🇵🇱 ChM sp. z o.o. PL
材料与高分子水与废水微生物
ChM sp. z o.o. 是由 PCA 认可的实验室,认可编号 AB 1629(Juchnowiec Kościelny,波兰)。认可范围涵盖 8 项检测方法,涉及以下领域:材料与高分子、水与废水、微生物。检测对象包括:Metals, metal alloys, metal products, Meto、Medical devices (implants and instruments)、水。最常用的技术:Comparative method according to the scale of standards; Intercept m…、Culture method: direct immersion, membrane filtration、Method: Static 4-point bending test。
要点速览
- 认可编号: PCA AB 1629
- 认可范围内方法数: 8
- 检测对象种类: 3
- 所用技术数: 8
- 城市: Juchnowiec Kościelny, 波兰
- 认可编号
- AB 1629
- 认可机构
- PCA
- 地址
- Lewickie 3B, 16-061 Juchnowiec Kościelny
- 城市
- Juchnowiec Kościelny, 波兰
该实验室检测什么 (3)
- Metals, metal alloys, metal products, Meto — 4 项方法
- Medical devices (implants and instruments) — 2 项方法
- 水 — 2 项方法
所用检测技术 (8)
- Comparative method according to the scale of standards; Intercept method; Planimetric method — 1 项方法
- Culture method: direct immersion, membrane filtration — 1 项方法
- Method: Static 4-point bending test — 1 项方法
- Method: static compressive bending test — 1 项方法
- Method: Tensile test at room temperature — 1 项方法
- 电感耦合等离子体原子发射光谱法(ICP-OES) — 1 项方法
- 红外光谱法(IR) — 1 项方法
- 膜过滤法 — 1 项方法
实验室部门 (3)
- Biomechanical Laboratory; Lewickie 3B, 16-061 Juchnowiec Kościelny — 4 项方法
- Microbiology Laboratory; Lewickie 3B, 16-061 Juchnowiec Kościelny — 2 项方法
- Physicochemical Laboratory; Lewickie 3B, 16-061 Juchnowiec Kościelny — 2 项方法
实验室地点
- Laboratorium Biomechaniczne — Lewickie 3B, 16-061 Juchnowiec Kościelny
- Laboratorium Mikrobiologiczne — Lewickie 3B, 16-061 Juchnowiec Kościelny
- Laboratorium Fizykochemiczne — Lewickie 3B, 16-061 Juchnowiec Kościelny
- Laboratorium Biomechaniczne; Lewickie 3B, 16-061 Juchnowiec Kościelny —
- Laboratorium Fizykochemiczne; Lewickie 3B, 16-061 Juchnowiec Kościelny —
- Laboratorium Mikrobiologiczne; Lewickie 3B, 16-061 Juchnowiec Kościelny —
认可范围 — 项检测方法 (8)
| 序号 | 检测对象 | 方法 / 参数 | 技术 | 依据文件 | |
|---|---|---|---|---|---|
| Biomechanical Laboratory; Lewickie 3B, 16-061 Juchnowiec Kościelny | |||||
| 1 | Metals, metal alloys, metal products, Meto | Mechanical properties: umowna granica plastyczności Rp wyraźna granica plastyczności Re 抗拉强度 Rm wydłużenie ekstensometryczne Ag, At, Agt, wydłużenie A przewężenie Z 力 do 100 kN |
Method: Tensile test at room temperature | PN-EN ISO 6892-1:2020-05 metoda B | |
| 2 | Metals, metal alloys, metal products, Meto | Mechanical properties: wytrzymałość na zginanie sztywność zginania K strukturalna sztywność zginania Ele 力 do 100 kN |
Method: Static 4-point bending test | ASTM F382-24 Annex A1 | |
| 3 | Metals, metal alloys, metal products, Meto | Grain size Optical microscopy |
Comparative method according to the scale of standards; Intercept method; Planimetric method | ASTM E112-25 | PN-EN ISO 643:2025-02 | |
| 4 | Metals, metal alloys, metal products, Meto | Mechanical strengths: maximum load, displacement at maximum load, load at 2% deformation, displacement in the elastic range, bending stiffness |
Method: static compressive bending test | ASTM F1717-21 | |
| Microbiology Laboratory; Lewickie 3B, 16-061 Juchnowiec Kościelny | |||||
| 5 | Medical devices (implants and instruments) | Microorganism count, Aerobic bacteria count, Fungal count (yeasts and moulds) | 膜过滤法 | PN-EN ISO 11737-1:2018-03 | |
| 6 | Medical devices (implants and instruments) | Sterility | Culture method: direct immersion, membrane filtration | PN-EN ISO 11737-2:2020-11 | |
| Physicochemical Laboratory; Lewickie 3B, 16-061 Juchnowiec Kościelny | |||||
| 7 | 水 | Total organic carbon TOC concentration 范围 (0,2 – 10) mg/l |
红外光谱法(IR) | PN-EN 1484:1999 | |
| 8 | 水 | 元素浓度 Mo (5,0 - 1000) μg/l Pb (5,0 - 1000) μg/l Co (3,0 - 1000) μg/l Ni (3,0 - 1000) μg/l Cr (3,0 - 1000) μg/l V (3,0 - 1000) μg/l Cu (3,0 - 1000) μg/l |
电感耦合等离子体原子发射光谱法(ICP-OES) | PN-EN ISO 11885:2009 | |
引用标准 (9)
ASTM E112-25
ASTM F1717-21
ASTM F382-24 Annex A1
PN-EN 1484:1999
PN-EN ISO 11737-1:2018-03
PN-EN ISO 11737-2:2020-11
PN-EN ISO 11885:2009
PN-EN ISO 643:2025-02
PN-EN ISO 6892-1:2020-05 metoda B