{"lab":{"_id":"69ad52a4de79e566650fd2da","accr_number":"1195","country":"CZ","accr_body":"ČIA","address":"Beroun 660, 266 01 Beroun","categories":["construction"],"city":"Beroun","imported_at":"2026-03-08T10:42:44.590Z","methods_count":79,"name":"BETOTECH, s.r.o.","parse_status":"parsed","parse_version":5,"pdf_files":["1195_371_2023_CS.pdf","1195_371_2023_EN.pdf"],"scope_summary":"Badania betonów świeżych i stwardniałych, fibrobetonów, kruszyw, cementów, materiałów jastrychowych, zapraw i mieszanek związanych spoiwem hydraulicznym, w zakresie określonym w załączniku do świadectwa.","search_text":"betotech, s.r.o. beroun 660, 266 01 beroun 1195","status":"active","updated_at":"2026-03-08T14:52:08.960Z","valid_from":"","valid_until":"11-09-2031","website":"www.betotech.cz","email_confidence":"high","email_mx":true,"email_source":"https://www.betotech.cz","map_coord":[49.949961,14.054139],"map_geo":"nominatim-street","certificate_date":"11.09.2026","certificate_no":"430/2026","certificate_replaces":"371/2023 z 13.07.2023","en_official":false,"fields_of_testing":[{"codes":"","pl":"Badania betonów świeżych i stwardniałych, fibrobetonów, kruszyw, cementów, materiałów jastrychowych, zapraw i mieszanek związanych spoiwem hydraulicznym, w zakresie określonym w załączniku do świadectwa.","en":"Testing of fresh and hardened concrete, fibre-reinforced concrete, aggregates, cements, screed materials, mortars and hydraulically bound mixtures, to the extent specified in the appendix to this Certificate.","zh":"新拌和硬化混凝土、纤维混凝土、集料、水泥、找平层材料、砂浆及水硬性结合料稳定混合料检测，范围见本证书附件。","cs":"Zkoušky čerstvých a ztvrdlých betonů, vláknobetonů, kameniva, cementů, potěrových materiálů, malt a směsí stmelených hydraulickým pojivem, vymezené přílohou tohoto osvědčení."}],"flexible_scope":false,"flexible_scope_url":null,"has_en":true,"has_zh":true,"lab_division":"Laboratorium Badawcze Beroun","lab_division_cs":"Zkušební laboratoř Beroun","lab_division_en":"Beroun Testing Laboratory","lab_division_zh":"贝龙检测实验室","lab_locations":[{"code":null,"name":"BETOTECH, s.r.o.","street":"Beroun 660","postal_code":"266 01","city":"Beroun","is_hq":true,"address":"Beroun 660, 266 01 Beroun","site":"26601|beroun660"},{"code":null,"name":"1. Beroun","street":"Areál cementárny, Beroun 660","postal_code":"266 01","city":"Beroun","is_hq":false,"address":"Areál cementárny, Beroun 660, 266 01 Beroun","site":"26601|areálcementárnyberoun660"},{"code":null,"name":"2. Most","street":"Areál MAPECO Most, a.s.","postal_code":"434 01","city":"Most – Čepirohy","is_hq":false,"address":"Areál MAPECO Most, a.s., 434 01 Most – Čepirohy","site":"43401|areálmapecomostas"},{"code":null,"name":"3. Trutnov","street":"Kalná Voda 77","postal_code":"542 23","city":"Mladé Buky","is_hq":false,"address":"Kalná Voda 77, 542 23 Mladé Buky","site":"54223|kalnávoda77"},{"code":null,"name":"4. Jindřichův Hradec","street":"Jarošovská 2217/II","postal_code":"377 01","city":"Jindřichův Hradec","is_hq":false,"address":"Jarošovská 2217/II, 377 01 Jindřichův Hradec","site":"37701|jarošovská2217/ii"},{"code":null,"name":"5. Klatovy","street":"Čertovka 890/2","postal_code":"339 01","city":"Klatovy","is_hq":false,"address":"Čertovka 890/2, 339 01 Klatovy","site":"33901|čertovka890/2"},{"code":null,"name":"6. Cheb","street":"Karlovarská 40","postal_code":"350 02","city":"Cheb","is_hq":false,"address":"Karlovarská 40, 350 02 Cheb","site":"35002|karlovarská40"}],"lab_locations_en":[{"code":null,"name":"BETOTECH, s.r.o.","street":"Beroun 660","postal_code":"266 01","city":"Beroun","is_hq":true,"address":"Beroun 660, 266 01 Beroun","site":"26601|beroun660"},{"code":null,"name":"1. Beroun","street":"Areál cementárny, Beroun 660","postal_code":"266 01","city":"Beroun","is_hq":false,"address":"Areál cementárny, Beroun 660, 266 01 Beroun","site":"26601|areálcementárnyberoun660"},{"code":null,"name":"2. Most","street":"Areál MAPECO Most, a.s.","postal_code":"434 01","city":"Most – Čepirohy","is_hq":false,"address":"Areál MAPECO Most, a.s., 434 01 Most – Čepirohy","site":"43401|areálmapecomostas"},{"code":null,"name":"3. Trutnov","street":"Kalná Voda 77","postal_code":"542 23","city":"Mladé Buky","is_hq":false,"address":"Kalná Voda 77, 542 23 Mladé Buky","site":"54223|kalnávoda77"},{"code":null,"name":"4. Jindřichův Hradec","street":"Jarošovská 2217/II","postal_code":"377 01","city":"Jindřichův Hradec","is_hq":false,"address":"Jarošovská 2217/II, 377 01 Jindřichův Hradec","site":"37701|jarošovská2217/ii"},{"code":null,"name":"5. Klatovy","street":"Čertovka 890/2","postal_code":"339 01","city":"Klatovy","is_hq":false,"address":"Čertovka 890/2, 339 01 Klatovy","site":"33901|čertovka890/2"},{"code":null,"name":"6. Cheb","street":"Karlovarská 40","postal_code":"350 02","city":"Cheb","is_hq":false,"address":"Karlovarská 40, 350 02 Cheb","site":"35002|karlovarská40"}],"lab_locations_zh":[{"code":null,"name":"BETOTECH, s.r.o.","street":"Beroun 660","postal_code":"266 01","city":"Beroun","is_hq":true,"address":"Beroun 660, 266 01 Beroun","site":"26601|beroun660"},{"code":null,"name":"1. 贝龙","street":"Areál cementárny, Beroun 660","postal_code":"266 01","city":"Beroun","is_hq":false,"address":"Areál cementárny, Beroun 660, 266 01 Beroun","site":"26601|areálcementárnyberoun660"},{"code":null,"name":"2. 莫斯特","street":"Areál MAPECO Most, a.s.","postal_code":"434 01","city":"Most – Čepirohy","is_hq":false,"address":"Areál MAPECO Most, a.s., 434 01 Most – Čepirohy","site":"43401|areálmapecomostas"},{"code":null,"name":"3. 特鲁特诺夫","street":"Kalná Voda 77","postal_code":"542 23","city":"Mladé Buky","is_hq":false,"address":"Kalná Voda 77, 542 23 Mladé Buky","site":"54223|kalnávoda77"},{"code":null,"name":"4. 因德日赫城","street":"Jarošovská 2217/II","postal_code":"377 01","city":"Jindřichův Hradec","is_hq":false,"address":"Jarošovská 2217/II, 377 01 Jindřichův Hradec","site":"37701|jarošovská2217/ii"},{"code":null,"name":"5. 克拉托维","street":"Čertovka 890/2","postal_code":"339 01","city":"Klatovy","is_hq":false,"address":"Čertovka 890/2, 339 01 Klatovy","site":"33901|čertovka890/2"},{"code":null,"name":"6. 海布","street":"Karlovarská 40","postal_code":"350 02","city":"Cheb","is_hq":false,"address":"Karlovarská 40, 350 02 Cheb","site":"35002|karlovarská40"}],"parse_date":"2026-09-28T12:00:00.000Z","parse_source":"reczna-analiza-labcoda-3","parsed_at":"2026-09-28T12:00:00.000Z","scope_legend":[],"scope_notes":[],"source_lang":"cs","source_pdf_sha256":"2d46c1835b15f2487d111868eeb2256fc7f378610dd7cdec648985d22bfa8c82","source_pdf_url":"https://www.cai.cz/OA/pdf/430_2026_CS.pdf","source_pdf_url_en":null},"methods":[{"_id":"8d2a2a32044c6a997f68ffcb","lab_id":"69ad52a4de79e566650fd2da","country":"CZ","accr_number":"1195","accr_body":"ČIA","row_label":"1","test_object":"Kruszywo","test_object_en":"Aggregates","test_object_zh":"集料","test_object_cs":"Kamenivo","methodology":"Oznaczanie wilgotności","methodology_en":"Determination of water content","methodology_zh":"含水率测定","methodology_cs":"Stanovení vlhkosti","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie wilgotności","reference":"ČSN EN 1097-5","norm_bases":["ČSN EN 1097-5"],"lab_section":"1. Beroun","lab_section_en":"1. Beroun","lab_section_zh":"1. 贝龙","lab_section_cs":"1. Beroun","lab_address":"Areál cementárny, Beroun 660, 266 01 Beroun","regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Kruszywo Oznaczanie wilgotności Kamenivo Stanovení vlhkosti ČSN EN 1097-5 Kruszywo Oznaczanie wilgotnosci Kamenivo Stanoveni vlhkosti CSN EN 1097-5","search_en":"Aggregates Determination of water content ČSN EN 1097-5","search_zh":"集料 含水率测定 ČSN EN 1097-5","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":0,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"6b2e787db09104691de13bf5","lab_id":"69ad52a4de79e566650fd2da","country":"CZ","accr_number":"1195","accr_body":"ČIA","row_label":"1","test_object":"Kruszywo","test_object_en":"Aggregates","test_object_zh":"集料","test_object_cs":"Kamenivo","methodology":"Oznaczanie wilgotności","methodology_en":"Determination of water content","methodology_zh":"含水率测定","methodology_cs":"Stanovení vlhkosti","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie wilgotności","reference":"ČSN EN 1097-5","norm_bases":["ČSN EN 1097-5"],"lab_section":"2. Most","lab_section_en":"2. Most","lab_section_zh":"2. 莫斯特","lab_section_cs":"2. Most","lab_address":"Areál MAPECO Most, a.s., 434 01 Most – Čepirohy","regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Kruszywo Oznaczanie wilgotności Kamenivo Stanovení vlhkosti ČSN EN 1097-5 Kruszywo Oznaczanie wilgotnosci Kamenivo Stanoveni vlhkosti CSN EN 1097-5","search_en":"Aggregates Determination of water content ČSN EN 1097-5","search_zh":"集料 含水率测定 ČSN EN 1097-5","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":1,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"25f5645079f8bf8a54aabee6","lab_id":"69ad52a4de79e566650fd2da","country":"CZ","accr_number":"1195","accr_body":"ČIA","row_label":"1","test_object":"Kruszywo","test_object_en":"Aggregates","test_object_zh":"集料","test_object_cs":"Kamenivo","methodology":"Oznaczanie wilgotności","methodology_en":"Determination of water content","methodology_zh":"含水率测定","methodology_cs":"Stanovení vlhkosti","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie wilgotności","reference":"ČSN EN 1097-5","norm_bases":["ČSN EN 1097-5"],"lab_section":"3. Trutnov","lab_section_en":"3. Trutnov","lab_section_zh":"3. 特鲁特诺夫","lab_section_cs":"3. Trutnov","lab_address":"Kalná Voda 77, 542 23 Mladé Buky","regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Kruszywo Oznaczanie wilgotności Kamenivo Stanovení vlhkosti ČSN EN 1097-5 Kruszywo Oznaczanie wilgotnosci Kamenivo Stanoveni vlhkosti CSN EN 1097-5","search_en":"Aggregates Determination of water content ČSN EN 1097-5","search_zh":"集料 含水率测定 ČSN EN 1097-5","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":2,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"0c8706ed99dc38148b6db6f8","lab_id":"69ad52a4de79e566650fd2da","country":"CZ","accr_number":"1195","accr_body":"ČIA","row_label":"1","test_object":"Kruszywo","test_object_en":"Aggregates","test_object_zh":"集料","test_object_cs":"Kamenivo","methodology":"Oznaczanie wilgotności","methodology_en":"Determination of water content","methodology_zh":"含水率测定","methodology_cs":"Stanovení vlhkosti","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie wilgotności","reference":"ČSN EN 1097-5","norm_bases":["ČSN EN 1097-5"],"lab_section":"4. Jindřichův Hradec","lab_section_en":"4. Jindřichův Hradec","lab_section_zh":"4. 因德日赫城","lab_section_cs":"4. Jindřichův Hradec","lab_address":"Jarošovská 2217/II, 377 01 Jindřichův Hradec","regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Kruszywo Oznaczanie wilgotności Kamenivo Stanovení vlhkosti ČSN EN 1097-5 Kruszywo Oznaczanie wilgotnosci Kamenivo Stanoveni vlhkosti CSN EN 1097-5","search_en":"Aggregates Determination of water content ČSN EN 1097-5","search_zh":"集料 含水率测定 ČSN EN 1097-5","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":3,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"8ff3f92786c3a274d1f2b2c8","lab_id":"69ad52a4de79e566650fd2da","country":"CZ","accr_number":"1195","accr_body":"ČIA","row_label":"2","test_object":"Kruszywo","test_object_en":"Aggregates","test_object_zh":"集料","test_object_cs":"Kamenivo","methodology":"Oznaczanie nasiąkliwości","methodology_en":"Determination of water absorption","methodology_zh":"吸水率测定","methodology_cs":"Stanovení nasákavosti","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie nasiąkliwości","reference":"ČSN EN 1097-6, mimo příl. C","norm_bases":["ČSN EN 1097-6, mimo příl. C"],"lab_section":"2. Most","lab_section_en":"2. Most","lab_section_zh":"2. 莫斯特","lab_section_cs":"2. Most","lab_address":"Areál MAPECO Most, a.s., 434 01 Most – Čepirohy","regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Kruszywo Oznaczanie nasiąkliwości Kamenivo Stanovení nasákavosti ČSN EN 1097-6, mimo příl. C Kruszywo Oznaczanie nasiakliwosci Kamenivo Stanoveni nasakavosti CSN EN 1097-6, mimo pril. C","search_en":"Aggregates Determination of water absorption ČSN EN 1097-6, mimo příl. C","search_zh":"集料 吸水率测定 ČSN EN 1097-6, mimo příl. C","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":4,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"f45b7fd3199264609dd9092f","lab_id":"69ad52a4de79e566650fd2da","country":"CZ","accr_number":"1195","accr_body":"ČIA","row_label":"3","test_object":"Kruszywo","test_object_en":"Aggregates","test_object_zh":"集料","test_object_cs":"Kamenivo","methodology":"Oznaczanie uziarnienia","methodology_en":"Determination of particle size distribution","methodology_zh":"粒径分布测定","methodology_cs":"Stanovení zrnitosti","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie uziarnienia","reference":"ČSN EN 933-1","norm_bases":["ČSN EN 933-1"],"lab_section":"1. Beroun","lab_section_en":"1. Beroun","lab_section_zh":"1. 贝龙","lab_section_cs":"1. Beroun","lab_address":"Areál cementárny, Beroun 660, 266 01 Beroun","regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Kruszywo Oznaczanie uziarnienia Kamenivo Stanovení zrnitosti ČSN EN 933-1 Kruszywo Oznaczanie uziarnienia Kamenivo Stanoveni zrnitosti CSN EN 933-1","search_en":"Aggregates Determination of particle size distribution ČSN EN 933-1","search_zh":"集料 粒径分布测定 ČSN EN 933-1","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":5,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"d95e2c9a9e15498e53602436","lab_id":"69ad52a4de79e566650fd2da","country":"CZ","accr_number":"1195","accr_body":"ČIA","row_label":"3","test_object":"Kruszywo","test_object_en":"Aggregates","test_object_zh":"集料","test_object_cs":"Kamenivo","methodology":"Oznaczanie uziarnienia","methodology_en":"Determination of particle size distribution","methodology_zh":"粒径分布测定","methodology_cs":"Stanovení zrnitosti","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie uziarnienia","reference":"ČSN EN 933-1","norm_bases":["ČSN EN 933-1"],"lab_section":"2. Most","lab_section_en":"2. Most","lab_section_zh":"2. 莫斯特","lab_section_cs":"2. Most","lab_address":"Areál MAPECO Most, a.s., 434 01 Most – Čepirohy","regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Kruszywo Oznaczanie uziarnienia Kamenivo Stanovení zrnitosti ČSN EN 933-1 Kruszywo Oznaczanie uziarnienia Kamenivo Stanoveni zrnitosti CSN EN 933-1","search_en":"Aggregates Determination of particle size distribution ČSN EN 933-1","search_zh":"集料 粒径分布测定 ČSN EN 933-1","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":6,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"2986e3407be143b8332dffee","lab_id":"69ad52a4de79e566650fd2da","country":"CZ","accr_number":"1195","accr_body":"ČIA","row_label":"3","test_object":"Kruszywo","test_object_en":"Aggregates","test_object_zh":"集料","test_object_cs":"Kamenivo","methodology":"Oznaczanie uziarnienia","methodology_en":"Determination of particle size distribution","methodology_zh":"粒径分布测定","methodology_cs":"Stanovení zrnitosti","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie uziarnienia","reference":"ČSN EN 933-1","norm_bases":["ČSN EN 933-1"],"lab_section":"3. Trutnov","lab_section_en":"3. Trutnov","lab_section_zh":"3. 特鲁特诺夫","lab_section_cs":"3. Trutnov","lab_address":"Kalná Voda 77, 542 23 Mladé Buky","regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Kruszywo Oznaczanie uziarnienia Kamenivo Stanovení zrnitosti ČSN EN 933-1 Kruszywo Oznaczanie uziarnienia Kamenivo Stanoveni zrnitosti CSN EN 933-1","search_en":"Aggregates Determination of particle size distribution ČSN EN 933-1","search_zh":"集料 粒径分布测定 ČSN EN 933-1","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":7,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"25cfea5d3bf2df62e31eb4d6","lab_id":"69ad52a4de79e566650fd2da","country":"CZ","accr_number":"1195","accr_body":"ČIA","row_label":"3","test_object":"Kruszywo","test_object_en":"Aggregates","test_object_zh":"集料","test_object_cs":"Kamenivo","methodology":"Oznaczanie uziarnienia","methodology_en":"Determination of particle size distribution","methodology_zh":"粒径分布测定","methodology_cs":"Stanovení zrnitosti","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie uziarnienia","reference":"ČSN EN 933-1","norm_bases":["ČSN EN 933-1"],"lab_section":"4. Jindřichův Hradec","lab_section_en":"4. Jindřichův Hradec","lab_section_zh":"4. 因德日赫城","lab_section_cs":"4. Jindřichův Hradec","lab_address":"Jarošovská 2217/II, 377 01 Jindřichův Hradec","regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Kruszywo Oznaczanie uziarnienia Kamenivo Stanovení zrnitosti ČSN EN 933-1 Kruszywo Oznaczanie uziarnienia Kamenivo Stanoveni zrnitosti CSN EN 933-1","search_en":"Aggregates Determination of particle size distribution ČSN EN 933-1","search_zh":"集料 粒径分布测定 ČSN EN 933-1","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":8,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"58565f19f0781a581bf9120e","lab_id":"69ad52a4de79e566650fd2da","country":"CZ","accr_number":"1195","accr_body":"ČIA","row_label":"4","test_object":"Kruszywo","test_object_en":"Aggregates","test_object_zh":"集料","test_object_cs":"Kamenivo","methodology":"Oznaczanie gęstości objętościowej","methodology_en":"Determination of particle density","methodology_zh":"颗粒密度测定","methodology_cs":"Stanovení objemové hmotnosti","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie gęstości objętościowej","reference":"ČSN EN 1097-6, mimo čl. 7, čl. A.3, příl. C, G","norm_bases":["ČSN EN 1097-6, mimo čl. 7, čl. A.3, příl. C, G"],"lab_section":"1. Beroun","lab_section_en":"1. Beroun","lab_section_zh":"1. 贝龙","lab_section_cs":"1. Beroun","lab_address":"Areál cementárny, Beroun 660, 266 01 Beroun","regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Kruszywo Oznaczanie gęstości objętościowej Kamenivo Stanovení objemové hmotnosti ČSN EN 1097-6, mimo čl. 7, čl. A.3, příl. C, G Kruszywo Oznaczanie gestosci objetosciowej Kamenivo Stanoveni objemove hmotnosti CSN EN 1097-6, mimo cl. 7, cl. A.3, pril. C, G","search_en":"Aggregates Determination of particle density ČSN EN 1097-6, mimo čl. 7, čl. A.3, příl. C, G","search_zh":"集料 颗粒密度测定 ČSN EN 1097-6, mimo čl. 7, čl. A.3, příl. C, G","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":9,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"7c94507c0f469421f39b027b","lab_id":"69ad52a4de79e566650fd2da","country":"CZ","accr_number":"1195","accr_body":"ČIA","row_label":"4","test_object":"Kruszywo","test_object_en":"Aggregates","test_object_zh":"集料","test_object_cs":"Kamenivo","methodology":"Oznaczanie gęstości objętościowej","methodology_en":"Determination of particle density","methodology_zh":"颗粒密度测定","methodology_cs":"Stanovení objemové hmotnosti","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie gęstości objętościowej","reference":"ČSN EN 1097-6, mimo čl. 7, čl. A.3, příl. C, G","norm_bases":["ČSN EN 1097-6, mimo čl. 7, čl. A.3, příl. C, G"],"lab_section":"2. Most","lab_section_en":"2. Most","lab_section_zh":"2. 莫斯特","lab_section_cs":"2. Most","lab_address":"Areál MAPECO Most, a.s., 434 01 Most – Čepirohy","regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Kruszywo Oznaczanie gęstości objętościowej Kamenivo Stanovení objemové hmotnosti ČSN EN 1097-6, mimo čl. 7, čl. A.3, příl. C, G Kruszywo Oznaczanie gestosci objetosciowej Kamenivo Stanoveni objemove hmotnosti CSN EN 1097-6, mimo cl. 7, cl. A.3, pril. C, G","search_en":"Aggregates Determination of particle density ČSN EN 1097-6, mimo čl. 7, čl. A.3, příl. C, G","search_zh":"集料 颗粒密度测定 ČSN EN 1097-6, mimo čl. 7, čl. A.3, příl. C, G","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":10,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"ffb03f579fc6888eef2fd76a","lab_id":"69ad52a4de79e566650fd2da","country":"CZ","accr_number":"1195","accr_body":"ČIA","row_label":"5","test_object":"Kruszywo","test_object_en":"Aggregates","test_object_zh":"集料","test_object_cs":"Kamenivo","methodology":"Oznaczanie kształtu ziaren – wskaźnik kształtu","methodology_en":"Determination of particle shape – shape index","methodology_zh":"颗粒形状测定——形状指数","methodology_cs":"Stanovení tvaru zrn – tvarový index","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie kształtu ziaren – wskaźnik kształtu","reference":"ČSN EN 933-4","norm_bases":["ČSN EN 933-4"],"lab_section":"1. Beroun","lab_section_en":"1. Beroun","lab_section_zh":"1. 贝龙","lab_section_cs":"1. Beroun","lab_address":"Areál cementárny, Beroun 660, 266 01 Beroun","regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Kruszywo Oznaczanie kształtu ziaren – wskaźnik kształtu Kamenivo Stanovení tvaru zrn – tvarový index ČSN EN 933-4 Kruszywo Oznaczanie ksztaltu ziaren – wskaznik ksztaltu Kamenivo Stanoveni tvaru zrn – tvarovy index CSN EN 933-4","search_en":"Aggregates Determination of particle shape – shape index ČSN EN 933-4","search_zh":"集料 颗粒形状测定——形状指数 ČSN EN 933-4","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":11,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"e8a7f82014dbf11aa5291d99","lab_id":"69ad52a4de79e566650fd2da","country":"CZ","accr_number":"1195","accr_body":"ČIA","row_label":"5","test_object":"Kruszywo","test_object_en":"Aggregates","test_object_zh":"集料","test_object_cs":"Kamenivo","methodology":"Oznaczanie kształtu ziaren – wskaźnik kształtu","methodology_en":"Determination of particle shape – shape index","methodology_zh":"颗粒形状测定——形状指数","methodology_cs":"Stanovení tvaru zrn – tvarový index","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie kształtu ziaren – wskaźnik kształtu","reference":"ČSN EN 933-4","norm_bases":["ČSN EN 933-4"],"lab_section":"2. Most","lab_section_en":"2. Most","lab_section_zh":"2. 莫斯特","lab_section_cs":"2. Most","lab_address":"Areál MAPECO Most, a.s., 434 01 Most – Čepirohy","regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Kruszywo Oznaczanie kształtu ziaren – wskaźnik kształtu Kamenivo Stanovení tvaru zrn – tvarový index ČSN EN 933-4 Kruszywo Oznaczanie ksztaltu ziaren – wskaznik ksztaltu Kamenivo Stanoveni tvaru zrn – tvarovy index CSN EN 933-4","search_en":"Aggregates Determination of particle shape – shape index ČSN EN 933-4","search_zh":"集料 颗粒形状测定——形状指数 ČSN EN 933-4","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":12,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"5483ca3bd236f8e8ecc615eb","lab_id":"69ad52a4de79e566650fd2da","country":"CZ","accr_number":"1195","accr_body":"ČIA","row_label":"5","test_object":"Kruszywo","test_object_en":"Aggregates","test_object_zh":"集料","test_object_cs":"Kamenivo","methodology":"Oznaczanie kształtu ziaren – wskaźnik kształtu","methodology_en":"Determination of particle shape – shape index","methodology_zh":"颗粒形状测定——形状指数","methodology_cs":"Stanovení tvaru zrn – tvarový index","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie kształtu ziaren – wskaźnik kształtu","reference":"ČSN EN 933-4","norm_bases":["ČSN EN 933-4"],"lab_section":"3. Trutnov","lab_section_en":"3. Trutnov","lab_section_zh":"3. 特鲁特诺夫","lab_section_cs":"3. Trutnov","lab_address":"Kalná Voda 77, 542 23 Mladé Buky","regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Kruszywo Oznaczanie kształtu ziaren – wskaźnik kształtu Kamenivo Stanovení tvaru zrn – tvarový index ČSN EN 933-4 Kruszywo Oznaczanie ksztaltu ziaren – wskaznik ksztaltu Kamenivo Stanoveni tvaru zrn – tvarovy index CSN EN 933-4","search_en":"Aggregates Determination of particle shape – shape index ČSN EN 933-4","search_zh":"集料 颗粒形状测定——形状指数 ČSN EN 933-4","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":13,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"be0da35c886b3d0442e001c2","lab_id":"69ad52a4de79e566650fd2da","country":"CZ","accr_number":"1195","accr_body":"ČIA","row_label":"5","test_object":"Kruszywo","test_object_en":"Aggregates","test_object_zh":"集料","test_object_cs":"Kamenivo","methodology":"Oznaczanie kształtu ziaren – wskaźnik kształtu","methodology_en":"Determination of particle shape – shape index","methodology_zh":"颗粒形状测定——形状指数","methodology_cs":"Stanovení tvaru zrn – tvarový index","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie kształtu ziaren – wskaźnik kształtu","reference":"ČSN EN 933-4","norm_bases":["ČSN EN 933-4"],"lab_section":"4. Jindřichův Hradec","lab_section_en":"4. Jindřichův Hradec","lab_section_zh":"4. 因德日赫城","lab_section_cs":"4. Jindřichův Hradec","lab_address":"Jarošovská 2217/II, 377 01 Jindřichův Hradec","regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Kruszywo Oznaczanie kształtu ziaren – wskaźnik kształtu Kamenivo Stanovení tvaru zrn – tvarový index ČSN EN 933-4 Kruszywo Oznaczanie ksztaltu ziaren – wskaznik ksztaltu Kamenivo Stanoveni tvaru zrn – tvarovy index CSN EN 933-4","search_en":"Aggregates Determination of particle shape – shape index ČSN EN 933-4","search_zh":"集料 颗粒形状测定——形状指数 ČSN EN 933-4","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":14,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"566f55c0c418b767bec7b0a8","lab_id":"69ad52a4de79e566650fd2da","country":"CZ","accr_number":"1195","accr_body":"ČIA","row_label":"6","test_object":"Świeży beton samozagęszczalny","test_object_en":"Fresh self-compacting concrete","test_object_zh":"新拌自密实混凝土","test_object_cs":"Čerstvý samozhutnitelný beton","methodology":"Oznaczanie konsystencji metodą rozpływu stożka (slump-flow)","methodology_en":"Determination of consistence by slump-flow","methodology_zh":"坍落扩展度法测定稠度","methodology_cs":"Stanovení konzistence sednutím – rozlitím","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie konsystencji metodą rozpływu stożka (slump-flow)","reference":"ČSN EN 12350-8","norm_bases":["ČSN EN 12350-8"],"lab_section":"1. Beroun","lab_section_en":"1. Beroun","lab_section_zh":"1. 贝龙","lab_section_cs":"1. Beroun","lab_address":"Areál cementárny, Beroun 660, 266 01 Beroun","regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Świeży beton samozagęszczalny Oznaczanie konsystencji metodą rozpływu stożka (slump-flow) Čerstvý samozhutnitelný beton Stanovení konzistence sednutím – rozlitím ČSN EN 12350-8 Swiezy beton samozageszczalny Oznaczanie konsystencji metoda rozplywu stozka (slump-flow) Cerstvy samozhutnitelny beton Stanoveni konzistence sednutim – rozlitim CSN EN 12350-8","search_en":"Fresh self-compacting concrete Determination of consistence by slump-flow ČSN EN 12350-8","search_zh":"新拌自密实混凝土 坍落扩展度法测定稠度 ČSN EN 12350-8","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":15,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"1386f27f943f3586d1d84478","lab_id":"69ad52a4de79e566650fd2da","country":"CZ","accr_number":"1195","accr_body":"ČIA","row_label":"6","test_object":"Świeży beton samozagęszczalny","test_object_en":"Fresh self-compacting concrete","test_object_zh":"新拌自密实混凝土","test_object_cs":"Čerstvý samozhutnitelný beton","methodology":"Oznaczanie konsystencji metodą rozpływu stożka (slump-flow)","methodology_en":"Determination of consistence by slump-flow","methodology_zh":"坍落扩展度法测定稠度","methodology_cs":"Stanovení konzistence sednutím – rozlitím","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie konsystencji metodą rozpływu stożka (slump-flow)","reference":"ČSN EN 12350-8","norm_bases":["ČSN EN 12350-8"],"lab_section":"2. Most","lab_section_en":"2. Most","lab_section_zh":"2. 莫斯特","lab_section_cs":"2. Most","lab_address":"Areál MAPECO Most, a.s., 434 01 Most – Čepirohy","regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Świeży beton samozagęszczalny Oznaczanie konsystencji metodą rozpływu stożka (slump-flow) Čerstvý samozhutnitelný beton Stanovení konzistence sednutím – rozlitím ČSN EN 12350-8 Swiezy beton samozageszczalny Oznaczanie konsystencji metoda rozplywu stozka (slump-flow) Cerstvy samozhutnitelny beton Stanoveni konzistence sednutim – rozlitim CSN EN 12350-8","search_en":"Fresh self-compacting concrete Determination of consistence by slump-flow ČSN EN 12350-8","search_zh":"新拌自密实混凝土 坍落扩展度法测定稠度 ČSN EN 12350-8","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":16,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"f308bda75643cfafc3aa7cac","lab_id":"69ad52a4de79e566650fd2da","country":"CZ","accr_number":"1195","accr_body":"ČIA","row_label":"6","test_object":"Świeży beton samozagęszczalny","test_object_en":"Fresh self-compacting concrete","test_object_zh":"新拌自密实混凝土","test_object_cs":"Čerstvý samozhutnitelný beton","methodology":"Oznaczanie konsystencji metodą rozpływu stożka (slump-flow)","methodology_en":"Determination of consistence by slump-flow","methodology_zh":"坍落扩展度法测定稠度","methodology_cs":"Stanovení konzistence sednutím – rozlitím","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie konsystencji metodą rozpływu stożka (slump-flow)","reference":"ČSN EN 12350-8","norm_bases":["ČSN EN 12350-8"],"lab_section":"3. Trutnov","lab_section_en":"3. Trutnov","lab_section_zh":"3. 特鲁特诺夫","lab_section_cs":"3. Trutnov","lab_address":"Kalná Voda 77, 542 23 Mladé Buky","regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Świeży beton samozagęszczalny Oznaczanie konsystencji metodą rozpływu stożka (slump-flow) Čerstvý samozhutnitelný beton Stanovení konzistence sednutím – rozlitím ČSN EN 12350-8 Swiezy beton samozageszczalny Oznaczanie konsystencji metoda rozplywu stozka (slump-flow) Cerstvy samozhutnitelny beton Stanoveni konzistence sednutim – rozlitim CSN EN 12350-8","search_en":"Fresh self-compacting concrete Determination of consistence by slump-flow ČSN EN 12350-8","search_zh":"新拌自密实混凝土 坍落扩展度法测定稠度 ČSN EN 12350-8","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":17,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"bfb1b8b2b8e95b063e6a3484","lab_id":"69ad52a4de79e566650fd2da","country":"CZ","accr_number":"1195","accr_body":"ČIA","row_label":"6","test_object":"Świeży beton samozagęszczalny","test_object_en":"Fresh self-compacting concrete","test_object_zh":"新拌自密实混凝土","test_object_cs":"Čerstvý samozhutnitelný beton","methodology":"Oznaczanie konsystencji metodą rozpływu stożka (slump-flow)","methodology_en":"Determination of consistence by slump-flow","methodology_zh":"坍落扩展度法测定稠度","methodology_cs":"Stanovení konzistence sednutím – rozlitím","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie konsystencji metodą rozpływu stożka (slump-flow)","reference":"ČSN EN 12350-8","norm_bases":["ČSN EN 12350-8"],"lab_section":"4. Jindřichův Hradec","lab_section_en":"4. Jindřichův Hradec","lab_section_zh":"4. 因德日赫城","lab_section_cs":"4. Jindřichův Hradec","lab_address":"Jarošovská 2217/II, 377 01 Jindřichův Hradec","regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Świeży beton samozagęszczalny Oznaczanie konsystencji metodą rozpływu stożka (slump-flow) Čerstvý samozhutnitelný beton Stanovení konzistence sednutím – rozlitím ČSN EN 12350-8 Swiezy beton samozageszczalny Oznaczanie konsystencji metoda rozplywu stozka (slump-flow) Cerstvy samozhutnitelny beton Stanoveni konzistence sednutim – rozlitim CSN EN 12350-8","search_en":"Fresh self-compacting concrete Determination of consistence by slump-flow ČSN EN 12350-8","search_zh":"新拌自密实混凝土 坍落扩展度法测定稠度 ČSN EN 12350-8","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":18,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"557d04889c6954cabb331668","lab_id":"69ad52a4de79e566650fd2da","country":"CZ","accr_number":"1195","accr_body":"ČIA","row_label":"6","test_object":"Świeży beton samozagęszczalny","test_object_en":"Fresh self-compacting concrete","test_object_zh":"新拌自密实混凝土","test_object_cs":"Čerstvý samozhutnitelný beton","methodology":"Oznaczanie konsystencji metodą rozpływu stożka (slump-flow)","methodology_en":"Determination of consistence by slump-flow","methodology_zh":"坍落扩展度法测定稠度","methodology_cs":"Stanovení konzistence sednutím – rozlitím","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie konsystencji metodą rozpływu stożka (slump-flow)","reference":"ČSN EN 12350-8","norm_bases":["ČSN EN 12350-8"],"lab_section":"5. Klatovy","lab_section_en":"5. Klatovy","lab_section_zh":"5. 克拉托维","lab_section_cs":"5. Klatovy","lab_address":"Čertovka 890/2, 339 01 Klatovy","regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Świeży beton samozagęszczalny Oznaczanie konsystencji metodą rozpływu stożka (slump-flow) Čerstvý samozhutnitelný beton Stanovení konzistence sednutím – rozlitím ČSN EN 12350-8 Swiezy beton samozageszczalny Oznaczanie konsystencji metoda rozplywu stozka (slump-flow) Cerstvy samozhutnitelny beton Stanoveni konzistence sednutim – rozlitim CSN EN 12350-8","search_en":"Fresh self-compacting concrete Determination of consistence by slump-flow ČSN EN 12350-8","search_zh":"新拌自密实混凝土 坍落扩展度法测定稠度 ČSN EN 12350-8","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":19,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"495d0882e7b2a25f88e3e18b","lab_id":"69ad52a4de79e566650fd2da","country":"CZ","accr_number":"1195","accr_body":"ČIA","row_label":"6","test_object":"Świeży beton samozagęszczalny","test_object_en":"Fresh self-compacting concrete","test_object_zh":"新拌自密实混凝土","test_object_cs":"Čerstvý samozhutnitelný beton","methodology":"Oznaczanie konsystencji metodą rozpływu stożka (slump-flow)","methodology_en":"Determination of consistence by slump-flow","methodology_zh":"坍落扩展度法测定稠度","methodology_cs":"Stanovení konzistence sednutím – rozlitím","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie konsystencji metodą rozpływu stożka (slump-flow)","reference":"ČSN EN 12350-8","norm_bases":["ČSN EN 12350-8"],"lab_section":"6. Cheb","lab_section_en":"6. Cheb","lab_section_zh":"6. 海布","lab_section_cs":"6. Cheb","lab_address":"Karlovarská 40, 350 02 Cheb","regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Świeży beton samozagęszczalny Oznaczanie konsystencji metodą rozpływu stożka (slump-flow) Čerstvý samozhutnitelný beton Stanovení konzistence sednutím – rozlitím ČSN EN 12350-8 Swiezy beton samozageszczalny Oznaczanie konsystencji metoda rozplywu stozka (slump-flow) Cerstvy samozhutnitelny beton Stanoveni konzistence sednutim – rozlitim CSN EN 12350-8","search_en":"Fresh self-compacting concrete Determination of consistence by slump-flow ČSN EN 12350-8","search_zh":"新拌自密实混凝土 坍落扩展度法测定稠度 ČSN EN 12350-8","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":20,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"1e077d208e2dd084eb933d56","lab_id":"69ad52a4de79e566650fd2da","country":"CZ","accr_number":"1195","accr_body":"ČIA","row_label":"7","test_object":"Beton świeży","test_object_en":"Fresh concrete","test_object_zh":"新拌混凝土","test_object_cs":"Čerstvý beton","methodology":"Oznaczanie gęstości","methodology_en":"Determination of density","methodology_zh":"密度测定","methodology_cs":"Stanovení objemové hmotnosti","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie gęstości","reference":"ČSN EN 12350-6","norm_bases":["ČSN EN 12350-6"],"lab_section":"1. Beroun","lab_section_en":"1. Beroun","lab_section_zh":"1. 贝龙","lab_section_cs":"1. Beroun","lab_address":"Areál cementárny, Beroun 660, 266 01 Beroun","regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Beton świeży Oznaczanie gęstości Čerstvý beton Stanovení objemové hmotnosti ČSN EN 12350-6 Beton swiezy Oznaczanie gestosci Cerstvy beton Stanoveni objemove hmotnosti CSN EN 12350-6","search_en":"Fresh concrete Determination of density ČSN EN 12350-6","search_zh":"新拌混凝土 密度测定 ČSN EN 12350-6","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":21,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"debca91e4d6d179c57b186a7","lab_id":"69ad52a4de79e566650fd2da","country":"CZ","accr_number":"1195","accr_body":"ČIA","row_label":"7","test_object":"Beton świeży","test_object_en":"Fresh concrete","test_object_zh":"新拌混凝土","test_object_cs":"Čerstvý beton","methodology":"Oznaczanie gęstości","methodology_en":"Determination of density","methodology_zh":"密度测定","methodology_cs":"Stanovení objemové hmotnosti","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie gęstości","reference":"ČSN EN 12350-6","norm_bases":["ČSN EN 12350-6"],"lab_section":"2. Most","lab_section_en":"2. Most","lab_section_zh":"2. 莫斯特","lab_section_cs":"2. Most","lab_address":"Areál MAPECO Most, a.s., 434 01 Most – Čepirohy","regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Beton świeży Oznaczanie gęstości Čerstvý beton Stanovení objemové hmotnosti ČSN EN 12350-6 Beton swiezy Oznaczanie gestosci Cerstvy beton Stanoveni objemove hmotnosti CSN EN 12350-6","search_en":"Fresh concrete Determination of density ČSN EN 12350-6","search_zh":"新拌混凝土 密度测定 ČSN EN 12350-6","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":22,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"cc487fe995bf213b8419fbfd","lab_id":"69ad52a4de79e566650fd2da","country":"CZ","accr_number":"1195","accr_body":"ČIA","row_label":"7","test_object":"Beton świeży","test_object_en":"Fresh concrete","test_object_zh":"新拌混凝土","test_object_cs":"Čerstvý beton","methodology":"Oznaczanie gęstości","methodology_en":"Determination of density","methodology_zh":"密度测定","methodology_cs":"Stanovení objemové hmotnosti","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie gęstości","reference":"ČSN EN 12350-6","norm_bases":["ČSN EN 12350-6"],"lab_section":"3. Trutnov","lab_section_en":"3. Trutnov","lab_section_zh":"3. 特鲁特诺夫","lab_section_cs":"3. Trutnov","lab_address":"Kalná Voda 77, 542 23 Mladé Buky","regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Beton świeży Oznaczanie gęstości Čerstvý beton Stanovení objemové hmotnosti ČSN EN 12350-6 Beton swiezy Oznaczanie gestosci Cerstvy beton Stanoveni objemove hmotnosti CSN EN 12350-6","search_en":"Fresh concrete Determination of density ČSN EN 12350-6","search_zh":"新拌混凝土 密度测定 ČSN EN 12350-6","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":23,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"c6ff019aaacb3748f3f932eb","lab_id":"69ad52a4de79e566650fd2da","country":"CZ","accr_number":"1195","accr_body":"ČIA","row_label":"7","test_object":"Beton świeży","test_object_en":"Fresh concrete","test_object_zh":"新拌混凝土","test_object_cs":"Čerstvý beton","methodology":"Oznaczanie gęstości","methodology_en":"Determination of density","methodology_zh":"密度测定","methodology_cs":"Stanovení objemové hmotnosti","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie gęstości","reference":"ČSN EN 12350-6","norm_bases":["ČSN EN 12350-6"],"lab_section":"4. Jindřichův Hradec","lab_section_en":"4. Jindřichův Hradec","lab_section_zh":"4. 因德日赫城","lab_section_cs":"4. Jindřichův Hradec","lab_address":"Jarošovská 2217/II, 377 01 Jindřichův Hradec","regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Beton świeży Oznaczanie gęstości Čerstvý beton Stanovení objemové hmotnosti ČSN EN 12350-6 Beton swiezy Oznaczanie gestosci Cerstvy beton Stanoveni objemove hmotnosti CSN EN 12350-6","search_en":"Fresh concrete Determination of density ČSN EN 12350-6","search_zh":"新拌混凝土 密度测定 ČSN EN 12350-6","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":24,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"249746cfa99ca455abeaa720","lab_id":"69ad52a4de79e566650fd2da","country":"CZ","accr_number":"1195","accr_body":"ČIA","row_label":"7","test_object":"Beton świeży","test_object_en":"Fresh concrete","test_object_zh":"新拌混凝土","test_object_cs":"Čerstvý beton","methodology":"Oznaczanie gęstości","methodology_en":"Determination of density","methodology_zh":"密度测定","methodology_cs":"Stanovení objemové hmotnosti","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie gęstości","reference":"ČSN EN 12350-6","norm_bases":["ČSN EN 12350-6"],"lab_section":"5. Klatovy","lab_section_en":"5. Klatovy","lab_section_zh":"5. 克拉托维","lab_section_cs":"5. Klatovy","lab_address":"Čertovka 890/2, 339 01 Klatovy","regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Beton świeży Oznaczanie gęstości Čerstvý beton Stanovení objemové hmotnosti ČSN EN 12350-6 Beton swiezy Oznaczanie gestosci Cerstvy beton Stanoveni objemove hmotnosti CSN EN 12350-6","search_en":"Fresh concrete Determination of density ČSN EN 12350-6","search_zh":"新拌混凝土 密度测定 ČSN EN 12350-6","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":25,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"1e0c55fcc2edfd22db426817","lab_id":"69ad52a4de79e566650fd2da","country":"CZ","accr_number":"1195","accr_body":"ČIA","row_label":"7","test_object":"Beton świeży","test_object_en":"Fresh concrete","test_object_zh":"新拌混凝土","test_object_cs":"Čerstvý beton","methodology":"Oznaczanie gęstości","methodology_en":"Determination of density","methodology_zh":"密度测定","methodology_cs":"Stanovení objemové hmotnosti","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie gęstości","reference":"ČSN EN 12350-6","norm_bases":["ČSN EN 12350-6"],"lab_section":"6. Cheb","lab_section_en":"6. Cheb","lab_section_zh":"6. 海布","lab_section_cs":"6. Cheb","lab_address":"Karlovarská 40, 350 02 Cheb","regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Beton świeży Oznaczanie gęstości Čerstvý beton Stanovení objemové hmotnosti ČSN EN 12350-6 Beton swiezy Oznaczanie gestosci Cerstvy beton Stanoveni objemove hmotnosti CSN EN 12350-6","search_en":"Fresh concrete Determination of density ČSN EN 12350-6","search_zh":"新拌混凝土 密度测定 ČSN EN 12350-6","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":26,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"2a7244fc998c2c30dca8dc06","lab_id":"69ad52a4de79e566650fd2da","country":"CZ","accr_number":"1195","accr_body":"ČIA","row_label":"8","test_object":"Beton świeży","test_object_en":"Fresh concrete","test_object_zh":"新拌混凝土","test_object_cs":"Čerstvý beton","methodology":"Oznaczanie konsystencji – metodą opadu stożka","methodology_en":"Determination of consistence – slump test","methodology_zh":"稠度测定——坍落度法","methodology_cs":"Stanovení konzistence – sednutím kužele","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie konsystencji – metodą opadu stożka","reference":"ČSN EN 12350-2","norm_bases":["ČSN EN 12350-2"],"lab_section":"1. Beroun","lab_section_en":"1. Beroun","lab_section_zh":"1. 贝龙","lab_section_cs":"1. Beroun","lab_address":"Areál cementárny, Beroun 660, 266 01 Beroun","regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Beton świeży Oznaczanie konsystencji – metodą opadu stożka Čerstvý beton Stanovení konzistence – sednutím kužele ČSN EN 12350-2 Beton swiezy Oznaczanie konsystencji – metoda opadu stozka Cerstvy beton Stanoveni konzistence – sednutim kuzele CSN EN 12350-2","search_en":"Fresh concrete Determination of consistence – slump test ČSN EN 12350-2","search_zh":"新拌混凝土 稠度测定——坍落度法 ČSN EN 12350-2","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":27,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"d97a1871ff07c55caf25c69b","lab_id":"69ad52a4de79e566650fd2da","country":"CZ","accr_number":"1195","accr_body":"ČIA","row_label":"8","test_object":"Beton świeży","test_object_en":"Fresh concrete","test_object_zh":"新拌混凝土","test_object_cs":"Čerstvý beton","methodology":"Oznaczanie konsystencji – metodą opadu stożka","methodology_en":"Determination of consistence – slump test","methodology_zh":"稠度测定——坍落度法","methodology_cs":"Stanovení konzistence – sednutím kužele","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie konsystencji – metodą opadu stożka","reference":"ČSN EN 12350-2","norm_bases":["ČSN EN 12350-2"],"lab_section":"2. Most","lab_section_en":"2. Most","lab_section_zh":"2. 莫斯特","lab_section_cs":"2. Most","lab_address":"Areál MAPECO Most, a.s., 434 01 Most – Čepirohy","regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Beton świeży Oznaczanie konsystencji – metodą opadu stożka Čerstvý beton Stanovení konzistence – sednutím kužele ČSN EN 12350-2 Beton swiezy Oznaczanie konsystencji – metoda opadu stozka Cerstvy beton Stanoveni konzistence – sednutim kuzele CSN EN 12350-2","search_en":"Fresh concrete Determination of consistence – slump test ČSN EN 12350-2","search_zh":"新拌混凝土 稠度测定——坍落度法 ČSN EN 12350-2","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":28,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"913e3301e8b7c80864a1f225","lab_id":"69ad52a4de79e566650fd2da","country":"CZ","accr_number":"1195","accr_body":"ČIA","row_label":"8","test_object":"Beton świeży","test_object_en":"Fresh concrete","test_object_zh":"新拌混凝土","test_object_cs":"Čerstvý beton","methodology":"Oznaczanie konsystencji – metodą opadu stożka","methodology_en":"Determination of consistence – slump test","methodology_zh":"稠度测定——坍落度法","methodology_cs":"Stanovení konzistence – sednutím kužele","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie konsystencji – metodą opadu stożka","reference":"ČSN EN 12350-2","norm_bases":["ČSN EN 12350-2"],"lab_section":"3. Trutnov","lab_section_en":"3. Trutnov","lab_section_zh":"3. 特鲁特诺夫","lab_section_cs":"3. Trutnov","lab_address":"Kalná Voda 77, 542 23 Mladé Buky","regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Beton świeży Oznaczanie konsystencji – metodą opadu stożka Čerstvý beton Stanovení konzistence – sednutím kužele ČSN EN 12350-2 Beton swiezy Oznaczanie konsystencji – metoda opadu stozka Cerstvy beton Stanoveni konzistence – sednutim kuzele CSN EN 12350-2","search_en":"Fresh concrete Determination of consistence – slump test ČSN EN 12350-2","search_zh":"新拌混凝土 稠度测定——坍落度法 ČSN EN 12350-2","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":29,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"ff333d1b8b00ff45aef2b512","lab_id":"69ad52a4de79e566650fd2da","country":"CZ","accr_number":"1195","accr_body":"ČIA","row_label":"8","test_object":"Beton świeży","test_object_en":"Fresh concrete","test_object_zh":"新拌混凝土","test_object_cs":"Čerstvý beton","methodology":"Oznaczanie konsystencji – metodą opadu stożka","methodology_en":"Determination of consistence – slump test","methodology_zh":"稠度测定——坍落度法","methodology_cs":"Stanovení konzistence – sednutím kužele","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie konsystencji – metodą opadu stożka","reference":"ČSN EN 12350-2","norm_bases":["ČSN EN 12350-2"],"lab_section":"4. Jindřichův Hradec","lab_section_en":"4. Jindřichův Hradec","lab_section_zh":"4. 因德日赫城","lab_section_cs":"4. Jindřichův Hradec","lab_address":"Jarošovská 2217/II, 377 01 Jindřichův Hradec","regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Beton świeży Oznaczanie konsystencji – metodą opadu stożka Čerstvý beton Stanovení konzistence – sednutím kužele ČSN EN 12350-2 Beton swiezy Oznaczanie konsystencji – metoda opadu stozka Cerstvy beton Stanoveni konzistence – sednutim kuzele CSN EN 12350-2","search_en":"Fresh concrete Determination of consistence – slump test ČSN EN 12350-2","search_zh":"新拌混凝土 稠度测定——坍落度法 ČSN EN 12350-2","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":30,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"a55999644e0fbe9e32408f0f","lab_id":"69ad52a4de79e566650fd2da","country":"CZ","accr_number":"1195","accr_body":"ČIA","row_label":"8","test_object":"Beton świeży","test_object_en":"Fresh concrete","test_object_zh":"新拌混凝土","test_object_cs":"Čerstvý beton","methodology":"Oznaczanie konsystencji – metodą opadu stożka","methodology_en":"Determination of consistence – slump test","methodology_zh":"稠度测定——坍落度法","methodology_cs":"Stanovení konzistence – sednutím kužele","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie konsystencji – metodą opadu stożka","reference":"ČSN EN 12350-2","norm_bases":["ČSN EN 12350-2"],"lab_section":"5. Klatovy","lab_section_en":"5. Klatovy","lab_section_zh":"5. 克拉托维","lab_section_cs":"5. Klatovy","lab_address":"Čertovka 890/2, 339 01 Klatovy","regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Beton świeży Oznaczanie konsystencji – metodą opadu stożka Čerstvý beton Stanovení konzistence – sednutím kužele ČSN EN 12350-2 Beton swiezy Oznaczanie konsystencji – metoda opadu stozka Cerstvy beton Stanoveni konzistence – sednutim kuzele CSN EN 12350-2","search_en":"Fresh concrete Determination of consistence – slump test ČSN EN 12350-2","search_zh":"新拌混凝土 稠度测定——坍落度法 ČSN EN 12350-2","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":31,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"03855879de9f8c2f9e46075f","lab_id":"69ad52a4de79e566650fd2da","country":"CZ","accr_number":"1195","accr_body":"ČIA","row_label":"8","test_object":"Beton świeży","test_object_en":"Fresh concrete","test_object_zh":"新拌混凝土","test_object_cs":"Čerstvý beton","methodology":"Oznaczanie konsystencji – metodą opadu stożka","methodology_en":"Determination of consistence – slump test","methodology_zh":"稠度测定——坍落度法","methodology_cs":"Stanovení konzistence – sednutím kužele","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie konsystencji – metodą opadu stożka","reference":"ČSN EN 12350-2","norm_bases":["ČSN EN 12350-2"],"lab_section":"6. Cheb","lab_section_en":"6. Cheb","lab_section_zh":"6. 海布","lab_section_cs":"6. Cheb","lab_address":"Karlovarská 40, 350 02 Cheb","regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Beton świeży Oznaczanie konsystencji – metodą opadu stożka Čerstvý beton Stanovení konzistence – sednutím kužele ČSN EN 12350-2 Beton swiezy Oznaczanie konsystencji – metoda opadu stozka Cerstvy beton Stanoveni konzistence – sednutim kuzele CSN EN 12350-2","search_en":"Fresh concrete Determination of consistence – slump test ČSN EN 12350-2","search_zh":"新拌混凝土 稠度测定——坍落度法 ČSN EN 12350-2","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":32,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"82bfb735d5ebb964817bf5a4","lab_id":"69ad52a4de79e566650fd2da","country":"CZ","accr_number":"1195","accr_body":"ČIA","row_label":"9","test_object":"Beton świeży","test_object_en":"Fresh concrete","test_object_zh":"新拌混凝土","test_object_cs":"Čerstvý beton","methodology":"Oznaczanie konsystencji – metodą stolika rozpływowego","methodology_en":"Determination of consistence – flow table test","methodology_zh":"稠度测定——扩展度法","methodology_cs":"Stanovení konzistence – rozlitím","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie konsystencji – metodą stolika rozpływowego","reference":"ČSN EN 12350-5","norm_bases":["ČSN EN 12350-5"],"lab_section":"1. Beroun","lab_section_en":"1. Beroun","lab_section_zh":"1. 贝龙","lab_section_cs":"1. Beroun","lab_address":"Areál cementárny, Beroun 660, 266 01 Beroun","regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Beton świeży Oznaczanie konsystencji – metodą stolika rozpływowego Čerstvý beton Stanovení konzistence – rozlitím ČSN EN 12350-5 Beton swiezy Oznaczanie konsystencji – metoda stolika rozplywowego Cerstvy beton Stanoveni konzistence – rozlitim CSN EN 12350-5","search_en":"Fresh concrete Determination of consistence – flow table test ČSN EN 12350-5","search_zh":"新拌混凝土 稠度测定——扩展度法 ČSN EN 12350-5","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":33,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"3882ab1176b0901e0361826a","lab_id":"69ad52a4de79e566650fd2da","country":"CZ","accr_number":"1195","accr_body":"ČIA","row_label":"9","test_object":"Beton świeży","test_object_en":"Fresh concrete","test_object_zh":"新拌混凝土","test_object_cs":"Čerstvý beton","methodology":"Oznaczanie konsystencji – metodą stolika rozpływowego","methodology_en":"Determination of consistence – flow table test","methodology_zh":"稠度测定——扩展度法","methodology_cs":"Stanovení konzistence – rozlitím","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie konsystencji – metodą stolika rozpływowego","reference":"ČSN EN 12350-5","norm_bases":["ČSN EN 12350-5"],"lab_section":"2. Most","lab_section_en":"2. Most","lab_section_zh":"2. 莫斯特","lab_section_cs":"2. Most","lab_address":"Areál MAPECO Most, a.s., 434 01 Most – Čepirohy","regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Beton świeży Oznaczanie konsystencji – metodą stolika rozpływowego Čerstvý beton Stanovení konzistence – rozlitím ČSN EN 12350-5 Beton swiezy Oznaczanie konsystencji – metoda stolika rozplywowego Cerstvy beton Stanoveni konzistence – rozlitim CSN EN 12350-5","search_en":"Fresh concrete Determination of consistence – flow table test ČSN EN 12350-5","search_zh":"新拌混凝土 稠度测定——扩展度法 ČSN EN 12350-5","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":34,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"9bd4b6552d0792d467642d07","lab_id":"69ad52a4de79e566650fd2da","country":"CZ","accr_number":"1195","accr_body":"ČIA","row_label":"9","test_object":"Beton świeży","test_object_en":"Fresh concrete","test_object_zh":"新拌混凝土","test_object_cs":"Čerstvý beton","methodology":"Oznaczanie konsystencji – metodą stolika rozpływowego","methodology_en":"Determination of consistence – flow table test","methodology_zh":"稠度测定——扩展度法","methodology_cs":"Stanovení konzistence – rozlitím","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie konsystencji – metodą stolika rozpływowego","reference":"ČSN EN 12350-5","norm_bases":["ČSN EN 12350-5"],"lab_section":"3. Trutnov","lab_section_en":"3. Trutnov","lab_section_zh":"3. 特鲁特诺夫","lab_section_cs":"3. Trutnov","lab_address":"Kalná Voda 77, 542 23 Mladé Buky","regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Beton świeży Oznaczanie konsystencji – metodą stolika rozpływowego Čerstvý beton Stanovení konzistence – rozlitím ČSN EN 12350-5 Beton swiezy Oznaczanie konsystencji – metoda stolika rozplywowego Cerstvy beton Stanoveni konzistence – rozlitim CSN EN 12350-5","search_en":"Fresh concrete Determination of consistence – flow table test ČSN EN 12350-5","search_zh":"新拌混凝土 稠度测定——扩展度法 ČSN EN 12350-5","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":35,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"a42bfdc8a0d4dfa2fe5d88be","lab_id":"69ad52a4de79e566650fd2da","country":"CZ","accr_number":"1195","accr_body":"ČIA","row_label":"9","test_object":"Beton świeży","test_object_en":"Fresh concrete","test_object_zh":"新拌混凝土","test_object_cs":"Čerstvý beton","methodology":"Oznaczanie konsystencji – metodą stolika rozpływowego","methodology_en":"Determination of consistence – flow table test","methodology_zh":"稠度测定——扩展度法","methodology_cs":"Stanovení konzistence – rozlitím","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie konsystencji – metodą stolika rozpływowego","reference":"ČSN EN 12350-5","norm_bases":["ČSN EN 12350-5"],"lab_section":"4. Jindřichův Hradec","lab_section_en":"4. Jindřichův Hradec","lab_section_zh":"4. 因德日赫城","lab_section_cs":"4. Jindřichův Hradec","lab_address":"Jarošovská 2217/II, 377 01 Jindřichův Hradec","regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Beton świeży Oznaczanie konsystencji – metodą stolika rozpływowego Čerstvý beton Stanovení konzistence – rozlitím ČSN EN 12350-5 Beton swiezy Oznaczanie konsystencji – metoda stolika rozplywowego Cerstvy beton Stanoveni konzistence – rozlitim CSN EN 12350-5","search_en":"Fresh concrete Determination of consistence – flow table test ČSN EN 12350-5","search_zh":"新拌混凝土 稠度测定——扩展度法 ČSN EN 12350-5","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":36,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"860cc3ebf745e62641a9b9e1","lab_id":"69ad52a4de79e566650fd2da","country":"CZ","accr_number":"1195","accr_body":"ČIA","row_label":"9","test_object":"Beton świeży","test_object_en":"Fresh concrete","test_object_zh":"新拌混凝土","test_object_cs":"Čerstvý beton","methodology":"Oznaczanie konsystencji – metodą stolika rozpływowego","methodology_en":"Determination of consistence – flow table test","methodology_zh":"稠度测定——扩展度法","methodology_cs":"Stanovení konzistence – rozlitím","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie konsystencji – metodą stolika rozpływowego","reference":"ČSN EN 12350-5","norm_bases":["ČSN EN 12350-5"],"lab_section":"5. Klatovy","lab_section_en":"5. Klatovy","lab_section_zh":"5. 克拉托维","lab_section_cs":"5. Klatovy","lab_address":"Čertovka 890/2, 339 01 Klatovy","regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Beton świeży Oznaczanie konsystencji – metodą stolika rozpływowego Čerstvý beton Stanovení konzistence – rozlitím ČSN EN 12350-5 Beton swiezy Oznaczanie konsystencji – metoda stolika rozplywowego Cerstvy beton Stanoveni konzistence – rozlitim CSN EN 12350-5","search_en":"Fresh concrete Determination of consistence – flow table test ČSN EN 12350-5","search_zh":"新拌混凝土 稠度测定——扩展度法 ČSN EN 12350-5","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":37,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"79cd694d8cddc1c473d16ea9","lab_id":"69ad52a4de79e566650fd2da","country":"CZ","accr_number":"1195","accr_body":"ČIA","row_label":"9","test_object":"Beton świeży","test_object_en":"Fresh concrete","test_object_zh":"新拌混凝土","test_object_cs":"Čerstvý beton","methodology":"Oznaczanie konsystencji – metodą stolika rozpływowego","methodology_en":"Determination of consistence – flow table test","methodology_zh":"稠度测定——扩展度法","methodology_cs":"Stanovení konzistence – rozlitím","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie konsystencji – metodą stolika rozpływowego","reference":"ČSN EN 12350-5","norm_bases":["ČSN EN 12350-5"],"lab_section":"6. Cheb","lab_section_en":"6. Cheb","lab_section_zh":"6. 海布","lab_section_cs":"6. Cheb","lab_address":"Karlovarská 40, 350 02 Cheb","regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Beton świeży Oznaczanie konsystencji – metodą stolika rozpływowego Čerstvý beton Stanovení konzistence – rozlitím ČSN EN 12350-5 Beton swiezy Oznaczanie konsystencji – metoda stolika rozplywowego Cerstvy beton Stanoveni konzistence – rozlitim CSN EN 12350-5","search_en":"Fresh concrete Determination of consistence – flow table test ČSN EN 12350-5","search_zh":"新拌混凝土 稠度测定——扩展度法 ČSN EN 12350-5","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":38,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"79be598f49620171e75bdbb0","lab_id":"69ad52a4de79e566650fd2da","country":"CZ","accr_number":"1195","accr_body":"ČIA","row_label":"10","test_object":"Beton świeży","test_object_en":"Fresh concrete","test_object_zh":"新拌混凝土","test_object_cs":"Čerstvý beton","methodology":"Oznaczanie zawartości powietrza – metoda ciśnieniowa","methodology_en":"Determination of air content – pressure gauge method","methodology_zh":"含气量测定——压力计法","methodology_cs":"Stanovení obsahu vzduchu – tlakoměrná metoda","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości powietrza – metoda ciśnieniowa","reference":"ČSN EN 12350-7","norm_bases":["ČSN EN 12350-7"],"lab_section":"1. Beroun","lab_section_en":"1. Beroun","lab_section_zh":"1. 贝龙","lab_section_cs":"1. Beroun","lab_address":"Areál cementárny, Beroun 660, 266 01 Beroun","regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Beton świeży Oznaczanie zawartości powietrza – metoda ciśnieniowa Čerstvý beton Stanovení obsahu vzduchu – tlakoměrná metoda ČSN EN 12350-7 Beton swiezy Oznaczanie zawartosci powietrza – metoda cisnieniowa Cerstvy beton Stanoveni obsahu vzduchu – tlakomerna metoda CSN EN 12350-7","search_en":"Fresh concrete Determination of air content – pressure gauge method ČSN EN 12350-7","search_zh":"新拌混凝土 含气量测定——压力计法 ČSN EN 12350-7","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":39,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"b21af916b2a822ed6e1e9446","lab_id":"69ad52a4de79e566650fd2da","country":"CZ","accr_number":"1195","accr_body":"ČIA","row_label":"10","test_object":"Beton świeży","test_object_en":"Fresh concrete","test_object_zh":"新拌混凝土","test_object_cs":"Čerstvý beton","methodology":"Oznaczanie zawartości powietrza – metoda ciśnieniowa","methodology_en":"Determination of air content – pressure gauge method","methodology_zh":"含气量测定——压力计法","methodology_cs":"Stanovení obsahu vzduchu – tlakoměrná metoda","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości powietrza – metoda ciśnieniowa","reference":"ČSN EN 12350-7","norm_bases":["ČSN EN 12350-7"],"lab_section":"2. Most","lab_section_en":"2. Most","lab_section_zh":"2. 莫斯特","lab_section_cs":"2. Most","lab_address":"Areál MAPECO Most, a.s., 434 01 Most – Čepirohy","regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Beton świeży Oznaczanie zawartości powietrza – metoda ciśnieniowa Čerstvý beton Stanovení obsahu vzduchu – tlakoměrná metoda ČSN EN 12350-7 Beton swiezy Oznaczanie zawartosci powietrza – metoda cisnieniowa Cerstvy beton Stanoveni obsahu vzduchu – tlakomerna metoda CSN EN 12350-7","search_en":"Fresh concrete Determination of air content – pressure gauge method ČSN EN 12350-7","search_zh":"新拌混凝土 含气量测定——压力计法 ČSN EN 12350-7","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":40,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"5dce05259ad092aecd277f5a","lab_id":"69ad52a4de79e566650fd2da","country":"CZ","accr_number":"1195","accr_body":"ČIA","row_label":"10","test_object":"Beton świeży","test_object_en":"Fresh concrete","test_object_zh":"新拌混凝土","test_object_cs":"Čerstvý beton","methodology":"Oznaczanie zawartości powietrza – metoda ciśnieniowa","methodology_en":"Determination of air content – pressure gauge method","methodology_zh":"含气量测定——压力计法","methodology_cs":"Stanovení obsahu vzduchu – tlakoměrná metoda","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości powietrza – metoda ciśnieniowa","reference":"ČSN EN 12350-7","norm_bases":["ČSN EN 12350-7"],"lab_section":"3. Trutnov","lab_section_en":"3. Trutnov","lab_section_zh":"3. 特鲁特诺夫","lab_section_cs":"3. Trutnov","lab_address":"Kalná Voda 77, 542 23 Mladé Buky","regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Beton świeży Oznaczanie zawartości powietrza – metoda ciśnieniowa Čerstvý beton Stanovení obsahu vzduchu – tlakoměrná metoda ČSN EN 12350-7 Beton swiezy Oznaczanie zawartosci powietrza – metoda cisnieniowa Cerstvy beton Stanoveni obsahu vzduchu – tlakomerna metoda CSN EN 12350-7","search_en":"Fresh concrete Determination of air content – pressure gauge method ČSN EN 12350-7","search_zh":"新拌混凝土 含气量测定——压力计法 ČSN EN 12350-7","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":41,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"1b53af6ea267b218ef1e62e4","lab_id":"69ad52a4de79e566650fd2da","country":"CZ","accr_number":"1195","accr_body":"ČIA","row_label":"10","test_object":"Beton świeży","test_object_en":"Fresh concrete","test_object_zh":"新拌混凝土","test_object_cs":"Čerstvý beton","methodology":"Oznaczanie zawartości powietrza – metoda ciśnieniowa","methodology_en":"Determination of air content – pressure gauge method","methodology_zh":"含气量测定——压力计法","methodology_cs":"Stanovení obsahu vzduchu – tlakoměrná metoda","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości powietrza – metoda ciśnieniowa","reference":"ČSN EN 12350-7","norm_bases":["ČSN EN 12350-7"],"lab_section":"4. Jindřichův Hradec","lab_section_en":"4. Jindřichův Hradec","lab_section_zh":"4. 因德日赫城","lab_section_cs":"4. Jindřichův Hradec","lab_address":"Jarošovská 2217/II, 377 01 Jindřichův Hradec","regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Beton świeży Oznaczanie zawartości powietrza – metoda ciśnieniowa Čerstvý beton Stanovení obsahu vzduchu – tlakoměrná metoda ČSN EN 12350-7 Beton swiezy Oznaczanie zawartosci powietrza – metoda cisnieniowa Cerstvy beton Stanoveni obsahu vzduchu – tlakomerna metoda CSN EN 12350-7","search_en":"Fresh concrete Determination of air content – pressure gauge method ČSN EN 12350-7","search_zh":"新拌混凝土 含气量测定——压力计法 ČSN EN 12350-7","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":42,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"3ce720b6c6d1ebc5872c8ffc","lab_id":"69ad52a4de79e566650fd2da","country":"CZ","accr_number":"1195","accr_body":"ČIA","row_label":"10","test_object":"Beton świeży","test_object_en":"Fresh concrete","test_object_zh":"新拌混凝土","test_object_cs":"Čerstvý beton","methodology":"Oznaczanie zawartości powietrza – metoda ciśnieniowa","methodology_en":"Determination of air content – pressure gauge method","methodology_zh":"含气量测定——压力计法","methodology_cs":"Stanovení obsahu vzduchu – tlakoměrná metoda","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości powietrza – metoda ciśnieniowa","reference":"ČSN EN 12350-7","norm_bases":["ČSN EN 12350-7"],"lab_section":"5. Klatovy","lab_section_en":"5. Klatovy","lab_section_zh":"5. 克拉托维","lab_section_cs":"5. Klatovy","lab_address":"Čertovka 890/2, 339 01 Klatovy","regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Beton świeży Oznaczanie zawartości powietrza – metoda ciśnieniowa Čerstvý beton Stanovení obsahu vzduchu – tlakoměrná metoda ČSN EN 12350-7 Beton swiezy Oznaczanie zawartosci powietrza – metoda cisnieniowa Cerstvy beton Stanoveni obsahu vzduchu – tlakomerna metoda CSN EN 12350-7","search_en":"Fresh concrete Determination of air content – pressure gauge method ČSN EN 12350-7","search_zh":"新拌混凝土 含气量测定——压力计法 ČSN EN 12350-7","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":43,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"eebe070fabf80b6928d3d9e2","lab_id":"69ad52a4de79e566650fd2da","country":"CZ","accr_number":"1195","accr_body":"ČIA","row_label":"10","test_object":"Beton świeży","test_object_en":"Fresh concrete","test_object_zh":"新拌混凝土","test_object_cs":"Čerstvý beton","methodology":"Oznaczanie zawartości powietrza – metoda ciśnieniowa","methodology_en":"Determination of air content – pressure gauge method","methodology_zh":"含气量测定——压力计法","methodology_cs":"Stanovení obsahu vzduchu – tlakoměrná metoda","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości powietrza – metoda ciśnieniowa","reference":"ČSN EN 12350-7","norm_bases":["ČSN EN 12350-7"],"lab_section":"6. Cheb","lab_section_en":"6. Cheb","lab_section_zh":"6. 海布","lab_section_cs":"6. Cheb","lab_address":"Karlovarská 40, 350 02 Cheb","regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Beton świeży Oznaczanie zawartości powietrza – metoda ciśnieniowa Čerstvý beton Stanovení obsahu vzduchu – tlakoměrná metoda ČSN EN 12350-7 Beton swiezy Oznaczanie zawartosci powietrza – metoda cisnieniowa Cerstvy beton Stanoveni obsahu vzduchu – tlakomerna metoda CSN EN 12350-7","search_en":"Fresh concrete Determination of air content – pressure gauge method ČSN EN 12350-7","search_zh":"新拌混凝土 含气量测定——压力计法 ČSN EN 12350-7","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":44,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"5da1279bc7c7f2689842d27f","lab_id":"69ad52a4de79e566650fd2da","country":"CZ","accr_number":"1195","accr_body":"ČIA","row_label":"11","test_object":"Beton stwardniały","test_object_en":"Hardened concrete","test_object_zh":"硬化混凝土","test_object_cs":"Ztvrdlý beton","methodology":"Oznaczanie gęstości","methodology_en":"Determination of density","methodology_zh":"密度测定","methodology_cs":"Stanovení objemové hmotnosti","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie gęstości","reference":"ČSN EN 12390-7, mimo čl. 6.5","norm_bases":["ČSN EN 12390-7, mimo čl. 6.5"],"lab_section":"1. Beroun","lab_section_en":"1. Beroun","lab_section_zh":"1. 贝龙","lab_section_cs":"1. Beroun","lab_address":"Areál cementárny, Beroun 660, 266 01 Beroun","regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Beton stwardniały Oznaczanie gęstości Ztvrdlý beton Stanovení objemové hmotnosti ČSN EN 12390-7, mimo čl. 6.5 Beton stwardnialy Oznaczanie gestosci Ztvrdly beton Stanoveni objemove hmotnosti CSN EN 12390-7, mimo cl. 6.5","search_en":"Hardened concrete Determination of density ČSN EN 12390-7, mimo čl. 6.5","search_zh":"硬化混凝土 密度测定 ČSN EN 12390-7, mimo čl. 6.5","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":45,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"76b74704de146c17afb6952f","lab_id":"69ad52a4de79e566650fd2da","country":"CZ","accr_number":"1195","accr_body":"ČIA","row_label":"11","test_object":"Beton stwardniały","test_object_en":"Hardened concrete","test_object_zh":"硬化混凝土","test_object_cs":"Ztvrdlý beton","methodology":"Oznaczanie gęstości","methodology_en":"Determination of density","methodology_zh":"密度测定","methodology_cs":"Stanovení objemové hmotnosti","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie gęstości","reference":"ČSN EN 12390-7, mimo čl. 6.5","norm_bases":["ČSN EN 12390-7, mimo čl. 6.5"],"lab_section":"2. Most","lab_section_en":"2. Most","lab_section_zh":"2. 莫斯特","lab_section_cs":"2. Most","lab_address":"Areál MAPECO Most, a.s., 434 01 Most – Čepirohy","regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Beton stwardniały Oznaczanie gęstości Ztvrdlý beton Stanovení objemové hmotnosti ČSN EN 12390-7, mimo čl. 6.5 Beton stwardnialy Oznaczanie gestosci Ztvrdly beton Stanoveni objemove hmotnosti CSN EN 12390-7, mimo cl. 6.5","search_en":"Hardened concrete Determination of density ČSN EN 12390-7, mimo čl. 6.5","search_zh":"硬化混凝土 密度测定 ČSN EN 12390-7, mimo čl. 6.5","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":46,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"7ed23dd0c94c186f11641456","lab_id":"69ad52a4de79e566650fd2da","country":"CZ","accr_number":"1195","accr_body":"ČIA","row_label":"11","test_object":"Beton stwardniały","test_object_en":"Hardened concrete","test_object_zh":"硬化混凝土","test_object_cs":"Ztvrdlý beton","methodology":"Oznaczanie gęstości","methodology_en":"Determination of density","methodology_zh":"密度测定","methodology_cs":"Stanovení objemové hmotnosti","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie gęstości","reference":"ČSN EN 12390-7, mimo čl. 6.5","norm_bases":["ČSN EN 12390-7, mimo čl. 6.5"],"lab_section":"3. Trutnov","lab_section_en":"3. Trutnov","lab_section_zh":"3. 特鲁特诺夫","lab_section_cs":"3. Trutnov","lab_address":"Kalná Voda 77, 542 23 Mladé Buky","regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Beton stwardniały Oznaczanie gęstości Ztvrdlý beton Stanovení objemové hmotnosti ČSN EN 12390-7, mimo čl. 6.5 Beton stwardnialy Oznaczanie gestosci Ztvrdly beton Stanoveni objemove hmotnosti CSN EN 12390-7, mimo cl. 6.5","search_en":"Hardened concrete Determination of density ČSN EN 12390-7, mimo čl. 6.5","search_zh":"硬化混凝土 密度测定 ČSN EN 12390-7, mimo čl. 6.5","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":47,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"6b7bc6714853669db40b2709","lab_id":"69ad52a4de79e566650fd2da","country":"CZ","accr_number":"1195","accr_body":"ČIA","row_label":"11","test_object":"Beton stwardniały","test_object_en":"Hardened concrete","test_object_zh":"硬化混凝土","test_object_cs":"Ztvrdlý beton","methodology":"Oznaczanie gęstości","methodology_en":"Determination of density","methodology_zh":"密度测定","methodology_cs":"Stanovení objemové hmotnosti","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie gęstości","reference":"ČSN EN 12390-7, mimo čl. 6.5","norm_bases":["ČSN EN 12390-7, mimo čl. 6.5"],"lab_section":"4. Jindřichův Hradec","lab_section_en":"4. Jindřichův Hradec","lab_section_zh":"4. 因德日赫城","lab_section_cs":"4. Jindřichův Hradec","lab_address":"Jarošovská 2217/II, 377 01 Jindřichův Hradec","regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Beton stwardniały Oznaczanie gęstości Ztvrdlý beton Stanovení objemové hmotnosti ČSN EN 12390-7, mimo čl. 6.5 Beton stwardnialy Oznaczanie gestosci Ztvrdly beton Stanoveni objemove hmotnosti CSN EN 12390-7, mimo cl. 6.5","search_en":"Hardened concrete Determination of density ČSN EN 12390-7, mimo čl. 6.5","search_zh":"硬化混凝土 密度测定 ČSN EN 12390-7, mimo čl. 6.5","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":48,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"6169a263073f47a078c6e4db","lab_id":"69ad52a4de79e566650fd2da","country":"CZ","accr_number":"1195","accr_body":"ČIA","row_label":"11","test_object":"Beton stwardniały","test_object_en":"Hardened concrete","test_object_zh":"硬化混凝土","test_object_cs":"Ztvrdlý beton","methodology":"Oznaczanie gęstości","methodology_en":"Determination of density","methodology_zh":"密度测定","methodology_cs":"Stanovení objemové hmotnosti","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie gęstości","reference":"ČSN EN 12390-7, mimo čl. 6.5","norm_bases":["ČSN EN 12390-7, mimo čl. 6.5"],"lab_section":"5. Klatovy","lab_section_en":"5. Klatovy","lab_section_zh":"5. 克拉托维","lab_section_cs":"5. Klatovy","lab_address":"Čertovka 890/2, 339 01 Klatovy","regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Beton stwardniały Oznaczanie gęstości Ztvrdlý beton Stanovení objemové hmotnosti ČSN EN 12390-7, mimo čl. 6.5 Beton stwardnialy Oznaczanie gestosci Ztvrdly beton Stanoveni objemove hmotnosti CSN EN 12390-7, mimo cl. 6.5","search_en":"Hardened concrete Determination of density ČSN EN 12390-7, mimo čl. 6.5","search_zh":"硬化混凝土 密度测定 ČSN EN 12390-7, mimo čl. 6.5","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":49,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"6da271b75c148160f5ef3e39","lab_id":"69ad52a4de79e566650fd2da","country":"CZ","accr_number":"1195","accr_body":"ČIA","row_label":"11","test_object":"Beton stwardniały","test_object_en":"Hardened concrete","test_object_zh":"硬化混凝土","test_object_cs":"Ztvrdlý beton","methodology":"Oznaczanie gęstości","methodology_en":"Determination of density","methodology_zh":"密度测定","methodology_cs":"Stanovení objemové hmotnosti","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie gęstości","reference":"ČSN EN 12390-7, mimo čl. 6.5","norm_bases":["ČSN EN 12390-7, mimo čl. 6.5"],"lab_section":"6. Cheb","lab_section_en":"6. Cheb","lab_section_zh":"6. 海布","lab_section_cs":"6. Cheb","lab_address":"Karlovarská 40, 350 02 Cheb","regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Beton stwardniały Oznaczanie gęstości Ztvrdlý beton Stanovení objemové hmotnosti ČSN EN 12390-7, mimo čl. 6.5 Beton stwardnialy Oznaczanie gestosci Ztvrdly beton Stanoveni objemove hmotnosti CSN EN 12390-7, mimo cl. 6.5","search_en":"Hardened concrete Determination of density ČSN EN 12390-7, mimo čl. 6.5","search_zh":"硬化混凝土 密度测定 ČSN EN 12390-7, mimo čl. 6.5","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":50,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"c0f9db4308bcc3b177e79572","lab_id":"69ad52a4de79e566650fd2da","country":"CZ","accr_number":"1195","accr_body":"ČIA","row_label":"12","test_object":"Beton stwardniały","test_object_en":"Hardened concrete","test_object_zh":"硬化混凝土","test_object_cs":"Ztvrdlý beton","methodology":"Oznaczanie wytrzymałości na ściskanie","methodology_en":"Determination of compressive strength","methodology_zh":"抗压强度测定","methodology_cs":"Stanovení pevnosti v tlaku","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie wytrzymałości na ściskanie","reference":"ČSN EN 12390-3, mimo příl. A","norm_bases":["ČSN EN 12390-3, mimo příl. A"],"lab_section":"1. Beroun","lab_section_en":"1. Beroun","lab_section_zh":"1. 贝龙","lab_section_cs":"1. Beroun","lab_address":"Areál cementárny, Beroun 660, 266 01 Beroun","regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Beton stwardniały Oznaczanie wytrzymałości na ściskanie Ztvrdlý beton Stanovení pevnosti v tlaku ČSN EN 12390-3, mimo příl. A Beton stwardnialy Oznaczanie wytrzymalosci na sciskanie Ztvrdly beton Stanoveni pevnosti v tlaku CSN EN 12390-3, mimo pril. A","search_en":"Hardened concrete Determination of compressive strength ČSN EN 12390-3, mimo příl. A","search_zh":"硬化混凝土 抗压强度测定 ČSN EN 12390-3, mimo příl. A","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":51,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"40b12229771fd44d4d241bc7","lab_id":"69ad52a4de79e566650fd2da","country":"CZ","accr_number":"1195","accr_body":"ČIA","row_label":"12","test_object":"Beton stwardniały","test_object_en":"Hardened concrete","test_object_zh":"硬化混凝土","test_object_cs":"Ztvrdlý beton","methodology":"Oznaczanie wytrzymałości na ściskanie","methodology_en":"Determination of compressive strength","methodology_zh":"抗压强度测定","methodology_cs":"Stanovení pevnosti v tlaku","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie wytrzymałości na ściskanie","reference":"ČSN EN 12390-3, mimo příl. A","norm_bases":["ČSN EN 12390-3, mimo příl. A"],"lab_section":"2. Most","lab_section_en":"2. Most","lab_section_zh":"2. 莫斯特","lab_section_cs":"2. Most","lab_address":"Areál MAPECO Most, a.s., 434 01 Most – Čepirohy","regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Beton stwardniały Oznaczanie wytrzymałości na ściskanie Ztvrdlý beton Stanovení pevnosti v tlaku ČSN EN 12390-3, mimo příl. A Beton stwardnialy Oznaczanie wytrzymalosci na sciskanie Ztvrdly beton Stanoveni pevnosti v tlaku CSN EN 12390-3, mimo pril. A","search_en":"Hardened concrete Determination of compressive strength ČSN EN 12390-3, mimo příl. A","search_zh":"硬化混凝土 抗压强度测定 ČSN EN 12390-3, mimo příl. A","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":52,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"3ed725cc1ca5b0c6fc84dd2b","lab_id":"69ad52a4de79e566650fd2da","country":"CZ","accr_number":"1195","accr_body":"ČIA","row_label":"12","test_object":"Beton stwardniały","test_object_en":"Hardened concrete","test_object_zh":"硬化混凝土","test_object_cs":"Ztvrdlý beton","methodology":"Oznaczanie wytrzymałości na ściskanie","methodology_en":"Determination of compressive strength","methodology_zh":"抗压强度测定","methodology_cs":"Stanovení pevnosti v tlaku","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie wytrzymałości na ściskanie","reference":"ČSN EN 12390-3, mimo příl. A","norm_bases":["ČSN EN 12390-3, mimo příl. A"],"lab_section":"3. Trutnov","lab_section_en":"3. Trutnov","lab_section_zh":"3. 特鲁特诺夫","lab_section_cs":"3. Trutnov","lab_address":"Kalná Voda 77, 542 23 Mladé Buky","regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Beton stwardniały Oznaczanie wytrzymałości na ściskanie Ztvrdlý beton Stanovení pevnosti v tlaku ČSN EN 12390-3, mimo příl. A Beton stwardnialy Oznaczanie wytrzymalosci na sciskanie Ztvrdly beton Stanoveni pevnosti v tlaku CSN EN 12390-3, mimo pril. A","search_en":"Hardened concrete Determination of compressive strength ČSN EN 12390-3, mimo příl. A","search_zh":"硬化混凝土 抗压强度测定 ČSN EN 12390-3, mimo příl. A","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":53,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"3ff794945ef8dfae56f416cf","lab_id":"69ad52a4de79e566650fd2da","country":"CZ","accr_number":"1195","accr_body":"ČIA","row_label":"12","test_object":"Beton stwardniały","test_object_en":"Hardened concrete","test_object_zh":"硬化混凝土","test_object_cs":"Ztvrdlý beton","methodology":"Oznaczanie wytrzymałości na ściskanie","methodology_en":"Determination of compressive strength","methodology_zh":"抗压强度测定","methodology_cs":"Stanovení pevnosti v tlaku","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie wytrzymałości na ściskanie","reference":"ČSN EN 12390-3, mimo příl. A","norm_bases":["ČSN EN 12390-3, mimo příl. A"],"lab_section":"4. Jindřichův Hradec","lab_section_en":"4. Jindřichův Hradec","lab_section_zh":"4. 因德日赫城","lab_section_cs":"4. Jindřichův Hradec","lab_address":"Jarošovská 2217/II, 377 01 Jindřichův Hradec","regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Beton stwardniały Oznaczanie wytrzymałości na ściskanie Ztvrdlý beton Stanovení pevnosti v tlaku ČSN EN 12390-3, mimo příl. A Beton stwardnialy Oznaczanie wytrzymalosci na sciskanie Ztvrdly beton Stanoveni pevnosti v tlaku CSN EN 12390-3, mimo pril. A","search_en":"Hardened concrete Determination of compressive strength ČSN EN 12390-3, mimo příl. A","search_zh":"硬化混凝土 抗压强度测定 ČSN EN 12390-3, mimo příl. A","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":54,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"2202724ea0fa40af9d8cd412","lab_id":"69ad52a4de79e566650fd2da","country":"CZ","accr_number":"1195","accr_body":"ČIA","row_label":"12","test_object":"Beton stwardniały","test_object_en":"Hardened concrete","test_object_zh":"硬化混凝土","test_object_cs":"Ztvrdlý beton","methodology":"Oznaczanie wytrzymałości na ściskanie","methodology_en":"Determination of compressive strength","methodology_zh":"抗压强度测定","methodology_cs":"Stanovení pevnosti v tlaku","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie wytrzymałości na ściskanie","reference":"ČSN EN 12390-3, mimo příl. A","norm_bases":["ČSN EN 12390-3, mimo příl. A"],"lab_section":"5. Klatovy","lab_section_en":"5. Klatovy","lab_section_zh":"5. 克拉托维","lab_section_cs":"5. Klatovy","lab_address":"Čertovka 890/2, 339 01 Klatovy","regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Beton stwardniały Oznaczanie wytrzymałości na ściskanie Ztvrdlý beton Stanovení pevnosti v tlaku ČSN EN 12390-3, mimo příl. A Beton stwardnialy Oznaczanie wytrzymalosci na sciskanie Ztvrdly beton Stanoveni pevnosti v tlaku CSN EN 12390-3, mimo pril. A","search_en":"Hardened concrete Determination of compressive strength ČSN EN 12390-3, mimo příl. A","search_zh":"硬化混凝土 抗压强度测定 ČSN EN 12390-3, mimo příl. A","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":55,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"603fcecc55fa36363ee6cdf9","lab_id":"69ad52a4de79e566650fd2da","country":"CZ","accr_number":"1195","accr_body":"ČIA","row_label":"12","test_object":"Beton stwardniały","test_object_en":"Hardened concrete","test_object_zh":"硬化混凝土","test_object_cs":"Ztvrdlý beton","methodology":"Oznaczanie wytrzymałości na ściskanie","methodology_en":"Determination of compressive strength","methodology_zh":"抗压强度测定","methodology_cs":"Stanovení pevnosti v tlaku","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie wytrzymałości na ściskanie","reference":"ČSN EN 12390-3, mimo příl. A","norm_bases":["ČSN EN 12390-3, mimo příl. A"],"lab_section":"6. Cheb","lab_section_en":"6. Cheb","lab_section_zh":"6. 海布","lab_section_cs":"6. Cheb","lab_address":"Karlovarská 40, 350 02 Cheb","regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Beton stwardniały Oznaczanie wytrzymałości na ściskanie Ztvrdlý beton Stanovení pevnosti v tlaku ČSN EN 12390-3, mimo příl. A Beton stwardnialy Oznaczanie wytrzymalosci na sciskanie Ztvrdly beton Stanoveni pevnosti v tlaku CSN EN 12390-3, mimo pril. A","search_en":"Hardened concrete Determination of compressive strength ČSN EN 12390-3, mimo příl. A","search_zh":"硬化混凝土 抗压强度测定 ČSN EN 12390-3, mimo příl. A","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":56,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"209b568c429766aca81209ca","lab_id":"69ad52a4de79e566650fd2da","country":"CZ","accr_number":"1195","accr_body":"ČIA","row_label":"13","test_object":"Beton stwardniały","test_object_en":"Hardened concrete","test_object_zh":"硬化混凝土","test_object_cs":"Ztvrdlý beton","methodology":"Oznaczanie wytrzymałości na rozciąganie przy zginaniu","methodology_en":"Determination of flexural tensile strength","methodology_zh":"弯拉强度测定","methodology_cs":"Stanovení pevnosti v tahu ohybem","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie wytrzymałości na rozciąganie przy zginaniu","reference":"ČSN EN 12390-5","norm_bases":["ČSN EN 12390-5"],"lab_section":"1. Beroun","lab_section_en":"1. Beroun","lab_section_zh":"1. 贝龙","lab_section_cs":"1. Beroun","lab_address":"Areál cementárny, Beroun 660, 266 01 Beroun","regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Beton stwardniały Oznaczanie wytrzymałości na rozciąganie przy zginaniu Ztvrdlý beton Stanovení pevnosti v tahu ohybem ČSN EN 12390-5 Beton stwardnialy Oznaczanie wytrzymalosci na rozciaganie przy zginaniu Ztvrdly beton Stanoveni pevnosti v tahu ohybem CSN EN 12390-5","search_en":"Hardened concrete Determination of flexural tensile strength ČSN EN 12390-5","search_zh":"硬化混凝土 弯拉强度测定 ČSN EN 12390-5","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":57,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"c69a19b04df2f33d62dba320","lab_id":"69ad52a4de79e566650fd2da","country":"CZ","accr_number":"1195","accr_body":"ČIA","row_label":"14","test_object":"Beton stwardniały","test_object_en":"Hardened concrete","test_object_zh":"硬化混凝土","test_object_cs":"Ztvrdlý beton","methodology":"Oznaczanie mrozoodporności","methodology_en":"Determination of frost resistance","methodology_zh":"抗冻性测定","methodology_cs":"Stanovení mrazuvzdornosti","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie mrozoodporności","reference":"ČSN 73 1322","norm_bases":["ČSN 73 1322"],"lab_section":"1. Beroun","lab_section_en":"1. Beroun","lab_section_zh":"1. 贝龙","lab_section_cs":"1. Beroun","lab_address":"Areál cementárny, Beroun 660, 266 01 Beroun","regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Beton stwardniały Oznaczanie mrozoodporności Ztvrdlý beton Stanovení mrazuvzdornosti ČSN 73 1322 Beton stwardnialy Oznaczanie mrozoodpornosci Ztvrdly beton Stanoveni mrazuvzdornosti CSN 73 1322","search_en":"Hardened concrete Determination of frost resistance ČSN 73 1322","search_zh":"硬化混凝土 抗冻性测定 ČSN 73 1322","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":58,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"07e5b22f1269a552ce494350","lab_id":"69ad52a4de79e566650fd2da","country":"CZ","accr_number":"1195","accr_body":"ČIA","row_label":"15","test_object":"Beton stwardniały","test_object_en":"Hardened concrete","test_object_zh":"硬化混凝土","test_object_cs":"Ztvrdlý beton","methodology":"Oznaczanie głębokości penetracji wody pod ciśnieniem","methodology_en":"Determination of depth of penetration of water under pressure","methodology_zh":"压力水渗透深度测定","methodology_cs":"Stanovení hloubky průsaku tlakové vody","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie głębokości penetracji wody pod ciśnieniem","reference":"ČSN EN 12390-8","norm_bases":["ČSN EN 12390-8"],"lab_section":"1. Beroun","lab_section_en":"1. Beroun","lab_section_zh":"1. 贝龙","lab_section_cs":"1. Beroun","lab_address":"Areál cementárny, Beroun 660, 266 01 Beroun","regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Beton stwardniały Oznaczanie głębokości penetracji wody pod ciśnieniem Ztvrdlý beton Stanovení hloubky průsaku tlakové vody ČSN EN 12390-8 Beton stwardnialy Oznaczanie glebokosci penetracji wody pod cisnieniem Ztvrdly beton Stanoveni hloubky prusaku tlakove vody CSN EN 12390-8","search_en":"Hardened concrete Determination of depth of penetration of water under pressure ČSN EN 12390-8","search_zh":"硬化混凝土 压力水渗透深度测定 ČSN EN 12390-8","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":59,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"4ca7233ee708968f306a7e8a","lab_id":"69ad52a4de79e566650fd2da","country":"CZ","accr_number":"1195","accr_body":"ČIA","row_label":"15","test_object":"Beton stwardniały","test_object_en":"Hardened concrete","test_object_zh":"硬化混凝土","test_object_cs":"Ztvrdlý beton","methodology":"Oznaczanie głębokości penetracji wody pod ciśnieniem","methodology_en":"Determination of depth of penetration of water under pressure","methodology_zh":"压力水渗透深度测定","methodology_cs":"Stanovení hloubky průsaku tlakové vody","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie głębokości penetracji wody pod ciśnieniem","reference":"ČSN EN 12390-8","norm_bases":["ČSN EN 12390-8"],"lab_section":"2. Most","lab_section_en":"2. Most","lab_section_zh":"2. 莫斯特","lab_section_cs":"2. Most","lab_address":"Areál MAPECO Most, a.s., 434 01 Most – Čepirohy","regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Beton stwardniały Oznaczanie głębokości penetracji wody pod ciśnieniem Ztvrdlý beton Stanovení hloubky průsaku tlakové vody ČSN EN 12390-8 Beton stwardnialy Oznaczanie glebokosci penetracji wody pod cisnieniem Ztvrdly beton Stanoveni hloubky prusaku tlakove vody CSN EN 12390-8","search_en":"Hardened concrete Determination of depth of penetration of water under pressure ČSN EN 12390-8","search_zh":"硬化混凝土 压力水渗透深度测定 ČSN EN 12390-8","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":60,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"3c5f92f96f2d6b9f0200cd14","lab_id":"69ad52a4de79e566650fd2da","country":"CZ","accr_number":"1195","accr_body":"ČIA","row_label":"15","test_object":"Beton stwardniały","test_object_en":"Hardened concrete","test_object_zh":"硬化混凝土","test_object_cs":"Ztvrdlý beton","methodology":"Oznaczanie głębokości penetracji wody pod ciśnieniem","methodology_en":"Determination of depth of penetration of water under pressure","methodology_zh":"压力水渗透深度测定","methodology_cs":"Stanovení hloubky průsaku tlakové vody","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie głębokości penetracji wody pod ciśnieniem","reference":"ČSN EN 12390-8","norm_bases":["ČSN EN 12390-8"],"lab_section":"3. Trutnov","lab_section_en":"3. Trutnov","lab_section_zh":"3. 特鲁特诺夫","lab_section_cs":"3. Trutnov","lab_address":"Kalná Voda 77, 542 23 Mladé Buky","regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Beton stwardniały Oznaczanie głębokości penetracji wody pod ciśnieniem Ztvrdlý beton Stanovení hloubky průsaku tlakové vody ČSN EN 12390-8 Beton stwardnialy Oznaczanie glebokosci penetracji wody pod cisnieniem Ztvrdly beton Stanoveni hloubky prusaku tlakove vody CSN EN 12390-8","search_en":"Hardened concrete Determination of depth of penetration of water under pressure ČSN EN 12390-8","search_zh":"硬化混凝土 压力水渗透深度测定 ČSN EN 12390-8","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":61,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"26056218fff381cddfd99c5c","lab_id":"69ad52a4de79e566650fd2da","country":"CZ","accr_number":"1195","accr_body":"ČIA","row_label":"15","test_object":"Beton stwardniały","test_object_en":"Hardened concrete","test_object_zh":"硬化混凝土","test_object_cs":"Ztvrdlý beton","methodology":"Oznaczanie głębokości penetracji wody pod ciśnieniem","methodology_en":"Determination of depth of penetration of water under pressure","methodology_zh":"压力水渗透深度测定","methodology_cs":"Stanovení hloubky průsaku tlakové vody","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie głębokości penetracji wody pod ciśnieniem","reference":"ČSN EN 12390-8","norm_bases":["ČSN EN 12390-8"],"lab_section":"4. Jindřichův Hradec","lab_section_en":"4. Jindřichův Hradec","lab_section_zh":"4. 因德日赫城","lab_section_cs":"4. Jindřichův Hradec","lab_address":"Jarošovská 2217/II, 377 01 Jindřichův Hradec","regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Beton stwardniały Oznaczanie głębokości penetracji wody pod ciśnieniem Ztvrdlý beton Stanovení hloubky průsaku tlakové vody ČSN EN 12390-8 Beton stwardnialy Oznaczanie glebokosci penetracji wody pod cisnieniem Ztvrdly beton Stanoveni hloubky prusaku tlakove vody CSN EN 12390-8","search_en":"Hardened concrete Determination of depth of penetration of water under pressure ČSN EN 12390-8","search_zh":"硬化混凝土 压力水渗透深度测定 ČSN EN 12390-8","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":62,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"b56439e16e6e5945f05cee9e","lab_id":"69ad52a4de79e566650fd2da","country":"CZ","accr_number":"1195","accr_body":"ČIA","row_label":"15","test_object":"Beton stwardniały","test_object_en":"Hardened concrete","test_object_zh":"硬化混凝土","test_object_cs":"Ztvrdlý beton","methodology":"Oznaczanie głębokości penetracji wody pod ciśnieniem","methodology_en":"Determination of depth of penetration of water under pressure","methodology_zh":"压力水渗透深度测定","methodology_cs":"Stanovení hloubky průsaku tlakové vody","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie głębokości penetracji wody pod ciśnieniem","reference":"ČSN EN 12390-8","norm_bases":["ČSN EN 12390-8"],"lab_section":"5. Klatovy","lab_section_en":"5. Klatovy","lab_section_zh":"5. 克拉托维","lab_section_cs":"5. Klatovy","lab_address":"Čertovka 890/2, 339 01 Klatovy","regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Beton stwardniały Oznaczanie głębokości penetracji wody pod ciśnieniem Ztvrdlý beton Stanovení hloubky průsaku tlakové vody ČSN EN 12390-8 Beton stwardnialy Oznaczanie glebokosci penetracji wody pod cisnieniem Ztvrdly beton Stanoveni hloubky prusaku tlakove vody CSN EN 12390-8","search_en":"Hardened concrete Determination of depth of penetration of water under pressure ČSN EN 12390-8","search_zh":"硬化混凝土 压力水渗透深度测定 ČSN EN 12390-8","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":63,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"a9ba98d2b633423a9337bd53","lab_id":"69ad52a4de79e566650fd2da","country":"CZ","accr_number":"1195","accr_body":"ČIA","row_label":"15","test_object":"Beton stwardniały","test_object_en":"Hardened concrete","test_object_zh":"硬化混凝土","test_object_cs":"Ztvrdlý beton","methodology":"Oznaczanie głębokości penetracji wody pod ciśnieniem","methodology_en":"Determination of depth of penetration of water under pressure","methodology_zh":"压力水渗透深度测定","methodology_cs":"Stanovení hloubky průsaku tlakové vody","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie głębokości penetracji wody pod ciśnieniem","reference":"ČSN EN 12390-8","norm_bases":["ČSN EN 12390-8"],"lab_section":"6. Cheb","lab_section_en":"6. Cheb","lab_section_zh":"6. 海布","lab_section_cs":"6. Cheb","lab_address":"Karlovarská 40, 350 02 Cheb","regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Beton stwardniały Oznaczanie głębokości penetracji wody pod ciśnieniem Ztvrdlý beton Stanovení hloubky průsaku tlakové vody ČSN EN 12390-8 Beton stwardnialy Oznaczanie glebokosci penetracji wody pod cisnieniem Ztvrdly beton Stanoveni hloubky prusaku tlakove vody CSN EN 12390-8","search_en":"Hardened concrete Determination of depth of penetration of water under pressure ČSN EN 12390-8","search_zh":"硬化混凝土 压力水渗透深度测定 ČSN EN 12390-8","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":64,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"8ad0c34c326d9152402c25d0","lab_id":"69ad52a4de79e566650fd2da","country":"CZ","accr_number":"1195","accr_body":"ČIA","row_label":"16","test_object":"Beton stwardniały","test_object_en":"Hardened concrete","test_object_zh":"硬化混凝土","test_object_cs":"Ztvrdlý beton","methodology":"Oznaczanie odporności powierzchni betonu na działanie wody i chemicznych środków odladzających","methodology_en":"Determination of resistance of concrete surface to water and chemical de-icing agents","methodology_zh":"混凝土表面抗水和化学除冰剂性能测定","methodology_cs":"Stanovení odolnosti povrchu betonu proti působení vody a chemických rozmrazovacích látek","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie odporności powierzchni betonu na działanie wody i chemicznych środków odladzających","reference":"ČSN 73 1326, mimo čl. 24 až 29","norm_bases":["ČSN 73 1326, mimo čl. 24 až 29"],"lab_section":"1. Beroun","lab_section_en":"1. Beroun","lab_section_zh":"1. 贝龙","lab_section_cs":"1. Beroun","lab_address":"Areál cementárny, Beroun 660, 266 01 Beroun","regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Beton stwardniały Oznaczanie odporności powierzchni betonu na działanie wody i chemicznych środków odladzających Ztvrdlý beton Stanovení odolnosti povrchu betonu proti působení vody a chemických rozmrazovacích látek ČSN 73 1326, mimo čl. 24 až 29 Beton stwardnialy Oznaczanie odpornosci powierzchni betonu na dzialanie wody i chemicznych srodkow odladzajacych Ztvrdly beton Stanoveni odolnosti povrchu betonu proti pusobeni vody a chemickych rozmrazovacich latek CSN 73 1326, mimo cl. 24 az 29","search_en":"Hardened concrete Determination of resistance of concrete surface to water and chemical de-icing agents ČSN 73 1326, mimo čl. 24 až 29","search_zh":"硬化混凝土 混凝土表面抗水和化学除冰剂性能测定 ČSN 73 1326, mimo čl. 24 až 29","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":65,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"a4379efbfcf5247949345df3","lab_id":"69ad52a4de79e566650fd2da","country":"CZ","accr_number":"1195","accr_body":"ČIA","row_label":"16","test_object":"Beton stwardniały","test_object_en":"Hardened concrete","test_object_zh":"硬化混凝土","test_object_cs":"Ztvrdlý beton","methodology":"Oznaczanie odporności powierzchni betonu na działanie wody i chemicznych środków odladzających","methodology_en":"Determination of resistance of concrete surface to water and chemical de-icing agents","methodology_zh":"混凝土表面抗水和化学除冰剂性能测定","methodology_cs":"Stanovení odolnosti povrchu betonu proti působení vody a chemických rozmrazovacích látek","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie odporności powierzchni betonu na działanie wody i chemicznych środków odladzających","reference":"ČSN 73 1326, mimo čl. 24 až 29","norm_bases":["ČSN 73 1326, mimo čl. 24 až 29"],"lab_section":"2. Most","lab_section_en":"2. Most","lab_section_zh":"2. 莫斯特","lab_section_cs":"2. Most","lab_address":"Areál MAPECO Most, a.s., 434 01 Most – Čepirohy","regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Beton stwardniały Oznaczanie odporności powierzchni betonu na działanie wody i chemicznych środków odladzających Ztvrdlý beton Stanovení odolnosti povrchu betonu proti působení vody a chemických rozmrazovacích látek ČSN 73 1326, mimo čl. 24 až 29 Beton stwardnialy Oznaczanie odpornosci powierzchni betonu na dzialanie wody i chemicznych srodkow odladzajacych Ztvrdly beton Stanoveni odolnosti povrchu betonu proti pusobeni vody a chemickych rozmrazovacich latek CSN 73 1326, mimo cl. 24 az 29","search_en":"Hardened concrete Determination of resistance of concrete surface to water and chemical de-icing agents ČSN 73 1326, mimo čl. 24 až 29","search_zh":"硬化混凝土 混凝土表面抗水和化学除冰剂性能测定 ČSN 73 1326, mimo čl. 24 až 29","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":66,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"440493910e0861c4fa3dec94","lab_id":"69ad52a4de79e566650fd2da","country":"CZ","accr_number":"1195","accr_body":"ČIA","row_label":"16","test_object":"Beton stwardniały","test_object_en":"Hardened concrete","test_object_zh":"硬化混凝土","test_object_cs":"Ztvrdlý beton","methodology":"Oznaczanie odporności powierzchni betonu na działanie wody i chemicznych środków odladzających","methodology_en":"Determination of resistance of concrete surface to water and chemical de-icing agents","methodology_zh":"混凝土表面抗水和化学除冰剂性能测定","methodology_cs":"Stanovení odolnosti povrchu betonu proti působení vody a chemických rozmrazovacích látek","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie odporności powierzchni betonu na działanie wody i chemicznych środków odladzających","reference":"ČSN 73 1326, mimo čl. 24 až 29","norm_bases":["ČSN 73 1326, mimo čl. 24 až 29"],"lab_section":"4. Jindřichův Hradec","lab_section_en":"4. Jindřichův Hradec","lab_section_zh":"4. 因德日赫城","lab_section_cs":"4. Jindřichův Hradec","lab_address":"Jarošovská 2217/II, 377 01 Jindřichův Hradec","regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Beton stwardniały Oznaczanie odporności powierzchni betonu na działanie wody i chemicznych środków odladzających Ztvrdlý beton Stanovení odolnosti povrchu betonu proti působení vody a chemických rozmrazovacích látek ČSN 73 1326, mimo čl. 24 až 29 Beton stwardnialy Oznaczanie odpornosci powierzchni betonu na dzialanie wody i chemicznych srodkow odladzajacych Ztvrdly beton Stanoveni odolnosti povrchu betonu proti pusobeni vody a chemickych rozmrazovacich latek CSN 73 1326, mimo cl. 24 az 29","search_en":"Hardened concrete Determination of resistance of concrete surface to water and chemical de-icing agents ČSN 73 1326, mimo čl. 24 až 29","search_zh":"硬化混凝土 混凝土表面抗水和化学除冰剂性能测定 ČSN 73 1326, mimo čl. 24 až 29","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":67,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"45cd12747aca1cb6fe279901","lab_id":"69ad52a4de79e566650fd2da","country":"CZ","accr_number":"1195","accr_body":"ČIA","row_label":"17","test_object":"Beton stwardniały","test_object_en":"Hardened concrete","test_object_zh":"硬化混凝土","test_object_cs":"Ztvrdlý beton","methodology":"Oznaczanie charakterystyki porów powietrznych","methodology_en":"Determination of air void characteristics","methodology_zh":"气孔特征测定","methodology_cs":"Stanovení charakteristiky vzduchových pórů","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie charakterystyki porów powietrznych","reference":"ČSN EN 480-11","norm_bases":["ČSN EN 480-11"],"lab_section":"2. Most","lab_section_en":"2. Most","lab_section_zh":"2. 莫斯特","lab_section_cs":"2. Most","lab_address":"Areál MAPECO Most, a.s., 434 01 Most – Čepirohy","regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Beton stwardniały Oznaczanie charakterystyki porów powietrznych Ztvrdlý beton Stanovení charakteristiky vzduchových pórů ČSN EN 480-11 Beton stwardnialy Oznaczanie charakterystyki porow powietrznych Ztvrdly beton Stanoveni charakteristiky vzduchovych poru CSN EN 480-11","search_en":"Hardened concrete Determination of air void characteristics ČSN EN 480-11","search_zh":"硬化混凝土 气孔特征测定 ČSN EN 480-11","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":68,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"4eb3d6ea0e9aabbf8c13ce03","lab_id":"69ad52a4de79e566650fd2da","country":"CZ","accr_number":"1195","accr_body":"ČIA","row_label":"18","test_object":"Beton stwardniały","test_object_en":"Hardened concrete","test_object_zh":"硬化混凝土","test_object_cs":"Ztvrdlý beton","methodology":"Oznaczanie statycznego modułu sprężystości przy ściskaniu","methodology_en":"Determination of static modulus of elasticity in compression","methodology_zh":"静力受压弹性模量测定","methodology_cs":"Stanovení statického modulu pružnosti v tlaku","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie statycznego modułu sprężystości przy ściskaniu","reference":"ČSN ISO 1920-10","norm_bases":["ČSN ISO 1920-10"],"lab_section":"2. Most","lab_section_en":"2. Most","lab_section_zh":"2. 莫斯特","lab_section_cs":"2. Most","lab_address":"Areál MAPECO Most, a.s., 434 01 Most – Čepirohy","regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Beton stwardniały Oznaczanie statycznego modułu sprężystości przy ściskaniu Ztvrdlý beton Stanovení statického modulu pružnosti v tlaku ČSN ISO 1920-10 Beton stwardnialy Oznaczanie statycznego modulu sprezystosci przy sciskaniu Ztvrdly beton Stanoveni statickeho modulu pruznosti v tlaku CSN ISO 1920-10","search_en":"Hardened concrete Determination of static modulus of elasticity in compression ČSN ISO 1920-10","search_zh":"硬化混凝土 静力受压弹性模量测定 ČSN ISO 1920-10","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":69,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"8b0f2ee4f34cf58e87cec356","lab_id":"69ad52a4de79e566650fd2da","country":"CZ","accr_number":"1195","accr_body":"ČIA","row_label":"19","test_object":"Materiały jastrychowe","test_object_en":"Screed materials","test_object_zh":"找平层材料","test_object_cs":"Potěrové materiály","methodology":"Oznaczanie wytrzymałości na zginanie i ściskanie","methodology_en":"Determination of flexural and compressive strength","methodology_zh":"抗折和抗压强度测定","methodology_cs":"Stanovení pevnosti v tahu za ohybu a v tlaku","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie wytrzymałości na zginanie i ściskanie","reference":"ČSN EN 13892-2","norm_bases":["ČSN EN 13892-2"],"lab_section":"1. Beroun","lab_section_en":"1. Beroun","lab_section_zh":"1. 贝龙","lab_section_cs":"1. Beroun","lab_address":"Areál cementárny, Beroun 660, 266 01 Beroun","regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Materiały jastrychowe Oznaczanie wytrzymałości na zginanie i ściskanie Potěrové materiály Stanovení pevnosti v tahu za ohybu a v tlaku ČSN EN 13892-2 Materialy jastrychowe Oznaczanie wytrzymalosci na zginanie i sciskanie Poterove materialy Stanoveni pevnosti v tahu za ohybu a v tlaku CSN EN 13892-2","search_en":"Screed materials Determination of flexural and compressive strength ČSN EN 13892-2","search_zh":"找平层材料 抗折和抗压强度测定 ČSN EN 13892-2","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":70,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"df751340ba6fc893127bdf7c","lab_id":"69ad52a4de79e566650fd2da","country":"CZ","accr_number":"1195","accr_body":"ČIA","row_label":"20","test_object":"Zaprawa","test_object_en":"Mortar","test_object_zh":"砂浆","test_object_cs":"Malta","methodology":"Oznaczanie wytrzymałości na zginanie i ściskanie","methodology_en":"Determination of flexural and compressive strength","methodology_zh":"抗折和抗压强度测定","methodology_cs":"Stanovení pevnosti v tahu za ohybu a v tlaku","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie wytrzymałości na zginanie i ściskanie","reference":"ČSN EN 1015-11","norm_bases":["ČSN EN 1015-11"],"lab_section":"1. Beroun","lab_section_en":"1. Beroun","lab_section_zh":"1. 贝龙","lab_section_cs":"1. Beroun","lab_address":"Areál cementárny, Beroun 660, 266 01 Beroun","regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Zaprawa Oznaczanie wytrzymałości na zginanie i ściskanie Malta Stanovení pevnosti v tahu za ohybu a v tlaku ČSN EN 1015-11 Zaprawa Oznaczanie wytrzymalosci na zginanie i sciskanie Malta Stanoveni pevnosti v tahu za ohybu a v tlaku CSN EN 1015-11","search_en":"Mortar Determination of flexural and compressive strength ČSN EN 1015-11","search_zh":"砂浆 抗折和抗压强度测定 ČSN EN 1015-11","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":71,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"2b032f744c02e4e8372efb30","lab_id":"69ad52a4de79e566650fd2da","country":"CZ","accr_number":"1195","accr_body":"ČIA","row_label":"21","test_object":"Cement","test_object_en":"Cement","test_object_zh":"水泥","test_object_cs":"Cement","methodology":"Oznaczanie wytrzymałości na zginanie i ściskanie","methodology_en":"Determination of flexural and compressive strength","methodology_zh":"抗折和抗压强度测定","methodology_cs":"Stanovení pevnosti v tahu za ohybu a v tlaku","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie wytrzymałości na zginanie i ściskanie","reference":"ČSN EN 196-1","norm_bases":["ČSN EN 196-1"],"lab_section":"1. Beroun","lab_section_en":"1. Beroun","lab_section_zh":"1. 贝龙","lab_section_cs":"1. Beroun","lab_address":"Areál cementárny, Beroun 660, 266 01 Beroun","regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Cement Oznaczanie wytrzymałości na zginanie i ściskanie Cement Stanovení pevnosti v tahu za ohybu a v tlaku ČSN EN 196-1 Cement Oznaczanie wytrzymalosci na zginanie i sciskanie Cement Stanoveni pevnosti v tahu za ohybu a v tlaku CSN EN 196-1","search_en":"Cement Determination of flexural and compressive strength ČSN EN 196-1","search_zh":"水泥 抗折和抗压强度测定 ČSN EN 196-1","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":72,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"c68d01d78171a95f93d9e985","lab_id":"69ad52a4de79e566650fd2da","country":"CZ","accr_number":"1195","accr_body":"ČIA","row_label":"22","test_object":"Beton stwardniały","test_object_en":"Hardened concrete","test_object_zh":"硬化混凝土","test_object_cs":"Ztvrdlý beton","methodology":"Oznaczanie twardości i wytrzymałości z niegwarantowaną dokładnością sklerometrem odbiciowym","methodology_en":"Determination of hardness and strength with non-guaranteed accuracy using a rebound hammer","methodology_zh":"回弹仪测定硬度和强度（精度不保证）","methodology_cs":"Stanovení tvrdosti a pevnosti s nezaručenou přesností odrazovým tvrdoměrem","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie twardości i wytrzymałości z niegwarantowaną dokładnością sklerometrem odbiciowym","reference":"ČSN EN 12504-2; ČSN 73 1373, čl. 6.2","norm_bases":["ČSN EN 12504-2","ČSN 73 1373, čl. 6.2"],"lab_section":"6. Cheb","lab_section_en":"6. Cheb","lab_section_zh":"6. 海布","lab_section_cs":"6. Cheb","lab_address":"Karlovarská 40, 350 02 Cheb","regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Beton stwardniały Oznaczanie twardości i wytrzymałości z niegwarantowaną dokładnością sklerometrem odbiciowym Ztvrdlý beton Stanovení tvrdosti a pevnosti s nezaručenou přesností odrazovým tvrdoměrem ČSN EN 12504-2; ČSN 73 1373, čl. 6.2 Beton stwardnialy Oznaczanie twardosci i wytrzymalosci z niegwarantowana dokladnoscia sklerometrem odbiciowym Ztvrdly beton Stanoveni tvrdosti a pevnosti s nezarucenou presnosti odrazovym tvrdomerem CSN EN 12504-2; CSN 73 1373, cl. 6.2","search_en":"Hardened concrete Determination of hardness and strength with non-guaranteed accuracy using a rebound hammer ČSN EN 12504-2; ČSN 73 1373, čl. 6.2","search_zh":"硬化混凝土 回弹仪测定硬度和强度（精度不保证） ČSN EN 12504-2; ČSN 73 1373, čl. 6.2","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":73,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"e64c4a9320bd0242332932e8","lab_id":"69ad52a4de79e566650fd2da","country":"CZ","accr_number":"1195","accr_body":"ČIA","row_label":"23","test_object":"Kruszywo","test_object_en":"Aggregates","test_object_zh":"集料","test_object_cs":"Kamenivo","methodology":"Oznaczanie odporności na zamrażanie i rozmrażanie","methodology_en":"Determination of resistance to freezing and thawing","methodology_zh":"抗冻融性测定","methodology_cs":"Stanovení odolnosti proti zmrazování a rozmrazování","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie odporności na zamrażanie i rozmrażanie","reference":"ČSN EN 1367-1","norm_bases":["ČSN EN 1367-1"],"lab_section":"2. Most","lab_section_en":"2. Most","lab_section_zh":"2. 莫斯特","lab_section_cs":"2. Most","lab_address":"Areál MAPECO Most, a.s., 434 01 Most – Čepirohy","regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Kruszywo Oznaczanie odporności na zamrażanie i rozmrażanie Kamenivo Stanovení odolnosti proti zmrazování a rozmrazování ČSN EN 1367-1 Kruszywo Oznaczanie odpornosci na zamrazanie i rozmrazanie Kamenivo Stanoveni odolnosti proti zmrazovani a rozmrazovani CSN EN 1367-1","search_en":"Aggregates Determination of resistance to freezing and thawing ČSN EN 1367-1","search_zh":"集料 抗冻融性测定 ČSN EN 1367-1","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":74,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"cc51b95d2e9ebfb5907b4454","lab_id":"69ad52a4de79e566650fd2da","country":"CZ","accr_number":"1195","accr_body":"ČIA","row_label":"24","test_object":"Mieszanka związana spoiwem hydraulicznym","test_object_en":"Hydraulically bound mixture","test_object_zh":"水硬性结合料稳定混合料","test_object_cs":"Směs stmelená hydraulickým pojivem","methodology":"Oznaczanie laboratoryjnej porównawczej gęstości objętościowej","methodology_en":"Determination of the laboratory reference density","methodology_zh":"实验室参考密度测定","methodology_cs":"Stanovení laboratorní srovnávací objemové hmotnosti","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie laboratoryjnej porównawczej gęstości objętościowej","reference":"ČSN EN 13286-2, mimo čl. 7.3, 7.6","norm_bases":["ČSN EN 13286-2, mimo čl. 7.3, 7.6"],"lab_section":"2. Most","lab_section_en":"2. Most","lab_section_zh":"2. 莫斯特","lab_section_cs":"2. Most","lab_address":"Areál MAPECO Most, a.s., 434 01 Most – Čepirohy","regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Mieszanka związana spoiwem hydraulicznym Oznaczanie laboratoryjnej porównawczej gęstości objętościowej Směs stmelená hydraulickým pojivem Stanovení laboratorní srovnávací objemové hmotnosti ČSN EN 13286-2, mimo čl. 7.3, 7.6 Mieszanka zwiazana spoiwem hydraulicznym Oznaczanie laboratoryjnej porownawczej gestosci objetosciowej Smes stmelena hydraulickym pojivem Stanoveni laboratorni srovnavaci objemove hmotnosti CSN EN 13286-2, mimo cl. 7.3, 7.6","search_en":"Hydraulically bound mixture Determination of the laboratory reference density ČSN EN 13286-2, mimo čl. 7.3, 7.6","search_zh":"水硬性结合料稳定混合料 实验室参考密度测定 ČSN EN 13286-2, mimo čl. 7.3, 7.6","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":75,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"d0fa3976f9ee14b247f869b3","lab_id":"69ad52a4de79e566650fd2da","country":"CZ","accr_number":"1195","accr_body":"ČIA","row_label":"25","test_object":"Mieszanka związana spoiwem hydraulicznym","test_object_en":"Hydraulically bound mixture","test_object_zh":"水硬性结合料稳定混合料","test_object_cs":"Směs stmelená hydraulickým pojivem","methodology":"Oznaczanie wytrzymałości na ściskanie","methodology_en":"Determination of compressive strength","methodology_zh":"抗压强度测定","methodology_cs":"Stanovení pevnosti v tlaku","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie wytrzymałości na ściskanie","reference":"ČSN EN 13286-41","norm_bases":["ČSN EN 13286-41"],"lab_section":"2. Most","lab_section_en":"2. Most","lab_section_zh":"2. 莫斯特","lab_section_cs":"2. Most","lab_address":"Areál MAPECO Most, a.s., 434 01 Most – Čepirohy","regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Mieszanka związana spoiwem hydraulicznym Oznaczanie wytrzymałości na ściskanie Směs stmelená hydraulickým pojivem Stanovení pevnosti v tlaku ČSN EN 13286-41 Mieszanka zwiazana spoiwem hydraulicznym Oznaczanie wytrzymalosci na sciskanie Smes stmelena hydraulickym pojivem Stanoveni pevnosti v tlaku CSN EN 13286-41","search_en":"Hydraulically bound mixture Determination of compressive strength ČSN EN 13286-41","search_zh":"水硬性结合料稳定混合料 抗压强度测定 ČSN EN 13286-41","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":76,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"615f9b1bd63652ccee57cbc3","lab_id":"69ad52a4de79e566650fd2da","country":"CZ","accr_number":"1195","accr_body":"ČIA","row_label":"26","test_object":"Mieszanka związana spoiwem hydraulicznym","test_object_en":"Hydraulically bound mixture","test_object_zh":"水硬性结合料稳定混合料","test_object_cs":"Směs stmelená hydraulickým pojivem","methodology":"Oznaczanie czasu urabialności","methodology_en":"Determination of workability period","methodology_zh":"可操作时间测定","methodology_cs":"Stanovení doby zpracovatelnosti","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie czasu urabialności","reference":"ČSN EN 13286-45, mimo čl. 6","norm_bases":["ČSN EN 13286-45, mimo čl. 6"],"lab_section":"2. Most","lab_section_en":"2. Most","lab_section_zh":"2. 莫斯特","lab_section_cs":"2. Most","lab_address":"Areál MAPECO Most, a.s., 434 01 Most – Čepirohy","regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Mieszanka związana spoiwem hydraulicznym Oznaczanie czasu urabialności Směs stmelená hydraulickým pojivem Stanovení doby zpracovatelnosti ČSN EN 13286-45, mimo čl. 6 Mieszanka zwiazana spoiwem hydraulicznym Oznaczanie czasu urabialnosci Smes stmelena hydraulickym pojivem Stanoveni doby zpracovatelnosti CSN EN 13286-45, mimo cl. 6","search_en":"Hydraulically bound mixture Determination of workability period ČSN EN 13286-45, mimo čl. 6","search_zh":"水硬性结合料稳定混合料 可操作时间测定 ČSN EN 13286-45, mimo čl. 6","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":77,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"bcea1b1d57dce9e0b45821f1","lab_id":"69ad52a4de79e566650fd2da","country":"CZ","accr_number":"1195","accr_body":"ČIA","row_label":"27","test_object":"Mieszanka związana spoiwem hydraulicznym","test_object_en":"Hydraulically bound mixture","test_object_zh":"水硬性结合料稳定混合料","test_object_cs":"Směs stmelená hydraulickým pojivem","methodology":"Oznaczanie odporności mieszanki na mróz i wodę","methodology_en":"Determination of frost and water resistance of the mixture","methodology_zh":"混合料抗冻和抗水性测定","methodology_cs":"Stanovení odolnosti směsi proti mrazu a vodě","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie odporności mieszanki na mróz i wodę","reference":"ČSN 73 6124-1, příl. A","norm_bases":["ČSN 73 6124-1, příl. A"],"lab_section":"2. Most","lab_section_en":"2. Most","lab_section_zh":"2. 莫斯特","lab_section_cs":"2. Most","lab_address":"Areál MAPECO Most, a.s., 434 01 Most – Čepirohy","regulatory_area":null,"regulatory_area_en":null,"regulatory_area_zh":null,"regulatory_area_cs":null,"flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Mieszanka związana spoiwem hydraulicznym Oznaczanie odporności mieszanki na mróz i wodę Směs stmelená hydraulickým pojivem Stanovení odolnosti směsi proti mrazu a vodě ČSN 73 6124-1, příl. A Mieszanka zwiazana spoiwem hydraulicznym Oznaczanie odpornosci mieszanki na mroz i wode Smes stmelena hydraulickym pojivem Stanoveni odolnosti smesi proti mrazu a vode CSN 73 6124-1, pril. A","search_en":"Hydraulically bound mixture Determination of frost and water resistance of the mixture ČSN 73 6124-1, příl. A","search_zh":"水硬性结合料稳定混合料 混合料抗冻和抗水性测定 ČSN 73 6124-1, příl. A","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":78,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"}],"has_pdf":true}