🇵🇱 TELE-COM Sp. z o. o. PL
环境材料与高分子
TELE-COM Sp. z o. o. 是由 PCA 认可的实验室,认可编号 AB 529(Poznań,波兰)。认可范围涵盖 31 项检测方法,涉及以下领域:环境、材料与高分子。检测对象包括:Environment – electromagnetic field in the vicinity of radiocommuni…、Workplace environment − electromagnetic field from equipment used i…、Workplace environment − electromagnetic field originating from indu…、Workplace environment − electromagnetic field originating from radi…。最常用的技术:直接测量法。
要点速览
- 认可编号: PCA AB 529
- 认可范围内方法数: 31
- 检测对象种类: 9
- 所用技术数: 1
- 城市: Poznań, 波兰
- 认可编号
- AB 529
- 认可机构
- PCA
- 地址
- LABORATORIUM BADAWCZE, ul. Jawornicka 8, 60-968 Poznań
- 城市
- Poznań, 波兰
该实验室检测什么 (9)
- Environment – electromagnetic field in the vicinity of radiocommunication and radionavigation installations (broadband measurements) — 5 项方法
- Workplace environment − electromagnetic field from equipment used in medical technology: - surgical diathermy units - physiotherapy diathermy units — 4 项方法
- Workplace environment − electromagnetic field originating from industrial installations and equipment: - arc welding equipment - resistance welding machines - dielectric heating equipment - induction heating equipment - industrial microwave furnaces, heaters and dryers, - equipment for the production and processing of plastics - soldering equipment - electrical discharge machines - resistance and arc furnaces - electric generators and motors - inverters - inductive metal detectors — 4 项方法
- Workplace environment − electromagnetic field originating from radiocommunication and anti-theft systems: - handheld and cordless radiotelephones, short range wireless terminals and devices, body-worn and vehicle-mounted radio stations (radiotelephones) - radar systems: stationary / non-stationary field - equipment emitting an electromagnetic field for purposes other than communication or location — 4 项方法
- Workplace environment − electromagnetic field in the workspace during the use of magnetotherapy or magnetostimulation devices — 3 项方法
- Workplace environment − electromagnetic field in the workspace during the use of power systems and alternating current electrical supply installations in the power industry — 3 项方法
- Workplace environment − electromagnetic field in the workspace during the use of transmitting devices of radiocommunication systems — 3 项方法
- 环境 — 变电站与输电线路周围的电磁场 — 3 项方法
- Environment – electromagnetic field in the vicinity of radar installations (broadband measurements) — 2 项方法
所用检测技术 (1)
- 直接测量法 — 21 项方法
认可范围 — 项检测方法 (31)
| 序号 | 检测对象 | 方法 / 参数 | 技术 | 依据文件 | |
|---|---|---|---|---|---|
| 检测方法 | |||||
| 1 | Workplace environment − electromagnetic field originating from industrial installations and equipment: - arc welding equipment - resistance welding machines - dielectric heating equipment - induction heating equipment - industrial microwave furnaces, heaters and dryers, - equipment for the production and processing of plastics - soldering equipment - electrical discharge machines - resistance and arc furnaces - electric generators and motors - inverters - inductive metal detectors | 电场强度: w zakresie częstotliwości od 5 Hz do 100 kHz 范围 1 V/m – 50 kV/m w zakresie częstotliwości od 0,1 MHz do 6 GHz 范围 (0,8 – 1000) V/m |
直接测量法 | PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego IMB edycja 4 z dnia 05.06.2025 r. | |
| 2 | Workplace environment − electromagnetic field originating from industrial installations and equipment: - arc welding equipment - resistance welding machines - dielectric heating equipment - induction heating equipment - industrial microwave furnaces, heaters and dryers, - equipment for the production and processing of plastics - soldering equipment - electrical discharge machines - resistance and arc furnaces - electric generators and motors - inverters - inductive metal detectors | 磁场强度: w zakresie częstotliwości od 0,1 MHz do 30 MHz 范围 (0,01 – 16) A/m w zakresie częstotliwości od 30 MHz do 1000 MHz 范围 (0,01 – 10) A/m |
直接测量法 | PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego IMB edycja 4 z dnia 05.06.2025 r. | |
| 3 | Workplace environment − electromagnetic field originating from industrial installations and equipment: - arc welding equipment - resistance welding machines - dielectric heating equipment - induction heating equipment - industrial microwave furnaces, heaters and dryers, - equipment for the production and processing of plastics - soldering equipment - electrical discharge machines - resistance and arc furnaces - electric generators and motors - inverters - inductive metal detectors | 磁感应强度: w zakresie częstotliwości od 5 Hz do 500 Hz 范围 1 μT – 20 mT w zakresie częstotliwości od 500 Hz do 600 kHz 范围 (30 nT – 20 mT) |
直接测量法 | PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego IMB edycja 4 z dnia 05.06.2025 r. | |
| 4 | Workplace environment − electromagnetic field originating from industrial installations and equipment: - arc welding equipment - resistance welding machines - dielectric heating equipment - induction heating equipment - industrial microwave furnaces, heaters and dryers, - equipment for the production and processing of plastics - soldering equipment - electrical discharge machines - resistance and arc furnaces - electric generators and motors - inverters - inductive metal detectors | 磁场强度: w zakresie częstotliwości od 5 Hz do 600 kHz w zakresie częstotliwości od 0,8 GHz do 6 GHz (计算得出) |
PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego IMB edycja 4 z dnia 05.06.2025 r. | ||
| 5 | Workplace environment − electromagnetic field originating from radiocommunication and anti-theft systems: - handheld and cordless radiotelephones, short range wireless terminals and devices, body-worn and vehicle-mounted radio stations (radiotelephones) - radar systems: stationary / non-stationary field - equipment emitting an electromagnetic field for purposes other than communication or location | 电场强度: w zakresie częstotliwości od 0,1 MHz do 6 GHz 范围 (0,8 – 1000) V/m w zakresie częstotliwości od 6 GHz do 90 GHz 范围 (0,8 – 300) V/m |
直接测量法 | PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego IMB edycja 4 z dnia 05.06.2025 r. | |
| 6 | Workplace environment − electromagnetic field originating from radiocommunication and anti-theft systems: - handheld and cordless radiotelephones, short range wireless terminals and devices, body-worn and vehicle-mounted radio stations (radiotelephones) - radar systems: stationary / non-stationary field - equipment emitting an electromagnetic field for purposes other than communication or location | 磁场强度: w zakresie częstotliwości od 0,1 MHz do 30 MHz 范围 (0,01 – 16) A/m w zakresie częstotliwości od 30 MHz do 1000 MHz 范围 (0,01 – 10) A/m |
直接测量法 | PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego IMB edycja 4 z dnia 05.06.2025 r. | |
| 7 | Workplace environment − electromagnetic field originating from radiocommunication and anti-theft systems: - handheld and cordless radiotelephones, short range wireless terminals and devices, body-worn and vehicle-mounted radio stations (radiotelephones) - radar systems: stationary / non-stationary field - equipment emitting an electromagnetic field for purposes other than communication or location | 磁感应强度: w zakresie częstotliwości od 500 Hz do 600 kHz 范围 (30 nT – 20 mT) |
直接测量法 | PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego IMB edycja 4 z dnia 05.06.2025 r. | |
| 8 | Workplace environment − electromagnetic field originating from radiocommunication and anti-theft systems: - handheld and cordless radiotelephones, short range wireless terminals and devices, body-worn and vehicle-mounted radio stations (radiotelephones) - radar systems: stationary / non-stationary field - equipment emitting an electromagnetic field for purposes other than communication or location | 磁场强度: w zakresie częstotliwości od 5 Hz do 600 kHz w zakresie częstotliwości od 0,8 GHz do 90 GHz (计算得出) |
PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego IMB edycja 4 z dnia 05.06.2025 r. | ||
| 9 | Workplace environment − electromagnetic field from equipment used in medical technology: - surgical diathermy units - physiotherapy diathermy units | 电场强度: w zakresie częstotliwości od 0,1 MHz do 6 GHz 范围 (0,8 – 1000) V/m |
直接测量法 | PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego IMB edycja 4 z dnia 05.06.2025 r. | |
| 10 | Workplace environment − electromagnetic field from equipment used in medical technology: - surgical diathermy units - physiotherapy diathermy units | 磁场强度: w zakresie częstotliwości od 0,1 MHz do 30 MHz 范围 (0,01 – 16) A/m w zakresie częstotliwości od 30 MHz do 1000 MHz 范围 (0,01 – 10) A/m |
直接测量法 | PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego IMB edycja 4 z dnia 05.06.2025 r. | |
| 11 | Workplace environment − electromagnetic field from equipment used in medical technology: - surgical diathermy units - physiotherapy diathermy units | 磁感应强度: w zakresie częstotliwości od 5 Hz do 600 kHz 范围 (30 nT – 20 mT) |
直接测量法 | PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego IMB edycja 4 z dnia 05.06.2025 r. | |
| 12 | Workplace environment − electromagnetic field from equipment used in medical technology: - surgical diathermy units - physiotherapy diathermy units | 磁场强度: w zakresie częstotliwości od 5 Hz do 600 kHz w zakresie częstotliwości od 0,8 GHz do 6 GHz (计算得出) |
PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego IMB edycja 4 z dnia 05.06.2025 r. | ||
| 13 | Workplace environment − electromagnetic field in the workspace during the use of magnetotherapy or magnetostimulation devices | 电场强度: w zakresie częstotliwości od 5 Hz do 100 kHz 范围 1 V/m – 50 kV/m |
直接测量法 | PiMOŚP nr 4(90) 2016 str. 151-180 | |
| 14 | Workplace environment − electromagnetic field in the workspace during the use of magnetotherapy or magnetostimulation devices | 磁场强度: w zakresie częstotliwości od 5 Hz do 100 kHz (计算得出) |
PiMOŚP nr 4(90) 2016 str. 151-180 | ||
| 15 | Workplace environment − electromagnetic field in the workspace during the use of magnetotherapy or magnetostimulation devices | 磁感应强度: w zakresie częstotliwości od 5 Hz do 500 Hz 范围 1 μT – 20 mT w zakresie częstotliwości od 500 Hz do 100 kHz) 范围 (30 nT – 20 mT) |
直接测量法 | PiMOŚP nr 4(90) 2016 str. 151-180 | |
| 16 | Workplace environment − electromagnetic field in the workspace during the use of power systems and alternating current electrical supply installations in the power industry | 电场强度: w zakresie częstotliwości od 45 Hz do 55 Hz 范围 (0,1 – 50) kV/m |
直接测量法 | PiMOŚP nr 4(90) 2016 str. 91-150 | |
| 17 | Workplace environment − electromagnetic field in the workspace during the use of power systems and alternating current electrical supply installations in the power industry | 磁场强度: w zakresie częstotliwości od 45 Hz do 55 Hz (计算得出) |
PiMOŚP nr 4(90) 2016 str. 91-150 | ||
| 18 | Workplace environment − electromagnetic field in the workspace during the use of power systems and alternating current electrical supply installations in the power industry | 磁感应强度: w zakresie częstotliwości od 45 Hz do 55 Hz 范围 1 μT – 20 mT |
直接测量法 | PiMOŚP nr 4(90) 2016 str. 91-150 | |
| 19 | Workplace environment − electromagnetic field in the workspace during the use of transmitting devices of radiocommunication systems | 电场强度: w zakresie częstotliwości od 0,1 MHz do 300 MHz 范围 (0,8 – 1000) V/m w zakresie częstotliwości od 0,3 GHz do 6 GHz 范围 (0,8 – 1000) V/m w zakresie częstotliwości od 6 GHz do 90 GHz 范围 (0,8 – 280) V/m |
直接测量法 | PiMOŚP nr 2(92) 2017 str. 89-131 | |
| 20 | Workplace environment − electromagnetic field in the workspace during the use of transmitting devices of radiocommunication systems | 磁场强度: w zakresie częstotliwości od 0,3 MHz do 30 MHz 范围 (0,01 – 16) A/m w zakresie częstotliwości od 30 MHz do 1000 MHz 范围 (0,01 – 10) A/m |
直接测量法 | PiMOŚP nr 2(92) 2017 str. 89-131 | |
| 21 | Workplace environment − electromagnetic field in the workspace during the use of transmitting devices of radiocommunication systems | 磁场强度: w zakresie częstotliwości od 0,8 GHz do 90 GHz (计算得出) |
PiMOŚP nr 2(92) 2017 str. 89-131 | ||
| 22 | 环境 — 变电站与输电线路周围的电磁场 | 电场强度: 频率范围 50 Hz 范围 (0,1 – 50) kV/m |
直接测量法 | Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630) | |
| 23 | 环境 — 变电站与输电线路周围的电磁场 | 磁感应强度: 频率范围 50 Hz 范围 (1 μT – 20 mT) |
直接测量法 | Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630) | |
| 24 | 环境 — 变电站与输电线路周围的电磁场 | 磁场强度: in the frequency range 50 Hz (calculated) |
Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630) | ||
| 25 | Environment – electromagnetic field in the vicinity of radiocommunication and radionavigation installations (broadband measurements) | 电场强度: w zakresie częstotliwości od 0,1 MHz do 300 MHz 范围 (0,8 – 1000) V/m w zakresie częstotliwości od 0,3 GHz do 6 GHz 范围 (0,8 – 1000) V/m w zakresie częstotliwości od 6 GHz do 90 GHz 范围 (0,8 – 280) V/m |
直接测量法 | Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630) | |
| 26 | Environment – electromagnetic field in the vicinity of radiocommunication and radionavigation installations (broadband measurements) | 磁场强度: 频率范围自 100 kHz 起 do 30 MHz 范围 (0,01 – 16) A/m w zakresie częstotliwości od 30 MHz do 1 GHz 范围 (0,01 – 10) A/m |
直接测量法 | Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630) | |
| 27 | Environment – electromagnetic field in the vicinity of radiocommunication and radionavigation installations (broadband measurements) | 磁场强度: w zakresie częstotliwości: od 10 MHz do 90 GHz (计算得出) |
Punkt. 3 załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630) | ||
| 28 | Environment – electromagnetic field in the vicinity of radiocommunication and radionavigation installations (broadband measurements) | 磁感应强度: w zakresie częstotliwości od 5 Hz do 600 kHz 范围 (30 nT – 20 mT) |
直接测量法 | Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630) | |
| 29 | Environment – electromagnetic field in the vicinity of radiocommunication and radionavigation installations (broadband measurements) | 磁场强度: w zakresie częstotliwości od 5 Hz do 600 kHz (计算得出) |
Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630) | ||
| 30 | Environment – electromagnetic field in the vicinity of radar installations (broadband measurements) | 电场强度: w zakresie częstotliwości od 0,1 MHz do 90 GHz 范围 (0,8 – 300) V/m |
直接测量法 | Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630) | |
| 31 | Environment – electromagnetic field in the vicinity of radar installations (broadband measurements) | 磁场强度: w zakresie częstotliwości od 10 MHz do 90 GHz (计算得出) |
Punkt. 3 załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630) | ||
引用标准 (6)
PN-T-06580-3:2002 Metoda dostosowana do obszaru regulowanego IMB edycja 4 z dnia 05.06.2025 r.
PiMOŚP nr 2(92) 2017 str. 89-131
PiMOŚP nr 4(90) 2016 str. 151-180
PiMOŚP nr 4(90) 2016 str. 91-150
Punkt. 3 załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)
Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)