🇨🇿 Skanska Transbeton, s.r.o. PL

ČIA 1122 • Praha 9 - Letňany, Czech Republic • 18 methods

Construction

Skanska Transbeton, s.r.o. is a laboratory accredited by ČIA under number 1122 (Praha 9 - Letňany, Czech Republic). Its accreditation scope covers 18 test methods in the following areas: Construction. Test objects include: Hardened concrete, Fresh concrete, Aggregate. Most frequently used techniques: Manual, Pressure gauge method, Sieving method.

At a glance

  • Accreditation number: ČIA 1122
  • Methods in scope: 18
  • Types of test objects: 3
  • Techniques used: 3
  • City: Praha 9 - Letňany, Czech Republic
  • Valid until: 14-05-2029
Accreditation number
1122
Accreditation body
ČIA
Address
Toužimská 664, 199 00 Praha 9 - Letňany
City
Praha 9 - Letňany, Czech Republic
Division
Laboratorium Badawcze
Valid until
14-05-2029

What this laboratory tests (3)

Analytical techniques used (3)

Laboratory sections (2)

Laboratory locations

Certificate information

Certificate date
14.05.2024

Accreditation scope — test methods (18)

No. Test object Methodology / Parameters Technique Reference document
Testing Laboratory - Letňany
1 Fresh concrete Slump test
Regulated area: Tests
ČSN EN 12350-2
2 Fresh concrete Determination of air content
Regulated area: Tests
Pressure gauge method ČSN EN 12350-7, čl. 6
3 Hardened concrete Determination of compressive strength of test specimens
Regulated area: Tests
ČSN EN 12390-3
4 Hardened concrete Determination of density
Regulated area: Tests
ČSN EN 12390-7, čl. 6.1.2 c)
5 Hardened concrete Determination of depth of penetration of water under pressure
Regulated area: Tests
ČSN EN 12390-8
6 Hardened concrete Determination of resistance of cement concrete surface to water and chemical de-icing agents
Regulated area: Tests
ČSN 73 1326, metoda A, čl. 13-23
7 Aggregate Determination of particle size distribution
Regulated area: Tests
Sieving method ČSN EN 933-1
8 Fresh concrete Sampling of fresh concrete
Regulated area: Sampling
Manual ČSN EN 12350-1
9 Aggregate Sampling and reducing of aggregate samples
Regulated area: Sampling
Manual ČSN EN 932-1; ČSN EN 932-2
Testing Laboratory - Olomouc
10 Fresh concrete Slump test
Regulated area: Tests
ČSN EN 12350-2
11 Fresh concrete Determination of air content
Regulated area: Tests
Pressure gauge method ČSN EN 12350-7, čl. 6
12 Hardened concrete Determination of compressive strength of test specimens
Regulated area: Tests
ČSN EN 12390-3
13 Hardened concrete Determination of density
Regulated area: Tests
ČSN EN 12390-7, čl. 6.1.2 c)
14 Hardened concrete Determination of depth of penetration of water under pressure
Regulated area: Tests
ČSN EN 12390-8
15 Hardened concrete Determination of resistance of cement concrete surface to water and chemical de-icing agents
Regulated area: Tests
ČSN 73 1326, metoda A, čl. 13-23
16 Aggregate Determination of particle size distribution
Regulated area: Tests
Sieving method ČSN EN 933-1
17 Fresh concrete Sampling of fresh concrete
Regulated area: Sampling
Manual ČSN EN 12350-1
18 Aggregate Sampling and reducing of aggregate samples
Regulated area: Sampling
Manual ČSN EN 932-1; ČSN EN 932-2

Reference standards (10)

ČSN 73 1326, metoda A, čl. 13-23
ČSN EN 12350-1
ČSN EN 12350-2
ČSN EN 12350-7, čl. 6
ČSN EN 12390-3
ČSN EN 12390-7, čl. 6.1.2 c)
ČSN EN 12390-8
ČSN EN 932-1
ČSN EN 932-2
ČSN EN 933-1

The same scope as data (JSON): https://labcoda.pl/api/accreditation-scopes/labs/CZ/1122