🇵🇱 „ZAKŁAD WODOCIĄGÓW I KANALIZACJI – SOCHACZEW” Sp. z o.o. PL

PCA AB 1117 • Sochaczew, 波兰 • 34 项方法

水与废水微生物

„ZAKŁAD WODOCIĄGÓW I KANALIZACJI – SOCHACZEW” Sp. z o.o. 是由 PCA 认可的实验室,认可编号 AB 1117(Sochaczew,波兰)。认可范围涵盖 34 项检测方法,涉及以下领域:水与废水、微生物。检测对象包括:生活饮用水、污水、Water intended for human consumption Wastewater、Rainwater and snowmelt water。

要点速览

  • 认可编号: PCA AB 1117
  • 认可范围内方法数: 34
  • 检测对象种类: 4
  • 城市: Sochaczew, 波兰
认可编号
AB 1117
认可机构
PCA
地址
ul. Rozlazłowska 7, 96-500 Sochaczew, LABORATORIUM WODNO-ŚCIEKOWE, al. 600-lecia 69
城市
Sochaczew, 波兰

该实验室检测什么 (4)

认可范围 — 项检测方法 (34)

序号 检测对象 方法 / 参数 技术 依据文件
检测方法
1 生活饮用水 化学与物理检测用样品采集 PN-ISO 5667-5:2017-10
2 生活饮用水 Colour Range: (2 – 100) mg/l Pt Spectrophotometric method PN-EN ISO 7887:2012 metoda C +Ap1:2015-06
3 生活饮用水 Turbidity Range: (0,10 – 20) NTU Nephelometric method PN-EN ISO 7027-1:2016-09
4 生活饮用水 Electrical conductivity Range: (80 – 13000) µS/cm Conductometric method PN-EN 27888:1999
5 生活饮用水 Nitrate concentration Range: (0,30 – 50) mg/l Spectrophotometric method PN-82/C-04576.08
6 生活饮用水 Nitrite concentration Range: (0,030 – 2,0) mg/l Spectrophotometric method PN-EN 26777:1999
7 生活饮用水 Ammonium ion concentration Range: (0,12 – 1,0) mg/l Spectrophotometric method PN-ISO 7150-1:2002
8 生活饮用水 Manganese concentration Range: (0,030 – 1,0) mg/l Spectrophotometric method PB-01 wydanie 6 z dnia 28.02.2019 r. na podstawie testu Merck 114770
9 生活饮用水 Free chlorine concentration Range: (0,08 – 1,00) mg/l Spectrophotometric method PB-07 wydanie 1 z dnia 28.12.2009 r. na podstawie metodyki z odczynnikiem DPD
10 生活饮用水 Permanganate index Range: (0,6 – 10) mg/l O 2 Titrimetric method PN-EN ISO 8467:2001
11 生活饮用水 Aluminium concentration Range: (0,05 – 0,4) mg/l Spectrophotometric method PB-16 wydanie 2 z dnia 31.05.2013 r. na podstawie testu Hach Lange LCK 301
12 生活饮用水 Total calcium and magnesium content (total hardness) Range: (18 – 500) mg/l CaCO 3 Titrimetric method PN-ISO 6059:1999
13 生活饮用水 Total viable count at 22 °C Plate method (pour plate) PN-EN ISO 6222:2004
14 生活饮用水 Total viable count at 36 °C Plate method (pour plate)
15 生活饮用水 Most probable number of intestinal enterococci MPN method PB-19 wydanie 3 z dnia 27.02.2019 r. na podstawie testu Idexx Enterolert-DW
16 生活饮用水 Most probable number of coliform bacteria MPN method PN-EN ISO 9308-2:2014-06
17 生活饮用水 Most probable number of Escherichia coli MPN method
18 生活饮用水 微生物检测用样品采集 PN-EN ISO 19458:2007
19 生活饮用水 肠球菌计数 膜过滤法 PN-EN ISO 7899-2:2004
20 Water intended for human consumption Wastewater pH Range: 2,0 – 11,0 Potentiometric method PN-EN ISO 10523:2012
21 Water intended for human consumption Wastewater Chloride concentration Range: (10,0 – 400) mg/l Titrimetric method PN-ISO 9297:1994
22 Water intended for human consumption Wastewater Iron concentration Range: (0,050 – 5,00) mg/l Spectrophotometric method PN-ISO 6332:2001 p. 7.1.1 +Ap1:2016-06
23 Rainwater and snowmelt water Sampling for chemical and physical testing Manual method PN-ISO 5667-10:2021-11
24 Rainwater and snowmelt water Total suspended solids Range: (2,0 – 200) mg/l Gravimetric method PN-EN 872:2007+Ap1:2007
25 污水 Sampling for chemical and physical testing Manual method Automatic method Temperature of wastewater/of the wastewater sample taken Range: (1,0 – 40,0) °C PN-ISO 5667-10:2021-11 PN-77/C-04584
26 污水 Total suspended solids (TSS) Range: (2,0 – 1000) mg/l Gravimetric method PN-EN 872:2007+Ap1:2007
27 污水 Biochemical oxygen demand - BOD 5 Range: (3 – 3000) mg/l O 2 Electrochemical method PN-EN ISO 5815-1:2019-12
28 污水 Biochemical oxygen demand - BOD 5 Range: (2,0 – 6,0) mg/l O 2 Electrochemical method PN-EN 1899-2:2002
29 污水 Chemical oxygen demand - COD-Cr Range: (20,0 – 5000) mg/l O 2 Spectrophotometric method PN-ISO 15705:2005
30 污水 Total phosphorus concentration Range: (0,20 – 25,0) mg/l Spectrophotometric method PN-EN ISO 6878:2006 p. 7 +Ap1:2010+Ap2:2010
31 污水 Nitrate nitrogen concentration Range: (0,100 – 20,0) mg/l Spectrophotometric method PN-82/C-04576.08
32 污水 Nitrite nitrogen concentration Range: (0,0036 – 2,58) mg/l Spectrophotometric method PN-EN 26777:1999
33 污水 Kjeldahl nitrogen concentration Range: (1,0 – 250) mg/l Titrimetric method PN-EN 25663:2001
34 污水 Total nitrogen (calculated) PB-20 wydanie 1 z dnia 01.02.2019 r.

引用标准 (29)

PB-01 wydanie 6 z dnia 28.02.2019 r. na podstawie testu Merck 114770
PB-07 wydanie 1 z dnia 28.12.2009 r. na podstawie metodyki z odczynnikiem DPD
PB-16 wydanie 2 z dnia 31.05.2013 r. na podstawie testu Hach Lange LCK 301
PB-19 wydanie 3 z dnia 27.02.2019 r. na podstawie testu Idexx Enterolert-DW
PB-20 wydanie 1 z dnia 01.02.2019 r.
PN-82/C-04576.08
PN-EN 1899-2:2002
PN-EN 25663:2001
PN-EN 26777:1999
PN-EN 27888:1999
PN-EN 872:2007+Ap1:2007
PN-EN ISO 10523:2012
PN-EN ISO 19458:2007
PN-EN ISO 5815-1:2019-12
PN-EN ISO 6222:2004
PN-EN ISO 6878:2006 p. 7 +Ap1:2010+Ap2:2010
PN-EN ISO 7027-1:2016-09
PN-EN ISO 7887:2012 metoda C +Ap1:2015-06
PN-EN ISO 7899-2:2004
PN-EN ISO 8467:2001
PN-EN ISO 9308-2:2014-06
PN-ISO 15705:2005
PN-ISO 5667-10:2021-11
PN-ISO 5667-10:2021-11 PN-77/C-04584
PN-ISO 5667-5:2017-10
PN-ISO 6059:1999
PN-ISO 6332:2001 p. 7.1.1 +Ap1:2016-06
PN-ISO 7150-1:2002
PN-ISO 9297:1994