🇨🇿 BETOTECH, s.r.o. PL
Construction
BETOTECH, s.r.o. is a laboratory accredited by ČIA under number 1195 (Beroun, Czech Republic). Its accreditation scope covers 79 test methods in the following areas: Construction. Test objects include: Hardened concrete, Fresh concrete, Aggregates, Fresh self-compacting concrete.
At a glance
- Accreditation number: ČIA 1195
- Methods in scope: 79
- Types of test objects: 8
- City: Beroun, Czech Republic
- Valid until: 11-09-2031
- Accreditation number
- 1195
- Accreditation body
- ČIA
- Address
- Beroun 660, 266 01 Beroun
- City
- Beroun, Czech Republic
- Division
- Laboratorium Badawcze Beroun
- Valid until
- 11-09-2031
What this laboratory tests (8)
- Hardened concrete — 26 methods
- Fresh concrete — 24 methods
- Aggregates — 16 methods
- Fresh self-compacting concrete — 6 methods
- Hydraulically bound mixture — 4 methods
- Cement — 1 method
- Mortar — 1 method
- Screed materials — 1 method
Laboratory sections (6)
- 2. Most — 21 methods
- 1. Beroun — 18 methods
- 4. Jindřichův Hradec — 12 methods
- 3. Trutnov — 11 methods
- 6. Cheb — 9 methods
- 5. Klatovy — 8 methods
Laboratory locations
- 1. Beroun — Areál cementárny, Beroun 660
- 2. Most — Areál MAPECO Most, a.s.
- 3. Trutnov — Kalná Voda 77
- 4. Jindřichův Hradec — Jarošovská 2217/II
- 5. Klatovy — Čertovka 890/2
- 6. Cheb — Karlovarská 40
Certificate information
- Certificate date
- 11.09.2026
Accreditation scope — test methods (79)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| 1. Beroun | |||||
| 1 | Aggregates | Determination of water content | ČSN EN 1097-5 | ||
| 2 | Aggregates | Determination of particle size distribution | ČSN EN 933-1 | ||
| 3 | Aggregates | Determination of particle density | ČSN EN 1097-6, mimo čl. 7, čl. A.3, příl. C, G | ||
| 4 | Aggregates | Determination of particle shape – shape index | ČSN EN 933-4 | ||
| 5 | Fresh self-compacting concrete | Determination of consistence by slump-flow | ČSN EN 12350-8 | ||
| 6 | Fresh concrete | Determination of density | ČSN EN 12350-6 | ||
| 7 | Fresh concrete | Determination of consistence – slump test | ČSN EN 12350-2 | ||
| 8 | Fresh concrete | Determination of consistence – flow table test | ČSN EN 12350-5 | ||
| 9 | Fresh concrete | Determination of air content – pressure gauge method | ČSN EN 12350-7 | ||
| 10 | Hardened concrete | Determination of density | ČSN EN 12390-7, mimo čl. 6.5 | ||
| 11 | Hardened concrete | Determination of compressive strength | ČSN EN 12390-3, mimo příl. A | ||
| 12 | Hardened concrete | Determination of flexural tensile strength | ČSN EN 12390-5 | ||
| 13 | Hardened concrete | Determination of frost resistance | ČSN 73 1322 | ||
| 14 | Hardened concrete | Determination of depth of penetration of water under pressure | ČSN EN 12390-8 | ||
| 15 | Hardened concrete | Determination of resistance of concrete surface to water and chemical de-icing agents | ČSN 73 1326, mimo čl. 24 až 29 | ||
| 16 | Screed materials | Determination of flexural and compressive strength | ČSN EN 13892-2 | ||
| 17 | Mortar | Determination of flexural and compressive strength | ČSN EN 1015-11 | ||
| 18 | Cement | Determination of flexural and compressive strength | ČSN EN 196-1 | ||
| 2. Most | |||||
| 19 | Aggregates | Determination of water content | ČSN EN 1097-5 | ||
| 20 | Aggregates | Determination of water absorption | ČSN EN 1097-6, mimo příl. C | ||
| 21 | Aggregates | Determination of particle size distribution | ČSN EN 933-1 | ||
| 22 | Aggregates | Determination of particle density | ČSN EN 1097-6, mimo čl. 7, čl. A.3, příl. C, G | ||
| 23 | Aggregates | Determination of particle shape – shape index | ČSN EN 933-4 | ||
| 24 | Fresh self-compacting concrete | Determination of consistence by slump-flow | ČSN EN 12350-8 | ||
| 25 | Fresh concrete | Determination of density | ČSN EN 12350-6 | ||
| 26 | Fresh concrete | Determination of consistence – slump test | ČSN EN 12350-2 | ||
| 27 | Fresh concrete | Determination of consistence – flow table test | ČSN EN 12350-5 | ||
| 28 | Fresh concrete | Determination of air content – pressure gauge method | ČSN EN 12350-7 | ||
| 29 | Hardened concrete | Determination of density | ČSN EN 12390-7, mimo čl. 6.5 | ||
| 30 | Hardened concrete | Determination of compressive strength | ČSN EN 12390-3, mimo příl. A | ||
| 31 | Hardened concrete | Determination of depth of penetration of water under pressure | ČSN EN 12390-8 | ||
| 32 | Hardened concrete | Determination of resistance of concrete surface to water and chemical de-icing agents | ČSN 73 1326, mimo čl. 24 až 29 | ||
| 33 | Hardened concrete | Determination of air void characteristics | ČSN EN 480-11 | ||
| 34 | Hardened concrete | Determination of static modulus of elasticity in compression | ČSN ISO 1920-10 | ||
| 35 | Aggregates | Determination of resistance to freezing and thawing | ČSN EN 1367-1 | ||
| 36 | Hydraulically bound mixture | Determination of the laboratory reference density | ČSN EN 13286-2, mimo čl. 7.3, 7.6 | ||
| 37 | Hydraulically bound mixture | Determination of compressive strength | ČSN EN 13286-41 | ||
| 38 | Hydraulically bound mixture | Determination of workability period | ČSN EN 13286-45, mimo čl. 6 | ||
| 39 | Hydraulically bound mixture | Determination of frost and water resistance of the mixture | ČSN 73 6124-1, příl. A | ||
| 3. Trutnov | |||||
| 40 | Aggregates | Determination of water content | ČSN EN 1097-5 | ||
| 41 | Aggregates | Determination of particle size distribution | ČSN EN 933-1 | ||
| 42 | Aggregates | Determination of particle shape – shape index | ČSN EN 933-4 | ||
| 43 | Fresh self-compacting concrete | Determination of consistence by slump-flow | ČSN EN 12350-8 | ||
| 44 | Fresh concrete | Determination of density | ČSN EN 12350-6 | ||
| 45 | Fresh concrete | Determination of consistence – slump test | ČSN EN 12350-2 | ||
| 46 | Fresh concrete | Determination of consistence – flow table test | ČSN EN 12350-5 | ||
| 47 | Fresh concrete | Determination of air content – pressure gauge method | ČSN EN 12350-7 | ||
| 48 | Hardened concrete | Determination of density | ČSN EN 12390-7, mimo čl. 6.5 | ||
| 49 | Hardened concrete | Determination of compressive strength | ČSN EN 12390-3, mimo příl. A | ||
| 50 | Hardened concrete | Determination of depth of penetration of water under pressure | ČSN EN 12390-8 | ||
| 4. Jindřichův Hradec | |||||
| 51 | Aggregates | Determination of water content | ČSN EN 1097-5 | ||
| 52 | Aggregates | Determination of particle size distribution | ČSN EN 933-1 | ||
| 53 | Aggregates | Determination of particle shape – shape index | ČSN EN 933-4 | ||
| 54 | Fresh self-compacting concrete | Determination of consistence by slump-flow | ČSN EN 12350-8 | ||
| 55 | Fresh concrete | Determination of density | ČSN EN 12350-6 | ||
| 56 | Fresh concrete | Determination of consistence – slump test | ČSN EN 12350-2 | ||
| 57 | Fresh concrete | Determination of consistence – flow table test | ČSN EN 12350-5 | ||
| 58 | Fresh concrete | Determination of air content – pressure gauge method | ČSN EN 12350-7 | ||
| 59 | Hardened concrete | Determination of density | ČSN EN 12390-7, mimo čl. 6.5 | ||
| 60 | Hardened concrete | Determination of compressive strength | ČSN EN 12390-3, mimo příl. A | ||
| 61 | Hardened concrete | Determination of depth of penetration of water under pressure | ČSN EN 12390-8 | ||
| 62 | Hardened concrete | Determination of resistance of concrete surface to water and chemical de-icing agents | ČSN 73 1326, mimo čl. 24 až 29 | ||
| 5. Klatovy | |||||
| 63 | Fresh self-compacting concrete | Determination of consistence by slump-flow | ČSN EN 12350-8 | ||
| 64 | Fresh concrete | Determination of density | ČSN EN 12350-6 | ||
| 65 | Fresh concrete | Determination of consistence – slump test | ČSN EN 12350-2 | ||
| 66 | Fresh concrete | Determination of consistence – flow table test | ČSN EN 12350-5 | ||
| 67 | Fresh concrete | Determination of air content – pressure gauge method | ČSN EN 12350-7 | ||
| 68 | Hardened concrete | Determination of density | ČSN EN 12390-7, mimo čl. 6.5 | ||
| 69 | Hardened concrete | Determination of compressive strength | ČSN EN 12390-3, mimo příl. A | ||
| 70 | Hardened concrete | Determination of depth of penetration of water under pressure | ČSN EN 12390-8 | ||
| 6. Cheb | |||||
| 71 | Fresh self-compacting concrete | Determination of consistence by slump-flow | ČSN EN 12350-8 | ||
| 72 | Fresh concrete | Determination of density | ČSN EN 12350-6 | ||
| 73 | Fresh concrete | Determination of consistence – slump test | ČSN EN 12350-2 | ||
| 74 | Fresh concrete | Determination of consistence – flow table test | ČSN EN 12350-5 | ||
| 75 | Fresh concrete | Determination of air content – pressure gauge method | ČSN EN 12350-7 | ||
| 76 | Hardened concrete | Determination of density | ČSN EN 12390-7, mimo čl. 6.5 | ||
| 77 | Hardened concrete | Determination of compressive strength | ČSN EN 12390-3, mimo příl. A | ||
| 78 | Hardened concrete | Determination of depth of penetration of water under pressure | ČSN EN 12390-8 | ||
| 79 | Hardened concrete | Determination of hardness and strength with non-guaranteed accuracy using a rebound hammer | ČSN EN 12504-2; ČSN 73 1373, čl. 6.2 | ||
Reference standards (28)
ČSN 73 1322
ČSN 73 1326, mimo čl. 24 až 29
ČSN 73 1373, čl. 6.2
ČSN 73 6124-1, příl. A
ČSN EN 1015-11
ČSN EN 1097-5
ČSN EN 1097-6, mimo příl. C
ČSN EN 1097-6, mimo čl. 7, čl. A.3, příl. C, G
ČSN EN 12350-2
ČSN EN 12350-5
ČSN EN 12350-6
ČSN EN 12350-7
ČSN EN 12350-8
ČSN EN 12390-3, mimo příl. A
ČSN EN 12390-5
ČSN EN 12390-7, mimo čl. 6.5
ČSN EN 12390-8
ČSN EN 12504-2
ČSN EN 13286-2, mimo čl. 7.3, 7.6
ČSN EN 13286-41
ČSN EN 13286-45, mimo čl. 6
ČSN EN 1367-1
ČSN EN 13892-2
ČSN EN 196-1
ČSN EN 480-11
ČSN EN 933-1
ČSN EN 933-4
ČSN ISO 1920-10