🇵🇱 LABORATORIUM OCHRONY ŚRODOWISKA PRACY Sp. z o.o. PL

PCA AB 1037 • Siedlce, 波兰 • 28 项方法

环境建筑材料与高分子

LABORATORIUM OCHRONY ŚRODOWISKA PRACY Sp. z o.o. 是由 PCA 认可的实验室,认可编号 AB 1037(Siedlce,波兰)。认可范围涵盖 28 项检测方法,涉及以下领域:环境、建筑、材料与高分子。检测对象包括:工作场所环境 — 空气、Workplace environment - air, - air samples collected on filters、Workplace environment - air, - air samples collected into absorbing…、工作场所环境 — 中等微气候。

要点速览

  • 认可编号: PCA AB 1037
  • 认可范围内方法数: 28
  • 检测对象种类: 9
  • 城市: Siedlce, 波兰
认可编号
AB 1037
认可机构
PCA
地址
ul. Starzyńskiego 1, 08-110 Siedlce
城市
Siedlce, 波兰

该实验室检测什么 (9)

认可范围 — 项检测方法 (28)

序号 检测对象 方法 / 参数 技术 依据文件
检测方法
1 工作场所环境 — 噪声 A-weighted equivalent sound level A-weighted maximum sound level Range: (35 - 135) dB C-weighted peak sound level Range: (35 - 138) dB Direct measurement method PN-N-01307:1994 PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 3 – punkt 11
2 工作场所环境 — 噪声 Noise exposure level normalised to: - an 8-hour working day and the corresponding daily exposure - an average weekly working time (calculated)
3 工作场所环境 — 手传振动 Frequency-weighted r.m.s. vibration acceleration Range: (0,2 - 100) m/s2 Direct measurement method PN-EN ISO 5349-1:2004 PN-EN ISO 5349-2:2004 PN-EN ISO 5349-2:2004/A1:2015-11
4 工作场所环境 — 手传振动 Daily exposure, expressed as the energy-equivalent for 8 hours of the vector sum of the r.m.s. frequency-weighted vibration accelerations determined for the three directional components (ahwx, ahwy, ahwz) Exposure lasting 30 minutes or less, expressed as the vector sum of the r.m.s. frequency-weighted vibration accelerations determined for the three directional components (ahwx, ahwy, ahwz) (calculated)
5 工作场所环境 — 全身振动 Frequency-weighted effective vibration acceleration Range: (0,04 - 120) m/s2 Direct measurement method PN-EN 14253+A1:2011
6 工作场所环境 — 全身振动 Daily exposure, expressed as the energy-equivalent value for 8 hours of action of the r.m.s. frequency-corrected vibration acceleration dominant among the vibration accelerations determined for three directional components taking into account the appropriate factors (1.4awx, 1.4awy, awz) Exposure lasting 30 minutes or less, expressed as the r.m.s. frequency-weighted vibration acceleration dominant among the vibration accelerations determined for three directional components taking into account the appropriate factors (1.4awx, 1.4awy, awz) (calculated)
7 工作场所环境 — 高温微气候 Air temperature Range: (10 - 40) oC Natural wet bulb temperature Range: (10 - 40) oC Blackened globe temperature Range: (10 - 40) oC Direct measurement method PN-EN ISO 7243:2018-01
8 工作场所环境 — 高温微气候 WBGT index WBGTeff index (calculated)
9 工作场所环境 — 中等微气候 Air temperature Range: (-20 - 40) oC Blackened globe temperature Range: (-20 - 40) oC Air humidity Range: (30 - 85) % Air velocity Range: (0,15 - 10) m/s Direct measurement method PN-EN ISO 7730:2006 PN-EN ISO 7730:2006+Ap2:2016-04
10 工作场所环境 — 中等微气候 PMV 指数 PPD 指数(计算值)
11 工作场所环境 — 低温微气候 Air temperature Range: (-20 - 10) oC Blackened globe temperature Range: (-20 - 10) oC Air humidity Range: (30 - 85) % Air velocity Range: (0,4 - 10) m/s Direct measurement method PN-EN ISO 11079:2008+Ap1:2013
12 工作场所环境 — 低温微气候 IREQmin index IREQneutral index twc index (calculated)
13 工作场所环境 — 空气 Sampling for occupational exposure assessment to: - dust agents inhalable fraction respirable fraction - metals and their compounds, including inhalable fraction respirable fraction Personal dosimetry method PN-Z-04008-7:2002+Az1:2004
14 工作场所环境 — 空气 Sampling for occupational exposure assessment to: - organic substances, including inhalable fraction - inorganic substances, including inhalable fraction respirable fraction thoracic fraction Personal dosimetry method Stationary method
15 工作场所环境 — 空气 暴露指数(计算得出)
16 工作场所环境 — 空气 Concentration of harmful dust agents – inhalable fraction: - Petroleum asphalt - Apatites and phosphorites - Portland cement - Titanium dioxide - Natural graphite - Synthetic graphite - Kaolin - Amorphous and synthetic silica: a) diatomaceous earth (diatomite), uncalcined b) diatomaceous earth (diatomite), calcined c) synthetic amorphous silica (precipitated and gel) d) fused silica (quartz glass) - Wood dust - Flour dust - Dusts not classified according to toxicity - Organic dusts of animal and plant origin except wood and flour dust - Calcium sulphate (VI) (gypsum) - Carbon black - Coal (hard, brown) - Magnesium calcium carbonate (dolomite) - Silicon carbide, non-fibrous Range: (0,10 - 20,4) mg/m3 Gravimetric method PN-Z-04507:2022-05 PN-Z-04507:2022-05/Ap1:2022-08
17 工作场所环境 — 空气 Concentration of harmful dust agents – respirable fraction: - Apatites and phosphorites - Portland cement - Natural graphite - Amorphous and synthetic silica: a) diatomaceous earth (diatomite), uncalcined b) diatomaceous earth (diatomite), calcined c) synthetic amorphous silica (precipitated and gel) d) fused silica (quartz glass) - Organic dusts of animal and plant origin except wood and flour dust - Coal (hard, brown) Range: (0,11 - 7,3) mg/m3 Gravimetric method PN-Z-04508:2022-05 PN-Z-04508:2022-05/Ap1:2022-08
18 Workplace environment - air, - air samples collected on filters Concentration / content of iron oxides expressed as Fe - inhalable fraction Range: (0,043 - 12,9) mg/m3 (0,03 - 9,0) mg in the sample - respirable fraction Range: (0,045 - 13,4) mg/m3 (0,03 - 9,0) mg in the sample Flame atomic absorption spectrometry (FAAS) PN-Z-04469:2025-02
19 Workplace environment - air, - air samples collected on filters Concentration / content of manganese and its inorganic compounds expressed as Mn - inhalable fraction Range: (0,003 - 2,8) mg/m3 (0,002 - 2,0) mg in the sample - respirable fraction Range: (0,003 - 3,0) mg/m3 (0,002 - 2,0) mg in the sample Flame atomic absorption spectrometry (FAAS) PN-Z-04472:2015-10+Ap1:2015-12
20 Workplace environment - air, - air samples collected on filters Concentration / content of copper and its compounds expressed as Cu Range: (0,003 - 3,5) mg/m3 (0,002 - 2,5) mg in the sample Flame atomic absorption spectrometry (FAAS) PN-Z-04106-3:2002
21 Workplace environment - air, - air samples collected on filters Concentration / content of zinc oxide and its compounds expressed as Zn - inhalable fraction Range: (0,061 - 14,7) mg/m3 (0,03125 - 7,50) mg in the sample Flame atomic absorption spectrometry (FAAS) PN-87-Z-04100/03
22 Workplace environment - air, - air samples collected on filters Metallic nickel concentration/content Range: (0,004 - 3,5) mg/m3 (0,003 - 2,5) mg in the sample Flame atomic absorption spectrometry method (FAAS) PN-Z-04502:2019-10
23 Workplace environment - air, - air samples collected on filters Concentration/content of nickel compounds – calculated as Ni - inhalable fraction Range: (0,001 - 0,690) mg/m3 (0,001 - 0,500) mg in the sample - respirable fraction Range: (0,001 - 0,630) mg/m3 (0,001 - 0,500) mg in the sample Flame atomic absorption spectrometry method (FAAS) PN-Z-04502:2019-10
24 工作场所环境 — 空气 Gas concentration - Range: NO (0,16 - 7,50) mg/m3 (0,13 - 6,0) ppm NO2 (0,21 - 2,9) mg/m3 (0,11 - 1,5) ppm CO (1,40 - 140) mg/m3 (1,2 - 120) ppm Electrochemical method Procedura Badawcza QLB-03, wydanie 3 z dnia 24.11.2025 r.
25 Workplace environment - air, - air samples collected into absorbing solution Concentration / content of ammonia Range: (1,2 - 150) mg/m3 (0,012 - 1,5) mg in the sample Spectrophotometric method PN-71/Z-04041
26 Workplace environment - air, - air samples collected into absorbing solution Concentration / content of formaldehyde Range: (0,031 - 1,25) mg/m3 (0,000125 - 0,005) mg in the sample Spectrophotometric method PN-76/Z-04045/02
27 工作场所环境 — 空气 Concentration of organic compounds Range: acetone (0,63 - 3163) mg/m3 (0,00628 - 31,37) mg in the sample ethanol (0,65 - 6523) mg/m3 (0,00631 - 63,14) mg in the sample butan-1-ol (0,82 - 2059) mg/m3 (0,0081 - 20,24) mg in the sample 2-methylpropan-1-ol (0,66 - 1641) mg/m3 2-ethoxyethanol (0,79 - 158) mg/m3 (0,21 - 42,25) ppm (0,02325 - 4,65) mg in the sample 2-butoxyethanol (0,74 - 492) mg/m3 (0,0216 - 14,40) mg in the sample ethyl acetate (0,74 - 1849) mg/m3 (0,20 - 505,74) ppm (0,00720 - 18,00) mg in the sample n-butyl acetate (1,07 - 3577) mg/m3 (0,01056 - 35,20) mg in the sample 2-ethoxyethyl acetate (0,79 - 132) mg/m3 (0,14 - 24,07) ppm (0,02328 - 3,88) mg in the sample toluene (0,54 - 1350) mg/m3 (0,0052 - 13,00) mg in the sample xylene - mixture of isomers: 1,2; 1,3; 1,4; (0,53 - 1334) mg/m3 (0,00516 - 12,90) mg in the sample methanol (1,43 - 1906) mg/m3 (0,01426 - 19,00) mg in the sample Gas chromatography method with flame ionisation detection (GC-FID) Procedura Badawcza QLB-04, wydanie 3 z dnia 21.12.2018 r.
28 工作场所环境 — 空气 Concentration of organic compounds Range: propan-2-ol (0,81 - 8107) mg/m3 (0,00786 - 78,64) mg in the sample propan-1-ol (0,65 - 6510) mg/m3 (0,0064 - 64,00) mg in the sample pentane (0,64 - 6409) mg/m3 (0,00626 - 62,62) mg in the sample hexane (0,67 - 1345) mg/m3 (0,00655 - 13,09) mg in the sample heptane (0,70 - 3487) mg/m3 (0,0068 - 34,00) mg in the sample octane (0,57 - 7185) mg/m3 (0,00562 - 70,27) mg in the sample benzene (0,09 - 54) mg/m3 (0,03 - 16,66) ppm (0,00176 - 1,055) mg in the sample ethylbenzene (0,54 - 2707) mg/m3 (0,00522 - 26,10) mg in the sample styrene (0,56 - 1391) mg/m3 (0,00545 - 13,63) mg in the sample butan-2-one (0,65 - 6531) mg/m3 (0,00645 - 64,46) mg in the sample cyclohexanone (0,58 - 1167) mg/m3 (0,00569 - 11,37) mg in the sample tetrachloroethene (1,68 - 840) mg/m3 (0,24 - 122,06) ppm (0,0162 - 8,10) mg in the sample Gas chromatography method with flame ionisation detection (GC-FID) Procedura Badawcza QLB-04, wydanie 3 z dnia 21.12.2018 r.

引用标准 (18)

PN-71/Z-04041
PN-76/Z-04045/02
PN-87-Z-04100/03
PN-EN 14253+A1:2011
PN-EN ISO 11079:2008+Ap1:2013
PN-EN ISO 5349-1:2004 PN-EN ISO 5349-2:2004 PN-EN ISO 5349-2:2004/A1:2015-11
PN-EN ISO 7243:2018-01
PN-EN ISO 7730:2006 PN-EN ISO 7730:2006+Ap2:2016-04
PN-N-01307:1994 PN-EN ISO 9612:2011 z wyłączeniem metody obejmującej strategię 3 – punkt 11
PN-Z-04008-7:2002+Az1:2004
PN-Z-04106-3:2002
PN-Z-04469:2025-02
PN-Z-04472:2015-10+Ap1:2015-12
PN-Z-04502:2019-10
PN-Z-04507:2022-05 PN-Z-04507:2022-05/Ap1:2022-08
PN-Z-04508:2022-05 PN-Z-04508:2022-05/Ap1:2022-08
Procedura Badawcza QLB-03, wydanie 3 z dnia 24.11.2025 r.
Procedura Badawcza QLB-04, wydanie 3 z dnia 21.12.2018 r.