🇵🇱 WOJSKOWY OŚRODEK MEDYCYNY PREWENCYJNEJ PL
环境水与废水汽车
WOJSKOWY OŚRODEK MEDYCYNY PREWENCYJNEJ 是由 PCA 认可的实验室,认可编号 AB 1042(Wrocław,波兰)。认可范围涵盖 48 项检测方法,涉及以下领域:环境、水与废水、汽车。检测对象包括:生活饮用水、Workplace environment - electromagnetic field in the workspace from…、Workplace environment - electromagnetic field in the workspace orig…、工作场所环境 — 空气。
要点速览
- 认可编号: PCA AB 1042
- 认可范围内方法数: 48
- 检测对象种类: 20
- 城市: Wrocław, 波兰
- 认可编号
- AB 1042
- 认可机构
- PCA
- 地址
- WE WROCŁAWIU, ZESPÓŁ LABORATORYJNY, ul. Ślężna 158
- 城市
- Wrocław, 波兰
该实验室检测什么 (20)
- 生活饮用水 — 10 项方法
- Workplace environment - electromagnetic field in the workspace from vehicles with communication equipment — 3 项方法
- Workplace environment - electromagnetic field in the workspace originating from mobile communication devices — 3 项方法
- 工作场所环境 — 空气 — 3 项方法
- Canned products in hermetically sealed packaging Sterilised canned meat — 2 项方法
- Canned products in hermetically sealed packaging Sterilised canned poultry — 2 项方法
- Canned products in hermetically sealed packaging Sterilised canned vegetable – meat and meatless products — 2 项方法
- Canned products in hermetically sealed packaging Sterilised soups — 2 项方法
- Canned products in metal packaging – meat and meat products — 2 项方法
- Canned products in tin packaging – canned fish — 2 项方法
- Canned products in tin packaging – fruit, vegetable and vegetable-meat preserves — 2 项方法
- Workplace environment - electromagnetic field in the workspace from hand-held and portable communication devices — 2 项方法
- Workplace environment - electromagnetic field in the workspace from measurement and control apparatus — 2 项方法
- Workplace environment - electromagnetic field in the workspace from stationary communication equipment — 2 项方法
- 工作场所环境 — 中等微气候 — 2 项方法
- 另有 5 项
认可范围 — 项检测方法 (48)
| 序号 | 检测对象 | 方法 / 参数 | 技术 | 依据文件 | |
|---|---|---|---|---|---|
| 检测方法 | |||||
| 1 | 工作场所环境 — 室内电气照明 | Illuminance Range: (5-10 000) lx Direct measurement method | PN-83/E-4040.03 PB-01/LBŚP wydanie 3 z 07.03.2023 r. | ||
| 2 | 工作场所环境 — 室内电气照明 | Lighting uniformity ( calculated) | |||
| 3 | 工作场所环境 — 噪声 | A-weighted equivalent sound level A-weighted maximum sound level Range: (35 – 135) dB C-weighted peak sound level Range: (35 – 135) dB Direct measurement method | PN-N-01307:1994 PN-ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2 | ||
| 4 | 工作场所环境 — 噪声 | 噪声暴露级,参照: — 8 小时日工作时间 — 平均每周工作时间(计算值) | |||
| 5 | 工作场所环境 — 空气 | Air sampling for occupational exposure assessment to dust agents - inhalable fraction Personal dosimetry method | PN-Z-04008-7:2002 | ||
| 6 | 工作场所环境 — 空气 | 暴露指数(计算得出) | |||
| 7 | 工作场所环境 — 空气 | Concentration of harmful dust agents - inhalable fraction - wood dust Range (0,30 – 30,0) mg/m3 Gravimetric method | PN-Z-04507:2022-05 PN-Z-04507:2022-05/Ap1:2022-08 | ||
| 8 | 工作场所环境 — 中等微气候 | Air temperature Range: (5 – 40) °C Black globe temperature Range: (5 – 40) °C Air humidity Range: (25 – 80) % Air velocity Range: (0,15 – 5,0) m/s Direct measurement method | PN-EN ISO 7730:2006 + Ap:2016-04 | ||
| 9 | 工作场所环境 — 中等微气候 | PMV 指数 PPD 指数(计算值) | |||
| 10 | Workplace environment - electromagnetic field in the workspace from stationary communication equipment | Electric field strength: - in the frequency range from 1,6 MHz to 300 MHz range: (0,50 – 800) V/m - in the frequency range from 300 MHz to 600 MHz range: (1,0 - 400) V/m Direct measurement method | NO-06-A215-2 | ena Pracy. Ochrona przed promieniowaniem elektromagnetycznym. Część 2: Metody badań | ||
| 11 | Workplace environment - electromagnetic field in the workspace from stationary communication equipment | Magnetic field strength - from 1,6 MHz to 600 MHz Range: (0,01 – 15,0) A/m Direct measurement method | |||
| 12 | Workplace environment - electromagnetic field in the workspace from vehicles with communication equipment | Electric field strength: - in the frequency range from 1,6 MHz to 300 MHz range: (0,50 – 800) V/m - in the frequency range from 300 MHz to 18 GHz range: (1,0 - 400) V/m Direct measurement method | NO-06-A215-2 | ena Pracy. Ochrona przed promieniowaniem elektromagnetycznym. Część 2: Metody badań | ||
| 13 | Workplace environment - electromagnetic field in the workspace from vehicles with communication equipment | Magnetic field strength from 1,6 MHz to 1 GHz Range: (0,01 – 15,0) A/m Direct measurement method | |||
| 14 | Workplace environment - electromagnetic field in the workspace from vehicles with communication equipment | Magnetic field strength from 1 GHz to 18 GHz (calculated) | |||
| 15 | Workplace environment - electromagnetic field in the workspace from hand-held and portable communication devices | Electric field strength - in the frequency range from 1,6 MHz to 300 MHz range: (0,50 – 800) V/m - in the frequency range from 300 MHz to 600 MHz range: (1,0 - 400) V/m Direct measurement method | NO-06-A215-2 | ena Pracy. Ochrona przed promieniowaniem elektromagnetycznym. Część 2: Metody badań | ||
| 16 | Workplace environment - electromagnetic field in the workspace from hand-held and portable communication devices | Magnetic field strength - from 1,6 MHz to 10 MHz range: (0,02 - 110) A/m - from 10 MHz to 30 MHz range: (0,02 - 15) A/m - from 27 MHz to 600 MHz range: (0,01 – 2,0) A/m Direct measurement method | |||
| 17 | Workplace environment - electromagnetic field in the workspace from measurement and control apparatus | Electric field strength - in the frequency range from 1,6 MHz to 300 MHz range: (0,50 – 800) V/m - in the frequency range from 300 MHz to 1 GHz Range: (1,0 - 400) V/m Direct measurement method | NO-06-A215-2 | ena Pracy. Ochrona przed promieniowaniem elektromagnetycznym. Część 2: Metody badań | ||
| 18 | Workplace environment - electromagnetic field in the workspace from measurement and control apparatus | Magnetic field strength from 1,6 MHz to 1 GHz range: (0,015 – 15) A/m Direct measurement method | |||
| 19 | Workplace environment - electromagnetic field in the workspace originating from mobile communication devices | Electric field strength: - in the frequency range from 1,6 MHz to 300 MHz range: (0,50 – 800) V/m - in the frequency range from 300 MHz to 18 GHz range: (1,0 - 400) V/m Direct measurement method | NO-06-A215-2 | ena Pracy. Ochrona przed promieniowaniem elektromagnetycznym. Część 2: Metody badań | ||
| 20 | Workplace environment - electromagnetic field in the workspace originating from mobile communication devices | Magnetic field strength from 1,6 MHz to 1 GHz Range: (0,01 – 15,0) A/m Direct measurement method | |||
| 21 | Workplace environment - electromagnetic field in the workspace originating from mobile communication devices | Magnetic field strength from 1 GHz to 18 GHz (calculated) | |||
| 22 | Workplace environment - electromagnetic field in the workspace from medical magnetotherapy equipment | Magnetic flux density in the frequency range - from 20 Hz to 50 Hz range: (0,020 – 50,0) mT Direct (simplified) measurement method Magnetic field strength in the frequency range from 20 Hz to 50 Hz (calculated) | Podstawy i Metodyki Oceny Środowiska Pracy 2016, nr 4, s. 151- 180 | ||
| 23 | Canned products in metal packaging – meat and meat products | Shelf stability of canned products Incubation method | PN-A-82055-5:1994 z wyłączeniem punktu 2.5.3. z wyłączeniem pobierania próbek | ||
| 24 | Canned products in metal packaging – meat and meat products | Leak tightness of cans Vacuum method | PN-A-82055-4:1997+Az1:2002 z wyłączeniem punktu 2.4.1.3 | ||
| 25 | Canned products in tin packaging – fruit, vegetable and vegetable-meat preserves | Shelf stability of canned products Incubation method | PN-90/A-75052/03 | ||
| 26 | Canned products in tin packaging – fruit, vegetable and vegetable-meat preserves | Leak tightness of cans Vacuum method | PN-90/A-75052/02 z wyłączeniem punktu 2.2.3 | ||
| 27 | Canned products in tin packaging – canned fish | Shelf stability of canned products Incubation method | PN – 92/A-86732 pkt. 2.3.11. z wyłączeniem pobierania próbek | ||
| 28 | Canned products in tin packaging – canned fish | Leak tightness of cans Vacuum method | PN – 92/A-86732 pkt. 2.3.10. z wyłączeniem pobierania próbek | ||
| 29 | Canned products in hermetically sealed packaging Sterilised soups | Shelf stability of canned products Incubation method | NO-89-A208:2015 p.4.6 PN – 90/A – 75052 -03 | ||
| 30 | Canned products in hermetically sealed packaging Sterilised soups | Leak tightness of cans Vacuum method | NO-89-A208:2015 p.4.7 | ||
| 31 | Canned products in hermetically sealed packaging Sterilised canned poultry | Shelf stability of canned products Incubation method | NO-89-A203 | PN-A-82055-5:1994 z wyłączeniem punktu 2.5.3. z wyłączeniem pobierania próbek | ||
| 32 | Canned products in hermetically sealed packaging Sterilised canned poultry | Leak tightness of cans Vacuum method | NO-89-A203 | PN-A-82055-4:1997 + Az1:2002 z wyłączeniem pkt 2.4.1.3. | ||
| 33 | Canned products in hermetically sealed packaging Sterilised canned vegetable – meat and meatless products | Shelf stability of canned products Incubation method | NO-89-A202:2015 p.4.6 PN - 90/A - 75052-03:1990 | ||
| 34 | Canned products in hermetically sealed packaging Sterilised canned vegetable – meat and meatless products | Leak tightness of cans Vacuum method | NO-89-A202:2015 p.4.7 | ||
| 35 | Canned products in hermetically sealed packaging Sterilised canned meat | Shelf stability of canned products Incubation method | NO-89-A201 | PN-A-82055-5:1994 z wyłączeniem punktu 2.5.3 z wyłączeniem pobierania próbek | ||
| 36 | Canned products in hermetically sealed packaging Sterilised canned meat | Leak tightness of cans Vacuum method | NO-89-A201 | PN-A-82055 - 4:1997 + Az1:2002 z wyłączeniem pkt 2.4.1.3 | ||
| 37 | 生活饮用水 | pH Range: 4 – 10 Potentiometric method | EN ISO 10523:2012 | ||
| 38 | 生活饮用水 | Specific conductivity Range: (100 – 1500) μS/cm Conductometric method | PN-EN 27888:1999 | ||
| 39 | 生活饮用水 | Turbidity Range: (0, 1 – 40) NTU Nephelometric method | PN-EN ISO 7027-1:2016-09 | ||
| 40 | 生活饮用水 | Iron concentration Range: (0,02– 1,0) mg/l Spectrophotometric method | PB - 07/ LBŻiW wyd. 7 z dn. 22.11.2016 r. | ||
| 41 | 生活饮用水 | Manganese concentration Range: (0,02 – 0,1) mg/l Spectrophotometric method | PB - 06/ LBŻiW wyd.7 z dn. 22.11.2016 r. | ||
| 42 | 生活饮用水 | Nitrite nitrogen concentration Range: (0,01 – 0,15) mg/l Spectrophotometric method | PB - 04/LBŻiW wyd. 8 z dn. 22.03.2024 r. | ||
| 43 | 生活饮用水 | Nitrite concentration Range: (0,033 – 0,495) mg/l (calculated) | |||
| 44 | 生活饮用水 | Ammonium nitrogen concentration Range: (0,03 – 0,40) mg/l Spectrophotometric method | PB - 02/LBŻiW wyd. 8 z dn. 22.03.2024 r. | ||
| 45 | 生活饮用水 | Ammonium ion concentration Range: (0,04– 0,52) mg/l (calculated) | |||
| 46 | 生活饮用水 | 22 °C 微生物总数 平板法(倾注培养) | PN-EN ISO 6222:2004 | ||
| 47 | 游泳池水 | 36 °C 微生物总数 平板法(倾注培养) | PN-EN ISO 6222:2004 | ||
| 48 | 粪便、肛拭子 | Presence of rods of the genus Salmonella, Shigella Culture method with biochemical and serological confirmation | Procedura badawcza Nr PB – 01/LM wydanie nr 7 z dnia 15.03.2022 r. w oparciu o Rekomendacje Narodowego Instytutu Zdrowia Publicznego, PZH i KIDL, Warszawa 2015 | ||
引用标准 (32)
EN ISO 10523:2012
NO-06-A215-2
NO-89-A201
NO-89-A202:2015 p.4.6 PN - 90/A - 75052-03:1990
NO-89-A202:2015 p.4.7
NO-89-A203
NO-89-A208:2015 p.4.6 PN – 90/A – 75052 -03
NO-89-A208:2015 p.4.7
PB - 02/LBŻiW wyd. 8 z dn. 22.03.2024 r.
PB - 04/LBŻiW wyd. 8 z dn. 22.03.2024 r.
PB - 06/ LBŻiW wyd.7 z dn. 22.11.2016 r.
PB - 07/ LBŻiW wyd. 7 z dn. 22.11.2016 r.
PN – 92/A-86732 pkt. 2.3.10. z wyłączeniem pobierania próbek
PN – 92/A-86732 pkt. 2.3.11. z wyłączeniem pobierania próbek
PN-83/E-4040.03 PB-01/LBŚP wydanie 3 z 07.03.2023 r.
PN-90/A-75052/02 z wyłączeniem punktu 2.2.3
PN-90/A-75052/03
PN-A-82055 - 4:1997 + Az1:2002 z wyłączeniem pkt 2.4.1.3
PN-A-82055-4:1997 + Az1:2002 z wyłączeniem pkt 2.4.1.3.
PN-A-82055-4:1997+Az1:2002 z wyłączeniem punktu 2.4.1.3
PN-A-82055-5:1994 z wyłączeniem punktu 2.5.3 z wyłączeniem pobierania próbek
PN-A-82055-5:1994 z wyłączeniem punktu 2.5.3. z wyłączeniem pobierania próbek
PN-EN 27888:1999
PN-EN ISO 6222:2004
PN-EN ISO 7027-1:2016-09
PN-EN ISO 7730:2006 + Ap:2016-04
PN-N-01307:1994 PN-ISO 9612:2011 z wyłączeniem metody obejmującej strategię 2
PN-Z-04008-7:2002
PN-Z-04507:2022-05 PN-Z-04507:2022-05/Ap1:2022-08
Podstawy i Metodyki Oceny Środowiska Pracy 2016, nr 4, s. 151- 180
Procedura badawcza Nr PB – 01/LM wydanie nr 7 z dnia 15.03.2022 r. w oparciu o Rekomendacje Narodowego Instytutu Zdrowia Publicznego, PZH i KIDL, Warszawa 2015
ena Pracy. Ochrona przed promieniowaniem elektromagnetycznym. Część 2: Metody badań