🇨🇿 NOVÁ HUŤ s.r.o. PL
Water & wastewaterMaterials & polymers
NOVÁ HUŤ s.r.o. is a laboratory accredited by ČIA under number 1178 (Ostrava, Czech Republic). Its accreditation scope covers 51 test methods in the following areas: Water & wastewater, Materials & polymers. Test objects include: Waste water, drinking and service water, surface water, service mak…, Metallurgical product, semiproduct, Metallurgical product, tubes, Waste water, drinking and service water, surface water, service mak….
At a glance
- Accreditation number: ČIA 1178
- Methods in scope: 51
- Types of test objects: 15
- City: Ostrava, Czech Republic
- Valid until: 19-05-2031
- Accreditation number
- 1178
- Accreditation body
- ČIA
- Address
- Vratimovská 689/117, Kunčice, 719 00 Ostrava
- City
- Ostrava, Czech Republic
- Division
- Laboratoria hutnicze i chemiczne
- Valid until
- 19-05-2031
What this laboratory tests (15)
- Waste water, drinking and service water, surface water, service make-up water — 17 methods
- Metallurgical product, semiproduct — 12 methods
- Metallurgical product, tubes — 5 methods
- Waste water, drinking and service water, surface water, service make-up water, hot water made from drinking water, hot water made from service water — 3 methods
- Drinking and service water, surface water, service make-up water, hot water made from drinking water, hot water made from service water — 2 methods
- Metallurgical product — 2 methods
- Waste water, drinking and service water, surface water, service make-up water, ground water — 2 methods
- Drinking and service water, hot water made from drinking water, hot water made from service water — 1 method
- Drinking water, hot water made of drinking water, service water, hot water made of service water — 1 method
- Metallurgical product, concrete reinforcing steel, thread bars — 1 method
- Steel — 1 method
- Surface water, service make-up water — 1 method
- Waste water — 1 method
- Waste water, service make-up water — 1 method
- Waste water, service make-up water, surface water — 1 method
Laboratory sections (4)
- Water Management Laboratory — 28 methods
- Mechanical Testing Laboratory — 13 methods
- Structural Analysis Laboratory — 7 methods
- Spectrometric Laboratory — 3 methods
Laboratory locations
- Laboratorium badań mechanicznych — Vratimovská 689/117
- Laboratorium analiz strukturalnych — Vratimovská 689/117
- Laboratorium spektrometryczne — Vratimovská 689/117
- Laboratorium gospodarki wodnej — Vratimovská 689/117
Certificate information
- Certificate date
- 19.05.2026
Accreditation scope — test methods (51)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Mechanical Testing Laboratory | |||||
| 1 | Metallurgical product, semiproduct | Tensile test at room temperature Regulated area: Tests |
PP-L/Z/1 (ČSN EN ISO 6892-1; ASTM E8/E8M) | ||
| 2 | Metallurgical product, semiproduct | Impact bend test Regulated area: Tests |
PP-L/Z/2 (ČSN EN ISO 148-1; ASTM E23) | ||
| 3 | Metallurgical product, semiproduct | Rockwell hardness test Regulated area: Tests |
PP-L/Z/3 (ČSN EN ISO 6508-1; ASTM E18) | ||
| 4 | Metallurgical product, semiproduct | Vickers hardness test Regulated area: Tests |
PP-L/Z/4 (ČSN EN ISO 6507-1) | ||
| 5 | Metallurgical product, semiproduct | Brinell hardness test Regulated area: Tests |
PP-L/Z/5 (ČSN EN ISO 6506-1; ASTM E10) | ||
| 6 | Metallurgical product, tubes | Technological bend test Regulated area: Tests |
PP-L/Z/6 (ČSN EN ISO 8491; ASTM A106/A106M) | ||
| 7 | Metallurgical product, tubes | Technological widening test Regulated area: Tests |
PP-L/Z/6 (ČSN EN ISO 8493) | ||
| 8 | Metallurgical product, tubes | Technological flattening test Regulated area: Tests |
PP-L/Z/6 (ČSN EN ISO 8492) | ||
| 9 | Metallurgical product, tubes | Technological ring-expanding test Regulated area: Tests |
PP-L/Z/6 (ČSN EN ISO 8495) | ||
| 10 | Metallurgical product, tubes | Technological ring tensile test Regulated area: Tests |
PP-L/Z/6 (ČSN EN ISO 8496) | ||
| 11 | Metallurgical product | Bend test Regulated area: Tests |
PP-L/Z/11 (ČSN EN ISO 7438; ČSN EN ISO 5173) | ||
| 12 | Metallurgical product, semiproduct | Fatigue test of metals at rotation Regulated area: Tests |
PP-L/Z/12 (ČSN 42 0363) | ||
| 13 | Metallurgical product, concrete reinforcing steel, thread bars | Measurement of the geometry of ribs and match plane by optical method Regulated area: Tests |
PP-L/Z/17 (ČSN EN ISO 15630-1; ČSN EN ISO 15630-3) | ||
| Structural Analysis Laboratory | |||||
| 14 | Metallurgical product, semiproduct | Macroscopic tests Regulated area: Tests |
PP-L/M/10 (ČSN 42 0467; ISO 4969; ČSN EN ISO 17 639) | ||
| 15 | Metallurgical product, semiproduct | Metallographic determination of non-metallic inclusions in steel Regulated area: Tests |
PP-L/M/12 (ČSN ISO 4967; ASTM E 45; DIN 50 602:1985) | ||
| 16 | Metallurgical product, semiproduct | Micrographic determination of grain size of steels and non-ferrous metals Regulated area: Tests |
PP-L/M/13 (ČSN 42 0462; ČSN EN ISO 643; ASTM E 112) | ||
| 17 | Metallurgical product | Metallographic evaluation of wrought metallurgical products Regulated area: Tests |
PP-L/M/14 (ČSN 42 0469) | ||
| 18 | Metallurgical product, semiproduct | Determination of depth of decarburization by metallographic method Regulated area: Tests |
PP-L/M/15 (ČSN EN ISO 3887) | ||
| 19 | Metallurgical product, semiproduct | Quantitative metallographic tests using image analysis Regulated area: Tests |
PP-L/M/16 (ASTM E 45; DIN 50602:1985; ČSN ISO 4967) | ||
| 20 | Metallurgical product, semiproduct | Metallographic evaluation of cast iron structure Regulated area: Tests |
PP-L/M/17 (ČSN EN ISO 945-1; ČSN 42 0461:1975) | ||
| Spectrometric Laboratory | |||||
| 21 | Waste water, drinking and service water, surface water, service make-up water, ground water | Determination of elements by ICP-OES method Iron (Fe) Zinc (Zn) Manganese (Mn) Copper (Cu) Chromium (Cr) Nickel (Ni) Cadmium (Cd) Lead (Pb) Regulated area: Tests |
SOP-L/AS/1-4-1 (ČSN EN ISO 11 885) | ||
| 22 | Waste water, drinking and service water, surface water, service make-up water, ground water | Determination of Hg by AMA-254 analyzer Regulated area: Tests |
SOP-L/AS/2-1-1 (ČSN 75 7440) | ||
| 23 | Steel | Determination of elements by OES method Boron (B) Carbon (C) Soluble aluminium (Al soluble) Total aluminium (Al total) Silicon (Si) Phosphorus (P) Sulphur (S) Calcium (Ca) Titanium (Ti) Vanadium (V) Chromium (Cr) Manganese (Mn) Cobalt (Co) Nickel (Ni) Copper (Cu) Arsenic (As) Molybdenum (Mo) Tin (Sn) Niobium (Nb) Nitrogen (N) Regulated area: Tests |
SOP-L/S/4 (ASTM E 415-17) | ||
| Water Management Laboratory | |||||
| 24 | Waste water, drinking and service water, surface water, service make-up water | Determination of hydrocarbons C10 – C40 by GC-FID method after extraction with a solvent Regulated area: Tests |
SOP-L/AM/9 (ČSN EN ISO 9377-2) | ||
| 25 | Waste water, drinking and service water, surface water, service make-up water, hot water made from drinking water, hot water made from service water | Determination of temperature Regulated area: Tests |
SOP-L/AV1 (ČSN 75 7342) | ||
| 26 | Waste water, drinking and service water, surface water, service make-up water, hot water made from drinking water, hot water made from service water | Determination of pH by potentiometry Regulated area: Tests |
SOP-L/AV2 (ČSN ISO 10 523) | ||
| 27 | Waste water, drinking and service water, surface water, service make-up water | Determination of conductivity Regulated area: Tests |
SOP-L/AV3 (ČSN EN 27 888) | ||
| 28 | Drinking and service water, surface water, service make-up water, hot water made from drinking water, hot water made from service water | Determination of colour by spectrophotometry Regulated area: Tests |
SOP-L/AV4 (ČSN EN ISO 7887) | ||
| 29 | Drinking and service water, surface water, service make-up water, hot water made from drinking water, hot water made from service water | Determination of turbidity by nephelometry Regulated area: Tests |
SOP-L/AV5 (ČSN EN ISO 7027) | ||
| 30 | Drinking and service water, hot water made from drinking water, hot water made from service water | Determination of free and total chlorine by spectrophotometry Regulated area: Tests |
SOP-L/AV6 (ČSN ISO 7393-2) | ||
| 31 | Waste water, drinking and service water, surface water, service make-up water | Determination of dissolved solids and DIS by gravimetry Regulated area: Tests |
SOP-L/AV7 (ČSN 75 7346; ČSN 75 7347) | ||
| 32 | Waste water, drinking and service water, surface water, service make-up water | Determination of suspended solids by gravimetry Regulated area: Tests |
SOP-L/AV8 (ČSN EN 872) | ||
| 33 | Waste water, drinking and service water, surface water, service make-up water, hot water made from drinking water, hot water made from service water | Determination of chemical oxygen demand with permanganate (CODMn) by titration Regulated area: Tests |
SOP-L/AV9 (ČSN EN ISO 8467) | ||
| 34 | Waste water, drinking and service water, surface water, service make-up water | Determination of chemical oxygen demand with dichromate (CODCr) by titration Regulated area: Tests |
SOP-L/AV10 (ČSN ISO 6060) | ||
| 35 | Waste water, drinking and service water, surface water, service make-up water | Determination of biochemical oxygen demand (BOD5) by titration Regulated area: Tests |
SOP-L/AV11 (ČSN EN ISO 5815-1) | ||
| 36 | Waste water, drinking and service water, surface water, service make-up water | Determination of chlorides by titration Regulated area: Tests |
SOP-L/AV12 (ČSN ISO 9297) | ||
| 37 | Waste water, drinking and service water, surface water, service make-up water | Determination of sulphate by titration Regulated area: Tests |
SOP-L/AV13 (ČSN 75 7477) | ||
| 38 | Waste water, drinking and service water, surface water, service make-up water | Determination of nitrite by spectrophotometry and nitrite nitrogen by calculation from measured values Regulated area: Tests |
SOP-L/AV14 (ČSN EN 26777) | ||
| 39 | Waste water, drinking and service water, surface water, service make-up water | Determination of nitrate by spectrophotometry, nitrate and inorganic nitrogen by calculation from measured values Regulated area: Tests |
SOP-L/AV15 (ČSN ISO 7890-3) | ||
| 40 | Waste water, drinking and service water, surface water, service make-up water | Determination of total phosphorus by spectrophotometry Regulated area: Tests |
SOP-L/AV16 (ČSN EN ISO 6878) | ||
| 41 | Waste water, service make-up water | Determination of total cyanide by spectrophotometry Regulated area: Tests |
SOP-L/AV17 (ČSN 75 7415) | ||
| 42 | Waste water, drinking and service water, surface water, service make-up water | Determination of ammonium by titration after distillation and ammonia nitrogen by calculation from measured values Regulated area: Tests |
SOP-L/AV18 (ČSN ISO 5664) | ||
| 43 | Waste water, drinking and service water, surface water, service make-up water | Determination of univalent phenols by spectrophotometry Regulated area: Tests |
SOP-L/AV19 (ČSN ISO 6439) | ||
| 44 | Waste water, drinking and service water, surface water, service make-up water | Determination of ammonium by spectrophotometry and ammonia nitrogen by calculation from measured values Regulated area: Tests |
SOP-L/AV20 (ČSN ISO 7150–1) | ||
| 45 | Waste water, service make-up water, surface water | Determination of adsorbable organically bound halogens (AOX) by coulometry Regulated area: Tests |
SOP-L/AV21 (ČSN EN ISO 9562) | ||
| 46 | Waste water, drinking and service water, surface water, service make-up water | Determination of total Fe by photometry Regulated area: Tests |
SOP-L/AV23 (ČSN ISO 6332) | ||
| 47 | Waste water, drinking and service water, surface water, service make-up water | Determination of Ca by titration Regulated area: Tests |
SOP-L/AV27 (ČSN ISO 6058) | ||
| 48 | Waste water, drinking and service water, surface water, service make-up water | Determination of hardness (sum of Ca and Mg) by titration Regulated area: Tests |
SOP-L/AV28 (ČSN ISO 6059) | ||
| 49 | Drinking water, hot water made of drinking water, service water, hot water made of service water | Drinking, service and hot water, manual sampling Regulated area: Sampling |
SOP-L/AV36 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-5; ČSN ISO 5667-14) | ||
| 50 | Waste water | Sampling of waste water, manual sampling and by an automatic sampler Regulated area: Sampling |
SOP-L/AV37 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-10; ČSN ISO 5667-14) | ||
| 51 | Surface water, service make-up water | Water sampling, manual sampling Regulated area: Sampling |
SOP-L/AV38 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-4; ČSN ISO 5667-6; ČSN ISO 5667-14) | ||
Reference standards (117)
ASTM A106/A106M
ASTM E 112
ASTM E 415-17
ASTM E 45
ASTM E10
ASTM E18
ASTM E23
ASTM E8/E8M
DIN 50 602:1985
DIN 50602:1985
ISO 4969
PP-L/M/10
PP-L/M/12
PP-L/M/13
PP-L/M/14
PP-L/M/15
PP-L/M/16
PP-L/M/17
PP-L/Z/1
PP-L/Z/11
PP-L/Z/12
PP-L/Z/17
PP-L/Z/2
PP-L/Z/3
PP-L/Z/4
PP-L/Z/5
PP-L/Z/6
SOP-L/AM/9
SOP-L/AS/1-4-1
SOP-L/AS/2-1-1
SOP-L/AV1
SOP-L/AV10
SOP-L/AV11
SOP-L/AV12
SOP-L/AV13
SOP-L/AV14
SOP-L/AV15
SOP-L/AV16
SOP-L/AV17
SOP-L/AV18
SOP-L/AV19
SOP-L/AV2
SOP-L/AV20
SOP-L/AV21
SOP-L/AV23
SOP-L/AV27
SOP-L/AV28
SOP-L/AV3
SOP-L/AV36
SOP-L/AV37
SOP-L/AV38
SOP-L/AV4
SOP-L/AV5
SOP-L/AV6
SOP-L/AV7
SOP-L/AV8
SOP-L/AV9
SOP-L/S/4
ČSN 42 0363
ČSN 42 0461:1975
ČSN 42 0462
ČSN 42 0467
ČSN 42 0469
ČSN 75 7342
ČSN 75 7346
ČSN 75 7347
ČSN 75 7415
ČSN 75 7440
ČSN 75 7477
ČSN EN 26777
ČSN EN 27 888
ČSN EN 872
ČSN EN ISO 11 885
ČSN EN ISO 148-1
ČSN EN ISO 15630-1
ČSN EN ISO 15630-3
ČSN EN ISO 17 639
ČSN EN ISO 3887
ČSN EN ISO 5173
ČSN EN ISO 5667-1
ČSN EN ISO 5667-3
ČSN EN ISO 5815-1
ČSN EN ISO 643
ČSN EN ISO 6506-1
ČSN EN ISO 6507-1
ČSN EN ISO 6508-1
ČSN EN ISO 6878
ČSN EN ISO 6892-1
ČSN EN ISO 7027
ČSN EN ISO 7438
ČSN EN ISO 7887
ČSN EN ISO 8467
ČSN EN ISO 8491
ČSN EN ISO 8492
ČSN EN ISO 8493
ČSN EN ISO 8495
ČSN EN ISO 8496
ČSN EN ISO 9377-2
ČSN EN ISO 945-1
ČSN EN ISO 9562
ČSN ISO 10 523
ČSN ISO 4967
ČSN ISO 5664
ČSN ISO 5667-10
ČSN ISO 5667-14
ČSN ISO 5667-4
ČSN ISO 5667-5
ČSN ISO 5667-6
ČSN ISO 6058
ČSN ISO 6059
ČSN ISO 6060
ČSN ISO 6332
ČSN ISO 6439
ČSN ISO 7150–1
ČSN ISO 7393-2
ČSN ISO 7890-3
ČSN ISO 9297