🇵🇱 CALMET sp. z o.o. PL

PCA AP 216 • Zielona Góra, Poland • 16 calibration items

Metrology & calibration

CALMET sp. z o.o. is a calibration laboratory accredited by PCA under number AP 216 (Zielona Góra, Poland). Its accreditation scope covers 16 calibration items in the following areas: Metrology & calibration. Calibrated items include: Calibrators, Power network parameter meters, Clamp meters, Multimeters. Most frequently used calibration principles: Internal procedure; Direct method; At permanent location (S).

At a glance

  • Accreditation number: PCA AP 216
  • Calibration items in scope: 16
  • Types of calibrated items: 11
  • Calibration principles used: 1
  • City: Zielona Góra, Poland
  • Valid until: 16-01-2027
Accreditation number
AP 216
Accreditation body
PCA
Address
ul. Kukułcza 18, 65-472 Zielona Góra
City
Zielona Góra, Poland
Division
Calmet Calibration Laboratory
Valid until
16-01-2027

What this laboratory calibrates (11)

Calibration principles (1)

Certificate information

Issue date
03.01.2025
Issue no.
2
Certificate date
17.01.2023
Accreditation cycle
17.01.2023 — 16.01.2027
Approved by
Katarzyna Wiśniewska

Accreditation scope — calibration items (16)

The uncertainty covered by the CMC is the expanded uncertainty with a coverage probability of approximately 95 %. A value expressed as a percentage is the relative measurement uncertainty and refers to the percentage of the value of the measurand. In other cases the CMC uncertainty is expressed in measurand units.

No. Calibrated quantity / subject of calibration Nominal range / parameters / CMC Calibration principle Calibration procedure
Calibration items
1 Power network parameter meters
Digital voltmeters
Multimeters
Calibration — AC voltage
45 Hz to 65 Hz; 10 V to 30 V · CMC 0,015 % 45 Hz to 65 Hz; 30 V to 525 V · CMC 0,006 %
AC voltage
Internal procedure; Direct method; At permanent location (S) PW-01 based on EURAMET cg-15 v. 3.0
2 Calibrators Calibration — AC voltage
45 Hz to 65 Hz; 10 V to 30 V · CMC 0,015 % 45 Hz to 65 Hz; 30 V to 525 V · CMC 0,006 %
AC voltage
Internal procedure; Direct method; At permanent location (S) PW-02
3 Power network parameter meters
Digital ammeters
Multimeters
Calibration — AC current
45 Hz to 65 Hz; 0,01 A to 0,25 A · CMC 0,01 % 45 Hz to 65 Hz; 0,25 A to 120 A · CMC 0,007 %
AC current
Internal procedure; Direct method; At permanent location (S) PW-01 based on EURAMET cg-15 v 3.0
4 Clamp meters Calibration — AC current
45 Hz to 65 Hz; 0,25 A to 120 A · CMC 0,05 %
AC current
Internal procedure; Direct method; At permanent location (S) PW-01
5 Calibrators Calibration — AC current
45 Hz to 65 Hz; 0,01 A to 0,25 A · CMC 0,01 % 45 Hz to 65 Hz; 0,25 A to 120 A · CMC 0,007 %
AC current
Internal procedure; Direct method; At permanent location (S) PW-02
6 Power network parameter meters
Phase meters
Calibration — Phase angle
45 Hz to 65 Hz; 30 V to 525 V; 0,25 A to 120 A; 0° to 360° · CMC 0,005°
Phase angle
Internal procedure; Direct method; At permanent location (S) PW-01
7 Clamp meters Calibration — Phase angle
45 Hz to 65 Hz; 30 V to 525 V; 0,25 A to 120 A; 0° to 360° · CMC 0,04°
Phase angle
Internal procedure; Direct method; At permanent location (S) PW-01
8 Calibrators Calibration — Phase angle
45 Hz to 65 Hz; 30 V to 525 V; 0,25 A to 120 A; 0° to 360° · CMC 0,005°
Phase angle
Internal procedure; Direct method; At permanent location (S) PW-02
9 Power network parameter meters
Alternating current electrical energy meters
Electrical energy meter test equipment
Calibration — Energy
45 Hz to 65 Hz; 30 V to 525 V; 0° to 360°; cosφ or sinφ: 0,5 to 1; 0,01 A to 0,25 A · CMC 0,015 % 45 Hz to 65 Hz; 30 V to 525 V; 0° to 360°; cosφ or sinφ: 0,5 to 1; 0,25 A to 120 A · CMC 0,007 %
Energy
Internal procedure; Direct method; At permanent location (S) PW-01
10 Clamp meters Calibration — Energy
45 Hz to 65 Hz; 30 V to 525 V; 0° to 360°; cosφ or sinφ: 0,5 to 1; 0,25 A to 120 A · CMC 0,05 %
Energy
Internal procedure; Direct method; At permanent location (S) PW-01
11 Calibrators Calibration — Energy
45 Hz to 65 Hz; 30 V to 525 V; 0° to 360°; cosφ or sinφ: 0,5 to 1; 0,01 A to 0,25 A · CMC 0,015 % 45 Hz to 65 Hz; 30 V to 525 V; 0° to 360°; cosφ or sinφ: 0,5 to 1; 0,25 A to 120 A · CMC 0,007 %
Energy
Internal procedure; Direct method; At permanent location (S) PW-02
12 Power network parameter meters
Digital power meters
Calibration — AC power
0,15 W to 189 kW; 0,15 var to 189 kvar; 0,3 VA to 189 kVA; 45 Hz to 65 Hz; 30 V to 525 V; 0° to 360°; cosφ or sinφ: 0,5 to 1; 0,01 A to 0,25 A · CMC 0,015 % 0,15 W to 189 kW; 0,15 var to 189 kvar; 0,3 VA to 189 kVA; 45 Hz to 65 Hz; 30 V to 525 V; 0° to 360°; cosφ or sinφ: 0,5 to 1; 0,25 A to 120 A · CMC 0,007 %
AC power
Internal procedure; Direct method; At permanent location (S) PW-01
13 Clamp meters Calibration — AC power
3,75 W to 189 kW; 3,75 var to 189 kvar; 7,5 VA to 189 kVA; 45 Hz to 65 Hz; 30 V to 525 V; 0° to 360°; cosφ or sinφ: 0,5 to 1; 0,25 A to 120 A · CMC 0,05 %
AC power
Internal procedure; Direct method; At permanent location (S) PW-01
14 Calibrators Calibration — AC power
0,15 W to 189 kW; 0,15 var to 189 kvar; 0,3 VA to 189 kVA; 45 Hz to 65 Hz; 30 V to 525 V; 0° to 360°; cosφ or sinφ: 0,5 to 1; 0,01 A to 0,25 A · CMC 0,015 % 0,15 W to 189 kW; 0,15 var to 189 kvar; 0,3 VA to 189 kVA; 45 Hz to 65 Hz; 30 V to 525 V; 0° to 360°; cosφ or sinφ: 0,5 to 1; 0,25 A to 120 A · CMC 0,007 %
AC power
Internal procedure; Direct method; At permanent location (S) PW-02
15 Power network parameter meters
Multimeters
Digital frequency meters
Calibration — Frequency
45 Hz to 65 Hz · CMC 0,0003 %
Frequency
Internal procedure; Direct method; At permanent location (S) PW-01
16 Calibrators Calibration — Frequency
45 Hz to 65 Hz · CMC 0,0003 %
Frequency
Internal procedure; Direct method; At permanent location (S) PW-02

Reference standards (4)

EURAMET cg-15 v 3.0
EURAMET cg-15 v. 3.0
PW-01
PW-02

The same scope as data (JSON): https://labcoda.pl/api/accreditation-scopes/labs/PL/AP%20216