🇨🇿 Foster Bohemia s.r.o. PL

ČIA 1150 • 100 00 Praha 10, Czech Republic • 8 methods

EnvironmentConstruction

Foster Bohemia s.r.o. is a laboratory accredited by ČIA under number 1150 (100 00 Praha 10, Czech Republic). Its accreditation scope covers 8 test methods in the following areas: Environment, Construction. Test objects include: Building, inorganic and organic materials, dust accumulations, Outdoor and indoor air, working environment, Building and other materials, Outdoor, indoor and working air, exposed filters. Most frequently used techniques: SEM method with EDAX analyzer, Gravimetric method, Manual method.

At a glance

  • Accreditation number: ČIA 1150
  • Methods in scope: 8
  • Types of test objects: 5
  • Techniques used: 6
  • City: 100 00 Praha 10, Czech Republic
  • Valid until: 05-05-2030
Accreditation number
1150
Accreditation body
ČIA
Address
Krátká 1148/32, Strašnice, 100 00 Praha 10
City
100 00 Praha 10, Czech Republic
Division
Laboratorium Pomiarów Imisji
Valid until
05-05-2030

What this laboratory tests (5)

Analytical techniques used (6)

Certificate information

Certificate date
05.05.2025

Accreditation scope — test methods (8)

No. Test object Methodology / Parameters Technique Reference document
Test methods
1 Outdoor, indoor and working air, exposed filters Determination of numerical concentration and identification of respirable inorganic fibrous particles
Numerical concentration Identification
Regulated area: Tests
SEM method with EDAX analyzer SOP 01 (ČSN EN ISO 16000-7; směrnice VDI 3492, mimo kap. 5, 6; ISO 14966)
2 Building, inorganic and organic materials, dust accumulations Determination of presence of inorganic fibres
Regulated area: Tests
SEM method with EDAX analyzer SOP 04 (Směrnice VDI 3866, část 5)
3 Building, inorganic and organic materials, dust accumulations Determination of presence of inorganic fibres
Regulated area: Tests
Polarized Light Microscopy - PLM SOP 05 (Směrnice VDI 3866, část 4)
4 Outdoor and indoor air, working environment Determination of environmental parameters
Air temperature Relative humidity of air Atmospheric pressure
Regulated area: Tests
PZ 01 (ČSN EN ISO 7726)
5 Building and other materials Determination of the weight of materials
Regulated area: Tests
Gravimetric method PZ 02 (Uživatelský manuál použitého zařízení)
6 Working and non-working environment Determination of air pressure difference (level of tightness of a protected space)
Regulated area: Tests
Pressure gauge measurement PZ 03 (Uživatelský manuál použitého zařízení)
7 Outdoor and indoor air, working environment Stationary sampling for the determination of inorganic fibrous particles
Regulated area: Sampling
Manual method using a measuring filter SOP 02 (ČSN EN ISO 16000-1; ČSN EN ISO 16000-7; ČSN EN 482; ČSN EN 689+AC; NV č. 361/2007 Sb.; směrnice VDI 3492, kap. 5, 6; VDI 4280, část 1; ISO 14966)
8 Building, inorganic and organic materials, dust accumulations Sampling for the determination of inorganic fibrous particles
Regulated area: Sampling
Manual method SOP 03 (Směrnice VDI 3866, část 1, kap. 1-4)

Reference standards (22)

ISO 14966
NV č. 361/2007 Sb.
PZ 01
PZ 02
PZ 03
SOP 01
SOP 02
SOP 03
SOP 04
SOP 05
Směrnice VDI 3866, část 1, kap. 1-4
Směrnice VDI 3866, část 4
Směrnice VDI 3866, část 5
Uživatelský manuál použitého zařízení
VDI 4280, část 1
směrnice VDI 3492, kap. 5, 6
směrnice VDI 3492, mimo kap. 5, 6
ČSN EN 482
ČSN EN 689+AC
ČSN EN ISO 16000-1
ČSN EN ISO 16000-7
ČSN EN ISO 7726

The same scope as data (JSON): https://labcoda.pl/api/accreditation-scopes/labs/CZ/1150