🇵🇱 Merserwis Spółka z ograniczoną odpowiedzialnością Sp. K. PL

PCA AP 215 • Warszawa, Poland • 65 calibration items

Metrology & calibration

Merserwis Spółka z ograniczoną odpowiedzialnością Sp. K. is a calibration laboratory accredited by PCA under number AP 215 (Warszawa, Poland). Its accreditation scope covers 65 calibration items in the following areas: Metrology & calibration. Calibrated items include: Power quality meters, Multimeters, Power network parameter meters, Calibrators. Most frequently used calibration principles: Internal procedure; Direct method; At permanent location (S), Internal procedure; Direct method; Outside of permanent location (P), Internal procedure; Direct method; At permanent location (S) and ou….

At a glance

  • Accreditation number: PCA AP 215
  • Calibration items in scope: 65
  • Types of calibrated items: 47
  • Calibration principles used: 17
  • City: Warszawa, Poland
  • Valid until: 03-01-2027
Accreditation number
AP 215
Accreditation body
PCA
Address
ul. Gen. Wł. Andersa 10, 00-201 Warszawa
City
Warszawa, Poland
Valid until
03-01-2027

What this laboratory calibrates (47)

Calibration principles (17)

Certificate information

Issue date
17.04.2026
Issue no.
5
Certificate date
04.01.2023
Accreditation cycle
04.01.2023 — 03.01.2027
Approved by
Katarzyna Wiśniewska

Accreditation scope — calibration items (65)

The uncertainty covered by the CMC is the expanded uncertainty with a coverage probability of approximately 95 % and is expressed in measurand units. A CMC uncertainty value expressed as a percentage is the relative measurement uncertainty and refers to the percentage of the value of the measurand.

No. Calibrated quantity / subject of calibration Nominal range / parameters / CMC Calibration principle Calibration procedure
Calibration items
1 Digital voltmeters
Multimeters
Power quality meters
Clamp meters
Scopemeters (DMM)
Calibration — DC voltage
0,1 mV to 200 mV · CMC 5 · 10⁻⁶ · U + 0,3 µV 0,2 V to 20 V · CMC 0,0004 % 20 V to 200 V · CMC 0,0005 % 200 V to 1000 V · CMC 5 · 10⁻⁶ · U + 0,5 mV
DC voltage
Internal procedure; Indirect / direct method; At permanent location (S) Internal procedure OP-W-01 based on EURAMET cg-15 v. 3
2 Calibrators
Reference sources
Power supplies
Calibration — DC voltage
0,1 mV to 200 mV · CMC 5 · 10⁻⁶ · U + 0,3 µV 0,2 V to 20 V · CMC 0,0004 % 20 V to 200 V · CMC 0,0005 % 200 V to 1000 V · CMC 5 · 10⁻⁶ · U + 0,5 mV
DC voltage
Internal procedure; Direct method; At permanent location (S) Internal procedure OP-W-03
3 Digital voltmeters
Multimeters
Power quality meters
Clamp meters
Scopemeters (DMM)
Calibration — DC voltage
0,1 mV to 200 mV · CMC 5 · 10⁻⁶ · U + 6 µV 0,2 V to 2 V · CMC 1 · 10⁻⁵ · U + 30 µV 2 V to 20 V · CMC 3 · 10⁻⁵ · U + 0,5 mV 20 V to 200 V · CMC 4 · 10⁻⁵ · U + 2 mV 200 V to 1000 V · CMC 0,005 %
DC voltage
Internal procedure; Indirect / direct method; Outside of permanent location (P) Internal procedure OP-W-01 based on EURAMET cg-15 v. 3
4 Calibrators
Reference sources
Power supplies
Calibration — DC voltage
0,1 mV to 200 mV · CMC 5 · 10⁻⁶ · U + 6 µV 0,2 V to 2 V · CMC 1 · 10⁻⁵ · U + 30 µV 2 V to 20 V · CMC 3 · 10⁻⁵ · U + 0,5 mV 20 V to 200 V · CMC 4 · 10⁻⁵ · U + 2 mV 200 V to 1000 V · CMC 0,005 %
DC voltage
Internal procedure; Direct method; Outside of permanent location (P) Internal procedure OP-W-03
5 Oscilloscopes
Scopemeters
Calibration — DC voltage
1 mV to 280 V · CMC 5 ∙ 10⁻⁴ ∙ U + 60 µV
DC voltage
Internal procedure; Direct method; At permanent location (S) Internal procedure OP-W-08 based on EURAMET cg-7 v. 2.0
6 Breakdown testers
Electrical safety testers
Calibration — DC voltage
50 V to 1000 V · CMC 1,5 ∙ 10⁻⁴ ∙ U + 0,5 V
DC voltage
Internal procedure; At permanent location (S) and outside of it (P) Internal procedure OP-W-03
7 Digital ammeters
Multimeters
Power quality meters
Scopemeters (DMM)
Calibration — DC current
1 µA to 200 µA · CMC 5 · 10⁻⁵ · I + 6 nA 0,2 mA to 20 mA · CMC 3,5 · 10⁻⁵ · I + 0,1 µA 20 mA to 200 mA · CMC 5 · 10⁻⁵ · I + 1 µA 0,2 A to 2 A · CMC 0,025 % 2 A to 10 A · CMC 3 · 10⁻⁴ · I + 0,1 mA 10 A to 20 A · CMC 0,03 % 20 A to 38 A · CMC 3 · 10⁻⁴ · I + 15 mA
DC current
Internal procedure; Direct and indirect method; At permanent location (S) Internal procedure OP-W-01 based on EURAMET cg-15 v. 3
8 Clamp meters Calibration — DC current
1 mA to 1 A · CMC 0,016 % 1 A to 10 A · CMC 0,04 % 10 A to 1000 A · CMC 0,33 %
DC current
Internal procedure; Direct method; At permanent location (S) Internal procedure OP-W-01
9 Calibrators
DC current sources
Power supplies
Calibration — DC current
1 µA to 200 µA · CMC 2 · 10⁻⁵ · I + 0,5 nA 0,2 mA to 20 mA · CMC 2 · 10⁻⁵ · I + 10 nA 20 mA to 200 mA · CMC 4 · 10⁻⁵ · I + 2 µA 0,2 A to 2 A · CMC 0,02 % 2 A to 20 A · CMC 0,03 % 20 A to 30 A · CMC 0,02 % 30 A to 200 A · CMC 2 · 10⁻⁴ · I + 0,02 A
DC current
Internal procedure; Direct method; At permanent location (S) Internal procedure OP-W-03
10 Digital ammeters
Multimeters
Power quality meters
Scopemeters (DMM)
Calibration — DC current
1 µA to 100 µA · CMC 5 · 10⁻⁴ · I + 30 nA 0,1 mA to 100 mA · CMC 5 · 10⁻⁴ · I + 0,1 µA 0,1 A to 1 A · CMC 2 · 10⁻⁴ · I + 0,5 mA 1 A to 2 A · CMC 0,03 % 2 A to 10 A · CMC 0,1 % 10 A to 20 A · CMC 0,04 %
DC current
Internal procedure; Direct method; Outside of permanent location (P) Internal procedure OP-W-01 based on EURAMET cg-15 v. 3
11 Clamp meters Calibration — DC current
1 mA to 1 A · CMC 0,03 % 1 A to 10 A · CMC 0,12 % 10 A to 1000 A · CMC 0,4 %
DC current
Internal procedure; Direct method; Outside of permanent location (P) Internal procedure OP-W-01
12 Calibrators
DC current sources
Power supply
Calibration — DC current
1 µA to 100 µA · CMC 1 · 10⁻⁴ · I + 1 nA 0,1 mA to 10 mA · CMC 1 · 10⁻⁴ · I + 0,1 µA 10 mA to 100 mA · CMC 2 · 10⁻⁴ · I + 5 µA 0,1 A to 1 A · CMC 5 · 10⁻⁴ · I + 0,1 mA 1 A to 3 A · CMC 5 · 10⁻⁴ · I + 0,1 mA 3 A to 30 A · CMC 3 · 10⁻⁴ · I + 0,001 mA 30 A to 200 A · CMC 2 · 10⁻⁴ · I + 0,02 A
DC current
Internal procedure; Direct method; Outside of permanent location (P) Internal procedure OP-W-03
13 Digital voltmeters
Multimeters
Power quality meters
Clamp meters
Residual current device testers
Scopemeters (DMM)
Calibration — AC voltage
10 Hz to 2 kHz — 1 mV to 10 mV · CMC 2 · 10⁻⁴ · U + 2 µV 10 Hz to 2 kHz — 10 mV to 100 mV · CMC 7 · 10⁻⁵ · U + 1 µV 10 Hz to 2 kHz — 0,1 V to 1 V · CMC 8 · 10⁻⁵·U + 5 µV 10 Hz to 2 kHz — 1 V to 10 V · CMC 8 · 10⁻⁵ · U + 50 µV 10 Hz to 2 kHz — 10 V to 100 V · CMC 8 · 10⁻⁵ · U + 0,5 mV 10 Hz to 2 kHz — 100 V to 1000 V · CMC 1 · 10⁻⁴ · U + 0,03 V 2 kHz to 10 kHz — 1 mV to 10 mV · CMC 3 · 10⁻⁴ · U + 2 µV 2 kHz to 10 kHz — 10 mV to 100 mV · CMC 1,2 · 10⁻⁴ · U + 1 µV 2 kHz to 10 kHz — 0,1 V to 100 V · CMC 0,015 % 2 kHz to 10 kHz — 100 V to 1000 V · CMC 1 · 10⁻⁴ · U + 0,03 V 10 kHz to 30 kHz — 1 mV to 10 mV · CMC 3·10⁻⁴·U + 2 µV 10 kHz to 30 kHz — 10 mV to 100 mV · CMC 2,2 · 10⁻⁴ · U + 1 µV 10 kHz to 30 kHz — 0,1 V to 100 V · CMC 0,03 % 10 kHz to 30 kHz — 100 V to 1000 V · CMC 0,035 % 30 kHz to 100 kHz — 1 mV to 10 mV · CMC 3,5 · 10⁻³ · U + 2 µV 30 kHz to 100 kHz — 10 mV to 100 mV · CMC 8 · 10⁻⁴ · U + 1 µV 30 kHz to 100 kHz — 0,1 V to 100 V · CMC 0,08 % 30 kHz to 100 kHz — 100 V to 1000 V · CMC 0,12 % 100 kHz to 300 kHz — 1 mV to 10 mV · CMC 1,5 % 100 kHz to 300 kHz — 10 mV to 10 V · CMC 0,5 % 100 kHz to 300 kHz — 10 V to 100 V · CMC 0,8 % 300 kHz to 1 MHz — 10 mV to 1 V · CMC 1,5 · 10⁻² · U + 0,5 mV 300 kHz to 1 MHz — 1 V to 10 V · CMC 1,5 · 10⁻² · U + 5 mV 300 kHz to 1 MHz — 10 V to 100 V · CMC 3,5 · 10⁻² · U + 10 mV
AC voltage
Internal procedure; Indirect / direct method; At permanent location (S) Internal procedure OP-W-01 based on EURAMET cg-15 v. 3
14 Calibrators
Power supplies
Calibration — AC voltage
10 Hz to 2 kHz — 1 mV to 10 mV · CMC 2 · 10⁻⁴ · U + 2 µV 10 Hz to 2 kHz — 10 mV to 100 mV · CMC 7 · 10⁻⁵ · U + 1 µV 10 Hz to 2 kHz — 0,1 V to 1 V · CMC 8 · 10⁻⁵·U + 5 µV 10 Hz to 2 kHz — 1 V to 10 V · CMC 8 · 10⁻⁵ · U + 50 µV 10 Hz to 2 kHz — 10 V to 100 V · CMC 8 · 10⁻⁵ · U + 0,5 mV 10 Hz to 2 kHz — 100 V to 1000 V · CMC 1 · 10⁻⁴ · U + 0,03 V 2 kHz to 10 kHz — 1 mV to 10 mV · CMC 3 · 10⁻⁴ · U + 2 µV 2 kHz to 10 kHz — 10 mV to 100 mV · CMC 1,2 · 10⁻⁴ · U + 1 µV 2 kHz to 10 kHz — 0,1 V to 100 V · CMC 0,015 % 2 kHz to 10 kHz — 100 V to 1000 V · CMC 1 · 10⁻⁴ · U + 0,03 V 10 kHz to 30 kHz — 1 mV to 10 mV · CMC 3·10⁻⁴·U + 2 µV 10 kHz to 30 kHz — 10 mV to 100 mV · CMC 2,2 · 10⁻⁴ · U + 1 µV 10 kHz to 30 kHz — 0,1 V to 100 V · CMC 0,03 % 10 kHz to 30 kHz — 100 V to 1000 V · CMC 0,035 % 30 kHz to 100 kHz — 1 mV to 10 mV · CMC 3,5 · 10⁻³ · U + 2 µV 30 kHz to 100 kHz — 10 mV to 100 mV · CMC 8 · 10⁻⁴ · U + 1 µV 30 kHz to 100 kHz — 0,1 V to 100 V · CMC 0,08 % 30 kHz to 100 kHz — 100 V to 1000 V · CMC 0,12 % 100 kHz to 300 kHz — 1 mV to 10 mV · CMC 1,5 % 100 kHz to 300 kHz — 10 mV to 10 V · CMC 0,5 % 100 kHz to 300 kHz — 10 V to 100 V · CMC 0,8 % 300 kHz to 1 MHz — 10 mV to 1 V · CMC 1,5 · 10⁻² · U + 0,5 mV 300 kHz to 1 MHz — 1 V to 10 V · CMC 1,5 · 10⁻² · U + 5 mV 300 kHz to 1 MHz — 10 V to 100 V · CMC 3,5 · 10⁻² · U + 10 mV
AC voltage
Internal procedure; Direct method; At permanent location (S) Internal procedure OP-W-03
15 Digital voltmeters
Multimeters
Power quality meters
Clamp meters
Residual current device testers
Scopemeters (DMM)
Calibration — AC voltage
10 Hz to 20 kHz — 1 mV to 100 mV · CMC 6 · 10⁻⁴ · U + 50 µV 10 Hz to 20 kHz — 0,1 V to 1 V · CMC 6 · 10⁻⁴ · U + 0,5 mV 10 Hz to 20 kHz — 1 V to 10 V · CMC 6 · 10⁻⁴ · U + 5 mV 10 Hz to 20 kHz — 10 V to 100 V · CMC 6 · 10⁻⁴ · U + 50 mV 10 Hz to 20 kHz — 100 V to 700 V · CMC 6 · 10⁻⁴ · U + 0,3 V 20 kHz to 50 kHz — 1 mV to 10 mV · CMC 6 · 10⁻⁴ · U + 60 µV 20 kHz to 50 kHz — 10 mV to 100 mV · CMC 1,4 · 10⁻³ · U + 55 µV 20 kHz to 50 kHz — 0,1 V to 1 V · CMC 2 · 10⁻³ · U + 0,55 mV 20 kHz to 50 kHz — 1 V to 10 V · CMC 2 · 10⁻³ · U + 5 mV 20 kHz to 50 kHz — 10 V to 100 V · CMC 2 · 10⁻³ · U + 50 mV 20 kHz to 50 kHz — 100 V to 700 V · CMC 2 · 10⁻³ · U + 0,3 V
AC voltage
Internal procedure; Indirect / direct method; Outside of permanent location (P) Internal procedure OP-W-01 based on EURAMET cg-15 v. 3
16 Calibrators
Power supplies
Calibration — AC voltage
10 Hz to 20 kHz — 1 mV to 100 mV · CMC 6 · 10⁻⁴ · U + 50 µV 10 Hz to 20 kHz — 0,1 V to 1 V · CMC 6 · 10⁻⁴ · U + 0,5 mV 10 Hz to 20 kHz — 1 V to 10 V · CMC 6 · 10⁻⁴ · U + 5 mV 10 Hz to 20 kHz — 10 V to 100 V · CMC 6 · 10⁻⁴ · U + 50 mV 10 Hz to 20 kHz — 100 V to 700 V · CMC 6 · 10⁻⁴ · U + 0,3 V 20 kHz to 50 kHz — 1 mV to 10 mV · CMC 6 · 10⁻⁴ · U + 60 µV 20 kHz to 50 kHz — 10 mV to 100 mV · CMC 1,4 · 10⁻³ · U + 55 µV 20 kHz to 50 kHz — 0,1 V to 1 V · CMC 2 · 10⁻³ · U + 0,55 mV 20 kHz to 50 kHz — 1 V to 10 V · CMC 2 · 10⁻³ · U + 5 mV 20 kHz to 50 kHz — 10 V to 100 V · CMC 2 · 10⁻³ · U + 50 mV 20 kHz to 50 kHz — 100 V to 700 V · CMC 2 · 10⁻³ · U + 0,3 V
AC voltage
Internal procedure; Direct method; Outside of permanent location (P) Internal procedure OP-W-03
17 Oscilloscopes
Scopemeters
Calibration — AC voltage
1 k Hz to 10 MHz — 50 mV to 1 V · CMC 2% 10 MHz to 100 MHz — 50 mV to 1V · CMC 2,8 % 100 MHz to 600 MHz — 50 mV to 1 V · CMC 3,5 % 0,6 GHz to 1,0 GHz — 50 mV to 1 V · CMC 6,0 % 1,0 GHz to 3,6 GHz — 50 mV to 1 V · CMC 9% 3,6 GHz to 6,5 GHz — 50 mV to 1 V · CMC 11 %
AC voltage
Internal procedure; Direct method; At permanent location (S) Internal procedure OP-W-08 based on EURAMET cg-7 v. 2.0
18 Oscilloscopes
Scopemeters
Calibration — AC voltage
10 Hz to 10 kHz; -internal AC source — 100 mV to 10 V · CMC 0,2 %
AC voltage
Internal procedure; Direct method; At permanent location (S) Internal procedure OP-W-08 based on EURAMET cg-7 v. 2.0
19 Breakdown testers
Electrical safety testers
Calibration — AC voltage
50 Hz; 60 Hz — 50 V to 1000 V · CMC 1,5 ∙ 10⁻³ ∙ U + 0,5 V
AC voltage
Internal procedure; At permanent location (S) and outside of it (P) Internal procedure OP-W-03
20 Digital ammeters
Multimeters
Power quality meters
Residual current device testers
Scopemeters (DMM)
Leakage current meters
Calibration — AC current
10 Hz to 40 Hz — 10 µA to 100 µA · CMC 5 · 10⁻⁴ · I + 15 nA 10 Hz to 40 Hz — 0,1 mA to 100 mA · CMC 3 · 10⁻⁴ · I + 0,1 µA 10 Hz to 40 Hz — 100 mA to 2 A · CMC 3 · 10⁻⁴ · I + 10 µA 50 Hz to 400 Hz — 11 A to 100 A · CMC 3 · 10⁻³ · I + 0,05 A 40 Hz to 1 kHz — 10 µA to 100 µA · CMC 1 · 10⁻⁴ · I + 10 nA 40 Hz to 1 kHz — 0,1 mA to 1 mA · CMC 1 · 10⁻⁴ · I + 50 nA 40 Hz to 1 kHz — 1 mA to 100 mA · CMC 1 · 10⁻⁴ · I + 1 µA 40 Hz to 1 kHz — 0,1 A to 2 A · CMC 2 · 10⁻⁴ · I + 0,2 mA 40 Hz to 1 kHz — 2 A to 11 A · CMC 0,06 % 1 kHz to 5 kHz — 10 µA to 100 µA · CMC 2,5 · 10⁻⁴ · I + 20 nA 1 kHz to 5 kHz — 0,1 mA to 1 mA · CMC 2 · 10⁻⁴ · I + 0,2 µA 1 kHz to 5 kHz — 1 mA to 100 mA · CMC 2 · 10⁻⁴ · I + 1,5 µA 1 kHz to 5 kHz — 0,1 A to 2 A · CMC 4 · 10⁻⁴ · I + 0,2 mA 1 kHz to 5 kHz — 2 A to 11 A · CMC 1 · 10⁻³ · I + 1 mA 5 kHz to 10 kHz — 10 µA to 100 µA · CMC 2 · 10⁻³ · I + 0,1 µA 5 kHz to 10 kHz — 0,1 mA to 1 mA · CMC 1 · 10⁻³ · I + 1 µA 5 kHz to 10 kHz — 1 mA to 100 mA · CMC 1 · 10⁻³ · I + 20 µA 5 kHz to 10 kHz — 0,1 A to 2 A · CMC 1 · 10⁻³ · I + 0,5 mA 5 kHz to 10 kHz — 2 A to 11 A · CMC 0,4 %
AC current
Internal procedure; Direct method; At permanent location (S) Internal procedure OP-W-01 based on EURAMET cg-15 v. 3
21 Clamp meters Calibration — AC current
50 Hz ;60 Hz — 0,01 A to 1 A · CMC 0,06 % 50 Hz ;60 Hz — 1 A to 10 A · CMC 0,16 % 50 Hz ;60 Hz — 10 A to 1000 A · CMC 0,43 % 400 Hz — 0,01 A to 1 A · CMC 0,06 % 400 Hz — 1 A to 10 A · CMC 0,16 % 400 Hz — 10 A to 100 A · CMC 0,43 %
AC current
Internal procedure; Direct method; At permanent location (S) Internal procedure OP-W-01
22 Calibrators
Generators
Calibration — AC current
50 Hz to 400 Hz — 11 A to 100 A · CMC 5 · 10⁻⁴ · I + 0,05 A 10 Hz to 2 kHz — 1 µA to 200 µA · CMC 3 · 10⁻⁴ · I + 5 nA 10 Hz to 2 kHz — 0,2 mA to 200 mA · CMC 0,04 % 10 Hz to 2 kHz — 0,2 A to 2 A · CMC 3 · 10⁻⁴ · I + 0,1 mA 10 Hz to 2 kHz — 2 A to 20 A · CMC 8 · 10⁻⁴ · I + 1 mA 10 Hz to 2 kHz — 20 A to 30 A · CMC 1 · 10⁻³· I + 10 mA 2 kHz to 10 kHz — 1 µA to 200 µA · CMC 5 · 10⁻⁴ · I + 10 nA 2 kHz to 10 kHz — 0,2 mA to 200 mA · CMC 0,06 % 2 kHz to 10 kHz — 0,2 A to 2 A · CMC 5 · 10⁻⁴ · I + 0,2 mA 2 kHz to 10 kHz — 2 A to 20 A · CMC 0,1 % 2 kHz to 10 kHz — 20 A to 30 A · CMC 1,5 · 10⁻³ · I + 10 mA 10 kHz to 30 kHz — 1 µA to 200 µA · CMC 8 · 10⁻⁴ · I + 10 nA 10 kHz to 30 kHz — 0,2 mA to 200 mA · CMC 0,09 % 10 kHz to 30 kHz — 0,2 A to 2 A · CMC 8 · 10⁻⁴ · I + 2 mA
AC current
Internal procedure; Direct method; At permanent location (S) Internal procedure OP-W-03
23 Power supplies Calibration — AC current
1 Hz to 2 kHz — 1 µA to 100 µA · CMC 3 · 10⁻⁴ · I + 10 nA 1 Hz to 2 kHz — 0,1 mA to 100 mA · CMC 0,04 % 1 Hz to 2 kHz — 0,1 A to 2 A · CMC 3 · 10⁻⁴ · I + 0,2 mA 1 Hz to 2 kHz — 1 A to 18,5 A · CMC 0,1 %
AC current
Internal procedure; Direct method; At permanent location (S) Internal procedure OP-W-03
24 Digital ammeters
Multimeters
Power quality meters
Residual current device testers
Scopemeters (DMM)
Leakage current meter
Calibration — AC current
50 Hz to 400 Hz — 11 A to 100 A · CMC 3 · 10⁻³ · I + 0,05 A 20 Hz to 1 kHz — 10 µA to 1 mA · CMC 1,5 · 10⁻³ · I + 50 nA 20 Hz to 1 kHz — 1 mA to 100 mA · CMC 0,1 % 20 Hz to 1 kHz — 0,1 A to 2 A · CMC 5 · 10⁻⁴ · I + 0,2 mA 20 Hz to 1 kHz — 2 A to 20 A · CMC 1,5 · 10⁻³ · I + 0,005 A 1 kHz to 5 kHz — 10 µA to 100 µA · CMC 3 · 10⁻³ · I + 0,3 µA 1 kHz to 5 kHz — 0,1 mA to 1 mA · CMC 3 · 10⁻³ · I + 1 µA 1 kHz to 5 kHz — 1 mA to 200 mA · CMC 3 · 10⁻³ · I + 0,1 mA 5 kHz to 10 kHz — 0,2 mA to 10 mA · CMC 7 · 10⁻³ · I + 2 µA 5 kHz to 10 kHz — 10 mA to 200 mA · CMC 5 · 10⁻³ · I + 0,2 mA
AC current
Internal procedure; Direct method; Outside of permanent location (P) Internal procedure OP-W-01 based on EURAMET cg-15 v. 3
25 Clamp meters Calibration — AC current
50 Hz ;60 Hz — 0,01 A to 1 A · CMC 0,1 % 50 Hz ;60 Hz — 1 A to 10 A · CMC 0,25 % 50 Hz ;60 Hz — 10 A to 1000 A · CMC 0,5 % 400 Hz — 0,01 A to 1 A · CMC 0,1 % 400 Hz — 1 A to 10 A · CMC 0,25 % 400 Hz — 10 A to 100 A · CMC 0,5 %
AC current
Internal procedure; Direct method; Outside of permanent location (P) Internal procedure OP-W-01
26 Calibrators
Generators
Calibration — AC current
50 Hz to 400 Hz — 11 A to 100 A · CMC 5 · 10⁻⁴ · I + 0,05 A 10 Hz to 2 kHz — 1 µA to 100 µA · CMC 8 · 10⁻⁴ · I + 0,35 µA 10 Hz to 2 kHz — 0,1 mA to 10 mA · CMC 1,2 · 10⁻³ · I + 0,5 µA 10 Hz to 2 kHz — 10 mA to 100 mA · CMC 1,2 · 10⁻³ · I + 20 µA 10 Hz to 2 kHz — 0,1 A to 1 A · CMC 2 · 10⁻³ · I + 1 mA 10 Hz to 2 kHz — 1 A to 3 A · CMC 2 · 10⁻³ · I + 3 mA 10 Hz to 2 kHz — 3 A to 10 A · CMC 1,5 · 10⁻³ · I + 10 mA 10 Hz to 2 kHz — 10 A to 30 A · CMC 1 · 10⁻³ · I + 10 mA 2 kHz to 5 kHz — 1 µA to 100 µA · CMC 8 · 10⁻⁴ · I + 0,35 µA 2 kHz to 5 kHz — 0,1 mA to 10 mA · CMC 1,2 · 10⁻³ · I + 0,5 µA 2 kHz to 5 kHz — 10 mA to 100 mA · CMC 1,2 · 10⁻³ · I + 20 uA 2 kHz to 5 kHz — 0,1 A to 1 A · CMC 9 · 10⁻³ · I + 1 mA 2 kHz to 5 kHz — 1 A to 3 A · CMC 9 · 10⁻³ · I + 3 mA 2 kHz to 5 kHz — 3 A to 10 A · CMC 1,5 · 10⁻³ · I + 10 mA
AC current
Internal procedure; Direct method; Outside of permanent location (P) Internal procedure OP-W-03
27 Power supplies Calibration — AC current
10 to 400 Hz — 0,1 mA to 10 mA · CMC 1,2 · 10⁻³ · I + 0,5 µA 10 to 400 Hz — 10 mA to 100 mA · CMC 1,2 · 10⁻³ · I + 20 µA 10 to 400 Hz — 0,1 A to 1 A · CMC 2 · 10⁻³ · I + 1 mA 10 to 400 Hz — 1 A to 3 A · CMC 2 · 10⁻³ · I + 3 mA 10 to 400 Hz — 3 A to 10 A · CMC 1,5 · 10⁻³ · I + 10 mA 10 to 400 Hz — 10 A to 18,5 A · CMC 1 · 10⁻³ · I + 10 mA
AC current
Internal procedure; Direct method; Outside of permanent location (P) Internal procedure OP-W-03
28 Digital ohmmeters
Multimeters
Continuity testers
Power network parameter meters
Scopemeters (DMM)
Calibration — DC resistance
100 µΩ · CMC 0,1 % 1 mΩ to 100 mΩ · CMC 0,01 % 0,1 Ω to 100 MΩ · CMC 0,005 %
DC resistance
Internal procedure; Direct method; At permanent location (S) Internal procedure OP-W-01 based on EURAMET cg-15 v. 3
29 Insulation resistance meters
Power network parameter meters
Power quality meters
Calibration — DC resistance
Test voltage up to 500 V — 50 kΩ to 1000 kΩ · CMC 0,2 % Test voltage up to 2,5 kV — 1 MΩ to 10 MΩ · CMC 0,2 % Test voltage up to 5 kV — 10 MΩ to 100 MΩ · CMC 0,2 % Test voltage up to 5 kV — 100 MΩ to 1000 MΩ · CMC 0,3 % Test voltage up to 5 kV — 1 GΩ to 10 GΩ · CMC 0,7 % Test voltage up to 5 kV — 10 GΩ to 100 GΩ · CMC 1,2 % Test voltage up to 5 kV — 100 GΩ to 5000 GΩ · CMC 2,0 %
DC resistance
Internal procedure; Direct method; At permanent location (S) Internal procedure OP-W-01
30 Shunts
Fixed resistors
Variable resistors
Calibration — DC resistance
100 µΩ · CMC 0,2 µΩ 0,001 Ω to 0,01 Ω · CMC 0,01 % 0,01 Ω to 0,1 Ω · CMC 0,02 % 0,1 Ω to 10 Ω · CMC 0,005 % 10 Ω to 1 MΩ · CMC 0,001 % 1 MΩ to 10 MΩ · CMC 0,005 % 10 MΩ to 100 MΩ · CMC 0,01 % 100 MΩ to 1 GΩ · CMC 0,1 % 1 GΩ to 20 GΩ · CMC 0,2 %
DC resistance
Internal procedure; Direct / indirect method; At permanent location (S) Internal procedure OP-W-02
31 Resistance calibrators Calibration — DC resistance
100 µΩ · CMC 0,2 µΩ 0,001 Ω to 0,01 Ω · CMC 0,01 % 0,01 Ω to 0,1 Ω · CMC 0,02 % 0,1 Ω to 10 Ω · CMC 0,005 % 10 Ω to 1 MΩ · CMC 0,001 % 1 MΩ to 10 MΩ · CMC 0,005 % 10 MΩ to 100 MΩ · CMC 0,01 % 100 MΩ to 1 GΩ · CMC 0,1 % 1 GΩ to 20 GΩ · CMC 0,2 %
DC resistance
Internal procedure; Direct / indirect method; At permanent location (S) Internal procedure OP-W-03
32 Oscilloscopes
Scopemeters
Calibration — DC resistance
10 Ω to 100 Ω · CMC 0,15 % 0,1 MΩ to 20 MΩ · CMC 0,1 %
DC resistance
Internal procedure; Direct method; At permanent location (S) Internal procedure OP-W-08 based on EURAMET cg-7 v.2.0
33 Digital ohmmeters
Multimeters
Continuity testers
Power network parameter meters
Scopemeters (DMM)
Calibration — DC resistance
50 mΩ to 300 mΩ · CMC 0,05 % 0,3 Ω to 10 MΩ · CMC 0,05 % 10 MΩ to 100 MΩ · CMC 0,1 %
DC resistance
Internal procedure; Direct method; Outside of permanent location (P) Internal procedure OP-W-01 based on EURAMET cg-15 v. 3
34 Insulation resistance meters
Power network parameter meters
Power quality meters
Calibration — DC resistance
Test voltage up to 500 V — 50 kΩ to 1000 kΩ · CMC 0,5 % Test voltage up to 2,5 kV — 1 MΩ to 10 MΩ · CMC 0,5 % Test voltage up to 5 kV — 10 MΩ to 1000 MΩ · CMC 0,5 % Test voltage up to 5 kV — 1 GΩ to 10 GΩ · CMC 1% Test voltage up to 5 kV — 10 GΩ to 100 GΩ · CMC 1,5 %
DC resistance
Internal procedure; Direct method; Outside of permanent location (P) Internal procedure OP-W-01
35 Shunts
Fixed resistors
Variable resistors
Calibration — DC resistance
100 µΩ · CMC 0,2 µΩ 0,001 Ω to 0,01 Ω · CMC 0,1 % 0,01 Ω to 0,1 Ω · CMC 0,02 % 0,1 Ω to 10 Ω · CMC 1 · 10⁻⁴ · R + 50 µΩ 10 Ω to 1 MΩ · CMC 0,01 % 1 MΩ to 100 MΩ · CMC 0,05 % 100 MΩ to 1 GΩ · CMC 0,1 %
DC resistance
Internal procedure; Direct / indirect method; Outside of permanent location (P) Internal procedure OP-W-02
36 Resistance calibrators Calibration — DC resistance
100 µΩ · CMC 0,2 µΩ 0,001 Ω to 0,01 Ω · CMC 0,1 % 0,01 Ω to 0,1 Ω · CMC 0,02 % 0,1 Ω to 10 Ω · CMC 1 · 10⁻⁴ · R + 50 µΩ 10 Ω to 1 MΩ · CMC 0,01 % 1 MΩ to 100 MΩ · CMC 0,05 % 100 MΩ to 1 GΩ · CMC 0,1 %
DC resistance
Internal procedure; Direct / indirect method; Outside of permanent location (P) Internal procedure OP-W-03
37 Digital ohmmeters
Power network parameter meters
Electrical safety testers
Calibration — AC resistance
f = 50 Hz — 0,1 Ω to 0,4 Ω · CMC 0,7 % f = 50 Hz — 0,4 Ω to 3 Ω · CMC 0,6 % f = 50 Hz — 3 Ω to 20 kΩ · CMC 0,15 %
AC resistance
Internal procedure; Direct method; At permanent location (S) and outside of it (P) Internal procedure OP-W-01
38 Fault loop impedance meters
Residual current device testers
Calibration — AC resistance
f = 50 Hz — 100 mΩ to 250 mΩ · CMC 0,6 % f = 50 Hz — 250 mΩ to 1000 mΩ · CMC 0,3 % f = 50 Hz — 1000 mΩ to 2000 mΩ · CMC 0,12 % f = 50 Hz — 2 Ω to 19 Ω · CMC 0,3 % f = 50 Hz — 19 Ω to 2 kΩ · CMC 0,1 %
AC resistance
Internal procedure; Direct method; At permanent location (S) and outside of it (P) Internal procedure OP-W-01
39 Earth resistance meters Calibration — AC resistance
50 Hz to 125 Hz — 0,1 Ω to 0,4 Ω · CMC 0,7 % 50 Hz to 125 Hz — 0,4 Ω to 3 Ω · CMC 0,6 % 50 Hz to 125 Hz — 3 Ω to 20 kΩ · CMC 0,15 %
AC resistance
Internal procedure; Direct method; At permanent location (S) and outside of it (P) Internal procedure OP-W-01
40 Earth continuity testers Calibration — AC resistance
50 Hz to 60 Hz — 100 mΩ to 250 mΩ · CMC 0,6 % 50 Hz to 60 Hz — 250 mΩ to 1000 mΩ · CMC 0,3 % 50 Hz to 60 Hz — 1000 mΩ to 2000 mΩ · CMC 0,12 % 50 Hz to 60 Hz — 2 Ω to 19 Ω · CMC 0,3 % 50 Hz to 60 Hz — 19 Ω to 2 kΩ · CMC 0,1 %
AC resistance
Internal procedure; Direct method; At permanent location (S) and outside of it (P) Internal procedure OP-W-01
41 Power network parameter meters Calibration — Phase angle
50 Hz; 10 V to 280 V; 0,1 A to 1000 A — 0° to 360° · CMC 0,2° 50 Hz; 10 V to 280 V; 0,1 A to 1000 A — cosφ ±<1 to 0,5> · CMC 0,0028 50 Hz; 280 V to 1000 V; 0,1 A to 1000 A — 0° to 360° · CMC 0,6° 50 Hz; 280 V to 1000 V; 0,1 A to 1000 A — cosφ ±<1 to 0,5> · CMC 0,0088
Phase angle
Internal procedure; Direct method; At permanent location (S) and outside of it (P) Internal procedure OP-W-01 based on EURAMET cg 15 v.3.0
42 Power meters
Power quality meters
Power network parameter meters
Calibration — DC power
10 V to 1000 V; 0,1 A to 20 A — 1 W to 20 kW · CMC 0,05 %
DC power
Internal procedure; Direct method; At permanent location (S) and outside of it (P) Internal procedure OP-W-01 based on EURAMET cg-15 v. 3.0
43 Power meters
Power quality meters
Power network parameter meters
Calibration — DC power
10 V to 1000 V; 10 A to 1000 A — 100 W to 1 MW · CMC 0,40 %
DC power
Internal procedure; Direct method. Clamp measurement; At permanent location (S) and outside of it (P) Internal procedure OP-W-01 based on EURAMET cg-15 v. 3.0
44 Digital single-phase active power meters
Digital three-phase active power meters
Digital single-phase apparent power meters
Digital three-phase apparent power meters
Digital single-phase reactive power meters
Digital three-phase reactive power meters
Power quality meters
Power network parameter meters
Calibration — AC power
50 Hz; 10 V to 1000 V; 0,1 A to 20 A; cosφ / sinφ ±1 — 1 W to 20 kW · CMC 0,13 % 50 Hz; 10 V to 1000 V; 0,1 A to 20 A; cosφ / sinφ ±1 — 1 VA to 20 kVA · CMC 0,13 % 50 Hz; 10 V to 1000 V; 0,1 A to 20 A; cosφ / sinφ ±1 — 1 var to 20 kvar · CMC 0,13 % 50 Hz; 10 V to 1000 V; 0,1 A to 20 A; inductive or capacitive cosφ and sinφ; cosφ ± (1 to 0,5>; sinφ ± (1 to 0,5> — 0,5 W to 10 kW · CMC 0,48 % 50 Hz; 10 V to 1000 V; 0,1 A to 20 A; inductive or capacitive cosφ and sinφ; cosφ ± (1 to 0,5>; sinφ ± (1 to 0,5> — 1 VA to 20 kVA · CMC 0,13 % 50 Hz; 10 V to 1000 V; 0,1 A to 20 A; inductive or capacitive cosφ and sinφ; cosφ ± (1 to 0,5>; sinφ ± (1 to 0,5> — 0,5 var to 10 kvar · CMC 0,48 %
AC power
Internal procedure; Direct method. Three-phase measurement performed phase by phase; At permanent location (S) and outside of it (P) Internal procedure OP-W-01 based on EURAMET cg-15 v. 3.0
45 Digital single-phase active power meters
Digital three-phase active power meters
Digital single-phase apparent power meters
Digital three-phase apparent power meters
Digital single-phase reactive power meters
Digital three-phase reactive power meters
Power quality meters
Power network parameter meters
Calibration — AC power
50 Hz; 10 V to 1000 V; 10 A to 1000 A; cosφ / sinφ ±1 — 100 W to 1 MW · CMC 0,45 % 50 Hz; 10 V to 1000 V; 10 A to 1000 A; cosφ / sinφ ±1 — 100 VA to 1 MVA · CMC 0,45 % 50 Hz; 10 V to 1000 V; 10 A to 1000 A; cosφ / sinφ ±1 — 100 var to 1 Mvar · CMC 0,45 % 50 Hz; 10 V to 1000 V; 10 A to 1000 A; inductive or capacitive cosφ and sinφ; cosφ ± (1 to 0,5>; sinφ ± (1 to 0,5> — 50 W to 0,5 MW · CMC 0,65 % 50 Hz; 10 V to 1000 V; 10 A to 1000 A; inductive or capacitive cosφ and sinφ; cosφ ± (1 to 0,5>; sinφ ± (1 to 0,5> — 100 VA to 1 MVA · CMC 0,45 % 50 Hz; 10 V to 1000 V; 10 A to 1000 A; inductive or capacitive cosφ and sinφ; cosφ ± (1 to 0,5>; sinφ ± (1 to 0,5> — 50 var to 0,5 Mvar · CMC 0,65 %
AC power
Internal procedure; Direct method. Clamp measurement. Three-phase measurement performed phase by phase; At permanent location (S) and outside of it (P) Internal procedure OP-W-01 based on EURAMET cg-15 v. 3.0
46 Breakdown testers
Electrical safety testers
Voltage sources
Calibration — High voltage and current
DC voltage — 1 kV to 10 kV · CMC 0,05 % DC voltage — 10 kV to 35 kV · CMC 0,1 % AC voltage at 50 Hz; 60 Hz — 1 kV to 10 kV · CMC 0,15 % AC voltage at 50 Hz; 60 Hz — 10 kV to 30 kV · CMC 0,2 %
High voltage and current
Internal procedure; At permanent location (S) and outside of it (P) Internal procedure OP-W-03
47 Temperature simulators (resistance) Calibration — Electrical simulation of quantities
-200 oC to 250 oC · CMC 0,007 oC 250 oC to 850 oC · CMC 0,015 oC
Electrical simulation of quantities
Internal procedure; Indirect method; At permanent location (S) Internal procedure OP-W-03 based on EURAMET cg-11 v. 2
48 Temperature indicators (meters) for use with resistance sensors Calibration — Electrical simulation of quantities
-200 oC to 250 oC · CMC 0,007 oC 250 oC to 850 oC · CMC 0,015 oC
Electrical simulation of quantities
Internal procedure; Indirect method; At permanent location (S) Internal procedure OP-W-01 based on EURAMET cg-11 v. 2
49 Temperature simulators (resistance) Calibration — Electrical simulation of quantities
-200 °C to 850 °C · CMC 0,06 °C
Electrical simulation of quantities
Internal procedure; Indirect method; Outside of permanent location (P) Internal procedure OP-W-03 based on EURAMET cg-11 v. 2
50 Temperature indicators (meters) for use with resistance sensors Calibration — Electrical simulation of quantities
-200 °C to 850 °C · CMC 0,06 °C
Electrical simulation of quantities
Internal procedure; Indirect method; Outside of permanent location (P) Internal procedure OP-W-01 based on EURAMET cg-11 v. 2
51 Oscilloscopes
Scopemeters
Calibration — Time (time interval)
10 ns to 10 s · CMC 1 ∙ 10⁻⁶ ∙ t + 1,5 ns
Time (time interval)
Internal procedure; Direct method; At permanent location (S) Internal procedure OP-W-08 based on EURAMET cg-7 v. 2.0
52 Multimeters
Digital frequency meters
Power network parameter meters
Calibration — Frequency
Square-wave signal — 1 Hz to 10 Hz · CMC 3 · 10⁻⁸ · f Square-wave signal — 10 Hz to 50 MHz · CMC 3 · 10⁻⁹ · f Sine-wave signal — 1 Hz to 10 Hz · CMC 1 · 10⁻⁴ · f + 0,001 Hz Sine-wave signal — 10 Hz to 100 Hz · CMC 1 · 10⁻⁵ · f + 0,001 Hz Sine-wave signal — 100 Hz to 1 kHz · CMC 1 · 10⁻⁶ · f + 0,001 Hz Sine-wave signal — 1 kHz to 10 kHz · CMC 1 · 10⁻⁷ · f + 0,001 Hz Sine-wave signal — 10 kHz to 350 kHz · CMC 2 · 10⁻⁸ · f Sine-wave signal — 350 kHz to 5 GHz · CMC 3 · 10⁻⁹ · f
Frequency
Internal procedure; Direct method; At permanent location (S) Internal procedure OP-W-07
53 Frequency generators
Calibrators
Calibration — Frequency
Square-wave signal — 1 Hz to 10 Hz · CMC 3 · 10⁻⁸ · f Square-wave signal — 10 Hz to 500 MHz · CMC 3 · 10⁻⁹ · f Sine-wave signal — 1 Hz to 10 Hz · CMC 1 · 10⁻⁴ · f + 0,001 Hz Sine-wave signal — 10 Hz to 100 Hz · CMC 1 · 10⁻⁵ · f + 0,001 Hz Sine-wave signal — 100 Hz to 1 kHz · CMC 1 · 10⁻⁶ · f + 0,001 Hz Sine-wave signal — 1 kHz to 10 kHz · CMC 1 · 10⁻⁷ · f + 0,001 Hz Sine-wave signal — 10 kHz to 350 kHz · CMC 2 · 10⁻⁸ · f Sine-wave signal — 350 kHz to 5 GHz · CMC 3 · 10⁻⁹ · f
Frequency
Internal procedure; Direct method; At permanent location (S) Internal procedure OP-W-07
54 Oscilloscopes
Scopemeters
Calibration — Frequency
- internal AC source — 10 Hz to 100 kHz · CMC 1 ∙ 10⁻⁶ ∙ f + 0,001 Hz
Frequency
Internal procedure; Direct method; At permanent location (S) Internal procedure OP-W-08
55 Multimeters
Digital frequency meters
Power network parameter meters
Calibration — Frequency
Square-wave signal — 1 Hz to 10 Hz · CMC 3 · 10⁻⁵ · f + 0,01 Hz Square-wave signal — 10 Hz to 50 MHz · CMC 3 · 10⁻⁶ · f Sine-wave signal — 1 Hz to 10 Hz · CMC 5 · 10⁻² · f + 0,01 Hz Sine-wave signal — 10 Hz to 100 Hz · CMC 1 · 10⁻² · f + 0,01 Hz Sine-wave signal — 100 Hz to 1 kHz · CMC 1 · 10⁻³ · f + 0,01 Hz Sine-wave signal — 1 kHz to 10 kHz · CMC 1 · 10⁻⁴ · f + 0,01 Hz Sine-wave signal — 10 kHz to 350 kHz · CMC 3 · 10⁻⁵ · f Sine-wave signal — 350 kHz to 160 MHz · CMC 3 · 10⁻⁶ · f
Frequency
Internal procedure; Direct method; Outside of permanent location (P) Internal procedure OP-W-07
56 Frequency generators
Calibrators
Calibration — Frequency
Square-wave signal — 1 Hz to 10 Hz · CMC 3 · 10⁻⁵ · f + 0,01 Hz Square-wave signal — 10 Hz to 200 MHz · CMC 3 · 10⁻⁶ · f Sine-wave signal — 1 Hz to 10 Hz · CMC 5 · 10⁻² · f + 0,01 Hz Sine-wave signal — 10 Hz to 100 Hz · CMC 1 · 10⁻² · f + 0,01 Hz Sine-wave signal — 100 Hz to 1 kHz · CMC 1 · 10⁻³ · f + 0,01 Hz Sine-wave signal — 1 kHz to 10 kHz · CMC 1 · 10⁻⁴ · f + 0,01 Hz Sine-wave signal — 10 kHz to 350 kHz · CMC 3 · 10⁻⁵ · f Sine-wave signal — 350 kHz to 200 MHz · CMC 3 · 10⁻⁶ · f
Frequency
Internal procedure; Direct method; Outside of permanent location (P) Internal procedure OP-W-07
57 Thermohygrometers Calibration — Relative humidity
10 °C to 30 °C; 10 %rh to 90 %rh — 10 % rh · CMC 1,1 %rh 10 °C to 30 °C; 10 %rh to 90 %rh — 90 %rh · CMC 1,6 %rh 30 °C to 50 °C; 10 %rh to 90 %rh — 10 % rh · CMC 1,1 %rh 30 °C to 50 °C; 10 %rh to 90 %rh — 90 %rh · CMC 2,1 %rh 50 °C to 60 °C; 10 %rh to 90 %rh — 10 % rh · CMC 2,2 %rh 50 °C to 60 °C; 10 %rh to 90 %rh — 90 %rh · CMC 2,5 %rh
Relative humidity
Internal procedure; Direct method; At permanent location (S) Internal procedure OP-W-05-01
58 Thermohygrometers Calibration — Relative humidity
10 °C to 20 °C; 25 %rh to 90 %rh — 25 % rh · CMC 1,2 %rh 10 °C to 20 °C; 25 %rh to 90 %rh — 90 %rh · CMC 2,0 %rh 20 °C to 30 °C; 15 %rh to 90 %rh — 15 % rh · CMC 1,1 %rh 20 °C to 30 °C; 15 %rh to 90 %rh — 90 %rh · CMC 1,9 %rh 30 °C to 50 °C; 10 %rh to 90 %rh — 10 %rh · CMC 1,6 %rh 30 °C to 50 °C; 10 %rh to 90 %rh — 90 %rh · CMC 2,2 %rh
Relative humidity
Internal procedure; Direct method; Outside of permanent location (P) Internal procedure OP-W-05-01
59 Electronic pressure gauges
Bourdon tube pressure gauges
Calibration — Pressure
- gauge pressure (gas) — -100 kPa to -5 kPa · CMC 0,010 kPa - gauge pressure (gas) — -5 kPa to 5 kPa · CMC 0,058 kPa - gauge pressure (gas) — 5 kPa to 100 kPa · CMC 0,010 kPa - gauge pressure (gas) — 100 kPa to 200 kPa · CMC 0,058 kPa - gauge pressure (gas) — 200 kPa to 600 kPa · CMC 1,0 kPa - gauge pressure (gas) — 600 kPa to 1000 kPa · CMC 0,071 kPa - gauge pressure (gas) — 1000 kPa to 12000 kPa · CMC 0,0071 %
Pressure
Internal procedure; Method 5.2.3. Direct method; At permanent location (S) Internal procedure OP-W-06-01 based on EURAMET cg-17 v.4.1
60 Electronic pressure gauges
Bourdon tube pressure gauges
Calibration — Pressure
- gauge pressure (liquid) — -100 kPa to 200 kPa · CMC 0,058 kPa - gauge pressure (liquid) — 200 kPa to 600 kPa · CMC 1,0 kPa - gauge pressure (liquid) — 600 kPa to 1000 kPa · CMC 0,082 kPa - gauge pressure (liquid) — 1000 kPa to 7000 kPa · CMC 0,0082 % - gauge pressure (liquid) — 7000 kPa to 70000 kPa · CMC 0,0074 %
Pressure
Internal procedure; Method 5.2.3. Direct method; At permanent location (S) Internal procedure OP-W-06-01 based on EURAMET cg-17 v.4.1
61 Electronic pressure gauges
Bourdon tube pressure gauges
Calibration — Pressure
- differential pressure (gas) — -10 kPa to -1 kPa · CMC 0,012 kPa - differential pressure (gas) — -1 kPa to 1 kPa · CMC 0,0012 kPa - differential pressure (gas) — 1 kPa to 10 kPa · CMC 0,012 kPa
Pressure
Internal procedure; Method 5.2.3. Direct method; At permanent location (S) Internal procedure OP-W-06-01 based on EURAMET cg-17 v.4.1
62 Electronic pressure gauges
Bourdon tube pressure gauges
Calibration — Pressure
- gauge pressure (gas) — -100 kPa to -10 kPa · CMC 0,058 kPa - gauge pressure (gas) — -10 kPa to -1 kPa · CMC 0,012 kPa - gauge pressure (gas) — -1 kPa to 1 kPa · CMC 0,0012 kPa - gauge pressure (gas) — 1 kPa to 10 kPa · CMC 0,012 kPa - gauge pressure (gas) — 10 kPa to 200 kPa · CMC 0,058 kPa - gauge pressure (gas) — 200 kPa to 3500 kPa · CMC 1,0 kPa - gauge pressure (gas) — 3500 kPa to 6000 kPa · CMC 10 kPa
Pressure
Internal procedure; Method 5.2.3. Direct method; Outside of permanent location (P) Internal procedure OP-W-06-01 based on EURAMET cg-17 v.4.1
63 Electrical thermometers (including electronic)
Electrical thermometers (with temperature recording)
Calibration — Temperature (electrical thermometry)
-35 °C do 0 °C · CMC 0,05 °C 0 °C · CMC 0,03 °C 0 °C do 80 °C · CMC 0,06 °C 80 °C do 155 °C · CMC 0,07 °C 155 °C do 180 °C · CMC 0,08 °C 180 °C to 300 °C · CMC 0,14 °C 300 °C do 400 °C · CMC 0,52 °C
Temperature (electrical thermometry)
Internal procedure; Direct method; At permanent location (S) Internal procedure OP-W-04-01
64 Electrical thermometers (including electronic)
Electrical thermometers (with temperature recording)
Calibration — Temperature (electrical thermometry)
-35 °C to 100 °C · CMC 0,07 °C 100 °C to 150 °C · CMC 0,18 °C 150 °C to 180 °C · CMC 0,30 °C 180 °C to 200 °C · CMC 0,34 °C 200 °C to 250 °C · CMC 0,44 °C 250 °C to 300 °C · CMC 0,51 °C 300 °C to 350 °C · CMC 0,64 °C 350 °C to 400 °C · CMC 0,70 °C
Temperature (electrical thermometry)
Internal procedure; Direct method; Outside of permanent location (P) Internal procedure OP-W-04-01
65 Electrical thermometers (including electronic)
Electrical thermometers (with temperature recording)
Calibration — Temperature (electrical thermometry)
-5 °C to 0 °C · CMC 0,37 °C 0 °C to 10 °C · CMC 0,27 °C 0 °C to 15 °C · CMC 0,21 °C 15 °C to 45 °C · CMC 0,14 °C 45 °C to 50 °C · CMC 0,21 °C 45 °C to 60 °C · CMC 0,28 °C
Temperature (electrical thermometry)
Internal procedure; Calibration in a climatic chamber. Direct method; At permanent location (S) Internal procedure OP-W-04-01

Reference standards (15)

EURAMET cg 15 v.3.0
EURAMET cg-11 v. 2
EURAMET cg-15 v. 3
EURAMET cg-15 v. 3.0
EURAMET cg-17 v.4.1
EURAMET cg-7 v. 2.0
EURAMET cg-7 v.2.0
OP-W-01
OP-W-02
OP-W-03
OP-W-04-01
OP-W-05-01
OP-W-06-01
OP-W-07
OP-W-08

The same scope as data (JSON): https://labcoda.pl/api/accreditation-scopes/labs/PL/AP%20215