{"lab":{"_id":"69ad52a4de79e566650fd2b6","accr_number":"1172","country":"CZ","accr_body":"ČIA","address":"Popovova 1788/10, 143 00 Praha 4 - Modřany","categories":["electronics"],"city":"Praha 4 - Modřany","imported_at":"2026-03-08T10:42:44.590Z","methods_count":37,"name":"TESTALARM PRAHA spol. s r.o.","parse_status":"parsed","parse_version":5,"pdf_files":["1172_24_2026_CS.pdf","1172_24_2026_EN.pdf"],"scope_summary":"Badania systemów alarmowych, w zakresie określonym w załączniku do świadectwa.","search_text":"testalarm praha spol. s r.o. popovova 1788/10, 143 00 praha 4 - modřany 1172","status":"active","updated_at":"2026-03-08T14:52:08.221Z","valid_from":"","valid_until":"13-01-2031","website":"www.testalarm.cz","location":{"type":"Point","coordinates":[14.4378,50.0755]},"map_coord":[50.000143,14.419898],"map_geo":"nominatim-street","certificate_date":"13.01.2026","certificate_no":"24/2026","certificate_replaces":"663/2024 z 05.12.2024","en_official":false,"fields_of_testing":[{"codes":"","pl":"Badania systemów alarmowych, w zakresie określonym w załączniku do świadectwa.","en":"Testing of alarm systems, as specified in the appendix to this certificate.","zh":"报警系统检测，范围见本证书附件。","cs":"Zkoušení poplachových systémů, vymezené přílohou tohoto osvědčení."}],"flexible_scope":false,"flexible_scope_url":null,"has_en":true,"has_zh":true,"lab_division":"Laboratorium Badawcze","lab_division_cs":"Zkušební laboratoř","lab_division_en":"Testing Laboratory","lab_division_zh":"检测实验室","parse_date":"2026-09-28T12:00:00.000Z","parse_source":"reczna-analiza-labcoda-3","parsed_at":"2026-09-28T12:00:00.000Z","scope_legend":[{"abbr":"ARC","pl":"Centrum odbioru alarmów (Alarm Receiving Centre)","en":"Alarm Receiving Centre","zh":"报警接收中心","cs":"Poplachové přijímací centrum (Alarm Receiving Centre)"},{"abbr":"ATS","pl":"System transmisji alarmów (Alarm Transmission System)","en":"Alarm Transmission System","zh":"报警传输系统","cs":"Poplachový přenosový systém (Alarm Transmission System)"},{"abbr":"CCTV","pl":"Telewizja przemysłowa (Closed Circuit Television)","en":"Closed Circuit Television","zh":"闭路电视","cs":"Uzavřený televizní okruh (Closed Circuit Television)"},{"abbr":"CIE","pl":"Centrala I&HAS (Control and Indicating Equipment)","en":"I&HAS Control and Indicating Equipment","zh":"I&HAS控制和指示设备","cs":"Ústředna I&HAS (Control and Indicating Equipment)"},{"abbr":"CLC/TS","pl":"Specyfikacja techniczna wydana przez Europejski Komitet Normalizacyjny Elektrotechniki (CENELEC)","en":"Technical Specification issued by the European Committee for Electrotechnical Standardization","zh":"欧洲电工标准化委员会发布的技术规范","cs":"Technická specifikace vydaná Evropským výborem pro normalizaci v elektrotechnice"},{"abbr":"PZTS","pl":"Systemy sygnalizacji włamania i napadu","en":"Intrusion and hold-up alarm systems","zh":"入侵和紧急报警系统","cs":"Poplachové zabezpečovací a tísňové systémy"},{"abbr":"I&HAS","pl":"Systemy sygnalizacji włamania i napadu (Intrusion and Hold-up Alarm Systems)","en":"Intrusion and Hold-up Alarm Systems","zh":"入侵和紧急报警系统","cs":"Poplachové zabezpečovací a tísňové systémy (Intrusion and Hold-up Alarm Systems)"},{"abbr":"PS","pl":"Zasilacz (Power Supply)","en":"Power Supply","zh":"电源","cs":"Napájecí zdroj (Power Supply)"},{"abbr":"WD","pl":"Urządzenia ostrzegawcze (Warning Device)","en":"Warning Device","zh":"警报装置","cs":"Výstražná zařízení (Warning Device)"},{"abbr":"ZVB","pl":"Zamek o wysokim bezpieczeństwie (High Security Lock, HSL)","en":"High Security Lock (HSL)","zh":"高安全锁（HSL）","cs":"Zámek s vysokou bezpečností (High Security Lock (HSL)"},{"abbr":"NIJ","pl":"Narodowy Instytut Sprawiedliwości USA (National Institute of Justice)","en":"National Institute of Justice","zh":"美国国家司法研究所","cs":"Národní institute spravedlnosti (National Institute of Justice)"},{"abbr":"EACS","pl":"Elektroniczne systemy kontroli dostępu (Electronic access control systems)","en":"Electronic access control systems","zh":"电子门禁系统","cs":"Elektronické systémy kontroly vstupu (Electronic access control systems)"},{"abbr":"ANSI/SIA DC","pl":"Przepis Stowarzyszenia Branży Zabezpieczeń USA (SIA) dotyczący komunikacji w sieciach danych – zdarzenia przesyłane protokołem internetowym","en":"US Security Industry Association (SIA) standard for communication over data networks – events transmitted via Internet Protocol","zh":"美国安防行业协会（SIA）数据网络通信规范 – 经互联网协议传输的事件","cs":"Předpis Asociace bezpečnostního průmyslu USA (SIA) pro komunikaci po datových sítích - Události přenášené Internet protokolem"},{"abbr":"AIBD","pl":"Aktywna czujka z wiązkami podczerwieni (Active infrared beam detector)","en":"Active infrared beam detector","zh":"主动红外对射探测器","cs":"Aktivní detektor s infračervenými paprsky (Active infrared beam detector)"},{"abbr":"ALDDR","pl":"Aktywna czujka laserowa reagująca na odbicie rozproszone (Active Laser Detector Responsive to Diffuse Reflection)","en":"Active Laser Detector Responsive to Diffuse Reflection","zh":"漫反射主动激光探测器","cs":"Aktivní laserový detektor citlivý na difuzní odraz (Active Laser Detector Responsive to Diffuse Reflection)"}],"scope_notes":[],"source_lang":"cs","source_pdf_sha256":"5ad5bc627107eb831268e278e11c36b125572b69231b5b4d0c97c495b3ffd81c","source_pdf_url":"https://www.cai.cz/OA/pdf/24_2026_CS.pdf","source_pdf_url_en":null},"methods":[{"_id":"ea8f6ec5ca22621100201e8d","lab_id":"69ad52a4de79e566650fd2b6","country":"CZ","accr_number":"1172","accr_body":"ČIA","row_label":"1","test_object":"I&HAS – centrale","test_object_en":"I&HAS – control and indicating equipment","test_object_zh":"I&HAS – 控制中心","test_object_cs":"I&HAS – ústředny","methodology":"Badanie właściwości i parametrów","methodology_en":"Test of properties and parameters","methodology_zh":"性能和参数试验","methodology_cs":"Zkouška vlastností a parametrů","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Badanie właściwości i parametrów","reference":"ČSN EN 50131-1 ed. 2; ČSN EN 50131-3; ČSN CLC/TS 50131-12; ČSN CLC/TS 50131-9","norm_bases":["ČSN EN 50131-1 ed. 2","ČSN EN 50131-3","ČSN CLC/TS 50131-12","ČSN CLC/TS 50131-9"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Właściwości: przetwarzanie sygnałów lub komunikatów alarmowych, napadowych, sabotażowych i usterek, uzbrajanie i rozbrajanie; parametry: klucze mechaniczne i cyfrowe, kody PIN","note_en":"Properties: processing of intruder, hold-up, tamper and fault signals or messages, setting and unsetting; Parameters: mechanical and digital keys, PIN codes","note_zh":"性能：报警、紧急、防破坏和故障信号或消息处理，布防和撤防；参数：机械和数字钥匙、PIN码","note_cs":"Vlastnosti: zpracování poplachových, tísňových, sabotážních a poruchových signálů nebo zpráv, uvádění do stavu střežení a klidu; Parametry: mechanické a digitální klíče, PIN kódy","search_text":"I&HAS – centrale Badanie właściwości i parametrów I&HAS – ústředny Zkouška vlastností a parametrů ČSN EN 50131-1 ed. 2; ČSN EN 50131-3; ČSN CLC/TS 50131-12; ČSN CLC/TS 50131-9 I&HAS – centrale Badanie wlasciwosci i parametrow I&HAS – ustredny Zkouska vlastnosti a parametru CSN EN 50131-1 ed. 2; CSN EN 50131-3; CSN CLC/TS 50131-12; CSN CLC/TS 50131-9","search_en":"I&HAS – control and indicating equipment Test of properties and parameters ČSN EN 50131-1 ed. 2; ČSN EN 50131-3; ČSN CLC/TS 50131-12; ČSN CLC/TS 50131-9","search_zh":"I&HAS – 控制中心 性能和参数试验 ČSN EN 50131-1 ed. 2; ČSN EN 50131-3; ČSN CLC/TS 50131-12; ČSN CLC/TS 50131-9","categories":["electronics"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":0,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"51f665d4dd0ca1057b032fd9","lab_id":"69ad52a4de79e566650fd2b6","country":"CZ","accr_number":"1172","accr_body":"ČIA","row_label":"2","test_object":"I&HAS – pasywne czujki podczerwieni, czujki mikrofalowe i kombinowane","test_object_en":"I&HAS – passive infrared, microwave and combined detectors","test_object_zh":"I&HAS – 被动红外、微波和复合探测器","test_object_cs":"I&HAS – infrapasivní, mikrovlnné a kombinované detektory","methodology":"Badanie właściwości i parametrów","methodology_en":"Test of properties and parameters","methodology_zh":"性能和参数试验","methodology_cs":"Zkouška vlastností a parametrů","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Badanie właściwości i parametrów","reference":"EN 50131-2-2:2021, kap. 6; ČSN EN 50131-2-2 ed. 3, kap. 6; ČSN EN 50131-2-2 ed. 2:2018, kap. 6; ČSN EN 50131-2-2:2008, kap. 6; EN 50131-2-3:2021, kap. 6; ČSN EN 50131-2-3:2009, kap. 6; ČSN EN 50131-2-3 ed. 2, kap. 6; EN 50131-2-4:2020, kap. 6; ČSN EN 50131-2-4 ed. 2, kap. 6; ČSN EN 50131-2-4:2009, kap. 6; ČSN EN 50131-1 ed. 2","norm_bases":["EN 50131-2-2:2021","ČSN EN 50131-2-2 ed. 3","ČSN EN 50131-2-2 ed. 2:2018","ČSN EN 50131-2-2:2008","EN 50131-2-3:2021","ČSN EN 50131-2-3:2009","ČSN EN 50131-2-3 ed. 2","EN 50131-2-4:2020","ČSN EN 50131-2-4 ed. 2","ČSN EN 50131-2-4:2009","ČSN EN 50131-1 ed. 2"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":"Właściwości: weryfikacja funkcji wykrywania, autotesty, odporność na nieprawidłowe działanie, zabezpieczenie przed sabotażem; parametry: pobór prądu, zmiany napięcia","note_en":"Properties: verification of detection function, self-tests, immunity to malfunction, tamper security; Parameters: current consumption, voltage changes","note_zh":"性能：探测功能验证、自检、抗误动作、防破坏；参数：电流消耗、电压变化","note_cs":"Vlastnosti: ověření detekční funkce, autotesty, odolnost vůči chybné funkci, zabezpečení proti sabotáži; Parametry: odběr proudu, změny napětí","search_text":"I&HAS – pasywne czujki podczerwieni, czujki mikrofalowe i kombinowane Badanie właściwości i parametrów I&HAS – infrapasivní, mikrovlnné a kombinované detektory Zkouška vlastností a parametrů EN 50131-2-2:2021, kap. 6; ČSN EN 50131-2-2 ed. 3, kap. 6; ČSN EN 50131-2-2 ed. 2:2018, kap. 6; ČSN EN 50131-2-2:2008, kap. 6; EN 50131-2-3:2021, kap. 6; ČSN EN 50131-2-3:2009, kap. 6; ČSN EN 50131-2-3 ed. 2, kap. 6; EN 50131-2-4:2020, kap. 6; ČSN EN 50131-2-4 ed. 2, kap. 6; ČSN EN 50131-2-4:2009, kap. 6; ČSN EN 50131-1 ed. 2 I&HAS – pasywne czujki podczerwieni, czujki mikrofalowe i kombinowane Badanie wlasciwosci i parametrow I&HAS – infrapasivni, mikrovlnne a kombinovane detektory Zkouska vlastnosti a parametru EN 50131-2-2:2021, kap. 6; CSN EN 50131-2-2 ed. 3, kap. 6; CSN EN 50131-2-2 ed. 2:2018, kap. 6; CSN EN 50131-2-2:2008, kap. 6; EN 50131-2-3:2021, kap. 6; CSN EN 50131-2-3:2009, kap. 6; CSN EN 50131-2-3 ed. 2, kap. 6; EN 50131-2-4:2020, kap. 6; CSN EN 50131-2-4 ed. 2, kap. 6; CSN EN 50131-2-4:2009, kap. 6; CSN EN 50131-1 ed. 2","search_en":"I&HAS – passive infrared, microwave and combined detectors Test of properties and parameters EN 50131-2-2:2021, kap. 6; ČSN EN 50131-2-2 ed. 3, kap. 6; ČSN EN 50131-2-2 ed. 2:2018, kap. 6; ČSN EN 50131-2-2:2008, kap. 6; EN 50131-2-3:2021, kap. 6; ČSN EN 50131-2-3:2009, kap. 6; ČSN EN 50131-2-3 ed. 2, kap. 6; EN 50131-2-4:2020, kap. 6; ČSN EN 50131-2-4 ed. 2, kap. 6; ČSN EN 50131-2-4:2009, kap. 6; ČSN EN 50131-1 ed. 2","search_zh":"I&HAS – 被动红外、微波和复合探测器 性能和参数试验 EN 50131-2-2:2021, kap. 6; ČSN EN 50131-2-2 ed. 3, kap. 6; ČSN EN 50131-2-2 ed. 2:2018, kap. 6; ČSN EN 50131-2-2:2008, kap. 6; EN 50131-2-3:2021, kap. 6; ČSN EN 50131-2-3:2009, kap. 6; ČSN EN 50131-2-3 ed. 2, kap. 6; EN 50131-2-4:2020, kap. 6; ČSN EN 50131-2-4 ed. 2, kap. 6; ČSN EN 50131-2-4:2009, kap. 6; ČSN EN 50131-1 ed. 2","categories":["electronics"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":1,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"68a7412cb7c3ff65c78c91a7","lab_id":"69ad52a4de79e566650fd2b6","country":"CZ","accr_number":"1172","accr_body":"ČIA","row_label":"3","test_object":"I&HAS – czujki otwarcia i czujki stanu otwarcia","test_object_en":"I&HAS – opening contacts and opening status detectors","test_object_zh":"I&HAS – 开启探测器和开启状态探测器","test_object_cs":"I&HAS – detektory otevření a detektory stavu otevření","methodology":"Badanie właściwości i parametrów","methodology_en":"Test of properties and parameters","methodology_zh":"性能和参数试验","methodology_cs":"Zkouška vlastností a parametrů","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Badanie właściwości i parametrów","reference":"ČSN EN 50131-2-6, kap. 6; ČSN EN 50131-1 ed. 2; ČSN EN 50131-2-10","norm_bases":["ČSN EN 50131-2-6","ČSN EN 50131-1 ed. 2","ČSN EN 50131-2-10"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Właściwości: zabezpieczenie przed sabotażem, odstęp czasowy między sygnałami; parametry: odległości oddalenia i zbliżenia, pobór prądu, zmiany napięcia","note_en":"Properties: tamper security, time interval between signals; Parameters: separation and approach distances, current consumption, voltage changes","note_zh":"性能：防破坏、信号间隔时间；参数：分离和接近距离、电流消耗、电压变化","note_cs":"Vlastnosti: zabezpečení proti sabotáži, časový interval mezi signály; Parametry: oddalovací a přibližovací vzdálenosti, odběr proudu, změny napětí","search_text":"I&HAS – czujki otwarcia i czujki stanu otwarcia Badanie właściwości i parametrów I&HAS – detektory otevření a detektory stavu otevření Zkouška vlastností a parametrů ČSN EN 50131-2-6, kap. 6; ČSN EN 50131-1 ed. 2; ČSN EN 50131-2-10 I&HAS – czujki otwarcia i czujki stanu otwarcia Badanie wlasciwosci i parametrow I&HAS – detektory otevreni a detektory stavu otevreni Zkouska vlastnosti a parametru CSN EN 50131-2-6, kap. 6; CSN EN 50131-1 ed. 2; CSN EN 50131-2-10","search_en":"I&HAS – opening contacts and opening status detectors Test of properties and parameters ČSN EN 50131-2-6, kap. 6; ČSN EN 50131-1 ed. 2; ČSN EN 50131-2-10","search_zh":"I&HAS – 开启探测器和开启状态探测器 性能和参数试验 ČSN EN 50131-2-6, kap. 6; ČSN EN 50131-1 ed. 2; ČSN EN 50131-2-10","categories":["electronics"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":2,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"c3b0e16cc4434dc4104d87be","lab_id":"69ad52a4de79e566650fd2b6","country":"CZ","accr_number":"1172","accr_body":"ČIA","row_label":"4","test_object":"I&HAS – czujki zbicia szyby","test_object_en":"I&HAS – glass break detectors","test_object_zh":"I&HAS – 玻璃破碎探测器","test_object_cs":"I&HAS – detektory rozbití skla","methodology":"Badanie właściwości i parametrów","methodology_en":"Test of properties and parameters","methodology_zh":"性能和参数试验","methodology_cs":"Zkouška vlastností a parametrů","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Badanie właściwości i parametrów","reference":"ČSN EN 50131-1 ed. 2; ČSN EN 50131-2-7-1, kap. 6; ČSN EN 50131-2-7-2, kap. 6; ČSN EN 50131-2-7-3, kap. 6","norm_bases":["ČSN EN 50131-1 ed. 2","ČSN EN 50131-2-7-1","ČSN EN 50131-2-7-2","ČSN EN 50131-2-7-3"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Właściwości: odporność na fałszywe źródła alarmu, zabezpieczenie przed sabotażem; parametry: zasięg wykrywania, pobór prądu, zmiany napięcia","note_en":"Properties: immunity to false alarm sources, tamper security; Parameters: detection range, current consumption, voltage changes","note_zh":"性能：抗误报源、防破坏；参数：探测范围、电流消耗、电压变化","note_cs":"Vlastnosti: odolnost proti falešným zdrojům poplachu, zabezpečení proti sabotáži; Parametry: detekční rozsah, odběr proudu, změny napětí","search_text":"I&HAS – czujki zbicia szyby Badanie właściwości i parametrów I&HAS – detektory rozbití skla Zkouška vlastností a parametrů ČSN EN 50131-1 ed. 2; ČSN EN 50131-2-7-1, kap. 6; ČSN EN 50131-2-7-2, kap. 6; ČSN EN 50131-2-7-3, kap. 6 I&HAS – czujki zbicia szyby Badanie wlasciwosci i parametrow I&HAS – detektory rozbiti skla Zkouska vlastnosti a parametru CSN EN 50131-1 ed. 2; CSN EN 50131-2-7-1, kap. 6; CSN EN 50131-2-7-2, kap. 6; CSN EN 50131-2-7-3, kap. 6","search_en":"I&HAS – glass break detectors Test of properties and parameters ČSN EN 50131-1 ed. 2; ČSN EN 50131-2-7-1, kap. 6; ČSN EN 50131-2-7-2, kap. 6; ČSN EN 50131-2-7-3, kap. 6","search_zh":"I&HAS – 玻璃破碎探测器 性能和参数试验 ČSN EN 50131-1 ed. 2; ČSN EN 50131-2-7-1, kap. 6; ČSN EN 50131-2-7-2, kap. 6; ČSN EN 50131-2-7-3, kap. 6","categories":["electronics"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":3,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"1d26d6a437114be9f5ee0585","lab_id":"69ad52a4de79e566650fd2b6","country":"CZ","accr_number":"1172","accr_body":"ČIA","row_label":"5","test_object":"I&HAS – czujki wstrząsowe (wibracyjne)","test_object_en":"I&HAS – shock (vibration) detectors","test_object_zh":"I&HAS – 震动（振动）探测器","test_object_cs":"I&HAS – otřesové (vibrační) detektory","methodology":"Badanie właściwości i parametrów","methodology_en":"Test of properties and parameters","methodology_zh":"性能和参数试验","methodology_cs":"Zkouška vlastností a parametrů","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Badanie właściwości i parametrów","reference":"ČSN EN 50131-2-8, kap. 6; ČSN EN 50131-1 ed. 2","norm_bases":["ČSN EN 50131-2-8","ČSN EN 50131-1 ed. 2"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":"Właściwości: odporność na nieprawidłowe działanie, zabezpieczenie przed sabotażem; parametry: zasięg wykrywania, pobór prądu, zmiany napięcia","note_en":"Properties: immunity to incorrect operation, tamper security; Parameters: detection range, current consumption, voltage changes","note_zh":"性能：抗误动作、防破坏；参数：探测范围、电流消耗、电压变化","note_cs":"Vlastnosti: odolnost proti nesprávné činnosti, zabezpečení proti sabotáži; Parametry: detekční rozsah, odběr proudu, změny napětí","search_text":"I&HAS – czujki wstrząsowe (wibracyjne) Badanie właściwości i parametrów I&HAS – otřesové (vibrační) detektory Zkouška vlastností a parametrů ČSN EN 50131-2-8, kap. 6; ČSN EN 50131-1 ed. 2 I&HAS – czujki wstrzasowe (wibracyjne) Badanie wlasciwosci i parametrow I&HAS – otresove (vibracni) detektory Zkouska vlastnosti a parametru CSN EN 50131-2-8, kap. 6; CSN EN 50131-1 ed. 2","search_en":"I&HAS – shock (vibration) detectors Test of properties and parameters ČSN EN 50131-2-8, kap. 6; ČSN EN 50131-1 ed. 2","search_zh":"I&HAS – 震动（振动）探测器 性能和参数试验 ČSN EN 50131-2-8, kap. 6; ČSN EN 50131-1 ed. 2","categories":["electronics"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":4,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"c9fe3e943a20e41b559500bf","lab_id":"69ad52a4de79e566650fd2b6","country":"CZ","accr_number":"1172","accr_body":"ČIA","row_label":"6","test_object":"I&HAS – czujki kierunkowe (AIBD, MW, dualne)","test_object_en":"I&HAS – directional detectors (AIBD, MW, dual)","test_object_zh":"I&HAS – 定向探测器（AIBD、MW、双鉴）","test_object_cs":"I&HAS – směrové detektory (AIBD, MW, duální)","methodology":"Badanie właściwości i parametrów","methodology_en":"Test of properties and parameters","methodology_zh":"性能和参数试验","methodology_cs":"Zkouška vlastností a parametrů","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Badanie właściwości i parametrów","reference":"ČSN CLC/TS 50131-2-9, kap. 6; ČSN EN 50131-1 ZMĚNA Z1:2000, příloha NJ; ČSN EN 50131-1 ed. 2","norm_bases":["ČSN CLC/TS 50131-2-9","ČSN EN 50131-1 ZMĚNA Z1:2000","ČSN EN 50131-1 ed. 2"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":"Właściwości: weryfikacja funkcji wykrywania, autotesty, odporność na nieprawidłowe działanie; parametry: pobór prądu, zmiany napięcia","note_en":"Properties: verification of detection function, self-tests, immunity to malfunction; Parameters: current consumption, voltage changes","note_zh":"性能：探测功能验证、自检、抗误动作；参数：电流消耗、电压变化","note_cs":"Vlastnosti: ověření detekční funkce, autotesty, odolnost vůči chybné funkci; Parametry: odběr proudu, změny napětí","search_text":"I&HAS – czujki kierunkowe (AIBD, MW, dualne) Badanie właściwości i parametrów I&HAS – směrové detektory (AIBD, MW, duální) Zkouška vlastností a parametrů ČSN CLC/TS 50131-2-9, kap. 6; ČSN EN 50131-1 ZMĚNA Z1:2000, příloha NJ; ČSN EN 50131-1 ed. 2 I&HAS – czujki kierunkowe (AIBD, MW, dualne) Badanie wlasciwosci i parametrow I&HAS – smerove detektory (AIBD, MW, dualni) Zkouska vlastnosti a parametru CSN CLC/TS 50131-2-9, kap. 6; CSN EN 50131-1 ZMENA Z1:2000, priloha NJ; CSN EN 50131-1 ed. 2","search_en":"I&HAS – directional detectors (AIBD, MW, dual) Test of properties and parameters ČSN CLC/TS 50131-2-9, kap. 6; ČSN EN 50131-1 ZMĚNA Z1:2000, příloha NJ; ČSN EN 50131-1 ed. 2","search_zh":"I&HAS – 定向探测器（AIBD、MW、双鉴） 性能和参数试验 ČSN CLC/TS 50131-2-9, kap. 6; ČSN EN 50131-1 ZMĚNA Z1:2000, příloha NJ; ČSN EN 50131-1 ed. 2","categories":["electronics"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":5,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"8dcb6a0e3e65d988bed9a939","lab_id":"69ad52a4de79e566650fd2b6","country":"CZ","accr_number":"1172","accr_body":"ČIA","row_label":"7","test_object":"I&HAS – urządzenia ostrzegawcze i sygnalizacja optyczna","test_object_en":"I&HAS – warning devices and optical signalling","test_object_zh":"I&HAS – 警报装置和光信号","test_object_cs":"I&HAS – výstražná zařízení a optická signalizace","methodology":"Badanie właściwości i parametrów","methodology_en":"Test of properties and parameters","methodology_zh":"性能和参数试验","methodology_cs":"Zkouška vlastností a parametrů","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Badanie właściwości i parametrów","reference":"ČSN EN 50131-1 ed. 2; ČSN EN 50131-4:2008, kap 6; ČSN EN 50131-4 ed. 2, kap. 6","norm_bases":["ČSN EN 50131-1 ed. 2","ČSN EN 50131-4:2008","ČSN EN 50131-4 ed. 2"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":"Właściwości: reakcje na zdarzenia (polecenie aktywacji, integralność połączeń), zabezpieczenie przed sabotażem; parametry: poziom mocy akustycznej, czas trwania dźwięku, pobór prądu, zmiany napięcia","note_en":"Properties: responses to events (activation command, interconnection integrity), tamper security; Parameters: sound power level, sound duration, current consumption, voltage changes","note_zh":"性能：事件响应（激活指令、连接完整性）、防破坏；参数：声功率级、发声持续时间、电流消耗、电压变化","note_cs":"Vlastnosti: odezvy na události (aktivační povel, integrita propojení), zabezpečení proti sabotáži; Parametry: úroveň akustického výkonu, doba trvání zvuku, odběr proudu, změny napětí","search_text":"I&HAS – urządzenia ostrzegawcze i sygnalizacja optyczna Badanie właściwości i parametrów I&HAS – výstražná zařízení a optická signalizace Zkouška vlastností a parametrů ČSN EN 50131-1 ed. 2; ČSN EN 50131-4:2008, kap 6; ČSN EN 50131-4 ed. 2, kap. 6 I&HAS – urzadzenia ostrzegawcze i sygnalizacja optyczna Badanie wlasciwosci i parametrow I&HAS – vystrazna zarizeni a opticka signalizace Zkouska vlastnosti a parametru CSN EN 50131-1 ed. 2; CSN EN 50131-4:2008, kap 6; CSN EN 50131-4 ed. 2, kap. 6","search_en":"I&HAS – warning devices and optical signalling Test of properties and parameters ČSN EN 50131-1 ed. 2; ČSN EN 50131-4:2008, kap 6; ČSN EN 50131-4 ed. 2, kap. 6","search_zh":"I&HAS – 警报装置和光信号 性能和参数试验 ČSN EN 50131-1 ed. 2; ČSN EN 50131-4:2008, kap 6; ČSN EN 50131-4 ed. 2, kap. 6","categories":["electronics"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":6,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"ff0507b858063dd59dabb50c","lab_id":"69ad52a4de79e566650fd2b6","country":"CZ","accr_number":"1172","accr_body":"ČIA","row_label":"8","test_object":"I&HAS – bezprzewodowe systemy zabezpieczeń, systemy transmisji alarmów i centra odbioru alarmów","test_object_en":"I&HAS – wireless security systems, alarm transmission systems and alarm receiving centres","test_object_zh":"I&HAS – 无线安防系统、报警传输系统和报警接收中心","test_object_cs":"I&HAS – bezdrátové zabezpečovací systémy, poplachové přenosové systémy a poplachová přijímací centra","methodology":"Badanie właściwości i parametrów","methodology_en":"Test of properties and parameters","methodology_zh":"性能和参数试验","methodology_cs":"Zkouška vlastností a parametrů","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Badanie właściwości i parametrów","reference":"ČSN EN 50131-5-3 ed. 2; ČSN EN 50131-5-3:2006; ČSN EN 50136-1; ČSN EN 50136-2; ČSN EN 50136-3; ČSN EN 50131-10, kap. 10; ČSN CLC/TS 50131-12; ANSI/SIA DC-09-2007 příloha C; ČSN EN 50131-1 ZMĚNA Z1:2000, příloha NR, NP; ČSN EN 50131-1 ed. 2","norm_bases":["ČSN EN 50131-5-3 ed. 2","ČSN EN 50131-5-3:2006","ČSN EN 50136-1","ČSN EN 50136-2","ČSN EN 50136-3","ČSN EN 50131-10","ČSN CLC/TS 50131-12","ANSI/SIA DC-09-2007","ČSN EN 50131-1 ZMĚNA Z1:2000","ČSN EN 50131-1 ed. 2"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Właściwości: monitorowanie połączenia, zabezpieczenie komunikatów, dostępność, bezpieczeństwo, poziomy dostępu; parametry: czas transmisji, interwał raportowania","note_en":"Properties: link monitoring, message security, availability, security, access levels; Parameters: transmission time, reporting interval","note_zh":"性能：链路监控、消息安全、可用性、安全性、访问级别；参数：传输时间、报告间隔","note_cs":"Vlastnosti: monitorování spojení, zabezpečení zpráv, dostupnost, bezpečnost, přístupové úrovně; Parametry: doba přenosu, interval hlášení","search_text":"I&HAS – bezprzewodowe systemy zabezpieczeń, systemy transmisji alarmów i centra odbioru alarmów Badanie właściwości i parametrów I&HAS – bezdrátové zabezpečovací systémy, poplachové přenosové systémy a poplachová přijímací centra Zkouška vlastností a parametrů ČSN EN 50131-5-3 ed. 2; ČSN EN 50131-5-3:2006; ČSN EN 50136-1; ČSN EN 50136-2; ČSN EN 50136-3; ČSN EN 50131-10, kap. 10; ČSN CLC/TS 50131-12; ANSI/SIA DC-09-2007 příloha C; ČSN EN 50131-1 ZMĚNA Z1:2000, příloha NR, NP; ČSN EN 50131-1 ed. 2 I&HAS – bezprzewodowe systemy zabezpieczen, systemy transmisji alarmow i centra odbioru alarmow Badanie wlasciwosci i parametrow I&HAS – bezdratove zabezpecovaci systemy, poplachove prenosove systemy a poplachova prijimaci centra Zkouska vlastnosti a parametru CSN EN 50131-5-3 ed. 2; CSN EN 50131-5-3:2006; CSN EN 50136-1; CSN EN 50136-2; CSN EN 50136-3; CSN EN 50131-10, kap. 10; CSN CLC/TS 50131-12; ANSI/SIA DC-09-2007 priloha C; CSN EN 50131-1 ZMENA Z1:2000, priloha NR, NP; CSN EN 50131-1 ed. 2","search_en":"I&HAS – wireless security systems, alarm transmission systems and alarm receiving centres Test of properties and parameters ČSN EN 50131-5-3 ed. 2; ČSN EN 50131-5-3:2006; ČSN EN 50136-1; ČSN EN 50136-2; ČSN EN 50136-3; ČSN EN 50131-10, kap. 10; ČSN CLC/TS 50131-12; ANSI/SIA DC-09-2007 příloha C; ČSN EN 50131-1 ZMĚNA Z1:2000, příloha NR, NP; ČSN EN 50131-1 ed. 2","search_zh":"I&HAS – 无线安防系统、报警传输系统和报警接收中心 性能和参数试验 ČSN EN 50131-5-3 ed. 2; ČSN EN 50131-5-3:2006; ČSN EN 50136-1; ČSN EN 50136-2; ČSN EN 50136-3; ČSN EN 50131-10, kap. 10; ČSN CLC/TS 50131-12; ANSI/SIA DC-09-2007 příloha C; ČSN EN 50131-1 ZMĚNA Z1:2000, příloha NR, NP; ČSN EN 50131-1 ed. 2","categories":["electronics"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":7,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"593edd0a70833dec48874142","lab_id":"69ad52a4de79e566650fd2b6","country":"CZ","accr_number":"1172","accr_body":"ČIA","row_label":"9","test_object":"I&HAS – elektroniczne systemy kontroli dostępu i zamki przepustowe","test_object_en":"I&HAS – electronic access control systems and release locks","test_object_zh":"I&HAS – 电子门禁系统和通行锁","test_object_cs":"I&HAS – elektronické systémy kontroly vstupu a propouštěcí zámky","methodology":"Badanie właściwości i parametrów","methodology_en":"Test of properties and parameters","methodology_zh":"性能和参数试验","methodology_cs":"Zkouška vlastností a parametrů","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Badanie właściwości i parametrów","reference":"ČSN EN 60839-11-1; EN 60839-11-1:2013","norm_bases":["ČSN EN 60839-11-1","EN 60839-11-1:2013"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Właściwości: interfejs punktu dostępu, sygnalizacja i raportowanie, rozpoznawanie, przymus, obejście, zabezpieczenie przed sabotażem; parametry: napięcie zasilania, pojemność rezerwowego źródła zasilania","note_en":"Properties: access point interface, indication and annunciation, recognition, duress, override, tamper security; Parameters: supply voltage, backup power source capacity","note_zh":"性能：出入口接口、指示和通报、识别、胁迫、旁路、防破坏；参数：供电电压、备用电源容量","note_cs":"Vlastnosti: interface místa přístupu, indikace a hlášení, rozpoznávání, nátlak, přemostění, zabezpečení proti sabotáži; Parametry: napájecí napětí, kapacita záložního zdroje napájení","search_text":"I&HAS – elektroniczne systemy kontroli dostępu i zamki przepustowe Badanie właściwości i parametrów I&HAS – elektronické systémy kontroly vstupu a propouštěcí zámky Zkouška vlastností a parametrů ČSN EN 60839-11-1; EN 60839-11-1:2013 I&HAS – elektroniczne systemy kontroli dostepu i zamki przepustowe Badanie wlasciwosci i parametrow I&HAS – elektronicke systemy kontroly vstupu a propousteci zamky Zkouska vlastnosti a parametru CSN EN 60839-11-1; EN 60839-11-1:2013","search_en":"I&HAS – electronic access control systems and release locks Test of properties and parameters ČSN EN 60839-11-1; EN 60839-11-1:2013","search_zh":"I&HAS – 电子门禁系统和通行锁 性能和参数试验 ČSN EN 60839-11-1; EN 60839-11-1:2013","categories":["electronics"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":8,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"43f3597efb3850e27c289237","lab_id":"69ad52a4de79e566650fd2b6","country":"CZ","accr_number":"1172","accr_body":"ČIA","row_label":"10","test_object":"I&HAS – CCTV","test_object_en":"I&HAS – CCTV","test_object_zh":"I&HAS – 闭路电视","test_object_cs":"I&HAS – CCTV","methodology":"Badanie właściwości i parametrów","methodology_en":"Test of properties and parameters","methodology_zh":"性能和参数试验","methodology_cs":"Zkouška vlastností a parametrů","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Badanie właściwości i parametrów","reference":"ČSN EN 50132-7 ed. 2:2013; ČSN EN 62676-4; ČSN EN 50132-2-1:1999; ČSN EN 50132-4-1:2002","norm_bases":["ČSN EN 50132-7 ed. 2:2013","ČSN EN 62676-4","ČSN EN 50132-2-1:1999","ČSN EN 50132-4-1:2002"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Właściwości: zabezpieczenie przed sabotażem, dobór obiektywu, właściwości funkcjonalne wideo; parametry: pole widzenia, oświetlenie, rozdzielczość, zasilanie","note_en":"Properties: tamper security, lens selection, video functional properties; Parameters: field of view, illumination, resolution, power supply","note_zh":"性能：防破坏、镜头选择、视频功能性能；参数：视场、照度、分辨率、供电","note_cs":"Vlastnosti: zabezpečení proti sabotáži, výběr objektivu, funkční vlastnosti videa; Parametry: zorné pole, osvětlení, rozlišení, napájení","search_text":"I&HAS – CCTV Badanie właściwości i parametrów I&HAS – CCTV Zkouška vlastností a parametrů ČSN EN 50132-7 ed. 2:2013; ČSN EN 62676-4; ČSN EN 50132-2-1:1999; ČSN EN 50132-4-1:2002 I&HAS – CCTV Badanie wlasciwosci i parametrow I&HAS – CCTV Zkouska vlastnosti a parametru CSN EN 50132-7 ed. 2:2013; CSN EN 62676-4; CSN EN 50132-2-1:1999; CSN EN 50132-4-1:2002","search_en":"I&HAS – CCTV Test of properties and parameters ČSN EN 50132-7 ed. 2:2013; ČSN EN 62676-4; ČSN EN 50132-2-1:1999; ČSN EN 50132-4-1:2002","search_zh":"I&HAS – 闭路电视 性能和参数试验 ČSN EN 50132-7 ed. 2:2013; ČSN EN 62676-4; ČSN EN 50132-2-1:1999; ČSN EN 50132-4-1:2002","categories":["electronics"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":9,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"b864a8f0a751255fe914e011","lab_id":"69ad52a4de79e566650fd2b6","country":"CZ","accr_number":"1172","accr_body":"ČIA","row_label":"11","test_object":"I&HAS – systemy przywoływania pomocy, osprzęt instalacyjny (puszki rozgałęźne, osłony)","test_object_en":"I&HAS – social alarm systems, installation accessories (junction boxes, covers)","test_object_zh":"I&HAS – 求助呼叫系统、安装附件（接线盒、外壳）","test_object_cs":"I&HAS – systémy přivolání pomoci, instalační prostředky (rozvodné krabice, kryty)","methodology":"Badanie właściwości i parametrów","methodology_en":"Test of properties and parameters","methodology_zh":"性能和参数试验","methodology_cs":"Zkouška vlastností a parametrů","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Badanie właściwości i parametrów","reference":"ČSN EN 50134-2 ed. 2; ČSN EN 50134-2:2001; ČSN CLC/TS 50131-11; ČSN EN 50134-1; ČSN EN 50134-3 ed. 2; ČSN EN 50134-5:2005; ČSN EN 50134-5 ed. 2; ČSN EN 50131-1 ZMĚNA Z1:2000, příloha NK","norm_bases":["ČSN EN 50134-2 ed. 2","ČSN EN 50134-2:2001","ČSN CLC/TS 50131-11","ČSN EN 50134-1","ČSN EN 50134-3 ed. 2","ČSN EN 50134-5:2005","ČSN EN 50134-5 ed. 2","ČSN EN 50131-1 ZMĚNA Z1:2000"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Właściwości: zabezpieczenie przed sabotażem, wytrzymałość mechaniczna; parametry: rezystancja przejścia i izolacji styku mechanicznego, graniczna siła wyzwalania","note_en":"Properties: tamper security, mechanical resistance; Parameters: contact and insulation resistance of the mechanical contact, limit actuating force","note_zh":"性能：防破坏、机械强度；参数：机械触点接触电阻和绝缘电阻、极限触发力","note_cs":"Vlastnosti: zabezpečení proti sabotáži, mechanická odolnost; Parametry: přechodový a izolační odpor mechanického kontaktu, mezní spouštěcí síla","search_text":"I&HAS – systemy przywoływania pomocy, osprzęt instalacyjny (puszki rozgałęźne, osłony) Badanie właściwości i parametrów I&HAS – systémy přivolání pomoci, instalační prostředky (rozvodné krabice, kryty) Zkouška vlastností a parametrů ČSN EN 50134-2 ed. 2; ČSN EN 50134-2:2001; ČSN CLC/TS 50131-11; ČSN EN 50134-1; ČSN EN 50134-3 ed. 2; ČSN EN 50134-5:2005; ČSN EN 50134-5 ed. 2; ČSN EN 50131-1 ZMĚNA Z1:2000, příloha NK I&HAS – systemy przywolywania pomocy, osprzet instalacyjny (puszki rozgalezne, oslony) Badanie wlasciwosci i parametrow I&HAS – systemy privolani pomoci, instalacni prostredky (rozvodne krabice, kryty) Zkouska vlastnosti a parametru CSN EN 50134-2 ed. 2; CSN EN 50134-2:2001; CSN CLC/TS 50131-11; CSN EN 50134-1; CSN EN 50134-3 ed. 2; CSN EN 50134-5:2005; CSN EN 50134-5 ed. 2; CSN EN 50131-1 ZMENA Z1:2000, priloha NK","search_en":"I&HAS – social alarm systems, installation accessories (junction boxes, covers) Test of properties and parameters ČSN EN 50134-2 ed. 2; ČSN EN 50134-2:2001; ČSN CLC/TS 50131-11; ČSN EN 50134-1; ČSN EN 50134-3 ed. 2; ČSN EN 50134-5:2005; ČSN EN 50134-5 ed. 2; ČSN EN 50131-1 ZMĚNA Z1:2000, příloha NK","search_zh":"I&HAS – 求助呼叫系统、安装附件（接线盒、外壳） 性能和参数试验 ČSN EN 50134-2 ed. 2; ČSN EN 50134-2:2001; ČSN CLC/TS 50131-11; ČSN EN 50134-1; ČSN EN 50134-3 ed. 2; ČSN EN 50134-5:2005; ČSN EN 50134-5 ed. 2; ČSN EN 50131-1 ZMĚNA Z1:2000, příloha NK","categories":["electronics"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":10,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"376f79c8abbbe5fa62ccdac2","lab_id":"69ad52a4de79e566650fd2b6","country":"CZ","accr_number":"1172","accr_body":"ČIA","row_label":"12","test_object":"ZVB (zamki o wysokim bezpieczeństwie)","test_object_en":"ZVB (high security locks)","test_object_zh":"高安全锁（ZVB）","test_object_cs":"ZVB","methodology":"Podstawowe badanie funkcjonalne zamków o wysokim bezpieczeństwie","methodology_en":"Basic functional test of high security locks","methodology_zh":"高安全锁基本功能试验","methodology_cs":"Základní funkční zkouška zámků s vysokou bezpečností","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Podstawowe badanie funkcjonalne zamków o wysokim bezpieczeństwie","reference":"ČSN EN 1300, čl. 8.2.5, 8.2.5.3, 8.2.5.4, 8.2.5.5, 8.2.5.6; ČSN EN 12320, čl. 5.5.8; ČSN EN 14846, čl. 6.10; ČSN EN 15684, čl. 5.4.2, 5.10.8, 5.10.9; ČSN EN 16864 čl. 5.4.2, 5.11.13, 5.11.14; ČSN EN 16867+A2, čl. 6.2.10, 6.2.12, 6.8.13, 6.8.14, 6.8.16, 6.8.17","norm_bases":["ČSN EN 1300","ČSN EN 12320","ČSN EN 14846","ČSN EN 15684","ČSN EN 16864","ČSN EN 16867+A2"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"ZVB (zamki o wysokim bezpieczeństwie) Podstawowe badanie funkcjonalne zamków o wysokim bezpieczeństwie ZVB Základní funkční zkouška zámků s vysokou bezpečností ČSN EN 1300, čl. 8.2.5, 8.2.5.3, 8.2.5.4, 8.2.5.5, 8.2.5.6; ČSN EN 12320, čl. 5.5.8; ČSN EN 14846, čl. 6.10; ČSN EN 15684, čl. 5.4.2, 5.10.8, 5.10.9; ČSN EN 16864 čl. 5.4.2, 5.11.13, 5.11.14; ČSN EN 16867+A2, čl. 6.2.10, 6.2.12, 6.8.13, 6.8.14, 6.8.16, 6.8.17 ZVB (zamki o wysokim bezpieczenstwie) Podstawowe badanie funkcjonalne zamkow o wysokim bezpieczenstwie ZVB Zakladni funkcni zkouska zamku s vysokou bezpecnosti CSN EN 1300, cl. 8.2.5, 8.2.5.3, 8.2.5.4, 8.2.5.5, 8.2.5.6; CSN EN 12320, cl. 5.5.8; CSN EN 14846, cl. 6.10; CSN EN 15684, cl. 5.4.2, 5.10.8, 5.10.9; CSN EN 16864 cl. 5.4.2, 5.11.13, 5.11.14; CSN EN 16867+A2, cl. 6.2.10, 6.2.12, 6.8.13, 6.8.14, 6.8.16, 6.8.17","search_en":"ZVB (high security locks) Basic functional test of high security locks ČSN EN 1300, čl. 8.2.5, 8.2.5.3, 8.2.5.4, 8.2.5.5, 8.2.5.6; ČSN EN 12320, čl. 5.5.8; ČSN EN 14846, čl. 6.10; ČSN EN 15684, čl. 5.4.2, 5.10.8, 5.10.9; ČSN EN 16864 čl. 5.4.2, 5.11.13, 5.11.14; ČSN EN 16867+A2, čl. 6.2.10, 6.2.12, 6.8.13, 6.8.14, 6.8.16, 6.8.17","search_zh":"高安全锁（ZVB） 高安全锁基本功能试验 ČSN EN 1300, čl. 8.2.5, 8.2.5.3, 8.2.5.4, 8.2.5.5, 8.2.5.6; ČSN EN 12320, čl. 5.5.8; ČSN EN 14846, čl. 6.10; ČSN EN 15684, čl. 5.4.2, 5.10.8, 5.10.9; ČSN EN 16864 čl. 5.4.2, 5.11.13, 5.11.14; ČSN EN 16867+A2, čl. 6.2.10, 6.2.12, 6.8.13, 6.8.14, 6.8.16, 6.8.17","categories":["electronics"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":11,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"2adb82aec9e38fd2b373ca88","lab_id":"69ad52a4de79e566650fd2b6","country":"CZ","accr_number":"1172","accr_body":"ČIA","row_label":"13","test_object":"I&HAS – czujki ALDDR","test_object_en":"I&HAS – ALDDR detectors","test_object_zh":"I&HAS – ALDDR探测器","test_object_cs":"I&HAS – detektory ALDDR","methodology":"Badanie właściwości i parametrów","methodology_en":"Test of properties and parameters","methodology_zh":"性能和参数试验","methodology_cs":"Zkouška vlastností a parametrů","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Badanie właściwości i parametrów","reference":"ČSN CLC/TS 50131-2-11; ČSN EN 50131-1 ed. 2","norm_bases":["ČSN CLC/TS 50131-2-11","ČSN EN 50131-1 ed. 2"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":"Właściwości: weryfikacja funkcji wykrywania, autotesty, odporność na nieprawidłowe działanie, zabezpieczenie przed sabotażem; parametry: pobór prądu, zmiany napięcia","note_en":"Properties: verification of detection function, self-tests, immunity to malfunction, tamper security; Parameters: current consumption, voltage changes","note_zh":"性能：探测功能验证、自检、抗误动作、防破坏；参数：电流消耗、电压变化","note_cs":"Vlastnosti: ověření detekční funkce, autotesty, odolnost vůči chybné funkci, zabezpečení proti sabotáži; Parametry: odběr proudu, změny napětí","search_text":"I&HAS – czujki ALDDR Badanie właściwości i parametrów I&HAS – detektory ALDDR Zkouška vlastností a parametrů ČSN CLC/TS 50131-2-11; ČSN EN 50131-1 ed. 2 I&HAS – czujki ALDDR Badanie wlasciwosci i parametrow I&HAS – detektory ALDDR Zkouska vlastnosti a parametru CSN CLC/TS 50131-2-11; CSN EN 50131-1 ed. 2","search_en":"I&HAS – ALDDR detectors Test of properties and parameters ČSN CLC/TS 50131-2-11; ČSN EN 50131-1 ed. 2","search_zh":"I&HAS – ALDDR探测器 性能和参数试验 ČSN CLC/TS 50131-2-11; ČSN EN 50131-1 ed. 2","categories":["electronics"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":12,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"de87afce35269addd716932d","lab_id":"69ad52a4de79e566650fd2b6","country":"CZ","accr_number":"1172","accr_body":"ČIA","row_label":"14","test_object":"I&HAS – zasilacz","test_object_en":"I&HAS – power supply","test_object_zh":"I&HAS – 电源","test_object_cs":"I&HAS – napájecí zdroj","methodology":"Badanie właściwości i parametrów","methodology_en":"Test of properties and parameters","methodology_zh":"性能和参数试验","methodology_cs":"Zkouška vlastností a parametrů","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Badanie właściwości i parametrów","reference":"ČSN EN 50131-6 ed. 3; ČSN EN 50131-6 ed. 2:2008; ČSN EN 50131-1 ed. 2","norm_bases":["ČSN EN 50131-6 ed. 3","ČSN EN 50131-6 ed. 2:2008","ČSN EN 50131-1 ed. 2"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Właściwości: zabezpieczenie przed sabotażem, ochrona (przed przepięciem, zwarciem, przeciążeniem i głębokim rozładowaniem); parametry: ładowanie zasilacza, obciążenie zasilacza","note_en":"Properties: tamper security, protection (against overvoltage, short circuit, overload and deep discharge); Parameters: power supply recharging, power supply load","note_zh":"性能：防破坏、保护（过压、短路、过载和深度放电）；参数：电源充电、电源负载","note_cs":"Vlastnosti: zabezpečení proti sabotáži, ochrana (proti přepětí, zkratu, přetížení a hlubokému vybití); Parametry: dobíjení napájecího zdroje, zatížení napájecího zdroje","search_text":"I&HAS – zasilacz Badanie właściwości i parametrów I&HAS – napájecí zdroj Zkouška vlastností a parametrů ČSN EN 50131-6 ed. 3; ČSN EN 50131-6 ed. 2:2008; ČSN EN 50131-1 ed. 2 I&HAS – zasilacz Badanie wlasciwosci i parametrow I&HAS – napajeci zdroj Zkouska vlastnosti a parametru CSN EN 50131-6 ed. 3; CSN EN 50131-6 ed. 2:2008; CSN EN 50131-1 ed. 2","search_en":"I&HAS – power supply Test of properties and parameters ČSN EN 50131-6 ed. 3; ČSN EN 50131-6 ed. 2:2008; ČSN EN 50131-1 ed. 2","search_zh":"I&HAS – 电源 性能和参数试验 ČSN EN 50131-6 ed. 3; ČSN EN 50131-6 ed. 2:2008; ČSN EN 50131-1 ed. 2","categories":["electronics"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":13,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"8b555daf635c7eb19e0e525b","lab_id":"69ad52a4de79e566650fd2b6","country":"CZ","accr_number":"1172","accr_body":"ČIA","row_label":"15","test_object":"I&HAS – systemy komunikacji w budynkach","test_object_en":"I&HAS – building communication systems","test_object_zh":"I&HAS – 楼宇通信系统","test_object_cs":"I&HAS – komunikační systémy budov","methodology":"Badanie właściwości i parametrów","methodology_en":"Test of properties and parameters","methodology_zh":"性能和参数试验","methodology_cs":"Zkouška vlastností a parametrů","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Badanie właściwości i parametrów","reference":"ČSN EN 62820-1-1","norm_bases":["ČSN EN 62820-1-1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":"Właściwości: konstrukcja mechaniczna, wymagania bezpieczeństwa, czułość, zniekształcenia; parametry: charakterystyki wideo, ciśnienie akustyczne, głośność","note_en":"Properties: mechanical construction, safety requirements, sensitivity, distortion; Parameters: video characteristics, sound pressure, loudness","note_zh":"性能：机械结构、安全要求、灵敏度、失真；参数：视频特性、声压、音量","note_cs":"Vlastnosti: mechanická konstrukce, bezpečnostní požadavky, citlivost, zkreslení; Parametry: video charakteristiky, akustický tlak, hlasitost","search_text":"I&HAS – systemy komunikacji w budynkach Badanie właściwości i parametrów I&HAS – komunikační systémy budov Zkouška vlastností a parametrů ČSN EN 62820-1-1 I&HAS – systemy komunikacji w budynkach Badanie wlasciwosci i parametrow I&HAS – komunikacni systemy budov Zkouska vlastnosti a parametru CSN EN 62820-1-1","search_en":"I&HAS – building communication systems Test of properties and parameters ČSN EN 62820-1-1","search_zh":"I&HAS – 楼宇通信系统 性能和参数试验 ČSN EN 62820-1-1","categories":["electronics"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":14,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"a596c2ba2491baaaecbb7731","lab_id":"69ad52a4de79e566650fd2b6","country":"CZ","accr_number":"1172","accr_body":"ČIA","row_label":"16","test_object":"I&HAS – wszystkie części","test_object_en":"I&HAS – all components","test_object_zh":"I&HAS – 所有部件","test_object_cs":"I&HAS – všechny části","methodology":"Badanie zabezpieczenia przed sabotażem","methodology_en":"Tamper security test","methodology_zh":"防破坏试验","methodology_cs":"Zkouška zabezpečení proti sabotáži","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Badanie zabezpieczenia przed sabotażem","reference":"ČSN EN 50131-1 ed. 2, kap. 8, čl. 8.7","norm_bases":["ČSN EN 50131-1 ed. 2"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"I&HAS – wszystkie części Badanie zabezpieczenia przed sabotażem I&HAS – všechny části Zkouška zabezpečení proti sabotáži ČSN EN 50131-1 ed. 2, kap. 8, čl. 8.7 I&HAS – wszystkie czesci Badanie zabezpieczenia przed sabotazem I&HAS – vsechny casti Zkouska zabezpeceni proti sabotazi CSN EN 50131-1 ed. 2, kap. 8, cl. 8.7","search_en":"I&HAS – all components Tamper security test ČSN EN 50131-1 ed. 2, kap. 8, čl. 8.7","search_zh":"I&HAS – 所有部件 防破坏试验 ČSN EN 50131-1 ed. 2, kap. 8, čl. 8.7","categories":["electronics"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":15,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"1fe178de395d21045e6adcfb","lab_id":"69ad52a4de79e566650fd2b6","country":"CZ","accr_number":"1172","accr_body":"ČIA","row_label":"17","test_object":"Wykrywacze metali","test_object_en":"Metal detectors","test_object_zh":"金属探测器","test_object_cs":"Detektory kovů","methodology":"Badanie właściwości i parametrów","methodology_en":"Test of properties and parameters","methodology_zh":"性能和参数试验","methodology_cs":"Zkouška vlastností a parametrů","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Badanie właściwości i parametrów","reference":"NIJ STANDARD-0602.01:2000, kap. 3, 4 a 5; NIJ STANDARD-0601.02:2000, kap. 3, 4 a 5","norm_bases":["NIJ STANDARD-0602.01:2000","NIJ STANDARD-0601.02:2000"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":"Właściwości: zdolność wykrywania poszczególnych potencjalnych broni (noże, pistolety); parametry: napięcie zasilania, wymiary (strefy wykrywania)","note_en":"Properties: detection capability for individual potential weapons (knives, pistols); Parameters: supply voltage, dimensions (detection zones)","note_zh":"性能：对各类潜在武器（刀具、手枪）的探测能力；参数：供电电压、尺寸（探测区域）","note_cs":"Vlastnosti: detekční schopnost na jednotlivé potencionální zbraně (nože, pistole); Parametry: napájecí napětí, rozměry (detekční místa)","search_text":"Wykrywacze metali Badanie właściwości i parametrów Detektory kovů Zkouška vlastností a parametrů NIJ STANDARD-0602.01:2000, kap. 3, 4 a 5; NIJ STANDARD-0601.02:2000, kap. 3, 4 a 5 Wykrywacze metali Badanie wlasciwosci i parametrow Detektory kovu Zkouska vlastnosti a parametru NIJ STANDARD-0602.01:2000, kap. 3, 4 a 5; NIJ STANDARD-0601.02:2000, kap. 3, 4 a 5","search_en":"Metal detectors Test of properties and parameters NIJ STANDARD-0602.01:2000, kap. 3, 4 a 5; NIJ STANDARD-0601.02:2000, kap. 3, 4 a 5","search_zh":"金属探测器 性能和参数试验 NIJ STANDARD-0602.01:2000, kap. 3, 4 a 5; NIJ STANDARD-0601.02:2000, kap. 3, 4 a 5","categories":["electronics"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":16,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"34b22bbf02986b485f32c64f","lab_id":"69ad52a4de79e566650fd2b6","country":"CZ","accr_number":"1172","accr_body":"ČIA","row_label":"18","test_object":"I&HAS – wszystkie części, ZVB (zamki o wysokim bezpieczeństwie)","test_object_en":"I&HAS – all components, ZVB (high security locks)","test_object_zh":"I&HAS – 所有部件、高安全锁（ZVB）","test_object_cs":"I&HAS – všechny části, ZVB","methodology":"Badanie odporności na suche gorąco (funkcjonalne, wytrzymałościowe)","methodology_en":"Dry heat test (operational, endurance)","methodology_zh":"耐干热试验（运行、耐久）","methodology_cs":"Zkouška odolnosti proti suchému teplu (provozní, odolnostní)","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Badanie odporności na suche gorąco (funkcjonalne, wytrzymałościowe)","reference":"ČSN EN 50130-5 ed. 2, kap. 8 a 9; ČSN EN 60068-2-2; ČSN EN 1125, čl. 6.2.2; ČSN EN 1303, čl. 6.7.2; ČSN EN 12209, čl. 5.10.2; ČSN EN 15684, čl. 5.7.3, 5.7.4, 5.7.5; ČSN EN 16864, čl. 5.7.3, 5.7.4, 5.7.5; ČSN EN 14846, čl. 6.7.2.1, 6.7.2.2, 6.7.3; ČSN EN 16867+A2, čl. 6.3.3, 6.6,4, 6.6.5; ČSN EN 1300, čl. 8.2.7.2; ČSN EN 179, čl. 6.2.2","norm_bases":["ČSN EN 50130-5 ed. 2","ČSN EN 60068-2-2","ČSN EN 1125","ČSN EN 1303","ČSN EN 12209","ČSN EN 15684","ČSN EN 16864","ČSN EN 14846","ČSN EN 16867+A2","ČSN EN 1300","ČSN EN 179"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"I&HAS – wszystkie części, ZVB (zamki o wysokim bezpieczeństwie) Badanie odporności na suche gorąco (funkcjonalne, wytrzymałościowe) I&HAS – všechny části, ZVB Zkouška odolnosti proti suchému teplu (provozní, odolnostní) ČSN EN 50130-5 ed. 2, kap. 8 a 9; ČSN EN 60068-2-2; ČSN EN 1125, čl. 6.2.2; ČSN EN 1303, čl. 6.7.2; ČSN EN 12209, čl. 5.10.2; ČSN EN 15684, čl. 5.7.3, 5.7.4, 5.7.5; ČSN EN 16864, čl. 5.7.3, 5.7.4, 5.7.5; ČSN EN 14846, čl. 6.7.2.1, 6.7.2.2, 6.7.3; ČSN EN 16867+A2, čl. 6.3.3, 6.6,4, 6.6.5; ČSN EN 1300, čl. 8.2.7.2; ČSN EN 179, čl. 6.2.2 I&HAS – wszystkie czesci, ZVB (zamki o wysokim bezpieczenstwie) Badanie odpornosci na suche goraco (funkcjonalne, wytrzymalosciowe) I&HAS – vsechny casti, ZVB Zkouska odolnosti proti suchemu teplu (provozni, odolnostni) CSN EN 50130-5 ed. 2, kap. 8 a 9; CSN EN 60068-2-2; CSN EN 1125, cl. 6.2.2; CSN EN 1303, cl. 6.7.2; CSN EN 12209, cl. 5.10.2; CSN EN 15684, cl. 5.7.3, 5.7.4, 5.7.5; CSN EN 16864, cl. 5.7.3, 5.7.4, 5.7.5; CSN EN 14846, cl. 6.7.2.1, 6.7.2.2, 6.7.3; CSN EN 16867+A2, cl. 6.3.3, 6.6,4, 6.6.5; CSN EN 1300, cl. 8.2.7.2; CSN EN 179, cl. 6.2.2","search_en":"I&HAS – all components, ZVB (high security locks) Dry heat test (operational, endurance) ČSN EN 50130-5 ed. 2, kap. 8 a 9; ČSN EN 60068-2-2; ČSN EN 1125, čl. 6.2.2; ČSN EN 1303, čl. 6.7.2; ČSN EN 12209, čl. 5.10.2; ČSN EN 15684, čl. 5.7.3, 5.7.4, 5.7.5; ČSN EN 16864, čl. 5.7.3, 5.7.4, 5.7.5; ČSN EN 14846, čl. 6.7.2.1, 6.7.2.2, 6.7.3; ČSN EN 16867+A2, čl. 6.3.3, 6.6,4, 6.6.5; ČSN EN 1300, čl. 8.2.7.2; ČSN EN 179, čl. 6.2.2","search_zh":"I&HAS – 所有部件、高安全锁（ZVB） 耐干热试验（运行、耐久） ČSN EN 50130-5 ed. 2, kap. 8 a 9; ČSN EN 60068-2-2; ČSN EN 1125, čl. 6.2.2; ČSN EN 1303, čl. 6.7.2; ČSN EN 12209, čl. 5.10.2; ČSN EN 15684, čl. 5.7.3, 5.7.4, 5.7.5; ČSN EN 16864, čl. 5.7.3, 5.7.4, 5.7.5; ČSN EN 14846, čl. 6.7.2.1, 6.7.2.2, 6.7.3; ČSN EN 16867+A2, čl. 6.3.3, 6.6,4, 6.6.5; ČSN EN 1300, čl. 8.2.7.2; ČSN EN 179, čl. 6.2.2","categories":["electronics"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":17,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"a8ef04aadf4bbecd6a6200c8","lab_id":"69ad52a4de79e566650fd2b6","country":"CZ","accr_number":"1172","accr_body":"ČIA","row_label":"19","test_object":"I&HAS – wszystkie części, ZVB (zamki o wysokim bezpieczeństwie)","test_object_en":"I&HAS – all components, ZVB (high security locks)","test_object_zh":"I&HAS – 所有部件、高安全锁（ZVB）","test_object_cs":"I&HAS – všechny části, ZVB","methodology":"Badanie odporności na zimno (funkcjonalne)","methodology_en":"Cold test (operational)","methodology_zh":"耐寒试验（运行）","methodology_cs":"Zkouška odolnosti proti chladu (provozní)","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Badanie odporności na zimno (funkcjonalne)","reference":"ČSN EN 50130-5 ed. 2, kap. 10; ČSN EN 60068-2-1 ed. 2; ČSN EN 1125, čl. 6.2.2; ČSN EN 1303, čl. 6.7.2; ČSN EN 12320, čl. 5.5.8; ČSN EN 12209, čl. 5.10.2; ČSN EN 15684, čl. 5.7.4, 5.7.5; ČSN EN 16864, čl. 5.7.4, 5.7.5; ČSN EN 14846, čl. 6.7.2.1, 6.7.2.2; ČSN EN 16867+A2, čl. 6.6.4; ČSN EN 1300, čl. 8.2.7.1; ČSN EN 179, čl. 6.2.2","norm_bases":["ČSN EN 50130-5 ed. 2","ČSN EN 60068-2-1 ed. 2","ČSN EN 1125","ČSN EN 1303","ČSN EN 12320","ČSN EN 12209","ČSN EN 15684","ČSN EN 16864","ČSN EN 14846","ČSN EN 16867+A2","ČSN EN 1300","ČSN EN 179"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"I&HAS – wszystkie części, ZVB (zamki o wysokim bezpieczeństwie) Badanie odporności na zimno (funkcjonalne) I&HAS – všechny části, ZVB Zkouška odolnosti proti chladu (provozní) ČSN EN 50130-5 ed. 2, kap. 10; ČSN EN 60068-2-1 ed. 2; ČSN EN 1125, čl. 6.2.2; ČSN EN 1303, čl. 6.7.2; ČSN EN 12320, čl. 5.5.8; ČSN EN 12209, čl. 5.10.2; ČSN EN 15684, čl. 5.7.4, 5.7.5; ČSN EN 16864, čl. 5.7.4, 5.7.5; ČSN EN 14846, čl. 6.7.2.1, 6.7.2.2; ČSN EN 16867+A2, čl. 6.6.4; ČSN EN 1300, čl. 8.2.7.1; ČSN EN 179, čl. 6.2.2 I&HAS – wszystkie czesci, ZVB (zamki o wysokim bezpieczenstwie) Badanie odpornosci na zimno (funkcjonalne) I&HAS – vsechny casti, ZVB Zkouska odolnosti proti chladu (provozni) CSN EN 50130-5 ed. 2, kap. 10; CSN EN 60068-2-1 ed. 2; CSN EN 1125, cl. 6.2.2; CSN EN 1303, cl. 6.7.2; CSN EN 12320, cl. 5.5.8; CSN EN 12209, cl. 5.10.2; CSN EN 15684, cl. 5.7.4, 5.7.5; CSN EN 16864, cl. 5.7.4, 5.7.5; CSN EN 14846, cl. 6.7.2.1, 6.7.2.2; CSN EN 16867+A2, cl. 6.6.4; CSN EN 1300, cl. 8.2.7.1; CSN EN 179, cl. 6.2.2","search_en":"I&HAS – all components, ZVB (high security locks) Cold test (operational) ČSN EN 50130-5 ed. 2, kap. 10; ČSN EN 60068-2-1 ed. 2; ČSN EN 1125, čl. 6.2.2; ČSN EN 1303, čl. 6.7.2; ČSN EN 12320, čl. 5.5.8; ČSN EN 12209, čl. 5.10.2; ČSN EN 15684, čl. 5.7.4, 5.7.5; ČSN EN 16864, čl. 5.7.4, 5.7.5; ČSN EN 14846, čl. 6.7.2.1, 6.7.2.2; ČSN EN 16867+A2, čl. 6.6.4; ČSN EN 1300, čl. 8.2.7.1; ČSN EN 179, čl. 6.2.2","search_zh":"I&HAS – 所有部件、高安全锁（ZVB） 耐寒试验（运行） ČSN EN 50130-5 ed. 2, kap. 10; ČSN EN 60068-2-1 ed. 2; ČSN EN 1125, čl. 6.2.2; ČSN EN 1303, čl. 6.7.2; ČSN EN 12320, čl. 5.5.8; ČSN EN 12209, čl. 5.10.2; ČSN EN 15684, čl. 5.7.4, 5.7.5; ČSN EN 16864, čl. 5.7.4, 5.7.5; ČSN EN 14846, čl. 6.7.2.1, 6.7.2.2; ČSN EN 16867+A2, čl. 6.6.4; ČSN EN 1300, čl. 8.2.7.1; ČSN EN 179, čl. 6.2.2","categories":["electronics"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":18,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"97bab760873e2416c85663d1","lab_id":"69ad52a4de79e566650fd2b6","country":"CZ","accr_number":"1172","accr_body":"ČIA","row_label":"20","test_object":"I&HAS – wszystkie części","test_object_en":"I&HAS – all components","test_object_zh":"I&HAS – 所有部件","test_object_cs":"I&HAS – všechny části","methodology":"Badanie odporności na zmiany temperatury (funkcjonalne)","methodology_en":"Change of temperature test (operational)","methodology_zh":"温度变化试验（运行）","methodology_cs":"Zkouška odolnosti proti změnám teploty (provozní)","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Badanie odporności na zmiany temperatury (funkcjonalne)","reference":"ČSN EN 50130-5 ed. 2, kap. 11; ČSN EN IEC 60068-2-14 ed. 3","norm_bases":["ČSN EN 50130-5 ed. 2","ČSN EN IEC 60068-2-14 ed. 3"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"I&HAS – wszystkie części Badanie odporności na zmiany temperatury (funkcjonalne) I&HAS – všechny části Zkouška odolnosti proti změnám teploty (provozní) ČSN EN 50130-5 ed. 2, kap. 11; ČSN EN IEC 60068-2-14 ed. 3 I&HAS – wszystkie czesci Badanie odpornosci na zmiany temperatury (funkcjonalne) I&HAS – vsechny casti Zkouska odolnosti proti zmenam teploty (provozni) CSN EN 50130-5 ed. 2, kap. 11; CSN EN IEC 60068-2-14 ed. 3","search_en":"I&HAS – all components Change of temperature test (operational) ČSN EN 50130-5 ed. 2, kap. 11; ČSN EN IEC 60068-2-14 ed. 3","search_zh":"I&HAS – 所有部件 温度变化试验（运行） ČSN EN 50130-5 ed. 2, kap. 11; ČSN EN IEC 60068-2-14 ed. 3","categories":["electronics"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":19,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"3bba62047392f7fc38a86324","lab_id":"69ad52a4de79e566650fd2b6","country":"CZ","accr_number":"1172","accr_body":"ČIA","row_label":"21","test_object":"I&HAS – wszystkie części","test_object_en":"I&HAS – all components","test_object_zh":"I&HAS – 所有部件","test_object_cs":"I&HAS – všechny části","methodology":"Badanie odporności na wilgotne gorąco, stałe (funkcjonalne)","methodology_en":"Damp heat, steady state test (operational)","methodology_zh":"恒定湿热试验（运行）","methodology_cs":"Zkouška odolnosti proti vlhkému teplu, konstantní (provozní)","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Badanie odporności na wilgotne gorąco, stałe (funkcjonalne)","reference":"ČSN EN 50130-5 ed. 2, kap. 12; ČSN EN 60068-2-78 ed. 2","norm_bases":["ČSN EN 50130-5 ed. 2","ČSN EN 60068-2-78 ed. 2"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"I&HAS – wszystkie części Badanie odporności na wilgotne gorąco, stałe (funkcjonalne) I&HAS – všechny části Zkouška odolnosti proti vlhkému teplu, konstantní (provozní) ČSN EN 50130-5 ed. 2, kap. 12; ČSN EN 60068-2-78 ed. 2 I&HAS – wszystkie czesci Badanie odpornosci na wilgotne goraco, stale (funkcjonalne) I&HAS – vsechny casti Zkouska odolnosti proti vlhkemu teplu, konstantni (provozni) CSN EN 50130-5 ed. 2, kap. 12; CSN EN 60068-2-78 ed. 2","search_en":"I&HAS – all components Damp heat, steady state test (operational) ČSN EN 50130-5 ed. 2, kap. 12; ČSN EN 60068-2-78 ed. 2","search_zh":"I&HAS – 所有部件 恒定湿热试验（运行） ČSN EN 50130-5 ed. 2, kap. 12; ČSN EN 60068-2-78 ed. 2","categories":["electronics"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":20,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"0ceb150202eda34e7dc3ce7e","lab_id":"69ad52a4de79e566650fd2b6","country":"CZ","accr_number":"1172","accr_body":"ČIA","row_label":"22","test_object":"I&HAS – wszystkie części","test_object_en":"I&HAS – all components","test_object_zh":"I&HAS – 所有部件","test_object_cs":"I&HAS – všechny části","methodology":"Badanie odporności na wilgotne gorąco, stałe (wytrzymałościowe)","methodology_en":"Damp heat, steady state test (endurance)","methodology_zh":"恒定湿热试验（耐久）","methodology_cs":"Zkouška proti vlhkému teplu, konstantnímu (odolnostní)","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Badanie odporności na wilgotne gorąco, stałe (wytrzymałościowe)","reference":"ČSN EN 50130-5 ed. 2, kap. 13; ČSN EN 60068-2-78 ed. 2","norm_bases":["ČSN EN 50130-5 ed. 2","ČSN EN 60068-2-78 ed. 2"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"I&HAS – wszystkie części Badanie odporności na wilgotne gorąco, stałe (wytrzymałościowe) I&HAS – všechny části Zkouška proti vlhkému teplu, konstantnímu (odolnostní) ČSN EN 50130-5 ed. 2, kap. 13; ČSN EN 60068-2-78 ed. 2 I&HAS – wszystkie czesci Badanie odpornosci na wilgotne goraco, stale (wytrzymalosciowe) I&HAS – vsechny casti Zkouska proti vlhkemu teplu, konstantnimu (odolnostni) CSN EN 50130-5 ed. 2, kap. 13; CSN EN 60068-2-78 ed. 2","search_en":"I&HAS – all components Damp heat, steady state test (endurance) ČSN EN 50130-5 ed. 2, kap. 13; ČSN EN 60068-2-78 ed. 2","search_zh":"I&HAS – 所有部件 恒定湿热试验（耐久） ČSN EN 50130-5 ed. 2, kap. 13; ČSN EN 60068-2-78 ed. 2","categories":["electronics"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":21,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"fa1640bc5ed94e9a4a9e7aa8","lab_id":"69ad52a4de79e566650fd2b6","country":"CZ","accr_number":"1172","accr_body":"ČIA","row_label":"23","test_object":"I&HAS – wszystkie części, ZVB (zamki o wysokim bezpieczeństwie)","test_object_en":"I&HAS – all components, ZVB (high security locks)","test_object_zh":"I&HAS – 所有部件、高安全锁（ZVB）","test_object_cs":"I&HAS – všechny části, ZVB","methodology":"Badanie odporności na wilgotne gorąco, cykliczne (funkcjonalne)","methodology_en":"Damp heat, cyclic test (operational)","methodology_zh":"交变湿热试验（运行）","methodology_cs":"Zkouška proti vlhkému teplu, cyklické (provozní)","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Badanie odporności na wilgotne gorąco, cykliczne (funkcjonalne)","reference":"ČSN EN 50130-5 ed. 2, kap. 14; ČSN EN 60068-2-30 ed. 2; ČSN EN 15684, čl. 5.7.5; ČSN EN 16864, čl. 5.7.5; ČSN EN 14846, čl. 6.7.3; ČSN EN 16867+A2, čl. 6.6.5","norm_bases":["ČSN EN 50130-5 ed. 2","ČSN EN 60068-2-30 ed. 2","ČSN EN 15684","ČSN EN 16864","ČSN EN 14846","ČSN EN 16867+A2"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"I&HAS – wszystkie części, ZVB (zamki o wysokim bezpieczeństwie) Badanie odporności na wilgotne gorąco, cykliczne (funkcjonalne) I&HAS – všechny části, ZVB Zkouška proti vlhkému teplu, cyklické (provozní) ČSN EN 50130-5 ed. 2, kap. 14; ČSN EN 60068-2-30 ed. 2; ČSN EN 15684, čl. 5.7.5; ČSN EN 16864, čl. 5.7.5; ČSN EN 14846, čl. 6.7.3; ČSN EN 16867+A2, čl. 6.6.5 I&HAS – wszystkie czesci, ZVB (zamki o wysokim bezpieczenstwie) Badanie odpornosci na wilgotne goraco, cykliczne (funkcjonalne) I&HAS – vsechny casti, ZVB Zkouska proti vlhkemu teplu, cyklicke (provozni) CSN EN 50130-5 ed. 2, kap. 14; CSN EN 60068-2-30 ed. 2; CSN EN 15684, cl. 5.7.5; CSN EN 16864, cl. 5.7.5; CSN EN 14846, cl. 6.7.3; CSN EN 16867+A2, cl. 6.6.5","search_en":"I&HAS – all components, ZVB (high security locks) Damp heat, cyclic test (operational) ČSN EN 50130-5 ed. 2, kap. 14; ČSN EN 60068-2-30 ed. 2; ČSN EN 15684, čl. 5.7.5; ČSN EN 16864, čl. 5.7.5; ČSN EN 14846, čl. 6.7.3; ČSN EN 16867+A2, čl. 6.6.5","search_zh":"I&HAS – 所有部件、高安全锁（ZVB） 交变湿热试验（运行） ČSN EN 50130-5 ed. 2, kap. 14; ČSN EN 60068-2-30 ed. 2; ČSN EN 15684, čl. 5.7.5; ČSN EN 16864, čl. 5.7.5; ČSN EN 14846, čl. 6.7.3; ČSN EN 16867+A2, čl. 6.6.5","categories":["electronics"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":22,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"b6547693abf33b62868a448f","lab_id":"69ad52a4de79e566650fd2b6","country":"CZ","accr_number":"1172","accr_body":"ČIA","row_label":"24","test_object":"I&HAS – wszystkie części","test_object_en":"I&HAS – all components","test_object_zh":"I&HAS – 所有部件","test_object_cs":"I&HAS – všechny části","methodology":"Badanie odporności na wilgotne gorąco, cykliczne (wytrzymałościowe)","methodology_en":"Damp heat, cyclic test (endurance)","methodology_zh":"交变湿热试验（耐久）","methodology_cs":"Zkouška proti vlhkému teplu, cyklickému (odolnostní)","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Badanie odporności na wilgotne gorąco, cykliczne (wytrzymałościowe)","reference":"ČSN EN 50130-5 ed. 2, kap. 15; ČSN EN 60068-2-30 ed. 2","norm_bases":["ČSN EN 50130-5 ed. 2","ČSN EN 60068-2-30 ed. 2"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"I&HAS – wszystkie części Badanie odporności na wilgotne gorąco, cykliczne (wytrzymałościowe) I&HAS – všechny části Zkouška proti vlhkému teplu, cyklickému (odolnostní) ČSN EN 50130-5 ed. 2, kap. 15; ČSN EN 60068-2-30 ed. 2 I&HAS – wszystkie czesci Badanie odpornosci na wilgotne goraco, cykliczne (wytrzymalosciowe) I&HAS – vsechny casti Zkouska proti vlhkemu teplu, cyklickemu (odolnostni) CSN EN 50130-5 ed. 2, kap. 15; CSN EN 60068-2-30 ed. 2","search_en":"I&HAS – all components Damp heat, cyclic test (endurance) ČSN EN 50130-5 ed. 2, kap. 15; ČSN EN 60068-2-30 ed. 2","search_zh":"I&HAS – 所有部件 交变湿热试验（耐久） ČSN EN 50130-5 ed. 2, kap. 15; ČSN EN 60068-2-30 ed. 2","categories":["electronics"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":23,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"53230e1f8b93bb9a4e157025","lab_id":"69ad52a4de79e566650fd2b6","country":"CZ","accr_number":"1172","accr_body":"ČIA","row_label":"25","test_object":"I&HAS – wszystkie części","test_object_en":"I&HAS – all components","test_object_zh":"I&HAS – 所有部件","test_object_cs":"I&HAS – všechny části","methodology":"Badanie odporności na swobodny spadek (funkcjonalne)","methodology_en":"Free fall test (operational)","methodology_zh":"自由跌落试验（运行）","methodology_cs":"Zkouška odolnosti proti volnému pádu (provozní)","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Badanie odporności na swobodny spadek (funkcjonalne)","reference":"ČSN EN 50130-5 ed. 2, kap. 21; ČSN EN 60068-2-31","norm_bases":["ČSN EN 50130-5 ed. 2","ČSN EN 60068-2-31"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"I&HAS – wszystkie części Badanie odporności na swobodny spadek (funkcjonalne) I&HAS – všechny části Zkouška odolnosti proti volnému pádu (provozní) ČSN EN 50130-5 ed. 2, kap. 21; ČSN EN 60068-2-31 I&HAS – wszystkie czesci Badanie odpornosci na swobodny spadek (funkcjonalne) I&HAS – vsechny casti Zkouska odolnosti proti volnemu padu (provozni) CSN EN 50130-5 ed. 2, kap. 21; CSN EN 60068-2-31","search_en":"I&HAS – all components Free fall test (operational) ČSN EN 50130-5 ed. 2, kap. 21; ČSN EN 60068-2-31","search_zh":"I&HAS – 所有部件 自由跌落试验（运行） ČSN EN 50130-5 ed. 2, kap. 21; ČSN EN 60068-2-31","categories":["electronics"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":24,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"c0ec3d67c13f10441f70ecd1","lab_id":"69ad52a4de79e566650fd2b6","country":"CZ","accr_number":"1172","accr_body":"ČIA","row_label":"26","test_object":"I&HAS – wszystkie części","test_object_en":"I&HAS – all components","test_object_zh":"I&HAS – 所有部件","test_object_cs":"I&HAS – všechny části","methodology":"Badanie odporności na uderzenie (funkcjonalne)","methodology_en":"Impact test (operational)","methodology_zh":"冲击试验（运行）","methodology_cs":"Zkouška odolnosti proti úderu (provozní)","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Badanie odporności na uderzenie (funkcjonalne)","reference":"ČSN EN 50130-5 ed. 2, kap. 20; ČSN EN 60068-2-75 ed. 2, kap 6, 7","norm_bases":["ČSN EN 50130-5 ed. 2","ČSN EN 60068-2-75 ed. 2"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"I&HAS – wszystkie części Badanie odporności na uderzenie (funkcjonalne) I&HAS – všechny části Zkouška odolnosti proti úderu (provozní) ČSN EN 50130-5 ed. 2, kap. 20; ČSN EN 60068-2-75 ed. 2, kap 6, 7 I&HAS – wszystkie czesci Badanie odpornosci na uderzenie (funkcjonalne) I&HAS – vsechny casti Zkouska odolnosti proti uderu (provozni) CSN EN 50130-5 ed. 2, kap. 20; CSN EN 60068-2-75 ed. 2, kap 6, 7","search_en":"I&HAS – all components Impact test (operational) ČSN EN 50130-5 ed. 2, kap. 20; ČSN EN 60068-2-75 ed. 2, kap 6, 7","search_zh":"I&HAS – 所有部件 冲击试验（运行） ČSN EN 50130-5 ed. 2, kap. 20; ČSN EN 60068-2-75 ed. 2, kap 6, 7","categories":["electronics"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":25,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"1d39e48879bf8a775211f6e6","lab_id":"69ad52a4de79e566650fd2b6","country":"CZ","accr_number":"1172","accr_body":"ČIA","row_label":"27","test_object":"I&HAS – wszystkie części","test_object_en":"I&HAS – all components","test_object_zh":"I&HAS – 所有部件","test_object_cs":"I&HAS – všechny části","methodology":"Badanie odporności na krótkotrwałe zapady i zaniki napięcia zasilania sieciowego","methodology_en":"Immunity test to voltage dips and short interruptions of mains supply","methodology_zh":"电网电压暂降和短时中断抗扰度试验","methodology_cs":"Zkouška odolnosti proti krátkodobým poklesům a výpadkům síťového napájecího napětí","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Badanie odporności na krótkotrwałe zapady i zaniki napięcia zasilania sieciowego","reference":"ČSN EN 50130-4 ed. 2, kap. 8; ČSN EN 61000-4-11 ed. 2:2005; ČSN EN IEC 61000-4-11 ed. 3","norm_bases":["ČSN EN 50130-4 ed. 2","ČSN EN 61000-4-11 ed. 2:2005","ČSN EN IEC 61000-4-11 ed. 3"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"I&HAS – wszystkie części Badanie odporności na krótkotrwałe zapady i zaniki napięcia zasilania sieciowego I&HAS – všechny části Zkouška odolnosti proti krátkodobým poklesům a výpadkům síťového napájecího napětí ČSN EN 50130-4 ed. 2, kap. 8; ČSN EN 61000-4-11 ed. 2:2005; ČSN EN IEC 61000-4-11 ed. 3 I&HAS – wszystkie czesci Badanie odpornosci na krotkotrwale zapady i zaniki napiecia zasilania sieciowego I&HAS – vsechny casti Zkouska odolnosti proti kratkodobym poklesum a vypadkum sitoveho napajeciho napeti CSN EN 50130-4 ed. 2, kap. 8; CSN EN 61000-4-11 ed. 2:2005; CSN EN IEC 61000-4-11 ed. 3","search_en":"I&HAS – all components Immunity test to voltage dips and short interruptions of mains supply ČSN EN 50130-4 ed. 2, kap. 8; ČSN EN 61000-4-11 ed. 2:2005; ČSN EN IEC 61000-4-11 ed. 3","search_zh":"I&HAS – 所有部件 电网电压暂降和短时中断抗扰度试验 ČSN EN 50130-4 ed. 2, kap. 8; ČSN EN 61000-4-11 ed. 2:2005; ČSN EN IEC 61000-4-11 ed. 3","categories":["electronics"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":26,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"8108d015b6fe7ed381adeb39","lab_id":"69ad52a4de79e566650fd2b6","country":"CZ","accr_number":"1172","accr_body":"ČIA","row_label":"28","test_object":"I&HAS – wszystkie części","test_object_en":"I&HAS – all components","test_object_zh":"I&HAS – 所有部件","test_object_cs":"I&HAS – všechny části","methodology":"Badanie odporności na wyładowania elektrostatyczne","methodology_en":"Electrostatic discharge immunity test","methodology_zh":"静电放电抗扰度试验","methodology_cs":"Zkouška odolnosti proti elektrostatickým výbojům","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Badanie odporności na wyładowania elektrostatyczne","reference":"ČSN EN 50130-4 ed. 2, kap. 9; ČSN EN 61000-4-2 ed. 2","norm_bases":["ČSN EN 50130-4 ed. 2","ČSN EN 61000-4-2 ed. 2"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"I&HAS – wszystkie części Badanie odporności na wyładowania elektrostatyczne I&HAS – všechny části Zkouška odolnosti proti elektrostatickým výbojům ČSN EN 50130-4 ed. 2, kap. 9; ČSN EN 61000-4-2 ed. 2 I&HAS – wszystkie czesci Badanie odpornosci na wyladowania elektrostatyczne I&HAS – vsechny casti Zkouska odolnosti proti elektrostatickym vybojum CSN EN 50130-4 ed. 2, kap. 9; CSN EN 61000-4-2 ed. 2","search_en":"I&HAS – all components Electrostatic discharge immunity test ČSN EN 50130-4 ed. 2, kap. 9; ČSN EN 61000-4-2 ed. 2","search_zh":"I&HAS – 所有部件 静电放电抗扰度试验 ČSN EN 50130-4 ed. 2, kap. 9; ČSN EN 61000-4-2 ed. 2","categories":["electronics"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":27,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"400b4186800bbdc101fe18a0","lab_id":"69ad52a4de79e566650fd2b6","country":"CZ","accr_number":"1172","accr_body":"ČIA","row_label":"29","test_object":"I&HAS – wszystkie części","test_object_en":"I&HAS – all components","test_object_zh":"I&HAS – 所有部件","test_object_cs":"I&HAS – všechny části","methodology":"Badanie odporności na szybkie elektryczne stany przejściowe","methodology_en":"Electrical fast transient immunity test","methodology_zh":"电快速瞬变抗扰度试验","methodology_cs":"Zkouška odolnosti proti rychlým přechodovým dějům","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Badanie odporności na szybkie elektryczne stany przejściowe","reference":"ČSN EN 50130-4 ed. 2, kap. 12; ČSN EN 61000-4-4 ed. 3","norm_bases":["ČSN EN 50130-4 ed. 2","ČSN EN 61000-4-4 ed. 3"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"I&HAS – wszystkie części Badanie odporności na szybkie elektryczne stany przejściowe I&HAS – všechny části Zkouška odolnosti proti rychlým přechodovým dějům ČSN EN 50130-4 ed. 2, kap. 12; ČSN EN 61000-4-4 ed. 3 I&HAS – wszystkie czesci Badanie odpornosci na szybkie elektryczne stany przejsciowe I&HAS – vsechny casti Zkouska odolnosti proti rychlym prechodovym dejum CSN EN 50130-4 ed. 2, kap. 12; CSN EN 61000-4-4 ed. 3","search_en":"I&HAS – all components Electrical fast transient immunity test ČSN EN 50130-4 ed. 2, kap. 12; ČSN EN 61000-4-4 ed. 3","search_zh":"I&HAS – 所有部件 电快速瞬变抗扰度试验 ČSN EN 50130-4 ed. 2, kap. 12; ČSN EN 61000-4-4 ed. 3","categories":["electronics"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":28,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"1136394e46aee9a7d3e6d084","lab_id":"69ad52a4de79e566650fd2b6","country":"CZ","accr_number":"1172","accr_body":"ČIA","row_label":"30","test_object":"I&HAS – wszystkie części","test_object_en":"I&HAS – all components","test_object_zh":"I&HAS – 所有部件","test_object_cs":"I&HAS – všechny části","methodology":"Badanie działania przy zmianach napięcia zasilania sieciowego","methodology_en":"Function test under mains supply voltage variations","methodology_zh":"电网供电电压变化下的功能试验","methodology_cs":"Zkouška funkce při změnách síťového napájecího napětí","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Badanie działania przy zmianach napięcia zasilania sieciowego","reference":"ČSN EN 50130-4 ed. 2, kap. 7","norm_bases":["ČSN EN 50130-4 ed. 2"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"I&HAS – wszystkie części Badanie działania przy zmianach napięcia zasilania sieciowego I&HAS – všechny části Zkouška funkce při změnách síťového napájecího napětí ČSN EN 50130-4 ed. 2, kap. 7 I&HAS – wszystkie czesci Badanie dzialania przy zmianach napiecia zasilania sieciowego I&HAS – vsechny casti Zkouska funkce pri zmenach sitoveho napajeciho napeti CSN EN 50130-4 ed. 2, kap. 7","search_en":"I&HAS – all components Function test under mains supply voltage variations ČSN EN 50130-4 ed. 2, kap. 7","search_zh":"I&HAS – 所有部件 电网供电电压变化下的功能试验 ČSN EN 50130-4 ed. 2, kap. 7","categories":["electronics"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":29,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"ce54b3d6363116ba053b8187","lab_id":"69ad52a4de79e566650fd2b6","country":"CZ","accr_number":"1172","accr_body":"ČIA","row_label":"31","test_object":"I&HAS – wszystkie części","test_object_en":"I&HAS – all components","test_object_zh":"I&HAS – 所有部件","test_object_cs":"I&HAS – všechny části","methodology":"Badanie odporności na udary","methodology_en":"Surge immunity test","methodology_zh":"浪涌抗扰度试验","methodology_cs":"Zkouška odolnosti proti rázovým impulsům","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Badanie odporności na udary","reference":"ČSN EN 50130-4 ed. 2, kap. 13; ČSN EN 61000-4-5 ed. 3","norm_bases":["ČSN EN 50130-4 ed. 2","ČSN EN 61000-4-5 ed. 3"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"I&HAS – wszystkie części Badanie odporności na udary I&HAS – všechny části Zkouška odolnosti proti rázovým impulsům ČSN EN 50130-4 ed. 2, kap. 13; ČSN EN 61000-4-5 ed. 3 I&HAS – wszystkie czesci Badanie odpornosci na udary I&HAS – vsechny casti Zkouska odolnosti proti razovym impulsum CSN EN 50130-4 ed. 2, kap. 13; CSN EN 61000-4-5 ed. 3","search_en":"I&HAS – all components Surge immunity test ČSN EN 50130-4 ed. 2, kap. 13; ČSN EN 61000-4-5 ed. 3","search_zh":"I&HAS – 所有部件 浪涌抗扰度试验 ČSN EN 50130-4 ed. 2, kap. 13; ČSN EN 61000-4-5 ed. 3","categories":["electronics"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":30,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"412d0552ca4323173463ade3","lab_id":"69ad52a4de79e566650fd2b6","country":"CZ","accr_number":"1172","accr_body":"ČIA","row_label":"32","test_object":"I&HAS – wszystkie części","test_object_en":"I&HAS – all components","test_object_zh":"I&HAS – 所有部件","test_object_cs":"I&HAS – všechny části","methodology":"Pomiar napięcia zaburzeń na wejściach/wyjściach sieciowych i telekomunikacyjnych","methodology_en":"Measurement of conducted disturbance voltage at mains and telecommunication ports","methodology_zh":"电源和电信端口骚扰电压测量","methodology_cs":"Měření rušivého napětí na síťových a telekomunikačních vstupech/výstupech","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pomiar napięcia zaburzeń na wejściach/wyjściach sieciowych i telekomunikacyjnych","reference":"ČSN EN 55032 ed. 2, kap. 6; ČSN EN IEC 61000-6-3 ed. 3","norm_bases":["ČSN EN 55032 ed. 2","ČSN EN IEC 61000-6-3 ed. 3"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"I&HAS – wszystkie części Pomiar napięcia zaburzeń na wejściach/wyjściach sieciowych i telekomunikacyjnych I&HAS – všechny části Měření rušivého napětí na síťových a telekomunikačních vstupech/výstupech ČSN EN 55032 ed. 2, kap. 6; ČSN EN IEC 61000-6-3 ed. 3 I&HAS – wszystkie czesci Pomiar napiecia zaburzen na wejsciach/wyjsciach sieciowych i telekomunikacyjnych I&HAS – vsechny casti Mereni rusiveho napeti na sitovych a telekomunikacnich vstupech/vystupech CSN EN 55032 ed. 2, kap. 6; CSN EN IEC 61000-6-3 ed. 3","search_en":"I&HAS – all components Measurement of conducted disturbance voltage at mains and telecommunication ports ČSN EN 55032 ed. 2, kap. 6; ČSN EN IEC 61000-6-3 ed. 3","search_zh":"I&HAS – 所有部件 电源和电信端口骚扰电压测量 ČSN EN 55032 ed. 2, kap. 6; ČSN EN IEC 61000-6-3 ed. 3","categories":["electronics"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":31,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"9b2a4b3480084a5d350dea17","lab_id":"69ad52a4de79e566650fd2b6","country":"CZ","accr_number":"1172","accr_body":"ČIA","row_label":"33","test_object":"I&HAS – wszystkie części","test_object_en":"I&HAS – all components","test_object_zh":"I&HAS – 所有部件","test_object_cs":"I&HAS – všechny části","methodology":"Pomiar pola zaburzeń (emisja promieniowana)","methodology_en":"Measurement of radiated disturbance field","methodology_zh":"辐射骚扰场强测量","methodology_cs":"Měření rušivého pole","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pomiar pola zaburzeń (emisja promieniowana)","reference":"ČSN EN 55032 ed. 2, kap. 6; ČSN EN IEC 61000-6-3 ed. 3","norm_bases":["ČSN EN 55032 ed. 2","ČSN EN IEC 61000-6-3 ed. 3"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"I&HAS – wszystkie części Pomiar pola zaburzeń (emisja promieniowana) I&HAS – všechny části Měření rušivého pole ČSN EN 55032 ed. 2, kap. 6; ČSN EN IEC 61000-6-3 ed. 3 I&HAS – wszystkie czesci Pomiar pola zaburzen (emisja promieniowana) I&HAS – vsechny casti Mereni rusiveho pole CSN EN 55032 ed. 2, kap. 6; CSN EN IEC 61000-6-3 ed. 3","search_en":"I&HAS – all components Measurement of radiated disturbance field ČSN EN 55032 ed. 2, kap. 6; ČSN EN IEC 61000-6-3 ed. 3","search_zh":"I&HAS – 所有部件 辐射骚扰场强测量 ČSN EN 55032 ed. 2, kap. 6; ČSN EN IEC 61000-6-3 ed. 3","categories":["electronics"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":32,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"fd0df0595bce0fdbbd850490","lab_id":"69ad52a4de79e566650fd2b6","country":"CZ","accr_number":"1172","accr_body":"ČIA","row_label":"34","test_object":"I&HAS – wszystkie części","test_object_en":"I&HAS – all components","test_object_zh":"I&HAS – 所有部件","test_object_cs":"I&HAS – všechny části","methodology":"Badanie odporności na zaburzenia indukowane polami elektromagnetycznymi wielkiej częstotliwości","methodology_en":"Immunity test to disturbances induced by radio-frequency electromagnetic fields","methodology_zh":"射频电磁场感应传导骚扰抗扰度试验","methodology_cs":"Zkouška rušení indukované vysokofrekvenčními elektromagnetickými poli","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Badanie odporności na zaburzenia indukowane polami elektromagnetycznymi wielkiej częstotliwości","reference":"ČSN EN 50130-4 ed. 2, kap. 11; ČSN EN IEC 61000-4-6 ed. 5","norm_bases":["ČSN EN 50130-4 ed. 2","ČSN EN IEC 61000-4-6 ed. 5"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"I&HAS – wszystkie części Badanie odporności na zaburzenia indukowane polami elektromagnetycznymi wielkiej częstotliwości I&HAS – všechny části Zkouška rušení indukované vysokofrekvenčními elektromagnetickými poli ČSN EN 50130-4 ed. 2, kap. 11; ČSN EN IEC 61000-4-6 ed. 5 I&HAS – wszystkie czesci Badanie odpornosci na zaburzenia indukowane polami elektromagnetycznymi wielkiej czestotliwosci I&HAS – vsechny casti Zkouska ruseni indukovane vysokofrekvencnimi elektromagnetickymi poli CSN EN 50130-4 ed. 2, kap. 11; CSN EN IEC 61000-4-6 ed. 5","search_en":"I&HAS – all components Immunity test to disturbances induced by radio-frequency electromagnetic fields ČSN EN 50130-4 ed. 2, kap. 11; ČSN EN IEC 61000-4-6 ed. 5","search_zh":"I&HAS – 所有部件 射频电磁场感应传导骚扰抗扰度试验 ČSN EN 50130-4 ed. 2, kap. 11; ČSN EN IEC 61000-4-6 ed. 5","categories":["electronics"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":33,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"b06aaf6340efc1db9c893471","lab_id":"69ad52a4de79e566650fd2b6","country":"CZ","accr_number":"1172","accr_body":"ČIA","row_label":"35","test_object":"I&HAS – systemy ochrony obwodowej","test_object_en":"I&HAS – perimeter systems","test_object_zh":"I&HAS – 周界系统","test_object_cs":"I&HAS – perimetrické systémy","methodology":"Badanie właściwości i parametrów zewnętrznych obwodowych systemów zabezpieczeń","methodology_en":"Test of properties and parameters of external perimeter security systems","methodology_zh":"外部周界安防系统性能和参数试验","methodology_cs":"Zkouška vlastností a parametrů vnějších perimetrů zabezpečovacích systémů","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Badanie właściwości i parametrów zewnętrznych obwodowych systemów zabezpieczeń","reference":"ČSN CLC/TS 50661-1","norm_bases":["ČSN CLC/TS 50661-1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"I&HAS – systemy ochrony obwodowej Badanie właściwości i parametrów zewnętrznych obwodowych systemów zabezpieczeń I&HAS – perimetrické systémy Zkouška vlastností a parametrů vnějších perimetrů zabezpečovacích systémů ČSN CLC/TS 50661-1 I&HAS – systemy ochrony obwodowej Badanie wlasciwosci i parametrow zewnetrznych obwodowych systemow zabezpieczen I&HAS – perimetricke systemy Zkouska vlastnosti a parametru vnejsich perimetru zabezpecovacich systemu CSN CLC/TS 50661-1","search_en":"I&HAS – perimeter systems Test of properties and parameters of external perimeter security systems ČSN CLC/TS 50661-1","search_zh":"I&HAS – 周界系统 外部周界安防系统性能和参数试验 ČSN CLC/TS 50661-1","categories":["electronics"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":34,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"67916f2ad53b2f4fa725b77a","lab_id":"69ad52a4de79e566650fd2b6","country":"CZ","accr_number":"1172","accr_body":"ČIA","row_label":"36","test_object":"I&HAS – wszystkie części","test_object_en":"I&HAS – all components","test_object_zh":"I&HAS – 所有部件","test_object_cs":"I&HAS – všechny části","methodology":"Badanie kompatybilności systemowej urządzeń znajdujących się w obiektach chronionych","methodology_en":"System compatibility test of equipment located in supervised premises","methodology_zh":"受保护场所内设备系统兼容性试验","methodology_cs":"Zkouška systémové kompatibility zařízení nacházejících se ve střežených prostorech","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Badanie kompatybilności systemowej urządzeń znajdujących się w obiektach chronionych","reference":"ČSN CLC/TS 50131-5-4; ČSN CLC/TS 50131-5-1","norm_bases":["ČSN CLC/TS 50131-5-4","ČSN CLC/TS 50131-5-1"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"I&HAS – wszystkie części Badanie kompatybilności systemowej urządzeń znajdujących się w obiektach chronionych I&HAS – všechny části Zkouška systémové kompatibility zařízení nacházejících se ve střežených prostorech ČSN CLC/TS 50131-5-4; ČSN CLC/TS 50131-5-1 I&HAS – wszystkie czesci Badanie kompatybilnosci systemowej urzadzen znajdujacych sie w obiektach chronionych I&HAS – vsechny casti Zkouska systemove kompatibility zarizeni nachazejicich se ve strezenych prostorech CSN CLC/TS 50131-5-4; CSN CLC/TS 50131-5-1","search_en":"I&HAS – all components System compatibility test of equipment located in supervised premises ČSN CLC/TS 50131-5-4; ČSN CLC/TS 50131-5-1","search_zh":"I&HAS – 所有部件 受保护场所内设备系统兼容性试验 ČSN CLC/TS 50131-5-4; ČSN CLC/TS 50131-5-1","categories":["electronics"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":35,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"4e6773d0a980ac4b74fa9aef","lab_id":"69ad52a4de79e566650fd2b6","country":"CZ","accr_number":"1172","accr_body":"ČIA","row_label":"37","test_object":"I&HAS – wszystkie części","test_object_en":"I&HAS – all components","test_object_zh":"I&HAS – 所有部件","test_object_cs":"I&HAS – všechny části","methodology":"Kontrola właściwego oznakowania i dokumentacji towarzyszącej wyrobu","methodology_en":"Check of appropriate marking and accompanying product documentation","methodology_zh":"产品标识及随附文件检查","methodology_cs":"Kontrola odpovídajícího značení a průvodní dokumentace výrobku","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Kontrola właściwego oznakowania i dokumentacji towarzyszącej wyrobu","reference":"ČSN EN 50131-1 ed. 2, kap. 14 a 15","norm_bases":["ČSN EN 50131-1 ed. 2"],"lab_section":null,"lab_section_en":null,"lab_section_zh":null,"lab_section_cs":null,"lab_address":null,"regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"I&HAS – wszystkie części Kontrola właściwego oznakowania i dokumentacji towarzyszącej wyrobu I&HAS – všechny části Kontrola odpovídajícího značení a průvodní dokumentace výrobku ČSN EN 50131-1 ed. 2, kap. 14 a 15 I&HAS – wszystkie czesci Kontrola wlasciwego oznakowania i dokumentacji towarzyszacej wyrobu I&HAS – vsechny casti Kontrola odpovidajiciho znaceni a pruvodni dokumentace vyrobku CSN EN 50131-1 ed. 2, kap. 14 a 15","search_en":"I&HAS – all components Check of appropriate marking and accompanying product documentation ČSN EN 50131-1 ed. 2, kap. 14 a 15","search_zh":"I&HAS – 所有部件 产品标识及随附文件检查 ČSN EN 50131-1 ed. 2, kap. 14 a 15","categories":["electronics"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":36,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"}],"has_pdf":true}