🇨🇿 BIOANALYTIKA CZ, s.r.o. PL
Water & wastewaterEnvironmentMetrology & calibration
BIOANALYTIKA CZ, s.r.o. is a laboratory accredited by ČIA under number 1012 (Chrudim, Czech Republic). Its accreditation scope covers 176 test methods in the following areas: Water & wastewater, Environment, Metrology & calibration. Test objects include: Water, aqueous leachate, Emissions, Soils, sediments, sludge, solid waste, Water, hot water, aqueous leachate.
At a glance
- Accreditation number: ČIA 1012
- Methods in scope: 176
- Types of test objects: 74
- City: Chrudim, Czech Republic
- Valid until: 04-11-2030
- Accreditation number
- 1012
- Accreditation body
- ČIA
- Address
- Píšťovy 820, Chrudim III, 537 01 Chrudim
- City
- Chrudim, Czech Republic
- Division
- Laboratorium Chrudim
- Valid until
- 04-11-2030
What this laboratory tests (74)
- Water, aqueous leachate — 23 methods
- Emissions — 12 methods
- Soils, sediments, sludge, solid waste — 11 methods
- Water, hot water, aqueous leachate — 7 methods
- Emissions, working, indoor and outdoor air (absorbate) — 5 methods
- Water — 5 methods
- Water, bathing water, aqueous leachate — 5 methods
- Soils, sludge, sediments, solid waste — 4 methods
- Soils, waste, water, aqueous leachate — 4 methods
- Working environment, emissions (absorbate, condensate, filter) — 4 methods
- Working, indoor and outdoor air — 4 methods
- Construction materials, materials from construction — 3 methods
- Drinking water — 3 methods
- Drinking water, bottled water, surface water, ground water — 3 methods
- Drinking water, surface water, waste water, bathing water — 3 methods
- and 59 more
Laboratory sections (2)
- Laboratory Chrudim — 144 methods
- Dražkovice workplace — 32 methods
Laboratory locations
- Laboratorium Chrudim — Píšťovy 820, Chrudim III
- Oddział Dražkovice — Dražkovice č. p. 212
Certificate information
- Certificate date
- 04.11.2025
Accreditation scope — test methods (176)
| No. | Test object | Methodology / Parameters | Technique | Reference document | |
|---|---|---|---|---|---|
| Laboratory Chrudim | |||||
| 1 | Soils, sludge, sediments, solid waste, composts | Determination of dry matter by gravimetry Regulated area: 1 Gravimetric methods |
SOP - 13 (JPP ÚKZÚZ Brno 2020; ČSN EN 15934) | ||
| 2 | Soils, sludge, sediments, solid waste, composts | Determination of combustibles (ash) by gravimetry Regulated area: 1 Gravimetric methods |
SOP - 14 (JPP ÚKZÚZ Brno 2020; ČSN EN 15935) | ||
| 3 | Water, aqueous leachate | Determination of dissolved solids (RL 105 °C) by gravimetry Regulated area: 1 Gravimetric methods |
SOP - 15 (ČSN 75 7346) | ||
| 4 | Water | Determination of suspended solids (NL105 °C) and loss on ignition of suspended solids (NL 550 °C) by gravimetry Regulated area: 1 Gravimetric methods |
SOP - 16 (ČSN EN 872; ČSN 75 7350) | ||
| 5 | Water, aqueous leachate | Determination of dissolved inorganic salts (RAS) by gravimetric method after filtration through glass fibre filters Regulated area: 1 Gravimetric methods |
SOP - 17 (ČSN 75 7347) | ||
| 6 | Water, hot water, aqueous leachate | Determination of chemical oxygen demand with dichromate (CODCr) by titration Regulated area: 2 Titrimetric methods |
SOP - 21 (ČSN ISO 6060) | ||
| 7 | Water, bathing water, hot water, aqueous leachate | Determination of chemical oxygen demand with permanganate (COD-Mn) by titration Regulated area: 2 Titrimetric methods |
SOP - 22 (ČSN EN ISO 8467) | ||
| 8 | Water, aqueous leachate | Determination of chloride by silver nitrate titration according to Mohr and calculation of the content of water-soluble chlorides in dry matter from the values determined for the aqueous leachate Regulated area: 2 Titrimetric methods |
SOP - 34 (ČSN ISO 9297) | ||
| 9 | Water, aqueous leachate | Determination of sulphate by titration with lead nitrate and calculation of the content of water-soluble sulphate in dry matter from the values determined for the aqueous leachate Regulated area: 2 Titrimetric methods |
SOP - 36 (ČSN 75 7477) | ||
| 10 | Drinking, ground water | Determination of acid neutralizing capacity (ANC4,5 and ANC8,3) by neutralization titration and calculation of carbon dioxide forms from measured values of ANC and base neutralizing capacity BNC Regulated area: 2 Titrimetric methods |
SOP - 37 (ČSN EN ISO 9963-1; ČSN 75 7373) | ||
| 11 | Drinking, ground water | Determination of base neutralizing capacity (BNC8,3 and BNC4,5) by neutralization titration Regulated area: 2 Titrimetric methods |
SOP - 38 (ČSN 75 7372) | ||
| 12 | Drinking water, bottled water, surface water, ground water | Determination of calcium and magnesium (water hardness) by complexometry Regulated area: 2 Titrimetric methods |
SOP - 39 A (ČSN ISO 6059) | ||
| 13 | Drinking water, bottled water, surface water, ground water | Determination of calcium by complexometry and magnesium by calculation from measured values Regulated area: 2 Titrimetric methods |
SOP - 39 B (ČSN ISO 6058) | ||
| 14 | Soils, sludge, sediments, treated biowaste, composts | Determination of total nitrogen according to Kjeldahl by titration and C:N ratio from measured values Regulated area: 2 Titrimetric methods |
SOP - 126 (ČSN EN 16169; ČSN EN 13342; ČSN ISO 11261; ČSN EN 13654-1) | ||
| 15 | Water, bathing water | Determination of redox potential (ORP) Regulated area: 3 Electrochemical methods |
SOP - 02 (ČSN 75 7367) | ||
| 16 | Water, hot water, bathing water, aqueous leachate | Determination of pH by potentiometry Regulated area: 3 Electrochemical methods |
SOP - 10 A (ČSN ISO 10523) | ||
| 17 | Water, hot water, bathing water | Determination of pH by potentiometry Regulated area: 3 Electrochemical methods |
SOP - 10 B (ČSN ISO 10523) | ||
| 18 | Soils, sludge, sediments, solid waste, composts | Determination of pH by potentiometry Regulated area: 3 Electrochemical methods |
SOP - 11 (JPP ÚKZÚZ Brno 2010; ČSN EN ISO 10390) | ||
| 19 | Water, aqueous leachate | Determination of electrical conductivity Regulated area: 3 Electrochemical methods |
SOP - 12 A (ČSN EN 27888) | ||
| 20 | Water | Determination of electrical conductivity Regulated area: 3 Electrochemical methods |
SOP - 12 B (ČSN EN 27888) | ||
| 21 | Water, bathing water | Determination of dissolved oxygen – electrochemical probe method Regulated area: 3 Electrochemical methods |
SOP - 06 B (ČSN EN ISO 5814) | ||
| 22 | Water, aqueous leachate | Determination of fluoride by ion selective electrode Regulated area: 3 Electrochemical methods |
SOP - 18 (ČSN ISO 10359-1) | ||
| 23 | Water, aqueous leachate | Determination of chloride by argentometry with microcoulometric generation of Ag+ and potentiometric detection of equivalence point and calculation of the content of water-soluble chlorides in dry matter from the values determined for the aqueous leachate Regulated area: 3 Electrochemical methods |
SOP - 35 (Firemní manuál LABTECH) | ||
| 24 | Water, aqueous leachate | Determination of adsorbable organically bound halogens (AOX) by coulometry Regulated area: 3 Electrochemical methods |
SOP - 81 (ČSN EN ISO 9562; TNI 75 7531) | ||
| 25 | Soils, sludge, sediments, solid waste | Determination of adsorbable organically bound halogens (AOX) by coulometry Regulated area: 3 Electrochemical methods |
SOP - 96 (ČSN EN 16166) | ||
| 26 | Soils, sludge, sediments, solid waste | Determination of extractable organically bound halogens (EOX) by coulometry Regulated area: 3 Electrochemical methods |
SOP - 95 (DIN 38414-17:2014) | ||
| 27 | Water, aqueous leachate | Determination of bromates, chlorites and chlorates by capillary electrophoresis Regulated area: 3 Electrochemical methods |
SOP - 119 (Aplikační list č. 24 firmy Villa Labeco, s.r.o.) | ||
| 28 | Emissions, working, indoor and outdoor air (absorbate) | Determination of mass concentration of gaseous inorganic compounds of fluorine by ion selective electrode Regulated area: 3 Electrochemical methods |
SOP - 207 (ČSN P CEN/TS 17340) | ||
| 29 | Emissions, working, indoor and outdoor air (absorbate) | Determination of mass concentration of gaseous inorganic compounds of chlorine by argentometry with microcoulometric generation of Ag+ and potentiometric detection of equivalence point Regulated area: 3 Electrochemical methods |
SOP - 208 (ČSN EN 1911; Návod firmy LABTECH) | ||
| 30 | Drinking, bottled water, hot water, bathing water | Determination of free and total chlorine by spectrophotometry using a commercial analytical kit and calculation of bound chlorine from measured values Regulated area: 4 Spectrophotometric and spectral methods |
SOP - 03 A (Návod firmy HANNA; Návod firmy HACH) | ||
| 31 | Water, bathing water | Determination of dissolved oxygen – method with optical sensor Regulated area: 4 Spectrophotometric and spectral methods |
SOP - 06 A (ČSN ISO 17289) | ||
| 32 | Drinking water, bathing water, bottled water | Determination of ozone by spectrophotometry using a commercial analytical kit Regulated area: 4 Spectrophotometric and spectral methods |
SOP - 07 (Návod firmy HACH) | ||
| 33 | Drinking, bottled water, hot water, bathing water, ground water, surface water | Determination of turbidity by nephelometry – commercial analytical kit Regulated area: 4 Spectrophotometric and spectral methods |
SOP - 09 A (ČSN EN ISO 7027-1; Návod firmy Lovibond; Návod firmy HACH) | ||
| 34 | Drinking, bottled water, hot water, bathing water, ground water, surface water | Determination of turbidity by turbidimetry – commercial analytical kit Regulated area: 4 Spectrophotometric and spectral methods |
SOP - 09 B (Návod firmy Lovibond; Návod firmy HANNA) | ||
| 35 | Drinking, bottled water, hot water, bathing water | Determination of chlorine dioxide by spectrophotometry – commercial analytical kit Regulated area: 4 Spectrophotometric and spectral methods |
SOP - 03 B (Návod firmy HACH) | ||
| 36 | Water | Determination of biochemical oxygen demand (BOD-5) by standard dilution method with nitrification suppression (optical probe measurement) Regulated area: 4 Spectrophotometric and spectral methods |
SOP - 19 (ČSN EN ISO 5815-1) | ||
| 37 | Water, hot water, aqueous leachate | Determination of chemical oxygen demand with dichromate (COD-Cr) by spectrophotometry – commercial analytical kit Regulated area: 4 Spectrophotometric and spectral methods |
SOP - 20 (ČSN ISO 15705; Návod firmy HACH; Návod firmy Merck) | ||
| 38 | Water, hot water, aqueous leachate | Determination of ammonium (NH4+) by manual spectrophotometric method, ammonia nitrogen (N-NH4) and free ammonia (NH3) by calculation from measured values Regulated area: 4 Spectrophotometric and spectral methods |
SOP - 23 (ČSN ISO 7150-1; Pitter P. a kol.: Hydrochemie, 4. vydání, VŠCHT Praha 2009) | ||
| 39 | Water, hot water, aqueous leachate | Determination of nitrite (NO2) by spectrophotometry with sulfanilic acid and N-(1-naphthyl)-1,2-ethylenediaminedihydrochloride and nitrite nitrogen (N-NO2) by calculation from measured values Regulated area: 4 Spectrophotometric and spectral methods |
SOP - 24 (ČSN EN 26777) | ||
| 40 | Soils, sediments, sludge, solid waste | Determination of nitrate nitrogen (N-NO3) by spectrophotometry Regulated area: 4 Spectrophotometric and spectral methods |
SOP - 25 (JPP ÚKZÚZ, Brno 2011; ČSN 75 7455) | ||
| 41 | Drinking, bottled water | Determination of nitrate (NO3) by spectrophotometry in UV range Regulated area: 4 Spectrophotometric and spectral methods |
SOP - 26 (Horáková M. a kol.: Chemické a fyzikální metody analýzy vod, Praha 1986) | ||
| 42 | Water, hot water, aqueous leachate | Determination of total nitrogen (N-total) as nitrate by spectrophotometry after oxidation with Merck Crack Set agent and inorganic nitrogen (N-inorg) by calculation from the measured values Regulated area: 4 Spectrophotometric and spectral methods |
SOP - 27 (Návod firmy Merck) | ||
| 43 | Water, hot water, aqueous leachate | Determination of dissolved inorganic phosphates by spectrophotometry – commercial analytical kit Regulated area: 4 Spectrophotometric and spectral methods |
SOP - 28 (Návod firmy Merck) | ||
| 44 | Water, aqueous leachate | Determination of total phosphorus (P-total) by spectrophotometry after transformation to phosphate by Merck Crack Set agent Regulated area: 4 Spectrophotometric and spectral methods |
SOP - 29 (Návod firmy Merck) | ||
| 45 | Soils, sediments, sludge, solid waste | Determination of ammonia nitrogen (N-NH4) by spectrophotometry Regulated area: 4 Spectrophotometric and spectral methods |
SOP - 30 (JPP ÚKZÚZ, Brno 2011) | ||
| 46 | Water, aqueous leachate | Determination of total and free cyanides after distillation by spectrophotometry Regulated area: 4 Spectrophotometric and spectral methods |
SOP - 31 (ČSN ISO 6703-1:1995; ČSN ISO 6703-2; ČSN 75 7415) | ||
| 47 | Soils, solid waste | Determination of total cyanide after distillation by spectrophotometry Regulated area: 4 Spectrophotometric and spectral methods |
SOP - 52 (EPA Method 9013A; ČSN 75 7415) | ||
| 48 | Water, aqueous leachate | Determination of univalent phenols volatilising with water steam by spectrophotometry with 4-aminoantipyrine Regulated area: 4 Spectrophotometric and spectral methods |
SOP - 32 (ČSN ISO 6439) | ||
| 49 | Soils, sediments, solid waste | Determination of phenols volatilising with water steam by spectrophotometry with 4-aminoantipyrine Regulated area: 4 Spectrophotometric and spectral methods |
SOP - 53 (EPA Method 420.1; ČSN ISO 6439) | ||
| 50 | Emissions, working, indoor and outdoor air (absorbate), water, aqueous leachate | Determination of the mass concentration of phenols by spectrophotometry – commercial analytical kit Regulated area: 4 Spectrophotometric and spectral methods |
SOP - 219 (Návod firmy Merck) | ||
| 51 | Water, aqueous leachate | Determination of hexavalent chromium (CrVI+) by spectrophotometry Regulated area: 4 Spectrophotometric and spectral methods |
SOP - 33 (ČSN ISO 11083; ČSN EN ISO 18412) | ||
| 52 | Soils, sludge, sediments, solid waste | Determination of hexavalent chromium (CrVI+) by alkaline digestion by spectrophotometry Regulated area: 4 Spectrophotometric and spectral methods |
SOP - 111 (ČSN EN ISO 15192) | ||
| 53 | Drinking, surface, ground water, bottled water, raw water intended for treatment into drinking water | Determination of humic substances (HL) by spectrophotometry Regulated area: 4 Spectrophotometric and spectral methods |
SOP - 54 (ČSN 75 7536) | ||
| 54 | Water, bathing water, hot water, aqueous leachate | Determination of colour by spectrophotometry Regulated area: 4 Spectrophotometric and spectral methods |
SOP - 55 (ČSN EN ISO 7887, metoda C) | ||
| 55 | Water, bathing water, aqueous leachate | Determination of absorbance of 254 nm wavelength UV radiation Regulated area: 4 Spectrophotometric and spectral methods |
SOP - 56(ČSN 75 7360) | ||
| 56 | Drinking, surface, ground water | Determination of reactive silicon with ammonium molybdate by spectrophotometry and calculation of SiO2 from measured values Regulated area: 4 Spectrophotometric and spectral methods |
SOP - 57 (ČSN 75 7481) | ||
| 57 | Water, aqueous leachate | Determination of nonpolar extractives (NEL) and extractives (EL) by infrared spectrometry method Regulated area: 4 Spectrophotometric and spectral methods |
SOP - 61 (ČSN 75 7505:1998; ČSN 75 7506) | ||
| 58 | Soils, sludge, sediments, solid waste | Determination of nonpolar extractives (NEL) by infrared spectrometry Regulated area: 4 Spectrophotometric and spectral methods |
SOP - 62 (TNV 75 8052) | ||
| 59 | Drinking, ground water | Determination of FeII+ by absorption spectrophotometry with o-phenanthroline and FeIII+ by calculation from measured values Regulated area: 4 Spectrophotometric and spectral methods |
SOP - 40 (ČSN ISO 6332) | ||
| 60 | Surface water, bathing water (natural bathing places) | Determination of chlorophyll-a by spectrophotometry Regulated area: 4 Spectrophotometric and spectral methods |
SOP - 49 (ČSN ISO 10260) | ||
| 61 | Water, bathing water, aqueous leachate | Determination of nitrate by photometric method with 2,6-dimethylphenol in test tubes and nitrate nitrogen (N-NO3) by calculation from measured values Regulated area: 4 Spectrophotometric and spectral methods |
SOP - 104 B (ČSN 75 7455) | ||
| 62 | Drinking, surface, ground and waste water | Determination of anionic surfactants by spectrophotometry Regulated area: 4 Spectrophotometric and spectral methods |
SOP - 89 (ČSN EN 903) | ||
| 63 | Water, aqueous leachate | Determination of anionic surfactants by spectrophotometry – commercial analytical kit Regulated area: 4 Spectrophotometric and spectral methods |
SOP - 118 (Návod firmy Merck) | ||
| 64 | Drinking, surface, ground and waste water | Determination of non-ionic surfactants by spectrophotometry – commercial analytical kit Regulated area: 4 Spectrophotometric and spectral methods |
SOP - 109 (Návod firmy Merck) | ||
| 65 | Drinking, surface, ground and waste water | Determination of dissolved sulphides by spectrophotometry – commercial analytical kit and calculation of sulfane from measured values Regulated area: 4 Spectrophotometric and spectral methods |
SOP - 90 (ČSN ISO 10530; Návod firmy Merck) | ||
| 66 | Water, hot water, bathing water, aqueous leachate | Determination of total organic carbon (TOC), dissolved organic carbon (DOC), and total inorganic carbon (TIC) using an NDIR analyzer, and total carbon (TC) by calculation from measured values Regulated area: 4 Spectrophotometric and spectral methods |
SOP - 79 (ČSN EN 1484) | ||
| 67 | Soils, sediments, sludge, solid waste | Determination of total organic carbon (TOC) and total carbon (TC) using an NDIR analyzer and inorganic carbon (TIC) by calculation from measured values Regulated area: 4 Spectrophotometric and spectral methods |
SOP - 80 (ČSN EN 13137:2002; ČSN ISO 10694; ČSN EN 15936) | ||
| 68 | Emissions, working, indoor and outdoor air (absorbate) | Determination of mass concentration of ammonia by spectrophotometry Regulated area: 4 Spectrophotometric and spectral methods |
SOP - 209 (ČSN 83 4728-1; ČSN 83 4728-4) | ||
| 69 | Emissions, working, indoor and outdoor air (absorbate) | Determination of mass concentration of hydrogen cyanide and cyanide by spectrophotometry Regulated area: 4 Spectrophotometric and spectral methods |
SOP - 211 (ČSN ISO 6703-1:1995; ČSN ISO 6703-2; ČSN 75 7415; EPA Method 9010B) | ||
| 70 | Water, aqueous leachate | Determination of Kjeldahl nitrogen by spectrophotometry Regulated area: 4 Spectrophotometric and spectral methods |
SOP - 125 (ČSN EN 25663; ČSN ISO 7150-1) | ||
| 71 | Emissions, working, indoor and outdoor air (absorbate) | Determination of mass concentration of strong inorganic acids by spectrophotometry Regulated area: 4 Spectrophotometric and spectral methods |
SOP - 212 (Hygienický předpis č. 60, str. 40 - 42, 1981) | ||
| 72 | Water, aqueous leachate | Determination of selected elements using the flame AAS method and calculation of water hardness from measured calcium and magnesium values Silver (Ag) Calcium (Ca) Cobalt (Co) Copper (Cu) Manganese (Mn) Iron (Fe) Nickel (Ni) Magnesium (Mg) Chromium (Cr) Zinc (Zn) Cadmium (Cd) Lead (Pb) Sodium (Na) Potassium (K) Regulated area: 5 Element analysis |
SOP - 41 (ČSN EN ISO 5961; ČSN ISO 7980; ČSN ISO 8288; ČSN 75 7400; ČSN EN 1233) | ||
| 73 | Soils, sediments, sludge, solid waste | Determination of selected elements by flame AAS method Silver (Ag) Calcium (Ca) Cobalt (Co) Copper (Cu) Manganese (Mn) Iron (Fe) Nickel (Ni) Magnesium (Mg) Chromium (Cr) Zinc (Zn) Cadmium (Cd) Lead (Pb) Sodium (Na) Potassium (K) Regulated area: 5 Element analysis |
SOP - 42 (ČSN EN ISO 5961; ČSN ISO 7980; ČSN ISO 8288; ČSN 75 7400; ČSN EN 1233) | ||
| 74 | Working environment, emissions (absorbate, condensate, filter) | Determination of selected elements by flame AAS method Silver (Ag) Calcium (Ca) Cobalt (Co) Copper (Cu) Manganese (Mn) Iron (Fe) Nickel (Ni) Magnesium (Mg) Chromium (Cr) Zinc (Zn) Cadmium (Cd) Lead (Pb) Sodium (Na) Potassium (K) Regulated area: 5 Element analysis |
SOP - 43 (ČSN EN ISO 5961; ČSN ISO 7980; ČSN ISO 8288; ČSN 75 7400; ČSN EN 1233; ČSN EN 14385) | ||
| 75 | Water, bathing water, aqueous leachate | Determination of selected elements by AAS/ETA method Arsenic (As) Antimony (Sb) Barium (Ba) Beryllium (Be) Tin (Sn) Cadmium (Cd) Lead (Pb) Molybdenum (Mo) Selenium (Se) Thallium (Tl) Vanadium (V) Regulated area: 5 Element analysis |
SOP - 44 (ČSN EN ISO 5961; ČSN EN ISO 15586) | ||
| 76 | Soils, sediments, sludge, solid waste | Determination of selected elements by AAS/ETA method Arsenic (As) Antimony (Sb) Barium (Ba) Beryllium (Be) Tin (Sn) Cadmium (Cd) Lead (Pb) Molybdenum (Mo) Selenium (Se) Thallium (Tl) Vanadium (V) Regulated area: 5 Element analysis |
SOP - 45 (ČSN EN ISO 5961; ČSN EN ISO 15586) | ||
| 77 | Working environment, emissions (absorbate, condensate, filter) | Determination of selected elements by AAS/ETA method Arsenic (As) Antimony (Sb) Barium (Ba) Beryllium (Be) Tin (Sn) Cadmium (Cd) Lead (Pb) Molybdenum (Mo) Selenium (Se) Thallium (Tl) Vanadium (V) Regulated area: 5 Element analysis |
SOP - 46 (ČSN EN ISO 5961; ČSN EN ISO 15586; ČSN EN 14385) | ||
| 78 | Water, aqueous leachate, soils, sediments, sludge, solid waste, working environment, emissions (absorbate, condensate, filter) | Determination of mercury by AMA254 analyzer Regulated area: 5 Element analysis |
SOP - 47 (ČSN 75 7440) | ||
| 79 | Water, aqueous leachate | Determination of sodium and potassium by flame emission spectrometry and determination of total mineralization by calculation from measured values Regulated area: 5 Element analysis |
SOP - 48 (ČSN ISO 9964-3; ČSN 75 7358) | ||
| 80 | Water, bathing water, aqueous leachate | Determination of selected elements by ICP/OES method Silver (Ag) Aluminium (Al) Arsenic (As) Barium (Ba) Beryllium (Be) Bismuth (Bi) Boron (B) Cadmium (Cd) Calcium (Ca) Chromium (Cr) Cobalt (Co) Copper (Cu) Potassium (K) Lithium (Li) Iron (Fe) Magnesium (Mg) Manganese (Mn) Molybdenum (Mo) Sodium (Na) Nickel (Ni) Phosphorus (P) Lead (Pb) Rubidium (Rb) Antimony (Sb) Selenium (Se) Tin (Sn) Strontium (Sr) Titanium (Ti) Thallium (Tl) Vanadium (V) Tungsten (W) Zinc (Zn) Regulated area: 5 Element analysis |
SOP - 101 (ČSN EN ISO 11885; Manuál přístroje Shimadzu ICPE-9000) | ||
| 81 | Soils, sediments, sludge, solid waste | Determination of selected elements by ICP/OES method Silver (Ag) Aluminium (Al) Arsenic (As) Barium (Ba) Beryllium (Be) Bismuth (Bi) Boron (B) Cadmium (Cd) Calcium (Ca) Chromium (Cr) Cobalt (Co) Copper (Cu) Potassium (K) Lithium (Li) Iron (Fe) Magnesium (Mg) Manganese (Mn) Molybdenum (Mo) Sodium (Na) Nickel (Ni) Phosphorus (P) Lead (Pb) Rubidium (Rb) Antimony (Sb) Selenium (Se) Tin (Sn) Strontium (Sr) Titanium (Ti) Thallium (Tl) Vanadium (V) Tungsten (W) Zinc (Zn) Regulated area: 5 Element analysis |
SOP - 102 (ČSN EN ISO 11885; ČSN EN 13657; Manuál přístroje Shimadzu ICPE-9000) | ||
| 82 | Working environment, emissions (absorbate, condensate, filter) | Determination of selected elements by ICP/OES method Silver (Ag) Aluminium (Al) Arsenic (As) Barium (Ba) Beryllium (Be) Bismuth (Bi) Boron (B) Cadmium (Cd) Calcium (Ca) Chromium (Cr) Cobalt (Co) Copper (Cu) Potassium (K) Lithium (Li) Iron (Fe) Magnesium (Mg) Manganese (Mn) Molybdenum (Mo) Sodium (Na) Nickel (Ni) Phosphorus (P) Lead (Pb) Rubidium (Rb) Antimony (Sb) Selenium (Se) Tin (Sn) Strontium (Sr) Titanium (Ti) Thallium (Tl) Vanadium (V) Tungsten (W) Zinc (Zn) Regulated area: 5 Element analysis |
SOP - 103 (ČSN EN ISO 11885; Manuál přístroje Shimadzu ICPE-9000; ČSN EN 14385) | ||
| 83 | Water, bathing water, aqueous leachate | Determination of selected elements by ICP/MS method Silver (Ag) Aluminium (Al) Arsenic (As) Barium (Ba) Beryllium (Be) Bismuth (Bi) Boron (B) Cadmium (Cd) Calcium (Ca) Chromium (Cr) Cobalt (Co) Copper (Cu) Potassium (K) Lithium (Li) Iron (Fe) Magnesium (Mg) Manganese (Mn) Molybdenum (Mo) Sodium (Na) Nickel (Ni) Phosphorus (P) Lead (Pb) Rubidium (Rb) Antimony (Sb) Selenium (Se) Tin (Sn) Strontium (Sr) Titanium (Ti) Thallium (Tl) Vanadium (V) Tungsten (W) Zinc (Zn) Uranium (U) Regulated area: 5 Element analysis |
SOP - 113 (ČSN EN ISO 17294-1; ČSN EN ISO 17294-2) | ||
| 84 | Soils, sediments, sludge, solid waste | Determination of selected elements by ICP/MS method Silver (Ag) Aluminium (Al) Arsenic (As) Barium (Ba) Beryllium (Be) Bismuth (Bi) Boron (B) Cadmium (Cd) Calcium (Ca) Chromium (Cr) Cobalt (Co) Copper (Cu) Potassium (K) Lithium (Li) Iron (Fe) Magnesium (Mg) Manganese (Mn) Molybdenum (Mo) Sodium (Na) Nickel (Ni) Phosphorus (P) Lead (Pb) Rubidium (Rb) Antimony (Sb) Selenium (Se) Tin (Sn) Strontium (Sr) Titanium (Ti) Thallium (Tl) Vanadium (V) Tungsten (W) Zinc (Zn) Regulated area: 5 Element analysis |
SOP - 114 (ČSN EN 16171) | ||
| 85 | Working environment, emissions (absorbate, condensate, filter) | Determination of selected elements by ICP/MS method Silver (Ag) Aluminium (Al) Arsenic (As) Barium (Ba) Beryllium (Be) Bismuth (Bi) Boron (B) Cadmium (Cd) Calcium (Ca) Chromium (Cr) Cobalt (Co) Copper (Cu) Potassium (K) Lithium (Li) Iron (Fe) Magnesium (Mg) Manganese (Mn) Molybdenum (Mo) Sodium (Na) Nickel (Ni) Phosphorus (P) Lead (Pb) Rubidium (Rb) Antimony (Sb) Selenium (Se) Tin (Sn) Strontium (Sr) Titanium (Ti) Thallium (Tl) Vanadium (V) Tungsten (W) Zinc (Zn) Regulated area: 5 Element analysis |
SOP - 115 (ČSN EN 16171; Manuál přístroje Shimadzu; ČSN EN 14385) | ||
| 86 | Water, hot water, aqueous leachate | Determination of volatile organic compounds by static head space GC/MS method and calculation of summary parameters from measured values Regulated area: 6 Chromatographic methods |
SOP - 63 (ČSN EN ISO 10301) | ||
| 87 | Soils, sediments, sludge, solid waste | Determination of volatile organic compounds by static head space GC/MS method and calculation of summary parameters from measured values Regulated area: 6 Chromatographic methods |
SOP - 64 (ČSN EN ISO 22155) | ||
| 88 | Soils, sediments, sludge, solid waste, bituminous mixtures | Determination of polycyclic aromatic hydrocarbon by GC/MS method and calculation of summary parameters from measured values Acenaphthene acenaphthylene anthracene benzo/a/anthracene benzo/b/fluoranthene benzo/k/fluoranthene benzo/ghi/perylene benzo/a/pyrene dibenzo/a,h/anthracene phenanthrene fluorene fluoranthene chrysene indeno/1,2,3-cd/pyrene naphthalene pyrene Regulated area: 6 Chromatographic methods |
SOP - 65 (ČSN EN 17503) | ||
| 89 | Water, aqueous leachate | Determination of hydrocarbons C10 to C40 by gas chromatography method GC/FID Regulated area: 6 Chromatographic methods |
SOP - 66 (ČSN EN ISO 9377-2) | ||
| 90 | Soils, sediments, sludge, solid waste | Determination of hydrocarbons C10 to C40 by gas chromatography method GC/FID Regulated area: 6 Chromatographic methods |
SOP - 67 (ČSN EN 14039; ČSN P CEN ISO/TS 16558-2) | ||
| 91 | Water, aqueous leachate | Determination of polychlorinated biphenyls (PCB) by GC/MS method and calculation of summary parameters from measured values PCB-28 PCB-52 PCB-101 PCB-118 PCB-138 PCB-153 PCB-180 Regulated area: 6 Chromatographic methods |
SOP - 68 (ČSN EN ISO 6468) | ||
| 92 | Soils, sediments, sludge, solid waste, petroleum products | Determination of polychlorinated biphenyls (PCB) by GC/MS method and calculation of summary parameters from measured values PCB-28 PCB-52 PCB-101 PCB-118 PCB-138 PCB-153 PCB-180 Regulated area: 6 Chromatographic methods |
SOP - 69 (ČSN EN 61619; ČSN EN 17322; DIN 38407-2: 1993) | ||
| 93 | Water, aqueous leachate | Determination of specified organochlorinated pesticides (OCP) and chlorobenzenes by GC/MS method after liquid/liquid extraction and calculation of summary parameters from measured values Regulated area: 6 Chromatographic methods |
SOP - 70 (ČSN EN ISO 6468) | ||
| 94 | Soils, sediments, sludge, solid waste | Determination of selected pesticides by GC/MS method and calculation of summary parameters from measured values Regulated area: 6 Chromatographic methods |
SOP - 71 (DIN 38407-2: 1993; EPA Method 8270C; EPA Method 8141B; EPA Method 3550C) | ||
| 95 | Soil air | Determination of methane by gas chromatography GC/FID method Regulated area: 6 Chromatographic methods |
SOP - 72 (ČSN EN 482; Supelco, Application Note 10, 1994) | ||
| 96 | Ground water | Determination of light volatile hydrocarbons (methane, ethane, ethene) by gas chromatography GC/FID method methane ethane ethene Regulated area: 6 Chromatographic methods |
SOP - 73 (Determination of Methane in Water – Final Report No. 21/1990) | ||
| 97 | Water, aqueous leachate | Determination of polycyclic aromatic hydrocarbons (PAH) by HPLC method with fluorescence detection and calculation of summary parameters from measured values Acenaphthene anthracene benzo/a/anthracene benzo/b/fluoranthene benzo/k/fluoranthene benzo/ghi/perylene benzo/a/pyrene dibenzo/a,h/anthracene phenanthrene fluorene fluoranthene chrysene indeno/1,2,3-cd/pyrene naphthalene pyrene Regulated area: 6 Chromatographic methods |
SOP - 74 (ČSN EN ISO 17993) | ||
| 98 | Soils, sediments, sludge, solid waste | Determination of polycyclic aromatic hydrocarbons (PAH) by HPLC method with fluorescence detection and calculation of summary parameters from measured values Acenaphthene anthracene benzo/a/anthracene benzo/b/fluoranthene benzo/k/fluoranthene benzo/ghi/perylene benzo/a/pyrene dibenzo/a,h/anthracene phenanthrene fluorene fluoranthene chrysene indeno/1,2,3-cd/pyrene naphthalene pyrene Regulated area: 6 Chromatographic methods |
SOP - 75 (Bulletin laboratorního odboru 2/2003, ÚKZÚZ Brno) | ||
| 99 | Water, aqueous leachate | Determination of polycyclic aromatic hydrocarbons (PAH) by GC/MS method and calculation of summary parameters from measured values Acenaphthene acenaphthylene anthracene benzo/a/anthracene benzo/b/fluoranthene benzo/k/fluoranthene benzo/ghi/perylene benzo/a/pyrene dibenzo/a,h/anthracene phenanthrene fluorene fluoranthene chrysene indeno/1,2,3-cd/pyrene naphthalene pyrene Regulated area: 6 Chromatographic methods |
SOP - 76 (ČSN P ISO/TS 28581) | ||
| 100 | Drinking water, ground, surface and waste water, aqueous leachate | Determination of selected phenol derivatives by GC/MS method and calculation of summary parameters from measured values Regulated area: 6 Chromatographic methods |
SOP - 82 (ČSN EN 12673) | ||
| 101 | Soils, sediments, solid waste | Determination of selected phenol derivatives by GC/MS method and calculation of summary parameters from measured values Regulated area: 6 Chromatographic methods |
SOP - 58 (EPA Method 8041 A; EPA Method 3550 C; EPA Method 3650 B) | ||
| 102 | Ground water, surface water, waste water | Determination of aniline and its selected derivatives by GC/MS method Aniline N-ethylaniline Regulated area: 6 Chromatographic methods |
SOP - 87 (EPA Method 8270 D; EPA Method 3510 C) | ||
| 103 | Drinking water | Determination of selected pesticides by LC/MS/MS method Regulated area: 6 Chromatographic methods |
SOP - 123 (EPA Method 538) | ||
| 104 | Drinking water | Determination of selected alkylphenols by GC/MS/MS method Bisphenol A Regulated area: 6 Chromatographic methods |
SOP - 124 (EPA Method 525.3; ČSN EN ISO 18857-2) | ||
| 105 | Emissions, working, indoor and outdoor air, soil air (sorbent) | Determination of the mass concentration of volatile organic compounds (VOC) by GC/MS method Regulated area: 6 Chromatographic methods |
SOP - 213 (ČSN P CEN/TS 13649) | ||
| 106 | Emissions, working, indoor and outdoor air | Determination of carbonyl compounds after catching on a sorbent with bound 2,4-dinitrophenylhydrazine by HPLC method with UV detection Formaldehyde acetaldehyde acetone acrolein Regulated area: 6 Chromatographic methods |
SOP - 224 (EPA Method TO-5) | ||
| 107 | Drinking water | Determination of selected per- and polyfluoroalkyl substances (PFAS) by liquid chromatography (LC/MS) method and calculation of summary parameters from measured values Perfluorobutanoic acid (PFBA) perfluoroheptanoic acid (PFHpA) perfluorohexanoic acid (PFHxA) perfluoropentanoic acid (PFPeA) perfluorooctanoic acid (PFOA) perfluorononanoic acid (PFNA) perfluorodecanoic acid (PFDA) perfluoroundecanoic acid (PFUdA) perfluorododecanoic acid (PFDoA) perfluorotridecanoic acid (PFTrDA) perfluorobutane sulfonic acid (PFBS) perfluoroheptane sulfonic acid (PFHpS) perfluorohexane sulfonic acid (PFHxS) perfluoropentane sulfonic acid (PFPS) perfluorooctane sulfonic acid (PFOS) perfluorononane sulfonic acid (PFNS) perfluorodecane sulfonic acid (PFDS) perfluoroundecane sulfonic acid (PFUnS) perfluorododecane sulfonic acid (PFDoS) perfluorotridecane sulfonic acid (PFTrS) Regulated area: 6 Chromatographic methods |
SOP - 127 (ČSN EN 17892) | ||
| 108 | Water, hot water, bathing water | Determination of temperature Regulated area: 7 Other chemical and physicochemical methods |
SOP - 01 (ČSN 75 7342) | ||
| 109 | Drinking water, hot water, surface water, waste water, bottled water, bathing water, mineral water | Detection and enumeration of Pseudomonas aeruginosa by membrane filtration method Regulated area: 8 Microbiological tests |
SOP - 300 (ČSN EN ISO 16266) | ||
| 110 | Drinking water, surface water, waste water, bathing water | Detection and enumeration of Clostridium perfringens by membrane filtration method Regulated area: 8 Microbiological tests |
SOP - 301 (Vyhláška č. 252/2004 Sb., příloha č. 6) | ||
| 111 | Drinking water, surface water, waste water, bathing water | Determination of thermotolerant coliform bacteria by membrane filtration method Regulated area: 8 Microbiological tests |
SOP - 302 (ČSN 75 7835) | ||
| 112 | Bathing water, surface water, waste water, hot water | Enumeration of Staphylococcus aureus by membrane filtration method Regulated area: 8 Microbiological tests |
SOP - 303 (ČSN EN ISO 6888-1) | ||
| 113 | Sludge, sand, sediments, composts | Enumeration of indicator microorganisms by direct inoculation method Regulated area: 8 Microbiological tests |
SOP - 304 (AHEM 1/2008; AHEM 7/2001) | ||
| 114 | Drinking water, ground water, surface water | Detection and enumeration of Clostridium perfringens by membrane filtration method Regulated area: 8 Microbiological tests |
SOP - 327 (ČSN EN ISO 14189) | ||
| 115 | Drinking water, bottled water, bathing water, hot water, ground water, surface water, mineral water | Enumeration of culturable microorganisms at 22 °C and 36 °C by direct inoculation in a nutrient agar culture medium Regulated area: 8 Microbiological tests |
SOP - 306 (ČSN EN ISO 6222) | ||
| 116 | Drinking water, surface water, waste water, bathing water | Detection and enumeration of coliform bacteria by membrane filtration method Regulated area: 8 Microbiological tests |
SOP - 307 (ČSN 75 7837) | ||
| 117 | Drinking water, bottled water, bathing water, ground water, surface water, waste water, mineral water | Detection and enumeration of intestinal enterococci by membrane filtration method Regulated area: 8 Microbiological tests |
SOP - 308 (ČSN EN ISO 7899-2) | ||
| 118 | Surface, ground water | Detection and enumeration of mesophilic bacteria by direct inoculation in a nutrient agar culture medium Regulated area: 8 Microbiological tests |
SOP - 309 (ČSN 75 7841) | ||
| 119 | Surface, ground water | Detection and enumeration of psychrophilic bacteria by direct inoculation in a nutrient agar culture medium Regulated area: 8 Microbiological tests |
SOP - 310 (ČSN 75 7842) | ||
| 120 | Drinking water, bottled water, water at the outlet of water treatment plants, bathing water, mineral water, hot water | Detection and enumeration of Escherichia coli and coliform bacteria by membrane filtration method Regulated area: 8 Microbiological tests |
SOP - 311 (ČSN EN ISO 9308-1) | ||
| 121 | Bottled water, bathing water, waste water, ground water, mineral water | Detection and enumeration of sulfite-reducing anaerobes (clostridia) by membrane filtration method Regulated area: 8 Microbiological tests |
SOP - 312 (ČSN EN 26461-2) | ||
| 122 | Drinking water, hot water, bathing water | Detection and enumeration of Legionella spp. by membrane filtration and direct inoculation method Regulated area: 8 Microbiological tests |
SOP - 313 (ČSN EN ISO 11731) | ||
| 123 | Drinking water, surface water, ground water | Determination of abioseston by microscopic method Regulated area: 9 Biological, ecotoxicological, and sensory tests |
SOP - 316 (ČSN 75 7713) | ||
| 124 | Drinking water, bottled water, surface water, ground water | Determination of bioseston by microscopic method Regulated area: 9 Biological, ecotoxicological, and sensory tests |
SOP - 317 (ČSN 75 7712) | ||
| 125 | Soils, waste, water, aqueous leachate | Determination of the inhibition of the mobility of Daphnia magna Regulated area: 9 Biological, ecotoxicological, and sensory tests |
SOP - 351 (ČSN EN ISO 6341) | ||
| 126 | Soils, waste, water, aqueous leachate | Fresh water green algal growth inhibition test with Desmodesmus subspicatus Regulated area: 9 Biological, ecotoxicological, and sensory tests |
SOP - 352 (ČSN EN ISO 8692) | ||
| 127 | Soils, waste, water, aqueous leachate | Sinapis alba root growth inhibition test Regulated area: 9 Biological, ecotoxicological, and sensory tests |
SOP - 353 (Metodický pokyn 8, Věstník MŽP ČR, roč. XVII, č. 4/2007) | ||
| 128 | Soils, waste, water, aqueous leachate | Test of the inhibitory effect on the light emission of luminescent bacteria Aliivibrio fischeri Regulated area: 9 Biological, ecotoxicological, and sensory tests |
SOP - 354 (ČSN EN ISO 11348-2; ČSN EN ISO 11348-3; Vyhláška č. 273/2021 Sb.; Vyhláška č. 8/2021 Sb.) | ||
| 129 | Soils, waste | Test of root growth inhibition in lettuce Lactuca sativa Regulated area: 9 Biological, ecotoxicological, and sensory tests |
SOP - 355 (ČSN EN ISO 11269-1; Vyhláška č. 273/2021 Sb.; Vyhláška č. 8/2021 Sb.) | ||
| 130 | Drinking water, bottled water, hot water | Determination of odour and flavour – preliminary sensory tests Regulated area: 9 Biological, ecotoxicological, and sensory tests |
SOP - 05 (ČSN EN 1622; ČSN 75 7340) | ||
| 131 | Bathing water | Determination of transparency Regulated area: 9 Biological, ecotoxicological, and sensory tests |
SOP - 08 (ČSN 75 7340) | ||
| 132 | Drinking water, bottled water, ground water | Determination of radon222 activity concentration by gamma radiation measurement Regulated area: 10 Radiochemical tests |
SOP - 50 (ČSN 75 7624) | ||
| 133 | Water | Determination of gross alpha activity concentration by scintillation, corrected gross alpha activity concentration by calculation from measured values and calculation of total indicative dose Regulated area: 10 Radiochemical tests |
SOP - 121 (ČSN 75 7611; Doporučení SÚJB DR-RO-5.1, 2017) | ||
| 134 | Water | Determination of gross beta activity by the measurement of evaporation residue with proportional detector and gross beta activity with potassium 40 correction by calculation from the measured values Regulated area: 10 Radiochemical tests |
SOP - 122 (ČSN 75 7612; Doporučení SÚJB DR-RO-5.1, 2017) | ||
| 135 | Drinking water, bottled water | Drinking water sampling Regulated area: Sampling |
SOP-V-01 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-5; ČSN EN ISO 5667-14; ČSN EN ISO 19458; Vyhláška č. 252/2004 Sb.) | ||
| 136 | Industrial and sewage waste water | Waste water sampling, manual and by automatic sampler Regulated area: Sampling |
SOP-V-02 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-10; ČSN EN ISO 5667-14) | ||
| 137 | Dewatered sludge from WWTP | Manual sampling of sludge from WWTP Regulated area: Sampling |
SOP-V-03 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-13; ČSN EN ISO 5667-15) | ||
| 138 | Soils, solid waste | Sampling of soils and solid waste Regulated area: Sampling |
SOP-V-04 (TNI CEN/TR 15310-1; TNI CEN/TR 15310-2; TNI CEN/TR 15310-3; TNI CEN/TR 15310-4; TNI CEN/TR 15310-5) | ||
| 139 | Sediments | Sampling of sediments Regulated area: Sampling |
SOP-V-05 (ČSN EN ISO 5667-1; ČSN ISO 5667-12; ČSN EN ISO 5667-14; ČSN EN ISO 5667-15) | ||
| 140 | Ground water | Ground water sampling, manual and with pressure pump Regulated area: Sampling |
SOP-V-06 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-11; ČSN EN ISO 5667-14) | ||
| 141 | Surface water | Manual sampling of surface water Regulated area: Sampling |
SOP-V-07 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-6; ČSN ISO 5667-4; ČSN EN ISO 5667-14) | ||
| 142 | Artificial bathing places | Bathing water sampling Regulated area: Sampling |
SOP-V-08 (ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN EN ISO 5667-14; ČSN EN ISO 19458; Vyhláška č. 238/2011 Sb.) | ||
| 143 | Natural bathing places | Sampling of water from natural bathing places Regulated area: Sampling |
SOP-V-09 (ČSN EN ISO 19458; ČSN EN ISO 5667-1; ČSN EN ISO 5667-3; ČSN ISO 5667-4; ČSN EN ISO 5667-6; ČSN EN ISO 5667-14; ČSN 75 7712; ČSN 75 7717; ČSN 75 7340; Vyhláška č. 238/2011 Sb.) | ||
| 144 | Soil air | Sampling of soil air Regulated area: Sampling |
SOP-V-29 (Metodický pokyn MŽP Vzorkovací práce v sanační geologii, kap. III.10, Odběr vzorků ovzduší a vzdušin, 2006) | ||
| Dražkovice workplace | |||||
| 145 | Emissions, working, indoor and outdoor air (filters) | Determination of mass concentration of solid pollutants and dust by gravimetry Regulated area: 1 Gravimetric methods |
SOP - 206 (ČSN EN 13284-1; ČSN EN ISO 16911-1; ČSN EN 15259; NV č. 361/2007 Sb.) | ||
| 146 | Emissions | Determination of the volume concentration of oxygen by automatic analyzer (paramagnetic method) Regulated area: 3 Electrochemical methods |
SOP - 203 (ČSN EN 14789) | ||
| 147 | Emissions | Determination of the mass concentration of gaseous pollutants using automated NOx, CO, SO2 analyzers (NDIR) Regulated area: 4 Spectrophotometric and spectral methods |
SOP - 202 A (ČSN ISO 10849; ČSN EN 15058; ČSN ISO 7935) | ||
| 148 | Soil air | Determination of methane (CH4) by automated analyser (NDIR) Regulated area: 4 Spectrophotometric and spectral methods |
SOP - 205 (Návod k obsluze Optima 7 Biogas) | ||
| 149 | Emissions | Determination of mass concentration of gaseous pollutants (NOx) by automatic analyzers (chemiluminescence) Regulated area: 4 Spectrophotometric and spectral methods |
SOP - 202 B (ČSN EN 14792; ČSN ISO 10849) | ||
| 150 | Construction materials, materials from construction | Preliminary detection of asbestos by near-infrared spectroscopy (NIR) method Regulated area: 4 Spectrophotometric and spectral methods |
SOP - 229 (Návod k použití firmy Thermo Scientific) | ||
| 151 | Construction materials, materials from construction | Qualitative determination of inorganic fibres, including asbestos fibres, by scanning electron microscope with EDX analyzer - SEM/EDX Regulated area: 4 Spectrophotometric and spectral methods |
SOP - 227 (VDI 3866 Part V) | ||
| 152 | Indoor, outdoor, workplace air | Determination of numerical concentration of inorganic fibres, including asbestos fibres, in air by scanning electron microscope with EDX analyzer – SEM/EDX Regulated area: 4 Spectrophotometric and spectral methods |
SOP - 228 (ČSN EN ISO 16000-7; ISO 14966; VDI 3492; NV č. 361/2007 Sb.) | ||
| 153 | Emissions (filter, absorbate) | Determination of mass concentration of elements by calculation from measured values (As, Cd, Be, Cr, Co, Ni, Tl, Se, Te, Sb, Sn, Mn, Cu, Pb, V, Zn, Al, Hg, CrVI+) Regulated area: 5 Element analysis |
SOP - 214 (ČSN EN 13211; ČSN EN 14385; EPA Method 29; EPA Method 0061) | ||
| 154 | Emissions | Determination of velocity and volume flow rate Regulated area: 7 Other chemical and physicochemical methods |
SOP - 200 (ČSN ISO 10780; ČSN EN ISO 16911-1; ČSN EN 15259) | ||
| 155 | Emissions | Determination of water vapour in ducts (by condensation, condensation adsorption method, capacitance detector) Regulated area: 7 Other chemical and physicochemical methods |
SOP - 201 (ČSN EN 14790) | ||
| 156 | Emissions | Determination of total mass concentration of organic compounds expressed as total organic carbon (TOC) by automatic analyzers (FID) Regulated area: 7 Other chemical and physicochemical methods |
SOP - 204 (ČSN EN 12619) | ||
| 157 | Emissions (filter, condensate, absorbate) | Determination of the mass concentration of persistent organic compounds (POPs) by calculation from measured values (PCDD/PCDF, PCB, PAH) Regulated area: 7 Other chemical and physicochemical methods |
SOP - 215 (ČSN EN 1948-3; ČSN EN 1948-4+A1; ISO 11338-1:2003; ISO 11338-2:2003) | ||
| 158 | Emissions, working and indoor air | Determination of the mass concentration of gases and vapours taken into liquid by the calculation from measured values Regulated area: 7 Other chemical and physicochemical methods |
SOP - 216 (ČSN EN 1911; ČSN P CEN/TS 17340; ČSN 83 4728-1; Nařízení vlády č. 361/2007 Sb.; ČSN EN 482; ČSN EN 689+AC; ČSN EN ISO 16017-1) | ||
| 159 | Emissions, working and indoor air | Determination of mass concentration of organic compounds by capture on a solid sorbent by calculation from measured values Regulated area: 7 Other chemical and physicochemical methods |
SOP - 217 (ČSN P CEN/TS 13649; Nařízení vlády č. 361/2007 Sb.; ČSN EN 482; ČSN EN 689+AC; ČSN EN ISO 16017-1) | ||
| 160 | Working, indoor and outdoor air | Measurement of microclimatic conditions (resulting temperature of a spherical thermometer, air temperature, relative air humidity, air flow velocity, operating temperature) Regulated area: 7 Other chemical and physicochemical methods |
SOP - 218 (ČSN EN ISO 7726; Věstník MZ ČR č. 8/2013; ČSN EN ISO 7730) | ||
| 161 | Emissions, working, indoor and outdoor air, soil air | Semiquantitative determination of analytes by means of detection tubes Regulated area: 7 Other chemical and physicochemical methods |
SOP - 223 (ČSN EN ISO 17621; Návody firmy Gastec a Dräger) | ||
| 162 | Working environment | Measurement of noise Regulated area: 11 Physical tests |
SOP - 220 (Věstník MZ ČR č. 4/2013; ČSN ISO 1996-1; ČSN EN ISO 9612) | ||
| 163 | Non-working environment | Measurement of noise Regulated area: 11 Physical tests |
SOP - 221 (OVZ-32.0-19.2.2007/6306; TP 189; Věstník MZ ČR částka 14, 2023; ČSN ISO 1996-1; ČSN ISO 1996-2; ČSN ISO 9613-2; ČSN EN ISO 11201; ČSN EN ISO 11202) | ||
| 164 | Noise sources | Determination of the sound power level Regulated area: 11 Physical tests |
SOP - 222 (ČSN ISO 1996-1; ČSN EN ISO 3744; ČSN EN ISO 3746; ČSN EN ISO 3747) | ||
| 165 | Working environment | Measurement of vibration Regulated area: 11 Physical tests |
SOP - 225 (ČSN EN ISO 5349-1; ČSN EN ISO 5349-2; ČSN ISO 5348; ČSN ISO 2631-1; ČSN EN 14253+A1; ČSN EN ISO 8041-1; Věstník MZ ČR č. 4/2013) | ||
| 166 | Indoor environment | Measurement of electrical lighting Regulated area: 11 Physical tests |
SOP - 226 (ČSN EN 12665; ČSN 36 0011-1; ČSN 36 0011-3; ČSN 36 0011-4; ČSN EN 12464-1; ČSN EN 12464-2; ČSN EN 12193; ČSN EN 1838 ed. 2; TNI 36 0450; TNI 36 0451) | ||
| 167 | Construction materials, materials from construction | Sampling of building materials for qualitative determination of asbestos and other fibres Regulated area: Sampling |
SOP-V-10 (VDI 3866, Part1) | ||
| 168 | Emissions | Sampling of gases and vapours by absorption into liquid Regulated area: Sampling |
SOP-V-20 (ČSN EN 1911; ČSN 83 4728-1; ČSN 83 4728-2; ČSN P CEN/TS 17340; ČSN EN 14791; ČSN 83 4711-1; ČSN 83 4711-2; Hygienický předpis č. 52, str. 40; ČSN 83 4712-1; ČSN 83 4712-2; ČSN ISO 6703-2) | ||
| 169 | Emissions | Sampling of gases and vapours by sorption on a solid sorbent Regulated area: Sampling |
SOP-V-21 (ČSN P CEN/TS 13649) | ||
| 170 | Emissions | Sampling of solid pollutants (isokinetic sampling with automatic isokinetic control) Regulated area: Sampling |
SOP-V-22 (ČSN EN 13284-1; ČSN EN ISO 16911-1) | ||
| 171 | Emissions | Sampling of solid pollutants (isokinetic sampling with manual isokinetic control) Regulated area: Sampling |
SOP-V-23 (ČSN EN 13284-1; ČSN EN ISO 16911-1) | ||
| 172 | Emissions | Sampling for determination of heavy metals – isokinetic sampling with automatic or manual isokinetic control and absorption into liquid Regulated area: Sampling |
SOP-V-24 (ČSN EN 13284-1; ČSN EN 14385; ČSN EN 13211; EPA Method 29; EPA Method 0061) | ||
| 173 | Emissions | Sampling for determination of persistent organic pollutants POPs – isokinetic sampling with automatic or manual isokinetic control, filter-condenser method Regulated area: Sampling |
SOP-V-25 (ČSN EN 13284-1; ČSN EN 1948-1; ČSN EN 1948-4+A1; ISO 11338-1:2003) | ||
| 174 | Working, indoor and outdoor air | Air sampling for determination of gases and vapours Regulated area: Sampling |
SOP-V-26 (ČSN EN 482; ČSN EN 689+AC; ČSN EN ISO 16000-1; ČSN EN ISO 16000-2; ČSN EN ISO 16000-5; ČSN EN ISO 16000-11; ČSN EN ISO 16017-1; NV č. 361/2007 Sb.; Vyhláška č. 43/2025 Sb.) | ||
| 175 | Working, indoor and outdoor air | Air sampling for determination of dust and aerosols Regulated area: Sampling |
SOP-V-27 (ČSN EN 481; ČSN EN 482; ČSN EN 689+AC; ČSN EN ISO 16000-1; NV č. 361/2007 Sb.; Vyhláška č. 43/2025 Sb.) | ||
| 176 | Working, indoor and outdoor air | Air sampling for determination of numerical concentration of mineral fibres including asbestos Regulated area: Sampling |
SOP-V-30 (ČSN EN ISO 16000-7; NV č. 361/2007 Sb.; Vyhláška č. 43/2025 Sb.) | ||
Reference standards (433)
AHEM 1/2008
AHEM 7/2001
Aplikační list č. 24 firmy Villa Labeco, s.r.o.
Bulletin laboratorního odboru 2/2003, ÚKZÚZ Brno
DIN 38407-2: 1993
DIN 38414-17:2014
Determination of Methane in Water – Final Report No. 21/1990
Doporučení SÚJB DR-RO-5.1, 2017
EPA Method 0061
EPA Method 29
EPA Method 3510 C
EPA Method 3550 C
EPA Method 3550C
EPA Method 3650 B
EPA Method 420.1
EPA Method 525.3
EPA Method 538
EPA Method 8041 A
EPA Method 8141B
EPA Method 8270 D
EPA Method 8270C
EPA Method 9010B
EPA Method 9013A
EPA Method TO-5
Firemní manuál LABTECH
Horáková M. a kol.: Chemické a fyzikální metody analýzy vod, Praha 1986
Hygienický předpis č. 52, str. 40
Hygienický předpis č. 60, str. 40 - 42, 1981
ISO 11338-1:2003
ISO 11338-2:2003
ISO 14966
JPP ÚKZÚZ Brno 2010
JPP ÚKZÚZ Brno 2020
JPP ÚKZÚZ, Brno 2011
Manuál přístroje Shimadzu
Manuál přístroje Shimadzu ICPE-9000
Metodický pokyn 8, Věstník MŽP ČR, roč. XVII, č. 4/2007
Metodický pokyn MŽP Vzorkovací práce v sanační geologii, kap. III.10, Odběr vzorků ovzduší a vzdušin, 2006
NV č. 361/2007 Sb.
Nařízení vlády č. 361/2007 Sb.
Návod firmy HACH
Návod firmy HANNA
Návod firmy LABTECH
Návod firmy Lovibond
Návod firmy Merck
Návod k obsluze Optima 7 Biogas
Návod k použití firmy Thermo Scientific
Návody firmy Gastec a Dräger
OVZ-32.0-19.2.2007/6306
Pitter P. a kol.: Hydrochemie, 4. vydání, VŠCHT Praha 2009
SOP - 01
SOP - 02
SOP - 03 A
SOP - 03 B
SOP - 05
SOP - 06 A
SOP - 06 B
SOP - 07
SOP - 08
SOP - 09 A
SOP - 09 B
SOP - 10 A
SOP - 10 B
SOP - 101
SOP - 102
SOP - 103
SOP - 104 B
SOP - 109
SOP - 11
SOP - 111
SOP - 113
SOP - 114
SOP - 115
SOP - 118
SOP - 119
SOP - 12 A
SOP - 12 B
SOP - 121
SOP - 122
SOP - 123
SOP - 124
SOP - 125
SOP - 126
SOP - 127
SOP - 13
SOP - 14
SOP - 15
SOP - 16
SOP - 17
SOP - 18
SOP - 19
SOP - 20
SOP - 200
SOP - 201
SOP - 202 A
SOP - 202 B
SOP - 203
SOP - 204
SOP - 205
SOP - 206
SOP - 207
SOP - 208
SOP - 209
SOP - 21
SOP - 211
SOP - 212
SOP - 213
SOP - 214
SOP - 215
SOP - 216
SOP - 217
SOP - 218
SOP - 219
SOP - 22
SOP - 220
SOP - 221
SOP - 222
SOP - 223
SOP - 224
SOP - 225
SOP - 226
SOP - 227
SOP - 228
SOP - 229
SOP - 23
SOP - 24
SOP - 25
SOP - 26
SOP - 27
SOP - 28
SOP - 29
SOP - 30
SOP - 300
SOP - 301
SOP - 302
SOP - 303
SOP - 304
SOP - 306
SOP - 307
SOP - 308
SOP - 309
SOP - 31
SOP - 310
SOP - 311
SOP - 312
SOP - 313
SOP - 316
SOP - 317
SOP - 32
SOP - 327
SOP - 33
SOP - 34
SOP - 35
SOP - 351
SOP - 352
SOP - 353
SOP - 354
SOP - 355
SOP - 36
SOP - 37
SOP - 38
SOP - 39 A
SOP - 39 B
SOP - 40
SOP - 41
SOP - 42
SOP - 43
SOP - 44
SOP - 45
SOP - 46
SOP - 47
SOP - 48
SOP - 49
SOP - 50
SOP - 52
SOP - 53
SOP - 54
SOP - 55
SOP - 56
SOP - 57
SOP - 58
SOP - 61
SOP - 62
SOP - 63
SOP - 64
SOP - 65
SOP - 66
SOP - 67
SOP - 68
SOP - 69
SOP - 70
SOP - 71
SOP - 72
SOP - 73
SOP - 74
SOP - 75
SOP - 76
SOP - 79
SOP - 80
SOP - 81
SOP - 82
SOP - 87
SOP - 89
SOP - 90
SOP - 95
SOP - 96
SOP-V-01
SOP-V-02
SOP-V-03
SOP-V-04
SOP-V-05
SOP-V-06
SOP-V-07
SOP-V-08
SOP-V-09
SOP-V-10
SOP-V-20
SOP-V-21
SOP-V-22
SOP-V-23
SOP-V-24
SOP-V-25
SOP-V-26
SOP-V-27
SOP-V-29
SOP-V-30
Supelco, Application Note 10, 1994
TNI 36 0450
TNI 36 0451
TNI 75 7531
TNI CEN/TR 15310-1
TNI CEN/TR 15310-2
TNI CEN/TR 15310-3
TNI CEN/TR 15310-4
TNI CEN/TR 15310-5
TNV 75 8052
TP 189
VDI 3492
VDI 3866 Part V
VDI 3866, Part1
Vyhláška č. 238/2011 Sb.
Vyhláška č. 252/2004 Sb.
Vyhláška č. 252/2004 Sb., příloha č. 6
Vyhláška č. 273/2021 Sb.
Vyhláška č. 43/2025 Sb.
Vyhláška č. 8/2021 Sb.
Věstník MZ ČR č. 4/2013
Věstník MZ ČR č. 8/2013
Věstník MZ ČR částka 14, 2023
ČSN 36 0011-1
ČSN 36 0011-3
ČSN 36 0011-4
ČSN 75 7340
ČSN 75 7342
ČSN 75 7346
ČSN 75 7347
ČSN 75 7350
ČSN 75 7358
ČSN 75 7360
ČSN 75 7367
ČSN 75 7372
ČSN 75 7373
ČSN 75 7400
ČSN 75 7415
ČSN 75 7440
ČSN 75 7455
ČSN 75 7477
ČSN 75 7481
ČSN 75 7505:1998
ČSN 75 7506
ČSN 75 7536
ČSN 75 7611
ČSN 75 7612
ČSN 75 7624
ČSN 75 7712
ČSN 75 7713
ČSN 75 7717
ČSN 75 7835
ČSN 75 7837
ČSN 75 7841
ČSN 75 7842
ČSN 83 4711-1
ČSN 83 4711-2
ČSN 83 4712-1
ČSN 83 4712-2
ČSN 83 4728-1
ČSN 83 4728-2
ČSN 83 4728-4
ČSN EN 12193
ČSN EN 1233
ČSN EN 12464-1
ČSN EN 12464-2
ČSN EN 12619
ČSN EN 12665
ČSN EN 12673
ČSN EN 13137:2002
ČSN EN 13211
ČSN EN 13284-1
ČSN EN 13342
ČSN EN 13654-1
ČSN EN 13657
ČSN EN 14039
ČSN EN 14253+A1
ČSN EN 14385
ČSN EN 14789
ČSN EN 14790
ČSN EN 14791
ČSN EN 14792
ČSN EN 1484
ČSN EN 15058
ČSN EN 15259
ČSN EN 15934
ČSN EN 15935
ČSN EN 15936
ČSN EN 16166
ČSN EN 16169
ČSN EN 16171
ČSN EN 1622
ČSN EN 17322
ČSN EN 17503
ČSN EN 17892
ČSN EN 1838 ed. 2
ČSN EN 1911
ČSN EN 1948-1
ČSN EN 1948-3
ČSN EN 1948-4+A1
ČSN EN 25663
ČSN EN 26461-2
ČSN EN 26777
ČSN EN 27888
ČSN EN 481
ČSN EN 482
ČSN EN 61619
ČSN EN 689+AC
ČSN EN 872
ČSN EN 903
ČSN EN ISO 10301
ČSN EN ISO 10390
ČSN EN ISO 11201
ČSN EN ISO 11202
ČSN EN ISO 11269-1
ČSN EN ISO 11348-2
ČSN EN ISO 11348-3
ČSN EN ISO 11731
ČSN EN ISO 11885
ČSN EN ISO 14189
ČSN EN ISO 15192
ČSN EN ISO 15586
ČSN EN ISO 16000-1
ČSN EN ISO 16000-11
ČSN EN ISO 16000-2
ČSN EN ISO 16000-5
ČSN EN ISO 16000-7
ČSN EN ISO 16017-1
ČSN EN ISO 16266
ČSN EN ISO 16911-1
ČSN EN ISO 17294-1
ČSN EN ISO 17294-2
ČSN EN ISO 17621
ČSN EN ISO 17993
ČSN EN ISO 18412
ČSN EN ISO 18857-2
ČSN EN ISO 19458
ČSN EN ISO 22155
ČSN EN ISO 3744
ČSN EN ISO 3746
ČSN EN ISO 3747
ČSN EN ISO 5349-1
ČSN EN ISO 5349-2
ČSN EN ISO 5667-1
ČSN EN ISO 5667-13
ČSN EN ISO 5667-14
ČSN EN ISO 5667-15
ČSN EN ISO 5667-3
ČSN EN ISO 5667-6
ČSN EN ISO 5814
ČSN EN ISO 5815-1
ČSN EN ISO 5961
ČSN EN ISO 6222
ČSN EN ISO 6341
ČSN EN ISO 6468
ČSN EN ISO 6888-1
ČSN EN ISO 7027-1
ČSN EN ISO 7726
ČSN EN ISO 7730
ČSN EN ISO 7887, metoda C
ČSN EN ISO 7899-2
ČSN EN ISO 8041-1
ČSN EN ISO 8467
ČSN EN ISO 8692
ČSN EN ISO 9308-1
ČSN EN ISO 9377-2
ČSN EN ISO 9562
ČSN EN ISO 9612
ČSN EN ISO 9963-1
ČSN ISO 10260
ČSN ISO 10359-1
ČSN ISO 10523
ČSN ISO 10530
ČSN ISO 10694
ČSN ISO 10780
ČSN ISO 10849
ČSN ISO 11083
ČSN ISO 11261
ČSN ISO 15705
ČSN ISO 17289
ČSN ISO 1996-1
ČSN ISO 1996-2
ČSN ISO 2631-1
ČSN ISO 5348
ČSN ISO 5667-10
ČSN ISO 5667-11
ČSN ISO 5667-12
ČSN ISO 5667-4
ČSN ISO 5667-5
ČSN ISO 6058
ČSN ISO 6059
ČSN ISO 6060
ČSN ISO 6332
ČSN ISO 6439
ČSN ISO 6703-1:1995
ČSN ISO 6703-2
ČSN ISO 7150-1
ČSN ISO 7935
ČSN ISO 7980
ČSN ISO 8288
ČSN ISO 9297
ČSN ISO 9613-2
ČSN ISO 9964-3
ČSN P CEN ISO/TS 16558-2
ČSN P CEN/TS 13649
ČSN P CEN/TS 17340
ČSN P ISO/TS 28581