{"lab":{"_id":"69ad52a4de79e566650fd276","country":"CZ","accr_number":"1122","accr_body":"ČIA","address":"Toužimská 664, 199 00 Praha 9 - Letňany","categories":["construction"],"city":"Praha 9 - Letňany","imported_at":"2026-03-08T10:42:44.590Z","methods_count":18,"name":"Skanska Transbeton, s.r.o.","parse_status":"parsed","parse_version":5,"pdf_files":["1122_223_2024_CS.pdf","1122_223_2024_EN.pdf"],"scope_summary":"Badania i pobieranie próbek mieszanki betonowej, betonu stwardniałego i kruszywa.","search_text":"skanska transbeton, s.r.o. toužimská 664, 199 00 praha 9 - letňany 1122","status":"active","updated_at":"2026-03-08T14:52:06.562Z","valid_from":"","valid_until":"14-05-2029","website":"www.skanska.cz/transbeton","location":{"type":"Point","coordinates":[14.4378,50.0755]},"email_confidence":"high","email_mx":true,"email_source":"https://www.skanska.cz/transbeton","map_coord":[50.138614,14.52491],"map_geo":"nominatim-street","certificate_date":"14.05.2024","certificate_no":"223/2024","certificate_replaces":"","en_official":false,"fields_of_testing":[{"codes":"","pl":"Badania i pobieranie próbek mieszanki betonowej, betonu stwardniałego i kruszywa.","en":"Testing and sampling of fresh and hardened concrete and aggregate.","zh":"新拌和硬化混凝土及集料的检测和采样。","cs":"Zkoušky a vzorkování čerstvého a ztvrdlého betonu a kameniva."}],"flexible_scope":false,"flexible_scope_url":null,"has_en":true,"has_zh":true,"lab_division":"Laboratorium Badawcze","lab_division_cs":"Zkušební laboratoř","lab_division_en":"Testing Laboratory","lab_division_zh":"检测实验室","lab_locations":[{"code":null,"name":"Skanska Transbeton, s.r.o.","street":"Toužimská 664","postal_code":"199 00","city":"Praha 9 - Letňany","is_hq":true,"address":"Toužimská 664, 199 00 Praha 9 - Letňany","site":"19900|toužimská664"},{"code":null,"name":"Laboratorium Badawcze - Letňany","street":"Toužimská 664","postal_code":"199 00","city":"Praha 9 - Letňany","is_hq":false,"address":"Toužimská 664, 199 00 Praha 9 - Letňany","site":"19900|toužimská664"},{"code":null,"name":"Laboratorium Badawcze - Ołomuniec","street":"Pavelkova 8/1177","postal_code":"779 00","city":"Olomouc","is_hq":false,"address":"Pavelkova 8/1177, 779 00 Olomouc","site":"77900|pavelkova8/1177"}],"lab_locations_en":[{"code":null,"name":"Skanska Transbeton, s.r.o.","street":"Toužimská 664","postal_code":"199 00","city":"Praha 9 - Letňany","is_hq":true,"address":"Toužimská 664, 199 00 Praha 9 - Letňany","site":"19900|toužimská664"},{"code":null,"name":"Testing Laboratory - Letňany","street":"Toužimská 664","postal_code":"199 00","city":"Praha 9 - Letňany","is_hq":false,"address":"Toužimská 664, 199 00 Praha 9 - Letňany","site":"19900|toužimská664"},{"code":null,"name":"Testing Laboratory - Olomouc","street":"Pavelkova 8/1177","postal_code":"779 00","city":"Olomouc","is_hq":false,"address":"Pavelkova 8/1177, 779 00 Olomouc","site":"77900|pavelkova8/1177"}],"lab_locations_zh":[{"code":null,"name":"Skanska Transbeton, s.r.o.","street":"Toužimská 664","postal_code":"199 00","city":"Praha 9 - Letňany","is_hq":true,"address":"Toužimská 664, 199 00 Praha 9 - Letňany","site":"19900|toužimská664"},{"code":null,"name":"检测实验室 - 莱特尼亚尼","street":"Toužimská 664","postal_code":"199 00","city":"Praha 9 - Letňany","is_hq":false,"address":"Toužimská 664, 199 00 Praha 9 - Letňany","site":"19900|toužimská664"},{"code":null,"name":"检测实验室 - 奥洛穆茨","street":"Pavelkova 8/1177","postal_code":"779 00","city":"Olomouc","is_hq":false,"address":"Pavelkova 8/1177, 779 00 Olomouc","site":"77900|pavelkova8/1177"}],"parse_date":"2026-09-28T12:00:00.000Z","parse_source":"reczna-analiza-labcoda-3","parsed_at":"2026-09-28T12:00:00.000Z","scope_legend":[],"scope_notes":[],"source_lang":"cs","source_pdf_sha256":"b382d6c4414fcd0ec1a204d18b1bb8864a7ae1dccebf90d3124d18b959c5f659","source_pdf_url":"https://www.cai.cz/OA/pdf/P223_2024_CS.pdf","source_pdf_url_en":null},"methods":[{"_id":"7fe76874f3119086b1e11e62","lab_id":"69ad52a4de79e566650fd276","country":"CZ","accr_number":"1122","accr_body":"ČIA","row_label":"1","test_object":"Mieszanka betonowa (beton świeży)","test_object_en":"Fresh concrete","test_object_zh":"新拌混凝土","test_object_cs":"Čerstvý beton","methodology":"Badanie konsystencji metodą opadu stożka","methodology_en":"Slump test","methodology_zh":"坍落度试验","methodology_cs":"Zkouška sednutím","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Badanie konsystencji metodą opadu stożka","reference":"ČSN EN 12350-2","norm_bases":["ČSN EN 12350-2"],"lab_section":"Laboratorium Badawcze - Letňany","lab_section_en":"Testing Laboratory - Letňany","lab_section_zh":"检测实验室 - 莱特尼亚尼","lab_section_cs":"Zkušební laboratoř - Letňany","lab_address":"Toužimská 664, 199 00 Praha 9 - Letňany","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Mieszanka betonowa (beton świeży) Badanie konsystencji metodą opadu stożka Čerstvý beton Zkouška sednutím ČSN EN 12350-2 Mieszanka betonowa (beton swiezy) Badanie konsystencji metoda opadu stozka Cerstvy beton Zkouska sednutim CSN EN 12350-2","search_en":"Fresh concrete Slump test ČSN EN 12350-2","search_zh":"新拌混凝土 坍落度试验 ČSN EN 12350-2","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":0,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"8d30419f50dc5447151c7de2","lab_id":"69ad52a4de79e566650fd276","country":"CZ","accr_number":"1122","accr_body":"ČIA","row_label":"1","test_object":"Mieszanka betonowa (beton świeży)","test_object_en":"Fresh concrete","test_object_zh":"新拌混凝土","test_object_cs":"Čerstvý beton","methodology":"Badanie konsystencji metodą opadu stożka","methodology_en":"Slump test","methodology_zh":"坍落度试验","methodology_cs":"Zkouška sednutím","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Badanie konsystencji metodą opadu stożka","reference":"ČSN EN 12350-2","norm_bases":["ČSN EN 12350-2"],"lab_section":"Laboratorium Badawcze - Ołomuniec","lab_section_en":"Testing Laboratory - Olomouc","lab_section_zh":"检测实验室 - 奥洛穆茨","lab_section_cs":"Zkušební laboratoř - Olomouc","lab_address":"Pavelkova 8/1177, 779 00 Olomouc","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Mieszanka betonowa (beton świeży) Badanie konsystencji metodą opadu stożka Čerstvý beton Zkouška sednutím ČSN EN 12350-2 Mieszanka betonowa (beton swiezy) Badanie konsystencji metoda opadu stozka Cerstvy beton Zkouska sednutim CSN EN 12350-2","search_en":"Fresh concrete Slump test ČSN EN 12350-2","search_zh":"新拌混凝土 坍落度试验 ČSN EN 12350-2","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":1,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"d396b672cb1760d4ec0eea89","lab_id":"69ad52a4de79e566650fd276","country":"CZ","accr_number":"1122","accr_body":"ČIA","row_label":"2","test_object":"Mieszanka betonowa (beton świeży)","test_object_en":"Fresh concrete","test_object_zh":"新拌混凝土","test_object_cs":"Čerstvý beton","methodology":"Oznaczanie zawartości powietrza","methodology_en":"Determination of air content","methodology_zh":"含气量测定","methodology_cs":"Stanovení obsahu vzduchu","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"Metoda ciśnieniowa","technique_en":"Pressure gauge method","technique_zh":"压力法","technique_cs":"tlaková metoda","techniques":["Metoda ciśnieniowa"],"techniques_en":["Pressure gauge method"],"techniques_zh":["压力法"],"techniques_cs":["tlaková metoda"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości powietrza\nMetoda ciśnieniowa","reference":"ČSN EN 12350-7, čl. 6","norm_bases":["ČSN EN 12350-7, čl. 6"],"lab_section":"Laboratorium Badawcze - Letňany","lab_section_en":"Testing Laboratory - Letňany","lab_section_zh":"检测实验室 - 莱特尼亚尼","lab_section_cs":"Zkušební laboratoř - Letňany","lab_address":"Toužimská 664, 199 00 Praha 9 - Letňany","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Mieszanka betonowa (beton świeży) Oznaczanie zawartości powietrza Metoda ciśnieniowa Čerstvý beton Stanovení obsahu vzduchu tlaková metoda ČSN EN 12350-7, čl. 6 Mieszanka betonowa (beton swiezy) Oznaczanie zawartosci powietrza Metoda cisnieniowa Cerstvy beton Stanoveni obsahu vzduchu tlakova metoda CSN EN 12350-7, cl. 6","search_en":"Fresh concrete Determination of air content Pressure gauge method ČSN EN 12350-7, čl. 6","search_zh":"新拌混凝土 含气量测定 压力法 ČSN EN 12350-7, čl. 6","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":2,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"56925322e5467a6f4ac35f65","lab_id":"69ad52a4de79e566650fd276","country":"CZ","accr_number":"1122","accr_body":"ČIA","row_label":"2","test_object":"Mieszanka betonowa (beton świeży)","test_object_en":"Fresh concrete","test_object_zh":"新拌混凝土","test_object_cs":"Čerstvý beton","methodology":"Oznaczanie zawartości powietrza","methodology_en":"Determination of air content","methodology_zh":"含气量测定","methodology_cs":"Stanovení obsahu vzduchu","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"Metoda ciśnieniowa","technique_en":"Pressure gauge method","technique_zh":"压力法","technique_cs":"tlaková metoda","techniques":["Metoda ciśnieniowa"],"techniques_en":["Pressure gauge method"],"techniques_zh":["压力法"],"techniques_cs":["tlaková metoda"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie zawartości powietrza\nMetoda ciśnieniowa","reference":"ČSN EN 12350-7, čl. 6","norm_bases":["ČSN EN 12350-7, čl. 6"],"lab_section":"Laboratorium Badawcze - Ołomuniec","lab_section_en":"Testing Laboratory - Olomouc","lab_section_zh":"检测实验室 - 奥洛穆茨","lab_section_cs":"Zkušební laboratoř - Olomouc","lab_address":"Pavelkova 8/1177, 779 00 Olomouc","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":true,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Mieszanka betonowa (beton świeży) Oznaczanie zawartości powietrza Metoda ciśnieniowa Čerstvý beton Stanovení obsahu vzduchu tlaková metoda ČSN EN 12350-7, čl. 6 Mieszanka betonowa (beton swiezy) Oznaczanie zawartosci powietrza Metoda cisnieniowa Cerstvy beton Stanoveni obsahu vzduchu tlakova metoda CSN EN 12350-7, cl. 6","search_en":"Fresh concrete Determination of air content Pressure gauge method ČSN EN 12350-7, čl. 6","search_zh":"新拌混凝土 含气量测定 压力法 ČSN EN 12350-7, čl. 6","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":3,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"7276a0511b3e099be14f2989","lab_id":"69ad52a4de79e566650fd276","country":"CZ","accr_number":"1122","accr_body":"ČIA","row_label":"3","test_object":"Beton stwardniały","test_object_en":"Hardened concrete","test_object_zh":"硬化混凝土","test_object_cs":"Ztvrdlý beton","methodology":"Oznaczanie wytrzymałości na ściskanie próbek do badań","methodology_en":"Determination of compressive strength of test specimens","methodology_zh":"试件抗压强度测定","methodology_cs":"Stanovení pevnosti v tlaku zkušebních těles","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie wytrzymałości na ściskanie próbek do badań","reference":"ČSN EN 12390-3","norm_bases":["ČSN EN 12390-3"],"lab_section":"Laboratorium Badawcze - Letňany","lab_section_en":"Testing Laboratory - Letňany","lab_section_zh":"检测实验室 - 莱特尼亚尼","lab_section_cs":"Zkušební laboratoř - Letňany","lab_address":"Toužimská 664, 199 00 Praha 9 - Letňany","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Beton stwardniały Oznaczanie wytrzymałości na ściskanie próbek do badań Ztvrdlý beton Stanovení pevnosti v tlaku zkušebních těles ČSN EN 12390-3 Beton stwardnialy Oznaczanie wytrzymalosci na sciskanie probek do badan Ztvrdly beton Stanoveni pevnosti v tlaku zkusebnich teles CSN EN 12390-3","search_en":"Hardened concrete Determination of compressive strength of test specimens ČSN EN 12390-3","search_zh":"硬化混凝土 试件抗压强度测定 ČSN EN 12390-3","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":4,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"fd5b525ebc9d2c8e5218b3d6","lab_id":"69ad52a4de79e566650fd276","country":"CZ","accr_number":"1122","accr_body":"ČIA","row_label":"3","test_object":"Beton stwardniały","test_object_en":"Hardened concrete","test_object_zh":"硬化混凝土","test_object_cs":"Ztvrdlý beton","methodology":"Oznaczanie wytrzymałości na ściskanie próbek do badań","methodology_en":"Determination of compressive strength of test specimens","methodology_zh":"试件抗压强度测定","methodology_cs":"Stanovení pevnosti v tlaku zkušebních těles","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie wytrzymałości na ściskanie próbek do badań","reference":"ČSN EN 12390-3","norm_bases":["ČSN EN 12390-3"],"lab_section":"Laboratorium Badawcze - Ołomuniec","lab_section_en":"Testing Laboratory - Olomouc","lab_section_zh":"检测实验室 - 奥洛穆茨","lab_section_cs":"Zkušební laboratoř - Olomouc","lab_address":"Pavelkova 8/1177, 779 00 Olomouc","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Beton stwardniały Oznaczanie wytrzymałości na ściskanie próbek do badań Ztvrdlý beton Stanovení pevnosti v tlaku zkušebních těles ČSN EN 12390-3 Beton stwardnialy Oznaczanie wytrzymalosci na sciskanie probek do badan Ztvrdly beton Stanoveni pevnosti v tlaku zkusebnich teles CSN EN 12390-3","search_en":"Hardened concrete Determination of compressive strength of test specimens ČSN EN 12390-3","search_zh":"硬化混凝土 试件抗压强度测定 ČSN EN 12390-3","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":5,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"c663ba13e30c8c61d5a9cd74","lab_id":"69ad52a4de79e566650fd276","country":"CZ","accr_number":"1122","accr_body":"ČIA","row_label":"4","test_object":"Beton stwardniały","test_object_en":"Hardened concrete","test_object_zh":"硬化混凝土","test_object_cs":"Ztvrdlý beton","methodology":"Oznaczanie gęstości","methodology_en":"Determination of density","methodology_zh":"密度测定","methodology_cs":"Stanovení objemové hmotnosti","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie gęstości","reference":"ČSN EN 12390-7, čl. 6.1.2 c)","norm_bases":["ČSN EN 12390-7, čl. 6.1.2 c)"],"lab_section":"Laboratorium Badawcze - Letňany","lab_section_en":"Testing Laboratory - Letňany","lab_section_zh":"检测实验室 - 莱特尼亚尼","lab_section_cs":"Zkušební laboratoř - Letňany","lab_address":"Toužimská 664, 199 00 Praha 9 - Letňany","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Beton stwardniały Oznaczanie gęstości Ztvrdlý beton Stanovení objemové hmotnosti ČSN EN 12390-7, čl. 6.1.2 c) Beton stwardnialy Oznaczanie gestosci Ztvrdly beton Stanoveni objemove hmotnosti CSN EN 12390-7, cl. 6.1.2 c)","search_en":"Hardened concrete Determination of density ČSN EN 12390-7, čl. 6.1.2 c)","search_zh":"硬化混凝土 密度测定 ČSN EN 12390-7, čl. 6.1.2 c)","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":6,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"93366289f3d686b5b6793e8f","lab_id":"69ad52a4de79e566650fd276","country":"CZ","accr_number":"1122","accr_body":"ČIA","row_label":"4","test_object":"Beton stwardniały","test_object_en":"Hardened concrete","test_object_zh":"硬化混凝土","test_object_cs":"Ztvrdlý beton","methodology":"Oznaczanie gęstości","methodology_en":"Determination of density","methodology_zh":"密度测定","methodology_cs":"Stanovení objemové hmotnosti","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie gęstości","reference":"ČSN EN 12390-7, čl. 6.1.2 c)","norm_bases":["ČSN EN 12390-7, čl. 6.1.2 c)"],"lab_section":"Laboratorium Badawcze - Ołomuniec","lab_section_en":"Testing Laboratory - Olomouc","lab_section_zh":"检测实验室 - 奥洛穆茨","lab_section_cs":"Zkušební laboratoř - Olomouc","lab_address":"Pavelkova 8/1177, 779 00 Olomouc","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Beton stwardniały Oznaczanie gęstości Ztvrdlý beton Stanovení objemové hmotnosti ČSN EN 12390-7, čl. 6.1.2 c) Beton stwardnialy Oznaczanie gestosci Ztvrdly beton Stanoveni objemove hmotnosti CSN EN 12390-7, cl. 6.1.2 c)","search_en":"Hardened concrete Determination of density ČSN EN 12390-7, čl. 6.1.2 c)","search_zh":"硬化混凝土 密度测定 ČSN EN 12390-7, čl. 6.1.2 c)","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":7,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"50b57c94517f871ed944e0a1","lab_id":"69ad52a4de79e566650fd276","country":"CZ","accr_number":"1122","accr_body":"ČIA","row_label":"5","test_object":"Beton stwardniały","test_object_en":"Hardened concrete","test_object_zh":"硬化混凝土","test_object_cs":"Ztvrdlý beton","methodology":"Oznaczanie głębokości penetracji wody pod ciśnieniem","methodology_en":"Determination of depth of penetration of water under pressure","methodology_zh":"压力水渗透深度测定","methodology_cs":"Stanovení hloubky průsaku tlakovou vodou","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie głębokości penetracji wody pod ciśnieniem","reference":"ČSN EN 12390-8","norm_bases":["ČSN EN 12390-8"],"lab_section":"Laboratorium Badawcze - Letňany","lab_section_en":"Testing Laboratory - Letňany","lab_section_zh":"检测实验室 - 莱特尼亚尼","lab_section_cs":"Zkušební laboratoř - Letňany","lab_address":"Toužimská 664, 199 00 Praha 9 - Letňany","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Beton stwardniały Oznaczanie głębokości penetracji wody pod ciśnieniem Ztvrdlý beton Stanovení hloubky průsaku tlakovou vodou ČSN EN 12390-8 Beton stwardnialy Oznaczanie glebokosci penetracji wody pod cisnieniem Ztvrdly beton Stanoveni hloubky prusaku tlakovou vodou CSN EN 12390-8","search_en":"Hardened concrete Determination of depth of penetration of water under pressure ČSN EN 12390-8","search_zh":"硬化混凝土 压力水渗透深度测定 ČSN EN 12390-8","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":8,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"2a568593f9a80df388f44d92","lab_id":"69ad52a4de79e566650fd276","country":"CZ","accr_number":"1122","accr_body":"ČIA","row_label":"5","test_object":"Beton stwardniały","test_object_en":"Hardened concrete","test_object_zh":"硬化混凝土","test_object_cs":"Ztvrdlý beton","methodology":"Oznaczanie głębokości penetracji wody pod ciśnieniem","methodology_en":"Determination of depth of penetration of water under pressure","methodology_zh":"压力水渗透深度测定","methodology_cs":"Stanovení hloubky průsaku tlakovou vodou","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie głębokości penetracji wody pod ciśnieniem","reference":"ČSN EN 12390-8","norm_bases":["ČSN EN 12390-8"],"lab_section":"Laboratorium Badawcze - Ołomuniec","lab_section_en":"Testing Laboratory - Olomouc","lab_section_zh":"检测实验室 - 奥洛穆茨","lab_section_cs":"Zkušební laboratoř - Olomouc","lab_address":"Pavelkova 8/1177, 779 00 Olomouc","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Beton stwardniały Oznaczanie głębokości penetracji wody pod ciśnieniem Ztvrdlý beton Stanovení hloubky průsaku tlakovou vodou ČSN EN 12390-8 Beton stwardnialy Oznaczanie glebokosci penetracji wody pod cisnieniem Ztvrdly beton Stanoveni hloubky prusaku tlakovou vodou CSN EN 12390-8","search_en":"Hardened concrete Determination of depth of penetration of water under pressure ČSN EN 12390-8","search_zh":"硬化混凝土 压力水渗透深度测定 ČSN EN 12390-8","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":9,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"a5d069f8d50f937cd1a75804","lab_id":"69ad52a4de79e566650fd276","country":"CZ","accr_number":"1122","accr_body":"ČIA","row_label":"6","test_object":"Beton stwardniały","test_object_en":"Hardened concrete","test_object_zh":"硬化混凝土","test_object_cs":"Ztvrdlý beton","methodology":"Oznaczanie odporności powierzchni betonu cementowego na działanie wody i chemicznych środków odladzających","methodology_en":"Determination of resistance of cement concrete surface to water and chemical de-icing agents","methodology_zh":"水泥混凝土表面抗水及化学除冰剂性能测定","methodology_cs":"Stanovení odolnosti povrchu cementového betonu proti působení vody a chemických rozmrazovacích látek","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie odporności powierzchni betonu cementowego na działanie wody i chemicznych środków odladzających","reference":"ČSN 73 1326, metoda A, čl. 13-23","norm_bases":["ČSN 73 1326, metoda A, čl. 13-23"],"lab_section":"Laboratorium Badawcze - Letňany","lab_section_en":"Testing Laboratory - Letňany","lab_section_zh":"检测实验室 - 莱特尼亚尼","lab_section_cs":"Zkušební laboratoř - Letňany","lab_address":"Toužimská 664, 199 00 Praha 9 - Letňany","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Beton stwardniały Oznaczanie odporności powierzchni betonu cementowego na działanie wody i chemicznych środków odladzających Ztvrdlý beton Stanovení odolnosti povrchu cementového betonu proti působení vody a chemických rozmrazovacích látek ČSN 73 1326, metoda A, čl. 13-23 Beton stwardnialy Oznaczanie odpornosci powierzchni betonu cementowego na dzialanie wody i chemicznych srodkow odladzajacych Ztvrdly beton Stanoveni odolnosti povrchu cementoveho betonu proti pusobeni vody a chemickych rozmrazovacich latek CSN 73 1326, metoda A, cl. 13-23","search_en":"Hardened concrete Determination of resistance of cement concrete surface to water and chemical de-icing agents ČSN 73 1326, metoda A, čl. 13-23","search_zh":"硬化混凝土 水泥混凝土表面抗水及化学除冰剂性能测定 ČSN 73 1326, metoda A, čl. 13-23","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":10,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"c36bfe1775a1332d9a55849e","lab_id":"69ad52a4de79e566650fd276","country":"CZ","accr_number":"1122","accr_body":"ČIA","row_label":"6","test_object":"Beton stwardniały","test_object_en":"Hardened concrete","test_object_zh":"硬化混凝土","test_object_cs":"Ztvrdlý beton","methodology":"Oznaczanie odporności powierzchni betonu cementowego na działanie wody i chemicznych środków odladzających","methodology_en":"Determination of resistance of cement concrete surface to water and chemical de-icing agents","methodology_zh":"水泥混凝土表面抗水及化学除冰剂性能测定","methodology_cs":"Stanovení odolnosti povrchu cementového betonu proti působení vody a chemických rozmrazovacích látek","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":null,"technique_en":null,"technique_zh":null,"technique_cs":null,"techniques":[],"techniques_en":[],"techniques_zh":[],"techniques_cs":[],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie odporności powierzchni betonu cementowego na działanie wody i chemicznych środków odladzających","reference":"ČSN 73 1326, metoda A, čl. 13-23","norm_bases":["ČSN 73 1326, metoda A, čl. 13-23"],"lab_section":"Laboratorium Badawcze - Ołomuniec","lab_section_en":"Testing Laboratory - Olomouc","lab_section_zh":"检测实验室 - 奥洛穆茨","lab_section_cs":"Zkušební laboratoř - Olomouc","lab_address":"Pavelkova 8/1177, 779 00 Olomouc","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Beton stwardniały Oznaczanie odporności powierzchni betonu cementowego na działanie wody i chemicznych środków odladzających Ztvrdlý beton Stanovení odolnosti povrchu cementového betonu proti působení vody a chemických rozmrazovacích látek ČSN 73 1326, metoda A, čl. 13-23 Beton stwardnialy Oznaczanie odpornosci powierzchni betonu cementowego na dzialanie wody i chemicznych srodkow odladzajacych Ztvrdly beton Stanoveni odolnosti povrchu cementoveho betonu proti pusobeni vody a chemickych rozmrazovacich latek CSN 73 1326, metoda A, cl. 13-23","search_en":"Hardened concrete Determination of resistance of cement concrete surface to water and chemical de-icing agents ČSN 73 1326, metoda A, čl. 13-23","search_zh":"硬化混凝土 水泥混凝土表面抗水及化学除冰剂性能测定 ČSN 73 1326, metoda A, čl. 13-23","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":11,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"cc274d8452633bd2ab79bfd8","lab_id":"69ad52a4de79e566650fd276","country":"CZ","accr_number":"1122","accr_body":"ČIA","row_label":"7","test_object":"Kruszywo","test_object_en":"Aggregate","test_object_zh":"集料","test_object_cs":"Kamenivo","methodology":"Oznaczanie uziarnienia","methodology_en":"Determination of particle size distribution","methodology_zh":"颗粒级配测定","methodology_cs":"Stanovení zrnitosti","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"Analiza sitowa","technique_en":"Sieving method","technique_zh":"筛分法","technique_cs":"sítový rozbor","techniques":["Analiza sitowa"],"techniques_en":["Sieving method"],"techniques_zh":["筛分法"],"techniques_cs":["sítový rozbor"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie uziarnienia\nAnaliza sitowa","reference":"ČSN EN 933-1","norm_bases":["ČSN EN 933-1"],"lab_section":"Laboratorium Badawcze - Letňany","lab_section_en":"Testing Laboratory - Letňany","lab_section_zh":"检测实验室 - 莱特尼亚尼","lab_section_cs":"Zkušební laboratoř - Letňany","lab_address":"Toužimská 664, 199 00 Praha 9 - Letňany","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Kruszywo Oznaczanie uziarnienia Analiza sitowa Kamenivo Stanovení zrnitosti sítový rozbor ČSN EN 933-1 Kruszywo Oznaczanie uziarnienia Analiza sitowa Kamenivo Stanoveni zrnitosti sitovy rozbor CSN EN 933-1","search_en":"Aggregate Determination of particle size distribution Sieving method ČSN EN 933-1","search_zh":"集料 颗粒级配测定 筛分法 ČSN EN 933-1","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":12,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"fa47c07d30d2eb62cf36e4ea","lab_id":"69ad52a4de79e566650fd276","country":"CZ","accr_number":"1122","accr_body":"ČIA","row_label":"7","test_object":"Kruszywo","test_object_en":"Aggregate","test_object_zh":"集料","test_object_cs":"Kamenivo","methodology":"Oznaczanie uziarnienia","methodology_en":"Determination of particle size distribution","methodology_zh":"颗粒级配测定","methodology_cs":"Stanovení zrnitosti","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"Analiza sitowa","technique_en":"Sieving method","technique_zh":"筛分法","technique_cs":"sítový rozbor","techniques":["Analiza sitowa"],"techniques_en":["Sieving method"],"techniques_zh":["筛分法"],"techniques_cs":["sítový rozbor"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Oznaczanie uziarnienia\nAnaliza sitowa","reference":"ČSN EN 933-1","norm_bases":["ČSN EN 933-1"],"lab_section":"Laboratorium Badawcze - Ołomuniec","lab_section_en":"Testing Laboratory - Olomouc","lab_section_zh":"检测实验室 - 奥洛穆茨","lab_section_cs":"Zkušební laboratoř - Olomouc","lab_address":"Pavelkova 8/1177, 779 00 Olomouc","regulatory_area":"Badania","regulatory_area_en":"Tests","regulatory_area_zh":"检测","regulatory_area_cs":"Zkoušky","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Kruszywo Oznaczanie uziarnienia Analiza sitowa Kamenivo Stanovení zrnitosti sítový rozbor ČSN EN 933-1 Kruszywo Oznaczanie uziarnienia Analiza sitowa Kamenivo Stanoveni zrnitosti sitovy rozbor CSN EN 933-1","search_en":"Aggregate Determination of particle size distribution Sieving method ČSN EN 933-1","search_zh":"集料 颗粒级配测定 筛分法 ČSN EN 933-1","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":13,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"6f22fa3143826ca6ae30ab9b","lab_id":"69ad52a4de79e566650fd276","country":"CZ","accr_number":"1122","accr_body":"ČIA","row_label":"1","test_object":"Mieszanka betonowa (beton świeży)","test_object_en":"Fresh concrete","test_object_zh":"新拌混凝土","test_object_cs":"Čerstvý beton","methodology":"Pobieranie próbek mieszanki betonowej","methodology_en":"Sampling of fresh concrete","methodology_zh":"新拌混凝土取样","methodology_cs":"Odběr vzorků čerstvého betonu","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"Metoda ręczna","technique_en":"Manual","technique_zh":"手工","technique_cs":"manuálně","techniques":["Metoda ręczna"],"techniques_en":["Manual"],"techniques_zh":["手工"],"techniques_cs":["manuálně"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pobieranie próbek mieszanki betonowej\nMetoda ręczna","reference":"ČSN EN 12350-1","norm_bases":["ČSN EN 12350-1"],"lab_section":"Laboratorium Badawcze - Letňany","lab_section_en":"Testing Laboratory - Letňany","lab_section_zh":"检测实验室 - 莱特尼亚尼","lab_section_cs":"Zkušební laboratoř - Letňany","lab_address":"Toužimská 664, 199 00 Praha 9 - Letňany","regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Mieszanka betonowa (beton świeży) Pobieranie próbek mieszanki betonowej Metoda ręczna Čerstvý beton Odběr vzorků čerstvého betonu manuálně ČSN EN 12350-1 Mieszanka betonowa (beton swiezy) Pobieranie probek mieszanki betonowej Metoda reczna Cerstvy beton Odber vzorku cerstveho betonu manualne CSN EN 12350-1","search_en":"Fresh concrete Sampling of fresh concrete Manual ČSN EN 12350-1","search_zh":"新拌混凝土 新拌混凝土取样 手工 ČSN EN 12350-1","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":14,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"a823446e240d927e3d37bac8","lab_id":"69ad52a4de79e566650fd276","country":"CZ","accr_number":"1122","accr_body":"ČIA","row_label":"1","test_object":"Mieszanka betonowa (beton świeży)","test_object_en":"Fresh concrete","test_object_zh":"新拌混凝土","test_object_cs":"Čerstvý beton","methodology":"Pobieranie próbek mieszanki betonowej","methodology_en":"Sampling of fresh concrete","methodology_zh":"新拌混凝土取样","methodology_cs":"Odběr vzorků čerstvého betonu","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"Metoda ręczna","technique_en":"Manual","technique_zh":"手工","technique_cs":"manuálně","techniques":["Metoda ręczna"],"techniques_en":["Manual"],"techniques_zh":["手工"],"techniques_cs":["manuálně"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pobieranie próbek mieszanki betonowej\nMetoda ręczna","reference":"ČSN EN 12350-1","norm_bases":["ČSN EN 12350-1"],"lab_section":"Laboratorium Badawcze - Ołomuniec","lab_section_en":"Testing Laboratory - Olomouc","lab_section_zh":"检测实验室 - 奥洛穆茨","lab_section_cs":"Zkušební laboratoř - Olomouc","lab_address":"Pavelkova 8/1177, 779 00 Olomouc","regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Mieszanka betonowa (beton świeży) Pobieranie próbek mieszanki betonowej Metoda ręczna Čerstvý beton Odběr vzorků čerstvého betonu manuálně ČSN EN 12350-1 Mieszanka betonowa (beton swiezy) Pobieranie probek mieszanki betonowej Metoda reczna Cerstvy beton Odber vzorku cerstveho betonu manualne CSN EN 12350-1","search_en":"Fresh concrete Sampling of fresh concrete Manual ČSN EN 12350-1","search_zh":"新拌混凝土 新拌混凝土取样 手工 ČSN EN 12350-1","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":15,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"ced256efac48a82ca703a4bf","lab_id":"69ad52a4de79e566650fd276","country":"CZ","accr_number":"1122","accr_body":"ČIA","row_label":"2","test_object":"Kruszywo","test_object_en":"Aggregate","test_object_zh":"集料","test_object_cs":"Kamenivo","methodology":"Pobieranie próbek i pomniejszanie próbek kruszywa","methodology_en":"Sampling and reducing of aggregate samples","methodology_zh":"集料取样及缩分","methodology_cs":"Odběr vzorků a zmenšování vzorků kameniva","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"Metoda ręczna","technique_en":"Manual","technique_zh":"手工","technique_cs":"manuálně","techniques":["Metoda ręczna"],"techniques_en":["Manual"],"techniques_zh":["手工"],"techniques_cs":["manuálně"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pobieranie próbek i pomniejszanie próbek kruszywa\nMetoda ręczna","reference":"ČSN EN 932-1; ČSN EN 932-2","norm_bases":["ČSN EN 932-1","ČSN EN 932-2"],"lab_section":"Laboratorium Badawcze - Letňany","lab_section_en":"Testing Laboratory - Letňany","lab_section_zh":"检测实验室 - 莱特尼亚尼","lab_section_cs":"Zkušební laboratoř - Letňany","lab_address":"Toužimská 664, 199 00 Praha 9 - Letňany","regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Kruszywo Pobieranie próbek i pomniejszanie próbek kruszywa Metoda ręczna Kamenivo Odběr vzorků a zmenšování vzorků kameniva manuálně ČSN EN 932-1; ČSN EN 932-2 Kruszywo Pobieranie probek i pomniejszanie probek kruszywa Metoda reczna Kamenivo Odber vzorku a zmensovani vzorku kameniva manualne CSN EN 932-1; CSN EN 932-2","search_en":"Aggregate Sampling and reducing of aggregate samples Manual ČSN EN 932-1; ČSN EN 932-2","search_zh":"集料 集料取样及缩分 手工 ČSN EN 932-1; ČSN EN 932-2","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":16,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"},{"_id":"ab98b0767a883f8846070471","lab_id":"69ad52a4de79e566650fd276","country":"CZ","accr_number":"1122","accr_body":"ČIA","row_label":"2","test_object":"Kruszywo","test_object_en":"Aggregate","test_object_zh":"集料","test_object_cs":"Kamenivo","methodology":"Pobieranie próbek i pomniejszanie próbek kruszywa","methodology_en":"Sampling and reducing of aggregate samples","methodology_zh":"集料取样及缩分","methodology_cs":"Odběr vzorků a zmenšování vzorků kameniva","parameters":[],"parameters_en":[],"parameters_zh":[],"parameters_cs":[],"technique":"Metoda ręczna","technique_en":"Manual","technique_zh":"手工","technique_cs":"manuálně","techniques":["Metoda ręczna"],"techniques_en":["Manual"],"techniques_zh":["手工"],"techniques_cs":["manuálně"],"computed":[],"computed_en":[],"computed_zh":[],"computed_cs":[],"activity":"Pobieranie próbek i pomniejszanie próbek kruszywa\nMetoda ręczna","reference":"ČSN EN 932-1; ČSN EN 932-2","norm_bases":["ČSN EN 932-1","ČSN EN 932-2"],"lab_section":"Laboratorium Badawcze - Ołomuniec","lab_section_en":"Testing Laboratory - Olomouc","lab_section_zh":"检测实验室 - 奥洛穆茨","lab_section_cs":"Zkušební laboratoř - Olomouc","lab_address":"Pavelkova 8/1177, 779 00 Olomouc","regulatory_area":"Pobieranie próbek","regulatory_area_en":"Sampling","regulatory_area_zh":"采样","regulatory_area_cs":"Vzorkování","flexible":false,"flexibility":null,"outside_premises":false,"note":null,"note_en":null,"note_zh":null,"note_cs":null,"search_text":"Kruszywo Pobieranie próbek i pomniejszanie próbek kruszywa Metoda ręczna Kamenivo Odběr vzorků a zmenšování vzorků kameniva manuálně ČSN EN 932-1; ČSN EN 932-2 Kruszywo Pobieranie probek i pomniejszanie probek kruszywa Metoda reczna Kamenivo Odber vzorku a zmensovani vzorku kameniva manualne CSN EN 932-1; CSN EN 932-2","search_en":"Aggregate Sampling and reducing of aggregate samples Manual ČSN EN 932-1; ČSN EN 932-2","search_zh":"集料 集料取样及缩分 手工 ČSN EN 932-1; ČSN EN 932-2","categories":["construction"],"categories_source":"reczne","source_lang":"cs","translation":{"pl":"reczna-analiza-labcoda-3","en":"reczna-analiza-labcoda-3","zh":"reczna-analiza-labcoda-3"},"row_index":17,"parse_version":5,"parse_source":"reczna-analiza-labcoda-3"}],"has_pdf":true}