🇵🇱 „ZAKŁAD WODOCIĄGÓW I KANALIZACJI – SOCHACZEW” Sp. z o.o. PL
水与废水微生物
„ZAKŁAD WODOCIĄGÓW I KANALIZACJI – SOCHACZEW” Sp. z o.o. 是由 PCA 认可的实验室,认可编号 AB 1117(Sochaczew,波兰)。认可范围涵盖 34 项检测方法,涉及以下领域:水与废水、微生物。检测对象包括:生活饮用水、污水、Water intended for human consumption Wastewater、Rainwater and snowmelt water。
要点速览
- 认可编号: PCA AB 1117
- 认可范围内方法数: 34
- 检测对象种类: 4
- 城市: Sochaczew, 波兰
- 认可编号
- AB 1117
- 认可机构
- PCA
- 地址
- ul. Rozlazłowska 7, 96-500 Sochaczew, LABORATORIUM WODNO-ŚCIEKOWE, al. 600-lecia 69
- 城市
- Sochaczew, 波兰
该实验室检测什么 (4)
- 生活饮用水 — 19 项方法
- 污水 — 10 项方法
- Water intended for human consumption Wastewater — 3 项方法
- Rainwater and snowmelt water — 2 项方法
认可范围 — 项检测方法 (34)
| 序号 | 检测对象 | 方法 / 参数 | 技术 | 依据文件 | |
|---|---|---|---|---|---|
| 检测方法 | |||||
| 1 | 生活饮用水 | 化学与物理检测用样品采集 | PN-ISO 5667-5:2017-10 | ||
| 2 | 生活饮用水 | Colour Range: (2 – 100) mg/l Pt Spectrophotometric method | PN-EN ISO 7887:2012 metoda C +Ap1:2015-06 | ||
| 3 | 生活饮用水 | Turbidity Range: (0,10 – 20) NTU Nephelometric method | PN-EN ISO 7027-1:2016-09 | ||
| 4 | 生活饮用水 | Electrical conductivity Range: (80 – 13000) µS/cm Conductometric method | PN-EN 27888:1999 | ||
| 5 | 生活饮用水 | Nitrate concentration Range: (0,30 – 50) mg/l Spectrophotometric method | PN-82/C-04576.08 | ||
| 6 | 生活饮用水 | Nitrite concentration Range: (0,030 – 2,0) mg/l Spectrophotometric method | PN-EN 26777:1999 | ||
| 7 | 生活饮用水 | Ammonium ion concentration Range: (0,12 – 1,0) mg/l Spectrophotometric method | PN-ISO 7150-1:2002 | ||
| 8 | 生活饮用水 | Manganese concentration Range: (0,030 – 1,0) mg/l Spectrophotometric method | PB-01 wydanie 6 z dnia 28.02.2019 r. na podstawie testu Merck 114770 | ||
| 9 | 生活饮用水 | Free chlorine concentration Range: (0,08 – 1,00) mg/l Spectrophotometric method | PB-07 wydanie 1 z dnia 28.12.2009 r. na podstawie metodyki z odczynnikiem DPD | ||
| 10 | 生活饮用水 | Permanganate index Range: (0,6 – 10) mg/l O 2 Titrimetric method | PN-EN ISO 8467:2001 | ||
| 11 | 生活饮用水 | Aluminium concentration Range: (0,05 – 0,4) mg/l Spectrophotometric method | PB-16 wydanie 2 z dnia 31.05.2013 r. na podstawie testu Hach Lange LCK 301 | ||
| 12 | 生活饮用水 | Total calcium and magnesium content (total hardness) Range: (18 – 500) mg/l CaCO 3 Titrimetric method | PN-ISO 6059:1999 | ||
| 13 | 生活饮用水 | Total viable count at 22 °C Plate method (pour plate) | PN-EN ISO 6222:2004 | ||
| 14 | 生活饮用水 | Total viable count at 36 °C Plate method (pour plate) | |||
| 15 | 生活饮用水 | Most probable number of intestinal enterococci MPN method | PB-19 wydanie 3 z dnia 27.02.2019 r. na podstawie testu Idexx Enterolert-DW | ||
| 16 | 生活饮用水 | Most probable number of coliform bacteria MPN method | PN-EN ISO 9308-2:2014-06 | ||
| 17 | 生活饮用水 | Most probable number of Escherichia coli MPN method | |||
| 18 | 生活饮用水 | 微生物检测用样品采集 | PN-EN ISO 19458:2007 | ||
| 19 | 生活饮用水 | 肠球菌计数 膜过滤法 | PN-EN ISO 7899-2:2004 | ||
| 20 | Water intended for human consumption Wastewater | pH Range: 2,0 – 11,0 Potentiometric method | PN-EN ISO 10523:2012 | ||
| 21 | Water intended for human consumption Wastewater | Chloride concentration Range: (10,0 – 400) mg/l Titrimetric method | PN-ISO 9297:1994 | ||
| 22 | Water intended for human consumption Wastewater | Iron concentration Range: (0,050 – 5,00) mg/l Spectrophotometric method | PN-ISO 6332:2001 p. 7.1.1 +Ap1:2016-06 | ||
| 23 | Rainwater and snowmelt water | Sampling for chemical and physical testing Manual method | PN-ISO 5667-10:2021-11 | ||
| 24 | Rainwater and snowmelt water | Total suspended solids Range: (2,0 – 200) mg/l Gravimetric method | PN-EN 872:2007+Ap1:2007 | ||
| 25 | 污水 | Sampling for chemical and physical testing Manual method Automatic method Temperature of wastewater/of the wastewater sample taken Range: (1,0 – 40,0) °C | PN-ISO 5667-10:2021-11 PN-77/C-04584 | ||
| 26 | 污水 | Total suspended solids (TSS) Range: (2,0 – 1000) mg/l Gravimetric method | PN-EN 872:2007+Ap1:2007 | ||
| 27 | 污水 | Biochemical oxygen demand - BOD 5 Range: (3 – 3000) mg/l O 2 Electrochemical method | PN-EN ISO 5815-1:2019-12 | ||
| 28 | 污水 | Biochemical oxygen demand - BOD 5 Range: (2,0 – 6,0) mg/l O 2 Electrochemical method | PN-EN 1899-2:2002 | ||
| 29 | 污水 | Chemical oxygen demand - COD-Cr Range: (20,0 – 5000) mg/l O 2 Spectrophotometric method | PN-ISO 15705:2005 | ||
| 30 | 污水 | Total phosphorus concentration Range: (0,20 – 25,0) mg/l Spectrophotometric method | PN-EN ISO 6878:2006 p. 7 +Ap1:2010+Ap2:2010 | ||
| 31 | 污水 | Nitrate nitrogen concentration Range: (0,100 – 20,0) mg/l Spectrophotometric method | PN-82/C-04576.08 | ||
| 32 | 污水 | Nitrite nitrogen concentration Range: (0,0036 – 2,58) mg/l Spectrophotometric method | PN-EN 26777:1999 | ||
| 33 | 污水 | Kjeldahl nitrogen concentration Range: (1,0 – 250) mg/l Titrimetric method | PN-EN 25663:2001 | ||
| 34 | 污水 | Total nitrogen (calculated) | PB-20 wydanie 1 z dnia 01.02.2019 r. | ||
引用标准 (29)
PB-01 wydanie 6 z dnia 28.02.2019 r. na podstawie testu Merck 114770
PB-07 wydanie 1 z dnia 28.12.2009 r. na podstawie metodyki z odczynnikiem DPD
PB-16 wydanie 2 z dnia 31.05.2013 r. na podstawie testu Hach Lange LCK 301
PB-19 wydanie 3 z dnia 27.02.2019 r. na podstawie testu Idexx Enterolert-DW
PB-20 wydanie 1 z dnia 01.02.2019 r.
PN-82/C-04576.08
PN-EN 1899-2:2002
PN-EN 25663:2001
PN-EN 26777:1999
PN-EN 27888:1999
PN-EN 872:2007+Ap1:2007
PN-EN ISO 10523:2012
PN-EN ISO 19458:2007
PN-EN ISO 5815-1:2019-12
PN-EN ISO 6222:2004
PN-EN ISO 6878:2006 p. 7 +Ap1:2010+Ap2:2010
PN-EN ISO 7027-1:2016-09
PN-EN ISO 7887:2012 metoda C +Ap1:2015-06
PN-EN ISO 7899-2:2004
PN-EN ISO 8467:2001
PN-EN ISO 9308-2:2014-06
PN-ISO 15705:2005
PN-ISO 5667-10:2021-11
PN-ISO 5667-10:2021-11 PN-77/C-04584
PN-ISO 5667-5:2017-10
PN-ISO 6059:1999
PN-ISO 6332:2001 p. 7.1.1 +Ap1:2016-06
PN-ISO 7150-1:2002
PN-ISO 9297:1994