🇵🇱 WOJSKOWY OŚRODEK MEDYCYNY PREWENCYJNEJ PL

PCA AB 1042 • Wrocław, 波兰 • 48 项方法

环境水与废水汽车

WOJSKOWY OŚRODEK MEDYCYNY PREWENCYJNEJ 是由 PCA 认可的实验室,认可编号 AB 1042(Wrocław,波兰)。认可范围涵盖 48 项检测方法,涉及以下领域:环境、水与废水、汽车。检测对象包括:生活饮用水、Workplace environment - electromagnetic field in the workspace from…、Workplace environment - electromagnetic field in the workspace orig…、工作场所环境 — 空气。

要点速览

  • 认可编号: PCA AB 1042
  • 认可范围内方法数: 48
  • 检测对象种类: 20
  • 城市: Wrocław, 波兰
认可编号
AB 1042
认可机构
PCA
地址
WE WROCŁAWIU, ZESPÓŁ LABORATORYJNY, ul. Ślężna 158
城市
Wrocław, 波兰

该实验室检测什么 (20)

认可范围 — 项检测方法 (48)

序号 检测对象 方法 / 参数 技术 依据文件
检测方法
1 工作场所环境 — 室内电气照明 Illuminance Range: (5-10 000) lx Direct measurement method PN-83/E-4040.03 PB-01/LBŚP wydanie 3 z 07.03.2023 r.
2 工作场所环境 — 室内电气照明 Lighting uniformity ( calculated)
3 工作场所环境 — 噪声 A-weighted equivalent sound level A-weighted maximum sound level Range: (35 – 135) dB C-weighted peak sound level Range: (35 – 135) dB Direct measurement method PN-N-01307:1994 PN-ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2
4 工作场所环境 — 噪声 噪声暴露级,参照: — 8 小时日工作时间 — 平均每周工作时间(计算值)
5 工作场所环境 — 空气 Air sampling for occupational exposure assessment to dust agents - inhalable fraction Personal dosimetry method PN-Z-04008-7:2002
6 工作场所环境 — 空气 暴露指数(计算得出)
7 工作场所环境 — 空气 Concentration of harmful dust agents - inhalable fraction - wood dust Range (0,30 – 30,0) mg/m3 Gravimetric method PN-Z-04507:2022-05 PN-Z-04507:2022-05/Ap1:2022-08
8 工作场所环境 — 中等微气候 Air temperature Range: (5 – 40) °C Black globe temperature Range: (5 – 40) °C Air humidity Range: (25 – 80) % Air velocity Range: (0,15 – 5,0) m/s Direct measurement method PN-EN ISO 7730:2006 + Ap:2016-04
9 工作场所环境 — 中等微气候 PMV 指数 PPD 指数(计算值)
10 Workplace environment - electromagnetic field in the workspace from stationary communication equipment Electric field strength: - in the frequency range from 1,6 MHz to 300 MHz range: (0,50 – 800) V/m - in the frequency range from 300 MHz to 600 MHz range: (1,0 - 400) V/m Direct measurement method NO-06-A215-2 | ena Pracy. Ochrona przed promieniowaniem elektromagnetycznym. Część 2: Metody badań
11 Workplace environment - electromagnetic field in the workspace from stationary communication equipment Magnetic field strength - from 1,6 MHz to 600 MHz Range: (0,01 – 15,0) A/m Direct measurement method
12 Workplace environment - electromagnetic field in the workspace from vehicles with communication equipment Electric field strength: - in the frequency range from 1,6 MHz to 300 MHz range: (0,50 – 800) V/m - in the frequency range from 300 MHz to 18 GHz range: (1,0 - 400) V/m Direct measurement method NO-06-A215-2 | ena Pracy. Ochrona przed promieniowaniem elektromagnetycznym. Część 2: Metody badań
13 Workplace environment - electromagnetic field in the workspace from vehicles with communication equipment Magnetic field strength from 1,6 MHz to 1 GHz Range: (0,01 – 15,0) A/m Direct measurement method
14 Workplace environment - electromagnetic field in the workspace from vehicles with communication equipment Magnetic field strength from 1 GHz to 18 GHz (calculated)
15 Workplace environment - electromagnetic field in the workspace from hand-held and portable communication devices Electric field strength - in the frequency range from 1,6 MHz to 300 MHz range: (0,50 – 800) V/m - in the frequency range from 300 MHz to 600 MHz range: (1,0 - 400) V/m Direct measurement method NO-06-A215-2 | ena Pracy. Ochrona przed promieniowaniem elektromagnetycznym. Część 2: Metody badań
16 Workplace environment - electromagnetic field in the workspace from hand-held and portable communication devices Magnetic field strength - from 1,6 MHz to 10 MHz range: (0,02 - 110) A/m - from 10 MHz to 30 MHz range: (0,02 - 15) A/m - from 27 MHz to 600 MHz range: (0,01 – 2,0) A/m Direct measurement method
17 Workplace environment - electromagnetic field in the workspace from measurement and control apparatus Electric field strength - in the frequency range from 1,6 MHz to 300 MHz range: (0,50 – 800) V/m - in the frequency range from 300 MHz to 1 GHz Range: (1,0 - 400) V/m Direct measurement method NO-06-A215-2 | ena Pracy. Ochrona przed promieniowaniem elektromagnetycznym. Część 2: Metody badań
18 Workplace environment - electromagnetic field in the workspace from measurement and control apparatus Magnetic field strength from 1,6 MHz to 1 GHz range: (0,015 – 15) A/m Direct measurement method
19 Workplace environment - electromagnetic field in the workspace originating from mobile communication devices Electric field strength: - in the frequency range from 1,6 MHz to 300 MHz range: (0,50 – 800) V/m - in the frequency range from 300 MHz to 18 GHz range: (1,0 - 400) V/m Direct measurement method NO-06-A215-2 | ena Pracy. Ochrona przed promieniowaniem elektromagnetycznym. Część 2: Metody badań
20 Workplace environment - electromagnetic field in the workspace originating from mobile communication devices Magnetic field strength from 1,6 MHz to 1 GHz Range: (0,01 – 15,0) A/m Direct measurement method
21 Workplace environment - electromagnetic field in the workspace originating from mobile communication devices Magnetic field strength from 1 GHz to 18 GHz (calculated)
22 Workplace environment - electromagnetic field in the workspace from medical magnetotherapy equipment Magnetic flux density in the frequency range - from 20 Hz to 50 Hz range: (0,020 – 50,0) mT Direct (simplified) measurement method Magnetic field strength in the frequency range from 20 Hz to 50 Hz (calculated) Podstawy i Metodyki Oceny Środowiska Pracy 2016, nr 4, s. 151- 180
23 Canned products in metal packaging – meat and meat products Shelf stability of canned products Incubation method PN-A-82055-5:1994 z wyłączeniem punktu 2.5.3. z wyłączeniem pobierania próbek
24 Canned products in metal packaging – meat and meat products Leak tightness of cans Vacuum method PN-A-82055-4:1997+Az1:2002 z wyłączeniem punktu 2.4.1.3
25 Canned products in tin packaging – fruit, vegetable and vegetable-meat preserves Shelf stability of canned products Incubation method PN-90/A-75052/03
26 Canned products in tin packaging – fruit, vegetable and vegetable-meat preserves Leak tightness of cans Vacuum method PN-90/A-75052/02 z wyłączeniem punktu 2.2.3
27 Canned products in tin packaging – canned fish Shelf stability of canned products Incubation method PN – 92/A-86732 pkt. 2.3.11. z wyłączeniem pobierania próbek
28 Canned products in tin packaging – canned fish Leak tightness of cans Vacuum method PN – 92/A-86732 pkt. 2.3.10. z wyłączeniem pobierania próbek
29 Canned products in hermetically sealed packaging Sterilised soups Shelf stability of canned products Incubation method NO-89-A208:2015 p.4.6 PN – 90/A – 75052 -03
30 Canned products in hermetically sealed packaging Sterilised soups Leak tightness of cans Vacuum method NO-89-A208:2015 p.4.7
31 Canned products in hermetically sealed packaging Sterilised canned poultry Shelf stability of canned products Incubation method NO-89-A203 | PN-A-82055-5:1994 z wyłączeniem punktu 2.5.3. z wyłączeniem pobierania próbek
32 Canned products in hermetically sealed packaging Sterilised canned poultry Leak tightness of cans Vacuum method NO-89-A203 | PN-A-82055-4:1997 + Az1:2002 z wyłączeniem pkt 2.4.1.3.
33 Canned products in hermetically sealed packaging Sterilised canned vegetable – meat and meatless products Shelf stability of canned products Incubation method NO-89-A202:2015 p.4.6 PN - 90/A - 75052-03:1990
34 Canned products in hermetically sealed packaging Sterilised canned vegetable – meat and meatless products Leak tightness of cans Vacuum method NO-89-A202:2015 p.4.7
35 Canned products in hermetically sealed packaging Sterilised canned meat Shelf stability of canned products Incubation method NO-89-A201 | PN-A-82055-5:1994 z wyłączeniem punktu 2.5.3 z wyłączeniem pobierania próbek
36 Canned products in hermetically sealed packaging Sterilised canned meat Leak tightness of cans Vacuum method NO-89-A201 | PN-A-82055 - 4:1997 + Az1:2002 z wyłączeniem pkt 2.4.1.3
37 生活饮用水 pH Range: 4 – 10 Potentiometric method EN ISO 10523:2012
38 生活饮用水 Specific conductivity Range: (100 – 1500) μS/cm Conductometric method PN-EN 27888:1999
39 生活饮用水 Turbidity Range: (0, 1 – 40) NTU Nephelometric method PN-EN ISO 7027-1:2016-09
40 生活饮用水 Iron concentration Range: (0,02– 1,0) mg/l Spectrophotometric method PB - 07/ LBŻiW wyd. 7 z dn. 22.11.2016 r.
41 生活饮用水 Manganese concentration Range: (0,02 – 0,1) mg/l Spectrophotometric method PB - 06/ LBŻiW wyd.7 z dn. 22.11.2016 r.
42 生活饮用水 Nitrite nitrogen concentration Range: (0,01 – 0,15) mg/l Spectrophotometric method PB - 04/LBŻiW wyd. 8 z dn. 22.03.2024 r.
43 生活饮用水 Nitrite concentration Range: (0,033 – 0,495) mg/l (calculated)
44 生活饮用水 Ammonium nitrogen concentration Range: (0,03 – 0,40) mg/l Spectrophotometric method PB - 02/LBŻiW wyd. 8 z dn. 22.03.2024 r.
45 生活饮用水 Ammonium ion concentration Range: (0,04– 0,52) mg/l (calculated)
46 生活饮用水 22 °C 微生物总数 平板法(倾注培养) PN-EN ISO 6222:2004
47 游泳池水 36 °C 微生物总数 平板法(倾注培养) PN-EN ISO 6222:2004
48 粪便、肛拭子 Presence of rods of the genus Salmonella, Shigella Culture method with biochemical and serological confirmation Procedura badawcza Nr PB – 01/LM wydanie nr 7 z dnia 15.03.2022 r. w oparciu o Rekomendacje Narodowego Instytutu Zdrowia Publicznego, PZH i KIDL, Warszawa 2015

引用标准 (32)

EN ISO 10523:2012
NO-06-A215-2
NO-89-A201
NO-89-A202:2015 p.4.6 PN - 90/A - 75052-03:1990
NO-89-A202:2015 p.4.7
NO-89-A203
NO-89-A208:2015 p.4.6 PN – 90/A – 75052 -03
NO-89-A208:2015 p.4.7
PB - 02/LBŻiW wyd. 8 z dn. 22.03.2024 r.
PB - 04/LBŻiW wyd. 8 z dn. 22.03.2024 r.
PB - 06/ LBŻiW wyd.7 z dn. 22.11.2016 r.
PB - 07/ LBŻiW wyd. 7 z dn. 22.11.2016 r.
PN – 92/A-86732 pkt. 2.3.10. z wyłączeniem pobierania próbek
PN – 92/A-86732 pkt. 2.3.11. z wyłączeniem pobierania próbek
PN-83/E-4040.03 PB-01/LBŚP wydanie 3 z 07.03.2023 r.
PN-90/A-75052/02 z wyłączeniem punktu 2.2.3
PN-90/A-75052/03
PN-A-82055 - 4:1997 + Az1:2002 z wyłączeniem pkt 2.4.1.3
PN-A-82055-4:1997 + Az1:2002 z wyłączeniem pkt 2.4.1.3.
PN-A-82055-4:1997+Az1:2002 z wyłączeniem punktu 2.4.1.3
PN-A-82055-5:1994 z wyłączeniem punktu 2.5.3 z wyłączeniem pobierania próbek
PN-A-82055-5:1994 z wyłączeniem punktu 2.5.3. z wyłączeniem pobierania próbek
PN-EN 27888:1999
PN-EN ISO 6222:2004
PN-EN ISO 7027-1:2016-09
PN-EN ISO 7730:2006 + Ap:2016-04
PN-N-01307:1994 PN-ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2
PN-Z-04008-7:2002
PN-Z-04507:2022-05 PN-Z-04507:2022-05/Ap1:2022-08
Podstawy i Metodyki Oceny Środowiska Pracy 2016, nr 4, s. 151- 180
Procedura badawcza Nr PB – 01/LM wydanie nr 7 z dnia 15.03.2022 r. w oparciu o Rekomendacje Narodowego Instytutu Zdrowia Publicznego, PZH i KIDL, Warszawa 2015
ena Pracy. Ochrona przed promieniowaniem elektromagnetycznym. Część 2: Metody badań