ZAKŁAD OCHRONY ŚRODOWISKA „DECYBEL” S.C. 是由 PCA 认可的实验室,认可编号 AB 1240(Jelenia Góra,波兰)。认可范围涵盖 9 项检测方法,涉及以下领域:环境。检测对象包括:一般环境 — 来自装置、设备和工业企业的噪声、General environment - noise barriers „in situ”、General environment - noise from roads and railway lines, tram lines、Machinery and equipment - noise。
要点速览
- 认可编号: PCA AB 1240
- 认可范围内方法数: 9
- 检测对象种类: 4
- 城市: Jelenia Góra, 波兰
- 认可编号
- AB 1240
- 认可机构
- PCA
- 地址
- MARIUSZ SZALEJ, ANETA SZALEJ, LABORATORIUM POMIARÓW AKUSTYCZNYCH, ul. Wolności 150, 58-500 Jelenia Góra
- 城市
- Jelenia Góra, 波兰
该实验室检测什么 (4)
- 一般环境 — 来自装置、设备和工业企业的噪声 — 3 项方法
- General environment - noise barriers „in situ” — 2 项方法
- General environment - noise from roads and railway lines, tram lines — 2 项方法
- Machinery and equipment - noise — 2 项方法
认可范围 — 项检测方法 (9)
| 序号 | 检测对象 | 方法 / 参数 | 技术 | 依据文件 | |
|---|---|---|---|---|---|
| 检测方法 | |||||
| 1 | 一般环境 — 来自装置、设备和工业企业的噪声 | A-weighted equivalent sound level, Range: (25 – 137) dB Direct measurement method | nr 7 | enia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023 poz. 1706) PN-ISO 9613-2:2002 | ||
| 2 | 一般环境 — 来自装置、设备和工业企业的噪声 | A-weighted equivalent sound level over the reference time T expressed by the indicators LAeqD, LAeqN, (calculated) | |||
| 3 | 一般环境 — 来自装置、设备和工业企业的噪声 | A-weighted equivalent sound level (calculation method) | |||
| 4 | General environment - noise from roads and railway lines, tram lines | A-weighted equivalent sound level, A-weighted sound exposure level Range: (25 – 137) dB Direct measurement method | nr 3 | enia Ministra Środowiska z dnia 16.06.2011 r. (Dz. U. Nr 140 | nr 288 | eniem punktu H | ||
| 5 | General environment - noise from roads and railway lines, tram lines | A-weighted equivalent sound level over the reference time T expressed by the indicators LAeqD, LAeqN, (calculated) | |||
| 6 | General environment - noise barriers „in situ” | A-weighted equivalent sound level Range: (25 – 137) dB Direct measurement method. | PN-ISO 10847:2002 | ||
| 7 | General environment - noise barriers „in situ” | Effectiveness of screens (calculated) | |||
| 8 | Machinery and equipment - noise | A-weighted equivalent sound level, A-weighted sound exposure level Range: (25 - 137) dB Direct measurement method | PN-EN ISO 3746:2011 PN-EN ISO 3746:2011/Ap1:2017-09 | ||
| 9 | Machinery and equipment - noise | Sound power level Sound energy level (calculated) | |||
引用标准 (8)
PN-EN ISO 3746:2011 PN-EN ISO 3746:2011/Ap1:2017-09
PN-ISO 10847:2002
enia Ministra Klimatu i Środowiska z dnia 07.09.2021 r. (t.j. Dz.U. 2023 poz. 1706) PN-ISO 9613-2:2002
enia Ministra Środowiska z dnia 16.06.2011 r. (Dz. U. Nr 140
eniem punktu H
nr 288
nr 3