STREFA MICHAŁ GRĄCKI 是由 PCA 认可的实验室,认可编号 AB 1709(Zajezierze,波兰)。认可范围涵盖 22 项检测方法,涉及以下领域:环境、电子与电磁兼容。检测对象包括:Workplace environment − electromagnetic field originating from equi…、Workplace environment − electromagnetic field originating from indu…、Workplace environment - electromagnetic field from transmitting dev…、Workplace environment - electromagnetic field from transmitting dev…。最常用的技术:直接测量法、Direct measurement method (simplified)。
要点速览
- 认可编号: PCA AB 1709
- 认可范围内方法数: 22
- 检测对象种类: 8
- 所用技术数: 2
- 城市: Zajezierze, 波兰
- 认可编号
- AB 1709
- 认可机构
- PCA
- 地址
- Zajezierze 8E, 88-140 Zajezierze
- 城市
- Zajezierze, 波兰
该实验室检测什么 (8)
- Workplace environment − electromagnetic field originating from equipment used in medical technology: - physiotherapeutic diathermy - magnetic resonance scanners — 4 项方法
- Workplace environment − electromagnetic field originating from industrial installations and equipment: - NMR spectrometers - dielectric heating equipment - special equipment: radio frequency defrosting device — 4 项方法
- Workplace environment - electromagnetic field from transmitting devices of radiocommunication systems (base stations of mobile telephony systems) — 3 项方法
- Workplace environment - electromagnetic field from transmitting devices of radiocommunication systems (broadcasting tele- and radiocommunication systems - radio, television, etc.) — 3 项方法
- Workplace environment − electromagnetic field from radiocommunication and anti-theft systems: - hand-held and cordless radiotelephones, short-range wireless terminals and devices, body-worn and vehicle-mounted radio stations (radiotelephones) - anti-theft and electronic article surveillance systems — 3 项方法
- Environment – electromagnetic field in the vicinity of radiocommunication installations (selective measurements) — 2 项方法
- 环境 – 无线电通信设施周围的电磁场(宽带测量) — 2 项方法
- 工作场所环境 — 工作空间内来自磁疗设备的电磁场 — 1 项方法
所用检测技术 (2)
- 直接测量法 — 14 项方法
- Direct measurement method (simplified) — 1 项方法
认可范围 — 项检测方法 (22)
| 序号 | 检测对象 | 方法 / 参数 | 技术 | 依据文件 | |
|---|---|---|---|---|---|
| 检测方法 | |||||
| 1 | 环境 – 无线电通信设施周围的电磁场(宽带测量) | 电场强度: w zakresie częstotliwości od 80 MHz do 90 GHz 范围 (0,5 – 300) V/m |
直接测量法 | Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630) | |
| 2 | 环境 – 无线电通信设施周围的电磁场(宽带测量) | 磁场强度: w zakresie częstotliwości od 80 MHz do 90 GHz (计算得出) |
Punkt 3 załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630) | ||
| 3 | Environment – electromagnetic field in the vicinity of radiocommunication installations (selective measurements) | 电场强度: w zakresie częstotliwości od 27 MHz do 4 GHz 范围 0,2 V/m – 255 V/m |
直接测量法 | Załącznik do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630) | |
| 4 | Environment – electromagnetic field in the vicinity of radiocommunication installations (selective measurements) | 磁场强度: w zakresie częstotliwości od 27 MHz do 4 GHz (计算得出) |
Punkt 3 załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630) | ||
| 5 | 工作场所环境 — 工作空间内来自磁疗设备的电磁场 | 磁感应强度: w zakresie częstotliwości od 30 Hz do 50 Hz 范围 0,5 μT – 1,9 mT |
Direct measurement method (simplified) | Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151 - 180 | |
| 6 | Workplace environment - electromagnetic field from transmitting devices of radiocommunication systems (base stations of mobile telephony systems) | 电场强度: w zakresie częstotliwości od 420 MHz do 90 GHz 范围 (0,5 – 300) V/m |
直接测量法 | Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 - 131 | |
| 7 | Workplace environment - electromagnetic field from transmitting devices of radiocommunication systems (base stations of mobile telephony systems) | 磁场强度: w zakresie częstotliwości od 420 MHz do 800 MHz 范围 (0,01 – 2) A/m |
直接测量法 | Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 - 131 | |
| 8 | Workplace environment - electromagnetic field from transmitting devices of radiocommunication systems (base stations of mobile telephony systems) | 磁场强度: w zakresie częstotliwości od 800 MHz do 90 GHz (计算得出) |
Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 - 131 | ||
| 9 | Workplace environment - electromagnetic field from transmitting devices of radiocommunication systems (broadcasting tele- and radiocommunication systems - radio, television, etc.) | 电场强度: w zakresie częstotliwości od 85 MHz do 90 GHz 范围 (0,5 – 300) V/m |
直接测量法 | Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 - 131 | |
| 10 | Workplace environment - electromagnetic field from transmitting devices of radiocommunication systems (broadcasting tele- and radiocommunication systems - radio, television, etc.) | 磁场强度: w zakresie częstotliwości od 85 MHz do 1 GHz 范围 (0,01 – 2) A/m |
直接测量法 | Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 - 131 | |
| 11 | Workplace environment - electromagnetic field from transmitting devices of radiocommunication systems (broadcasting tele- and radiocommunication systems - radio, television, etc.) | 磁场强度: w zakresie częstotliwości od 800 MHz do 90 GHz (计算得出) |
Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 - 131 | ||
| 12 | Workplace environment − electromagnetic field originating from industrial installations and equipment: - NMR spectrometers - dielectric heating equipment - special equipment: radio frequency defrosting device | 磁感应强度: w zakresie częstotliwości 0 Hz 范围 100 μT − 1000 mT |
直接测量法 | PN-T-06580-3:2002 | PB-01 Procedura Badawcza wyd. 1 z 24.09.2018 r. | PB-02 Procedura Badawcza wyd. 3 z 04.01.2022 r. | |
| 13 | Workplace environment − electromagnetic field originating from industrial installations and equipment: - NMR spectrometers - dielectric heating equipment - special equipment: radio frequency defrosting device | 电场强度: w zakresie częstotliwości od 27 MHz do 3 GHz 范围 (0,5 − 300) V/m |
直接测量法 | PN-T-06580-3:2002 | PB-01 Procedura Badawcza wyd. 1 z 24.09.2018 r. | PB-02 Procedura Badawcza wyd. 3 z 04.01.2022 r. | |
| 14 | Workplace environment − electromagnetic field originating from industrial installations and equipment: - NMR spectrometers - dielectric heating equipment - special equipment: radio frequency defrosting device | 磁场强度: w zakresie częstotliwości od 27 MHz do 1 GHz 范围 (0,01 – 2) A/m |
直接测量法 | PN-T-06580-3:2002 | PB-01 Procedura Badawcza wyd. 1 z 24.09.2018 r. | PB-02 Procedura Badawcza wyd. 3 z 04.01.2022 r. | |
| 15 | Workplace environment − electromagnetic field originating from industrial installations and equipment: - NMR spectrometers - dielectric heating equipment - special equipment: radio frequency defrosting device | 磁场强度: w zakresie częstotliwości od 1 GHz do 3 GHz (计算得出) |
PN-T-06580-3:2002 | PB-01 Procedura Badawcza wyd. 1 z 24.09.2018 r. | PB-02 Procedura Badawcza wyd. 3 z 04.01.2022 r. | ||
| 16 | Workplace environment − electromagnetic field from radiocommunication and anti-theft systems: - hand-held and cordless radiotelephones, short-range wireless terminals and devices, body-worn and vehicle-mounted radio stations (radiotelephones) - anti-theft and electronic article surveillance systems | 电场强度: w zakresie częstotliwości od 27 MHz do 3 GHz 范围 (0,5 − 300) V/m |
直接测量法 | PN-T-06580-3:2002 | PB-01 Procedura Badawcza wyd. 1 z 24.09.2018 r. | PB-02 Procedura Badawcza wyd. 3 z 04.01.2022 r. | |
| 17 | Workplace environment − electromagnetic field from radiocommunication and anti-theft systems: - hand-held and cordless radiotelephones, short-range wireless terminals and devices, body-worn and vehicle-mounted radio stations (radiotelephones) - anti-theft and electronic article surveillance systems | 磁场强度: w zakresie częstotliwości od 27 MHz do 1 GHz 范围 (0,01 – 2) A/m |
直接测量法 | PN-T-06580-3:2002 | PB-01 Procedura Badawcza wyd. 1 z 24.09.2018 r. | PB-02 Procedura Badawcza wyd. 3 z 04.01.2022 r. | |
| 18 | Workplace environment − electromagnetic field from radiocommunication and anti-theft systems: - hand-held and cordless radiotelephones, short-range wireless terminals and devices, body-worn and vehicle-mounted radio stations (radiotelephones) - anti-theft and electronic article surveillance systems | 磁场强度: w zakresie częstotliwości od 1 GHz do 3 GHz (计算得出) |
PN-T-06580-3:2002 | PB-01 Procedura Badawcza wyd. 1 z 24.09.2018 r. | PB-02 Procedura Badawcza wyd. 3 z 04.01.2022 r. | ||
| 19 | Workplace environment − electromagnetic field originating from equipment used in medical technology: - physiotherapeutic diathermy - magnetic resonance scanners | 磁感应强度: w zakresie częstotliwości 0 Hz 范围 100 μT − 1000 mT |
直接测量法 | PN-T-06580-3:2002 | PB-01 Procedura Badawcza wyd. 1 z 24.09.2018 r. | PB-02 Procedura Badawcza wyd. 3 z 04.01.2022 r. | |
| 20 | Workplace environment − electromagnetic field originating from equipment used in medical technology: - physiotherapeutic diathermy - magnetic resonance scanners | 电场强度: w zakresie częstotliwości od 27 MHz do 3 GHz 范围 (0,5 − 300) V/m |
直接测量法 | PN-T-06580-3:2002 | PB-01 Procedura Badawcza wyd. 1 z 24.09.2018 r. | PB-02 Procedura Badawcza wyd. 3 z 04.01.2022 r. | |
| 21 | Workplace environment − electromagnetic field originating from equipment used in medical technology: - physiotherapeutic diathermy - magnetic resonance scanners | 磁场强度: w zakresie częstotliwości od 27 MHz do 1 GHz 范围 (0,01 – 2) A/m |
直接测量法 | PN-T-06580-3:2002 | PB-01 Procedura Badawcza wyd. 1 z 24.09.2018 r. | PB-02 Procedura Badawcza wyd. 3 z 04.01.2022 r. | |
| 22 | Workplace environment − electromagnetic field originating from equipment used in medical technology: - physiotherapeutic diathermy - magnetic resonance scanners | 磁场强度: w zakresie częstotliwości od 1 GHz do 3 GHz (计算得出) |
PN-T-06580-3:2002 | PB-01 Procedura Badawcza wyd. 1 z 24.09.2018 r. | PB-02 Procedura Badawcza wyd. 3 z 04.01.2022 r. | ||
引用标准 (7)
PB-01 Procedura Badawcza wyd. 1 z 24.09.2018 r.
PB-02 Procedura Badawcza wyd. 3 z 04.01.2022 r.
PN-T-06580-3:2002
Podstawy i Metody Oceny Środowiska Pracy 2016, nr 4 (90), s. 151 - 180
Podstawy i Metody Oceny Środowiska Pracy 2017, nr 2 (92), s. 89 - 131
Punkt 3 załącznika do Rozporządzenia Ministra Klimatu z dnia 17.02.2020 r. (Dz.U. 2022 poz. 2630)