🇵🇱 POLITECHNIKA RZESZOWSKA im. Ignacego Łukasiewicza PL
电子与电磁兼容
POLITECHNIKA RZESZOWSKA im. Ignacego Łukasiewicza 是由 PCA 认可的实验室,认可编号 AB 1925(Rzeszów,波兰)。认可范围涵盖 13 项检测方法,涉及以下领域:电子与电磁兼容。检测对象包括:Industrial, scientific and medical equipment、Household appliances, electric tools and similar apparatus、Information technology and multimedia equipment、Lighting technology equipment。
要点速览
- 认可编号: PCA AB 1925
- 认可范围内方法数: 13
- 检测对象种类: 5
- 城市: Rzeszów, 波兰
- 认可编号
- AB 1925
- 认可机构
- PCA
- 地址
- Al. Powstańców Warszawy 12, 35-959 Rzeszów, WYDZIAŁ ELEKTROTECHNIKI I INFORMATYKI, Laboratorium Kompatybilności Elektromagnetycznej
- 城市
- Rzeszów, 波兰
该实验室检测什么 (5)
- Industrial, scientific and medical equipment — 4 项方法
- Household appliances, electric tools and similar apparatus — 3 项方法
- Information technology and multimedia equipment — 2 项方法
- Lighting technology equipment — 2 项方法
- 电气与电子设备 — 2 项方法
实验室地点
- Laboratorium Kompatybilności Elektromagnetycznej EMC — ul. Wincentego Pola 2
- Laboratorium Kompatybilności Elektromagnetycznej EMC im Prof. Włodzimierza Kality — ul. Wincentego Pola 2, 35-021 Rzeszów
认可范围 — 项检测方法 (13)
| 序号 | 检测对象 | 方法 / 参数 | 技术 | 依据文件 | |
|---|---|---|---|---|---|
| Prof. Włodzimierz Kalita Electromagnetic Compatibility EMC Laboratory | |||||
| 1 | 电气与电子设备 | Conducted disturbance emission Continuous disturbance voltage 范围 9 kHz – 30 MHz |
PN-EN 55016-2-1:2014-09 | PN-EN 55016-2-1:2014-09/A1:2017-12 | ||
| 2 | Industrial, scientific and medical equipment | Conducted disturbance emission Continuous disturbance voltage 范围 9 kHz – 30 MHz |
PN-EN 55011:2016-05 | PN-EN 55011:2016-05/A1:2017-06 | PN-EN 55011:2016-05/A2:2021-08 | ||
| 3 | Household appliances, electric tools and similar apparatus | Conducted disturbance emission Continuous disturbance voltage 范围 9 kHz – 30 MHz |
PN-EN IEC 55014-1:2021-08 | ||
| 4 | Information technology and multimedia equipment | Conducted disturbance emission Continuous disturbance voltage 范围 9 kHz – 30 MHz |
PN-EN 55032:2015-09 | PN-EN 55032:2015-09/A1:2021-05 | ||
| 5 | Lighting technology equipment | Conducted disturbance emission Continuous disturbance voltage 范围 9 kHz – 30 MHz |
PN-EN IEC 55015:2019-11 | ||
| 6 | 电气与电子设备 | Radiated disturbance emission Electromagnetic field strength Measurement in a SAC chamber 范围 30 MHz – 6 GHz |
PN-EN 55016-2-3:2017-06 | PN-EN 55016-2-3:2017-06/A1:2020-01 | ||
| 7 | Industrial, scientific and medical equipment | Radiated disturbance emission Electromagnetic field strength Measurement in a SAC chamber 范围 30 MHz – 6 GHz |
PN-EN 55011:2016-05 | PN-EN 55011:2016-05/A1:2017-06 | PN-EN 55011:2016-05/A2:2021-08 | ||
| 8 | Household appliances, electric tools and similar apparatus | Radiated disturbance emission Electromagnetic field strength Measurement in a SAC chamber 范围 30 MHz – 6 GHz |
PN-EN IEC 55014-1:2021-08 | ||
| 9 | Information technology and multimedia equipment | Radiated disturbance emission Electromagnetic field strength Measurement in a SAC chamber 范围 30 MHz – 6 GHz |
PN-EN 55032:2015-09 | PN-EN 55032:2015-09/A1:2021-05 | ||
| 10 | Lighting technology equipment | Radiated disturbance emission Electromagnetic field strength Measurement in a SAC chamber 范围 30 MHz – 6 GHz |
PN-EN IEC 55015:2019-11 | ||
| 11 | Household appliances, electric tools and similar apparatus | Disturbance power 范围 30 MHz – 300 MHz |
PN-EN 55016-2-2:2011 | PN-EN IEC 55014-1:2021-08 | ||
| 12 | Industrial, scientific and medical equipment | Conducted emitted disturbances, Current harmonics | PN-EN IEC 61000-3-2:2019-04 | PN-EN IEC 61000-3-2:2019-04/A1:2021-08 | PN-EN 61000-3-12:2012 | PN-EN 61000-4-7:2007 | PN-EN 61000-4-7:2007/A1:2011 | ||
| 13 | Industrial, scientific and medical equipment | Conducted emitted disturbances, Voltage fluctuations and flicker (flickers) | PN-EN 61000-3-3:2013-10 | PN-EN 61000-3-3:2013-10/A1:2019-10 | PN-EN IEC 61000-3-11:2020-01 | PN-EN 61000-4-15:2011 | ||
引用标准 (21)
PN-EN 55011:2016-05
PN-EN 55011:2016-05/A1:2017-06
PN-EN 55011:2016-05/A2:2021-08
PN-EN 55016-2-1:2014-09
PN-EN 55016-2-1:2014-09/A1:2017-12
PN-EN 55016-2-2:2011
PN-EN 55016-2-3:2017-06
PN-EN 55016-2-3:2017-06/A1:2020-01
PN-EN 55032:2015-09
PN-EN 55032:2015-09/A1:2021-05
PN-EN 61000-3-12:2012
PN-EN 61000-3-3:2013-10
PN-EN 61000-3-3:2013-10/A1:2019-10
PN-EN 61000-4-15:2011
PN-EN 61000-4-7:2007
PN-EN 61000-4-7:2007/A1:2011
PN-EN IEC 55014-1:2021-08
PN-EN IEC 55015:2019-11
PN-EN IEC 61000-3-11:2020-01
PN-EN IEC 61000-3-2:2019-04
PN-EN IEC 61000-3-2:2019-04/A1:2021-08