🇨🇿 TESTALARM PRAHA spol. s r.o. PL
Electronics & EMC
TESTALARM PRAHA spol. s r.o. is a laboratory accredited by ČIA under number 1172 (Praha 4 - Modřany, Czech Republic). Its accreditation scope covers 37 test methods in the following areas: Electronics & EMC. Test objects include: I&HAS – all components, I&HAS – all components, ZVB (high security locks), I&HAS – ALDDR detectors, I&HAS – building communication systems.
At a glance
- Accreditation number: ČIA 1172
- Methods in scope: 37
- Types of test objects: 19
- City: Praha 4 - Modřany, Czech Republic
- Valid until: 13-01-2031
- Accreditation number
- 1172
- Accreditation body
- ČIA
- Address
- Popovova 1788/10, 143 00 Praha 4 - Modřany
- City
- Praha 4 - Modřany, Czech Republic
- Division
- Laboratorium Badawcze
- Valid until
- 13-01-2031
What this laboratory tests (19)
- I&HAS – all components — 17 methods
- I&HAS – all components, ZVB (high security locks) — 3 methods
- I&HAS – ALDDR detectors — 1 method
- I&HAS – building communication systems — 1 method
- I&HAS – CCTV — 1 method
- I&HAS – control and indicating equipment — 1 method
- I&HAS – directional detectors (AIBD, MW, dual) — 1 method
- I&HAS – electronic access control systems and release locks — 1 method
- I&HAS – glass break detectors — 1 method
- I&HAS – opening contacts and opening status detectors — 1 method
- I&HAS – passive infrared, microwave and combined detectors — 1 method
- I&HAS – perimeter systems — 1 method
- I&HAS – power supply — 1 method
- I&HAS – shock (vibration) detectors — 1 method
- I&HAS – social alarm systems, installation accessories (junction boxes, covers) — 1 method
- and 4 more
Certificate information
- Certificate date
- 13.01.2026
Accreditation scope — test methods (37)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Test methods | |||||
| 1 | I&HAS – control and indicating equipment | Test of properties and parameters Regulated area: Tests |
ČSN EN 50131-1 ed. 2; ČSN EN 50131-3; ČSN CLC/TS 50131-12; ČSN CLC/TS 50131-9 | ||
| 2 | I&HAS – passive infrared, microwave and combined detectors | Test of properties and parameters Regulated area: Tests |
EN 50131-2-2:2021, kap. 6; ČSN EN 50131-2-2 ed. 3, kap. 6; ČSN EN 50131-2-2 ed. 2:2018, kap. 6; ČSN EN 50131-2-2:2008, kap. 6; EN 50131-2-3:2021, kap. 6; ČSN EN 50131-2-3:2009, kap. 6; ČSN EN 50131-2-3 ed. 2, kap. 6; EN 50131-2-4:2020, kap. 6; ČSN EN 50131-2-4 ed. 2, kap. 6; ČSN EN 50131-2-4:2009, kap. 6; ČSN EN 50131-1 ed. 2 | ||
| 3 | I&HAS – opening contacts and opening status detectors | Test of properties and parameters Regulated area: Tests |
ČSN EN 50131-2-6, kap. 6; ČSN EN 50131-1 ed. 2; ČSN EN 50131-2-10 | ||
| 4 | I&HAS – glass break detectors | Test of properties and parameters Regulated area: Tests |
ČSN EN 50131-1 ed. 2; ČSN EN 50131-2-7-1, kap. 6; ČSN EN 50131-2-7-2, kap. 6; ČSN EN 50131-2-7-3, kap. 6 | ||
| 5 | I&HAS – shock (vibration) detectors | Test of properties and parameters Regulated area: Tests |
ČSN EN 50131-2-8, kap. 6; ČSN EN 50131-1 ed. 2 | ||
| 6 | I&HAS – directional detectors (AIBD, MW, dual) | Test of properties and parameters Regulated area: Tests |
ČSN CLC/TS 50131-2-9, kap. 6; ČSN EN 50131-1 ZMĚNA Z1:2000, příloha NJ; ČSN EN 50131-1 ed. 2 | ||
| 7 | I&HAS – warning devices and optical signalling | Test of properties and parameters Regulated area: Tests |
ČSN EN 50131-1 ed. 2; ČSN EN 50131-4:2008, kap 6; ČSN EN 50131-4 ed. 2, kap. 6 | ||
| 8 | I&HAS – wireless security systems, alarm transmission systems and alarm receiving centres | Test of properties and parameters Regulated area: Tests |
ČSN EN 50131-5-3 ed. 2; ČSN EN 50131-5-3:2006; ČSN EN 50136-1; ČSN EN 50136-2; ČSN EN 50136-3; ČSN EN 50131-10, kap. 10; ČSN CLC/TS 50131-12; ANSI/SIA DC-09-2007 příloha C; ČSN EN 50131-1 ZMĚNA Z1:2000, příloha NR, NP; ČSN EN 50131-1 ed. 2 | ||
| 9 | I&HAS – electronic access control systems and release locks | Test of properties and parameters Regulated area: Tests |
ČSN EN 60839-11-1; EN 60839-11-1:2013 | ||
| 10 | I&HAS – CCTV | Test of properties and parameters Regulated area: Tests |
ČSN EN 50132-7 ed. 2:2013; ČSN EN 62676-4; ČSN EN 50132-2-1:1999; ČSN EN 50132-4-1:2002 | ||
| 11 | I&HAS – social alarm systems, installation accessories (junction boxes, covers) | Test of properties and parameters Regulated area: Tests |
ČSN EN 50134-2 ed. 2; ČSN EN 50134-2:2001; ČSN CLC/TS 50131-11; ČSN EN 50134-1; ČSN EN 50134-3 ed. 2; ČSN EN 50134-5:2005; ČSN EN 50134-5 ed. 2; ČSN EN 50131-1 ZMĚNA Z1:2000, příloha NK | ||
| 12 | ZVB (high security locks) | Basic functional test of high security locks Regulated area: Tests |
ČSN EN 1300, čl. 8.2.5, 8.2.5.3, 8.2.5.4, 8.2.5.5, 8.2.5.6; ČSN EN 12320, čl. 5.5.8; ČSN EN 14846, čl. 6.10; ČSN EN 15684, čl. 5.4.2, 5.10.8, 5.10.9; ČSN EN 16864 čl. 5.4.2, 5.11.13, 5.11.14; ČSN EN 16867+A2, čl. 6.2.10, 6.2.12, 6.8.13, 6.8.14, 6.8.16, 6.8.17 | ||
| 13 | I&HAS – ALDDR detectors | Test of properties and parameters Regulated area: Tests |
ČSN CLC/TS 50131-2-11; ČSN EN 50131-1 ed. 2 | ||
| 14 | I&HAS – power supply | Test of properties and parameters Regulated area: Tests |
ČSN EN 50131-6 ed. 3; ČSN EN 50131-6 ed. 2:2008; ČSN EN 50131-1 ed. 2 | ||
| 15 | I&HAS – building communication systems | Test of properties and parameters Regulated area: Tests |
ČSN EN 62820-1-1 | ||
| 16 | I&HAS – all components | Tamper security test Regulated area: Tests |
ČSN EN 50131-1 ed. 2, kap. 8, čl. 8.7 | ||
| 17 | Metal detectors | Test of properties and parameters Regulated area: Tests |
NIJ STANDARD-0602.01:2000, kap. 3, 4 a 5; NIJ STANDARD-0601.02:2000, kap. 3, 4 a 5 | ||
| 18 | I&HAS – all components, ZVB (high security locks) | Dry heat test (operational, endurance) Regulated area: Tests |
ČSN EN 50130-5 ed. 2, kap. 8 a 9; ČSN EN 60068-2-2; ČSN EN 1125, čl. 6.2.2; ČSN EN 1303, čl. 6.7.2; ČSN EN 12209, čl. 5.10.2; ČSN EN 15684, čl. 5.7.3, 5.7.4, 5.7.5; ČSN EN 16864, čl. 5.7.3, 5.7.4, 5.7.5; ČSN EN 14846, čl. 6.7.2.1, 6.7.2.2, 6.7.3; ČSN EN 16867+A2, čl. 6.3.3, 6.6,4, 6.6.5; ČSN EN 1300, čl. 8.2.7.2; ČSN EN 179, čl. 6.2.2 | ||
| 19 | I&HAS – all components, ZVB (high security locks) | Cold test (operational) Regulated area: Tests |
ČSN EN 50130-5 ed. 2, kap. 10; ČSN EN 60068-2-1 ed. 2; ČSN EN 1125, čl. 6.2.2; ČSN EN 1303, čl. 6.7.2; ČSN EN 12320, čl. 5.5.8; ČSN EN 12209, čl. 5.10.2; ČSN EN 15684, čl. 5.7.4, 5.7.5; ČSN EN 16864, čl. 5.7.4, 5.7.5; ČSN EN 14846, čl. 6.7.2.1, 6.7.2.2; ČSN EN 16867+A2, čl. 6.6.4; ČSN EN 1300, čl. 8.2.7.1; ČSN EN 179, čl. 6.2.2 | ||
| 20 | I&HAS – all components | Change of temperature test (operational) Regulated area: Tests |
ČSN EN 50130-5 ed. 2, kap. 11; ČSN EN IEC 60068-2-14 ed. 3 | ||
| 21 | I&HAS – all components | Damp heat, steady state test (operational) Regulated area: Tests |
ČSN EN 50130-5 ed. 2, kap. 12; ČSN EN 60068-2-78 ed. 2 | ||
| 22 | I&HAS – all components | Damp heat, steady state test (endurance) Regulated area: Tests |
ČSN EN 50130-5 ed. 2, kap. 13; ČSN EN 60068-2-78 ed. 2 | ||
| 23 | I&HAS – all components, ZVB (high security locks) | Damp heat, cyclic test (operational) Regulated area: Tests |
ČSN EN 50130-5 ed. 2, kap. 14; ČSN EN 60068-2-30 ed. 2; ČSN EN 15684, čl. 5.7.5; ČSN EN 16864, čl. 5.7.5; ČSN EN 14846, čl. 6.7.3; ČSN EN 16867+A2, čl. 6.6.5 | ||
| 24 | I&HAS – all components | Damp heat, cyclic test (endurance) Regulated area: Tests |
ČSN EN 50130-5 ed. 2, kap. 15; ČSN EN 60068-2-30 ed. 2 | ||
| 25 | I&HAS – all components | Free fall test (operational) Regulated area: Tests |
ČSN EN 50130-5 ed. 2, kap. 21; ČSN EN 60068-2-31 | ||
| 26 | I&HAS – all components | Impact test (operational) Regulated area: Tests |
ČSN EN 50130-5 ed. 2, kap. 20; ČSN EN 60068-2-75 ed. 2, kap 6, 7 | ||
| 27 | I&HAS – all components | Immunity test to voltage dips and short interruptions of mains supply Regulated area: Tests |
ČSN EN 50130-4 ed. 2, kap. 8; ČSN EN 61000-4-11 ed. 2:2005; ČSN EN IEC 61000-4-11 ed. 3 | ||
| 28 | I&HAS – all components | Electrostatic discharge immunity test Regulated area: Tests |
ČSN EN 50130-4 ed. 2, kap. 9; ČSN EN 61000-4-2 ed. 2 | ||
| 29 | I&HAS – all components | Electrical fast transient immunity test Regulated area: Tests |
ČSN EN 50130-4 ed. 2, kap. 12; ČSN EN 61000-4-4 ed. 3 | ||
| 30 | I&HAS – all components | Function test under mains supply voltage variations Regulated area: Tests |
ČSN EN 50130-4 ed. 2, kap. 7 | ||
| 31 | I&HAS – all components | Surge immunity test Regulated area: Tests |
ČSN EN 50130-4 ed. 2, kap. 13; ČSN EN 61000-4-5 ed. 3 | ||
| 32 | I&HAS – all components | Measurement of conducted disturbance voltage at mains and telecommunication ports Regulated area: Tests |
ČSN EN 55032 ed. 2, kap. 6; ČSN EN IEC 61000-6-3 ed. 3 | ||
| 33 | I&HAS – all components | Measurement of radiated disturbance field Regulated area: Tests |
ČSN EN 55032 ed. 2, kap. 6; ČSN EN IEC 61000-6-3 ed. 3 | ||
| 34 | I&HAS – all components | Immunity test to disturbances induced by radio-frequency electromagnetic fields Regulated area: Tests |
ČSN EN 50130-4 ed. 2, kap. 11; ČSN EN IEC 61000-4-6 ed. 5 | ||
| 35 | I&HAS – perimeter systems | Test of properties and parameters of external perimeter security systems Regulated area: Tests |
ČSN CLC/TS 50661-1 | ||
| 36 | I&HAS – all components | System compatibility test of equipment located in supervised premises Regulated area: Tests |
ČSN CLC/TS 50131-5-4; ČSN CLC/TS 50131-5-1 | ||
| 37 | I&HAS – all components | Check of appropriate marking and accompanying product documentation Regulated area: Tests |
ČSN EN 50131-1 ed. 2, kap. 14 a 15 | ||
Reference standards (80)
ANSI/SIA DC-09-2007
EN 50131-2-2:2021
EN 50131-2-3:2021
EN 50131-2-4:2020
EN 60839-11-1:2013
NIJ STANDARD-0601.02:2000
NIJ STANDARD-0602.01:2000
ČSN CLC/TS 50131-11
ČSN CLC/TS 50131-12
ČSN CLC/TS 50131-2-11
ČSN CLC/TS 50131-2-9
ČSN CLC/TS 50131-5-1
ČSN CLC/TS 50131-5-4
ČSN CLC/TS 50131-9
ČSN CLC/TS 50661-1
ČSN EN 1125
ČSN EN 12209
ČSN EN 12320
ČSN EN 1300
ČSN EN 1303
ČSN EN 14846
ČSN EN 15684
ČSN EN 16864
ČSN EN 16867+A2
ČSN EN 179
ČSN EN 50130-4 ed. 2
ČSN EN 50130-5 ed. 2
ČSN EN 50131-1 ZMĚNA Z1:2000
ČSN EN 50131-1 ed. 2
ČSN EN 50131-10
ČSN EN 50131-2-10
ČSN EN 50131-2-2 ed. 2:2018
ČSN EN 50131-2-2 ed. 3
ČSN EN 50131-2-2:2008
ČSN EN 50131-2-3 ed. 2
ČSN EN 50131-2-3:2009
ČSN EN 50131-2-4 ed. 2
ČSN EN 50131-2-4:2009
ČSN EN 50131-2-6
ČSN EN 50131-2-7-1
ČSN EN 50131-2-7-2
ČSN EN 50131-2-7-3
ČSN EN 50131-2-8
ČSN EN 50131-3
ČSN EN 50131-4 ed. 2
ČSN EN 50131-4:2008
ČSN EN 50131-5-3 ed. 2
ČSN EN 50131-5-3:2006
ČSN EN 50131-6 ed. 2:2008
ČSN EN 50131-6 ed. 3
ČSN EN 50132-2-1:1999
ČSN EN 50132-4-1:2002
ČSN EN 50132-7 ed. 2:2013
ČSN EN 50134-1
ČSN EN 50134-2 ed. 2
ČSN EN 50134-2:2001
ČSN EN 50134-3 ed. 2
ČSN EN 50134-5 ed. 2
ČSN EN 50134-5:2005
ČSN EN 50136-1
ČSN EN 50136-2
ČSN EN 50136-3
ČSN EN 55032 ed. 2
ČSN EN 60068-2-1 ed. 2
ČSN EN 60068-2-2
ČSN EN 60068-2-30 ed. 2
ČSN EN 60068-2-31
ČSN EN 60068-2-75 ed. 2
ČSN EN 60068-2-78 ed. 2
ČSN EN 60839-11-1
ČSN EN 61000-4-11 ed. 2:2005
ČSN EN 61000-4-2 ed. 2
ČSN EN 61000-4-4 ed. 3
ČSN EN 61000-4-5 ed. 3
ČSN EN 62676-4
ČSN EN 62820-1-1
ČSN EN IEC 60068-2-14 ed. 3
ČSN EN IEC 61000-4-11 ed. 3
ČSN EN IEC 61000-4-6 ed. 5
ČSN EN IEC 61000-6-3 ed. 3