Metrology & calibration
CALMET sp. z o.o. is a calibration laboratory accredited by PCA under number AP 216 (Zielona Góra, Poland). Its accreditation scope covers 16 calibration items in the following areas: Metrology & calibration. Calibrated items include: Calibrators, Power network parameter meters, Clamp meters, Multimeters. Most frequently used calibration principles: Internal procedure; Direct method; At permanent location (S).
At a glance
- Accreditation number: PCA AP 216
- Calibration items in scope: 16
- Types of calibrated items: 11
- Calibration principles used: 1
- City: Zielona Góra, Poland
- Valid until: 16-01-2027
- Accreditation number
- AP 216
- Accreditation body
- PCA
- Address
- ul. Kukułcza 18, 65-472 Zielona Góra
- City
- Zielona Góra, Poland
- Division
- Calmet Calibration Laboratory
- Valid until
- 16-01-2027
What this laboratory calibrates (11)
- Calibrators — 6 calibration items
- Power network parameter meters — 6 calibration items
- Clamp meters — 4 calibration items
- Multimeters — 3 calibration items
- Alternating current electrical energy meters — 1 calibration item
- Digital ammeters — 1 calibration item
- Digital frequency meters — 1 calibration item
- Digital power meters — 1 calibration item
- Digital voltmeters — 1 calibration item
- Electrical energy meter test equipment — 1 calibration item
- Phase meters — 1 calibration item
Calibration principles (1)
- Internal procedure; Direct method; At permanent location (S) — 16 calibration items
Certificate information
- Issue date
- 03.01.2025
- Issue no.
- 2
- Certificate date
- 17.01.2023
- Accreditation cycle
- 17.01.2023 — 16.01.2027
- Approved by
- Katarzyna Wiśniewska
Accreditation scope — calibration items (16)
| No. | Calibrated quantity / subject of calibration | Nominal range / parameters / CMC | Calibration principle | Calibration procedure | |
|---|---|---|---|---|---|
| Calibration items | |||||
| 1 | Power network parameter meters Digital voltmeters Multimeters |
Calibration — AC voltage 45 Hz to 65 Hz; 10 V to 30 V · CMC 0,015 % 45 Hz to 65 Hz; 30 V to 525 V · CMC 0,006 % AC voltage |
Internal procedure; Direct method; At permanent location (S) | PW-01 based on EURAMET cg-15 v. 3.0 | |
| 2 | Calibrators | Calibration — AC voltage 45 Hz to 65 Hz; 10 V to 30 V · CMC 0,015 % 45 Hz to 65 Hz; 30 V to 525 V · CMC 0,006 % AC voltage |
Internal procedure; Direct method; At permanent location (S) | PW-02 | |
| 3 | Power network parameter meters Digital ammeters Multimeters |
Calibration — AC current 45 Hz to 65 Hz; 0,01 A to 0,25 A · CMC 0,01 % 45 Hz to 65 Hz; 0,25 A to 120 A · CMC 0,007 % AC current |
Internal procedure; Direct method; At permanent location (S) | PW-01 based on EURAMET cg-15 v 3.0 | |
| 4 | Clamp meters | Calibration — AC current 45 Hz to 65 Hz; 0,25 A to 120 A · CMC 0,05 % AC current |
Internal procedure; Direct method; At permanent location (S) | PW-01 | |
| 5 | Calibrators | Calibration — AC current 45 Hz to 65 Hz; 0,01 A to 0,25 A · CMC 0,01 % 45 Hz to 65 Hz; 0,25 A to 120 A · CMC 0,007 % AC current |
Internal procedure; Direct method; At permanent location (S) | PW-02 | |
| 6 | Power network parameter meters Phase meters |
Calibration — Phase angle 45 Hz to 65 Hz; 30 V to 525 V; 0,25 A to 120 A; 0° to 360° · CMC 0,005° Phase angle |
Internal procedure; Direct method; At permanent location (S) | PW-01 | |
| 7 | Clamp meters | Calibration — Phase angle 45 Hz to 65 Hz; 30 V to 525 V; 0,25 A to 120 A; 0° to 360° · CMC 0,04° Phase angle |
Internal procedure; Direct method; At permanent location (S) | PW-01 | |
| 8 | Calibrators | Calibration — Phase angle 45 Hz to 65 Hz; 30 V to 525 V; 0,25 A to 120 A; 0° to 360° · CMC 0,005° Phase angle |
Internal procedure; Direct method; At permanent location (S) | PW-02 | |
| 9 | Power network parameter meters Alternating current electrical energy meters Electrical energy meter test equipment |
Calibration — Energy 45 Hz to 65 Hz; 30 V to 525 V; 0° to 360°; cosφ or sinφ: 0,5 to 1; 0,01 A to 0,25 A · CMC 0,015 % 45 Hz to 65 Hz; 30 V to 525 V; 0° to 360°; cosφ or sinφ: 0,5 to 1; 0,25 A to 120 A · CMC 0,007 % Energy |
Internal procedure; Direct method; At permanent location (S) | PW-01 | |
| 10 | Clamp meters | Calibration — Energy 45 Hz to 65 Hz; 30 V to 525 V; 0° to 360°; cosφ or sinφ: 0,5 to 1; 0,25 A to 120 A · CMC 0,05 % Energy |
Internal procedure; Direct method; At permanent location (S) | PW-01 | |
| 11 | Calibrators | Calibration — Energy 45 Hz to 65 Hz; 30 V to 525 V; 0° to 360°; cosφ or sinφ: 0,5 to 1; 0,01 A to 0,25 A · CMC 0,015 % 45 Hz to 65 Hz; 30 V to 525 V; 0° to 360°; cosφ or sinφ: 0,5 to 1; 0,25 A to 120 A · CMC 0,007 % Energy |
Internal procedure; Direct method; At permanent location (S) | PW-02 | |
| 12 | Power network parameter meters Digital power meters |
Calibration — AC power 0,15 W to 189 kW; 0,15 var to 189 kvar; 0,3 VA to 189 kVA; 45 Hz to 65 Hz; 30 V to 525 V; 0° to 360°; cosφ or sinφ: 0,5 to 1; 0,01 A to 0,25 A · CMC 0,015 % 0,15 W to 189 kW; 0,15 var to 189 kvar; 0,3 VA to 189 kVA; 45 Hz to 65 Hz; 30 V to 525 V; 0° to 360°; cosφ or sinφ: 0,5 to 1; 0,25 A to 120 A · CMC 0,007 % AC power |
Internal procedure; Direct method; At permanent location (S) | PW-01 | |
| 13 | Clamp meters | Calibration — AC power 3,75 W to 189 kW; 3,75 var to 189 kvar; 7,5 VA to 189 kVA; 45 Hz to 65 Hz; 30 V to 525 V; 0° to 360°; cosφ or sinφ: 0,5 to 1; 0,25 A to 120 A · CMC 0,05 % AC power |
Internal procedure; Direct method; At permanent location (S) | PW-01 | |
| 14 | Calibrators | Calibration — AC power 0,15 W to 189 kW; 0,15 var to 189 kvar; 0,3 VA to 189 kVA; 45 Hz to 65 Hz; 30 V to 525 V; 0° to 360°; cosφ or sinφ: 0,5 to 1; 0,01 A to 0,25 A · CMC 0,015 % 0,15 W to 189 kW; 0,15 var to 189 kvar; 0,3 VA to 189 kVA; 45 Hz to 65 Hz; 30 V to 525 V; 0° to 360°; cosφ or sinφ: 0,5 to 1; 0,25 A to 120 A · CMC 0,007 % AC power |
Internal procedure; Direct method; At permanent location (S) | PW-02 | |
| 15 | Power network parameter meters Multimeters Digital frequency meters |
Calibration — Frequency 45 Hz to 65 Hz · CMC 0,0003 % Frequency |
Internal procedure; Direct method; At permanent location (S) | PW-01 | |
| 16 | Calibrators | Calibration — Frequency 45 Hz to 65 Hz · CMC 0,0003 % Frequency |
Internal procedure; Direct method; At permanent location (S) | PW-02 | |
Reference standards (4)
EURAMET cg-15 v 3.0
EURAMET cg-15 v. 3.0
PW-01
PW-02