🇵🇱 AP Automatyka Maciej Pabel Marcin Prokopiak S.C. PL

PCA AP 234 • Poznań, Poland • 2 calibration items

Metrology & calibration

AP Automatyka Maciej Pabel Marcin Prokopiak S.C. is a calibration laboratory accredited by PCA under number AP 234 (Poznań, Poland). Its accreditation scope covers 2 calibration items in the following areas: Metrology & calibration. Calibrated items include: Electric thermometers (including electronic thermometers), Electrical thermometer (with data logger), Hygrometers, Temperature transmitters (including temperature sensors). Most frequently used calibration principles: Internal procedure; Direct method Calibration in a climatic chamber….

At a glance

  • Accreditation number: PCA AP 234
  • Calibration items in scope: 2
  • Types of calibrated items: 6
  • Calibration principles used: 1
  • City: Poznań, Poland
  • Valid until: 07-12-2029
Accreditation number
AP 234
Accreditation body
PCA
Address
ul. Masztowa 3, 61-345 Poznań
City
Poznań, Poland
Valid until
07-12-2029

What this laboratory calibrates (6)

Calibration principles (1)

Certificate information

Issue date
08.12.2025
Issue no.
1
Certificate date
08.12.2025
Accreditation cycle
08.12.2025 — 07.12.2029
Approved by
Tadeusz Matras

Accreditation scope — calibration items (2)

The uncertainty covered by the CMC is the expanded uncertainty with a coverage probability of approximately 95 % . The uncertainty covered by the CMC is expressed in measurand units.

No. Calibrated quantity / subject of calibration Nominal range / parameters / CMC Calibration principle Calibration procedure
Calibration items
1 Hygrometers
Transmitters
Thermohygrometers
Calibration — Relative humidity
temperature — 10 °C to 22 °C · CMC 0,1 °C relative humidity (block 10 °C to 22 °C) — 10 %rh to 38 %rh · CMC 0,9 %rh relative humidity (block 10 °C to 22 °C) — 39 %rh to 76 %rh · CMC 1,0 %rh relative humidity (block 10 °C to 22 °C) — 77 %rh to 95 %rh · CMC 1,1 %rh temperature — 22 °C to 80 °C · CMC 0,1 °C relative humidity (block 22 °C to 80 °C) — 10 %rh to 29 %rh · CMC 0,9 %rh relative humidity (block 22 °C to 80 °C) — 30 %rh to 73 %rh · CMC 1,0 %rh relative humidity (block 22 °C to 80 °C) — 74 %rh to 95 %rh · CMC 1,1 %rh
Relative humidity
Internal procedure; Direct method Calibration in a climatic chamber; At permanent location (S) 1.2.4/1
2 Temperature transmitters (including temperature sensors)
Electric thermometers (including electronic thermometers)
Electrical thermometer (with data logger)
Calibration — Temperature (electric thermometry)
-40 °C to 90 °C · CMC 0,1 °C
Temperature (electric thermometry)
Internal procedure; Direct method Calibration in a climatic chamber; At permanent location (S) 1.2.4/1

Reference standards (1)

1.2.4/1

The same scope as data (JSON): https://labcoda.pl/api/accreditation-scopes/labs/PL/AP%20234