🇵🇱 SIEMENS HEALTHCARE Sp. z o.o. PL
其他
SIEMENS HEALTHCARE Sp. z o.o. 是由 PCA 认可的实验室,认可编号 AB 1843(Warszawa,波兰)。认可范围涵盖 12 项检测方法,涉及以下领域:其他。检测对象包括:Equipment used in computed tomography、Equipment used in fluoroscopy and angiography、Equipment used in general digital radiography、Planar scintillation cameras。
要点速览
- 认可编号: PCA AB 1843
- 认可范围内方法数: 12
- 检测对象种类: 6
- 城市: Warszawa, 波兰
- 认可编号
- AB 1843
- 认可机构
- PCA
- 地址
- ul. Polna 11, 00-633 Warszawa, LABORATORIUM BADAWCZE, ul. Gdańska 4a
- 城市
- Warszawa, 波兰
该实验室检测什么 (6)
- Equipment used in computed tomography — 2 项方法
- Equipment used in fluoroscopy and angiography — 2 项方法
- Equipment used in general digital radiography — 2 项方法
- Planar scintillation cameras — 2 项方法
- SPECT and SPECT/CT cameras — 2 项方法
- 医学影像显示用监视器 — 2 项方法
认可范围 — 项检测方法 (12)
| 序号 | 检测对象 | 方法 / 参数 | 技术 | 依据文件 | |
|---|---|---|---|---|---|
| 检测方法 | |||||
| 1 | Equipment used in computed tomography | Acceptance tests covering measurements of: HU value image uniformity tube output volume computed tomography dose index (CTDIvol) layer thickness accuracy of high voltage setting repeatability of the high voltage value high voltage value with changing current |
PB-CT wyd. 1 z 06.05.2024 r. | ||
| 2 | 医学影像显示用监视器 | Acceptance tests covering measurements of: uniformity luminance – consistency of maximum luminance between monitors luminance – monitor contrast luminance - greyscale curve |
PB-MON wyd. 1 z 06.05.2024 r. | ||
| 3 | Planar scintillation cameras | Acceptance tests covering measurements of: pixel size system sensitivity |
PB-MN wyd. 1 z 06.05.2024 r. | ||
| 4 | SPECT and SPECT/CT cameras | Acceptance tests covering measurements of: pixel size system sensitivity tomographic spatial resolution in air tomographic uniformity of the system |
PB-MN wyd. 1 z 06.05.2024 r. | ||
| 5 | Equipment used in general digital radiography | Acceptance tests covering measurements of: accuracy of high voltage setting repeatability of the high voltage value high voltage value with changing current − exposure time − half-value layer (HVL) − X-ray tube output − repeatability of X-ray tube output − X-ray tube output value with changing current − X-ray tube output value with changing current-time product − focal spot size − perpendicularity of the X-ray beam axis − coincidence of the centre of the X-ray field with the centre of the resulting image − coincidence of the centre of the X-ray field with the centre of the light field cross − coincidence of the centre of the light field cross with the centre of the resulting image − coincidence of the X-ray radiation field with the field of the resulting image for collimators with automatic field setting − coincidence of the X-ray radiation field with the light field for collimators with manual field setting − illuminance of the light field simulating the X-ray radiation field − assessment of the repeatability of the AEC system − assessment of the AEC system with changing phantom thickness sensitivity of imaging plates (CR systems) |
PB-RO wyd.2 z 25.06.2024 r. | ||
| 6 | Equipment used in fluoroscopy and angiography | Acceptance tests covering measurements of: − accuracy of the high voltage setting − repeatability of the high voltage value − high voltage value with varying tube current − exposure time − half-value layer (HVL) − X-ray tube output − repeatability of the X-ray tube output − X-ray tube output with varying tube current − X-ray tube output with varying current-time product − perpendicularity of the X-ray beam axis − congruence of the centre of the X-ray field with the centre of the resulting image coincidence of the centre of the X-ray field with the centre of the light field cross − coincidence of the centre of the light field cross with the centre of the resulting image − coincidence of the X-ray radiation field with the field of the resulting image for collimators with automatic field setting − coincidence of the X-ray radiation field with the light field for collimators with manual field setting − illuminance of the light field simulating the X-ray radiation field − assessment of the repeatability of the AEC system − assessment of the AEC system with changing phantom thickness − dose rate at the input of the image intensifier/ image receptor/ digital detector − dose rate at the entrance surface of the phantom − high-contrast resolution of the imaging chain − threshold image contrast − coincidence of the X-ray radiation field with the field of view of the image receptor − entrance dose per image at the input of the image intensifier/ image receptor/ digital detector − entrance dose per image at the entrance surface of the phantom |
PB-F wyd. 1 z 06.05.2024 | ||
| 7 | Equipment used in computed tomography | 专项检测 | Załącznik nr 1 do rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz.U. 2022 poz. 2759) | PB-CT wyd. 1 z 06.05.2024 r. | ||
| 8 | 医学影像显示用监视器 | 专项检测 | Załącznik nr 2 do rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz.U. 2022 poz. 2759) | PB-MON wyd.1 z 06.05.2024 | ||
| 9 | Planar scintillation cameras | 专项检测 | Załącznik nr 1 do rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz.U. 2022 poz. 2759) | PB-MN wyd.1 z 06.05.2024 | ||
| 10 | SPECT and SPECT/CT cameras | 专项检测 | Załącznik nr 1 do rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz.U. 2022 poz. 2759) | PB-MN wyd. 1 z 06.05.2024 | ||
| 11 | Equipment used in general digital radiography | 专项检测 | Załącznik nr 1 i 2 do rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz.U. 2022 poz. 2759) | PB-RO wyd. 2 z 25.06.2024 r. | ||
| 12 | Equipment used in fluoroscopy and angiography | 专项检测 | Załącznik nr 1 do rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz.U. 2022 poz. 2759) | PB-F wyd. 1 z 06.05.2024 r. | ||
引用标准 (13)
PB-CT wyd. 1 z 06.05.2024 r.
PB-F wyd. 1 z 06.05.2024
PB-F wyd. 1 z 06.05.2024 r.
PB-MN wyd. 1 z 06.05.2024
PB-MN wyd. 1 z 06.05.2024 r.
PB-MN wyd.1 z 06.05.2024
PB-MON wyd. 1 z 06.05.2024 r.
PB-MON wyd.1 z 06.05.2024
PB-RO wyd. 2 z 25.06.2024 r.
PB-RO wyd.2 z 25.06.2024 r.
Załącznik nr 1 do rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz.U. 2022 poz. 2759)
Załącznik nr 1 i 2 do rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz.U. 2022 poz. 2759)
Załącznik nr 2 do rozporządzenia Ministra Zdrowia z dnia 12 grudnia 2022 r. (Dz.U. 2022 poz. 2759)