🇵🇱 Zdzisław Bogusławski Przedsiębiorstwo Handlowo-Usługowo Produkcyjne MERASERW-9 PL
Metrology & calibration
Zdzisław Bogusławski Przedsiębiorstwo Handlowo-Usługowo Produkcyjne MERASERW-9 is a calibration laboratory accredited by PCA under number AP 228 (Wrocław, Poland). Its accreditation scope covers 8 calibration items in the following areas: Metrology & calibration. Calibrated items include: - resolution 0,01 mm, Calipers, Digital indicators, External micrometers. Most frequently used calibration principles: At permanent location (S), Internal procedure; At permanent location (S).
At a glance
- Accreditation number: PCA AP 228
- Calibration items in scope: 8
- Types of calibrated items: 9
- Calibration principles used: 2
- City: Wrocław, Poland
- Valid until: 27-04-2029
- Accreditation number
- AP 228
- Accreditation body
- PCA
- Address
- pl. Strzelecki 20, 50-224 Wrocław
- City
- Wrocław, Poland
- Division
- Zdzisław Bogusławski Przedsiębiorstwo Handlowo-Usługowo Produkcyjne "MERASERW-9"
- Valid until
- 27-04-2029
What this laboratory calibrates (9)
- - resolution 0,01 mm — 1 calibration item
- Calipers — 1 calibration item
- Digital indicators — 1 calibration item
- External micrometers — 1 calibration item
- Feeler gauges — 1 calibration item
- Internal micrometers — 1 calibration item
- Micrometer depth gauges — 1 calibration item
- Vernier depth gauges — 1 calibration item
- Vernier height gauges — 1 calibration item
Calibration principles (2)
- At permanent location (S) — 5 calibration items
- Internal procedure; At permanent location (S) — 3 calibration items
Certificate information
- Issue date
- 28.04.2025
- Issue no.
- 1
- Certificate date
- 28.04.2025
- Accreditation cycle
- 28.04.2025 — 27.04.2029
- Approved by
- Tadeusz Matras
Accreditation scope — calibration items (8)
| No. | Calibrated quantity / subject of calibration | Nominal range / parameters / CMC | Calibration principle | Calibration procedure | |
|---|---|---|---|---|---|
| Calibration items | |||||
| 1 | Digital indicators - resolution 0,01 mm |
Calibration — Length 0 mm to 30 mm · CMC 7 µm Length |
At permanent location (S) | PN-EN ISO 13102:2013 | |
| 2 | Micrometer depth gauges | Calibration — Length 0 mm to 50 mm · CMC 2,1 µm 50 mm do 100 mm · CMC 3,2 µm 100 mm do 150 mm · CMC 4,7 µm 150 mm do 200 mm · CMC 5,9 µm 200 mm do 250 mm · CMC 7,3 µm 250 mm do 300 mm · CMC 8,7 µm Length |
Internal procedure; At permanent location (S) | PT05 | |
| 3 | Vernier depth gauges | Calibration — Length 0 mm to 150 mm · CMC 9 µm 0 mm to 300 mm · CMC 12 µm Length |
At permanent location (S) | PN-EN ISO 13385-2:2020 | |
| 4 | Internal micrometers | Calibration — Length 5 mm to 100 mm · CMC 3,2 µm Length |
Internal procedure; At permanent location (S) | PT05 | |
| 5 | External micrometers | Calibration — Length 0 mm to 50 mm · CMC 2,0 µm 50 mm do 100 mm · CMC 3,2 µm 100 mm do 150 mm · CMC 4,7 µm 150 mm do 200 mm · CMC 5,9 µm 200 mm do 250 mm · CMC 7,3 µm 250 mm do 300 mm · CMC 8,7 µm Length |
At permanent location (S) | PN-EN ISO 3611:2023 | |
| 6 | Calipers | Calibration — Length 0 mm do 150 mm · CMC 9 µm 0 mm do 300 mm · CMC 12 µm 0 mm do 500 mm · CMC 17 µm 0 mm to 1000 mm · CMC 30 µm Length |
At permanent location (S) | PN-EN ISO 13385-1:2019 | |
| 7 | Feeler gauges | Calibration — Length 0,02 mm to 2 mm · CMC 4 µm Length |
Internal procedure; At permanent location (S) | PT07 | |
| 8 | Vernier height gauges | Calibration — Length 0 mm do 300 mm · CMC 12 µm 0 mm to 600 mm · CMC 19 µm 0 mm to 1000 mm · CMC 30 µm Length |
At permanent location (S) | PN-EN ISO 13225:2012 | |
Reference standards (7)
PN-EN ISO 13102:2013
PN-EN ISO 13225:2012
PN-EN ISO 13385-1:2019
PN-EN ISO 13385-2:2020
PN-EN ISO 3611:2023
PT05
PT07