoniakalniho vypoctem z namerenych hodnot (N-NH4+) SOP-O-21a/N-NH4+ cast B (CSN EN 14671; CSN ISO 5664; CSN 83 0540-10:1985)","search_en":"Sludge, sediment, screenings, sand, soil Determination of ammonium ions by distillation (NH4+), ammonia nitrogen by calculation from measured values (N-NH4+) by distillation ammonia nitrogen by calculation from measured values (N-NH4+) SOP-O-21a/N-NH4+ část B (ČSN EN 14671; ČSN ISO 5664; ČSN 83 0540-10:1985)","search_zh":"污泥、沉积物、栅渣、砂、土壤 蒸馏法测定铵离子（NH4+），并由测量值计算氨氮（N-NH4+） 蒸馏法 氨氮（N-NH4+）（由测量值计算） SOP-O-21a/N-NH4+ část B (ČSN EN 14671; ČSN ISO 5664; ČSN 83 0540-10:1985)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":15,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"9f097e8faa2e5a5ffbfe921c","lab_id":"69ad52a4de79e566650fd2e2","country":"CZ","accr_number":"1202","accr_body":"ČIA","row_label":"17","test_object":"Woda pitna, surowa (powierzchniowa, podziemna), użytkowa, ścieki, wyciąg wodny z osadu, osadu dennego, skratek, piasku, gruntu","test_object_en":"Drinking water, raw water (surface, ground), service water, waste water, aqueous extract of sludge, sediment, screenings, sand, soil","test_object_zh":"饮用水、原水（地表水、地下水）、杂用水、废水、污泥、沉积物、栅渣、砂和土壤的水浸出液","test_object_cs":"Voda pitná, surová (povrchová, podzemní), užitková, odpadní, vodný výluh kalu, sedimentu, shrabků, písku, zeminy","methodology":"Oznaczanie azotu metodą Kjeldahla miareczkowo (Nk), azotu organicznego, nieorganicznego, ogólnego (N org., N nieorg., N og.) obliczeniowo z wartości zmierzonych","methodology_en":"Determination of Kjeldahl nitrogen by titration (Nk), organic, inorganic and total nitrogen (N org., N inorg., N tot.) by calculation from measured values","methodology_zh":"凯氏滴定法测定凯氏氮（Nk），并由测量值计算有机氮、无机氮和总氮","methodology_cs":"Stanovení dusíku podle Kjeldahla titračně (Nk), dusíku organického, anorganického, celkového (N org., N anorg., N cel.) výpočtem z naměřených hodnot","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"metoda Kjeldahla (miareczkowa)","technique_en":"Kjeldahl titration","technique_zh":"凯氏滴定法","technique_cs":"podle Kjeldahla titračně","techniques":["metoda Kjeldahla (miareczkowa)"],"techniques_en":["Kjeldahl titration"],"techniques_zh":["凯氏滴定法"],"techniques_cs":["podle Kjeldahla titračně"],"computed":["azot organiczny, nieorganiczny, ogólny (obliczeniowo z wartości zmierzonych)"],"computed_en":["organic, inorganic and total nitrogen by calculation from measured values"],"computed_zh":["有机氮、无机氮和总氮（由测量值计算）"],"computed_cs":["dusíku organického, anorganického, celkového (N org., N anorg., N cel.) výpočtem z naměřených hodnot"],"activity":"Oznaczanie azotu metodą Kjeldahla miareczkowo (Nk), azotu organicznego, nieorganicznego, ogólnego (N org., N nieorg., N og.) obliczeniowo z wartości zmierzonych\nmetoda Kjeldahla (miareczkowa)","reference":"SOP-O-24, 25/N část A (ČSN EN 25663; ČSN 83 0540-13:1985, část C)","norm_bases":["SOP-O-24, 25/N část A","ČSN EN 25663","ČSN 83 0540-13:1985, část C"],"lab_section":"Laboratorium ścieków","lab_section_en":"Waste Water Laboratory","lab_section_zh":"废水实验室","lab_section_cs":"Laboratoř odpadních vod","lab_address":"Jateční 2581/40, 301 00 Plzeň","regulatory_area":"Laboratorium ścieków – Badania","regulatory_area_en":"Waste Water Laboratory – Tests","regulatory_area_zh":"废水实验室 – 检测","regulatory_area_cs":"Laboratoř odpadních vod – Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Woda pitna, surowa (powierzchniowa, podziemna), użytkowa, ścieki, wyciąg wodny z osadu, osadu dennego, skratek, piasku, gruntu Oznaczanie azotu metodą Kjeldahla miareczkowo (Nk), azotu organicznego, nieorganicznego, ogólnego (N org., N nieorg., N og.) obliczeniowo z wartości zmierzonych metoda Kjeldahla (miareczkowa) azot organiczny, nieorganiczny, ogólny (obliczeniowo z wartości zmierzonych) Voda pitná, surová (povrchová, podzemní), užitková, odpadní, vodný výluh kalu, sedimentu, shrabků, písku, zeminy Stanovení dusíku podle Kjeldahla titračně (Nk), dusíku organického, anorganického, celkového (N org., N anorg., N cel.) výpočtem z naměřených hodnot podle Kjeldahla titračně dusíku organického, anorganického, celkového (N org., N anorg., N cel.) výpočtem z naměřených hodnot SOP-O-24, 25/N část A (ČSN EN 25663; ČSN 83 0540-13:1985, část C) Woda pitna, surowa (powierzchniowa, podziemna), uzytkowa, scieki, wyciag wodny z osadu, osadu dennego, skratek, piasku, gruntu Oznaczanie azotu metoda Kjeldahla miareczkowo (Nk), azotu organicznego, nieorganicznego, ogolnego (N org., N nieorg., N og.) obliczeniowo z wartosci zmierzonych metoda Kjeldahla (miareczkowa) azot organiczny, nieorganiczny, ogolny (obliczeniowo z wartosci zmierzonych) Voda pitna, surova (povrchova, podzemni), uzitkova, odpadni, vodny vyluh kalu, sedimentu, shrabku, pisku, zeminy Stanoveni dusiku podle Kjeldahla titracne (Nk), dusiku organickeho, anorganickeho, celkoveho (N org., N anorg., N cel.) vypoctem z namerenych hodnot podle Kjeldahla titracne dusiku organickeho, anorganickeho, celkoveho (N org., N anorg., N cel.) vypoctem z namerenych hodnot SOP-O-24, 25/N cast A (CSN EN 25663; CSN 83 0540-13:1985, cast C)","search_en":"Drinking water, raw water (surface, ground), service water, waste water, aqueous extract of sludge, sediment, screenings, sand, soil Determination of Kjeldahl nitrogen by titration (Nk), organic, inorganic and total nitrogen (N org., N inorg., N tot.) by calculation from measured values Kjeldahl titration organic, inorganic and total nitrogen by calculation from measured values SOP-O-24, 25/N část A (ČSN EN 25663; ČSN 83 0540-13:1985, část C)","search_zh":"饮用水、原水（地表水、地下水）、杂用水、废水、污泥、沉积物、栅渣、砂和土壤的水浸出液 凯氏滴定法测定凯氏氮（Nk），并由测量值计算有机氮、无机氮和总氮 凯氏滴定法 有机氮、无机氮和总氮（由测量值计算） SOP-O-24, 25/N část A (ČSN EN 25663; ČSN 83 0540-13:1985, část C)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":16,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"f22d902fea28d74b6a97f47e","lab_id":"69ad52a4de79e566650fd2e2","country":"CZ","accr_number":"1202","accr_body":"ČIA","row_label":"18","test_object":"Osad, osad denny, skratki, piasek, grunt","test_object_en":"Sludge, sediment, screenings, sand, soil","test_object_zh":"污泥、沉积物、栅渣、砂、土壤","test_object_cs":"Kal, sediment, shrabky, písek, zemina","methodology":"Oznaczanie azotu metodą Kjeldahla miareczkowo (Nk), azotu organicznego, nieorganicznego, ogólnego (N org., N nieorg., N og.) obliczeniowo z wartości zmierzonych","methodology_en":"Determination of Kjeldahl nitrogen by titration (Nk), organic, inorganic and total nitrogen (N org., N inorg., N tot.) by calculation from measured values","methodology_zh":"凯氏滴定法测定凯氏氮（Nk），并由测量值计算有机氮、无机氮和总氮","methodology_cs":"Stanovení dusíku podle Kjeldahla titračně (Nk), dusíku organického, anorganického, celkového (N org., N anorg., N cel.) výpočtem z naměřených hodnot","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"metoda Kjeldahla (miareczkowa)","technique_en":"Kjeldahl titration","technique_zh":"凯氏滴定法","technique_cs":"podle Kjeldahla titračně","techniques":["metoda Kjeldahla (miareczkowa)"],"techniques_en":["Kjeldahl titration"],"techniques_zh":["凯氏滴定法"],"techniques_cs":["podle Kjeldahla titračně"],"computed":["azot organiczny, nieorganiczny, ogólny (obliczeniowo z wartości zmierzonych)"],"computed_en":["organic, inorganic and total nitrogen by calculation from measured values"],"computed_zh":["有机氮、无机氮和总氮（由测量值计算）"],"computed_cs":["dusíku organického, anorganického, celkového (N org., N anorg., N cel.) výpočtem z naměřených hodnot"],"activity":"Oznaczanie azotu metodą Kjeldahla miareczkowo (Nk), azotu organicznego, nieorganicznego, ogólnego (N org., N nieorg., N og.) obliczeniowo z wartości zmierzonych\nmetoda Kjeldahla (miareczkowa)","reference":"SOP-O-24, 25/N část B (ČSN EN 13342; ČSN EN 16169; ČSN 83 0540-13:1985, část C)","norm_bases":["SOP-O-24, 25/N část B","ČSN EN 13342","ČSN EN 16169","ČSN 83 0540-13:1985, část C"],"lab_section":"Laboratorium ścieków","lab_section_en":"Waste Water Laboratory","lab_section_zh":"废水实验室","lab_section_cs":"Laboratoř odpadních vod","lab_address":"Jateční 2581/40, 301 00 Plzeň","regulatory_area":"Laboratorium ścieków – Badania","regulatory_area_en":"Waste Water Laboratory – Tests","regulatory_area_zh":"废水实验室 – 检测","regulatory_area_cs":"Laboratoř odpadních vod – Zkoušky","flexible":true,"flexibility":"A","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Osad, osad denny, skratki, piasek, grunt Oznaczanie azotu metodą Kjeldahla miareczkowo (Nk), azotu organicznego, nieorganicznego, ogólnego (N org., N nieorg., N og.) obliczeniowo z wartości zmierzonych metoda Kjeldahla (miareczkowa) azot organiczny, nieorganiczny, ogólny (obliczeniowo z wartości zmierzonych) Kal, sediment, shrabky, písek, zemina Stanovení dusíku podle Kjeldahla titračně (Nk), dusíku organického, anorganického, celkového (N org., N anorg., N cel.) výpočtem z naměřených hodnot podle Kjeldahla titračně dusíku organického, anorganického, celkového (N org., N anorg., N cel.) výpočtem z naměřených hodnot SOP-O-24, 25/N část B (ČSN EN 13342; ČSN EN 16169; ČSN 83 0540-13:1985, část C) Osad, osad denny, skratki, piasek, grunt Oznaczanie azotu metoda Kjeldahla miareczkowo (Nk), azotu organicznego, nieorganicznego, ogolnego (N org., N nieorg., N og.) obliczeniowo z wartosci zmierzonych metoda Kjeldahla (miareczkowa) azot organiczny, nieorganiczny, ogolny (obliczeniowo z wartosci zmierzonych) Kal, sediment, shrabky, pisek, zemina Stanoveni dusiku podle Kjeldahla titracne (Nk), dusiku organickeho, anorganickeho, celkoveho (N org., N anorg., N cel.) vypoctem z namerenych hodnot podle Kjeldahla titracne dusiku organickeho, anorganickeho, celkoveho (N org., N anorg., N cel.) vypoctem z namerenych hodnot SOP-O-24, 25/N cast B (CSN EN 13342; CSN EN 16169; CSN 83 0540-13:1985, cast C)","search_en":"Sludge, sediment, screenings, sand, soil Determination of Kjeldahl nitrogen by titration (Nk), organic, inorganic and total nitrogen (N org., N inorg., N tot.) by calculation from measured values Kjeldahl titration organic, inorganic and total nitrogen by calculation from measured values SOP-O-24, 25/N část B (ČSN EN 13342; ČSN EN 16169; ČSN 83 0540-13:1985, část C)","search_zh":"污泥、沉积物、栅渣、砂、土壤 凯氏滴定法测定凯氏氮（Nk），并由测量值计算有机氮、无机氮和总氮 凯氏滴定法 有机氮、无机氮和总氮（由测量值计算） SOP-O-24, 25/N část B (ČSN EN 13342; ČSN EN 16169; ČSN 83 0540-13:1985, část C)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":17,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"26357d7c475dff22acd5c528","lab_id":"69ad52a4de79e566650fd2e2","country":"CZ","accr_number":"1202","accr_body":"ČIA","row_label":"19","test_object":"Woda pitna, surowa (powierzchniowa, podziemna), użytkowa, ścieki, wyciąg wodny z osadu, osadu dennego, skratek, piasku, gruntu","test_object_en":"Drinking water, raw water (surface, ground), service water, waste water, aqueous extract of sludge, sediment, screenings, sand, soil","test_object_zh":"饮用水、原水（地表水、地下水）、杂用水、废水、污泥、沉积物、栅渣、砂和土壤的水浸出液","test_object_cs":"Voda pitná, surová (povrchová, podzemní), užitková, odpadní, vodný výluh kalu, sedimentu, shrabků, písku, zeminy","methodology":"Oznaczanie jonów (NH4+, NO2-, NO3-, PO43-, P og.) metodą CFA, oznaczanie form azotu, azotu nieorganicznego (N-NH4+, N-NO2-, N-NO3-, N nieorg.) obliczeniowo z wartości zmierzonych","methodology_en":"Determination of ions (NH4+, NO2-, NO3-, PO43-, P tot.) by CFA method, determination of nitrogen forms and inorganic nitrogen (N-NH4+, N-NO2-, N-NO3-, N inorg.) by calculation from measured values","methodology_zh":"连续流动分析法（CFA）测定离子（NH4+、NO2-、NO3-、PO43-、总磷），并由测量值计算各形态氮及无机氮","methodology_cs":"Stanovení iontů (NH4+, NO2-, NO3-, PO43-, P cel.) metodou CFA, stanovení forem dusíku, dusíku anorganického (N-NH4+, N-NO2-, N-NO3-, N anorg.) výpočtem z naměřených hodnot","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"analiza przepływowa ciągła (CFA)","technique_en":"CFA method","technique_zh":"连续流动分析法（CFA）","technique_cs":"metodou CFA","techniques":["analiza przepływowa ciągła (CFA)"],"techniques_en":["CFA method"],"techniques_zh":["连续流动分析法（CFA）"],"techniques_cs":["metodou CFA"],"computed":["formy azotu, azot nieorganiczny (obliczeniowo z wartości zmierzonych)"],"computed_en":["nitrogen forms, inorganic nitrogen by calculation from measured values"],"computed_zh":["各形态氮、无机氮（由测量值计算）"],"computed_cs":["forem dusíku, dusíku anorganického (N-NH4+, N-NO2-, N-NO3-, N anorg.) výpočtem z naměřených hodnot"],"activity":"Oznaczanie jonów (NH4+, NO2-, NO3-, PO43-, P og.) metodą CFA, oznaczanie form azotu, azotu nieorganicznego (N-NH4+, N-NO2-, N-NO3-, N nieorg.) obliczeniowo z wartości zmierzonych\nanaliza przepływowa ciągła (CFA)","reference":"SOP-O-86/ionty CFA část A (ČSN EN ISO 11732; ČSN EN ISO 13395; ČSN EN ISO 15681-2)","norm_bases":["SOP-O-86/ionty CFA část A","ČSN EN ISO 11732","ČSN EN ISO 13395","ČSN EN ISO 15681-2"],"lab_section":"Laboratorium ścieków","lab_section_en":"Waste Water Laboratory","lab_section_zh":"废水实验室","lab_section_cs":"Laboratoř odpadních vod","lab_address":"Jateční 2581/40, 301 00 Plzeň","regulatory_area":"Laboratorium ścieków – Badania","regulatory_area_en":"Waste Water Laboratory – Tests","regulatory_area_zh":"废水实验室 – 检测","regulatory_area_cs":"Laboratoř odpadních vod – Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Woda pitna, surowa (powierzchniowa, podziemna), użytkowa, ścieki, wyciąg wodny z osadu, osadu dennego, skratek, piasku, gruntu Oznaczanie jonów (NH4+, NO2-, NO3-, PO43-, P og.) metodą CFA, oznaczanie form azotu, azotu nieorganicznego (N-NH4+, N-NO2-, N-NO3-, N nieorg.) obliczeniowo z wartości zmierzonych analiza przepływowa ciągła (CFA) formy azotu, azot nieorganiczny (obliczeniowo z wartości zmierzonych) Voda pitná, surová (povrchová, podzemní), užitková, odpadní, vodný výluh kalu, sedimentu, shrabků, písku, zeminy Stanovení iontů (NH4+, NO2-, NO3-, PO43-, P cel.) metodou CFA, stanovení forem dusíku, dusíku anorganického (N-NH4+, N-NO2-, N-NO3-, N anorg.) výpočtem z naměřených hodnot metodou CFA forem dusíku, dusíku anorganického (N-NH4+, N-NO2-, N-NO3-, N anorg.) výpočtem z naměřených hodnot SOP-O-86/ionty CFA část A (ČSN EN ISO 11732; ČSN EN ISO 13395; ČSN EN ISO 15681-2) Woda pitna, surowa (powierzchniowa, podziemna), uzytkowa, scieki, wyciag wodny z osadu, osadu dennego, skratek, piasku, gruntu Oznaczanie jonow (NH4+, NO2-, NO3-, PO43-, P og.) metoda CFA, oznaczanie form azotu, azotu nieorganicznego (N-NH4+, N-NO2-, N-NO3-, N nieorg.) obliczeniowo z wartosci zmierzonych analiza przeplywowa ciagla (CFA) formy azotu, azot nieorganiczny (obliczeniowo z wartosci zmierzonych) Voda pitna, surova (povrchova, podzemni), uzitkova, odpadni, vodny vyluh kalu, sedimentu, shrabku, pisku, zeminy Stanoveni iontu (NH4+, NO2-, NO3-, PO43-, P cel.) metodou CFA, stanoveni forem dusiku, dusiku anorganickeho (N-NH4+, N-NO2-, N-NO3-, N anorg.) vypoctem z namerenych hodnot metodou CFA forem dusiku, dusiku anorganickeho (N-NH4+, N-NO2-, N-NO3-, N anorg.) vypoctem z namerenych hodnot SOP-O-86/ionty CFA cast A (CSN EN ISO 11732; CSN EN ISO 13395; CSN EN ISO 15681-2)","search_en":"Drinking water, raw water (surface, ground), service water, waste water, aqueous extract of sludge, sediment, screenings, sand, soil Determination of ions (NH4+, NO2-, NO3-, PO43-, P tot.) by CFA method, determination of nitrogen forms and inorganic nitrogen (N-NH4+, N-NO2-, N-NO3-, N inorg.) by calculation from measured values CFA method nitrogen forms, inorganic nitrogen by calculation from measured values SOP-O-86/ionty CFA část A (ČSN EN ISO 11732; ČSN EN ISO 13395; ČSN EN ISO 15681-2)","search_zh":"饮用水、原水（地表水、地下水）、杂用水、废水、污泥、沉积物、栅渣、砂和土壤的水浸出液 连续流动分析法（CFA）测定离子（NH4+、NO2-、NO3-、PO43-、总磷），并由测量值计算各形态氮及无机氮 连续流动分析法（CFA） 各形态氮、无机氮（由测量值计算） SOP-O-86/ionty CFA část A (ČSN EN ISO 11732; ČSN EN ISO 13395; ČSN EN ISO 15681-2)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":18,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"926b6a3c1516e5d3313ff146","lab_id":"69ad52a4de79e566650fd2e2","country":"CZ","accr_number":"1202","accr_body":"ČIA","row_label":"20","test_object":"Osad","test_object_en":"Sludge","test_object_zh":"污泥","test_object_cs":"Kal","methodology":"Oznaczanie jonów (NH4+, NO2-, NO3-, PO43-, P og.) metodą CFA, oznaczanie form azotu, azotu nieorganicznego (N-NH4+, N-NO2-, N-NO3-, N nieorg.) obliczeniowo z wartości zmierzonych","methodology_en":"Determination of ions (NH4+, NO2-, NO3-, PO43-, P tot.) by CFA method, determination of nitrogen forms and inorganic nitrogen (N-NH4+, N-NO2-, N-NO3-, N inorg.) by calculation from measured values","methodology_zh":"连续流动分析法（CFA）测定离子（NH4+、NO2-、NO3-、PO43-、总磷），并由测量值计算各形态氮及无机氮","methodology_cs":"Stanovení iontů (NH4+, NO2-, NO3-, PO43-, P cel.) metodou CFA, stanovení forem dusíku, dusíku anorganického (N-NH4+, N-NO2-, N-NO3-, N anorg.) výpočtem z naměřených hodnot","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"analiza przepływowa ciągła (CFA)","technique_en":"CFA method","technique_zh":"连续流动分析法（CFA）","technique_cs":"metodou CFA","techniques":["analiza przepływowa ciągła (CFA)"],"techniques_en":["CFA method"],"techniques_zh":["连续流动分析法（CFA）"],"techniques_cs":["metodou CFA"],"computed":["formy azotu, azot nieorganiczny (obliczeniowo z wartości zmierzonych)"],"computed_en":["nitrogen forms, inorganic nitrogen by calculation from measured values"],"computed_zh":["各形态氮、无机氮（由测量值计算）"],"computed_cs":["forem dusíku, dusíku anorganického (N-NH4+, N-NO2-, N-NO3-, N anorg.) výpočtem z naměřených hodnot"],"activity":"Oznaczanie jonów (NH4+, NO2-, NO3-, PO43-, P og.) metodą CFA, oznaczanie form azotu, azotu nieorganicznego (N-NH4+, N-NO2-, N-NO3-, N nieorg.) obliczeniowo z wartości zmierzonych\nanaliza przepływowa ciągła (CFA)","reference":"SOP-O-86/ionty CFA část B (ČSN EN ISO 11732; ČSN EN ISO 13395; ČSN EN ISO 15681-2; ČSN EN 14671)","norm_bases":["SOP-O-86/ionty CFA část B","ČSN EN ISO 11732","ČSN EN ISO 13395","ČSN EN ISO 15681-2","ČSN EN 14671"],"lab_section":"Laboratorium ścieków","lab_section_en":"Waste Water Laboratory","lab_section_zh":"废水实验室","lab_section_cs":"Laboratoř odpadních vod","lab_address":"Jateční 2581/40, 301 00 Plzeň","regulatory_area":"Laboratorium ścieków – Badania","regulatory_area_en":"Waste Water Laboratory – Tests","regulatory_area_zh":"废水实验室 – 检测","regulatory_area_cs":"Laboratoř odpadních vod – Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Osad Oznaczanie jonów (NH4+, NO2-, NO3-, PO43-, P og.) metodą CFA, oznaczanie form azotu, azotu nieorganicznego (N-NH4+, N-NO2-, N-NO3-, N nieorg.) obliczeniowo z wartości zmierzonych analiza przepływowa ciągła (CFA) formy azotu, azot nieorganiczny (obliczeniowo z wartości zmierzonych) Kal Stanovení iontů (NH4+, NO2-, NO3-, PO43-, P cel.) metodou CFA, stanovení forem dusíku, dusíku anorganického (N-NH4+, N-NO2-, N-NO3-, N anorg.) výpočtem z naměřených hodnot metodou CFA forem dusíku, dusíku anorganického (N-NH4+, N-NO2-, N-NO3-, N anorg.) výpočtem z naměřených hodnot SOP-O-86/ionty CFA část B (ČSN EN ISO 11732; ČSN EN ISO 13395; ČSN EN ISO 15681-2; ČSN EN 14671) Osad Oznaczanie jonow (NH4+, NO2-, NO3-, PO43-, P og.) metoda CFA, oznaczanie form azotu, azotu nieorganicznego (N-NH4+, N-NO2-, N-NO3-, N nieorg.) obliczeniowo z wartosci zmierzonych analiza przeplywowa ciagla (CFA) formy azotu, azot nieorganiczny (obliczeniowo z wartosci zmierzonych) Kal Stanoveni iontu (NH4+, NO2-, NO3-, PO43-, P cel.) metodou CFA, stanoveni forem dusiku, dusiku anorganickeho (N-NH4+, N-NO2-, N-NO3-, N anorg.) vypoctem z namerenych hodnot metodou CFA forem dusiku, dusiku anorganickeho (N-NH4+, N-NO2-, N-NO3-, N anorg.) vypoctem z namerenych hodnot SOP-O-86/ionty CFA cast B (CSN EN ISO 11732; CSN EN ISO 13395; CSN EN ISO 15681-2; CSN EN 14671)","search_en":"Sludge Determination of ions (NH4+, NO2-, NO3-, PO43-, P tot.) by CFA method, determination of nitrogen forms and inorganic nitrogen (N-NH4+, N-NO2-, N-NO3-, N inorg.) by calculation from measured values CFA method nitrogen forms, inorganic nitrogen by calculation from measured values SOP-O-86/ionty CFA část B (ČSN EN ISO 11732; ČSN EN ISO 13395; ČSN EN ISO 15681-2; ČSN EN 14671)","search_zh":"污泥 连续流动分析法（CFA）测定离子（NH4+、NO2-、NO3-、PO43-、总磷），并由测量值计算各形态氮及无机氮 连续流动分析法（CFA） 各形态氮、无机氮（由测量值计算） SOP-O-86/ionty CFA část B (ČSN EN ISO 11732; ČSN EN ISO 13395; ČSN EN ISO 15681-2; ČSN EN 14671)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":19,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"eb208ece949bc08232127136","lab_id":"69ad52a4de79e566650fd2e2","country":"CZ","accr_number":"1202","accr_body":"ČIA","row_label":"21","test_object":"Woda pitna, surowa (powierzchniowa, podziemna), użytkowa, ścieki, wyciąg wodny z osadu, osadu dennego, skratek, piasku, gruntu","test_object_en":"Drinking water, raw water (surface, ground), service water, waste water, aqueous extract of sludge, sediment, screenings, sand, soil","test_object_zh":"饮用水、原水（地表水、地下水）、杂用水、废水、污泥、沉积物、栅渣、砂和土壤的水浸出液","test_object_cs":"Voda pitná, surová (povrchová, podzemní), užitková, odpadní, vodný výluh kalu, sedimentu, shrabků, písku, zeminy","methodology":"Oznaczanie anionowych substancji powierzchniowo czynnych metodą fotometryczną (PAL A)","methodology_en":"Determination of anionic surfactants by photometry (PAL A)","methodology_zh":"光度法测定阴离子表面活性剂（PAL A）","methodology_cs":"Stanovení tenzidů anionaktivních fotometricky (PAL A)","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"metoda fotometryczna","technique_en":"by photometry","technique_zh":"光度法","technique_cs":"fotometricky","techniques":["metoda fotometryczna"],"techniques_en":["by photometry"],"techniques_zh":["光度法"],"techniques_cs":["fotometricky"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie anionowych substancji powierzchniowo czynnych metodą fotometryczną (PAL A)\nmetoda fotometryczna","reference":"SOP-O-28/PAL A (M. Horáková, P. Lischke, A. Grunwald: „Chemické a fyzikální metody analýzy vod“, SNTL Praha, 1986, kap. 2.42.1)","norm_bases":["SOP-O-28/PAL A","M. Horáková, P. Lischke, A. Grunwald: „Chemické a fyzikální metody analýzy vod“, SNTL Praha, 1986, kap. 2.42.1"],"lab_section":"Laboratorium ścieków","lab_section_en":"Waste Water Laboratory","lab_section_zh":"废水实验室","lab_section_cs":"Laboratoř odpadních vod","lab_address":"Jateční 2581/40, 301 00 Plzeň","regulatory_area":"Laboratorium ścieków – Badania","regulatory_area_en":"Waste Water Laboratory – Tests","regulatory_area_zh":"废水实验室 – 检测","regulatory_area_cs":"Laboratoř odpadních vod – Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Woda pitna, surowa (powierzchniowa, podziemna), użytkowa, ścieki, wyciąg wodny z osadu, osadu dennego, skratek, piasku, gruntu Oznaczanie anionowych substancji powierzchniowo czynnych metodą fotometryczną (PAL A) metoda fotometryczna Voda pitná, surová (povrchová, podzemní), užitková, odpadní, vodný výluh kalu, sedimentu, shrabků, písku, zeminy Stanovení tenzidů anionaktivních fotometricky (PAL A) fotometricky SOP-O-28/PAL A (M. Horáková, P. Lischke, A. Grunwald: „Chemické a fyzikální metody analýzy vod“, SNTL Praha, 1986, kap. 2.42.1) Woda pitna, surowa (powierzchniowa, podziemna), uzytkowa, scieki, wyciag wodny z osadu, osadu dennego, skratek, piasku, gruntu Oznaczanie anionowych substancji powierzchniowo czynnych metoda fotometryczna (PAL A) metoda fotometryczna Voda pitna, surova (povrchova, podzemni), uzitkova, odpadni, vodny vyluh kalu, sedimentu, shrabku, pisku, zeminy Stanoveni tenzidu anionaktivnich fotometricky (PAL A) fotometricky SOP-O-28/PAL A (M. Horakova, P. Lischke, A. Grunwald: „Chemicke a fyzikalni metody analyzy vod“, SNTL Praha, 1986, kap. 2.42.1)","search_en":"Drinking water, raw water (surface, ground), service water, waste water, aqueous extract of sludge, sediment, screenings, sand, soil Determination of anionic surfactants by photometry (PAL A) by photometry SOP-O-28/PAL A (M. Horáková, P. Lischke, A. Grunwald: „Chemické a fyzikální metody analýzy vod“, SNTL Praha, 1986, kap. 2.42.1)","search_zh":"饮用水、原水（地表水、地下水）、杂用水、废水、污泥、沉积物、栅渣、砂和土壤的水浸出液 光度法测定阴离子表面活性剂（PAL A） 光度法 SOP-O-28/PAL A (M. Horáková, P. Lischke, A. Grunwald: „Chemické a fyzikální metody analýzy vod“, SNTL Praha, 1986, kap. 2.42.1)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":20,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"4a849bb990748d479abcfd65","lab_id":"69ad52a4de79e566650fd2e2","country":"CZ","accr_number":"1202","accr_body":"ČIA","row_label":"22","test_object":"Woda pitna, surowa (powierzchniowa, podziemna), użytkowa, ścieki","test_object_en":"Drinking water, raw water (surface, ground), service water, waste water","test_object_zh":"饮用水、原水（地表水、地下水）、杂用水、废水","test_object_cs":"Voda pitná, surová (povrchová, podzemní), užitková, odpadní","methodology":"Oznaczanie substancji ekstrahowalnych (tłuszczów i olejów) metodą wagową (EL)","methodology_en":"Determination of extractable substances (fats and oils) by gravimetry (EL)","methodology_zh":"重量法测定可萃取物（油脂）（EL）","methodology_cs":"Stanovení extrahovatelných látek (tuků a olejů) gravimetricky (EL)","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"metoda wagowa","technique_en":"by gravimetry","technique_zh":"重量法","technique_cs":"gravimetricky","techniques":["metoda wagowa"],"techniques_en":["by gravimetry"],"techniques_zh":["重量法"],"techniques_cs":["gravimetricky"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie substancji ekstrahowalnych (tłuszczów i olejów) metodą wagową (EL)\nmetoda wagowa","reference":"SOP-O-29/EL (ČSN ISO 11349; ČSN 75 7509; ČSN 75 7508)","norm_bases":["SOP-O-29/EL","ČSN ISO 11349","ČSN 75 7509","ČSN 75 7508"],"lab_section":"Laboratorium ścieków","lab_section_en":"Waste Water Laboratory","lab_section_zh":"废水实验室","lab_section_cs":"Laboratoř odpadních vod","lab_address":"Jateční 2581/40, 301 00 Plzeň","regulatory_area":"Laboratorium ścieków – Badania","regulatory_area_en":"Waste Water Laboratory – Tests","regulatory_area_zh":"废水实验室 – 检测","regulatory_area_cs":"Laboratoř odpadních vod – Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Woda pitna, surowa (powierzchniowa, podziemna), użytkowa, ścieki Oznaczanie substancji ekstrahowalnych (tłuszczów i olejów) metodą wagową (EL) metoda wagowa Voda pitná, surová (povrchová, podzemní), užitková, odpadní Stanovení extrahovatelných látek (tuků a olejů) gravimetricky (EL) gravimetricky SOP-O-29/EL (ČSN ISO 11349; ČSN 75 7509; ČSN 75 7508) Woda pitna, surowa (powierzchniowa, podziemna), uzytkowa, scieki Oznaczanie substancji ekstrahowalnych (tluszczow i olejow) metoda wagowa (EL) metoda wagowa Voda pitna, surova (povrchova, podzemni), uzitkova, odpadni Stanoveni extrahovatelnych latek (tuku a oleju) gravimetricky (EL) gravimetricky SOP-O-29/EL (CSN ISO 11349; CSN 75 7509; CSN 75 7508)","search_en":"Drinking water, raw water (surface, ground), service water, waste water Determination of extractable substances (fats and oils) by gravimetry (EL) by gravimetry SOP-O-29/EL (ČSN ISO 11349; ČSN 75 7509; ČSN 75 7508)","search_zh":"饮用水、原水（地表水、地下水）、杂用水、废水 重量法测定可萃取物（油脂）（EL） 重量法 SOP-O-29/EL (ČSN ISO 11349; ČSN 75 7509; ČSN 75 7508)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":21,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"ce23b2e469b62c050504aa08","lab_id":"69ad52a4de79e566650fd2e2","country":"CZ","accr_number":"1202","accr_body":"ČIA","row_label":"23","test_object":"Woda pitna, surowa (powierzchniowa, podziemna), użytkowa, ścieki","test_object_en":"Drinking water, raw water (surface, ground), service water, waste water","test_object_zh":"饮用水、原水（地表水、地下水）、杂用水、废水","test_object_cs":"Voda pitná, surová (povrchová, podzemní), užitková, odpadní","methodology":"Oznaczanie adsorbowalnych związków chloroorganicznych metodą kulometryczną po rozkładzie termicznym (AOX)","methodology_en":"Determination of adsorbable organic halogens by coulometry after thermal decomposition (AOX)","methodology_zh":"热分解后库仑法测定可吸附有机卤素（AOX）","methodology_cs":"Stanovení adsorbovatelných organických halogenů coulometricky po termickém rozkladu (AOX)","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"kulometria po rozkładzie termicznym","technique_en":"coulometry after thermal decomposition","technique_zh":"热分解后库仑法","technique_cs":"coulometricky po termickém rozkladu","techniques":["kulometria po rozkładzie termicznym"],"techniques_en":["coulometry after thermal decomposition"],"techniques_zh":["热分解后库仑法"],"techniques_cs":["coulometricky po termickém rozkladu"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie adsorbowalnych związków chloroorganicznych metodą kulometryczną po rozkładzie termicznym (AOX)\nkulometria po rozkładzie termicznym","reference":"SOP-O-40/AOX část A (ČSN EN ISO 9562)","norm_bases":["SOP-O-40/AOX část A","ČSN EN ISO 9562"],"lab_section":"Laboratorium ścieków","lab_section_en":"Waste Water Laboratory","lab_section_zh":"废水实验室","lab_section_cs":"Laboratoř odpadních vod","lab_address":"Jateční 2581/40, 301 00 Plzeň","regulatory_area":"Laboratorium ścieków – Badania","regulatory_area_en":"Waste Water Laboratory – Tests","regulatory_area_zh":"废水实验室 – 检测","regulatory_area_cs":"Laboratoř odpadních vod – Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Woda pitna, surowa (powierzchniowa, podziemna), użytkowa, ścieki Oznaczanie adsorbowalnych związków chloroorganicznych metodą kulometryczną po rozkładzie termicznym (AOX) kulometria po rozkładzie termicznym Voda pitná, surová (povrchová, podzemní), užitková, odpadní Stanovení adsorbovatelných organických halogenů coulometricky po termickém rozkladu (AOX) coulometricky po termickém rozkladu SOP-O-40/AOX část A (ČSN EN ISO 9562) Woda pitna, surowa (powierzchniowa, podziemna), uzytkowa, scieki Oznaczanie adsorbowalnych zwiazkow chloroorganicznych metoda kulometryczna po rozkladzie termicznym (AOX) kulometria po rozkladzie termicznym Voda pitna, surova (povrchova, podzemni), uzitkova, odpadni Stanoveni adsorbovatelnych organickych halogenu coulometricky po termickem rozkladu (AOX) coulometricky po termickem rozkladu SOP-O-40/AOX cast A (CSN EN ISO 9562)","search_en":"Drinking water, raw water (surface, ground), service water, waste water Determination of adsorbable organic halogens by coulometry after thermal decomposition (AOX) coulometry after thermal decomposition SOP-O-40/AOX část A (ČSN EN ISO 9562)","search_zh":"饮用水、原水（地表水、地下水）、杂用水、废水 热分解后库仑法测定可吸附有机卤素（AOX） 热分解后库仑法 SOP-O-40/AOX část A (ČSN EN ISO 9562)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":22,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"41afcc1b2f515de03d7bf3ad","lab_id":"69ad52a4de79e566650fd2e2","country":"CZ","accr_number":"1202","accr_body":"ČIA","row_label":"24","test_object":"Osad, osad denny, skratki, piasek, grunt","test_object_en":"Sludge, sediment, screenings, sand, soil","test_object_zh":"污泥、沉积物、栅渣、砂、土壤","test_object_cs":"Kal, sediment, shrabky, písek, zemina","methodology":"Oznaczanie adsorbowalnych związków chloroorganicznych metodą kulometryczną po rozkładzie termicznym (AOX)","methodology_en":"Determination of adsorbable organic halogens by coulometry after thermal decomposition (AOX)","methodology_zh":"热分解后库仑法测定可吸附有机卤素（AOX）","methodology_cs":"Stanovení adsorbovatelných organických halogenů coulometricky po termickém rozkladu (AOX)","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"kulometria po rozkładzie termicznym","technique_en":"coulometry after thermal decomposition","technique_zh":"热分解后库仑法","technique_cs":"coulometricky po termickém rozkladu","techniques":["kulometria po rozkładzie termicznym"],"techniques_en":["coulometry after thermal decomposition"],"techniques_zh":["热分解后库仑法"],"techniques_cs":["coulometricky po termickém rozkladu"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie adsorbowalnych związków chloroorganicznych metodą kulometryczną po rozkładzie termicznym (AOX)\nkulometria po rozkładzie termicznym","reference":"SOP-O-40/AOX část B (ČSN EN 16166)","norm_bases":["SOP-O-40/AOX část B","ČSN EN 16166"],"lab_section":"Laboratorium ścieków","lab_section_en":"Waste Water Laboratory","lab_section_zh":"废水实验室","lab_section_cs":"Laboratoř odpadních vod","lab_address":"Jateční 2581/40, 301 00 Plzeň","regulatory_area":"Laboratorium ścieków – Badania","regulatory_area_en":"Waste Water Laboratory – Tests","regulatory_area_zh":"废水实验室 – 检测","regulatory_area_cs":"Laboratoř odpadních vod – Zkoušky","flexible":true,"flexibility":"A","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Osad, osad denny, skratki, piasek, grunt Oznaczanie adsorbowalnych związków chloroorganicznych metodą kulometryczną po rozkładzie termicznym (AOX) kulometria po rozkładzie termicznym Kal, sediment, shrabky, písek, zemina Stanovení adsorbovatelných organických halogenů coulometricky po termickém rozkladu (AOX) coulometricky po termickém rozkladu SOP-O-40/AOX část B (ČSN EN 16166) Osad, osad denny, skratki, piasek, grunt Oznaczanie adsorbowalnych zwiazkow chloroorganicznych metoda kulometryczna po rozkladzie termicznym (AOX) kulometria po rozkladzie termicznym Kal, sediment, shrabky, pisek, zemina Stanoveni adsorbovatelnych organickych halogenu coulometricky po termickem rozkladu (AOX) coulometricky po termickem rozkladu SOP-O-40/AOX cast B (CSN EN 16166)","search_en":"Sludge, sediment, screenings, sand, soil Determination of adsorbable organic halogens by coulometry after thermal decomposition (AOX) coulometry after thermal decomposition SOP-O-40/AOX část B (ČSN EN 16166)","search_zh":"污泥、沉积物、栅渣、砂、土壤 热分解后库仑法测定可吸附有机卤素（AOX） 热分解后库仑法 SOP-O-40/AOX část B (ČSN EN 16166)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":23,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"8f577f798657bfc7c02fe823","lab_id":"69ad52a4de79e566650fd2e2","country":"CZ","accr_number":"1202","accr_body":"ČIA","row_label":"25","test_object":"Woda pitna, surowa (powierzchniowa, podziemna), użytkowa, ścieki, wyciąg wodny z osadu, osadu dennego, skratek, piasku, gruntu","test_object_en":"Drinking water, raw water (surface, ground), service water, waste water, aqueous extract of sludge, sediment, screenings, sand, soil","test_object_zh":"饮用水、原水（地表水、地下水）、杂用水、废水、污泥、沉积物、栅渣、砂和土壤的水浸出液","test_object_cs":"Voda pitná, surová (povrchová, podzemní), užitková, odpadní, vodný výluh kalu, sedimentu, shrabků, písku, zeminy","methodology":"Oznaczanie wielopierścieniowych węglowodorów aromatycznych (LC z detekcją fluorescencyjną) (WWA)","methodology_en":"Determination of polycyclic aromatic hydrocarbons (LC with fluorescence detection) (PAH)","methodology_zh":"多环芳烃的测定（液相色谱-荧光检测）（PAH）","methodology_cs":"Stanovení polyaromatických uhlovodíků (LC s fluorescenční detekcí) (PAU)","parameters":[{"name":"fluoranten","range":""},{"name":"benzo[b]fluoranten","range":""},{"name":"benzo[k]fluoranten","range":""},{"name":"benzo[a]piren","range":""},{"name":"benzo[g,h,i]perylen","range":""},{"name":"indeno[1,2,3-c,d]piren","range":""}],"parameters_en":[{"name":"fluoranthene","range":""},{"name":"benzo[b]fluoranthene","range":""},{"name":"benzo[k]fluoranthene","range":""},{"name":"benzo[a]pyrene","range":""},{"name":"benzo[g,h,i]perylene","range":""},{"name":"indeno[1,2,3-c,d]pyrene","range":""}],"parameters_zh":[{"name":"荧蒽","range":""},{"name":"苯并[b]荧蒽","range":""},{"name":"苯并[k]荧蒽","range":""},{"name":"苯并[a]芘","range":""},{"name":"苯并[g,h,i]苝","range":""},{"name":"茚并[1,2,3-c,d]芘","range":""}],"parameters_cs":[{"name":"fluoranten","range":""},{"name":"benzo[b]fluoranten","range":""},{"name":"benzo[k]fluoranten","range":""},{"name":"benzo[a]pyren","range":""},{"name":"benzo[g,h,i]perylen","range":""},{"name":"indeno[c,d]pyren","range":""}],"technique":"chromatografia cieczowa z detekcją fluorescencyjną","technique_en":"LC with fluorescence detection","technique_zh":"液相色谱-荧光检测","technique_cs":"LC s fluorescenční detekcí","techniques":["chromatografia cieczowa z detekcją fluorescencyjną"],"techniques_en":["LC with fluorescence detection"],"techniques_zh":["液相色谱-荧光检测"],"techniques_cs":["LC s fluorescenční detekcí"],"computed":["suma WWA (obliczeniowo z wartości zmierzonych)"],"computed_en":["sum of PAH – by calculation from measured values"],"computed_zh":["多环芳烃总和（由测量值计算）"],"computed_cs":["suma PAU – výpočtem z naměřených hodnot"],"activity":"Oznaczanie wielopierścieniowych węglowodorów aromatycznych (LC z detekcją fluorescencyjną) (WWA)\nZakres:\nfluoranten\nbenzo[b]fluoranten\nbenzo[k]fluoranten\nbenzo[a]piren\nbenzo[g,h,i]perylen\nindeno[1,2,3-c,d]piren\nchromatografia cieczowa z detekcją fluorescencyjną","reference":"SOP-O-32/analyty HPLC-32/PAU (ČSN EN ISO 17993)","norm_bases":["SOP-O-32/analyty HPLC-32/PAU","ČSN EN ISO 17993"],"lab_section":"Laboratorium ścieków","lab_section_en":"Waste Water Laboratory","lab_section_zh":"废水实验室","lab_section_cs":"Laboratoř odpadních vod","lab_address":"Jateční 2581/40, 301 00 Plzeň","regulatory_area":"Laboratorium ścieków – Badania","regulatory_area_en":"Waste Water Laboratory – Tests","regulatory_area_zh":"废水实验室 – 检测","regulatory_area_cs":"Laboratoř odpadních vod – Zkoušky","flexible":true,"flexibility":"B","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Woda pitna, surowa (powierzchniowa, podziemna), użytkowa, ścieki, wyciąg wodny z osadu, osadu dennego, skratek, piasku, gruntu Oznaczanie wielopierścieniowych węglowodorów aromatycznych (LC z detekcją fluorescencyjną) (WWA) chromatografia cieczowa z detekcją fluorescencyjną fluoranten  benzo[b]fluoranten  benzo[k]fluoranten  benzo[a]piren  benzo[g,h,i]perylen  indeno[1,2,3-c,d]piren  suma WWA (obliczeniowo z wartości zmierzonych) Voda pitná, surová (povrchová, podzemní), užitková, odpadní, vodný výluh kalu, sedimentu, shrabků, písku, zeminy Stanovení polyaromatických uhlovodíků (LC s fluorescenční detekcí) (PAU) LC s fluorescenční detekcí fluoranten  benzo[b]fluoranten  benzo[k]fluoranten  benzo[a]pyren  benzo[g,h,i]perylen  indeno[c,d]pyren  suma PAU – výpočtem z naměřených hodnot SOP-O-32/analyty HPLC-32/PAU (ČSN EN ISO 17993) Woda pitna, surowa (powierzchniowa, podziemna), uzytkowa, scieki, wyciag wodny z osadu, osadu dennego, skratek, piasku, gruntu Oznaczanie wielopierscieniowych weglowodorow aromatycznych (LC z detekcja fluorescencyjna) (WWA) chromatografia cieczowa z detekcja fluorescencyjna fluoranten  benzo[b]fluoranten  benzo[k]fluoranten  benzo[a]piren  benzo[g,h,i]perylen  indeno[1,2,3-c,d]piren  suma WWA (obliczeniowo z wartosci zmierzonych) Voda pitna, surova (povrchova, podzemni), uzitkova, odpadni, vodny vyluh kalu, sedimentu, shrabku, pisku, zeminy Stanoveni polyaromatickych uhlovodiku (LC s fluorescencni detekci) (PAU) LC s fluorescencni detekci fluoranten  benzo[b]fluoranten  benzo[k]fluoranten  benzo[a]pyren  benzo[g,h,i]perylen  indeno[c,d]pyren  suma PAU – vypoctem z namerenych hodnot SOP-O-32/analyty HPLC-32/PAU (CSN EN ISO 17993)","search_en":"Drinking water, raw water (surface, ground), service water, waste water, aqueous extract of sludge, sediment, screenings, sand, soil Determination of polycyclic aromatic hydrocarbons (LC with fluorescence detection) (PAH) LC with fluorescence detection fluoranthene  benzo[b]fluoranthene  benzo[k]fluoranthene  benzo[a]pyrene  benzo[g,h,i]perylene  indeno[1,2,3-c,d]pyrene  sum of PAH – by calculation from measured values SOP-O-32/analyty HPLC-32/PAU (ČSN EN ISO 17993)","search_zh":"饮用水、原水（地表水、地下水）、杂用水、废水、污泥、沉积物、栅渣、砂和土壤的水浸出液 多环芳烃的测定（液相色谱-荧光检测）（PAH） 液相色谱-荧光检测 荧蒽  苯并[b]荧蒽  苯并[k]荧蒽  苯并[a]芘  苯并[g,h,i]苝  茚并[1,2,3-c,d]芘  多环芳烃总和（由测量值计算） SOP-O-32/analyty HPLC-32/PAU (ČSN EN ISO 17993)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":24,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"c4a57b3b7d70efe2556a1b9d","lab_id":"69ad52a4de79e566650fd2e2","country":"CZ","accr_number":"1202","accr_body":"ČIA","row_label":"26","test_object":"Woda pitna, surowa (powierzchniowa, podziemna), użytkowa, ścieki, wyciąg wodny z osadu, osadu dennego, skratek, piasku, gruntu","test_object_en":"Drinking water, raw water (surface, ground), service water, waste water, aqueous extract of sludge, sediment, screenings, sand, soil","test_object_zh":"饮用水、原水（地表水、地下水）、杂用水、废水、污泥、沉积物、栅渣、砂和土壤的水浸出液","test_object_cs":"Voda pitná, surová (povrchová, podzemní), užitková, odpadní, vodný výluh kalu, sedimentu, shrabků, písku, zeminy","methodology":"Oznaczanie chlorków metodą miareczkową (Cl-)","methodology_en":"Determination of chloride by titration (Cl-)","methodology_zh":"滴定法测定氯化物（Cl-）","methodology_cs":"Stanovení chloridů titračně (Cl-)","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"metoda miareczkowa","technique_en":"by titration","technique_zh":"滴定法","technique_cs":"titračně","techniques":["metoda miareczkowa"],"techniques_en":["by titration"],"techniques_zh":["滴定法"],"techniques_cs":["titračně"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie chlorków metodą miareczkową (Cl-)\nmetoda miareczkowa","reference":"SOP-O-36/Cl- (M. Horáková, P. Lischke, A. Grunwald: „Chemické a fyzikální metody analýzy vod“, SNTL Praha, 1986, kap. 2.22.2)","norm_bases":["SOP-O-36/Cl-","M. Horáková, P. Lischke, A. Grunwald: „Chemické a fyzikální metody analýzy vod“, SNTL Praha, 1986, kap. 2.22.2"],"lab_section":"Laboratorium ścieków","lab_section_en":"Waste Water Laboratory","lab_section_zh":"废水实验室","lab_section_cs":"Laboratoř odpadních vod","lab_address":"Jateční 2581/40, 301 00 Plzeň","regulatory_area":"Laboratorium ścieków – Badania","regulatory_area_en":"Waste Water Laboratory – Tests","regulatory_area_zh":"废水实验室 – 检测","regulatory_area_cs":"Laboratoř odpadních vod – Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Woda pitna, surowa (powierzchniowa, podziemna), użytkowa, ścieki, wyciąg wodny z osadu, osadu dennego, skratek, piasku, gruntu Oznaczanie chlorków metodą miareczkową (Cl-) metoda miareczkowa Voda pitná, surová (povrchová, podzemní), užitková, odpadní, vodný výluh kalu, sedimentu, shrabků, písku, zeminy Stanovení chloridů titračně (Cl-) titračně SOP-O-36/Cl- (M. Horáková, P. Lischke, A. Grunwald: „Chemické a fyzikální metody analýzy vod“, SNTL Praha, 1986, kap. 2.22.2) Woda pitna, surowa (powierzchniowa, podziemna), uzytkowa, scieki, wyciag wodny z osadu, osadu dennego, skratek, piasku, gruntu Oznaczanie chlorkow metoda miareczkowa (Cl-) metoda miareczkowa Voda pitna, surova (povrchova, podzemni), uzitkova, odpadni, vodny vyluh kalu, sedimentu, shrabku, pisku, zeminy Stanoveni chloridu titracne (Cl-) titracne SOP-O-36/Cl- (M. Horakova, P. Lischke, A. Grunwald: „Chemicke a fyzikalni metody analyzy vod“, SNTL Praha, 1986, kap. 2.22.2)","search_en":"Drinking water, raw water (surface, ground), service water, waste water, aqueous extract of sludge, sediment, screenings, sand, soil Determination of chloride by titration (Cl-) by titration SOP-O-36/Cl- (M. Horáková, P. Lischke, A. Grunwald: „Chemické a fyzikální metody analýzy vod“, SNTL Praha, 1986, kap. 2.22.2)","search_zh":"饮用水、原水（地表水、地下水）、杂用水、废水、污泥、沉积物、栅渣、砂和土壤的水浸出液 滴定法测定氯化物（Cl-） 滴定法 SOP-O-36/Cl- (M. Horáková, P. Lischke, A. Grunwald: „Chemické a fyzikální metody analýzy vod“, SNTL Praha, 1986, kap. 2.22.2)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":25,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"2f534e110fcb757831d97ba7","lab_id":"69ad52a4de79e566650fd2e2","country":"CZ","accr_number":"1202","accr_body":"ČIA","row_label":"27","test_object":"Woda pitna, surowa (powierzchniowa, podziemna), użytkowa, ścieki, wyciąg wodny z osadu, osadu dennego, skratek, piasku, gruntu","test_object_en":"Drinking water, raw water (surface, ground), service water, waste water, aqueous extract of sludge, sediment, screenings, sand, soil","test_object_zh":"饮用水、原水（地表水、地下水）、杂用水、废水、污泥、沉积物、栅渣、砂和土壤的水浸出液","test_object_cs":"Voda pitná, surová (povrchová, podzemní), užitková, odpadní, vodný výluh kalu, sedimentu, shrabků, písku, zeminy","methodology":"Oznaczanie fenoli metodą fotometryczną (FN)","methodology_en":"Determination of phenols by photometry (FN)","methodology_zh":"光度法测定酚类（FN）","methodology_cs":"Stanovení fenolů fotometricky (FN)","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"metoda fotometryczna","technique_en":"by photometry","technique_zh":"光度法","technique_cs":"fotometricky","techniques":["metoda fotometryczna"],"techniques_en":["by photometry"],"techniques_zh":["光度法"],"techniques_cs":["fotometricky"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie fenoli metodą fotometryczną (FN)\nmetoda fotometryczna","reference":"SOP-O-39/FN (M. Horáková, P. Lischke, A. Grunwald: „Chemické a fyzikální metody analýzy vod“, SNTL Praha, 1986, kap. 2.41.2)","norm_bases":["SOP-O-39/FN","M. Horáková, P. Lischke, A. Grunwald: „Chemické a fyzikální metody analýzy vod“, SNTL Praha, 1986, kap. 2.41.2"],"lab_section":"Laboratorium ścieków","lab_section_en":"Waste Water Laboratory","lab_section_zh":"废水实验室","lab_section_cs":"Laboratoř odpadních vod","lab_address":"Jateční 2581/40, 301 00 Plzeň","regulatory_area":"Laboratorium ścieków – Badania","regulatory_area_en":"Waste Water Laboratory – Tests","regulatory_area_zh":"废水实验室 – 检测","regulatory_area_cs":"Laboratoř odpadních vod – Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Woda pitna, surowa (powierzchniowa, podziemna), użytkowa, ścieki, wyciąg wodny z osadu, osadu dennego, skratek, piasku, gruntu Oznaczanie fenoli metodą fotometryczną (FN) metoda fotometryczna Voda pitná, surová (povrchová, podzemní), užitková, odpadní, vodný výluh kalu, sedimentu, shrabků, písku, zeminy Stanovení fenolů fotometricky (FN) fotometricky SOP-O-39/FN (M. Horáková, P. Lischke, A. Grunwald: „Chemické a fyzikální metody analýzy vod“, SNTL Praha, 1986, kap. 2.41.2) Woda pitna, surowa (powierzchniowa, podziemna), uzytkowa, scieki, wyciag wodny z osadu, osadu dennego, skratek, piasku, gruntu Oznaczanie fenoli metoda fotometryczna (FN) metoda fotometryczna Voda pitna, surova (povrchova, podzemni), uzitkova, odpadni, vodny vyluh kalu, sedimentu, shrabku, pisku, zeminy Stanoveni fenolu fotometricky (FN) fotometricky SOP-O-39/FN (M. Horakova, P. Lischke, A. Grunwald: „Chemicke a fyzikalni metody analyzy vod“, SNTL Praha, 1986, kap. 2.41.2)","search_en":"Drinking water, raw water (surface, ground), service water, waste water, aqueous extract of sludge, sediment, screenings, sand, soil Determination of phenols by photometry (FN) by photometry SOP-O-39/FN (M. Horáková, P. Lischke, A. Grunwald: „Chemické a fyzikální metody analýzy vod“, SNTL Praha, 1986, kap. 2.41.2)","search_zh":"饮用水、原水（地表水、地下水）、杂用水、废水、污泥、沉积物、栅渣、砂和土壤的水浸出液 光度法测定酚类（FN） 光度法 SOP-O-39/FN (M. Horáková, P. Lischke, A. Grunwald: „Chemické a fyzikální metody analýzy vod“, SNTL Praha, 1986, kap. 2.41.2)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":26,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"e7b71680522a65ede420d389","lab_id":"69ad52a4de79e566650fd2e2","country":"CZ","accr_number":"1202","accr_body":"ČIA","row_label":"28","test_object":"Woda pitna, surowa (powierzchniowa, podziemna), użytkowa","test_object_en":"Drinking water, raw water (surface, ground), service water","test_object_zh":"饮用水、原水（地表水、地下水）、杂用水","test_object_cs":"Voda pitná, surová (povrchová, podzemní), užitková","methodology":"Oznaczanie metali metodą ICP/AES i twardości obliczeniowo z wartości zmierzonych","methodology_en":"Determination of metals by ICP/AES method and hardness by calculation from measured values","methodology_zh":"ICP/AES法测定金属并由测量值计算硬度","methodology_cs":"Stanovení kovů metodou ICP/AES a tvrdosti výpočtem z naměřených hodnot","parameters":[{"name":"Srebro (Ag)","range":""},{"name":"Glin (Al)","range":""},{"name":"Bor (B)","range":""},{"name":"Bar (Ba)","range":""},{"name":"Beryl (Be)","range":""},{"name":"Wapń (Ca)","range":""},{"name":"Kadm (Cd)","range":""},{"name":"Kobalt (Co)","range":""},{"name":"Chrom (Cr)","range":""},{"name":"Miedź (Cu)","range":""},{"name":"Żelazo (Fe)","range":""},{"name":"Potas (K)","range":""},{"name":"Magnez (Mg)","range":""},{"name":"Mangan (Mn)","range":""},{"name":"Molibden (Mo)","range":""},{"name":"Sód (Na)","range":""},{"name":"Nikiel (Ni)","range":""},{"name":"Fosfor (P)","range":""},{"name":"Ołów (Pb)","range":""},{"name":"Krzem (Si)","range":""},{"name":"Stront (Sr)","range":""},{"name":"Wanad (V)","range":""},{"name":"Cynk (Zn)","range":""}],"parameters_en":[{"name":"Silver (Ag)","range":""},{"name":"Aluminium (Al)","range":""},{"name":"Boron (B)","range":""},{"name":"Barium (Ba)","range":""},{"name":"Beryllium (Be)","range":""},{"name":"Calcium (Ca)","range":""},{"name":"Cadmium (Cd)","range":""},{"name":"Cobalt (Co)","range":""},{"name":"Chromium (Cr)","range":""},{"name":"Copper (Cu)","range":""},{"name":"Iron (Fe)","range":""},{"name":"Potassium (K)","range":""},{"name":"Magnesium (Mg)","range":""},{"name":"Manganese (Mn)","range":""},{"name":"Molybdenum (Mo)","range":""},{"name":"Sodium (Na)","range":""},{"name":"Nickel (Ni)","range":""},{"name":"Phosphorus (P)","range":""},{"name":"Lead (Pb)","range":""},{"name":"Silicon (Si)","range":""},{"name":"Strontium (Sr)","range":""},{"name":"Vanadium (V)","range":""},{"name":"Zinc (Zn)","range":""}],"parameters_zh":[{"name":"银（Ag）","range":""},{"name":"铝（Al）","range":""},{"name":"硼（B）","range":""},{"name":"钡（Ba）","range":""},{"name":"铍（Be）","range":""},{"name":"钙（Ca）","range":""},{"name":"镉（Cd）","range":""},{"name":"钴（Co）","range":""},{"name":"铬（Cr）","range":""},{"name":"铜（Cu）","range":""},{"name":"铁（Fe）","range":""},{"name":"钾（K）","range":""},{"name":"镁（Mg）","range":""},{"name":"锰（Mn）","range":""},{"name":"钼（Mo）","range":""},{"name":"钠（Na）","range":""},{"name":"镍（Ni）","range":""},{"name":"磷（P）","range":""},{"name":"铅（Pb）","range":""},{"name":"硅（Si）","range":""},{"name":"锶（Sr）","range":""},{"name":"钒（V）","range":""},{"name":"锌（Zn）","range":""}],"parameters_cs":[{"name":"Ag","range":""},{"name":"Al","range":""},{"name":"B","range":""},{"name":"Ba","range":""},{"name":"Be","range":""},{"name":"Ca","range":""},{"name":"Cd","range":""},{"name":"Co","range":""},{"name":"Cr","range":""},{"name":"Cu","range":""},{"name":"Fe","range":""},{"name":"K","range":""},{"name":"Mg","range":""},{"name":"Mn","range":""},{"name":"Mo","range":""},{"name":"Na","range":""},{"name":"Ni","range":""},{"name":"P","range":""},{"name":"Pb","range":""},{"name":"Si","range":""},{"name":"Sr","range":""},{"name":"V","range":""},{"name":"Zn","range":""}],"technique":"ICP-AES (ICP-OES)","technique_en":"ICP/AES method","technique_zh":"电感耦合等离子体原子发射光谱法（ICP/AES）","technique_cs":"metodou ICP/AES","techniques":["ICP-AES (ICP-OES)"],"techniques_en":["ICP/AES method"],"techniques_zh":["电感耦合等离子体原子发射光谱法（ICP/AES）"],"techniques_cs":["metodou ICP/AES"],"computed":["twardość (obliczeniowo z wartości zmierzonych)"],"computed_en":["hardness by calculation from measured values"],"computed_zh":["硬度（由测量值计算）"],"computed_cs":["tvrdosti výpočtem z naměřených hodnot"],"activity":"Oznaczanie metali metodą ICP/AES i twardości obliczeniowo z wartości zmierzonych\nZakres:\nSrebro (Ag)\nGlin (Al)\nBor (B)\nBar (Ba)\nBeryl (Be)\nWapń (Ca)\nKadm (Cd)\nKobalt (Co)\nChrom (Cr)\nMiedź (Cu)\nŻelazo (Fe)\nPotas (K)\nMagnez (Mg)\nMangan (Mn)\nMolibden (Mo)\nSód (Na)\nNikiel (Ni)\nFosfor (P)\nOłów (Pb)\nKrzem (Si)\nStront (Sr)\nWanad (V)\nCynk (Zn)\nICP-AES (ICP-OES)","reference":"SOP-O-74/kovy ICP AES - 74/kovy část A (ČSN EN ISO 11885)","norm_bases":["SOP-O-74/kovy ICP AES - 74/kovy část A","ČSN EN ISO 11885"],"lab_section":"Laboratorium ścieków","lab_section_en":"Waste Water Laboratory","lab_section_zh":"废水实验室","lab_section_cs":"Laboratoř odpadních vod","lab_address":"Jateční 2581/40, 301 00 Plzeň","regulatory_area":"Laboratorium ścieków – Badania","regulatory_area_en":"Waste Water Laboratory – Tests","regulatory_area_zh":"废水实验室 – 检测","regulatory_area_cs":"Laboratoř odpadních vod – Zkoušky","flexible":true,"flexibility":"B","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Woda pitna, surowa (powierzchniowa, podziemna), użytkowa Oznaczanie metali metodą ICP/AES i twardości obliczeniowo z wartości zmierzonych ICP-AES (ICP-OES) Srebro (Ag)  Glin (Al)  Bor (B)  Bar (Ba)  Beryl (Be)  Wapń (Ca)  Kadm (Cd)  Kobalt (Co)  Chrom (Cr)  Miedź (Cu)  Żelazo (Fe)  Potas (K)  Magnez (Mg)  Mangan (Mn)  Molibden (Mo)  Sód (Na)  Nikiel (Ni)  Fosfor (P)  Ołów (Pb)  Krzem (Si)  Stront (Sr)  Wanad (V)  Cynk (Zn)  twardość (obliczeniowo z wartości zmierzonych) Voda pitná, surová (povrchová, podzemní), užitková Stanovení kovů metodou ICP/AES a tvrdosti výpočtem z naměřených hodnot metodou ICP/AES Ag  Al  B  Ba  Be  Ca  Cd  Co  Cr  Cu  Fe  K  Mg  Mn  Mo  Na  Ni  P  Pb  Si  Sr  V  Zn  tvrdosti výpočtem z naměřených hodnot SOP-O-74/kovy ICP AES - 74/kovy část A (ČSN EN ISO 11885) Woda pitna, surowa (powierzchniowa, podziemna), uzytkowa Oznaczanie metali metoda ICP/AES i twardosci obliczeniowo z wartosci zmierzonych ICP-AES (ICP-OES) Srebro (Ag)  Glin (Al)  Bor (B)  Bar (Ba)  Beryl (Be)  Wapn (Ca)  Kadm (Cd)  Kobalt (Co)  Chrom (Cr)  Miedz (Cu)  Zelazo (Fe)  Potas (K)  Magnez (Mg)  Mangan (Mn)  Molibden (Mo)  Sod (Na)  Nikiel (Ni)  Fosfor (P)  Olow (Pb)  Krzem (Si)  Stront (Sr)  Wanad (V)  Cynk (Zn)  twardosc (obliczeniowo z wartosci zmierzonych) Voda pitna, surova (povrchova, podzemni), uzitkova Stanoveni kovu metodou ICP/AES a tvrdosti vypoctem z namerenych hodnot metodou ICP/AES Ag  Al  B  Ba  Be  Ca  Cd  Co  Cr  Cu  Fe  K  Mg  Mn  Mo  Na  Ni  P  Pb  Si  Sr  V  Zn  tvrdosti vypoctem z namerenych hodnot SOP-O-74/kovy ICP AES - 74/kovy cast A (CSN EN ISO 11885)","search_en":"Drinking water, raw water (surface, ground), service water Determination of metals by ICP/AES method and hardness by calculation from measured values ICP/AES method Silver (Ag)  Aluminium (Al)  Boron (B)  Barium (Ba)  Beryllium (Be)  Calcium (Ca)  Cadmium (Cd)  Cobalt (Co)  Chromium (Cr)  Copper (Cu)  Iron (Fe)  Potassium (K)  Magnesium (Mg)  Manganese (Mn)  Molybdenum (Mo)  Sodium (Na)  Nickel (Ni)  Phosphorus (P)  Lead (Pb)  Silicon (Si)  Strontium (Sr)  Vanadium (V)  Zinc (Zn)  hardness by calculation from measured values SOP-O-74/kovy ICP AES - 74/kovy část A (ČSN EN ISO 11885)","search_zh":"饮用水、原水（地表水、地下水）、杂用水 ICP/AES法测定金属并由测量值计算硬度 电感耦合等离子体原子发射光谱法（ICP/AES） 银（Ag）  铝（Al）  硼（B）  钡（Ba）  铍（Be）  钙（Ca）  镉（Cd）  钴（Co）  铬（Cr）  铜（Cu）  铁（Fe）  钾（K）  镁（Mg）  锰（Mn）  钼（Mo）  钠（Na）  镍（Ni）  磷（P）  铅（Pb）  硅（Si）  锶（Sr）  钒（V）  锌（Zn）  硬度（由测量值计算） SOP-O-74/kovy ICP AES - 74/kovy část A (ČSN EN ISO 11885)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":27,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"bc82416d57388ed40365b555","lab_id":"69ad52a4de79e566650fd2e2","country":"CZ","accr_number":"1202","accr_body":"ČIA","row_label":"29","test_object":"Ścieki, wyciąg wodny z osadu, osadu dennego, skratek, piasku, gruntu","test_object_en":"Waste water, aqueous extract of sludge, sediment, screenings, sand, soil","test_object_zh":"废水、污泥、沉积物、栅渣、砂和土壤的水浸出液","test_object_cs":"Voda odpadní, vodný výluh kalu, sedimentu, shrabků, písku, zeminy","methodology":"Oznaczanie metali metodą ICP/AES","methodology_en":"Determination of metals by ICP/AES method","methodology_zh":"ICP/AES法测定金属","methodology_cs":"Stanovení kovů metodou ICP/AES","parameters":[{"name":"Srebro (Ag)","range":""},{"name":"Glin (Al)","range":""},{"name":"Bor (B)","range":""},{"name":"Bar (Ba)","range":""},{"name":"Beryl (Be)","range":""},{"name":"Wapń (Ca)","range":""},{"name":"Kadm (Cd)","range":""},{"name":"Kobalt (Co)","range":""},{"name":"Chrom (Cr)","range":""},{"name":"Miedź (Cu)","range":""},{"name":"Żelazo (Fe)","range":""},{"name":"Potas (K)","range":""},{"name":"Magnez (Mg)","range":""},{"name":"Mangan (Mn)","range":""},{"name":"Molibden (Mo)","range":""},{"name":"Nikiel (Ni)","range":""},{"name":"Fosfor (P)","range":""},{"name":"Ołów (Pb)","range":""},{"name":"Wanad (V)","range":""},{"name":"Cynk (Zn)","range":""}],"parameters_en":[{"name":"Silver (Ag)","range":""},{"name":"Aluminium (Al)","range":""},{"name":"Boron (B)","range":""},{"name":"Barium (Ba)","range":""},{"name":"Beryllium (Be)","range":""},{"name":"Calcium (Ca)","range":""},{"name":"Cadmium (Cd)","range":""},{"name":"Cobalt (Co)","range":""},{"name":"Chromium (Cr)","range":""},{"name":"Copper (Cu)","range":""},{"name":"Iron (Fe)","range":""},{"name":"Potassium (K)","range":""},{"name":"Magnesium (Mg)","range":""},{"name":"Manganese (Mn)","range":""},{"name":"Molybdenum (Mo)","range":""},{"name":"Nickel (Ni)","range":""},{"name":"Phosphorus (P)","range":""},{"name":"Lead (Pb)","range":""},{"name":"Vanadium (V)","range":""},{"name":"Zinc (Zn)","range":""}],"parameters_zh":[{"name":"银（Ag）","range":""},{"name":"铝（Al）","range":""},{"name":"硼（B）","range":""},{"name":"钡（Ba）","range":""},{"name":"铍（Be）","range":""},{"name":"钙（Ca）","range":""},{"name":"镉（Cd）","range":""},{"name":"钴（Co）","range":""},{"name":"铬（Cr）","range":""},{"name":"铜（Cu）","range":""},{"name":"铁（Fe）","range":""},{"name":"钾（K）","range":""},{"name":"镁（Mg）","range":""},{"name":"锰（Mn）","range":""},{"name":"钼（Mo）","range":""},{"name":"镍（Ni）","range":""},{"name":"磷（P）","range":""},{"name":"铅（Pb）","range":""},{"name":"钒（V）","range":""},{"name":"锌（Zn）","range":""}],"parameters_cs":[{"name":"Ag","range":""},{"name":"Al","range":""},{"name":"B","range":""},{"name":"Ba","range":""},{"name":"Be","range":""},{"name":"Ca","range":""},{"name":"Cd","range":""},{"name":"Co","range":""},{"name":"Cr","range":""},{"name":"Cu","range":""},{"name":"Fe","range":""},{"name":"K","range":""},{"name":"Mg","range":""},{"name":"Mn","range":""},{"name":"Mo","range":""},{"name":"Ni","range":""},{"name":"P","range":""},{"name":"Pb","range":""},{"name":"V","range":""},{"name":"Zn","range":""}],"technique":"ICP-AES (ICP-OES)","technique_en":"ICP/AES method","technique_zh":"电感耦合等离子体原子发射光谱法（ICP/AES）","technique_cs":"metodou ICP/AES","techniques":["ICP-AES (ICP-OES)"],"techniques_en":["ICP/AES method"],"techniques_zh":["电感耦合等离子体原子发射光谱法（ICP/AES）"],"techniques_cs":["metodou ICP/AES"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie metali metodą ICP/AES\nZakres:\nSrebro (Ag)\nGlin (Al)\nBor (B)\nBar (Ba)\nBeryl (Be)\nWapń (Ca)\nKadm (Cd)\nKobalt (Co)\nChrom (Cr)\nMiedź (Cu)\nŻelazo (Fe)\nPotas (K)\nMagnez (Mg)\nMangan (Mn)\nMolibden (Mo)\nNikiel (Ni)\nFosfor (P)\nOłów (Pb)\nWanad (V)\nCynk (Zn)\nICP-AES (ICP-OES)","reference":"SOP-O-74/kovy ICP AES - 74/kovy část B (ČSN EN ISO 11885)","norm_bases":["SOP-O-74/kovy ICP AES - 74/kovy část B","ČSN EN ISO 11885"],"lab_section":"Laboratorium ścieków","lab_section_en":"Waste Water Laboratory","lab_section_zh":"废水实验室","lab_section_cs":"Laboratoř odpadních vod","lab_address":"Jateční 2581/40, 301 00 Plzeň","regulatory_area":"Laboratorium ścieków – Badania","regulatory_area_en":"Waste Water Laboratory – Tests","regulatory_area_zh":"废水实验室 – 检测","regulatory_area_cs":"Laboratoř odpadních vod – Zkoušky","flexible":true,"flexibility":"B","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Ścieki, wyciąg wodny z osadu, osadu dennego, skratek, piasku, gruntu Oznaczanie metali metodą ICP/AES ICP-AES (ICP-OES) Srebro (Ag)  Glin (Al)  Bor (B)  Bar (Ba)  Beryl (Be)  Wapń (Ca)  Kadm (Cd)  Kobalt (Co)  Chrom (Cr)  Miedź (Cu)  Żelazo (Fe)  Potas (K)  Magnez (Mg)  Mangan (Mn)  Molibden (Mo)  Nikiel (Ni)  Fosfor (P)  Ołów (Pb)  Wanad (V)  Cynk (Zn)  Voda odpadní, vodný výluh kalu, sedimentu, shrabků, písku, zeminy Stanovení kovů metodou ICP/AES metodou ICP/AES Ag  Al  B  Ba  Be  Ca  Cd  Co  Cr  Cu  Fe  K  Mg  Mn  Mo  Ni  P  Pb  V  Zn  SOP-O-74/kovy ICP AES - 74/kovy část B (ČSN EN ISO 11885) Scieki, wyciag wodny z osadu, osadu dennego, skratek, piasku, gruntu Oznaczanie metali metoda ICP/AES ICP-AES (ICP-OES) Srebro (Ag)  Glin (Al)  Bor (B)  Bar (Ba)  Beryl (Be)  Wapn (Ca)  Kadm (Cd)  Kobalt (Co)  Chrom (Cr)  Miedz (Cu)  Zelazo (Fe)  Potas (K)  Magnez (Mg)  Mangan (Mn)  Molibden (Mo)  Nikiel (Ni)  Fosfor (P)  Olow (Pb)  Wanad (V)  Cynk (Zn)  Voda odpadni, vodny vyluh kalu, sedimentu, shrabku, pisku, zeminy Stanoveni kovu metodou ICP/AES metodou ICP/AES Ag  Al  B  Ba  Be  Ca  Cd  Co  Cr  Cu  Fe  K  Mg  Mn  Mo  Ni  P  Pb  V  Zn  SOP-O-74/kovy ICP AES - 74/kovy cast B (CSN EN ISO 11885)","search_en":"Waste water, aqueous extract of sludge, sediment, screenings, sand, soil Determination of metals by ICP/AES method ICP/AES method Silver (Ag)  Aluminium (Al)  Boron (B)  Barium (Ba)  Beryllium (Be)  Calcium (Ca)  Cadmium (Cd)  Cobalt (Co)  Chromium (Cr)  Copper (Cu)  Iron (Fe)  Potassium (K)  Magnesium (Mg)  Manganese (Mn)  Molybdenum (Mo)  Nickel (Ni)  Phosphorus (P)  Lead (Pb)  Vanadium (V)  Zinc (Zn)  SOP-O-74/kovy ICP AES - 74/kovy část B (ČSN EN ISO 11885)","search_zh":"废水、污泥、沉积物、栅渣、砂和土壤的水浸出液 ICP/AES法测定金属 电感耦合等离子体原子发射光谱法（ICP/AES） 银（Ag）  铝（Al）  硼（B）  钡（Ba）  铍（Be）  钙（Ca）  镉（Cd）  钴（Co）  铬（Cr）  铜（Cu）  铁（Fe）  钾（K）  镁（Mg）  锰（Mn）  钼（Mo）  镍（Ni）  磷（P）  铅（Pb）  钒（V）  锌（Zn）  SOP-O-74/kovy ICP AES - 74/kovy část B (ČSN EN ISO 11885)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":28,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"ce0e73aa998eb8ffe631a3df","lab_id":"69ad52a4de79e566650fd2e2","country":"CZ","accr_number":"1202","accr_body":"ČIA","row_label":"30","test_object":"Osad, osad denny, skratki, piasek, grunt","test_object_en":"Sludge, sediment, screenings, sand, soil","test_object_zh":"污泥、沉积物、栅渣、砂、土壤","test_object_cs":"Kal, sediment, shrabky, písek, zemina","methodology":"Oznaczanie metali metodą ICP/AES","methodology_en":"Determination of metals by ICP/AES method","methodology_zh":"ICP/AES法测定金属","methodology_cs":"Stanovení kovů metodou ICP/AES","parameters":[{"name":"Srebro (Ag)","range":""},{"name":"Glin (Al)","range":""},{"name":"Bor (B)","range":""},{"name":"Bar (Ba)","range":""},{"name":"Beryl (Be)","range":""},{"name":"Wapń (Ca)","range":""},{"name":"Kadm (Cd)","range":""},{"name":"Kobalt (Co)","range":""},{"name":"Chrom (Cr)","range":""},{"name":"Miedź (Cu)","range":""},{"name":"Żelazo (Fe)","range":""},{"name":"Potas (K)","range":""},{"name":"Magnez (Mg)","range":""},{"name":"Mangan (Mn)","range":""},{"name":"Molibden (Mo)","range":""},{"name":"Nikiel (Ni)","range":""},{"name":"Fosfor (P)","range":""},{"name":"Ołów (Pb)","range":""},{"name":"Wanad (V)","range":""},{"name":"Cynk (Zn)","range":""}],"parameters_en":[{"name":"Silver (Ag)","range":""},{"name":"Aluminium (Al)","range":""},{"name":"Boron (B)","range":""},{"name":"Barium (Ba)","range":""},{"name":"Beryllium (Be)","range":""},{"name":"Calcium (Ca)","range":""},{"name":"Cadmium (Cd)","range":""},{"name":"Cobalt (Co)","range":""},{"name":"Chromium (Cr)","range":""},{"name":"Copper (Cu)","range":""},{"name":"Iron (Fe)","range":""},{"name":"Potassium (K)","range":""},{"name":"Magnesium (Mg)","range":""},{"name":"Manganese (Mn)","range":""},{"name":"Molybdenum (Mo)","range":""},{"name":"Nickel (Ni)","range":""},{"name":"Phosphorus (P)","range":""},{"name":"Lead (Pb)","range":""},{"name":"Vanadium (V)","range":""},{"name":"Zinc (Zn)","range":""}],"parameters_zh":[{"name":"银（Ag）","range":""},{"name":"铝（Al）","range":""},{"name":"硼（B）","range":""},{"name":"钡（Ba）","range":""},{"name":"铍（Be）","range":""},{"name":"钙（Ca）","range":""},{"name":"镉（Cd）","range":""},{"name":"钴（Co）","range":""},{"name":"铬（Cr）","range":""},{"name":"铜（Cu）","range":""},{"name":"铁（Fe）","range":""},{"name":"钾（K）","range":""},{"name":"镁（Mg）","range":""},{"name":"锰（Mn）","range":""},{"name":"钼（Mo）","range":""},{"name":"镍（Ni）","range":""},{"name":"磷（P）","range":""},{"name":"铅（Pb）","range":""},{"name":"钒（V）","range":""},{"name":"锌（Zn）","range":""}],"parameters_cs":[{"name":"Ag","range":""},{"name":"Al","range":""},{"name":"B","range":""},{"name":"Ba","range":""},{"name":"Be","range":""},{"name":"Ca","range":""},{"name":"Cd","range":""},{"name":"Co","range":""},{"name":"Cr","range":""},{"name":"Cu","range":""},{"name":"Fe","range":""},{"name":"K","range":""},{"name":"Mg","range":""},{"name":"Mn","range":""},{"name":"Mo","range":""},{"name":"Ni","range":""},{"name":"P","range":""},{"name":"Pb","range":""},{"name":"V","range":""},{"name":"Zn","range":""}],"technique":"ICP-AES (ICP-OES)","technique_en":"ICP/AES method","technique_zh":"电感耦合等离子体原子发射光谱法（ICP/AES）","technique_cs":"metodou ICP/AES","techniques":["ICP-AES (ICP-OES)"],"techniques_en":["ICP/AES method"],"techniques_zh":["电感耦合等离子体原子发射光谱法（ICP/AES）"],"techniques_cs":["metodou ICP/AES"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie metali metodą ICP/AES\nZakres:\nSrebro (Ag)\nGlin (Al)\nBor (B)\nBar (Ba)\nBeryl (Be)\nWapń (Ca)\nKadm (Cd)\nKobalt (Co)\nChrom (Cr)\nMiedź (Cu)\nŻelazo (Fe)\nPotas (K)\nMagnez (Mg)\nMangan (Mn)\nMolibden (Mo)\nNikiel (Ni)\nFosfor (P)\nOłów (Pb)\nWanad (V)\nCynk (Zn)\nICP-AES (ICP-OES)","reference":"SOP-O-74/kovy ICP AES - 74/kovy část C (ČSN EN ISO 11885; ČSN EN 16173; ČSN EN 16170; ČSN EN ISO 54321)","norm_bases":["SOP-O-74/kovy ICP AES - 74/kovy část C","ČSN EN ISO 11885","ČSN EN 16173","ČSN EN 16170","ČSN EN ISO 54321"],"lab_section":"Laboratorium ścieków","lab_section_en":"Waste Water Laboratory","lab_section_zh":"废水实验室","lab_section_cs":"Laboratoř odpadních vod","lab_address":"Jateční 2581/40, 301 00 Plzeň","regulatory_area":"Laboratorium ścieków – Badania","regulatory_area_en":"Waste Water Laboratory – Tests","regulatory_area_zh":"废水实验室 – 检测","regulatory_area_cs":"Laboratoř odpadních vod – Zkoušky","flexible":true,"flexibility":"A, B","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Osad, osad denny, skratki, piasek, grunt Oznaczanie metali metodą ICP/AES ICP-AES (ICP-OES) Srebro (Ag)  Glin (Al)  Bor (B)  Bar (Ba)  Beryl (Be)  Wapń (Ca)  Kadm (Cd)  Kobalt (Co)  Chrom (Cr)  Miedź (Cu)  Żelazo (Fe)  Potas (K)  Magnez (Mg)  Mangan (Mn)  Molibden (Mo)  Nikiel (Ni)  Fosfor (P)  Ołów (Pb)  Wanad (V)  Cynk (Zn)  Kal, sediment, shrabky, písek, zemina Stanovení kovů metodou ICP/AES metodou ICP/AES Ag  Al  B  Ba  Be  Ca  Cd  Co  Cr  Cu  Fe  K  Mg  Mn  Mo  Ni  P  Pb  V  Zn  SOP-O-74/kovy ICP AES - 74/kovy část C (ČSN EN ISO 11885; ČSN EN 16173; ČSN EN 16170; ČSN EN ISO 54321) Osad, osad denny, skratki, piasek, grunt Oznaczanie metali metoda ICP/AES ICP-AES (ICP-OES) Srebro (Ag)  Glin (Al)  Bor (B)  Bar (Ba)  Beryl (Be)  Wapn (Ca)  Kadm (Cd)  Kobalt (Co)  Chrom (Cr)  Miedz (Cu)  Zelazo (Fe)  Potas (K)  Magnez (Mg)  Mangan (Mn)  Molibden (Mo)  Nikiel (Ni)  Fosfor (P)  Olow (Pb)  Wanad (V)  Cynk (Zn)  Kal, sediment, shrabky, pisek, zemina Stanoveni kovu metodou ICP/AES metodou ICP/AES Ag  Al  B  Ba  Be  Ca  Cd  Co  Cr  Cu  Fe  K  Mg  Mn  Mo  Ni  P  Pb  V  Zn  SOP-O-74/kovy ICP AES - 74/kovy cast C (CSN EN ISO 11885; CSN EN 16173; CSN EN 16170; CSN EN ISO 54321)","search_en":"Sludge, sediment, screenings, sand, soil Determination of metals by ICP/AES method ICP/AES method Silver (Ag)  Aluminium (Al)  Boron (B)  Barium (Ba)  Beryllium (Be)  Calcium (Ca)  Cadmium (Cd)  Cobalt (Co)  Chromium (Cr)  Copper (Cu)  Iron (Fe)  Potassium (K)  Magnesium (Mg)  Manganese (Mn)  Molybdenum (Mo)  Nickel (Ni)  Phosphorus (P)  Lead (Pb)  Vanadium (V)  Zinc (Zn)  SOP-O-74/kovy ICP AES - 74/kovy část C (ČSN EN ISO 11885; ČSN EN 16173; ČSN EN 16170; ČSN EN ISO 54321)","search_zh":"污泥、沉积物、栅渣、砂、土壤 ICP/AES法测定金属 电感耦合等离子体原子发射光谱法（ICP/AES） 银（Ag）  铝（Al）  硼（B）  钡（Ba）  铍（Be）  钙（Ca）  镉（Cd）  钴（Co）  铬（Cr）  铜（Cu）  铁（Fe）  钾（K）  镁（Mg）  锰（Mn）  钼（Mo）  镍（Ni）  磷（P）  铅（Pb）  钒（V）  锌（Zn）  SOP-O-74/kovy ICP AES - 74/kovy část C (ČSN EN ISO 11885; ČSN EN 16173; ČSN EN 16170; ČSN EN ISO 54321)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":29,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"3a91c748ac1b6f82e3c434d8","lab_id":"69ad52a4de79e566650fd2e2","country":"CZ","accr_number":"1202","accr_body":"ČIA","row_label":"31","test_object":"Woda pitna, surowa (powierzchniowa, podziemna), użytkowa","test_object_en":"Drinking water, raw water (surface, ground), service water","test_object_zh":"饮用水、原水（地表水、地下水）、杂用水","test_object_cs":"Voda pitná, surová (povrchová, podzemní), užitková","methodology":"Oznaczanie metali (As, Sb, Sn, Se) techniką wodorkową ICP/AES","methodology_en":"Determination of metals (As, Sb, Sn, Se) by hydride ICP/AES method","methodology_zh":"氢化物发生ICP/AES法测定金属（As、Sb、Sn、Se）","methodology_cs":"Stanovení kovů (As, Sb, Sn, Se) hydridovou metodou ICP/AES","parameters":[{"name":"Arsen (As)","range":""},{"name":"Antymon (Sb)","range":""},{"name":"Cyna (Sn)","range":""},{"name":"Selen (Se)","range":""}],"parameters_en":[{"name":"Arsenic (As)","range":""},{"name":"Antimony (Sb)","range":""},{"name":"Tin (Sn)","range":""},{"name":"Selenium (Se)","range":""}],"parameters_zh":[{"name":"砷（As）","range":""},{"name":"锑（Sb）","range":""},{"name":"锡（Sn）","range":""},{"name":"硒（Se）","range":""}],"parameters_cs":[{"name":"As","range":""},{"name":"Sb","range":""},{"name":"Sn","range":""},{"name":"Se","range":""}],"technique":"technika wodorkowa ICP/AES","technique_en":"hydride ICP/AES method","technique_zh":"氢化物发生ICP/AES法","technique_cs":"hydridovou metodou ICP/AES","techniques":["technika wodorkowa ICP/AES"],"techniques_en":["hydride ICP/AES method"],"techniques_zh":["氢化物发生ICP/AES法"],"techniques_cs":["hydridovou metodou ICP/AES"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie metali (As, Sb, Sn, Se) techniką wodorkową ICP/AES\nZakres:\nArsen (As)\nAntymon (Sb)\nCyna (Sn)\nSelen (Se)\ntechnika wodorkowa ICP/AES","reference":"SOP-O-74/kovy ICP AES - 74/kovy část D (ČSN EN ISO 11885)","norm_bases":["SOP-O-74/kovy ICP AES - 74/kovy část D","ČSN EN ISO 11885"],"lab_section":"Laboratorium ścieków","lab_section_en":"Waste Water Laboratory","lab_section_zh":"废水实验室","lab_section_cs":"Laboratoř odpadních vod","lab_address":"Jateční 2581/40, 301 00 Plzeň","regulatory_area":"Laboratorium ścieków – Badania","regulatory_area_en":"Waste Water Laboratory – Tests","regulatory_area_zh":"废水实验室 – 检测","regulatory_area_cs":"Laboratoř odpadních vod – Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Woda pitna, surowa (powierzchniowa, podziemna), użytkowa Oznaczanie metali (As, Sb, Sn, Se) techniką wodorkową ICP/AES technika wodorkowa ICP/AES Arsen (As)  Antymon (Sb)  Cyna (Sn)  Selen (Se)  Voda pitná, surová (povrchová, podzemní), užitková Stanovení kovů (As, Sb, Sn, Se) hydridovou metodou ICP/AES hydridovou metodou ICP/AES As  Sb  Sn  Se  SOP-O-74/kovy ICP AES - 74/kovy část D (ČSN EN ISO 11885) Woda pitna, surowa (powierzchniowa, podziemna), uzytkowa Oznaczanie metali (As, Sb, Sn, Se) technika wodorkowa ICP/AES technika wodorkowa ICP/AES Arsen (As)  Antymon (Sb)  Cyna (Sn)  Selen (Se)  Voda pitna, surova (povrchova, podzemni), uzitkova Stanoveni kovu (As, Sb, Sn, Se) hydridovou metodou ICP/AES hydridovou metodou ICP/AES As  Sb  Sn  Se  SOP-O-74/kovy ICP AES - 74/kovy cast D (CSN EN ISO 11885)","search_en":"Drinking water, raw water (surface, ground), service water Determination of metals (As, Sb, Sn, Se) by hydride ICP/AES method hydride ICP/AES method Arsenic (As)  Antimony (Sb)  Tin (Sn)  Selenium (Se)  SOP-O-74/kovy ICP AES - 74/kovy část D (ČSN EN ISO 11885)","search_zh":"饮用水、原水（地表水、地下水）、杂用水 氢化物发生ICP/AES法测定金属（As、Sb、Sn、Se） 氢化物发生ICP/AES法 砷（As）  锑（Sb）  锡（Sn）  硒（Se）  SOP-O-74/kovy ICP AES - 74/kovy část D (ČSN EN ISO 11885)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":30,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"49ea7a40f6fce7106ca71e11","lab_id":"69ad52a4de79e566650fd2e2","country":"CZ","accr_number":"1202","accr_body":"ČIA","row_label":"32","test_object":"Ścieki, wyciąg wodny z osadu, osadu dennego, skratek, piasku, gruntu","test_object_en":"Waste water, aqueous extract of sludge, sediment, screenings, sand, soil","test_object_zh":"废水、污泥、沉积物、栅渣、砂和土壤的水浸出液","test_object_cs":"Voda odpadní, vodný výluh kalu, sedimentu, shrabků, písku, zeminy","methodology":"Oznaczanie metali (As, Sb, Sn, Se) techniką wodorkową ICP/AES","methodology_en":"Determination of metals (As, Sb, Sn, Se) by hydride ICP/AES method","methodology_zh":"氢化物发生ICP/AES法测定金属（As、Sb、Sn、Se）","methodology_cs":"Stanovení kovů (As, Sb, Sn, Se) hydridovou metodou ICP/AES","parameters":[{"name":"Arsen (As)","range":""},{"name":"Antymon (Sb)","range":""},{"name":"Cyna (Sn)","range":""},{"name":"Selen (Se)","range":""}],"parameters_en":[{"name":"Arsenic (As)","range":""},{"name":"Antimony (Sb)","range":""},{"name":"Tin (Sn)","range":""},{"name":"Selenium (Se)","range":""}],"parameters_zh":[{"name":"砷（As）","range":""},{"name":"锑（Sb）","range":""},{"name":"锡（Sn）","range":""},{"name":"硒（Se）","range":""}],"parameters_cs":[{"name":"As","range":""},{"name":"Sb","range":""},{"name":"Sn","range":""},{"name":"Se","range":""}],"technique":"technika wodorkowa ICP/AES","technique_en":"hydride ICP/AES method","technique_zh":"氢化物发生ICP/AES法","technique_cs":"hydridovou metodou ICP/AES","techniques":["technika wodorkowa ICP/AES"],"techniques_en":["hydride ICP/AES method"],"techniques_zh":["氢化物发生ICP/AES法"],"techniques_cs":["hydridovou metodou ICP/AES"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie metali (As, Sb, Sn, Se) techniką wodorkową ICP/AES\nZakres:\nArsen (As)\nAntymon (Sb)\nCyna (Sn)\nSelen (Se)\ntechnika wodorkowa ICP/AES","reference":"SOP-O-74/kovy ICP AES - 74/kovy část E (ČSN EN ISO 11885)","norm_bases":["SOP-O-74/kovy ICP AES - 74/kovy část E","ČSN EN ISO 11885"],"lab_section":"Laboratorium ścieków","lab_section_en":"Waste Water Laboratory","lab_section_zh":"废水实验室","lab_section_cs":"Laboratoř odpadních vod","lab_address":"Jateční 2581/40, 301 00 Plzeň","regulatory_area":"Laboratorium ścieków – Badania","regulatory_area_en":"Waste Water Laboratory – Tests","regulatory_area_zh":"废水实验室 – 检测","regulatory_area_cs":"Laboratoř odpadních vod – Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Ścieki, wyciąg wodny z osadu, osadu dennego, skratek, piasku, gruntu Oznaczanie metali (As, Sb, Sn, Se) techniką wodorkową ICP/AES technika wodorkowa ICP/AES Arsen (As)  Antymon (Sb)  Cyna (Sn)  Selen (Se)  Voda odpadní, vodný výluh kalu, sedimentu, shrabků, písku, zeminy Stanovení kovů (As, Sb, Sn, Se) hydridovou metodou ICP/AES hydridovou metodou ICP/AES As  Sb  Sn  Se  SOP-O-74/kovy ICP AES - 74/kovy část E (ČSN EN ISO 11885) Scieki, wyciag wodny z osadu, osadu dennego, skratek, piasku, gruntu Oznaczanie metali (As, Sb, Sn, Se) technika wodorkowa ICP/AES technika wodorkowa ICP/AES Arsen (As)  Antymon (Sb)  Cyna (Sn)  Selen (Se)  Voda odpadni, vodny vyluh kalu, sedimentu, shrabku, pisku, zeminy Stanoveni kovu (As, Sb, Sn, Se) hydridovou metodou ICP/AES hydridovou metodou ICP/AES As  Sb  Sn  Se  SOP-O-74/kovy ICP AES - 74/kovy cast E (CSN EN ISO 11885)","search_en":"Waste water, aqueous extract of sludge, sediment, screenings, sand, soil Determination of metals (As, Sb, Sn, Se) by hydride ICP/AES method hydride ICP/AES method Arsenic (As)  Antimony (Sb)  Tin (Sn)  Selenium (Se)  SOP-O-74/kovy ICP AES - 74/kovy část E (ČSN EN ISO 11885)","search_zh":"废水、污泥、沉积物、栅渣、砂和土壤的水浸出液 氢化物发生ICP/AES法测定金属（As、Sb、Sn、Se） 氢化物发生ICP/AES法 砷（As）  锑（Sb）  锡（Sn）  硒（Se）  SOP-O-74/kovy ICP AES - 74/kovy část E (ČSN EN ISO 11885)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":31,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"6ac63f789b5c30b734e866b9","lab_id":"69ad52a4de79e566650fd2e2","country":"CZ","accr_number":"1202","accr_body":"ČIA","row_label":"33","test_object":"Osad, osad denny, skratki, piasek, grunt","test_object_en":"Sludge, sediment, screenings, sand, soil","test_object_zh":"污泥、沉积物、栅渣、砂、土壤","test_object_cs":"Kal, sediment, shrabky, písek, zemina","methodology":"Oznaczanie metali (As, Sb, Sn, Se) techniką wodorkową ICP/AES","methodology_en":"Determination of metals (As, Sb, Sn, Se) by hydride ICP/AES method","methodology_zh":"氢化物发生ICP/AES法测定金属（As、Sb、Sn、Se）","methodology_cs":"Stanovení kovů (As, Sb, Sn, Se) hydridovou metodou ICP/AES","parameters":[{"name":"Arsen (As)","range":""},{"name":"Antymon (Sb)","range":""},{"name":"Cyna (Sn)","range":""},{"name":"Selen (Se)","range":""}],"parameters_en":[{"name":"Arsenic (As)","range":""},{"name":"Antimony (Sb)","range":""},{"name":"Tin (Sn)","range":""},{"name":"Selenium (Se)","range":""}],"parameters_zh":[{"name":"砷（As）","range":""},{"name":"锑（Sb）","range":""},{"name":"锡（Sn）","range":""},{"name":"硒（Se）","range":""}],"parameters_cs":[{"name":"As","range":""},{"name":"Sb","range":""},{"name":"Sn","range":""},{"name":"Se","range":""}],"technique":"technika wodorkowa ICP/AES","technique_en":"hydride ICP/AES method","technique_zh":"氢化物发生ICP/AES法","technique_cs":"hydridovou metodou ICP/AES","techniques":["technika wodorkowa ICP/AES"],"techniques_en":["hydride ICP/AES method"],"techniques_zh":["氢化物发生ICP/AES法"],"techniques_cs":["hydridovou metodou ICP/AES"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie metali (As, Sb, Sn, Se) techniką wodorkową ICP/AES\nZakres:\nArsen (As)\nAntymon (Sb)\nCyna (Sn)\nSelen (Se)\ntechnika wodorkowa ICP/AES","reference":"SOP-O-74/kovy ICP AES - 74/kovy část F (ČSN EN ISO 11885; ČSN EN 16173; ČSN EN 16170; ČSN EN ISO 54321)","norm_bases":["SOP-O-74/kovy ICP AES - 74/kovy část F","ČSN EN ISO 11885","ČSN EN 16173","ČSN EN 16170","ČSN EN ISO 54321"],"lab_section":"Laboratorium ścieków","lab_section_en":"Waste Water Laboratory","lab_section_zh":"废水实验室","lab_section_cs":"Laboratoř odpadních vod","lab_address":"Jateční 2581/40, 301 00 Plzeň","regulatory_area":"Laboratorium ścieków – Badania","regulatory_area_en":"Waste Water Laboratory – Tests","regulatory_area_zh":"废水实验室 – 检测","regulatory_area_cs":"Laboratoř odpadních vod – Zkoušky","flexible":true,"flexibility":"A","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Osad, osad denny, skratki, piasek, grunt Oznaczanie metali (As, Sb, Sn, Se) techniką wodorkową ICP/AES technika wodorkowa ICP/AES Arsen (As)  Antymon (Sb)  Cyna (Sn)  Selen (Se)  Kal, sediment, shrabky, písek, zemina Stanovení kovů (As, Sb, Sn, Se) hydridovou metodou ICP/AES hydridovou metodou ICP/AES As  Sb  Sn  Se  SOP-O-74/kovy ICP AES - 74/kovy část F (ČSN EN ISO 11885; ČSN EN 16173; ČSN EN 16170; ČSN EN ISO 54321) Osad, osad denny, skratki, piasek, grunt Oznaczanie metali (As, Sb, Sn, Se) technika wodorkowa ICP/AES technika wodorkowa ICP/AES Arsen (As)  Antymon (Sb)  Cyna (Sn)  Selen (Se)  Kal, sediment, shrabky, pisek, zemina Stanoveni kovu (As, Sb, Sn, Se) hydridovou metodou ICP/AES hydridovou metodou ICP/AES As  Sb  Sn  Se  SOP-O-74/kovy ICP AES - 74/kovy cast F (CSN EN ISO 11885; CSN EN 16173; CSN EN 16170; CSN EN ISO 54321)","search_en":"Sludge, sediment, screenings, sand, soil Determination of metals (As, Sb, Sn, Se) by hydride ICP/AES method hydride ICP/AES method Arsenic (As)  Antimony (Sb)  Tin (Sn)  Selenium (Se)  SOP-O-74/kovy ICP AES - 74/kovy část F (ČSN EN ISO 11885; ČSN EN 16173; ČSN EN 16170; ČSN EN ISO 54321)","search_zh":"污泥、沉积物、栅渣、砂、土壤 氢化物发生ICP/AES法测定金属（As、Sb、Sn、Se） 氢化物发生ICP/AES法 砷（As）  锑（Sb）  锡（Sn）  硒（Se）  SOP-O-74/kovy ICP AES - 74/kovy část F (ČSN EN ISO 11885; ČSN EN 16173; ČSN EN 16170; ČSN EN ISO 54321)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":32,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"f75d3e9b0bbda6b5cc0ff53a","lab_id":"69ad52a4de79e566650fd2e2","country":"CZ","accr_number":"1202","accr_body":"ČIA","row_label":"34","test_object":"Woda pitna, surowa (powierzchniowa, podziemna), użytkowa, ścieki, wyciąg wodny z osadu, osadu dennego, skratek, piasku, gruntu, osad, osad denny, skratki, piasek, grunt","test_object_en":"Drinking water, raw water (surface, ground), service water, waste water, aqueous extract of sludge, sediment, screenings, sand, soil, sludge, sediment, screenings, sand, soil","test_object_zh":"饮用水、原水（地表水、地下水）、杂用水、废水、污泥/沉积物/栅渣/砂/土壤的水浸出液，以及污泥、沉积物、栅渣、砂、土壤","test_object_cs":"Voda pitná, surová (povrchová, podzemní), užitková, odpadní, vodný výluh kalu, sedimentu, shrabků, písku, zeminy, kal, sediment, shrabky, písek, zemina","methodology":"Oznaczanie rtęci metodą spektrofotometryczną (Hg)","methodology_en":"Determination of mercury by spectrophotometry (Hg)","methodology_zh":"分光光度法测定汞（Hg）","methodology_cs":"Stanovení rtuti spektrofotometricky (Hg)","parameters":[{"name":"Rtęć (Hg)","range":""}],"parameters_en":[{"name":"Mercury (Hg)","range":""}],"parameters_zh":[{"name":"汞（Hg）","range":""}],"parameters_cs":[{"name":"Hg","range":""}],"technique":"metoda spektrofotometryczna (AMA)","technique_en":"by spectrophotometry","technique_zh":"分光光度法","technique_cs":"spektrofotometricky","techniques":["metoda spektrofotometryczna (AMA)"],"techniques_en":["by spectrophotometry"],"techniques_zh":["分光光度法"],"techniques_cs":["spektrofotometricky"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie rtęci metodą spektrofotometryczną (Hg)\nRtęć (Hg)\nmetoda spektrofotometryczna (AMA)","reference":"SOP-O-76/Hg (ČSN 75 7440; EPA Method 7473; ČSN EN 16173)","norm_bases":["SOP-O-76/Hg","ČSN 75 7440","EPA Method 7473","ČSN EN 16173"],"lab_section":"Laboratorium ścieków","lab_section_en":"Waste Water Laboratory","lab_section_zh":"废水实验室","lab_section_cs":"Laboratoř odpadních vod","lab_address":"Jateční 2581/40, 301 00 Plzeň","regulatory_area":"Laboratorium ścieków – Badania","regulatory_area_en":"Waste Water Laboratory – Tests","regulatory_area_zh":"废水实验室 – 检测","regulatory_area_cs":"Laboratoř odpadních vod – Zkoušky","flexible":true,"flexibility":"A","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Woda pitna, surowa (powierzchniowa, podziemna), użytkowa, ścieki, wyciąg wodny z osadu, osadu dennego, skratek, piasku, gruntu, osad, osad denny, skratki, piasek, grunt Oznaczanie rtęci metodą spektrofotometryczną (Hg) metoda spektrofotometryczna (AMA) Rtęć (Hg)  Voda pitná, surová (povrchová, podzemní), užitková, odpadní, vodný výluh kalu, sedimentu, shrabků, písku, zeminy, kal, sediment, shrabky, písek, zemina Stanovení rtuti spektrofotometricky (Hg) spektrofotometricky Hg  SOP-O-76/Hg (ČSN 75 7440; EPA Method 7473; ČSN EN 16173) Woda pitna, surowa (powierzchniowa, podziemna), uzytkowa, scieki, wyciag wodny z osadu, osadu dennego, skratek, piasku, gruntu, osad, osad denny, skratki, piasek, grunt Oznaczanie rteci metoda spektrofotometryczna (Hg) metoda spektrofotometryczna (AMA) Rtec (Hg)  Voda pitna, surova (povrchova, podzemni), uzitkova, odpadni, vodny vyluh kalu, sedimentu, shrabku, pisku, zeminy, kal, sediment, shrabky, pisek, zemina Stanoveni rtuti spektrofotometricky (Hg) spektrofotometricky Hg  SOP-O-76/Hg (CSN 75 7440; EPA Method 7473; CSN EN 16173)","search_en":"Drinking water, raw water (surface, ground), service water, waste water, aqueous extract of sludge, sediment, screenings, sand, soil, sludge, sediment, screenings, sand, soil Determination of mercury by spectrophotometry (Hg) by spectrophotometry Mercury (Hg)  SOP-O-76/Hg (ČSN 75 7440; EPA Method 7473; ČSN EN 16173)","search_zh":"饮用水、原水（地表水、地下水）、杂用水、废水、污泥/沉积物/栅渣/砂/土壤的水浸出液，以及污泥、沉积物、栅渣、砂、土壤 分光光度法测定汞（Hg） 分光光度法 汞（Hg）  SOP-O-76/Hg (ČSN 75 7440; EPA Method 7473; ČSN EN 16173)","categories":["water","environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":33,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"091702452f9ca445a8d14521","lab_id":"69ad52a4de79e566650fd2e2","country":"CZ","accr_number":"1202","accr_body":"ČIA","row_label":"35","test_object":"Woda pitna, surowa (powierzchniowa, podziemna), użytkowa, ścieki, wyciąg wodny z osadu, osadu dennego, skratek, piasku, gruntu","test_object_en":"Drinking water, raw water (surface, ground), service water, waste water, aqueous extract of sludge, sediment, screenings, sand, soil","test_object_zh":"饮用水、原水（地表水、地下水）、杂用水、废水、污泥、沉积物、栅渣、砂和土壤的水浸出液","test_object_cs":"Voda pitná, surová (povrchová, podzemní), užitková, odpadní, vodný výluh kalu, sedimentu, shrabků, písku, zeminy","methodology":"Oznaczanie azotu ogólnego za pomocą analizatora TN (N og.)","methodology_en":"Determination of total nitrogen using a TN analyser (N tot.)","methodology_zh":"总氮分析仪测定总氮","methodology_cs":"Stanovení dusíku celkového pomocí analyzátoru TN (N cel.)","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"analizator azotu ogólnego (TN)","technique_en":"TN analyser","technique_zh":"总氮分析仪","technique_cs":"pomocí analyzátoru TN","techniques":["analizator azotu ogólnego (TN)"],"techniques_en":["TN analyser"],"techniques_zh":["总氮分析仪"],"techniques_cs":["pomocí analyzátoru TN"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie azotu ogólnego za pomocą analizatora TN (N og.)\nanalizator azotu ogólnego (TN)","reference":"SOP-O-67/C, 25/N cel. část A (ČSN EN ISO 20236)","norm_bases":["SOP-O-67/C, 25/N cel. část A","ČSN EN ISO 20236"],"lab_section":"Laboratorium ścieków","lab_section_en":"Waste Water Laboratory","lab_section_zh":"废水实验室","lab_section_cs":"Laboratoř odpadních vod","lab_address":"Jateční 2581/40, 301 00 Plzeň","regulatory_area":"Laboratorium ścieków – Badania","regulatory_area_en":"Waste Water Laboratory – Tests","regulatory_area_zh":"废水实验室 – 检测","regulatory_area_cs":"Laboratoř odpadních vod – Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Woda pitna, surowa (powierzchniowa, podziemna), użytkowa, ścieki, wyciąg wodny z osadu, osadu dennego, skratek, piasku, gruntu Oznaczanie azotu ogólnego za pomocą analizatora TN (N og.) analizator azotu ogólnego (TN) Voda pitná, surová (povrchová, podzemní), užitková, odpadní, vodný výluh kalu, sedimentu, shrabků, písku, zeminy Stanovení dusíku celkového pomocí analyzátoru TN (N cel.) pomocí analyzátoru TN SOP-O-67/C, 25/N cel. část A (ČSN EN ISO 20236) Woda pitna, surowa (powierzchniowa, podziemna), uzytkowa, scieki, wyciag wodny z osadu, osadu dennego, skratek, piasku, gruntu Oznaczanie azotu ogolnego za pomoca analizatora TN (N og.) analizator azotu ogolnego (TN) Voda pitna, surova (povrchova, podzemni), uzitkova, odpadni, vodny vyluh kalu, sedimentu, shrabku, pisku, zeminy Stanoveni dusiku celkoveho pomoci analyzatoru TN (N cel.) pomoci analyzatoru TN SOP-O-67/C, 25/N cel. cast A (CSN EN ISO 20236)","search_en":"Drinking water, raw water (surface, ground), service water, waste water, aqueous extract of sludge, sediment, screenings, sand, soil Determination of total nitrogen using a TN analyser (N tot.) TN analyser SOP-O-67/C, 25/N cel. část A (ČSN EN ISO 20236)","search_zh":"饮用水、原水（地表水、地下水）、杂用水、废水、污泥、沉积物、栅渣、砂和土壤的水浸出液 总氮分析仪测定总氮 总氮分析仪 SOP-O-67/C, 25/N cel. část A (ČSN EN ISO 20236)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":34,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"8dcc3999844bc9ac0785cbcc","lab_id":"69ad52a4de79e566650fd2e2","country":"CZ","accr_number":"1202","accr_body":"ČIA","row_label":"36","test_object":"Osad, osad denny, skratki, piasek, grunt","test_object_en":"Sludge, sediment, screenings, sand, soil","test_object_zh":"污泥、沉积物、栅渣、砂、土壤","test_object_cs":"Kal, sediment, shrabky, písek, zemina","methodology":"Oznaczanie azotu ogólnego za pomocą analizatora TN (N og.)","methodology_en":"Determination of total nitrogen using a TN analyser (N tot.)","methodology_zh":"总氮分析仪测定总氮","methodology_cs":"Stanovení dusíku celkového pomocí analyzátoru TN (N cel.)","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"analizator azotu ogólnego (TN)","technique_en":"TN analyser","technique_zh":"总氮分析仪","technique_cs":"pomocí analyzátoru TN","techniques":["analizator azotu ogólnego (TN)"],"techniques_en":["TN analyser"],"techniques_zh":["总氮分析仪"],"techniques_cs":["pomocí analyzátoru TN"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie azotu ogólnego za pomocą analizatora TN (N og.)\nanalizator azotu ogólnego (TN)","reference":"SOP-O-67/C, 25/N cel. Část B (ČSN EN ISO 20236)","norm_bases":["SOP-O-67/C, 25/N cel. Část B","ČSN EN ISO 20236"],"lab_section":"Laboratorium ścieków","lab_section_en":"Waste Water Laboratory","lab_section_zh":"废水实验室","lab_section_cs":"Laboratoř odpadních vod","lab_address":"Jateční 2581/40, 301 00 Plzeň","regulatory_area":"Laboratorium ścieków – Badania","regulatory_area_en":"Waste Water Laboratory – Tests","regulatory_area_zh":"废水实验室 – 检测","regulatory_area_cs":"Laboratoř odpadních vod – Zkoušky","flexible":true,"flexibility":"A","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Osad, osad denny, skratki, piasek, grunt Oznaczanie azotu ogólnego za pomocą analizatora TN (N og.) analizator azotu ogólnego (TN) Kal, sediment, shrabky, písek, zemina Stanovení dusíku celkového pomocí analyzátoru TN (N cel.) pomocí analyzátoru TN SOP-O-67/C, 25/N cel. Část B (ČSN EN ISO 20236) Osad, osad denny, skratki, piasek, grunt Oznaczanie azotu ogolnego za pomoca analizatora TN (N og.) analizator azotu ogolnego (TN) Kal, sediment, shrabky, pisek, zemina Stanoveni dusiku celkoveho pomoci analyzatoru TN (N cel.) pomoci analyzatoru TN SOP-O-67/C, 25/N cel. Cast B (CSN EN ISO 20236)","search_en":"Sludge, sediment, screenings, sand, soil Determination of total nitrogen using a TN analyser (N tot.) TN analyser SOP-O-67/C, 25/N cel. Část B (ČSN EN ISO 20236)","search_zh":"污泥、沉积物、栅渣、砂、土壤 总氮分析仪测定总氮 总氮分析仪 SOP-O-67/C, 25/N cel. Část B (ČSN EN ISO 20236)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":35,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"d260ccd557cd093f62929a11","lab_id":"69ad52a4de79e566650fd2e2","country":"CZ","accr_number":"1202","accr_body":"ČIA","row_label":"37","test_object":"Woda pitna, surowa (powierzchniowa, podziemna), użytkowa, ścieki, wyciąg wodny z osadu, osadu dennego, skratek, piasku, gruntu","test_object_en":"Drinking water, raw water (surface, ground), service water, waste water, aqueous extract of sludge, sediment, screenings, sand, soil","test_object_zh":"饮用水、原水（地表水、地下水）、杂用水、废水、污泥、沉积物、栅渣、砂和土壤的水浸出液","test_object_cs":"Voda pitná, surová (povrchová, podzemní), užitková, odpadní, vodný výluh kalu, sedimentu, shrabků, písku, zeminy","methodology":"Oznaczanie węgla całkowitego, nieorganicznego za pomocą analizatora TC (TC, TIC), węgla organicznego, rozpuszczonego węgla organicznego obliczeniowo z wartości zmierzonych (OWO, RWO)","methodology_en":"Determination of total and inorganic carbon using a TC analyser (TC, TIC), organic carbon and dissolved organic carbon by calculation from measured values (TOC, DOC)","methodology_zh":"总碳分析仪测定总碳和无机碳（TC、TIC），并由测量值计算有机碳和溶解性有机碳（TOC、DOC）","methodology_cs":"Stanovení celkového, anorganického uhlíku, pomocí analyzátoru TC, (TC, TIC), organického uhlíku, rozpuštěného organického uhlíku výpočtem z naměřených hodnot (TOC, DOC)","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"analizator węgla całkowitego (TC)","technique_en":"TC analyser","technique_zh":"总碳分析仪","technique_cs":"pomocí analyzátoru TC","techniques":["analizator węgla całkowitego (TC)"],"techniques_en":["TC analyser"],"techniques_zh":["总碳分析仪"],"techniques_cs":["pomocí analyzátoru TC"],"computed":["węgiel organiczny, rozpuszczony węgiel organiczny (OWO, RWO) (obliczeniowo)"],"computed_en":["organic carbon, dissolved organic carbon by calculation from measured values (TOC, DOC)"],"computed_zh":["有机碳、溶解性有机碳（TOC、DOC）（由测量值计算）"],"computed_cs":["organického uhlíku, rozpuštěného organického uhlíku výpočtem z naměřených hodnot (TOC, DOC)"],"activity":"Oznaczanie węgla całkowitego, nieorganicznego za pomocą analizatora TC (TC, TIC), węgla organicznego, rozpuszczonego węgla organicznego obliczeniowo z wartości zmierzonych (OWO, RWO)\nanalizator węgla całkowitego (TC)","reference":"SOP-O-67/C, 25/N cel. (ČSN EN 1484; ČSN EN ISO 20236)","norm_bases":["SOP-O-67/C, 25/N cel.","ČSN EN 1484","ČSN EN ISO 20236"],"lab_section":"Laboratorium ścieków","lab_section_en":"Waste Water Laboratory","lab_section_zh":"废水实验室","lab_section_cs":"Laboratoř odpadních vod","lab_address":"Jateční 2581/40, 301 00 Plzeň","regulatory_area":"Laboratorium ścieków – Badania","regulatory_area_en":"Waste Water Laboratory – Tests","regulatory_area_zh":"废水实验室 – 检测","regulatory_area_cs":"Laboratoř odpadních vod – Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Woda pitna, surowa (powierzchniowa, podziemna), użytkowa, ścieki, wyciąg wodny z osadu, osadu dennego, skratek, piasku, gruntu Oznaczanie węgla całkowitego, nieorganicznego za pomocą analizatora TC (TC, TIC), węgla organicznego, rozpuszczonego węgla organicznego obliczeniowo z wartości zmierzonych (OWO, RWO) analizator węgla całkowitego (TC) węgiel organiczny, rozpuszczony węgiel organiczny (OWO, RWO) (obliczeniowo) Voda pitná, surová (povrchová, podzemní), užitková, odpadní, vodný výluh kalu, sedimentu, shrabků, písku, zeminy Stanovení celkového, anorganického uhlíku, pomocí analyzátoru TC, (TC, TIC), organického uhlíku, rozpuštěného organického uhlíku výpočtem z naměřených hodnot (TOC, DOC) pomocí analyzátoru TC organického uhlíku, rozpuštěného organického uhlíku výpočtem z naměřených hodnot (TOC, DOC) SOP-O-67/C, 25/N cel. (ČSN EN 1484; ČSN EN ISO 20236) Woda pitna, surowa (powierzchniowa, podziemna), uzytkowa, scieki, wyciag wodny z osadu, osadu dennego, skratek, piasku, gruntu Oznaczanie wegla calkowitego, nieorganicznego za pomoca analizatora TC (TC, TIC), wegla organicznego, rozpuszczonego wegla organicznego obliczeniowo z wartosci zmierzonych (OWO, RWO) analizator wegla calkowitego (TC) wegiel organiczny, rozpuszczony wegiel organiczny (OWO, RWO) (obliczeniowo) Voda pitna, surova (povrchova, podzemni), uzitkova, odpadni, vodny vyluh kalu, sedimentu, shrabku, pisku, zeminy Stanoveni celkoveho, anorganickeho uhliku, pomoci analyzatoru TC, (TC, TIC), organickeho uhliku, rozpusteneho organickeho uhliku vypoctem z namerenych hodnot (TOC, DOC) pomoci analyzatoru TC organickeho uhliku, rozpusteneho organickeho uhliku vypoctem z namerenych hodnot (TOC, DOC) SOP-O-67/C, 25/N cel. (CSN EN 1484; CSN EN ISO 20236)","search_en":"Drinking water, raw water (surface, ground), service water, waste water, aqueous extract of sludge, sediment, screenings, sand, soil Determination of total and inorganic carbon using a TC analyser (TC, TIC), organic carbon and dissolved organic carbon by calculation from measured values (TOC, DOC) TC analyser organic carbon, dissolved organic carbon by calculation from measured values (TOC, DOC) SOP-O-67/C, 25/N cel. (ČSN EN 1484; ČSN EN ISO 20236)","search_zh":"饮用水、原水（地表水、地下水）、杂用水、废水、污泥、沉积物、栅渣、砂和土壤的水浸出液 总碳分析仪测定总碳和无机碳（TC、TIC），并由测量值计算有机碳和溶解性有机碳（TOC、DOC） 总碳分析仪 有机碳、溶解性有机碳（TOC、DOC）（由测量值计算） SOP-O-67/C, 25/N cel. (ČSN EN 1484; ČSN EN ISO 20236)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":36,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"37a8d36c756cab242bc8d28e","lab_id":"69ad52a4de79e566650fd2e2","country":"CZ","accr_number":"1202","accr_body":"ČIA","row_label":"38","test_object":"Woda pitna, surowa (powierzchniowa, podziemna), użytkowa","test_object_en":"Drinking water, raw water (surface, ground), service water","test_object_zh":"饮用水、原水（地表水、地下水）、杂用水","test_object_cs":"Voda pitná, surová (povrchová, podzemní), užitková","methodology":"Oznaczanie metali metodą ICP/MS i twardości obliczeniowo z wartości zmierzonych","methodology_en":"Determination of metals by ICP/MS method and hardness by calculation from measured values","methodology_zh":"ICP/MS法测定金属并由测量值计算硬度","methodology_cs":"Stanovení kovů metodou ICP/MS a tvrdosti výpočtem z naměřených hodnot","parameters":[{"name":"Srebro (Ag)","range":""},{"name":"Glin (Al)","range":""},{"name":"Arsen (As)","range":""},{"name":"Bor (B)","range":""},{"name":"Bar (Ba)","range":""},{"name":"Beryl (Be)","range":""},{"name":"Wapń (Ca)","range":""},{"name":"Kadm (Cd)","range":""},{"name":"Kobalt (Co)","range":""},{"name":"Chrom (Cr)","range":""},{"name":"Miedź (Cu)","range":""},{"name":"Żelazo (Fe)","range":""},{"name":"Potas (K)","range":""},{"name":"Magnez (Mg)","range":""},{"name":"Mangan (Mn)","range":""},{"name":"Molibden (Mo)","range":""},{"name":"Sód (Na)","range":""},{"name":"Nikiel (Ni)","range":""},{"name":"Fosfor (P)","range":""},{"name":"Ołów (Pb)","range":""},{"name":"Antymon (Sb)","range":""},{"name":"Selen (Se)","range":""},{"name":"Krzem (Si)","range":""},{"name":"Stront (Sr)","range":""},{"name":"Cyna (Sn)","range":""},{"name":"Wanad (V)","range":""},{"name":"Cynk (Zn)","range":""}],"parameters_en":[{"name":"Silver (Ag)","range":""},{"name":"Aluminium (Al)","range":""},{"name":"Arsenic (As)","range":""},{"name":"Boron (B)","range":""},{"name":"Barium (Ba)","range":""},{"name":"Beryllium (Be)","range":""},{"name":"Calcium (Ca)","range":""},{"name":"Cadmium (Cd)","range":""},{"name":"Cobalt (Co)","range":""},{"name":"Chromium (Cr)","range":""},{"name":"Copper (Cu)","range":""},{"name":"Iron (Fe)","range":""},{"name":"Potassium (K)","range":""},{"name":"Magnesium (Mg)","range":""},{"name":"Manganese (Mn)","range":""},{"name":"Molybdenum (Mo)","range":""},{"name":"Sodium (Na)","range":""},{"name":"Nickel (Ni)","range":""},{"name":"Phosphorus (P)","range":""},{"name":"Lead (Pb)","range":""},{"name":"Antimony (Sb)","range":""},{"name":"Selenium (Se)","range":""},{"name":"Silicon (Si)","range":""},{"name":"Strontium (Sr)","range":""},{"name":"Tin (Sn)","range":""},{"name":"Vanadium (V)","range":""},{"name":"Zinc (Zn)","range":""}],"parameters_zh":[{"name":"银（Ag）","range":""},{"name":"铝（Al）","range":""},{"name":"砷（As）","range":""},{"name":"硼（B）","range":""},{"name":"钡（Ba）","range":""},{"name":"铍（Be）","range":""},{"name":"钙（Ca）","range":""},{"name":"镉（Cd）","range":""},{"name":"钴（Co）","range":""},{"name":"铬（Cr）","range":""},{"name":"铜（Cu）","range":""},{"name":"铁（Fe）","range":""},{"name":"钾（K）","range":""},{"name":"镁（Mg）","range":""},{"name":"锰（Mn）","range":""},{"name":"钼（Mo）","range":""},{"name":"钠（Na）","range":""},{"name":"镍（Ni）","range":""},{"name":"磷（P）","range":""},{"name":"铅（Pb）","range":""},{"name":"锑（Sb）","range":""},{"name":"硒（Se）","range":""},{"name":"硅（Si）","range":""},{"name":"锶（Sr）","range":""},{"name":"锡（Sn）","range":""},{"name":"钒（V）","range":""},{"name":"锌（Zn）","range":""}],"parameters_cs":[{"name":"Ag","range":""},{"name":"Al","range":""},{"name":"As","range":""},{"name":"B","range":""},{"name":"Ba","range":""},{"name":"Be","range":""},{"name":"Ca","range":""},{"name":"Cd","range":""},{"name":"Co","range":""},{"name":"Cr","range":""},{"name":"Cu","range":""},{"name":"Fe","range":""},{"name":"K","range":""},{"name":"Mg","range":""},{"name":"Mn","range":""},{"name":"Mo","range":""},{"name":"Na","range":""},{"name":"Ni","range":""},{"name":"P","range":""},{"name":"Pb","range":""},{"name":"Sb","range":""},{"name":"Se","range":""},{"name":"Si","range":""},{"name":"Sr","range":""},{"name":"Sn","range":""},{"name":"V","range":""},{"name":"Zn","range":""}],"technique":"ICP-MS","technique_en":"ICP/MS method","technique_zh":"电感耦合等离子体质谱法（ICP/MS）","technique_cs":"metodou ICP/MS","techniques":["ICP-MS"],"techniques_en":["ICP/MS method"],"techniques_zh":["电感耦合等离子体质谱法（ICP/MS）"],"techniques_cs":["metodou ICP/MS"],"computed":["twardość (obliczeniowo z wartości zmierzonych)"],"computed_en":["hardness by calculation from measured values"],"computed_zh":["硬度（由测量值计算）"],"computed_cs":["tvrdosti výpočtem z naměřených hodnot"],"activity":"Oznaczanie metali metodą ICP/MS i twardości obliczeniowo z wartości zmierzonych\nZakres:\nSrebro (Ag)\nGlin (Al)\nArsen (As)\nBor (B)\nBar (Ba)\nBeryl (Be)\nWapń (Ca)\nKadm (Cd)\nKobalt (Co)\nChrom (Cr)\nMiedź (Cu)\nŻelazo (Fe)\nPotas (K)\nMagnez (Mg)\nMangan (Mn)\nMolibden (Mo)\nSód (Na)\nNikiel (Ni)\nFosfor (P)\nOłów (Pb)\nAntymon (Sb)\nSelen (Se)\nKrzem (Si)\nStront (Sr)\nCyna (Sn)\nWanad (V)\nCynk (Zn)\nICP-MS","reference":"SOP-O-84/kovy ICP MS-74/kovy část A (ČSN EN ISO 17294-1; ČSN EN ISO 17294-2)","norm_bases":["SOP-O-84/kovy ICP MS-74/kovy část A","ČSN EN ISO 17294-1","ČSN EN ISO 17294-2"],"lab_section":"Laboratorium ścieków","lab_section_en":"Waste Water Laboratory","lab_section_zh":"废水实验室","lab_section_cs":"Laboratoř odpadních vod","lab_address":"Jateční 2581/40, 301 00 Plzeň","regulatory_area":"Laboratorium ścieków – Badania","regulatory_area_en":"Waste Water Laboratory – Tests","regulatory_area_zh":"废水实验室 – 检测","regulatory_area_cs":"Laboratoř odpadních vod – Zkoušky","flexible":true,"flexibility":"B","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Woda pitna, surowa (powierzchniowa, podziemna), użytkowa Oznaczanie metali metodą ICP/MS i twardości obliczeniowo z wartości zmierzonych ICP-MS Srebro (Ag)  Glin (Al)  Arsen (As)  Bor (B)  Bar (Ba)  Beryl (Be)  Wapń (Ca)  Kadm (Cd)  Kobalt (Co)  Chrom (Cr)  Miedź (Cu)  Żelazo (Fe)  Potas (K)  Magnez (Mg)  Mangan (Mn)  Molibden (Mo)  Sód (Na)  Nikiel (Ni)  Fosfor (P)  Ołów (Pb)  Antymon (Sb)  Selen (Se)  Krzem (Si)  Stront (Sr)  Cyna (Sn)  Wanad (V)  Cynk (Zn)  twardość (obliczeniowo z wartości zmierzonych) Voda pitná, surová (povrchová, podzemní), užitková Stanovení kovů metodou ICP/MS a tvrdosti výpočtem z naměřených hodnot metodou ICP/MS Ag  Al  As  B  Ba  Be  Ca  Cd  Co  Cr  Cu  Fe  K  Mg  Mn  Mo  Na  Ni  P  Pb  Sb  Se  Si  Sr  Sn  V  Zn  tvrdosti výpočtem z naměřených hodnot SOP-O-84/kovy ICP MS-74/kovy část A (ČSN EN ISO 17294-1; ČSN EN ISO 17294-2) Woda pitna, surowa (powierzchniowa, podziemna), uzytkowa Oznaczanie metali metoda ICP/MS i twardosci obliczeniowo z wartosci zmierzonych ICP-MS Srebro (Ag)  Glin (Al)  Arsen (As)  Bor (B)  Bar (Ba)  Beryl (Be)  Wapn (Ca)  Kadm (Cd)  Kobalt (Co)  Chrom (Cr)  Miedz (Cu)  Zelazo (Fe)  Potas (K)  Magnez (Mg)  Mangan (Mn)  Molibden (Mo)  Sod (Na)  Nikiel (Ni)  Fosfor (P)  Olow (Pb)  Antymon (Sb)  Selen (Se)  Krzem (Si)  Stront (Sr)  Cyna (Sn)  Wanad (V)  Cynk (Zn)  twardosc (obliczeniowo z wartosci zmierzonych) Voda pitna, surova (povrchova, podzemni), uzitkova Stanoveni kovu metodou ICP/MS a tvrdosti vypoctem z namerenych hodnot metodou ICP/MS Ag  Al  As  B  Ba  Be  Ca  Cd  Co  Cr  Cu  Fe  K  Mg  Mn  Mo  Na  Ni  P  Pb  Sb  Se  Si  Sr  Sn  V  Zn  tvrdosti vypoctem z namerenych hodnot SOP-O-84/kovy ICP MS-74/kovy cast A (CSN EN ISO 17294-1; CSN EN ISO 17294-2)","search_en":"Drinking water, raw water (surface, ground), service water Determination of metals by ICP/MS method and hardness by calculation from measured values ICP/MS method Silver (Ag)  Aluminium (Al)  Arsenic (As)  Boron (B)  Barium (Ba)  Beryllium (Be)  Calcium (Ca)  Cadmium (Cd)  Cobalt (Co)  Chromium (Cr)  Copper (Cu)  Iron (Fe)  Potassium (K)  Magnesium (Mg)  Manganese (Mn)  Molybdenum (Mo)  Sodium (Na)  Nickel (Ni)  Phosphorus (P)  Lead (Pb)  Antimony (Sb)  Selenium (Se)  Silicon (Si)  Strontium (Sr)  Tin (Sn)  Vanadium (V)  Zinc (Zn)  hardness by calculation from measured values SOP-O-84/kovy ICP MS-74/kovy část A (ČSN EN ISO 17294-1; ČSN EN ISO 17294-2)","search_zh":"饮用水、原水（地表水、地下水）、杂用水 ICP/MS法测定金属并由测量值计算硬度 电感耦合等离子体质谱法（ICP/MS） 银（Ag）  铝（Al）  砷（As）  硼（B）  钡（Ba）  铍（Be）  钙（Ca）  镉（Cd）  钴（Co）  铬（Cr）  铜（Cu）  铁（Fe）  钾（K）  镁（Mg）  锰（Mn）  钼（Mo）  钠（Na）  镍（Ni）  磷（P）  铅（Pb）  锑（Sb）  硒（Se）  硅（Si）  锶（Sr）  锡（Sn）  钒（V）  锌（Zn）  硬度（由测量值计算） SOP-O-84/kovy ICP MS-74/kovy část A (ČSN EN ISO 17294-1; ČSN EN ISO 17294-2)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":37,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"134afa0d3534e4332c43780e","lab_id":"69ad52a4de79e566650fd2e2","country":"CZ","accr_number":"1202","accr_body":"ČIA","row_label":"39","test_object":"Ścieki, wyciąg wodny z osadu, osadu dennego, skratek, piasku, gruntu","test_object_en":"Waste water, aqueous extract of sludge, sediment, screenings, sand, soil","test_object_zh":"废水、污泥、沉积物、栅渣、砂和土壤的水浸出液","test_object_cs":"Voda odpadní, vodný výluh kalu, sedimentu, shrabků, písku, zeminy","methodology":"Oznaczanie metali metodą ICP/MS","methodology_en":"Determination of metals by ICP/MS method","methodology_zh":"ICP/MS法测定金属","methodology_cs":"Stanovení kovů metodou ICP/MS","parameters":[{"name":"Srebro (Ag)","range":""},{"name":"Glin (Al)","range":""},{"name":"Arsen (As)","range":""},{"name":"Bor (B)","range":""},{"name":"Bar (Ba)","range":""},{"name":"Beryl (Be)","range":""},{"name":"Wapń (Ca)","range":""},{"name":"Kadm (Cd)","range":""},{"name":"Kobalt (Co)","range":""},{"name":"Chrom (Cr)","range":""},{"name":"Miedź (Cu)","range":""},{"name":"Żelazo (Fe)","range":""},{"name":"Potas (K)","range":""},{"name":"Magnez (Mg)","range":""},{"name":"Mangan (Mn)","range":""},{"name":"Molibden (Mo)","range":""},{"name":"Sód (Na)","range":""},{"name":"Nikiel (Ni)","range":""},{"name":"Fosfor (P)","range":""},{"name":"Ołów (Pb)","range":""},{"name":"Antymon (Sb)","range":""},{"name":"Selen (Se)","range":""},{"name":"Cyna (Sn)","range":""},{"name":"Wanad (V)","range":""},{"name":"Cynk (Zn)","range":""}],"parameters_en":[{"name":"Silver (Ag)","range":""},{"name":"Aluminium (Al)","range":""},{"name":"Arsenic (As)","range":""},{"name":"Boron (B)","range":""},{"name":"Barium (Ba)","range":""},{"name":"Beryllium (Be)","range":""},{"name":"Calcium (Ca)","range":""},{"name":"Cadmium (Cd)","range":""},{"name":"Cobalt (Co)","range":""},{"name":"Chromium (Cr)","range":""},{"name":"Copper (Cu)","range":""},{"name":"Iron (Fe)","range":""},{"name":"Potassium (K)","range":""},{"name":"Magnesium (Mg)","range":""},{"name":"Manganese (Mn)","range":""},{"name":"Molybdenum (Mo)","range":""},{"name":"Sodium (Na)","range":""},{"name":"Nickel (Ni)","range":""},{"name":"Phosphorus (P)","range":""},{"name":"Lead (Pb)","range":""},{"name":"Antimony (Sb)","range":""},{"name":"Selenium (Se)","range":""},{"name":"Tin (Sn)","range":""},{"name":"Vanadium (V)","range":""},{"name":"Zinc (Zn)","range":""}],"parameters_zh":[{"name":"银（Ag）","range":""},{"name":"铝（Al）","range":""},{"name":"砷（As）","range":""},{"name":"硼（B）","range":""},{"name":"钡（Ba）","range":""},{"name":"铍（Be）","range":""},{"name":"钙（Ca）","range":""},{"name":"镉（Cd）","range":""},{"name":"钴（Co）","range":""},{"name":"铬（Cr）","range":""},{"name":"铜（Cu）","range":""},{"name":"铁（Fe）","range":""},{"name":"钾（K）","range":""},{"name":"镁（Mg）","range":""},{"name":"锰（Mn）","range":""},{"name":"钼（Mo）","range":""},{"name":"钠（Na）","range":""},{"name":"镍（Ni）","range":""},{"name":"磷（P）","range":""},{"name":"铅（Pb）","range":""},{"name":"锑（Sb）","range":""},{"name":"硒（Se）","range":""},{"name":"锡（Sn）","range":""},{"name":"钒（V）","range":""},{"name":"锌（Zn）","range":""}],"parameters_cs":[{"name":"Ag","range":""},{"name":"Al","range":""},{"name":"As","range":""},{"name":"B","range":""},{"name":"Ba","range":""},{"name":"Be","range":""},{"name":"Ca","range":""},{"name":"Cd","range":""},{"name":"Co","range":""},{"name":"Cr","range":""},{"name":"Cu","range":""},{"name":"Fe","range":""},{"name":"K","range":""},{"name":"Mg","range":""},{"name":"Mn","range":""},{"name":"Mo","range":""},{"name":"Na","range":""},{"name":"Ni","range":""},{"name":"P","range":""},{"name":"Pb","range":""},{"name":"Sb","range":""},{"name":"Se","range":""},{"name":"Sn","range":""},{"name":"V","range":""},{"name":"Zn","range":""}],"technique":"ICP-MS","technique_en":"ICP/MS method","technique_zh":"电感耦合等离子体质谱法（ICP/MS）","technique_cs":"metodou ICP/MS","techniques":["ICP-MS"],"techniques_en":["ICP/MS method"],"techniques_zh":["电感耦合等离子体质谱法（ICP/MS）"],"techniques_cs":["metodou ICP/MS"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie metali metodą ICP/MS\nZakres:\nSrebro (Ag)\nGlin (Al)\nArsen (As)\nBor (B)\nBar (Ba)\nBeryl (Be)\nWapń (Ca)\nKadm (Cd)\nKobalt (Co)\nChrom (Cr)\nMiedź (Cu)\nŻelazo (Fe)\nPotas (K)\nMagnez (Mg)\nMangan (Mn)\nMolibden (Mo)\nSód (Na)\nNikiel (Ni)\nFosfor (P)\nOłów (Pb)\nAntymon (Sb)\nSelen (Se)\nCyna (Sn)\nWanad (V)\nCynk (Zn)\nICP-MS","reference":"SOP-O-84/kovy ICP MS-74/kovy část B (ČSN EN ISO 17294-1; ČSN EN ISO 17294-2)","norm_bases":["SOP-O-84/kovy ICP MS-74/kovy část B","ČSN EN ISO 17294-1","ČSN EN ISO 17294-2"],"lab_section":"Laboratorium ścieków","lab_section_en":"Waste Water Laboratory","lab_section_zh":"废水实验室","lab_section_cs":"Laboratoř odpadních vod","lab_address":"Jateční 2581/40, 301 00 Plzeň","regulatory_area":"Laboratorium ścieków – Badania","regulatory_area_en":"Waste Water Laboratory – Tests","regulatory_area_zh":"废水实验室 – 检测","regulatory_area_cs":"Laboratoř odpadních vod – Zkoušky","flexible":true,"flexibility":"B","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Ścieki, wyciąg wodny z osadu, osadu dennego, skratek, piasku, gruntu Oznaczanie metali metodą ICP/MS ICP-MS Srebro (Ag)  Glin (Al)  Arsen (As)  Bor (B)  Bar (Ba)  Beryl (Be)  Wapń (Ca)  Kadm (Cd)  Kobalt (Co)  Chrom (Cr)  Miedź (Cu)  Żelazo (Fe)  Potas (K)  Magnez (Mg)  Mangan (Mn)  Molibden (Mo)  Sód (Na)  Nikiel (Ni)  Fosfor (P)  Ołów (Pb)  Antymon (Sb)  Selen (Se)  Cyna (Sn)  Wanad (V)  Cynk (Zn)  Voda odpadní, vodný výluh kalu, sedimentu, shrabků, písku, zeminy Stanovení kovů metodou ICP/MS metodou ICP/MS Ag  Al  As  B  Ba  Be  Ca  Cd  Co  Cr  Cu  Fe  K  Mg  Mn  Mo  Na  Ni  P  Pb  Sb  Se  Sn  V  Zn  SOP-O-84/kovy ICP MS-74/kovy část B (ČSN EN ISO 17294-1; ČSN EN ISO 17294-2) Scieki, wyciag wodny z osadu, osadu dennego, skratek, piasku, gruntu Oznaczanie metali metoda ICP/MS ICP-MS Srebro (Ag)  Glin (Al)  Arsen (As)  Bor (B)  Bar (Ba)  Beryl (Be)  Wapn (Ca)  Kadm (Cd)  Kobalt (Co)  Chrom (Cr)  Miedz (Cu)  Zelazo (Fe)  Potas (K)  Magnez (Mg)  Mangan (Mn)  Molibden (Mo)  Sod (Na)  Nikiel (Ni)  Fosfor (P)  Olow (Pb)  Antymon (Sb)  Selen (Se)  Cyna (Sn)  Wanad (V)  Cynk (Zn)  Voda odpadni, vodny vyluh kalu, sedimentu, shrabku, pisku, zeminy Stanoveni kovu metodou ICP/MS metodou ICP/MS Ag  Al  As  B  Ba  Be  Ca  Cd  Co  Cr  Cu  Fe  K  Mg  Mn  Mo  Na  Ni  P  Pb  Sb  Se  Sn  V  Zn  SOP-O-84/kovy ICP MS-74/kovy cast B (CSN EN ISO 17294-1; CSN EN ISO 17294-2)","search_en":"Waste water, aqueous extract of sludge, sediment, screenings, sand, soil Determination of metals by ICP/MS method ICP/MS method Silver (Ag)  Aluminium (Al)  Arsenic (As)  Boron (B)  Barium (Ba)  Beryllium (Be)  Calcium (Ca)  Cadmium (Cd)  Cobalt (Co)  Chromium (Cr)  Copper (Cu)  Iron (Fe)  Potassium (K)  Magnesium (Mg)  Manganese (Mn)  Molybdenum (Mo)  Sodium (Na)  Nickel (Ni)  Phosphorus (P)  Lead (Pb)  Antimony (Sb)  Selenium (Se)  Tin (Sn)  Vanadium (V)  Zinc (Zn)  SOP-O-84/kovy ICP MS-74/kovy část B (ČSN EN ISO 17294-1; ČSN EN ISO 17294-2)","search_zh":"废水、污泥、沉积物、栅渣、砂和土壤的水浸出液 ICP/MS法测定金属 电感耦合等离子体质谱法（ICP/MS） 银（Ag）  铝（Al）  砷（As）  硼（B）  钡（Ba）  铍（Be）  钙（Ca）  镉（Cd）  钴（Co）  铬（Cr）  铜（Cu）  铁（Fe）  钾（K）  镁（Mg）  锰（Mn）  钼（Mo）  钠（Na）  镍（Ni）  磷（P）  铅（Pb）  锑（Sb）  硒（Se）  锡（Sn）  钒（V）  锌（Zn）  SOP-O-84/kovy ICP MS-74/kovy část B (ČSN EN ISO 17294-1; ČSN EN ISO 17294-2)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":38,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"20a5352848f31c0a637c3dc4","lab_id":"69ad52a4de79e566650fd2e2","country":"CZ","accr_number":"1202","accr_body":"ČIA","row_label":"40","test_object":"Osad, osad denny, skratki, piasek, grunt","test_object_en":"Sludge, sediment, screenings, sand, soil","test_object_zh":"污泥、沉积物、栅渣、砂、土壤","test_object_cs":"Kal, sediment, shrabky, písek, zemina","methodology":"Oznaczanie metali metodą ICP/MS","methodology_en":"Determination of metals by ICP/MS method","methodology_zh":"ICP/MS法测定金属","methodology_cs":"Stanovení kovů metodou ICP/MS","parameters":[{"name":"Srebro (Ag)","range":""},{"name":"Glin (Al)","range":""},{"name":"Arsen (As)","range":""},{"name":"Bar (Ba)","range":""},{"name":"Beryl (Be)","range":""},{"name":"Wapń (Ca)","range":""},{"name":"Kadm (Cd)","range":""},{"name":"Kobalt (Co)","range":""},{"name":"Chrom (Cr)","range":""},{"name":"Miedź (Cu)","range":""},{"name":"Żelazo (Fe)","range":""},{"name":"Potas (K)","range":""},{"name":"Magnez (Mg)","range":""},{"name":"Molibden (Mo)","range":""},{"name":"Nikiel (Ni)","range":""},{"name":"Fosfor (P)","range":""},{"name":"Ołów (Pb)","range":""},{"name":"Selen (Se)","range":""},{"name":"Wanad (V)","range":""},{"name":"Cynk (Zn)","range":""}],"parameters_en":[{"name":"Silver (Ag)","range":""},{"name":"Aluminium (Al)","range":""},{"name":"Arsenic (As)","range":""},{"name":"Barium (Ba)","range":""},{"name":"Beryllium (Be)","range":""},{"name":"Calcium (Ca)","range":""},{"name":"Cadmium (Cd)","range":""},{"name":"Cobalt (Co)","range":""},{"name":"Chromium (Cr)","range":""},{"name":"Copper (Cu)","range":""},{"name":"Iron (Fe)","range":""},{"name":"Potassium (K)","range":""},{"name":"Magnesium (Mg)","range":""},{"name":"Molybdenum (Mo)","range":""},{"name":"Nickel (Ni)","range":""},{"name":"Phosphorus (P)","range":""},{"name":"Lead (Pb)","range":""},{"name":"Selenium (Se)","range":""},{"name":"Vanadium (V)","range":""},{"name":"Zinc (Zn)","range":""}],"parameters_zh":[{"name":"银（Ag）","range":""},{"name":"铝（Al）","range":""},{"name":"砷（As）","range":""},{"name":"钡（Ba）","range":""},{"name":"铍（Be）","range":""},{"name":"钙（Ca）","range":""},{"name":"镉（Cd）","range":""},{"name":"钴（Co）","range":""},{"name":"铬（Cr）","range":""},{"name":"铜（Cu）","range":""},{"name":"铁（Fe）","range":""},{"name":"钾（K）","range":""},{"name":"镁（Mg）","range":""},{"name":"钼（Mo）","range":""},{"name":"镍（Ni）","range":""},{"name":"磷（P）","range":""},{"name":"铅（Pb）","range":""},{"name":"硒（Se）","range":""},{"name":"钒（V）","range":""},{"name":"锌（Zn）","range":""}],"parameters_cs":[{"name":"Ag","range":""},{"name":"Al","range":""},{"name":"As","range":""},{"name":"Ba","range":""},{"name":"Be","range":""},{"name":"Ca","range":""},{"name":"Cd","range":""},{"name":"Co","range":""},{"name":"Cr","range":""},{"name":"Cu","range":""},{"name":"Fe","range":""},{"name":"K","range":""},{"name":"Mg","range":""},{"name":"Mo","range":""},{"name":"Ni","range":""},{"name":"P","range":""},{"name":"Pb","range":""},{"name":"Se","range":""},{"name":"V","range":""},{"name":"Zn","range":""}],"technique":"ICP-MS","technique_en":"ICP/MS method","technique_zh":"电感耦合等离子体质谱法（ICP/MS）","technique_cs":"metodou ICP/MS","techniques":["ICP-MS"],"techniques_en":["ICP/MS method"],"techniques_zh":["电感耦合等离子体质谱法（ICP/MS）"],"techniques_cs":["metodou ICP/MS"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie metali metodą ICP/MS\nZakres:\nSrebro (Ag)\nGlin (Al)\nArsen (As)\nBar (Ba)\nBeryl (Be)\nWapń (Ca)\nKadm (Cd)\nKobalt (Co)\nChrom (Cr)\nMiedź (Cu)\nŻelazo (Fe)\nPotas (K)\nMagnez (Mg)\nMolibden (Mo)\nNikiel (Ni)\nFosfor (P)\nOłów (Pb)\nSelen (Se)\nWanad (V)\nCynk (Zn)\nICP-MS","reference":"SOP-O-84/kovy ICP MS-74/kovy část C (ČSN EN ISO 17294-1; ČSN EN ISO 17294-2; ČSN EN 16173; ČSN EN 16171; ČSN EN ISO 54321)","norm_bases":["SOP-O-84/kovy ICP MS-74/kovy část C","ČSN EN ISO 17294-1","ČSN EN ISO 17294-2","ČSN EN 16173","ČSN EN 16171","ČSN EN ISO 54321"],"lab_section":"Laboratorium ścieków","lab_section_en":"Waste Water Laboratory","lab_section_zh":"废水实验室","lab_section_cs":"Laboratoř odpadních vod","lab_address":"Jateční 2581/40, 301 00 Plzeň","regulatory_area":"Laboratorium ścieków – Badania","regulatory_area_en":"Waste Water Laboratory – Tests","regulatory_area_zh":"废水实验室 – 检测","regulatory_area_cs":"Laboratoř odpadních vod – Zkoušky","flexible":true,"flexibility":"A, B","outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Osad, osad denny, skratki, piasek, grunt Oznaczanie metali metodą ICP/MS ICP-MS Srebro (Ag)  Glin (Al)  Arsen (As)  Bar (Ba)  Beryl (Be)  Wapń (Ca)  Kadm (Cd)  Kobalt (Co)  Chrom (Cr)  Miedź (Cu)  Żelazo (Fe)  Potas (K)  Magnez (Mg)  Molibden (Mo)  Nikiel (Ni)  Fosfor (P)  Ołów (Pb)  Selen (Se)  Wanad (V)  Cynk (Zn)  Kal, sediment, shrabky, písek, zemina Stanovení kovů metodou ICP/MS metodou ICP/MS Ag  Al  As  Ba  Be  Ca  Cd  Co  Cr  Cu  Fe  K  Mg  Mo  Ni  P  Pb  Se  V  Zn  SOP-O-84/kovy ICP MS-74/kovy část C (ČSN EN ISO 17294-1; ČSN EN ISO 17294-2; ČSN EN 16173; ČSN EN 16171; ČSN EN ISO 54321) Osad, osad denny, skratki, piasek, grunt Oznaczanie metali metoda ICP/MS ICP-MS Srebro (Ag)  Glin (Al)  Arsen (As)  Bar (Ba)  Beryl (Be)  Wapn (Ca)  Kadm (Cd)  Kobalt (Co)  Chrom (Cr)  Miedz (Cu)  Zelazo (Fe)  Potas (K)  Magnez (Mg)  Molibden (Mo)  Nikiel (Ni)  Fosfor (P)  Olow (Pb)  Selen (Se)  Wanad (V)  Cynk (Zn)  Kal, sediment, shrabky, pisek, zemina Stanoveni kovu metodou ICP/MS metodou ICP/MS Ag  Al  As  Ba  Be  Ca  Cd  Co  Cr  Cu  Fe  K  Mg  Mo  Ni  P  Pb  Se  V  Zn  SOP-O-84/kovy ICP MS-74/kovy cast C (CSN EN ISO 17294-1; CSN EN ISO 17294-2; CSN EN 16173; CSN EN 16171; CSN EN ISO 54321)","search_en":"Sludge, sediment, screenings, sand, soil Determination of metals by ICP/MS method ICP/MS method Silver (Ag)  Aluminium (Al)  Arsenic (As)  Barium (Ba)  Beryllium (Be)  Calcium (Ca)  Cadmium (Cd)  Cobalt (Co)  Chromium (Cr)  Copper (Cu)  Iron (Fe)  Potassium (K)  Magnesium (Mg)  Molybdenum (Mo)  Nickel (Ni)  Phosphorus (P)  Lead (Pb)  Selenium (Se)  Vanadium (V)  Zinc (Zn)  SOP-O-84/kovy ICP MS-74/kovy část C (ČSN EN ISO 17294-1; ČSN EN ISO 17294-2; ČSN EN 16173; ČSN EN 16171; ČSN EN ISO 54321)","search_zh":"污泥、沉积物、栅渣、砂、土壤 ICP/MS法测定金属 电感耦合等离子体质谱法（ICP/MS） 银（Ag）  铝（Al）  砷（As）  钡（Ba）  铍（Be）  钙（Ca）  镉（Cd）  钴（Co）  铬（Cr）  铜（Cu）  铁（Fe）  钾（K）  镁（Mg）  钼（Mo）  镍（Ni）  磷（P）  铅（Pb）  硒（Se）  钒（V）  锌（Zn）  SOP-O-84/kovy ICP MS-74/kovy část C (ČSN EN ISO 17294-1; ČSN EN ISO 17294-2; ČSN EN 16173; ČSN EN 16171; ČSN EN ISO 54321)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":39,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"615946d44032911a548575c5","lab_id":"69ad52a4de79e566650fd2e2","country":"CZ","accr_number":"1202","accr_body":"ČIA","row_label":"41","test_object":"Woda pitna, surowa (powierzchniowa, podziemna), użytkowa, ścieki","test_object_en":"Drinking water, raw water (surface, ground), service water, waste water","test_object_zh":"饮用水、原水（地表水、地下水）、杂用水、废水","test_object_cs":"Voda pitná, surová (povrchová, podzemní), užitková, odpadní","methodology":"Oznaczanie węglowodorów C10–C40 metodą GC z detekcją płomieniowo-jonizacyjną","methodology_en":"Determination of hydrocarbons C10 – C40 by GC with flame ionisation detection","methodology_zh":"气相色谱-火焰离子化检测法测定C10–C40烃类","methodology_cs":"Stanovení uhlovodíků C10 – C40 metodou GC s detekcí plamenově ionizační","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"GC-FID","technique_en":"GC with flame ionisation detection","technique_zh":"气相色谱-火焰离子化检测法","technique_cs":"metodou GC s detekcí plamenově ionizační","techniques":["GC-FID"],"techniques_en":["GC with flame ionisation detection"],"techniques_zh":["气相色谱-火焰离子化检测法"],"techniques_cs":["metodou GC s detekcí plamenově ionizační"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie węglowodorów C10–C40 metodą GC z detekcją płomieniowo-jonizacyjną\nGC-FID","reference":"SOP-O-30/ C10 – C40 (ČSN EN ISO 9377-2; TNI 757507)","norm_bases":["SOP-O-30/ C10 – C40","ČSN EN ISO 9377-2","TNI 757507"],"lab_section":"Laboratorium ścieków","lab_section_en":"Waste Water Laboratory","lab_section_zh":"废水实验室","lab_section_cs":"Laboratoř odpadních vod","lab_address":"Jateční 2581/40, 301 00 Plzeň","regulatory_area":"Laboratorium ścieków – Badania","regulatory_area_en":"Waste Water Laboratory – Tests","regulatory_area_zh":"废水实验室 – 检测","regulatory_area_cs":"Laboratoř odpadních vod – Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Woda pitna, surowa (powierzchniowa, podziemna), użytkowa, ścieki Oznaczanie węglowodorów C10–C40 metodą GC z detekcją płomieniowo-jonizacyjną GC-FID Voda pitná, surová (povrchová, podzemní), užitková, odpadní Stanovení uhlovodíků C10 – C40 metodou GC s detekcí plamenově ionizační metodou GC s detekcí plamenově ionizační SOP-O-30/ C10 – C40 (ČSN EN ISO 9377-2; TNI 757507) Woda pitna, surowa (powierzchniowa, podziemna), uzytkowa, scieki Oznaczanie weglowodorow C10–C40 metoda GC z detekcja plomieniowo-jonizacyjna GC-FID Voda pitna, surova (povrchova, podzemni), uzitkova, odpadni Stanoveni uhlovodiku C10 – C40 metodou GC s detekci plamenove ionizacni metodou GC s detekci plamenove ionizacni SOP-O-30/ C10 – C40 (CSN EN ISO 9377-2; TNI 757507)","search_en":"Drinking water, raw water (surface, ground), service water, waste water Determination of hydrocarbons C10 – C40 by GC with flame ionisation detection GC with flame ionisation detection SOP-O-30/ C10 – C40 (ČSN EN ISO 9377-2; TNI 757507)","search_zh":"饮用水、原水（地表水、地下水）、杂用水、废水 气相色谱-火焰离子化检测法测定C10–C40烃类 气相色谱-火焰离子化检测法 SOP-O-30/ C10 – C40 (ČSN EN ISO 9377-2; TNI 757507)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":40,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"9b0710052bc82d5a06e227dd","lab_id":"69ad52a4de79e566650fd2e2","country":"CZ","accr_number":"1202","accr_body":"ČIA","row_label":"42","test_object":"Woda pitna, surowa (powierzchniowa, podziemna), użytkowa, ścieki, wyciąg wodny z osadu, osadu dennego, skratek, piasku, gruntu","test_object_en":"Drinking water, raw water (surface, ground), service water, waste water, aqueous extract of sludge, sediment, screenings, sand, soil","test_object_zh":"饮用水、原水（地表水、地下水）、杂用水、废水、污泥、沉积物、栅渣、砂和土壤的水浸出液","test_object_cs":"Voda pitná, surová (povrchová, podzemní), užitková, odpadní, vodný výluh kalu, sedimentu, shrabků, písku, zeminy","methodology":"Oznaczanie analitów (PAL A, Cl-, SO42-, F-) metodą CFA","methodology_en":"Determination of analytes (PAL A, Cl-, SO42-, F-) by CFA method","methodology_zh":"连续流动分析法（CFA）测定分析物（PAL A、Cl-、SO42-、F-）","methodology_cs":"Stanovení analytů (PAL A, Cl-, SO42-, F-) metodou CFA","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"analiza przepływowa ciągła (CFA)","technique_en":"CFA method","technique_zh":"连续流动分析法（CFA）","technique_cs":"metodou CFA","techniques":["analiza przepływowa ciągła (CFA)"],"techniques_en":["CFA method"],"techniques_zh":["连续流动分析法（CFA）"],"techniques_cs":["metodou CFA"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie analitów (PAL A, Cl-, SO42-, F-) metodą CFA\nanaliza przepływowa ciągła (CFA)","reference":"SOP-O-86/analyty CFA II (ČSN ISO 16265; ČSN EN ISO 15682; ČSN ISO 22743; TNV 75 7431)","norm_bases":["SOP-O-86/analyty CFA II","ČSN ISO 16265","ČSN EN ISO 15682","ČSN ISO 22743","TNV 75 7431"],"lab_section":"Laboratorium ścieków","lab_section_en":"Waste Water Laboratory","lab_section_zh":"废水实验室","lab_section_cs":"Laboratoř odpadních vod","lab_address":"Jateční 2581/40, 301 00 Plzeň","regulatory_area":"Laboratorium ścieków – Badania","regulatory_area_en":"Waste Water Laboratory – Tests","regulatory_area_zh":"废水实验室 – 检测","regulatory_area_cs":"Laboratoř odpadních vod – Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Woda pitna, surowa (powierzchniowa, podziemna), użytkowa, ścieki, wyciąg wodny z osadu, osadu dennego, skratek, piasku, gruntu Oznaczanie analitów (PAL A, Cl-, SO42-, F-) metodą CFA analiza przepływowa ciągła (CFA) Voda pitná, surová (povrchová, podzemní), užitková, odpadní, vodný výluh kalu, sedimentu, shrabků, písku, zeminy Stanovení analytů (PAL A, Cl-, SO42-, F-) metodou CFA metodou CFA SOP-O-86/analyty CFA II (ČSN ISO 16265; ČSN EN ISO 15682; ČSN ISO 22743; TNV 75 7431) Woda pitna, surowa (powierzchniowa, podziemna), uzytkowa, scieki, wyciag wodny z osadu, osadu dennego, skratek, piasku, gruntu Oznaczanie analitow (PAL A, Cl-, SO42-, F-) metoda CFA analiza przeplywowa ciagla (CFA) Voda pitna, surova (povrchova, podzemni), uzitkova, odpadni, vodny vyluh kalu, sedimentu, shrabku, pisku, zeminy Stanoveni analytu (PAL A, Cl-, SO42-, F-) metodou CFA metodou CFA SOP-O-86/analyty CFA II (CSN ISO 16265; CSN EN ISO 15682; CSN ISO 22743; TNV 75 7431)","search_en":"Drinking water, raw water (surface, ground), service water, waste water, aqueous extract of sludge, sediment, screenings, sand, soil Determination of analytes (PAL A, Cl-, SO42-, F-) by CFA method CFA method SOP-O-86/analyty CFA II (ČSN ISO 16265; ČSN EN ISO 15682; ČSN ISO 22743; TNV 75 7431)","search_zh":"饮用水、原水（地表水、地下水）、杂用水、废水、污泥、沉积物、栅渣、砂和土壤的水浸出液 连续流动分析法（CFA）测定分析物（PAL A、Cl-、SO42-、F-） 连续流动分析法（CFA） SOP-O-86/analyty CFA II (ČSN ISO 16265; ČSN EN ISO 15682; ČSN ISO 22743; TNV 75 7431)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":41,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"97bd9d756c5eb75a888a5967","lab_id":"69ad52a4de79e566650fd2e2","country":"CZ","accr_number":"1202","accr_body":"ČIA","row_label":"1","test_object":"Woda pitna, surowa (powierzchniowa, podziemna do produkcji wody pitnej), użytkowa","test_object_en":"Drinking water, raw water (surface, ground for drinking water production), service water","test_object_zh":"饮用水、原水（用于生产饮用水的地表水、地下水）、杂用水","test_object_cs":"Voda pitná, surová (povrchová, podzemní pro výrobu pitné vody), užitková","methodology":"Pobieranie próbek wód","methodology_en":"Water sampling","methodology_zh":"水样采样","methodology_cs":"Odběr vzorků vod","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pobieranie próbek wód","reference":"SOP-500/odběr A (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN EN ISO 5667-16; ČSN ISO 5667-5; ČSN EN ISO 5667-14; ČSN EN ISO 19458; Vyhláška MZ č. 252/04 Sb.)","norm_bases":["SOP-500/odběr A","ČSN EN ISO 5667-1","ČSN EN ISO 5667-3","ČSN EN ISO 5667-16","ČSN ISO 5667-5","ČSN EN ISO 5667-14","ČSN EN ISO 19458","Vyhláška MZ č. 252/04 Sb."],"lab_section":"Laboratorium ścieków","lab_section_en":"Waste Water Laboratory","lab_section_zh":"废水实验室","lab_section_cs":"Laboratoř odpadních vod","lab_address":"Jateční 2581/40, 301 00 Plzeň","regulatory_area":"Laboratorium ścieków – Pobieranie próbek","regulatory_area_en":"Waste Water Laboratory – Sampling","regulatory_area_zh":"废水实验室 – 采样","regulatory_area_cs":"Laboratoř odpadních vod – Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Woda pitna, surowa (powierzchniowa, podziemna do produkcji wody pitnej), użytkowa Pobieranie próbek wód Voda pitná, surová (povrchová, podzemní pro výrobu pitné vody), užitková Odběr vzorků vod SOP-500/odběr A (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN EN ISO 5667-16; ČSN ISO 5667-5; ČSN EN ISO 5667-14; ČSN EN ISO 19458; Vyhláška MZ č. 252/04 Sb.) Woda pitna, surowa (powierzchniowa, podziemna do produkcji wody pitnej), uzytkowa Pobieranie probek wod Voda pitna, surova (povrchova, podzemni pro vyrobu pitne vody), uzitkova Odber vzorku vod SOP-500/odber A (CSN EN ISO 5667-1; CSN EN ISO 5667-3; CSN EN ISO 5667-16; CSN ISO 5667-5; CSN EN ISO 5667-14; CSN EN ISO 19458; Vyhlaska MZ c. 252/04 Sb.)","search_en":"Drinking water, raw water (surface, ground for drinking water production), service water Water sampling SOP-500/odběr A (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN EN ISO 5667-16; ČSN ISO 5667-5; ČSN EN ISO 5667-14; ČSN EN ISO 19458; Vyhláška MZ č. 252/04 Sb.)","search_zh":"饮用水、原水（用于生产饮用水的地表水、地下水）、杂用水 水样采样 SOP-500/odběr A (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN EN ISO 5667-16; ČSN ISO 5667-5; ČSN EN ISO 5667-14; ČSN EN ISO 19458; Vyhláška MZ č. 252/04 Sb.)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":42,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"411ca7821c49d3208dee0b8a","lab_id":"69ad52a4de79e566650fd2e2","country":"CZ","accr_number":"1202","accr_body":"ČIA","row_label":"2","test_object":"Ścieki","test_object_en":"Waste water","test_object_zh":"废水","test_object_cs":"Voda odpadní","methodology":"Pobieranie próbek ścieków (ręczne i próbnikiem automatycznym)","methodology_en":"Sampling of waste water (manual and automatic sampler)","methodology_zh":"废水采样（手动和自动采样器）","methodology_cs":"Odběr vzorků odpadních vod (manuálním a automatický vzorkovačem)","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pobieranie próbek ścieków (ręczne i próbnikiem automatycznym)","reference":"SOP-500/odběr B1 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-10; ČSN EN ISO 5667-14; ČSN 75 7315)","norm_bases":["SOP-500/odběr B1","ČSN EN ISO 5667-1","ČSN EN ISO 5667-3","ČSN ISO 5667-10","ČSN EN ISO 5667-14","ČSN 75 7315"],"lab_section":"Laboratorium ścieków","lab_section_en":"Waste Water Laboratory","lab_section_zh":"废水实验室","lab_section_cs":"Laboratoř odpadních vod","lab_address":"Jateční 2581/40, 301 00 Plzeň","regulatory_area":"Laboratorium ścieków – Pobieranie próbek","regulatory_area_en":"Waste Water Laboratory – Sampling","regulatory_area_zh":"废水实验室 – 采样","regulatory_area_cs":"Laboratoř odpadních vod – Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Ścieki Pobieranie próbek ścieków (ręczne i próbnikiem automatycznym) Voda odpadní Odběr vzorků odpadních vod (manuálním a automatický vzorkovačem) SOP-500/odběr B1 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-10; ČSN EN ISO 5667-14; ČSN 75 7315) Scieki Pobieranie probek sciekow (reczne i probnikiem automatycznym) Voda odpadni Odber vzorku odpadnich vod (manualnim a automaticky vzorkovacem) SOP-500/odber B1 (CSN EN ISO 5667-1; CSN EN ISO 5667-3; CSN ISO 5667-10; CSN EN ISO 5667-14; CSN 75 7315)","search_en":"Waste water Sampling of waste water (manual and automatic sampler) SOP-500/odběr B1 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-10; ČSN EN ISO 5667-14; ČSN 75 7315)","search_zh":"废水 废水采样（手动和自动采样器） SOP-500/odběr B1 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-10; ČSN EN ISO 5667-14; ČSN 75 7315)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":43,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"afec5db96fd6e2d833d917de","lab_id":"69ad52a4de79e566650fd2e2","country":"CZ","accr_number":"1202","accr_body":"ČIA","row_label":"3","test_object":"Osad, osad denny, skratki, piasek, grunt","test_object_en":"Sludge, sediment, screenings, sand, soil","test_object_zh":"污泥、沉积物、栅渣、砂、土壤","test_object_cs":"Kal, sediment, shrabky, písek, zemina","methodology":"Pobieranie próbek osadów","methodology_en":"Sampling of sludge","methodology_zh":"污泥采样","methodology_cs":"Odběr vzorků kalů","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pobieranie próbek osadów","reference":"SOP-500/odběr B2 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN EN ISO 5667-13; ČSN EN ISO 5667-14; ČSN EN ISO 5667-15)","norm_bases":["SOP-500/odběr B2","ČSN EN ISO 5667-1","ČSN EN ISO 5667-3","ČSN EN ISO 5667-13","ČSN EN ISO 5667-14","ČSN EN ISO 5667-15"],"lab_section":"Laboratorium ścieków","lab_section_en":"Waste Water Laboratory","lab_section_zh":"废水实验室","lab_section_cs":"Laboratoř odpadních vod","lab_address":"Jateční 2581/40, 301 00 Plzeň","regulatory_area":"Laboratorium ścieków – Pobieranie próbek","regulatory_area_en":"Waste Water Laboratory – Sampling","regulatory_area_zh":"废水实验室 – 采样","regulatory_area_cs":"Laboratoř odpadních vod – Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Osad, osad denny, skratki, piasek, grunt Pobieranie próbek osadów Kal, sediment, shrabky, písek, zemina Odběr vzorků kalů SOP-500/odběr B2 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN EN ISO 5667-13; ČSN EN ISO 5667-14; ČSN EN ISO 5667-15) Osad, osad denny, skratki, piasek, grunt Pobieranie probek osadow Kal, sediment, shrabky, pisek, zemina Odber vzorku kalu SOP-500/odber B2 (CSN EN ISO 5667-1; CSN EN ISO 5667-3; CSN EN ISO 5667-13; CSN EN ISO 5667-14; CSN EN ISO 5667-15)","search_en":"Sludge, sediment, screenings, sand, soil Sampling of sludge SOP-500/odběr B2 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN EN ISO 5667-13; ČSN EN ISO 5667-14; ČSN EN ISO 5667-15)","search_zh":"污泥、沉积物、栅渣、砂、土壤 污泥采样 SOP-500/odběr B2 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN EN ISO 5667-13; ČSN EN ISO 5667-14; ČSN EN ISO 5667-15)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":44,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"b82167b9a33ee1a6837053e6","lab_id":"69ad52a4de79e566650fd2e2","country":"CZ","accr_number":"1202","accr_body":"ČIA","row_label":"1","test_object":"Woda pitna, surowa (powierzchniowa, podziemna), użytkowa","test_object_en":"Drinking water, raw water (surface, ground), service water","test_object_zh":"饮用水、原水（地表水、地下水）、杂用水","test_object_cs":"Voda pitná, surová (povrchová, podzemní), užitková","methodology":"Oznaczanie barwy metodą fotometryczną","methodology_en":"Determination of colour by photometry","methodology_zh":"光度法测定色度","methodology_cs":"Stanovení barvy fotometricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"metoda fotometryczna","technique_en":"by photometry","technique_zh":"光度法","technique_cs":"fotometricky","techniques":["metoda fotometryczna"],"techniques_en":["by photometry"],"techniques_zh":["光度法"],"techniques_cs":["fotometricky"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie barwy metodą fotometryczną\nmetoda fotometryczna","reference":"SOP-P-01/B (ČSN EN ISO 7887)","norm_bases":["SOP-P-01/B","ČSN EN ISO 7887"],"lab_section":"Laboratorium wód pitnych","lab_section_en":"Drinking Water Laboratory","lab_section_zh":"饮用水实验室","lab_section_cs":"Laboratoř pitných vod","lab_address":"Malostranská 143/2, Doudlevce, 326 00 Plzeň","regulatory_area":"Laboratorium wód pitnych – Badania","regulatory_area_en":"Drinking Water Laboratory – Tests","regulatory_area_zh":"饮用水实验室 – 检测","regulatory_area_cs":"Laboratoř pitných vod – Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Woda pitna, surowa (powierzchniowa, podziemna), użytkowa Oznaczanie barwy metodą fotometryczną metoda fotometryczna Voda pitná, surová (povrchová, podzemní), užitková Stanovení barvy fotometricky fotometricky SOP-P-01/B (ČSN EN ISO 7887) Woda pitna, surowa (powierzchniowa, podziemna), uzytkowa Oznaczanie barwy metoda fotometryczna metoda fotometryczna Voda pitna, surova (povrchova, podzemni), uzitkova Stanoveni barvy fotometricky fotometricky SOP-P-01/B (CSN EN ISO 7887)","search_en":"Drinking water, raw water (surface, ground), service water Determination of colour by photometry by photometry SOP-P-01/B (ČSN EN ISO 7887)","search_zh":"饮用水、原水（地表水、地下水）、杂用水 光度法测定色度 光度法 SOP-P-01/B (ČSN EN ISO 7887)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":45,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"7af56a3656c2b751b8db16ba","lab_id":"69ad52a4de79e566650fd2e2","country":"CZ","accr_number":"1202","accr_body":"ČIA","row_label":"2","test_object":"Woda pitna, surowa (podziemna), użytkowa","test_object_en":"Drinking water, raw water (ground), service water","test_object_zh":"饮用水、原水（地下水）、杂用水","test_object_cs":"Voda pitná, surová (podzemní), užitková","methodology":"Oznaczanie zapachu metodą sensoryczną","methodology_en":"Determination of odour by sensory method","methodology_zh":"感官法测定嗅","methodology_cs":"Stanovení pachu senzoricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"metoda sensoryczna","technique_en":"sensory method","technique_zh":"感官法","technique_cs":"senzoricky","techniques":["metoda sensoryczna"],"techniques_en":["sensory method"],"techniques_zh":["感官法"],"techniques_cs":["senzoricky"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zapachu metodą sensoryczną\nmetoda sensoryczna","reference":"SOP-P-02/pach (ČSN 757340; ČSN EN 1622)","norm_bases":["SOP-P-02/pach","ČSN 757340","ČSN EN 1622"],"lab_section":"Laboratorium wód pitnych","lab_section_en":"Drinking Water Laboratory","lab_section_zh":"饮用水实验室","lab_section_cs":"Laboratoř pitných vod","lab_address":"Malostranská 143/2, Doudlevce, 326 00 Plzeň","regulatory_area":"Laboratorium wód pitnych – Badania","regulatory_area_en":"Drinking Water Laboratory – Tests","regulatory_area_zh":"饮用水实验室 – 检测","regulatory_area_cs":"Laboratoř pitných vod – Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Woda pitna, surowa (podziemna), użytkowa Oznaczanie zapachu metodą sensoryczną metoda sensoryczna Voda pitná, surová (podzemní), užitková Stanovení pachu senzoricky senzoricky SOP-P-02/pach (ČSN 757340; ČSN EN 1622) Woda pitna, surowa (podziemna), uzytkowa Oznaczanie zapachu metoda sensoryczna metoda sensoryczna Voda pitna, surova (podzemni), uzitkova Stanoveni pachu senzoricky senzoricky SOP-P-02/pach (CSN 757340; CSN EN 1622)","search_en":"Drinking water, raw water (ground), service water Determination of odour by sensory method sensory method SOP-P-02/pach (ČSN 757340; ČSN EN 1622)","search_zh":"饮用水、原水（地下水）、杂用水 感官法测定嗅 感官法 SOP-P-02/pach (ČSN 757340; ČSN EN 1622)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":46,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"62de8625c0aaf2da4a2392ee","lab_id":"69ad52a4de79e566650fd2e2","country":"CZ","accr_number":"1202","accr_body":"ČIA","row_label":"3","test_object":"Woda pitna","test_object_en":"Drinking water","test_object_zh":"饮用水","test_object_cs":"Voda pitná","methodology":"Oznaczanie smaku metodą sensoryczną","methodology_en":"Determination of taste by sensory method","methodology_zh":"感官法测定味","methodology_cs":"Stanovení chuti senzoricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"metoda sensoryczna","technique_en":"sensory method","technique_zh":"感官法","technique_cs":"senzoricky","techniques":["metoda sensoryczna"],"techniques_en":["sensory method"],"techniques_zh":["感官法"],"techniques_cs":["senzoricky"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie smaku metodą sensoryczną\nmetoda sensoryczna","reference":"SOP-P-79/chuť (ČSN 757340; ČSN EN 1622)","norm_bases":["SOP-P-79/chuť","ČSN 757340","ČSN EN 1622"],"lab_section":"Laboratorium wód pitnych","lab_section_en":"Drinking Water Laboratory","lab_section_zh":"饮用水实验室","lab_section_cs":"Laboratoř pitných vod","lab_address":"Malostranská 143/2, Doudlevce, 326 00 Plzeň","regulatory_area":"Laboratorium wód pitnych – Badania","regulatory_area_en":"Drinking Water Laboratory – Tests","regulatory_area_zh":"饮用水实验室 – 检测","regulatory_area_cs":"Laboratoř pitných vod – Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Woda pitna Oznaczanie smaku metodą sensoryczną metoda sensoryczna Voda pitná Stanovení chuti senzoricky senzoricky SOP-P-79/chuť (ČSN 757340; ČSN EN 1622) Woda pitna Oznaczanie smaku metoda sensoryczna metoda sensoryczna Voda pitna Stanoveni chuti senzoricky senzoricky SOP-P-79/chut (CSN 757340; CSN EN 1622)","search_en":"Drinking water Determination of taste by sensory method sensory method SOP-P-79/chuť (ČSN 757340; ČSN EN 1622)","search_zh":"饮用水 感官法测定味 感官法 SOP-P-79/chuť (ČSN 757340; ČSN EN 1622)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":47,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"1ed35a2ddaeb00c505dee2af","lab_id":"69ad52a4de79e566650fd2e2","country":"CZ","accr_number":"1202","accr_body":"ČIA","row_label":"4","test_object":"Woda pitna, surowa (powierzchniowa, podziemna), użytkowa","test_object_en":"Drinking water, raw water (surface, ground), service water","test_object_zh":"饮用水、原水（地表水、地下水）、杂用水","test_object_cs":"Voda pitná, surová (povrchová, podzemní), užitková","methodology":"Oznaczanie przewodności metodą konduktometryczną","methodology_en":"Determination of conductivity by conductometry","methodology_zh":"电导法测定电导率","methodology_cs":"Stanovení konduktivity konduktometricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"metoda konduktometryczna","technique_en":"conductometry","technique_zh":"电导法","technique_cs":"konduktometricky","techniques":["metoda konduktometryczna"],"techniques_en":["conductometry"],"techniques_zh":["电导法"],"techniques_cs":["konduktometricky"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie przewodności metodą konduktometryczną\nmetoda konduktometryczna","reference":"SOP-P-04/KON (ČSN EN 27888)","norm_bases":["SOP-P-04/KON","ČSN EN 27888"],"lab_section":"Laboratorium wód pitnych","lab_section_en":"Drinking Water Laboratory","lab_section_zh":"饮用水实验室","lab_section_cs":"Laboratoř pitných vod","lab_address":"Malostranská 143/2, Doudlevce, 326 00 Plzeň","regulatory_area":"Laboratorium wód pitnych – Badania","regulatory_area_en":"Drinking Water Laboratory – Tests","regulatory_area_zh":"饮用水实验室 – 检测","regulatory_area_cs":"Laboratoř pitných vod – Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Woda pitna, surowa (powierzchniowa, podziemna), użytkowa Oznaczanie przewodności metodą konduktometryczną metoda konduktometryczna Voda pitná, surová (povrchová, podzemní), užitková Stanovení konduktivity konduktometricky konduktometricky SOP-P-04/KON (ČSN EN 27888) Woda pitna, surowa (powierzchniowa, podziemna), uzytkowa Oznaczanie przewodnosci metoda konduktometryczna metoda konduktometryczna Voda pitna, surova (povrchova, podzemni), uzitkova Stanoveni konduktivity konduktometricky konduktometricky SOP-P-04/KON (CSN EN 27888)","search_en":"Drinking water, raw water (surface, ground), service water Determination of conductivity by conductometry conductometry SOP-P-04/KON (ČSN EN 27888)","search_zh":"饮用水、原水（地表水、地下水）、杂用水 电导法测定电导率 电导法 SOP-P-04/KON (ČSN EN 27888)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":48,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"aa7770d3dec6ac950e1adec2","lab_id":"69ad52a4de79e566650fd2e2","country":"CZ","accr_number":"1202","accr_body":"ČIA","row_label":"5","test_object":"Woda pitna, surowa (powierzchniowa, podziemna), użytkowa","test_object_en":"Drinking water, raw water (surface, ground), service water","test_object_zh":"饮用水、原水（地表水、地下水）、杂用水","test_object_cs":"Voda pitná, surová (povrchová, podzemní), užitková","methodology":"Oznaczanie mętności metodą nefelometryczną","methodology_en":"Determination of turbidity by nephelometry","methodology_zh":"浊度计法测定浊度","methodology_cs":"Stanovení zákalu nefelometricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"metoda nefelometryczna","technique_en":"nephelometry","technique_zh":"浊度计法","technique_cs":"nefelometricky","techniques":["metoda nefelometryczna"],"techniques_en":["nephelometry"],"techniques_zh":["浊度计法"],"techniques_cs":["nefelometricky"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie mętności metodą nefelometryczną\nmetoda nefelometryczna","reference":"SOP-P-06/Z (ČSN EN ISO 7027-1)","norm_bases":["SOP-P-06/Z","ČSN EN ISO 7027-1"],"lab_section":"Laboratorium wód pitnych","lab_section_en":"Drinking Water Laboratory","lab_section_zh":"饮用水实验室","lab_section_cs":"Laboratoř pitných vod","lab_address":"Malostranská 143/2, Doudlevce, 326 00 Plzeň","regulatory_area":"Laboratorium wód pitnych – Badania","regulatory_area_en":"Drinking Water Laboratory – Tests","regulatory_area_zh":"饮用水实验室 – 检测","regulatory_area_cs":"Laboratoř pitných vod – Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Woda pitna, surowa (powierzchniowa, podziemna), użytkowa Oznaczanie mętności metodą nefelometryczną metoda nefelometryczna Voda pitná, surová (povrchová, podzemní), užitková Stanovení zákalu nefelometricky nefelometricky SOP-P-06/Z (ČSN EN ISO 7027-1) Woda pitna, surowa (powierzchniowa, podziemna), uzytkowa Oznaczanie metnosci metoda nefelometryczna metoda nefelometryczna Voda pitna, surova (povrchova, podzemni), uzitkova Stanoveni zakalu nefelometricky nefelometricky SOP-P-06/Z (CSN EN ISO 7027-1)","search_en":"Drinking water, raw water (surface, ground), service water Determination of turbidity by nephelometry nephelometry SOP-P-06/Z (ČSN EN ISO 7027-1)","search_zh":"饮用水、原水（地表水、地下水）、杂用水 浊度计法测定浊度 浊度计法 SOP-P-06/Z (ČSN EN ISO 7027-1)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":49,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"3eea1d2a18d8ada20de3d832","lab_id":"69ad52a4de79e566650fd2e2","country":"CZ","accr_number":"1202","accr_body":"ČIA","row_label":"6","test_object":"Woda pitna, surowa (powierzchniowa, podziemna), użytkowa","test_object_en":"Drinking water, raw water (surface, ground), service water","test_object_zh":"饮用水、原水（地表水、地下水）、杂用水","test_object_cs":"Voda pitná, surová (povrchová, podzemní), užitková","methodology":"Oznaczanie pH metodą potencjometryczną","methodology_en":"Determination of pH by potentiometry","methodology_zh":"电位法测定pH","methodology_cs":"Stanovení pH potenciometricky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"metoda potencjometryczna","technique_en":"by potentiometry","technique_zh":"电位法","technique_cs":"potenciometricky","techniques":["metoda potencjometryczna"],"techniques_en":["by potentiometry"],"techniques_zh":["电位法"],"techniques_cs":["potenciometricky"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie pH metodą potencjometryczną\nmetoda potencjometryczna","reference":"SOP-P-07/pH (ČSN ISO 10523)","norm_bases":["SOP-P-07/pH","ČSN ISO 10523"],"lab_section":"Laboratorium wód pitnych","lab_section_en":"Drinking Water Laboratory","lab_section_zh":"饮用水实验室","lab_section_cs":"Laboratoř pitných vod","lab_address":"Malostranská 143/2, Doudlevce, 326 00 Plzeň","regulatory_area":"Laboratorium wód pitnych – Badania","regulatory_area_en":"Drinking Water Laboratory – Tests","regulatory_area_zh":"饮用水实验室 – 检测","regulatory_area_cs":"Laboratoř pitných vod – Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Woda pitna, surowa (powierzchniowa, podziemna), użytkowa Oznaczanie pH metodą potencjometryczną metoda potencjometryczna Voda pitná, surová (povrchová, podzemní), užitková Stanovení pH potenciometricky potenciometricky SOP-P-07/pH (ČSN ISO 10523) Woda pitna, surowa (powierzchniowa, podziemna), uzytkowa Oznaczanie pH metoda potencjometryczna metoda potencjometryczna Voda pitna, surova (povrchova, podzemni), uzitkova Stanoveni pH potenciometricky potenciometricky SOP-P-07/pH (CSN ISO 10523)","search_en":"Drinking water, raw water (surface, ground), service water Determination of pH by potentiometry by potentiometry SOP-P-07/pH (ČSN ISO 10523)","search_zh":"饮用水、原水（地表水、地下水）、杂用水 电位法测定pH 电位法 SOP-P-07/pH (ČSN ISO 10523)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":50,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"4eccd55093c8f0fae07e28e1","lab_id":"69ad52a4de79e566650fd2e2","country":"CZ","accr_number":"1202","accr_body":"ČIA","row_label":"7","test_object":"Woda pitna, surowa (powierzchniowa, podziemna), użytkowa","test_object_en":"Drinking water, raw water (surface, ground), service water","test_object_zh":"饮用水、原水（地表水、地下水）、杂用水","test_object_cs":"Voda pitná, surová (povrchová, podzemní), užitková","methodology":"Oznaczanie kwasowej pojemności neutralizacyjnej metodą miareczkową (KNK4,5)","methodology_en":"Determination of acid neutralizing capacity by titration (ANC4.5)","methodology_zh":"滴定法测定酸中和能力（ANC4.5）","methodology_cs":"Stanovení kyselinové neutralizační kapacity titračně (KNK4.5)","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"metoda miareczkowa","technique_en":"by titration","technique_zh":"滴定法","technique_cs":"titračně","techniques":["metoda miareczkowa"],"techniques_en":["by titration"],"techniques_zh":["滴定法"],"techniques_cs":["titračně"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie kwasowej pojemności neutralizacyjnej metodą miareczkową (KNK4,5)\nmetoda miareczkowa","reference":"SOP-P-KNK4.5 (ČSN ISO 9963-1)","norm_bases":["SOP-P-KNK4.5","ČSN ISO 9963-1"],"lab_section":"Laboratorium wód pitnych","lab_section_en":"Drinking Water Laboratory","lab_section_zh":"饮用水实验室","lab_section_cs":"Laboratoř pitných vod","lab_address":"Malostranská 143/2, Doudlevce, 326 00 Plzeň","regulatory_area":"Laboratorium wód pitnych – Badania","regulatory_area_en":"Drinking Water Laboratory – Tests","regulatory_area_zh":"饮用水实验室 – 检测","regulatory_area_cs":"Laboratoř pitných vod – Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Woda pitna, surowa (powierzchniowa, podziemna), użytkowa Oznaczanie kwasowej pojemności neutralizacyjnej metodą miareczkową (KNK4,5) metoda miareczkowa Voda pitná, surová (povrchová, podzemní), užitková Stanovení kyselinové neutralizační kapacity titračně (KNK4.5) titračně SOP-P-KNK4.5 (ČSN ISO 9963-1) Woda pitna, surowa (powierzchniowa, podziemna), uzytkowa Oznaczanie kwasowej pojemnosci neutralizacyjnej metoda miareczkowa (KNK4,5) metoda miareczkowa Voda pitna, surova (povrchova, podzemni), uzitkova Stanoveni kyselinove neutralizacni kapacity titracne (KNK4.5) titracne SOP-P-KNK4.5 (CSN ISO 9963-1)","search_en":"Drinking water, raw water (surface, ground), service water Determination of acid neutralizing capacity by titration (ANC4.5) by titration SOP-P-KNK4.5 (ČSN ISO 9963-1)","search_zh":"饮用水、原水（地表水、地下水）、杂用水 滴定法测定酸中和能力（ANC4.5） 滴定法 SOP-P-KNK4.5 (ČSN ISO 9963-1)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":51,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"da2757413fe64fd8a357cf1c","lab_id":"69ad52a4de79e566650fd2e2","country":"CZ","accr_number":"1202","accr_body":"ČIA","row_label":"8","test_object":"Woda pitna, surowa (powierzchniowa, podziemna), użytkowa","test_object_en":"Drinking water, raw water (surface, ground), service water","test_object_zh":"饮用水、原水（地表水、地下水）、杂用水","test_object_cs":"Voda pitná, surová (povrchová, podzemní), užitková","methodology":"Oznaczanie chemicznego zapotrzebowania tlenu metodą nadmanganianową miareczkowo (ChZTMn)","methodology_en":"Determination of chemical oxygen demand by permanganate by titration (CODMn)","methodology_zh":"高锰酸盐滴定法测定化学需氧量（CODMn）","methodology_cs":"Stanovení chemické spotřeby kyslíku manganistanem titračně (CHSKMn)","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"metoda miareczkowa","technique_en":"by titration","technique_zh":"滴定法","technique_cs":"titračně","techniques":["metoda miareczkowa"],"techniques_en":["by titration"],"techniques_zh":["滴定法"],"techniques_cs":["titračně"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie chemicznego zapotrzebowania tlenu metodą nadmanganianową miareczkowo (ChZTMn)\nmetoda miareczkowa","reference":"SOP-P-12/CHSKMn (ČSN EN ISO 8467)","norm_bases":["SOP-P-12/CHSKMn","ČSN EN ISO 8467"],"lab_section":"Laboratorium wód pitnych","lab_section_en":"Drinking Water Laboratory","lab_section_zh":"饮用水实验室","lab_section_cs":"Laboratoř pitných vod","lab_address":"Malostranská 143/2, Doudlevce, 326 00 Plzeň","regulatory_area":"Laboratorium wód pitnych – Badania","regulatory_area_en":"Drinking Water Laboratory – Tests","regulatory_area_zh":"饮用水实验室 – 检测","regulatory_area_cs":"Laboratoř pitných vod – Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Woda pitna, surowa (powierzchniowa, podziemna), użytkowa Oznaczanie chemicznego zapotrzebowania tlenu metodą nadmanganianową miareczkowo (ChZTMn) metoda miareczkowa Voda pitná, surová (povrchová, podzemní), užitková Stanovení chemické spotřeby kyslíku manganistanem titračně (CHSKMn) titračně SOP-P-12/CHSKMn (ČSN EN ISO 8467) Woda pitna, surowa (powierzchniowa, podziemna), uzytkowa Oznaczanie chemicznego zapotrzebowania tlenu metoda nadmanganianowa miareczkowo (ChZTMn) metoda miareczkowa Voda pitna, surova (povrchova, podzemni), uzitkova Stanoveni chemicke spotreby kysliku manganistanem titracne (CHSKMn) titracne SOP-P-12/CHSKMn (CSN EN ISO 8467)","search_en":"Drinking water, raw water (surface, ground), service water Determination of chemical oxygen demand by permanganate by titration (CODMn) by titration SOP-P-12/CHSKMn (ČSN EN ISO 8467)","search_zh":"饮用水、原水（地表水、地下水）、杂用水 高锰酸盐滴定法测定化学需氧量（CODMn） 滴定法 SOP-P-12/CHSKMn (ČSN EN ISO 8467)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":52,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"e39aac38c67cbff154bb1df0","lab_id":"69ad52a4de79e566650fd2e2","country":"CZ","accr_number":"1202","accr_body":"ČIA","row_label":"9","test_object":"Woda pitna, surowa (powierzchniowa, podziemna), użytkowa","test_object_en":"Drinking water, raw water (surface, ground), service water","test_object_zh":"饮用水、原水（地表水、地下水）、杂用水","test_object_cs":"Voda pitná, surová (povrchová, podzemní), užitková","methodology":"Oznaczanie zawiesin metodą wagową (NL)","methodology_en":"Determination of suspended solids by gravimetry (SS)","methodology_zh":"重量法测定悬浮物（SS）","methodology_cs":"Stanovení nerozpuštěných látek gravimetricky (NL)","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"metoda wagowa","technique_en":"by gravimetry","technique_zh":"重量法","technique_cs":"gravimetricky","techniques":["metoda wagowa"],"techniques_en":["by gravimetry"],"techniques_zh":["重量法"],"techniques_cs":["gravimetricky"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawiesin metodą wagową (NL)\nmetoda wagowa","reference":"SOP-P-16/NL (ČSN EN 872)","norm_bases":["SOP-P-16/NL","ČSN EN 872"],"lab_section":"Laboratorium wód pitnych","lab_section_en":"Drinking Water Laboratory","lab_section_zh":"饮用水实验室","lab_section_cs":"Laboratoř pitných vod","lab_address":"Malostranská 143/2, Doudlevce, 326 00 Plzeň","regulatory_area":"Laboratorium wód pitnych – Badania","regulatory_area_en":"Drinking Water Laboratory – Tests","regulatory_area_zh":"饮用水实验室 – 检测","regulatory_area_cs":"Laboratoř pitných vod – Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Woda pitna, surowa (powierzchniowa, podziemna), użytkowa Oznaczanie zawiesin metodą wagową (NL) metoda wagowa Voda pitná, surová (povrchová, podzemní), užitková Stanovení nerozpuštěných látek gravimetricky (NL) gravimetricky SOP-P-16/NL (ČSN EN 872) Woda pitna, surowa (powierzchniowa, podziemna), uzytkowa Oznaczanie zawiesin metoda wagowa (NL) metoda wagowa Voda pitna, surova (povrchova, podzemni), uzitkova Stanoveni nerozpustenych latek gravimetricky (NL) gravimetricky SOP-P-16/NL (CSN EN 872)","search_en":"Drinking water, raw water (surface, ground), service water Determination of suspended solids by gravimetry (SS) by gravimetry SOP-P-16/NL (ČSN EN 872)","search_zh":"饮用水、原水（地表水、地下水）、杂用水 重量法测定悬浮物（SS） 重量法 SOP-P-16/NL (ČSN EN 872)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":53,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"d51428cd8e146049f04a900c","lab_id":"69ad52a4de79e566650fd2e2","country":"CZ","accr_number":"1202","accr_body":"ČIA","row_label":"10","test_object":"Woda pitna, surowa (powierzchniowa, podziemna), użytkowa","test_object_en":"Drinking water, raw water (surface, ground), service water","test_object_zh":"饮用水、原水（地表水、地下水）、杂用水","test_object_cs":"Voda pitná, surová (povrchová, podzemní), užitková","methodology":"Oznaczanie substancji rozpuszczonych metodą wagową (RL)","methodology_en":"Determination of dissolved solids by gravimetry (DS)","methodology_zh":"重量法测定溶解性固体（DS）","methodology_cs":"Stanovení rozpuštěných látek gravimetricky (RL)","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"metoda wagowa","technique_en":"by gravimetry","technique_zh":"重量法","technique_cs":"gravimetricky","techniques":["metoda wagowa"],"techniques_en":["by gravimetry"],"techniques_zh":["重量法"],"techniques_cs":["gravimetricky"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie substancji rozpuszczonych metodą wagową (RL)\nmetoda wagowa","reference":"SOP-P-18/RL (ČSN 75 7346)","norm_bases":["SOP-P-18/RL","ČSN 75 7346"],"lab_section":"Laboratorium wód pitnych","lab_section_en":"Drinking Water Laboratory","lab_section_zh":"饮用水实验室","lab_section_cs":"Laboratoř pitných vod","lab_address":"Malostranská 143/2, Doudlevce, 326 00 Plzeň","regulatory_area":"Laboratorium wód pitnych – Badania","regulatory_area_en":"Drinking Water Laboratory – Tests","regulatory_area_zh":"饮用水实验室 – 检测","regulatory_area_cs":"Laboratoř pitných vod – Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Woda pitna, surowa (powierzchniowa, podziemna), użytkowa Oznaczanie substancji rozpuszczonych metodą wagową (RL) metoda wagowa Voda pitná, surová (povrchová, podzemní), užitková Stanovení rozpuštěných látek gravimetricky (RL) gravimetricky SOP-P-18/RL (ČSN 75 7346) Woda pitna, surowa (powierzchniowa, podziemna), uzytkowa Oznaczanie substancji rozpuszczonych metoda wagowa (RL) metoda wagowa Voda pitna, surova (povrchova, podzemni), uzitkova Stanoveni rozpustenych latek gravimetricky (RL) gravimetricky SOP-P-18/RL (CSN 75 7346)","search_en":"Drinking water, raw water (surface, ground), service water Determination of dissolved solids by gravimetry (DS) by gravimetry SOP-P-18/RL (ČSN 75 7346)","search_zh":"饮用水、原水（地表水、地下水）、杂用水 重量法测定溶解性固体（DS） 重量法 SOP-P-18/RL (ČSN 75 7346)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":54,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"e56fd707b8f80f326d506814","lab_id":"69ad52a4de79e566650fd2e2","country":"CZ","accr_number":"1202","accr_body":"ČIA","row_label":"11","test_object":"Woda pitna, surowa (powierzchniowa, podziemna), użytkowa","test_object_en":"Drinking water, raw water (surface, ground), service water","test_object_zh":"饮用水、原水（地表水、地下水）、杂用水","test_object_cs":"Voda pitná, surová (povrchová, podzemní), užitková","methodology":"Oznaczanie jonów amonowych metodą fotometryczną (NH4+), azotu amonowego (N-NH4+) obliczeniowo z wartości zmierzonych","methodology_en":"Determination of ammonium ions by photometry (NH4+), ammonia nitrogen (N-NH4+) by calculation from measured values","methodology_zh":"光度法测定铵离子（NH4+），并由测量值计算氨氮（N-NH4+）","methodology_cs":"Stanovení amonných iontů fotometricky (NH4+), dusíku amoniakálního (N-NH4+) výpočtem z naměřených hodnot","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"metoda fotometryczna","technique_en":"by photometry","technique_zh":"光度法","technique_cs":"fotometricky","techniques":["metoda fotometryczna"],"techniques_en":["by photometry"],"techniques_zh":["光度法"],"techniques_cs":["fotometricky"],"computed":["azot amonowy (N-NH4+) (obliczeniowo z wartości zmierzonych)"],"computed_en":["ammonia nitrogen (N-NH4+) by calculation from measured values"],"computed_zh":["氨氮（N-NH4+）（由测量值计算）"],"computed_cs":["dusíku amoniakálního (N-NH4+) výpočtem z naměřených hodnot"],"activity":"Oznaczanie jonów amonowych metodą fotometryczną (NH4+), azotu amonowego (N-NH4+) obliczeniowo z wartości zmierzonych\nmetoda fotometryczna","reference":"SOP-P-21/NH4+ (ČSN ISO 7150-1)","norm_bases":["SOP-P-21/NH4+","ČSN ISO 7150-1"],"lab_section":"Laboratorium wód pitnych","lab_section_en":"Drinking Water Laboratory","lab_section_zh":"饮用水实验室","lab_section_cs":"Laboratoř pitných vod","lab_address":"Malostranská 143/2, Doudlevce, 326 00 Plzeň","regulatory_area":"Laboratorium wód pitnych – Badania","regulatory_area_en":"Drinking Water Laboratory – Tests","regulatory_area_zh":"饮用水实验室 – 检测","regulatory_area_cs":"Laboratoř pitných vod – Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Woda pitna, surowa (powierzchniowa, podziemna), użytkowa Oznaczanie jonów amonowych metodą fotometryczną (NH4+), azotu amonowego (N-NH4+) obliczeniowo z wartości zmierzonych metoda fotometryczna azot amonowy (N-NH4+) (obliczeniowo z wartości zmierzonych) Voda pitná, surová (povrchová, podzemní), užitková Stanovení amonných iontů fotometricky (NH4+), dusíku amoniakálního (N-NH4+) výpočtem z naměřených hodnot fotometricky dusíku amoniakálního (N-NH4+) výpočtem z naměřených hodnot SOP-P-21/NH4+ (ČSN ISO 7150-1) Woda pitna, surowa (powierzchniowa, podziemna), uzytkowa Oznaczanie jonow amonowych metoda fotometryczna (NH4+), azotu amonowego (N-NH4+) obliczeniowo z wartosci zmierzonych metoda fotometryczna azot amonowy (N-NH4+) (obliczeniowo z wartosci zmierzonych) Voda pitna, surova (povrchova, podzemni), uzitkova Stanoveni amonnych iontu fotometricky (NH4+), dusiku amoniakalniho (N-NH4+) vypoctem z namerenych hodnot fotometricky dusiku amoniakalniho (N-NH4+) vypoctem z namerenych hodnot SOP-P-21/NH4+ (CSN ISO 7150-1)","search_en":"Drinking water, raw water (surface, ground), service water Determination of ammonium ions by photometry (NH4+), ammonia nitrogen (N-NH4+) by calculation from measured values by photometry ammonia nitrogen (N-NH4+) by calculation from measured values SOP-P-21/NH4+ (ČSN ISO 7150-1)","search_zh":"饮用水、原水（地表水、地下水）、杂用水 光度法测定铵离子（NH4+），并由测量值计算氨氮（N-NH4+） 光度法 氨氮（N-NH4+）（由测量值计算） SOP-P-21/NH4+ (ČSN ISO 7150-1)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":55,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"1fbbe9486042295719bafa66","lab_id":"69ad52a4de79e566650fd2e2","country":"CZ","accr_number":"1202","accr_body":"ČIA","row_label":"12","test_object":"Woda pitna, surowa (powierzchniowa, podziemna), użytkowa","test_object_en":"Drinking water, raw water (surface, ground), service water","test_object_zh":"饮用水、原水（地表水、地下水）、杂用水","test_object_cs":"Voda pitná, surová (povrchová, podzemní), užitková","methodology":"Oznaczanie azotynów metodą fotometryczną (NO2-), azotu azotynowego (N-NO2-) obliczeniowo z wartości zmierzonych","methodology_en":"Determination of nitrite by photometry (NO2-), nitrite nitrogen (N-NO2-) by calculation from measured values","methodology_zh":"光度法测定亚硝酸盐（NO2-），并由测量值计算亚硝酸盐氮（N-NO2-）","methodology_cs":"Stanovení dusitanů fotometricky (NO2-), dusíku dusitanového (N-NO2-) výpočtem z naměřených hodnot","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"metoda fotometryczna","technique_en":"by photometry","technique_zh":"光度法","technique_cs":"fotometricky","techniques":["metoda fotometryczna"],"techniques_en":["by photometry"],"techniques_zh":["光度法"],"techniques_cs":["fotometricky"],"computed":["azot azotynowy (N-NO2-) (obliczeniowo z wartości zmierzonych)"],"computed_en":["nitrite nitrogen (N-NO2-) by calculation from measured values"],"computed_zh":["亚硝酸盐氮（N-NO2-）（由测量值计算）"],"computed_cs":["dusíku dusitanového (N-NO2-) výpočtem z naměřených hodnot"],"activity":"Oznaczanie azotynów metodą fotometryczną (NO2-), azotu azotynowego (N-NO2-) obliczeniowo z wartości zmierzonych\nmetoda fotometryczna","reference":"SOP-P-22/NO2- (ČSN EN 26777)","norm_bases":["SOP-P-22/NO2-","ČSN EN 26777"],"lab_section":"Laboratorium wód pitnych","lab_section_en":"Drinking Water Laboratory","lab_section_zh":"饮用水实验室","lab_section_cs":"Laboratoř pitných vod","lab_address":"Malostranská 143/2, Doudlevce, 326 00 Plzeň","regulatory_area":"Laboratorium wód pitnych – Badania","regulatory_area_en":"Drinking Water Laboratory – Tests","regulatory_area_zh":"饮用水实验室 – 检测","regulatory_area_cs":"Laboratoř pitných vod – Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Woda pitna, surowa (powierzchniowa, podziemna), użytkowa Oznaczanie azotynów metodą fotometryczną (NO2-), azotu azotynowego (N-NO2-) obliczeniowo z wartości zmierzonych metoda fotometryczna azot azotynowy (N-NO2-) (obliczeniowo z wartości zmierzonych) Voda pitná, surová (povrchová, podzemní), užitková Stanovení dusitanů fotometricky (NO2-), dusíku dusitanového (N-NO2-) výpočtem z naměřených hodnot fotometricky dusíku dusitanového (N-NO2-) výpočtem z naměřených hodnot SOP-P-22/NO2- (ČSN EN 26777) Woda pitna, surowa (powierzchniowa, podziemna), uzytkowa Oznaczanie azotynow metoda fotometryczna (NO2-), azotu azotynowego (N-NO2-) obliczeniowo z wartosci zmierzonych metoda fotometryczna azot azotynowy (N-NO2-) (obliczeniowo z wartosci zmierzonych) Voda pitna, surova (povrchova, podzemni), uzitkova Stanoveni dusitanu fotometricky (NO2-), dusiku dusitanoveho (N-NO2-) vypoctem z namerenych hodnot fotometricky dusiku dusitanoveho (N-NO2-) vypoctem z namerenych hodnot SOP-P-22/NO2- (CSN EN 26777)","search_en":"Drinking water, raw water (surface, ground), service water Determination of nitrite by photometry (NO2-), nitrite nitrogen (N-NO2-) by calculation from measured values by photometry nitrite nitrogen (N-NO2-) by calculation from measured values SOP-P-22/NO2- (ČSN EN 26777)","search_zh":"饮用水、原水（地表水、地下水）、杂用水 光度法测定亚硝酸盐（NO2-），并由测量值计算亚硝酸盐氮（N-NO2-） 光度法 亚硝酸盐氮（N-NO2-）（由测量值计算） SOP-P-22/NO2- (ČSN EN 26777)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":56,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"4c927667771265e0f6636c95","lab_id":"69ad52a4de79e566650fd2e2","country":"CZ","accr_number":"1202","accr_body":"ČIA","row_label":"13","test_object":"Woda pitna, surowa (powierzchniowa, podziemna), użytkowa","test_object_en":"Drinking water, raw water (surface, ground), service water","test_object_zh":"饮用水、原水（地表水、地下水）、杂用水","test_object_cs":"Voda pitná, surová (povrchová, podzemní), užitková","methodology":"Oznaczanie lotnych związków organicznych metodą GC/MS (TOL)","methodology_en":"Determination of volatile organic compounds by GC/MS method (VOC)","methodology_zh":"气相色谱-质谱法测定挥发性有机物（TOL）","methodology_cs":"Stanovení těkavých organických látek metodou GC/MS (TOL)","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"GC/MS","technique_en":"GC/MS method","technique_zh":"气相色谱-质谱法","technique_cs":"metodou GC/MS","techniques":["GC/MS"],"techniques_en":["GC/MS method"],"techniques_zh":["气相色谱-质谱法"],"techniques_cs":["metodou GC/MS"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie lotnych związków organicznych metodą GC/MS (TOL)\nGC/MS","reference":"SOP-P-69/analyty GC MS - 65/TOL (ČSN EN ISO 10301; ČSN EN ISO 17943)","norm_bases":["SOP-P-69/analyty GC MS - 65/TOL","ČSN EN ISO 10301","ČSN EN ISO 17943"],"lab_section":"Laboratorium wód pitnych","lab_section_en":"Drinking Water Laboratory","lab_section_zh":"饮用水实验室","lab_section_cs":"Laboratoř pitných vod","lab_address":"Malostranská 143/2, Doudlevce, 326 00 Plzeň","regulatory_area":"Laboratorium wód pitnych – Badania","regulatory_area_en":"Drinking Water Laboratory – Tests","regulatory_area_zh":"饮用水实验室 – 检测","regulatory_area_cs":"Laboratoř pitných vod – Zkoušky","flexible":true,"flexibility":"B","outside_premises":false,"note":"Oznaczane anality: chloroform, 1,1,1-trichloroetan, 1,2-dichloroetan, benzen, tetrachlorometan, trichloroeten, bromodichlorometan, toluen, dibromochlorometan, tetrachloroeten, m+p-ksylen, chlorobenzen, 1,3-dichlorobenzen, 1,4-dichlorobenzen, 1,2-dichlorobenzen, o-ksylen, bromoform, cis-1,2-dichloroeten, etylobenzen, styren, dichlorometan, chloroeten (chlorek winylu), suma lotnych związków organicznych (TOL) – obliczeniowo z wartości zmierzonych","note_en":"Determined analytes: chloroform, 1,1,1-trichloroethane, 1,2-dichloroethane, benzene, tetrachloromethane, trichloroethene, bromodichloromethane, toluene, dibromochloromethane, tetrachloroethene, m+p-xylene, chlorobenzene, 1,3-dichlorobenzene, 1,4-dichlorobenzene, 1,2-dichlorobenzene, o-xylene, bromoform, cis-1,2-dichloroethene, ethylbenzene, styrene, dichloromethane, chloroethene (vinyl chloride), sum of volatile organic compounds (TOL) – by calculation from measured values","note_zh":"测定的分析物：氯仿、1,1,1-三氯乙烷、1,2-二氯乙烷、苯、四氯化碳、三氯乙烯、一溴二氯甲烷、甲苯、二溴一氯甲烷、四氯乙烯、间+对二甲苯、氯苯、1,3-二氯苯、1,4-二氯苯、1,2-二氯苯、邻二甲苯、溴仿、顺-1,2-二氯乙烯、乙苯、苯乙烯、二氯甲烷、氯乙烯，挥发性有机物总和（TOL）– 由测量值计算","note_cs":"Stanovované analyty: Chloroform, 1,1,1-trichlorethan, 1,2-dichlorethan, Benzen, Tetrachlormethan, 1,1,2-trichlorethen, Bromdichlormethan, Toluen, Dibromchlormethan, 1,1,2,2-tetrachlorethen, m+p-xylen, Chlorbenzen, 1,3-dichlorbenzen, 1,4-dichlorbenzen, 1,2-dichlorbenzen, o-xylen, Bromoform, cis 1,2-dichloroethen, Ethylbenzen, Styren, Dichlormethan, Chlorethen, suma TOL – výpočtem z naměřených hodnot","search_text":"Woda pitna, surowa (powierzchniowa, podziemna), użytkowa Oznaczanie lotnych związków organicznych metodą GC/MS (TOL) GC/MS Voda pitná, surová (povrchová, podzemní), užitková Stanovení těkavých organických látek metodou GC/MS (TOL) metodou GC/MS SOP-P-69/analyty GC MS - 65/TOL (ČSN EN ISO 10301; ČSN EN ISO 17943) Woda pitna, surowa (powierzchniowa, podziemna), uzytkowa Oznaczanie lotnych zwiazkow organicznych metoda GC/MS (TOL) GC/MS Voda pitna, surova (povrchova, podzemni), uzitkova Stanoveni tekavych organickych latek metodou GC/MS (TOL) metodou GC/MS SOP-P-69/analyty GC MS - 65/TOL (CSN EN ISO 10301; CSN EN ISO 17943)","search_en":"Drinking water, raw water (surface, ground), service water Determination of volatile organic compounds by GC/MS method (VOC) GC/MS method SOP-P-69/analyty GC MS - 65/TOL (ČSN EN ISO 10301; ČSN EN ISO 17943)","search_zh":"饮用水、原水（地表水、地下水）、杂用水 气相色谱-质谱法测定挥发性有机物（TOL） 气相色谱-质谱法 SOP-P-69/analyty GC MS - 65/TOL (ČSN EN ISO 10301; ČSN EN ISO 17943)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":57,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"fc4141f64d168edfca97e7e9","lab_id":"69ad52a4de79e566650fd2e2","country":"CZ","accr_number":"1202","accr_body":"ČIA","row_label":"14","test_object":"Woda pitna, surowa (powierzchniowa, podziemna), użytkowa","test_object_en":"Drinking water, raw water (surface, ground), service water","test_object_zh":"饮用水、原水（地表水、地下水）、杂用水","test_object_cs":"Voda pitná, surová (povrchová, podzemní), užitková","methodology":"Oznaczanie pestycydów, ich metabolitów i innych substancji organicznych metodą LC/MS/MS, sumy pestycydów obliczeniowo z wartości zmierzonych (PLC)","methodology_en":"Determination of pesticides, their metabolites and other organic substances by LC/MS/MS method, total pesticides by calculation from measured values (PLC)","methodology_zh":"液相色谱-串联质谱法测定农药、其代谢物及其他有机物，并由测量值计算农药总量（PLC）","methodology_cs":"Stanovení pesticidů, jejich metabolitů a dalších organických látek metodou LC/MS/MS, pesticidních látek celkem výpočtem z naměřených hodnot (PLC)","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"LC-MS/MS","technique_en":"LC/MS/MS method","technique_zh":"液相色谱-串联质谱法（LC/MS/MS）","technique_cs":"metodou LC/MS/MS","techniques":["LC-MS/MS"],"techniques_en":["LC/MS/MS method"],"techniques_zh":["液相色谱-串联质谱法（LC/MS/MS）"],"techniques_cs":["metodou LC/MS/MS"],"computed":["suma pestycydów (PLC) (obliczeniowo z wartości zmierzonych)"],"computed_en":["total pesticides by calculation from measured values (PLC)"],"computed_zh":["农药总量（PLC）（由测量值计算）"],"computed_cs":["pesticidních látek celkem výpočtem z naměřených hodnot (PLC)"],"activity":"Oznaczanie pestycydów, ich metabolitów i innych substancji organicznych metodą LC/MS/MS, sumy pestycydów obliczeniowo z wartości zmierzonych (PLC)\nLC-MS/MS","reference":"SOP-P-90/analyty LC MS, LC – PST ESI+ , 68/PLC (EPA Method 547; EPA Method 1694; EPA Method 535-1; EPA Method 536-1; EPA Method 537-1)","norm_bases":["SOP-P-90/analyty LC MS, LC – PST ESI+ , 68/PLC","EPA Method 547","EPA Method 1694","EPA Method 535-1","EPA Method 536-1","EPA Method 537-1"],"lab_section":"Laboratorium wód pitnych","lab_section_en":"Drinking Water Laboratory","lab_section_zh":"饮用水实验室","lab_section_cs":"Laboratoř pitných vod","lab_address":"Malostranská 143/2, Doudlevce, 326 00 Plzeň","regulatory_area":"Laboratorium wód pitnych – Badania","regulatory_area_en":"Drinking Water Laboratory – Tests","regulatory_area_zh":"饮用水实验室 – 检测","regulatory_area_cs":"Laboratoř pitných vod – Zkoušky","flexible":true,"flexibility":"B","outside_premises":false,"note":"Oznaczane anality: 1-H-Benzotriazol, 5-methyl-1-H Benzotriazol, Acetochlor, Acetochlor ESA, Acetochlor OA, Alachlor, Alachlor ESA, Alachlor OA, Ametryn, AMPA, Atrazine, atrazine-2-hydroxy, Atrazine-desethyl, Atrazine-desethyl-desisopropyl, Azoxystrobin, Clopyralid, Cyanazine, DEET, Desmetryn, Diazinon, Dichlorobenzamide 2,6-, Dimethachlor, Dimethachlor ESA, Dimethachlor OA, Diuron, Epoxikonazol, Glyphosate, Hexazinone, Chlorbromuron, Chlorfenvinphos, Chloridazone, Chloridazone-desphenyl, Chloridazone-methyl-desphenyl, Chlorotoluron, Isoproturon, Lenacil, Linuron, Metazachlor, Metazachlor ESA, Metazachlor OA, Methabenzthiazuron, Metobromuron, Metolachlor, Metolachlor ESA, Metolachlor OA, Metoxuron, Monolinuron, Prometryn, Propachlor, Propazine, Propiconazole, Sebuthylazin, Simazine, Tebuconazole, Terbuthylazine-2-hydroxy, Terbuthylazine-desethyl, Terbuthylazine-desethyl-2-hydroxy, Terbuthylazine, Terbutryn, Trietazine, suma pestycydów (PLC) – obliczeniowo z wartości zmierzonych","note_en":"Determined analytes: 1-H-Benzotriazol, 5-methyl-1-H Benzotriazol, Acetochlor, Acetochlor ESA, Acetochlor OA, Alachlor, Alachlor ESA, Alachlor OA, Ametryn, AMPA, Atrazine, atrazine-2-hydroxy, Atrazine-desethyl, Atrazine-desethyl-desisopropyl, Azoxystrobin, Clopyralid, Cyanazine, DEET, Desmetryn, Diazinon, Dichlorobenzamide 2,6-, Dimethachlor, Dimethachlor ESA, Dimethachlor OA, Diuron, Epoxikonazol, Glyphosate, Hexazinone, Chlorbromuron, Chlorfenvinphos, Chloridazone, Chloridazone-desphenyl, Chloridazone-methyl-desphenyl, Chlorotoluron, Isoproturon, Lenacil, Linuron, Metazachlor, Metazachlor ESA, Metazachlor OA, Methabenzthiazuron, Metobromuron, Metolachlor, Metolachlor ESA, Metolachlor OA, Metoxuron, Monolinuron, Prometryn, Propachlor, Propazine, Propiconazole, Sebuthylazin, Simazine, Tebuconazole, Terbuthylazine-2-hydroxy, Terbuthylazine-desethyl, Terbuthylazine-desethyl-2-hydroxy, Terbuthylazine, Terbutryn, Trietazine, sum of pesticides (PLC) – by calculation from measured values","note_zh":"测定的分析物：1-H-Benzotriazol, 5-methyl-1-H Benzotriazol, Acetochlor, Acetochlor ESA, Acetochlor OA, Alachlor, Alachlor ESA, Alachlor OA, Ametryn, AMPA, Atrazine, atrazine-2-hydroxy, Atrazine-desethyl, Atrazine-desethyl-desisopropyl, Azoxystrobin, Clopyralid, Cyanazine, DEET, Desmetryn, Diazinon, Dichlorobenzamide 2,6-, Dimethachlor, Dimethachlor ESA, Dimethachlor OA, Diuron, Epoxikonazol, Glyphosate, Hexazinone, Chlorbromuron, Chlorfenvinphos, Chloridazone, Chloridazone-desphenyl, Chloridazone-methyl-desphenyl, Chlorotoluron, Isoproturon, Lenacil, Linuron, Metazachlor, Metazachlor ESA, Metazachlor OA, Methabenzthiazuron, Metobromuron, Metolachlor, Metolachlor ESA, Metolachlor OA, Metoxuron, Monolinuron, Prometryn, Propachlor, Propazine, Propiconazole, Sebuthylazin, Simazine, Tebuconazole, Terbuthylazine-2-hydroxy, Terbuthylazine-desethyl, Terbuthylazine-desethyl-2-hydroxy, Terbuthylazine, Terbutryn, Trietazine，农药总和（PLC）– 由测量值计算","note_cs":"Stanovované analyty: 1-H-Benzotriazol, 5-methyl-1-H Benzotriazol, Acetochlor, Acetochlor ESA, Acetochlor OA, Alachlor, Alachlor ESA, Alachlor OA, Ametryn, AMPA, Atrazine, atrazine-2-hydroxy, Atrazine-desethyl, Atrazine-desethyl-desisopropyl, Azoxystrobin, Clopyralid, Cyanazine, DEET, Desmetryn, Diazinon, Dichlorobenzamide 2,6-, Dimethachlor, Dimethachlor ESA, Dimethachlor OA, Diuron, Epoxikonazol, Glyphosate, Hexazinone, Chlorbromuron, Chlorfenvinphos, Chloridazone, Chloridazone-desphenyl, Chloridazone-methyl-desphenyl, Chlorotoluron, Isoproturon, Lenacil, Linuron, Metazachlor, Metazachlor ESA, Metazachlor OA, Methabenzthiazuron, Metobromuron, Metolachlor, Metolachlor ESA, Metolachlor OA, Metoxuron, Monolinuron, Prometryn, Propachlor, Propazine, Propiconazole, Sebuthylazin, Simazine, Tebuconazole, Terbuthylazine-2-hydroxy, Terbuthylazine-desethyl, Terbuthylazine-desethyl-2-hydroxy, Terbuthylazine, Terbutryn, Trietazine, suma PLC – výpočtem z naměřených hodnot","search_text":"Woda pitna, surowa (powierzchniowa, podziemna), użytkowa Oznaczanie pestycydów, ich metabolitów i innych substancji organicznych metodą LC/MS/MS, sumy pestycydów obliczeniowo z wartości zmierzonych (PLC) LC-MS/MS suma pestycydów (PLC) (obliczeniowo z wartości zmierzonych) Voda pitná, surová (povrchová, podzemní), užitková Stanovení pesticidů, jejich metabolitů a dalších organických látek metodou LC/MS/MS, pesticidních látek celkem výpočtem z naměřených hodnot (PLC) metodou LC/MS/MS pesticidních látek celkem výpočtem z naměřených hodnot (PLC) SOP-P-90/analyty LC MS, LC – PST ESI+ , 68/PLC (EPA Method 547; EPA Method 1694; EPA Method 535-1; EPA Method 536-1; EPA Method 537-1) Woda pitna, surowa (powierzchniowa, podziemna), uzytkowa Oznaczanie pestycydow, ich metabolitow i innych substancji organicznych metoda LC/MS/MS, sumy pestycydow obliczeniowo z wartosci zmierzonych (PLC) LC-MS/MS suma pestycydow (PLC) (obliczeniowo z wartosci zmierzonych) Voda pitna, surova (povrchova, podzemni), uzitkova Stanoveni pesticidu, jejich metabolitu a dalsich organickych latek metodou LC/MS/MS, pesticidnich latek celkem vypoctem z namerenych hodnot (PLC) metodou LC/MS/MS pesticidnich latek celkem vypoctem z namerenych hodnot (PLC) SOP-P-90/analyty LC MS, LC – PST ESI+ , 68/PLC (EPA Method 547; EPA Method 1694; EPA Method 535-1; EPA Method 536-1; EPA Method 537-1)","search_en":"Drinking water, raw water (surface, ground), service water Determination of pesticides, their metabolites and other organic substances by LC/MS/MS method, total pesticides by calculation from measured values (PLC) LC/MS/MS method total pesticides by calculation from measured values (PLC) SOP-P-90/analyty LC MS, LC – PST ESI+ , 68/PLC (EPA Method 547; EPA Method 1694; EPA Method 535-1; EPA Method 536-1; EPA Method 537-1)","search_zh":"饮用水、原水（地表水、地下水）、杂用水 液相色谱-串联质谱法测定农药、其代谢物及其他有机物，并由测量值计算农药总量（PLC） 液相色谱-串联质谱法（LC/MS/MS） 农药总量（PLC）（由测量值计算） SOP-P-90/analyty LC MS, LC – PST ESI+ , 68/PLC (EPA Method 547; EPA Method 1694; EPA Method 535-1; EPA Method 536-1; EPA Method 537-1)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":58,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"751c389f3a8008547a13b584","lab_id":"69ad52a4de79e566650fd2e2","country":"CZ","accr_number":"1202","accr_body":"ČIA","row_label":"15","test_object":"Woda pitna, surowa (powierzchniowa, podziemna), użytkowa","test_object_en":"Drinking water, raw water (surface, ground), service water","test_object_zh":"饮用水、原水（地表水、地下水）、杂用水","test_object_cs":"Voda pitná, surová (povrchová, podzemní), užitková","methodology":"Oznaczanie pestycydów i innych substancji organicznych metodą LC/MS/MS","methodology_en":"Determination of pesticides and other organic substances by LC/MS/MS method","methodology_zh":"液相色谱-串联质谱法测定农药及其他有机物","methodology_cs":"Stanovení pesticidů a dalších organických látek metodou LC/MS/MS","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"LC-MS/MS","technique_en":"LC/MS/MS method","technique_zh":"液相色谱-串联质谱法（LC/MS/MS）","technique_cs":"metodou LC/MS/MS","techniques":["LC-MS/MS"],"techniques_en":["LC/MS/MS method"],"techniques_zh":["液相色谱-串联质谱法（LC/MS/MS）"],"techniques_cs":["metodou LC/MS/MS"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie pestycydów i innych substancji organicznych metodą LC/MS/MS\nLC-MS/MS","reference":"SOP-P-90/analyty LC MS, LC – PST ESI- , 68/PLC (EPA Method 547; EPA Method 1694; EPA Method 535-1; EPA Method 536-1; EPA Method 537-1)","norm_bases":["SOP-P-90/analyty LC MS, LC – PST ESI- , 68/PLC","EPA Method 547","EPA Method 1694","EPA Method 535-1","EPA Method 536-1","EPA Method 537-1"],"lab_section":"Laboratorium wód pitnych","lab_section_en":"Drinking Water Laboratory","lab_section_zh":"饮用水实验室","lab_section_cs":"Laboratoř pitných vod","lab_address":"Malostranská 143/2, Doudlevce, 326 00 Plzeň","regulatory_area":"Laboratorium wód pitnych – Badania","regulatory_area_en":"Drinking Water Laboratory – Tests","regulatory_area_zh":"饮用水实验室 – 检测","regulatory_area_cs":"Laboratoř pitných vod – Zkoušky","flexible":true,"flexibility":"B","outside_premises":false,"note":"Oznaczane anality: bentazon, dikamba, MCPA, PFOS","note_en":"Determined analytes: Bentazone, Dicamba, MCPA, PFOS","note_zh":"测定的分析物：灭草松、麦草畏、2甲4氯（MCPA）、全氟辛烷磺酸（PFOS）","note_cs":"Stanovované analyty: Bentazone, Dicamba, MCPA, PFOS","search_text":"Woda pitna, surowa (powierzchniowa, podziemna), użytkowa Oznaczanie pestycydów i innych substancji organicznych metodą LC/MS/MS LC-MS/MS Voda pitná, surová (povrchová, podzemní), užitková Stanovení pesticidů a dalších organických látek metodou LC/MS/MS metodou LC/MS/MS SOP-P-90/analyty LC MS, LC – PST ESI- , 68/PLC (EPA Method 547; EPA Method 1694; EPA Method 535-1; EPA Method 536-1; EPA Method 537-1) Woda pitna, surowa (powierzchniowa, podziemna), uzytkowa Oznaczanie pestycydow i innych substancji organicznych metoda LC/MS/MS LC-MS/MS Voda pitna, surova (povrchova, podzemni), uzitkova Stanoveni pesticidu a dalsich organickych latek metodou LC/MS/MS metodou LC/MS/MS SOP-P-90/analyty LC MS, LC – PST ESI- , 68/PLC (EPA Method 547; EPA Method 1694; EPA Method 535-1; EPA Method 536-1; EPA Method 537-1)","search_en":"Drinking water, raw water (surface, ground), service water Determination of pesticides and other organic substances by LC/MS/MS method LC/MS/MS method SOP-P-90/analyty LC MS, LC – PST ESI- , 68/PLC (EPA Method 547; EPA Method 1694; EPA Method 535-1; EPA Method 536-1; EPA Method 537-1)","search_zh":"饮用水、原水（地表水、地下水）、杂用水 液相色谱-串联质谱法测定农药及其他有机物 液相色谱-串联质谱法（LC/MS/MS） SOP-P-90/analyty LC MS, LC – PST ESI- , 68/PLC (EPA Method 547; EPA Method 1694; EPA Method 535-1; EPA Method 536-1; EPA Method 537-1)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":59,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"8ed71cebb59b7d05103a6a9c","lab_id":"69ad52a4de79e566650fd2e2","country":"CZ","accr_number":"1202","accr_body":"ČIA","row_label":"16","test_object":"Woda pitna, surowa (powierzchniowa, podziemna), użytkowa, ścieki, wyciąg wodny z osadu, osadu dennego, skratek, piasku, gruntu","test_object_en":"Drinking water, raw water (surface, ground), service water, waste water, aqueous extract of sludge, sediment, screenings, sand, soil","test_object_zh":"饮用水、原水（地表水、地下水）、杂用水、废水、污泥、沉积物、栅渣、砂和土壤的水浸出液","test_object_cs":"Voda pitná, surová (povrchová, podzemní), užitková, odpadní, vodný výluh kalu, sedimentu, shrabků, písku, zeminy","methodology":"Oznaczanie ogólnego węgla organicznego i rozpuszczonego węgla organicznego za pomocą analizatora TOC (OWO, RWO)","methodology_en":"Determination of total organic carbon and dissolved organic carbon using a TOC analyser (TOC, DOC)","methodology_zh":"总有机碳分析仪测定总有机碳和溶解性有机碳（TOC、DOC）","methodology_cs":"Stanovení celkového organického uhlíku a rozpuštěného organického uhlíku pomocí analyzátoru TOC (TOC, DOC)","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"analizator OWO (TOC)","technique_en":"TOC analyser","technique_zh":"总有机碳分析仪","technique_cs":"pomocí analyzátoru TOC","techniques":["analizator OWO (TOC)"],"techniques_en":["TOC analyser"],"techniques_zh":["总有机碳分析仪"],"techniques_cs":["pomocí analyzátoru TOC"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie ogólnego węgla organicznego i rozpuszczonego węgla organicznego za pomocą analizatora TOC (OWO, RWO)\nanalizator OWO (TOC)","reference":"SOP-P-67/C (ČSN EN 1484; ČSN EN ISO 20236)","norm_bases":["SOP-P-67/C","ČSN EN 1484","ČSN EN ISO 20236"],"lab_section":"Laboratorium wód pitnych","lab_section_en":"Drinking Water Laboratory","lab_section_zh":"饮用水实验室","lab_section_cs":"Laboratoř pitných vod","lab_address":"Malostranská 143/2, Doudlevce, 326 00 Plzeň","regulatory_area":"Laboratorium wód pitnych – Badania","regulatory_area_en":"Drinking Water Laboratory – Tests","regulatory_area_zh":"饮用水实验室 – 检测","regulatory_area_cs":"Laboratoř pitných vod – Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Woda pitna, surowa (powierzchniowa, podziemna), użytkowa, ścieki, wyciąg wodny z osadu, osadu dennego, skratek, piasku, gruntu Oznaczanie ogólnego węgla organicznego i rozpuszczonego węgla organicznego za pomocą analizatora TOC (OWO, RWO) analizator OWO (TOC) Voda pitná, surová (povrchová, podzemní), užitková, odpadní, vodný výluh kalu, sedimentu, shrabků, písku, zeminy Stanovení celkového organického uhlíku a rozpuštěného organického uhlíku pomocí analyzátoru TOC (TOC, DOC) pomocí analyzátoru TOC SOP-P-67/C (ČSN EN 1484; ČSN EN ISO 20236) Woda pitna, surowa (powierzchniowa, podziemna), uzytkowa, scieki, wyciag wodny z osadu, osadu dennego, skratek, piasku, gruntu Oznaczanie ogolnego wegla organicznego i rozpuszczonego wegla organicznego za pomoca analizatora TOC (OWO, RWO) analizator OWO (TOC) Voda pitna, surova (povrchova, podzemni), uzitkova, odpadni, vodny vyluh kalu, sedimentu, shrabku, pisku, zeminy Stanoveni celkoveho organickeho uhliku a rozpusteneho organickeho uhliku pomoci analyzatoru TOC (TOC, DOC) pomoci analyzatoru TOC SOP-P-67/C (CSN EN 1484; CSN EN ISO 20236)","search_en":"Drinking water, raw water (surface, ground), service water, waste water, aqueous extract of sludge, sediment, screenings, sand, soil Determination of total organic carbon and dissolved organic carbon using a TOC analyser (TOC, DOC) TOC analyser SOP-P-67/C (ČSN EN 1484; ČSN EN ISO 20236)","search_zh":"饮用水、原水（地表水、地下水）、杂用水、废水、污泥、沉积物、栅渣、砂和土壤的水浸出液 总有机碳分析仪测定总有机碳和溶解性有机碳（TOC、DOC） 总有机碳分析仪 SOP-P-67/C (ČSN EN 1484; ČSN EN ISO 20236)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":60,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"e80f218225902ff3231a1bee","lab_id":"69ad52a4de79e566650fd2e2","country":"CZ","accr_number":"1202","accr_body":"ČIA","row_label":"17","test_object":"Woda pitna, surowa (powierzchniowa, podziemna), użytkowa","test_object_en":"Drinking water, raw water (surface, ground), service water","test_object_zh":"饮用水、原水（地表水、地下水）、杂用水","test_object_cs":"Voda pitná, surová (povrchová, podzemní), užitková","methodology":"Oznaczanie pestycydów metodą GC/MS (PST)","methodology_en":"Determination of pesticides by GC/MS method (PST)","methodology_zh":"气相色谱-质谱法测定农药（PST）","methodology_cs":"Stanovení pesticidů metodou GC/MS (PST)","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"GC/MS","technique_en":"GC/MS method","technique_zh":"气相色谱-质谱法","technique_cs":"metodou GC/MS","techniques":["GC/MS"],"techniques_en":["GC/MS method"],"techniques_zh":["气相色谱-质谱法"],"techniques_cs":["metodou GC/MS"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie pestycydów metodą GC/MS (PST)\nGC/MS","reference":"SOP-P-69/analyty GC MS - 69/PST (OCP) (ČSN EN ISO 10695; ČSN EN ISO 6468; ČSN ISO 27108)","norm_bases":["SOP-P-69/analyty GC MS - 69/PST (OCP)","ČSN EN ISO 10695","ČSN EN ISO 6468","ČSN ISO 27108"],"lab_section":"Laboratorium wód pitnych","lab_section_en":"Drinking Water Laboratory","lab_section_zh":"饮用水实验室","lab_section_cs":"Laboratoř pitných vod","lab_address":"Malostranská 143/2, Doudlevce, 326 00 Plzeň","regulatory_area":"Laboratorium wód pitnych – Badania","regulatory_area_en":"Drinking Water Laboratory – Tests","regulatory_area_zh":"饮用水实验室 – 检测","regulatory_area_cs":"Laboratoř pitných vod – Zkoušky","flexible":true,"flexibility":"B","outside_premises":false,"note":"Oznaczane anality: dichlobenil, heksachlorobenzen, lindan, p,p'-DDE, p,p'-DDT, p,p'-metoksychlor, heptachlor, aldryna, dieldryna, epoksyd heptachloru, chloropiryfos, trifluralina, endryna, izodryna, pendimetalina","note_en":"Determined analytes: dichlobenil, hexachlorobenzene, lindane, p,p'-DDE, p,p'-DDT, p,p'-methoxychlor, heptachlor, aldrin, dieldrin, heptachlor epoxide, chlorpyrifos, trifluralin, endrin, isodrin, pendimethalin","note_zh":"测定的分析物：敌草腈、六氯苯、林丹、p,p'-DDE、p,p'-DDT、p,p'-甲氧滴滴涕、七氯、艾氏剂、狄氏剂、环氧七氯、毒死蜱、氟乐灵、异狄氏剂、异艾氏剂、二甲戊灵","note_cs":"Stanovované analyty: Dichlobenil, Hexachlorbenzen, Lindan, p,p´-DDE, p,p´-DDT, p,p´-Methoxychlor, Heptachlor, Aldrin, Dieldrin, Heptachlorepoxid, Chlorpyrifos, Trifluralin, Endrin, Isodrin, Pendimethalin","search_text":"Woda pitna, surowa (powierzchniowa, podziemna), użytkowa Oznaczanie pestycydów metodą GC/MS (PST) GC/MS Voda pitná, surová (povrchová, podzemní), užitková Stanovení pesticidů metodou GC/MS (PST) metodou GC/MS SOP-P-69/analyty GC MS - 69/PST (OCP) (ČSN EN ISO 10695; ČSN EN ISO 6468; ČSN ISO 27108) Woda pitna, surowa (powierzchniowa, podziemna), uzytkowa Oznaczanie pestycydow metoda GC/MS (PST) GC/MS Voda pitna, surova (povrchova, podzemni), uzitkova Stanoveni pesticidu metodou GC/MS (PST) metodou GC/MS SOP-P-69/analyty GC MS - 69/PST (OCP) (CSN EN ISO 10695; CSN EN ISO 6468; CSN ISO 27108)","search_en":"Drinking water, raw water (surface, ground), service water Determination of pesticides by GC/MS method (PST) GC/MS method SOP-P-69/analyty GC MS - 69/PST (OCP) (ČSN EN ISO 10695; ČSN EN ISO 6468; ČSN ISO 27108)","search_zh":"饮用水、原水（地表水、地下水）、杂用水 气相色谱-质谱法测定农药（PST） 气相色谱-质谱法 SOP-P-69/analyty GC MS - 69/PST (OCP) (ČSN EN ISO 10695; ČSN EN ISO 6468; ČSN ISO 27108)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":61,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"81bef60c68e97fa2eda6787f","lab_id":"69ad52a4de79e566650fd2e2","country":"CZ","accr_number":"1202","accr_body":"ČIA","row_label":"18","test_object":"Woda pitna, surowa (powierzchniowa, podziemna), użytkowa, ścieki, wyciąg wodny z osadu, osadu dennego, skratek, piasku, gruntu","test_object_en":"Drinking water, raw water (surface, ground), service water, waste water, aqueous extract of sludge, sediment, screenings, sand, soil","test_object_zh":"饮用水、原水（地表水、地下水）、杂用水、废水、污泥、沉积物、栅渣、砂和土壤的水浸出液","test_object_cs":"Voda pitná, surová (povrchová, podzemní), užitková, odpadní, vodný výluh kalu, sedimentu, shrabků, písku, zeminy","methodology":"Oznaczanie anionów metodą chromatografii jonowej i form azotu (N-NO2-, N-NO3-) obliczeniowo z wartości zmierzonych","methodology_en":"Determination of anions by IC method and nitrogen forms (N-NO2-, N-NO3-) by calculation from measured values","methodology_zh":"离子色谱法测定阴离子，并由测量值计算各形态氮（N-NO2-、N-NO3-）","methodology_cs":"Stanovení aniontů metodou IC a stanovení forem dusíku (N-NO2-, N-NO3-) výpočtem z naměřených hodnot","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"chromatografia jonowa","technique_en":"ion chromatography","technique_zh":"离子色谱法","technique_cs":"metodou IC","techniques":["chromatografia jonowa"],"techniques_en":["ion chromatography"],"techniques_zh":["离子色谱法"],"techniques_cs":["metodou IC"],"computed":["formy azotu (N-NO2-, N-NO3-) (obliczeniowo z wartości zmierzonych)"],"computed_en":["nitrogen forms (N-NO2-, N-NO3-) by calculation from measured values"],"computed_zh":["各形态氮（N-NO2-、N-NO3-）（由测量值计算）"],"computed_cs":["forem dusíku (N-NO2-, N-NO3-) výpočtem z naměřených hodnot"],"activity":"Oznaczanie anionów metodą chromatografii jonowej i form azotu (N-NO2-, N-NO3-) obliczeniowo z wartości zmierzonych\nchromatografia jonowa","reference":"SOP-P-85/anionty IC (ČSN EN ISO 10304-1; ČSN EN ISO 10304-4; ČSN EN ISO 15061; ČSN 75 7415; EPA Method 335.2)","norm_bases":["SOP-P-85/anionty IC","ČSN EN ISO 10304-1","ČSN EN ISO 10304-4","ČSN EN ISO 15061","ČSN 75 7415","EPA Method 335.2"],"lab_section":"Laboratorium wód pitnych","lab_section_en":"Drinking Water Laboratory","lab_section_zh":"饮用水实验室","lab_section_cs":"Laboratoř pitných vod","lab_address":"Malostranská 143/2, Doudlevce, 326 00 Plzeň","regulatory_area":"Laboratorium wód pitnych – Badania","regulatory_area_en":"Drinking Water Laboratory – Tests","regulatory_area_zh":"饮用水实验室 – 检测","regulatory_area_cs":"Laboratoř pitných vod – Zkoušky","flexible":true,"flexibility":"B","outside_premises":false,"note":"Oznaczane anality: (NO2-, NO3-, PO43-, Cl-, SO42-, F-, BrO3-, ClO3-, ClO2-) detekcja konduktometryczna (CD); (CN-) detekcja woltamperometryczna (VA); sumy anionów – obliczeniowo z wartości zmierzonych","note_en":"Determined analytes: (NO2-, NO3-, PO43-, Cl-, SO42-, F-, BrO3-, ClO3-, ClO2-) conductivity detection (CD); (CN-) voltammetric detection (VA); sums of anions – by calculation from measured values","note_zh":"测定的分析物：（NO2-、NO3-、PO43-、Cl-、SO42-、F-、BrO3-、ClO3-、ClO2-）电导检测（CD）；（CN-）伏安检测（VA）；阴离子总和 – 由测量值计算","note_cs":"Stanovované analyty: (NO2-, NO3-, PO43-, Cl-, SO42-, F-, BrO3-, ClO3-, ClO2-) detekce CD; (CN-) detekce VA; sumy aniontů – výpočtem z naměřených hodnot","search_text":"Woda pitna, surowa (powierzchniowa, podziemna), użytkowa, ścieki, wyciąg wodny z osadu, osadu dennego, skratek, piasku, gruntu Oznaczanie anionów metodą chromatografii jonowej i form azotu (N-NO2-, N-NO3-) obliczeniowo z wartości zmierzonych chromatografia jonowa formy azotu (N-NO2-, N-NO3-) (obliczeniowo z wartości zmierzonych) Voda pitná, surová (povrchová, podzemní), užitková, odpadní, vodný výluh kalu, sedimentu, shrabků, písku, zeminy Stanovení aniontů metodou IC a stanovení forem dusíku (N-NO2-, N-NO3-) výpočtem z naměřených hodnot metodou IC forem dusíku (N-NO2-, N-NO3-) výpočtem z naměřených hodnot SOP-P-85/anionty IC (ČSN EN ISO 10304-1; ČSN EN ISO 10304-4; ČSN EN ISO 15061; ČSN 75 7415; EPA Method 335.2) Woda pitna, surowa (powierzchniowa, podziemna), uzytkowa, scieki, wyciag wodny z osadu, osadu dennego, skratek, piasku, gruntu Oznaczanie anionow metoda chromatografii jonowej i form azotu (N-NO2-, N-NO3-) obliczeniowo z wartosci zmierzonych chromatografia jonowa formy azotu (N-NO2-, N-NO3-) (obliczeniowo z wartosci zmierzonych) Voda pitna, surova (povrchova, podzemni), uzitkova, odpadni, vodny vyluh kalu, sedimentu, shrabku, pisku, zeminy Stanoveni aniontu metodou IC a stanoveni forem dusiku (N-NO2-, N-NO3-) vypoctem z namerenych hodnot metodou IC forem dusiku (N-NO2-, N-NO3-) vypoctem z namerenych hodnot SOP-P-85/anionty IC (CSN EN ISO 10304-1; CSN EN ISO 10304-4; CSN EN ISO 15061; CSN 75 7415; EPA Method 335.2)","search_en":"Drinking water, raw water (surface, ground), service water, waste water, aqueous extract of sludge, sediment, screenings, sand, soil Determination of anions by IC method and nitrogen forms (N-NO2-, N-NO3-) by calculation from measured values ion chromatography nitrogen forms (N-NO2-, N-NO3-) by calculation from measured values SOP-P-85/anionty IC (ČSN EN ISO 10304-1; ČSN EN ISO 10304-4; ČSN EN ISO 15061; ČSN 75 7415; EPA Method 335.2)","search_zh":"饮用水、原水（地表水、地下水）、杂用水、废水、污泥、沉积物、栅渣、砂和土壤的水浸出液 离子色谱法测定阴离子，并由测量值计算各形态氮（N-NO2-、N-NO3-） 离子色谱法 各形态氮（N-NO2-、N-NO3-）（由测量值计算） SOP-P-85/anionty IC (ČSN EN ISO 10304-1; ČSN EN ISO 10304-4; ČSN EN ISO 15061; ČSN 75 7415; EPA Method 335.2)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":62,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"09630cf88f03ed2bf1fc60d2","lab_id":"69ad52a4de79e566650fd2e2","country":"CZ","accr_number":"1202","accr_body":"ČIA","row_label":"19","test_object":"Woda pitna, surowa (powierzchniowa, podziemna), użytkowa","test_object_en":"Drinking water, raw water (surface, ground), service water","test_object_zh":"饮用水、原水（地表水、地下水）、杂用水","test_object_cs":"Voda pitná, surová (povrchová, podzemní), užitková","methodology":"Oznaczanie drobnoustrojów hodowlanych w 22 °C metodą posiewu bezpośredniego na agarowe hodowlane podłoże odżywcze","methodology_en":"Enumeration of culturable microorganisms at 22 °C by direct plating on nutrient agar culture medium","methodology_zh":"营养琼脂培养基直接接种法计数22 °C可培养微生物","methodology_cs":"Stanovení kultivovatelných mikroorganismů 22 °C, metodou přímého výsevu do živného agarového kultivačního media","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"posiew bezpośredni na agarowe hodowlane podłoże odżywcze","technique_en":"direct plating on nutrient agar culture medium","technique_zh":"营养琼脂培养基直接接种法","technique_cs":"metodou přímého výsevu do živného agarového kultivačního media","techniques":["posiew bezpośredni na agarowe hodowlane podłoże odżywcze"],"techniques_en":["direct plating on nutrient agar culture medium"],"techniques_zh":["营养琼脂培养基直接接种法"],"techniques_cs":["metodou přímého výsevu do živného agarového kultivačního media"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie drobnoustrojów hodowlanych w 22 °C metodą posiewu bezpośredniego na agarowe hodowlane podłoże odżywcze\nposiew bezpośredni na agarowe hodowlane podłoże odżywcze","reference":"SOP-P-51/KM22 °C (ČSN EN ISO 6222)","norm_bases":["SOP-P-51/KM22 °C","ČSN EN ISO 6222"],"lab_section":"Laboratorium wód pitnych","lab_section_en":"Drinking Water Laboratory","lab_section_zh":"饮用水实验室","lab_section_cs":"Laboratoř pitných vod","lab_address":"Malostranská 143/2, Doudlevce, 326 00 Plzeň","regulatory_area":"Laboratorium wód pitnych – Badania","regulatory_area_en":"Drinking Water Laboratory – Tests","regulatory_area_zh":"饮用水实验室 – 检测","regulatory_area_cs":"Laboratoř pitných vod – Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Woda pitna, surowa (powierzchniowa, podziemna), użytkowa Oznaczanie drobnoustrojów hodowlanych w 22 °C metodą posiewu bezpośredniego na agarowe hodowlane podłoże odżywcze posiew bezpośredni na agarowe hodowlane podłoże odżywcze Voda pitná, surová (povrchová, podzemní), užitková Stanovení kultivovatelných mikroorganismů 22 °C, metodou přímého výsevu do živného agarového kultivačního media metodou přímého výsevu do živného agarového kultivačního media SOP-P-51/KM22 °C (ČSN EN ISO 6222) Woda pitna, surowa (powierzchniowa, podziemna), uzytkowa Oznaczanie drobnoustrojow hodowlanych w 22 °C metoda posiewu bezposredniego na agarowe hodowlane podloze odzywcze posiew bezposredni na agarowe hodowlane podloze odzywcze Voda pitna, surova (povrchova, podzemni), uzitkova Stanoveni kultivovatelnych mikroorganismu 22 °C, metodou primeho vysevu do zivneho agaroveho kultivacniho media metodou primeho vysevu do zivneho agaroveho kultivacniho media SOP-P-51/KM22 °C (CSN EN ISO 6222)","search_en":"Drinking water, raw water (surface, ground), service water Enumeration of culturable microorganisms at 22 °C by direct plating on nutrient agar culture medium direct plating on nutrient agar culture medium SOP-P-51/KM22 °C (ČSN EN ISO 6222)","search_zh":"饮用水、原水（地表水、地下水）、杂用水 营养琼脂培养基直接接种法计数22 °C可培养微生物 营养琼脂培养基直接接种法 SOP-P-51/KM22 °C (ČSN EN ISO 6222)","categories":["water","microbiology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":63,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"f95c08c938a9c9dab891e8c8","lab_id":"69ad52a4de79e566650fd2e2","country":"CZ","accr_number":"1202","accr_body":"ČIA","row_label":"20","test_object":"Woda pitna, surowa (powierzchniowa, podziemna), użytkowa","test_object_en":"Drinking water, raw water (surface, ground), service water","test_object_zh":"饮用水、原水（地表水、地下水）、杂用水","test_object_cs":"Voda pitná, surová (povrchová, podzemní), užitková","methodology":"Oznaczanie bakterii z grupy coli, Escherichia coli metodą filtracji membranowej","methodology_en":"Enumeration of coliform bacteria, Escherichia coli by membrane filtration","methodology_zh":"膜过滤法测定大肠菌群、大肠埃希氏菌","methodology_cs":"Stanovení koliformních bakterií, Escherichia coli membránovou filtrací","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"filtracja membranowa","technique_en":"membrane filtration","technique_zh":"膜过滤法","technique_cs":"membránovou filtrací","techniques":["filtracja membranowa"],"techniques_en":["membrane filtration"],"techniques_zh":["膜过滤法"],"techniques_cs":["membránovou filtrací"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie bakterii z grupy coli, Escherichia coli metodą filtracji membranowej\nfiltracja membranowa","reference":"SOP-P-52/KB, EC (ČSN EN ISO 9308-1:2001)","norm_bases":["SOP-P-52/KB, EC","ČSN EN ISO 9308-1:2001"],"lab_section":"Laboratorium wód pitnych","lab_section_en":"Drinking Water Laboratory","lab_section_zh":"饮用水实验室","lab_section_cs":"Laboratoř pitných vod","lab_address":"Malostranská 143/2, Doudlevce, 326 00 Plzeň","regulatory_area":"Laboratorium wód pitnych – Badania","regulatory_area_en":"Drinking Water Laboratory – Tests","regulatory_area_zh":"饮用水实验室 – 检测","regulatory_area_cs":"Laboratoř pitných vod – Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Woda pitna, surowa (powierzchniowa, podziemna), użytkowa Oznaczanie bakterii z grupy coli, Escherichia coli metodą filtracji membranowej filtracja membranowa Voda pitná, surová (povrchová, podzemní), užitková Stanovení koliformních bakterií, Escherichia coli membránovou filtrací membránovou filtrací SOP-P-52/KB, EC (ČSN EN ISO 9308-1:2001) Woda pitna, surowa (powierzchniowa, podziemna), uzytkowa Oznaczanie bakterii z grupy coli, Escherichia coli metoda filtracji membranowej filtracja membranowa Voda pitna, surova (povrchova, podzemni), uzitkova Stanoveni koliformnich bakterii, Escherichia coli membranovou filtraci membranovou filtraci SOP-P-52/KB, EC (CSN EN ISO 9308-1:2001)","search_en":"Drinking water, raw water (surface, ground), service water Enumeration of coliform bacteria, Escherichia coli by membrane filtration membrane filtration SOP-P-52/KB, EC (ČSN EN ISO 9308-1:2001)","search_zh":"饮用水、原水（地表水、地下水）、杂用水 膜过滤法测定大肠菌群、大肠埃希氏菌 膜过滤法 SOP-P-52/KB, EC (ČSN EN ISO 9308-1:2001)","categories":["water","microbiology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":64,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"765b8c98b4b0370020b354e9","lab_id":"69ad52a4de79e566650fd2e2","country":"CZ","accr_number":"1202","accr_body":"ČIA","row_label":"21","test_object":"Woda pitna","test_object_en":"Drinking water","test_object_zh":"饮用水","test_object_cs":"Voda pitná","methodology":"Oznaczanie bakterii z grupy coli, Escherichia coli metodą Colilert","methodology_en":"Enumeration of coliform bacteria, Escherichia coli by Colilert method","methodology_zh":"Colilert法测定大肠菌群、大肠埃希氏菌","methodology_cs":"Stanovení koliformních bakterií, Escherichia coli metodou Colilert","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"metoda Colilert","technique_en":"Colilert method","technique_zh":"Colilert法","technique_cs":"metodou Colilert","techniques":["metoda Colilert"],"techniques_en":["Colilert method"],"techniques_zh":["Colilert法"],"techniques_cs":["metodou Colilert"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie bakterii z grupy coli, Escherichia coli metodą Colilert\nmetoda Colilert","reference":"SOP-P-52a/KB, EC (ČSN EN ISO 9308-2)","norm_bases":["SOP-P-52a/KB, EC","ČSN EN ISO 9308-2"],"lab_section":"Laboratorium wód pitnych","lab_section_en":"Drinking Water Laboratory","lab_section_zh":"饮用水实验室","lab_section_cs":"Laboratoř pitných vod","lab_address":"Malostranská 143/2, Doudlevce, 326 00 Plzeň","regulatory_area":"Laboratorium wód pitnych – Badania","regulatory_area_en":"Drinking Water Laboratory – Tests","regulatory_area_zh":"饮用水实验室 – 检测","regulatory_area_cs":"Laboratoř pitných vod – Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Woda pitna Oznaczanie bakterii z grupy coli, Escherichia coli metodą Colilert metoda Colilert Voda pitná Stanovení koliformních bakterií, Escherichia coli metodou Colilert metodou Colilert SOP-P-52a/KB, EC (ČSN EN ISO 9308-2) Woda pitna Oznaczanie bakterii z grupy coli, Escherichia coli metoda Colilert metoda Colilert Voda pitna Stanoveni koliformnich bakterii, Escherichia coli metodou Colilert metodou Colilert SOP-P-52a/KB, EC (CSN EN ISO 9308-2)","search_en":"Drinking water Enumeration of coliform bacteria, Escherichia coli by Colilert method Colilert method SOP-P-52a/KB, EC (ČSN EN ISO 9308-2)","search_zh":"饮用水 Colilert法测定大肠菌群、大肠埃希氏菌 Colilert法 SOP-P-52a/KB, EC (ČSN EN ISO 9308-2)","categories":["water","microbiology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":65,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"82ec8105bd6b6538d86bb224","lab_id":"69ad52a4de79e566650fd2e2","country":"CZ","accr_number":"1202","accr_body":"ČIA","row_label":"22","test_object":"Woda pitna, surowa (powierzchniowa, podziemna), użytkowa","test_object_en":"Drinking water, raw water (surface, ground), service water","test_object_zh":"饮用水、原水（地表水、地下水）、杂用水","test_object_cs":"Voda pitná, surová (povrchová, podzemní), užitková","methodology":"Oznaczanie liczby organizmów, organizmów żywych metodą mikroskopową","methodology_en":"Determination of the number of organisms, living organisms by microscopy","methodology_zh":"显微镜法测定生物数量和活体生物数量","methodology_cs":"Stanovení počtu organismů, živých organismů mikroskopicky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"metoda mikroskopowa","technique_en":"by microscopy","technique_zh":"显微镜法","technique_cs":"mikroskopicky","techniques":["metoda mikroskopowa"],"techniques_en":["by microscopy"],"techniques_zh":["显微镜法"],"techniques_cs":["mikroskopicky"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie liczby organizmów, organizmów żywych metodą mikroskopową\nmetoda mikroskopowa","reference":"SOP-P-53/BR-PO, ŽO (ČSN 75 7712)","norm_bases":["SOP-P-53/BR-PO, ŽO","ČSN 75 7712"],"lab_section":"Laboratorium wód pitnych","lab_section_en":"Drinking Water Laboratory","lab_section_zh":"饮用水实验室","lab_section_cs":"Laboratoř pitných vod","lab_address":"Malostranská 143/2, Doudlevce, 326 00 Plzeň","regulatory_area":"Laboratorium wód pitnych – Badania","regulatory_area_en":"Drinking Water Laboratory – Tests","regulatory_area_zh":"饮用水实验室 – 检测","regulatory_area_cs":"Laboratoř pitných vod – Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Woda pitna, surowa (powierzchniowa, podziemna), użytkowa Oznaczanie liczby organizmów, organizmów żywych metodą mikroskopową metoda mikroskopowa Voda pitná, surová (povrchová, podzemní), užitková Stanovení počtu organismů, živých organismů mikroskopicky mikroskopicky SOP-P-53/BR-PO, ŽO (ČSN 75 7712) Woda pitna, surowa (powierzchniowa, podziemna), uzytkowa Oznaczanie liczby organizmow, organizmow zywych metoda mikroskopowa metoda mikroskopowa Voda pitna, surova (povrchova, podzemni), uzitkova Stanoveni poctu organismu, zivych organismu mikroskopicky mikroskopicky SOP-P-53/BR-PO, ZO (CSN 75 7712)","search_en":"Drinking water, raw water (surface, ground), service water Determination of the number of organisms, living organisms by microscopy by microscopy SOP-P-53/BR-PO, ŽO (ČSN 75 7712)","search_zh":"饮用水、原水（地表水、地下水）、杂用水 显微镜法测定生物数量和活体生物数量 显微镜法 SOP-P-53/BR-PO, ŽO (ČSN 75 7712)","categories":["water","microbiology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":66,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"e763b546b2490c68c33dea28","lab_id":"69ad52a4de79e566650fd2e2","country":"CZ","accr_number":"1202","accr_body":"ČIA","row_label":"23","test_object":"Woda pitna, surowa (powierzchniowa, podziemna), użytkowa","test_object_en":"Drinking water, raw water (surface, ground), service water","test_object_zh":"饮用水、原水（地表水、地下水）、杂用水","test_object_cs":"Voda pitná, surová (povrchová, podzemní), užitková","methodology":"Oznaczanie abiosestonu metodą mikroskopową","methodology_en":"Determination of abioseston by microscopy","methodology_zh":"显微镜法测定非生物悬浮物","methodology_cs":"Stanovení abiosestonu mikroskopicky","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"metoda mikroskopowa","technique_en":"by microscopy","technique_zh":"显微镜法","technique_cs":"mikroskopicky","techniques":["metoda mikroskopowa"],"techniques_en":["by microscopy"],"techniques_zh":["显微镜法"],"techniques_cs":["mikroskopicky"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie abiosestonu metodą mikroskopową\nmetoda mikroskopowa","reference":"SOP-P-54/abioseston (ČSN 75 7713)","norm_bases":["SOP-P-54/abioseston","ČSN 75 7713"],"lab_section":"Laboratorium wód pitnych","lab_section_en":"Drinking Water Laboratory","lab_section_zh":"饮用水实验室","lab_section_cs":"Laboratoř pitných vod","lab_address":"Malostranská 143/2, Doudlevce, 326 00 Plzeň","regulatory_area":"Laboratorium wód pitnych – Badania","regulatory_area_en":"Drinking Water Laboratory – Tests","regulatory_area_zh":"饮用水实验室 – 检测","regulatory_area_cs":"Laboratoř pitných vod – Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Woda pitna, surowa (powierzchniowa, podziemna), użytkowa Oznaczanie abiosestonu metodą mikroskopową metoda mikroskopowa Voda pitná, surová (povrchová, podzemní), užitková Stanovení abiosestonu mikroskopicky mikroskopicky SOP-P-54/abioseston (ČSN 75 7713) Woda pitna, surowa (powierzchniowa, podziemna), uzytkowa Oznaczanie abiosestonu metoda mikroskopowa metoda mikroskopowa Voda pitna, surova (povrchova, podzemni), uzitkova Stanoveni abiosestonu mikroskopicky mikroskopicky SOP-P-54/abioseston (CSN 75 7713)","search_en":"Drinking water, raw water (surface, ground), service water Determination of abioseston by microscopy by microscopy SOP-P-54/abioseston (ČSN 75 7713)","search_zh":"饮用水、原水（地表水、地下水）、杂用水 显微镜法测定非生物悬浮物 显微镜法 SOP-P-54/abioseston (ČSN 75 7713)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":67,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"569ea808796b419304424b10","lab_id":"69ad52a4de79e566650fd2e2","country":"CZ","accr_number":"1202","accr_body":"ČIA","row_label":"24","test_object":"Woda pitna, surowa (powierzchniowa, podziemna), użytkowa","test_object_en":"Drinking water, raw water (surface, ground), service water","test_object_zh":"饮用水、原水（地表水、地下水）、杂用水","test_object_cs":"Voda pitná, surová (povrchová, podzemní), užitková","methodology":"Oznaczanie bakterii termotolerancyjnych, Escherichia coli metodą filtracji membranowej","methodology_en":"Enumeration of thermotolerant bacteria, Escherichia coli by membrane filtration","methodology_zh":"膜过滤法测定耐热菌、大肠埃希氏菌","methodology_cs":"Stanovení termotolerantních bakterií, Escherichia coli membránovou filtrací","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"filtracja membranowa","technique_en":"membrane filtration","technique_zh":"膜过滤法","technique_cs":"membránovou filtrací","techniques":["filtracja membranowa"],"techniques_en":["membrane filtration"],"techniques_zh":["膜过滤法"],"techniques_cs":["membránovou filtrací"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie bakterii termotolerancyjnych, Escherichia coli metodą filtracji membranowej\nfiltracja membranowa","reference":"SOP-P-55/FB, EC (ČSN 75 7835)","norm_bases":["SOP-P-55/FB, EC","ČSN 75 7835"],"lab_section":"Laboratorium wód pitnych","lab_section_en":"Drinking Water Laboratory","lab_section_zh":"饮用水实验室","lab_section_cs":"Laboratoř pitných vod","lab_address":"Malostranská 143/2, Doudlevce, 326 00 Plzeň","regulatory_area":"Laboratorium wód pitnych – Badania","regulatory_area_en":"Drinking Water Laboratory – Tests","regulatory_area_zh":"饮用水实验室 – 检测","regulatory_area_cs":"Laboratoř pitných vod – Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Woda pitna, surowa (powierzchniowa, podziemna), użytkowa Oznaczanie bakterii termotolerancyjnych, Escherichia coli metodą filtracji membranowej filtracja membranowa Voda pitná, surová (povrchová, podzemní), užitková Stanovení termotolerantních bakterií, Escherichia coli membránovou filtrací membránovou filtrací SOP-P-55/FB, EC (ČSN 75 7835) Woda pitna, surowa (powierzchniowa, podziemna), uzytkowa Oznaczanie bakterii termotolerancyjnych, Escherichia coli metoda filtracji membranowej filtracja membranowa Voda pitna, surova (povrchova, podzemni), uzitkova Stanoveni termotolerantnich bakterii, Escherichia coli membranovou filtraci membranovou filtraci SOP-P-55/FB, EC (CSN 75 7835)","search_en":"Drinking water, raw water (surface, ground), service water Enumeration of thermotolerant bacteria, Escherichia coli by membrane filtration membrane filtration SOP-P-55/FB, EC (ČSN 75 7835)","search_zh":"饮用水、原水（地表水、地下水）、杂用水 膜过滤法测定耐热菌、大肠埃希氏菌 膜过滤法 SOP-P-55/FB, EC (ČSN 75 7835)","categories":["water","microbiology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":68,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"e68125cd061f014f9bd071f0","lab_id":"69ad52a4de79e566650fd2e2","country":"CZ","accr_number":"1202","accr_body":"ČIA","row_label":"25","test_object":"Woda pitna, surowa (powierzchniowa, podziemna), użytkowa","test_object_en":"Drinking water, raw water (surface, ground), service water","test_object_zh":"饮用水、原水（地表水、地下水）、杂用水","test_object_cs":"Voda pitná, surová (povrchová, podzemní), užitková","methodology":"Oznaczanie bakterii z grupy coli metodą filtracji membranowej","methodology_en":"Enumeration of coliform bacteria by membrane filtration","methodology_zh":"膜过滤法测定大肠菌群","methodology_cs":"Stanovení koliformních bakterií membránovou filtrací","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"filtracja membranowa","technique_en":"membrane filtration","technique_zh":"膜过滤法","technique_cs":"membránovou filtrací","techniques":["filtracja membranowa"],"techniques_en":["membrane filtration"],"techniques_zh":["膜过滤法"],"techniques_cs":["membránovou filtrací"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie bakterii z grupy coli metodą filtracji membranowej\nfiltracja membranowa","reference":"SOP-P-56/KB (ČSN 75 7837)","norm_bases":["SOP-P-56/KB","ČSN 75 7837"],"lab_section":"Laboratorium wód pitnych","lab_section_en":"Drinking Water Laboratory","lab_section_zh":"饮用水实验室","lab_section_cs":"Laboratoř pitných vod","lab_address":"Malostranská 143/2, Doudlevce, 326 00 Plzeň","regulatory_area":"Laboratorium wód pitnych – Badania","regulatory_area_en":"Drinking Water Laboratory – Tests","regulatory_area_zh":"饮用水实验室 – 检测","regulatory_area_cs":"Laboratoř pitných vod – Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Woda pitna, surowa (powierzchniowa, podziemna), użytkowa Oznaczanie bakterii z grupy coli metodą filtracji membranowej filtracja membranowa Voda pitná, surová (povrchová, podzemní), užitková Stanovení koliformních bakterií membránovou filtrací membránovou filtrací SOP-P-56/KB (ČSN 75 7837) Woda pitna, surowa (powierzchniowa, podziemna), uzytkowa Oznaczanie bakterii z grupy coli metoda filtracji membranowej filtracja membranowa Voda pitna, surova (povrchova, podzemni), uzitkova Stanoveni koliformnich bakterii membranovou filtraci membranovou filtraci SOP-P-56/KB (CSN 75 7837)","search_en":"Drinking water, raw water (surface, ground), service water Enumeration of coliform bacteria by membrane filtration membrane filtration SOP-P-56/KB (ČSN 75 7837)","search_zh":"饮用水、原水（地表水、地下水）、杂用水 膜过滤法测定大肠菌群 膜过滤法 SOP-P-56/KB (ČSN 75 7837)","categories":["water","microbiology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":69,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"d5d6ca9d5b05af6de7ce05b1","lab_id":"69ad52a4de79e566650fd2e2","country":"CZ","accr_number":"1202","accr_body":"ČIA","row_label":"26","test_object":"Woda pitna, surowa (powierzchniowa, podziemna), użytkowa","test_object_en":"Drinking water, raw water (surface, ground), service water","test_object_zh":"饮用水、原水（地表水、地下水）、杂用水","test_object_cs":"Voda pitná, surová (povrchová, podzemní), užitková","methodology":"Oznaczanie enterokoków jelitowych metodą filtracji membranowej","methodology_en":"Enumeration of intestinal enterococci by membrane filtration","methodology_zh":"膜过滤法测定肠球菌","methodology_cs":"Stanovení intestinálních enterokoků membránovou filtrací","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"filtracja membranowa","technique_en":"membrane filtration","technique_zh":"膜过滤法","technique_cs":"membránovou filtrací","techniques":["filtracja membranowa"],"techniques_en":["membrane filtration"],"techniques_zh":["膜过滤法"],"techniques_cs":["membránovou filtrací"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie enterokoków jelitowych metodą filtracji membranowej\nfiltracja membranowa","reference":"SOP-P-57/E (ČSN EN ISO 7899-2)","norm_bases":["SOP-P-57/E","ČSN EN ISO 7899-2"],"lab_section":"Laboratorium wód pitnych","lab_section_en":"Drinking Water Laboratory","lab_section_zh":"饮用水实验室","lab_section_cs":"Laboratoř pitných vod","lab_address":"Malostranská 143/2, Doudlevce, 326 00 Plzeň","regulatory_area":"Laboratorium wód pitnych – Badania","regulatory_area_en":"Drinking Water Laboratory – Tests","regulatory_area_zh":"饮用水实验室 – 检测","regulatory_area_cs":"Laboratoř pitných vod – Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Woda pitna, surowa (powierzchniowa, podziemna), użytkowa Oznaczanie enterokoków jelitowych metodą filtracji membranowej filtracja membranowa Voda pitná, surová (povrchová, podzemní), užitková Stanovení intestinálních enterokoků membránovou filtrací membránovou filtrací SOP-P-57/E (ČSN EN ISO 7899-2) Woda pitna, surowa (powierzchniowa, podziemna), uzytkowa Oznaczanie enterokokow jelitowych metoda filtracji membranowej filtracja membranowa Voda pitna, surova (povrchova, podzemni), uzitkova Stanoveni intestinalnich enterokoku membranovou filtraci membranovou filtraci SOP-P-57/E (CSN EN ISO 7899-2)","search_en":"Drinking water, raw water (surface, ground), service water Enumeration of intestinal enterococci by membrane filtration membrane filtration SOP-P-57/E (ČSN EN ISO 7899-2)","search_zh":"饮用水、原水（地表水、地下水）、杂用水 膜过滤法测定肠球菌 膜过滤法 SOP-P-57/E (ČSN EN ISO 7899-2)","categories":["water","microbiology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":70,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"b83cbaf1c578a2a1249a23c4","lab_id":"69ad52a4de79e566650fd2e2","country":"CZ","accr_number":"1202","accr_body":"ČIA","row_label":"28","test_object":"Woda pitna, surowa (powierzchniowa, podziemna), użytkowa","test_object_en":"Drinking water, raw water (surface, ground), service water","test_object_zh":"饮用水、原水（地表水、地下水）、杂用水","test_object_cs":"Voda pitná, surová (povrchová, podzemní), užitková","methodology":"Oznaczanie drobnoustrojów hodowlanych w 36 °C metodą posiewu bezpośredniego na agarowe hodowlane podłoże odżywcze","methodology_en":"Enumeration of culturable microorganisms at 36 °C by direct plating on nutrient agar culture medium","methodology_zh":"营养琼脂培养基直接接种法计数36 °C可培养微生物","methodology_cs":"Stanovení kultivovatelných mikroorganismů 36 °C, metodou přímého výsevu do živného agarového kultivačního media","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"posiew bezpośredni na agarowe hodowlane podłoże odżywcze","technique_en":"direct plating on nutrient agar culture medium","technique_zh":"营养琼脂培养基直接接种法","technique_cs":"metodou přímého výsevu do živného agarového kultivačního media","techniques":["posiew bezpośredni na agarowe hodowlane podłoże odżywcze"],"techniques_en":["direct plating on nutrient agar culture medium"],"techniques_zh":["营养琼脂培养基直接接种法"],"techniques_cs":["metodou přímého výsevu do živného agarového kultivačního media"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie drobnoustrojów hodowlanych w 36 °C metodą posiewu bezpośredniego na agarowe hodowlane podłoże odżywcze\nposiew bezpośredni na agarowe hodowlane podłoże odżywcze","reference":"SOP-P-62/KM36 °C (ČSN EN ISO 6222)","norm_bases":["SOP-P-62/KM36 °C","ČSN EN ISO 6222"],"lab_section":"Laboratorium wód pitnych","lab_section_en":"Drinking Water Laboratory","lab_section_zh":"饮用水实验室","lab_section_cs":"Laboratoř pitných vod","lab_address":"Malostranská 143/2, Doudlevce, 326 00 Plzeň","regulatory_area":"Laboratorium wód pitnych – Badania","regulatory_area_en":"Drinking Water Laboratory – Tests","regulatory_area_zh":"饮用水实验室 – 检测","regulatory_area_cs":"Laboratoř pitných vod – Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Woda pitna, surowa (powierzchniowa, podziemna), użytkowa Oznaczanie drobnoustrojów hodowlanych w 36 °C metodą posiewu bezpośredniego na agarowe hodowlane podłoże odżywcze posiew bezpośredni na agarowe hodowlane podłoże odżywcze Voda pitná, surová (povrchová, podzemní), užitková Stanovení kultivovatelných mikroorganismů 36 °C, metodou přímého výsevu do živného agarového kultivačního media metodou přímého výsevu do živného agarového kultivačního media SOP-P-62/KM36 °C (ČSN EN ISO 6222) Woda pitna, surowa (powierzchniowa, podziemna), uzytkowa Oznaczanie drobnoustrojow hodowlanych w 36 °C metoda posiewu bezposredniego na agarowe hodowlane podloze odzywcze posiew bezposredni na agarowe hodowlane podloze odzywcze Voda pitna, surova (povrchova, podzemni), uzitkova Stanoveni kultivovatelnych mikroorganismu 36 °C, metodou primeho vysevu do zivneho agaroveho kultivacniho media metodou primeho vysevu do zivneho agaroveho kultivacniho media SOP-P-62/KM36 °C (CSN EN ISO 6222)","search_en":"Drinking water, raw water (surface, ground), service water Enumeration of culturable microorganisms at 36 °C by direct plating on nutrient agar culture medium direct plating on nutrient agar culture medium SOP-P-62/KM36 °C (ČSN EN ISO 6222)","search_zh":"饮用水、原水（地表水、地下水）、杂用水 营养琼脂培养基直接接种法计数36 °C可培养微生物 营养琼脂培养基直接接种法 SOP-P-62/KM36 °C (ČSN EN ISO 6222)","categories":["water","microbiology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":71,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"55bc03720eac0c3a5dbcba1a","lab_id":"69ad52a4de79e566650fd2e2","country":"CZ","accr_number":"1202","accr_body":"ČIA","row_label":"29","test_object":"Woda pitna, surowa (powierzchniowa, podziemna), użytkowa i ścieki","test_object_en":"Drinking water, raw water (surface, ground), service and waste water","test_object_zh":"饮用水、原水（地表水、地下水）、杂用水和废水","test_object_cs":"Voda pitná, surová (povrchová, podzemní), užitková a odpadní","methodology":"Oznaczanie temperatury (t)","methodology_en":"Determination of temperature (t)","methodology_zh":"温度的测定（t）","methodology_cs":"Stanovení teploty (t)","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie temperatury (t)","reference":"SOP-03/teplota část A (ČSN 75 7342)","norm_bases":["SOP-03/teplota část A","ČSN 75 7342"],"lab_section":"Laboratorium wód pitnych","lab_section_en":"Drinking Water Laboratory","lab_section_zh":"饮用水实验室","lab_section_cs":"Laboratoř pitných vod","lab_address":"Malostranská 143/2, Doudlevce, 326 00 Plzeň","regulatory_area":"Laboratorium wód pitnych – Badania","regulatory_area_en":"Drinking Water Laboratory – Tests","regulatory_area_zh":"饮用水实验室 – 检测","regulatory_area_cs":"Laboratoř pitných vod – Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Woda pitna, surowa (powierzchniowa, podziemna), użytkowa i ścieki Oznaczanie temperatury (t) Voda pitná, surová (povrchová, podzemní), užitková a odpadní Stanovení teploty (t) SOP-03/teplota část A (ČSN 75 7342) Woda pitna, surowa (powierzchniowa, podziemna), uzytkowa i scieki Oznaczanie temperatury (t) Voda pitna, surova (povrchova, podzemni), uzitkova a odpadni Stanoveni teploty (t) SOP-03/teplota cast A (CSN 75 7342)","search_en":"Drinking water, raw water (surface, ground), service and waste water Determination of temperature (t) SOP-03/teplota část A (ČSN 75 7342)","search_zh":"饮用水、原水（地表水、地下水）、杂用水和废水 温度的测定（t） SOP-03/teplota část A (ČSN 75 7342)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":72,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"8107b5c6cc523de0b1de35a2","lab_id":"69ad52a4de79e566650fd2e2","country":"CZ","accr_number":"1202","accr_body":"ČIA","row_label":"30","test_object":"Osad","test_object_en":"Sludge","test_object_zh":"污泥","test_object_cs":"Kal","methodology":"Oznaczanie temperatury (t)","methodology_en":"Determination of temperature (t)","methodology_zh":"温度的测定（t）","methodology_cs":"Stanovení teploty (t)","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie temperatury (t)","reference":"SOP-03/teplota část B (ČSN 75 7342)","norm_bases":["SOP-03/teplota část B","ČSN 75 7342"],"lab_section":"Laboratorium wód pitnych","lab_section_en":"Drinking Water Laboratory","lab_section_zh":"饮用水实验室","lab_section_cs":"Laboratoř pitných vod","lab_address":"Malostranská 143/2, Doudlevce, 326 00 Plzeň","regulatory_area":"Laboratorium wód pitnych – Badania","regulatory_area_en":"Drinking Water Laboratory – Tests","regulatory_area_zh":"饮用水实验室 – 检测","regulatory_area_cs":"Laboratoř pitných vod – Zkoušky","flexible":true,"flexibility":"A","outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Osad Oznaczanie temperatury (t) Kal Stanovení teploty (t) SOP-03/teplota část B (ČSN 75 7342) Osad Oznaczanie temperatury (t) Kal Stanoveni teploty (t) SOP-03/teplota cast B (CSN 75 7342)","search_en":"Sludge Determination of temperature (t) SOP-03/teplota část B (ČSN 75 7342)","search_zh":"污泥 温度的测定（t） SOP-03/teplota část B (ČSN 75 7342)","categories":["environment"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":73,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"2e1cfc2915d2d49c21165f60","lab_id":"69ad52a4de79e566650fd2e2","country":"CZ","accr_number":"1202","accr_body":"ČIA","row_label":"31","test_object":"Woda pitna, surowa (powierzchniowa, podziemna), użytkowa","test_object_en":"Drinking water, raw water (surface, ground), service water","test_object_zh":"饮用水、原水（地表水、地下水）、杂用水","test_object_cs":"Voda pitná, surová (povrchová, podzemní), užitková","methodology":"Oznaczanie chloru wolnego i ogólnego metodą spektrometryczną z użyciem zestawu firmy HACH (Cl2), chloru związanego obliczeniowo z wartości zmierzonych","methodology_en":"Determination of free and total chlorine by spectrometry using a HACH kit (Cl2), combined chlorine by calculation from measured values","methodology_zh":"使用HACH试剂盒光谱法测定游离氯和总氯（Cl2），并由测量值计算化合氯","methodology_cs":"Stanovení volného a celkového chloru spektrometricky s využitím setu firmy HACH (Cl2), vázaného chloru výpočtem z naměřených hodnot","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"spektrometria, zestaw firmy HACH","technique_en":"spectrometry using a HACH kit","technique_zh":"光谱法（HACH试剂盒）","technique_cs":"spektrometricky s využitím setu firmy HACH","techniques":["spektrometria, zestaw firmy HACH"],"techniques_en":["spectrometry using a HACH kit"],"techniques_zh":["光谱法（HACH试剂盒）"],"techniques_cs":["spektrometricky s využitím setu firmy HACH"],"computed":["chlor związany (obliczeniowo z wartości zmierzonych)"],"computed_en":["combined chlorine by calculation from measured values"],"computed_zh":["化合氯（由测量值计算）"],"computed_cs":["vázaného chloru výpočtem z naměřených hodnot"],"activity":"Oznaczanie chloru wolnego i ogólnego metodą spektrometryczną z użyciem zestawu firmy HACH (Cl2), chloru związanego obliczeniowo z wartości zmierzonych\nspektrometria, zestaw firmy HACH","reference":"SOP-37/Cl2 (ČSN EN ISO 7393-2)","norm_bases":["SOP-37/Cl2","ČSN EN ISO 7393-2"],"lab_section":"Laboratorium wód pitnych","lab_section_en":"Drinking Water Laboratory","lab_section_zh":"饮用水实验室","lab_section_cs":"Laboratoř pitných vod","lab_address":"Malostranská 143/2, Doudlevce, 326 00 Plzeň","regulatory_area":"Laboratorium wód pitnych – Badania","regulatory_area_en":"Drinking Water Laboratory – Tests","regulatory_area_zh":"饮用水实验室 – 检测","regulatory_area_cs":"Laboratoř pitných vod – Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Woda pitna, surowa (powierzchniowa, podziemna), użytkowa Oznaczanie chloru wolnego i ogólnego metodą spektrometryczną z użyciem zestawu firmy HACH (Cl2), chloru związanego obliczeniowo z wartości zmierzonych spektrometria, zestaw firmy HACH chlor związany (obliczeniowo z wartości zmierzonych) Voda pitná, surová (povrchová, podzemní), užitková Stanovení volného a celkového chloru spektrometricky s využitím setu firmy HACH (Cl2), vázaného chloru výpočtem z naměřených hodnot spektrometricky s využitím setu firmy HACH vázaného chloru výpočtem z naměřených hodnot SOP-37/Cl2 (ČSN EN ISO 7393-2) Woda pitna, surowa (powierzchniowa, podziemna), uzytkowa Oznaczanie chloru wolnego i ogolnego metoda spektrometryczna z uzyciem zestawu firmy HACH (Cl2), chloru zwiazanego obliczeniowo z wartosci zmierzonych spektrometria, zestaw firmy HACH chlor zwiazany (obliczeniowo z wartosci zmierzonych) Voda pitna, surova (povrchova, podzemni), uzitkova Stanoveni volneho a celkoveho chloru spektrometricky s vyuzitim setu firmy HACH (Cl2), vazaneho chloru vypoctem z namerenych hodnot spektrometricky s vyuzitim setu firmy HACH vazaneho chloru vypoctem z namerenych hodnot SOP-37/Cl2 (CSN EN ISO 7393-2)","search_en":"Drinking water, raw water (surface, ground), service water Determination of free and total chlorine by spectrometry using a HACH kit (Cl2), combined chlorine by calculation from measured values spectrometry using a HACH kit combined chlorine by calculation from measured values SOP-37/Cl2 (ČSN EN ISO 7393-2)","search_zh":"饮用水、原水（地表水、地下水）、杂用水 使用HACH试剂盒光谱法测定游离氯和总氯（Cl2），并由测量值计算化合氯 光谱法（HACH试剂盒） 化合氯（由测量值计算） SOP-37/Cl2 (ČSN EN ISO 7393-2)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":74,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"c9ba2689311666a86908a9c7","lab_id":"69ad52a4de79e566650fd2e2","country":"CZ","accr_number":"1202","accr_body":"ČIA","row_label":"32","test_object":"Woda pitna o niskiej zawartości mikroflory towarzyszącej","test_object_en":"Drinking water with low background microflora","test_object_zh":"伴生菌群含量低的饮用水","test_object_cs":"Pitná voda s nízkým obsahem doprovodné mikroflóry","methodology":"Oznaczanie bakterii z grupy coli, Escherichia coli metodą filtracji membranowej","methodology_en":"Enumeration of coliform bacteria, Escherichia coli by membrane filtration","methodology_zh":"膜过滤法测定大肠菌群、大肠埃希氏菌","methodology_cs":"Stanovení koliformních bakterií, Escherichia coli membránovou filtrací","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"filtracja membranowa","technique_en":"membrane filtration","technique_zh":"膜过滤法","technique_cs":"membránovou filtrací","techniques":["filtracja membranowa"],"techniques_en":["membrane filtration"],"techniques_zh":["膜过滤法"],"techniques_cs":["membránovou filtrací"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie bakterii z grupy coli, Escherichia coli metodą filtracji membranowej\nfiltracja membranowa","reference":"SOP-P-52b/KB, EC (ČSN EN ISO 9308-1)","norm_bases":["SOP-P-52b/KB, EC","ČSN EN ISO 9308-1"],"lab_section":"Laboratorium wód pitnych","lab_section_en":"Drinking Water Laboratory","lab_section_zh":"饮用水实验室","lab_section_cs":"Laboratoř pitných vod","lab_address":"Malostranská 143/2, Doudlevce, 326 00 Plzeň","regulatory_area":"Laboratorium wód pitnych – Badania","regulatory_area_en":"Drinking Water Laboratory – Tests","regulatory_area_zh":"饮用水实验室 – 检测","regulatory_area_cs":"Laboratoř pitných vod – Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Woda pitna o niskiej zawartości mikroflory towarzyszącej Oznaczanie bakterii z grupy coli, Escherichia coli metodą filtracji membranowej filtracja membranowa Pitná voda s nízkým obsahem doprovodné mikroflóry Stanovení koliformních bakterií, Escherichia coli membránovou filtrací membránovou filtrací SOP-P-52b/KB, EC (ČSN EN ISO 9308-1) Woda pitna o niskiej zawartosci mikroflory towarzyszacej Oznaczanie bakterii z grupy coli, Escherichia coli metoda filtracji membranowej filtracja membranowa Pitna voda s nizkym obsahem doprovodne mikroflory Stanoveni koliformnich bakterii, Escherichia coli membranovou filtraci membranovou filtraci SOP-P-52b/KB, EC (CSN EN ISO 9308-1)","search_en":"Drinking water with low background microflora Enumeration of coliform bacteria, Escherichia coli by membrane filtration membrane filtration SOP-P-52b/KB, EC (ČSN EN ISO 9308-1)","search_zh":"伴生菌群含量低的饮用水 膜过滤法测定大肠菌群、大肠埃希氏菌 膜过滤法 SOP-P-52b/KB, EC (ČSN EN ISO 9308-1)","categories":["water","microbiology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":75,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"c4eb44eab68f865f1fd828eb","lab_id":"69ad52a4de79e566650fd2e2","country":"CZ","accr_number":"1202","accr_body":"ČIA","row_label":"34","test_object":"Woda pitna, surowa (powierzchniowa, podziemna), użytkowa","test_object_en":"Drinking water, raw water (surface, ground), service water","test_object_zh":"饮用水、原水（地表水、地下水）、杂用水","test_object_cs":"Voda pitná, surová (povrchová, podzemní), užitková","methodology":"Oznaczanie Clostridium perfringens metodą filtracji membranowej","methodology_en":"Enumeration of Clostridium perfringens by membrane filtration","methodology_zh":"膜过滤法测定产气荚膜梭菌","methodology_cs":"Stanovení Clostridium perfringens membránovou filtrací","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"filtracja membranowa","technique_en":"membrane filtration","technique_zh":"膜过滤法","technique_cs":"membránovou filtrací","techniques":["filtracja membranowa"],"techniques_en":["membrane filtration"],"techniques_zh":["膜过滤法"],"techniques_cs":["membránovou filtrací"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie Clostridium perfringens metodą filtracji membranowej\nfiltracja membranowa","reference":"SOP-P-58a/CP (ČSN EN ISO 14189)","norm_bases":["SOP-P-58a/CP","ČSN EN ISO 14189"],"lab_section":"Laboratorium wód pitnych","lab_section_en":"Drinking Water Laboratory","lab_section_zh":"饮用水实验室","lab_section_cs":"Laboratoř pitných vod","lab_address":"Malostranská 143/2, Doudlevce, 326 00 Plzeň","regulatory_area":"Laboratorium wód pitnych – Badania","regulatory_area_en":"Drinking Water Laboratory – Tests","regulatory_area_zh":"饮用水实验室 – 检测","regulatory_area_cs":"Laboratoř pitných vod – Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Woda pitna, surowa (powierzchniowa, podziemna), użytkowa Oznaczanie Clostridium perfringens metodą filtracji membranowej filtracja membranowa Voda pitná, surová (povrchová, podzemní), užitková Stanovení Clostridium perfringens membránovou filtrací membránovou filtrací SOP-P-58a/CP (ČSN EN ISO 14189) Woda pitna, surowa (powierzchniowa, podziemna), uzytkowa Oznaczanie Clostridium perfringens metoda filtracji membranowej filtracja membranowa Voda pitna, surova (povrchova, podzemni), uzitkova Stanoveni Clostridium perfringens membranovou filtraci membranovou filtraci SOP-P-58a/CP (CSN EN ISO 14189)","search_en":"Drinking water, raw water (surface, ground), service water Enumeration of Clostridium perfringens by membrane filtration membrane filtration SOP-P-58a/CP (ČSN EN ISO 14189)","search_zh":"饮用水、原水（地表水、地下水）、杂用水 膜过滤法测定产气荚膜梭菌 膜过滤法 SOP-P-58a/CP (ČSN EN ISO 14189)","categories":["water","microbiology"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":76,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"8bf401f89b02cc8af575578a","lab_id":"69ad52a4de79e566650fd2e2","country":"CZ","accr_number":"1202","accr_body":"ČIA","row_label":"35","test_object":"Woda pitna, surowa (powierzchniowa, podziemna), użytkowa","test_object_en":"Drinking water, raw water (surface, ground), service water","test_object_zh":"饮用水、原水（地表水、地下水）、杂用水","test_object_cs":"Voda pitná, surová (povrchová, podzemní), užitková","methodology":"Oznaczanie leków metodą LC/MS/MS (LEC)","methodology_en":"Determination of pharmaceuticals by LC/MS/MS method (LEC)","methodology_zh":"液相色谱-串联质谱法测定药物（LEC）","methodology_cs":"Stanovení léčiv metodou LC/MS/MS (LEC)","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"LC-MS/MS","technique_en":"LC/MS/MS method","technique_zh":"液相色谱-串联质谱法（LC/MS/MS）","technique_cs":"metodou LC/MS/MS","techniques":["LC-MS/MS"],"techniques_en":["LC/MS/MS method"],"techniques_zh":["液相色谱-串联质谱法（LC/MS/MS）"],"techniques_cs":["metodou LC/MS/MS"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie leków metodą LC/MS/MS (LEC)\nLC-MS/MS","reference":"SOP-P-90/analyty LC MS, LC - 91/LEC ESI+ (ČSN EN ISO 21676)","norm_bases":["SOP-P-90/analyty LC MS, LC - 91/LEC ESI+","ČSN EN ISO 21676"],"lab_section":"Laboratorium wód pitnych","lab_section_en":"Drinking Water Laboratory","lab_section_zh":"饮用水实验室","lab_section_cs":"Laboratoř pitných vod","lab_address":"Malostranská 143/2, Doudlevce, 326 00 Plzeň","regulatory_area":"Laboratorium wód pitnych – Badania","regulatory_area_en":"Drinking Water Laboratory – Tests","regulatory_area_zh":"饮用水实验室 – 检测","regulatory_area_cs":"Laboratoř pitných vod – Zkoušky","flexible":true,"flexibility":"B","outside_premises":false,"note":"Oznaczane anality: klarytromycyna, diklofenak, gabapentyna, karbamazepina, metformina, oksypurynol, tramadol","note_en":"Determined analytes: Clarithromycin, Diclofenac, Gabapentin, Carbamazepine, Metformin, Oxypurinol, Tramadol","note_zh":"测定的分析物：克拉霉素、双氯芬酸、加巴喷丁、卡马西平、二甲双胍、氧嘌呤醇、曲马多","note_cs":"Stanovované analyty: Clarithromycin, Diclofenac, Gabapentin, Carbamazepine, Metformin, Oxypurinol, Tramadol","search_text":"Woda pitna, surowa (powierzchniowa, podziemna), użytkowa Oznaczanie leków metodą LC/MS/MS (LEC) LC-MS/MS Voda pitná, surová (povrchová, podzemní), užitková Stanovení léčiv metodou LC/MS/MS (LEC) metodou LC/MS/MS SOP-P-90/analyty LC MS, LC - 91/LEC ESI+ (ČSN EN ISO 21676) Woda pitna, surowa (powierzchniowa, podziemna), uzytkowa Oznaczanie lekow metoda LC/MS/MS (LEC) LC-MS/MS Voda pitna, surova (povrchova, podzemni), uzitkova Stanoveni leciv metodou LC/MS/MS (LEC) metodou LC/MS/MS SOP-P-90/analyty LC MS, LC - 91/LEC ESI+ (CSN EN ISO 21676)","search_en":"Drinking water, raw water (surface, ground), service water Determination of pharmaceuticals by LC/MS/MS method (LEC) LC/MS/MS method SOP-P-90/analyty LC MS, LC - 91/LEC ESI+ (ČSN EN ISO 21676)","search_zh":"饮用水、原水（地表水、地下水）、杂用水 液相色谱-串联质谱法测定药物（LEC） 液相色谱-串联质谱法（LC/MS/MS） SOP-P-90/analyty LC MS, LC - 91/LEC ESI+ (ČSN EN ISO 21676)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":77,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"5ea44e3c2b1d7323d78b207f","lab_id":"69ad52a4de79e566650fd2e2","country":"CZ","accr_number":"1202","accr_body":"ČIA","row_label":"36","test_object":"Woda pitna, surowa (powierzchniowa, podziemna), użytkowa","test_object_en":"Drinking water, raw water (surface, ground), service water","test_object_zh":"饮用水、原水（地表水、地下水）、杂用水","test_object_cs":"Voda pitná, surová (povrchová, podzemní), užitková","methodology":"Oznaczanie leków metodą LC/MS/MS (LEC)","methodology_en":"Determination of pharmaceuticals by LC/MS/MS method (LEC)","methodology_zh":"液相色谱-串联质谱法测定药物（LEC）","methodology_cs":"Stanovení léčiv metodou LC/MS/MS (LEC)","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"LC-MS/MS","technique_en":"LC/MS/MS method","technique_zh":"液相色谱-串联质谱法（LC/MS/MS）","technique_cs":"metodou LC/MS/MS","techniques":["LC-MS/MS"],"techniques_en":["LC/MS/MS method"],"techniques_zh":["液相色谱-串联质谱法（LC/MS/MS）"],"techniques_cs":["metodou LC/MS/MS"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie leków metodą LC/MS/MS (LEC)\nLC-MS/MS","reference":"SOP-P-90/analyty LC MS, LC - 91/LEC ESI- (ČSN EN ISO 21676)","norm_bases":["SOP-P-90/analyty LC MS, LC - 91/LEC ESI-","ČSN EN ISO 21676"],"lab_section":"Laboratorium wód pitnych","lab_section_en":"Drinking Water Laboratory","lab_section_zh":"饮用水实验室","lab_section_cs":"Laboratoř pitných vod","lab_address":"Malostranská 143/2, Doudlevce, 326 00 Plzeň","regulatory_area":"Laboratorium wód pitnych – Badania","regulatory_area_en":"Drinking Water Laboratory – Tests","regulatory_area_zh":"饮用水实验室 – 检测","regulatory_area_cs":"Laboratoř pitných vod – Zkoušky","flexible":true,"flexibility":"B","outside_premises":false,"note":"Oznaczane anality: ibuprofen, 2-hydroksyibuprofen, karboksyibuprofen","note_en":"Determined analytes: Ibuprofen, 2-hydroxyibuprofen, carboxyibuprofen","note_zh":"测定的分析物：布洛芬、2-羟基布洛芬、羧基布洛芬","note_cs":"Stanovované analyty: Ibuprofen, Ibuprofen 2 hydroxy, Ibuprofen carboxy","search_text":"Woda pitna, surowa (powierzchniowa, podziemna), użytkowa Oznaczanie leków metodą LC/MS/MS (LEC) LC-MS/MS Voda pitná, surová (povrchová, podzemní), užitková Stanovení léčiv metodou LC/MS/MS (LEC) metodou LC/MS/MS SOP-P-90/analyty LC MS, LC - 91/LEC ESI- (ČSN EN ISO 21676) Woda pitna, surowa (powierzchniowa, podziemna), uzytkowa Oznaczanie lekow metoda LC/MS/MS (LEC) LC-MS/MS Voda pitna, surova (povrchova, podzemni), uzitkova Stanoveni leciv metodou LC/MS/MS (LEC) metodou LC/MS/MS SOP-P-90/analyty LC MS, LC - 91/LEC ESI- (CSN EN ISO 21676)","search_en":"Drinking water, raw water (surface, ground), service water Determination of pharmaceuticals by LC/MS/MS method (LEC) LC/MS/MS method SOP-P-90/analyty LC MS, LC - 91/LEC ESI- (ČSN EN ISO 21676)","search_zh":"饮用水、原水（地表水、地下水）、杂用水 液相色谱-串联质谱法测定药物（LEC） 液相色谱-串联质谱法（LC/MS/MS） SOP-P-90/analyty LC MS, LC - 91/LEC ESI- (ČSN EN ISO 21676)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":78,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"5db70d738206d71e684da3ce","lab_id":"69ad52a4de79e566650fd2e2","country":"CZ","accr_number":"1202","accr_body":"ČIA","row_label":"1","test_object":"Woda pitna, woda surowa powierzchniowa do produkcji wody pitnej","test_object_en":"Drinking water, raw surface water for drinking water production","test_object_zh":"饮用水、用于生产饮用水的原地表水","test_object_cs":"Pitná voda, surová voda povrchová pro výrobu pitné vody","methodology":"Pobieranie próbek wód","methodology_en":"Water sampling","methodology_zh":"水样采样","methodology_cs":"Odběr vzorků vod","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pobieranie próbek wód","reference":"SOP-500/odběr A (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN EN ISO 5667-16; ČSN ISO 5667-5; ČSN EN ISO 5667-14; ČSN EN ISO 19458; Vyhláška č. 252/2004 Sb.)","norm_bases":["SOP-500/odběr A","ČSN EN ISO 5667-1","ČSN EN ISO 5667-3","ČSN EN ISO 5667-16","ČSN ISO 5667-5","ČSN EN ISO 5667-14","ČSN EN ISO 19458","Vyhláška č. 252/2004 Sb."],"lab_section":"Laboratorium wód pitnych","lab_section_en":"Drinking Water Laboratory","lab_section_zh":"饮用水实验室","lab_section_cs":"Laboratoř pitných vod","lab_address":"Malostranská 143/2, Doudlevce, 326 00 Plzeň","regulatory_area":"Laboratorium wód pitnych – Pobieranie próbek","regulatory_area_en":"Drinking Water Laboratory – Sampling","regulatory_area_zh":"饮用水实验室 – 采样","regulatory_area_cs":"Laboratoř pitných vod – Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Woda pitna, woda surowa powierzchniowa do produkcji wody pitnej Pobieranie próbek wód Pitná voda, surová voda povrchová pro výrobu pitné vody Odběr vzorků vod SOP-500/odběr A (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN EN ISO 5667-16; ČSN ISO 5667-5; ČSN EN ISO 5667-14; ČSN EN ISO 19458; Vyhláška č. 252/2004 Sb.) Woda pitna, woda surowa powierzchniowa do produkcji wody pitnej Pobieranie probek wod Pitna voda, surova voda povrchova pro vyrobu pitne vody Odber vzorku vod SOP-500/odber A (CSN EN ISO 5667-1; CSN EN ISO 5667-3; CSN EN ISO 5667-16; CSN ISO 5667-5; CSN EN ISO 5667-14; CSN EN ISO 19458; Vyhlaska c. 252/2004 Sb.)","search_en":"Drinking water, raw surface water for drinking water production Water sampling SOP-500/odběr A (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN EN ISO 5667-16; ČSN ISO 5667-5; ČSN EN ISO 5667-14; ČSN EN ISO 19458; Vyhláška č. 252/2004 Sb.)","search_zh":"饮用水、用于生产饮用水的原地表水 水样采样 SOP-500/odběr A (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN EN ISO 5667-16; ČSN ISO 5667-5; ČSN EN ISO 5667-14; ČSN EN ISO 19458; Vyhláška č. 252/2004 Sb.)","categories":["water"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":79,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"}],"has_pdf":true}