🇵🇱 Merserwis Spółka z ograniczoną odpowiedzialnością Sp. K. PL
Metrology & calibration
Merserwis Spółka z ograniczoną odpowiedzialnością Sp. K. is a calibration laboratory accredited by PCA under number AP 215 (Warszawa, Poland). Its accreditation scope covers 65 calibration items in the following areas: Metrology & calibration. Calibrated items include: Power quality meters, Multimeters, Power network parameter meters, Calibrators. Most frequently used calibration principles: Internal procedure; Direct method; At permanent location (S), Internal procedure; Direct method; Outside of permanent location (P), Internal procedure; Direct method; At permanent location (S) and ou….
At a glance
- Accreditation number: PCA AP 215
- Calibration items in scope: 65
- Types of calibrated items: 47
- Calibration principles used: 17
- City: Warszawa, Poland
- Valid until: 03-01-2027
- Accreditation number
- AP 215
- Accreditation body
- PCA
- Address
- ul. Gen. Wł. Andersa 10, 00-201 Warszawa
- City
- Warszawa, Poland
- Valid until
- 03-01-2027
What this laboratory calibrates (47)
- Power quality meters — 14 calibration items
- Multimeters — 12 calibration items
- Power network parameter meters — 12 calibration items
- Calibrators — 10 calibration items
- Scopemeters (DMM) — 10 calibration items
- Clamp meters — 8 calibration items
- Power supplies — 7 calibration items
- Oscilloscopes — 6 calibration items
- Scopemeters — 6 calibration items
- Residual current device testers — 5 calibration items
- Bourdon tube pressure gauges — 4 calibration items
- Digital ammeters — 4 calibration items
- Digital voltmeters — 4 calibration items
- Electrical safety testers — 4 calibration items
- Electronic pressure gauges — 4 calibration items
- and 32 more
Calibration principles (17)
- Internal procedure; Direct method; At permanent location (S) — 20 calibration items
- Internal procedure; Direct method; Outside of permanent location (P) — 15 calibration items
- Internal procedure; Direct method; At permanent location (S) and outside of it (P) — 6 calibration items
- Internal procedure; At permanent location (S) and outside of it (P) — 3 calibration items
- Internal procedure; Method 5.2.3. Direct method; At permanent location (S) — 3 calibration items
- Internal procedure; Direct / indirect method; At permanent location (S) — 2 calibration items
- Internal procedure; Direct / indirect method; Outside of permanent location (P) — 2 calibration items
- Internal procedure; Indirect / direct method; At permanent location (S) — 2 calibration items
- Internal procedure; Indirect / direct method; Outside of permanent location (P) — 2 calibration items
- Internal procedure; Indirect method; At permanent location (S) — 2 calibration items
- Internal procedure; Indirect method; Outside of permanent location (P) — 2 calibration items
- Internal procedure; Calibration in a climatic chamber. Direct method; At permanent location (S) — 1 calibration item
- Internal procedure; Direct and indirect method; At permanent location (S) — 1 calibration item
- Internal procedure; Direct method. Clamp measurement; At permanent location (S) and outside of it (P) — 1 calibration item
- Internal procedure; Direct method. Clamp measurement. Three-phase measurement performed phase by phase; At permanent location (S) and outside of it (P) — 1 calibration item
- and 2 more
Certificate information
- Issue date
- 17.04.2026
- Issue no.
- 5
- Certificate date
- 04.01.2023
- Accreditation cycle
- 04.01.2023 — 03.01.2027
- Approved by
- Katarzyna Wiśniewska
Accreditation scope — calibration items (65)
| No. | Calibrated quantity / subject of calibration | Nominal range / parameters / CMC | Calibration principle | Calibration procedure | |
|---|---|---|---|---|---|
| Calibration items | |||||
| 1 | Digital voltmeters Multimeters Power quality meters Clamp meters Scopemeters (DMM) |
Calibration — DC voltage 0,1 mV to 200 mV · CMC 5 · 10⁻⁶ · U + 0,3 µV 0,2 V to 20 V · CMC 0,0004 % 20 V to 200 V · CMC 0,0005 % 200 V to 1000 V · CMC 5 · 10⁻⁶ · U + 0,5 mV DC voltage |
Internal procedure; Indirect / direct method; At permanent location (S) | Internal procedure OP-W-01 based on EURAMET cg-15 v. 3 | |
| 2 | Calibrators Reference sources Power supplies |
Calibration — DC voltage 0,1 mV to 200 mV · CMC 5 · 10⁻⁶ · U + 0,3 µV 0,2 V to 20 V · CMC 0,0004 % 20 V to 200 V · CMC 0,0005 % 200 V to 1000 V · CMC 5 · 10⁻⁶ · U + 0,5 mV DC voltage |
Internal procedure; Direct method; At permanent location (S) | Internal procedure OP-W-03 | |
| 3 | Digital voltmeters Multimeters Power quality meters Clamp meters Scopemeters (DMM) |
Calibration — DC voltage 0,1 mV to 200 mV · CMC 5 · 10⁻⁶ · U + 6 µV 0,2 V to 2 V · CMC 1 · 10⁻⁵ · U + 30 µV 2 V to 20 V · CMC 3 · 10⁻⁵ · U + 0,5 mV 20 V to 200 V · CMC 4 · 10⁻⁵ · U + 2 mV 200 V to 1000 V · CMC 0,005 % DC voltage |
Internal procedure; Indirect / direct method; Outside of permanent location (P) | Internal procedure OP-W-01 based on EURAMET cg-15 v. 3 | |
| 4 | Calibrators Reference sources Power supplies |
Calibration — DC voltage 0,1 mV to 200 mV · CMC 5 · 10⁻⁶ · U + 6 µV 0,2 V to 2 V · CMC 1 · 10⁻⁵ · U + 30 µV 2 V to 20 V · CMC 3 · 10⁻⁵ · U + 0,5 mV 20 V to 200 V · CMC 4 · 10⁻⁵ · U + 2 mV 200 V to 1000 V · CMC 0,005 % DC voltage |
Internal procedure; Direct method; Outside of permanent location (P) | Internal procedure OP-W-03 | |
| 5 | Oscilloscopes Scopemeters |
Calibration — DC voltage 1 mV to 280 V · CMC 5 ∙ 10⁻⁴ ∙ U + 60 µV DC voltage |
Internal procedure; Direct method; At permanent location (S) | Internal procedure OP-W-08 based on EURAMET cg-7 v. 2.0 | |
| 6 | Breakdown testers Electrical safety testers |
Calibration — DC voltage 50 V to 1000 V · CMC 1,5 ∙ 10⁻⁴ ∙ U + 0,5 V DC voltage |
Internal procedure; At permanent location (S) and outside of it (P) | Internal procedure OP-W-03 | |
| 7 | Digital ammeters Multimeters Power quality meters Scopemeters (DMM) |
Calibration — DC current 1 µA to 200 µA · CMC 5 · 10⁻⁵ · I + 6 nA 0,2 mA to 20 mA · CMC 3,5 · 10⁻⁵ · I + 0,1 µA 20 mA to 200 mA · CMC 5 · 10⁻⁵ · I + 1 µA 0,2 A to 2 A · CMC 0,025 % 2 A to 10 A · CMC 3 · 10⁻⁴ · I + 0,1 mA 10 A to 20 A · CMC 0,03 % 20 A to 38 A · CMC 3 · 10⁻⁴ · I + 15 mA DC current |
Internal procedure; Direct and indirect method; At permanent location (S) | Internal procedure OP-W-01 based on EURAMET cg-15 v. 3 | |
| 8 | Clamp meters | Calibration — DC current 1 mA to 1 A · CMC 0,016 % 1 A to 10 A · CMC 0,04 % 10 A to 1000 A · CMC 0,33 % DC current |
Internal procedure; Direct method; At permanent location (S) | Internal procedure OP-W-01 | |
| 9 | Calibrators DC current sources Power supplies |
Calibration — DC current 1 µA to 200 µA · CMC 2 · 10⁻⁵ · I + 0,5 nA 0,2 mA to 20 mA · CMC 2 · 10⁻⁵ · I + 10 nA 20 mA to 200 mA · CMC 4 · 10⁻⁵ · I + 2 µA 0,2 A to 2 A · CMC 0,02 % 2 A to 20 A · CMC 0,03 % 20 A to 30 A · CMC 0,02 % 30 A to 200 A · CMC 2 · 10⁻⁴ · I + 0,02 A DC current |
Internal procedure; Direct method; At permanent location (S) | Internal procedure OP-W-03 | |
| 10 | Digital ammeters Multimeters Power quality meters Scopemeters (DMM) |
Calibration — DC current 1 µA to 100 µA · CMC 5 · 10⁻⁴ · I + 30 nA 0,1 mA to 100 mA · CMC 5 · 10⁻⁴ · I + 0,1 µA 0,1 A to 1 A · CMC 2 · 10⁻⁴ · I + 0,5 mA 1 A to 2 A · CMC 0,03 % 2 A to 10 A · CMC 0,1 % 10 A to 20 A · CMC 0,04 % DC current |
Internal procedure; Direct method; Outside of permanent location (P) | Internal procedure OP-W-01 based on EURAMET cg-15 v. 3 | |
| 11 | Clamp meters | Calibration — DC current 1 mA to 1 A · CMC 0,03 % 1 A to 10 A · CMC 0,12 % 10 A to 1000 A · CMC 0,4 % DC current |
Internal procedure; Direct method; Outside of permanent location (P) | Internal procedure OP-W-01 | |
| 12 | Calibrators DC current sources Power supply |
Calibration — DC current 1 µA to 100 µA · CMC 1 · 10⁻⁴ · I + 1 nA 0,1 mA to 10 mA · CMC 1 · 10⁻⁴ · I + 0,1 µA 10 mA to 100 mA · CMC 2 · 10⁻⁴ · I + 5 µA 0,1 A to 1 A · CMC 5 · 10⁻⁴ · I + 0,1 mA 1 A to 3 A · CMC 5 · 10⁻⁴ · I + 0,1 mA 3 A to 30 A · CMC 3 · 10⁻⁴ · I + 0,001 mA 30 A to 200 A · CMC 2 · 10⁻⁴ · I + 0,02 A DC current |
Internal procedure; Direct method; Outside of permanent location (P) | Internal procedure OP-W-03 | |
| 13 | Digital voltmeters Multimeters Power quality meters Clamp meters Residual current device testers Scopemeters (DMM) |
Calibration — AC voltage 10 Hz to 2 kHz — 1 mV to 10 mV · CMC 2 · 10⁻⁴ · U + 2 µV 10 Hz to 2 kHz — 10 mV to 100 mV · CMC 7 · 10⁻⁵ · U + 1 µV 10 Hz to 2 kHz — 0,1 V to 1 V · CMC 8 · 10⁻⁵·U + 5 µV 10 Hz to 2 kHz — 1 V to 10 V · CMC 8 · 10⁻⁵ · U + 50 µV 10 Hz to 2 kHz — 10 V to 100 V · CMC 8 · 10⁻⁵ · U + 0,5 mV 10 Hz to 2 kHz — 100 V to 1000 V · CMC 1 · 10⁻⁴ · U + 0,03 V 2 kHz to 10 kHz — 1 mV to 10 mV · CMC 3 · 10⁻⁴ · U + 2 µV 2 kHz to 10 kHz — 10 mV to 100 mV · CMC 1,2 · 10⁻⁴ · U + 1 µV 2 kHz to 10 kHz — 0,1 V to 100 V · CMC 0,015 % 2 kHz to 10 kHz — 100 V to 1000 V · CMC 1 · 10⁻⁴ · U + 0,03 V 10 kHz to 30 kHz — 1 mV to 10 mV · CMC 3·10⁻⁴·U + 2 µV 10 kHz to 30 kHz — 10 mV to 100 mV · CMC 2,2 · 10⁻⁴ · U + 1 µV 10 kHz to 30 kHz — 0,1 V to 100 V · CMC 0,03 % 10 kHz to 30 kHz — 100 V to 1000 V · CMC 0,035 % 30 kHz to 100 kHz — 1 mV to 10 mV · CMC 3,5 · 10⁻³ · U + 2 µV 30 kHz to 100 kHz — 10 mV to 100 mV · CMC 8 · 10⁻⁴ · U + 1 µV 30 kHz to 100 kHz — 0,1 V to 100 V · CMC 0,08 % 30 kHz to 100 kHz — 100 V to 1000 V · CMC 0,12 % 100 kHz to 300 kHz — 1 mV to 10 mV · CMC 1,5 % 100 kHz to 300 kHz — 10 mV to 10 V · CMC 0,5 % 100 kHz to 300 kHz — 10 V to 100 V · CMC 0,8 % 300 kHz to 1 MHz — 10 mV to 1 V · CMC 1,5 · 10⁻² · U + 0,5 mV 300 kHz to 1 MHz — 1 V to 10 V · CMC 1,5 · 10⁻² · U + 5 mV 300 kHz to 1 MHz — 10 V to 100 V · CMC 3,5 · 10⁻² · U + 10 mV AC voltage |
Internal procedure; Indirect / direct method; At permanent location (S) | Internal procedure OP-W-01 based on EURAMET cg-15 v. 3 | |
| 14 | Calibrators Power supplies |
Calibration — AC voltage 10 Hz to 2 kHz — 1 mV to 10 mV · CMC 2 · 10⁻⁴ · U + 2 µV 10 Hz to 2 kHz — 10 mV to 100 mV · CMC 7 · 10⁻⁵ · U + 1 µV 10 Hz to 2 kHz — 0,1 V to 1 V · CMC 8 · 10⁻⁵·U + 5 µV 10 Hz to 2 kHz — 1 V to 10 V · CMC 8 · 10⁻⁵ · U + 50 µV 10 Hz to 2 kHz — 10 V to 100 V · CMC 8 · 10⁻⁵ · U + 0,5 mV 10 Hz to 2 kHz — 100 V to 1000 V · CMC 1 · 10⁻⁴ · U + 0,03 V 2 kHz to 10 kHz — 1 mV to 10 mV · CMC 3 · 10⁻⁴ · U + 2 µV 2 kHz to 10 kHz — 10 mV to 100 mV · CMC 1,2 · 10⁻⁴ · U + 1 µV 2 kHz to 10 kHz — 0,1 V to 100 V · CMC 0,015 % 2 kHz to 10 kHz — 100 V to 1000 V · CMC 1 · 10⁻⁴ · U + 0,03 V 10 kHz to 30 kHz — 1 mV to 10 mV · CMC 3·10⁻⁴·U + 2 µV 10 kHz to 30 kHz — 10 mV to 100 mV · CMC 2,2 · 10⁻⁴ · U + 1 µV 10 kHz to 30 kHz — 0,1 V to 100 V · CMC 0,03 % 10 kHz to 30 kHz — 100 V to 1000 V · CMC 0,035 % 30 kHz to 100 kHz — 1 mV to 10 mV · CMC 3,5 · 10⁻³ · U + 2 µV 30 kHz to 100 kHz — 10 mV to 100 mV · CMC 8 · 10⁻⁴ · U + 1 µV 30 kHz to 100 kHz — 0,1 V to 100 V · CMC 0,08 % 30 kHz to 100 kHz — 100 V to 1000 V · CMC 0,12 % 100 kHz to 300 kHz — 1 mV to 10 mV · CMC 1,5 % 100 kHz to 300 kHz — 10 mV to 10 V · CMC 0,5 % 100 kHz to 300 kHz — 10 V to 100 V · CMC 0,8 % 300 kHz to 1 MHz — 10 mV to 1 V · CMC 1,5 · 10⁻² · U + 0,5 mV 300 kHz to 1 MHz — 1 V to 10 V · CMC 1,5 · 10⁻² · U + 5 mV 300 kHz to 1 MHz — 10 V to 100 V · CMC 3,5 · 10⁻² · U + 10 mV AC voltage |
Internal procedure; Direct method; At permanent location (S) | Internal procedure OP-W-03 | |
| 15 | Digital voltmeters Multimeters Power quality meters Clamp meters Residual current device testers Scopemeters (DMM) |
Calibration — AC voltage 10 Hz to 20 kHz — 1 mV to 100 mV · CMC 6 · 10⁻⁴ · U + 50 µV 10 Hz to 20 kHz — 0,1 V to 1 V · CMC 6 · 10⁻⁴ · U + 0,5 mV 10 Hz to 20 kHz — 1 V to 10 V · CMC 6 · 10⁻⁴ · U + 5 mV 10 Hz to 20 kHz — 10 V to 100 V · CMC 6 · 10⁻⁴ · U + 50 mV 10 Hz to 20 kHz — 100 V to 700 V · CMC 6 · 10⁻⁴ · U + 0,3 V 20 kHz to 50 kHz — 1 mV to 10 mV · CMC 6 · 10⁻⁴ · U + 60 µV 20 kHz to 50 kHz — 10 mV to 100 mV · CMC 1,4 · 10⁻³ · U + 55 µV 20 kHz to 50 kHz — 0,1 V to 1 V · CMC 2 · 10⁻³ · U + 0,55 mV 20 kHz to 50 kHz — 1 V to 10 V · CMC 2 · 10⁻³ · U + 5 mV 20 kHz to 50 kHz — 10 V to 100 V · CMC 2 · 10⁻³ · U + 50 mV 20 kHz to 50 kHz — 100 V to 700 V · CMC 2 · 10⁻³ · U + 0,3 V AC voltage |
Internal procedure; Indirect / direct method; Outside of permanent location (P) | Internal procedure OP-W-01 based on EURAMET cg-15 v. 3 | |
| 16 | Calibrators Power supplies |
Calibration — AC voltage 10 Hz to 20 kHz — 1 mV to 100 mV · CMC 6 · 10⁻⁴ · U + 50 µV 10 Hz to 20 kHz — 0,1 V to 1 V · CMC 6 · 10⁻⁴ · U + 0,5 mV 10 Hz to 20 kHz — 1 V to 10 V · CMC 6 · 10⁻⁴ · U + 5 mV 10 Hz to 20 kHz — 10 V to 100 V · CMC 6 · 10⁻⁴ · U + 50 mV 10 Hz to 20 kHz — 100 V to 700 V · CMC 6 · 10⁻⁴ · U + 0,3 V 20 kHz to 50 kHz — 1 mV to 10 mV · CMC 6 · 10⁻⁴ · U + 60 µV 20 kHz to 50 kHz — 10 mV to 100 mV · CMC 1,4 · 10⁻³ · U + 55 µV 20 kHz to 50 kHz — 0,1 V to 1 V · CMC 2 · 10⁻³ · U + 0,55 mV 20 kHz to 50 kHz — 1 V to 10 V · CMC 2 · 10⁻³ · U + 5 mV 20 kHz to 50 kHz — 10 V to 100 V · CMC 2 · 10⁻³ · U + 50 mV 20 kHz to 50 kHz — 100 V to 700 V · CMC 2 · 10⁻³ · U + 0,3 V AC voltage |
Internal procedure; Direct method; Outside of permanent location (P) | Internal procedure OP-W-03 | |
| 17 | Oscilloscopes Scopemeters |
Calibration — AC voltage 1 k Hz to 10 MHz — 50 mV to 1 V · CMC 2% 10 MHz to 100 MHz — 50 mV to 1V · CMC 2,8 % 100 MHz to 600 MHz — 50 mV to 1 V · CMC 3,5 % 0,6 GHz to 1,0 GHz — 50 mV to 1 V · CMC 6,0 % 1,0 GHz to 3,6 GHz — 50 mV to 1 V · CMC 9% 3,6 GHz to 6,5 GHz — 50 mV to 1 V · CMC 11 % AC voltage |
Internal procedure; Direct method; At permanent location (S) | Internal procedure OP-W-08 based on EURAMET cg-7 v. 2.0 | |
| 18 | Oscilloscopes Scopemeters |
Calibration — AC voltage 10 Hz to 10 kHz; -internal AC source — 100 mV to 10 V · CMC 0,2 % AC voltage |
Internal procedure; Direct method; At permanent location (S) | Internal procedure OP-W-08 based on EURAMET cg-7 v. 2.0 | |
| 19 | Breakdown testers Electrical safety testers |
Calibration — AC voltage 50 Hz; 60 Hz — 50 V to 1000 V · CMC 1,5 ∙ 10⁻³ ∙ U + 0,5 V AC voltage |
Internal procedure; At permanent location (S) and outside of it (P) | Internal procedure OP-W-03 | |
| 20 | Digital ammeters Multimeters Power quality meters Residual current device testers Scopemeters (DMM) Leakage current meters |
Calibration — AC current 10 Hz to 40 Hz — 10 µA to 100 µA · CMC 5 · 10⁻⁴ · I + 15 nA 10 Hz to 40 Hz — 0,1 mA to 100 mA · CMC 3 · 10⁻⁴ · I + 0,1 µA 10 Hz to 40 Hz — 100 mA to 2 A · CMC 3 · 10⁻⁴ · I + 10 µA 50 Hz to 400 Hz — 11 A to 100 A · CMC 3 · 10⁻³ · I + 0,05 A 40 Hz to 1 kHz — 10 µA to 100 µA · CMC 1 · 10⁻⁴ · I + 10 nA 40 Hz to 1 kHz — 0,1 mA to 1 mA · CMC 1 · 10⁻⁴ · I + 50 nA 40 Hz to 1 kHz — 1 mA to 100 mA · CMC 1 · 10⁻⁴ · I + 1 µA 40 Hz to 1 kHz — 0,1 A to 2 A · CMC 2 · 10⁻⁴ · I + 0,2 mA 40 Hz to 1 kHz — 2 A to 11 A · CMC 0,06 % 1 kHz to 5 kHz — 10 µA to 100 µA · CMC 2,5 · 10⁻⁴ · I + 20 nA 1 kHz to 5 kHz — 0,1 mA to 1 mA · CMC 2 · 10⁻⁴ · I + 0,2 µA 1 kHz to 5 kHz — 1 mA to 100 mA · CMC 2 · 10⁻⁴ · I + 1,5 µA 1 kHz to 5 kHz — 0,1 A to 2 A · CMC 4 · 10⁻⁴ · I + 0,2 mA 1 kHz to 5 kHz — 2 A to 11 A · CMC 1 · 10⁻³ · I + 1 mA 5 kHz to 10 kHz — 10 µA to 100 µA · CMC 2 · 10⁻³ · I + 0,1 µA 5 kHz to 10 kHz — 0,1 mA to 1 mA · CMC 1 · 10⁻³ · I + 1 µA 5 kHz to 10 kHz — 1 mA to 100 mA · CMC 1 · 10⁻³ · I + 20 µA 5 kHz to 10 kHz — 0,1 A to 2 A · CMC 1 · 10⁻³ · I + 0,5 mA 5 kHz to 10 kHz — 2 A to 11 A · CMC 0,4 % AC current |
Internal procedure; Direct method; At permanent location (S) | Internal procedure OP-W-01 based on EURAMET cg-15 v. 3 | |
| 21 | Clamp meters | Calibration — AC current 50 Hz ;60 Hz — 0,01 A to 1 A · CMC 0,06 % 50 Hz ;60 Hz — 1 A to 10 A · CMC 0,16 % 50 Hz ;60 Hz — 10 A to 1000 A · CMC 0,43 % 400 Hz — 0,01 A to 1 A · CMC 0,06 % 400 Hz — 1 A to 10 A · CMC 0,16 % 400 Hz — 10 A to 100 A · CMC 0,43 % AC current |
Internal procedure; Direct method; At permanent location (S) | Internal procedure OP-W-01 | |
| 22 | Calibrators Generators |
Calibration — AC current 50 Hz to 400 Hz — 11 A to 100 A · CMC 5 · 10⁻⁴ · I + 0,05 A 10 Hz to 2 kHz — 1 µA to 200 µA · CMC 3 · 10⁻⁴ · I + 5 nA 10 Hz to 2 kHz — 0,2 mA to 200 mA · CMC 0,04 % 10 Hz to 2 kHz — 0,2 A to 2 A · CMC 3 · 10⁻⁴ · I + 0,1 mA 10 Hz to 2 kHz — 2 A to 20 A · CMC 8 · 10⁻⁴ · I + 1 mA 10 Hz to 2 kHz — 20 A to 30 A · CMC 1 · 10⁻³· I + 10 mA 2 kHz to 10 kHz — 1 µA to 200 µA · CMC 5 · 10⁻⁴ · I + 10 nA 2 kHz to 10 kHz — 0,2 mA to 200 mA · CMC 0,06 % 2 kHz to 10 kHz — 0,2 A to 2 A · CMC 5 · 10⁻⁴ · I + 0,2 mA 2 kHz to 10 kHz — 2 A to 20 A · CMC 0,1 % 2 kHz to 10 kHz — 20 A to 30 A · CMC 1,5 · 10⁻³ · I + 10 mA 10 kHz to 30 kHz — 1 µA to 200 µA · CMC 8 · 10⁻⁴ · I + 10 nA 10 kHz to 30 kHz — 0,2 mA to 200 mA · CMC 0,09 % 10 kHz to 30 kHz — 0,2 A to 2 A · CMC 8 · 10⁻⁴ · I + 2 mA AC current |
Internal procedure; Direct method; At permanent location (S) | Internal procedure OP-W-03 | |
| 23 | Power supplies | Calibration — AC current 1 Hz to 2 kHz — 1 µA to 100 µA · CMC 3 · 10⁻⁴ · I + 10 nA 1 Hz to 2 kHz — 0,1 mA to 100 mA · CMC 0,04 % 1 Hz to 2 kHz — 0,1 A to 2 A · CMC 3 · 10⁻⁴ · I + 0,2 mA 1 Hz to 2 kHz — 1 A to 18,5 A · CMC 0,1 % AC current |
Internal procedure; Direct method; At permanent location (S) | Internal procedure OP-W-03 | |
| 24 | Digital ammeters Multimeters Power quality meters Residual current device testers Scopemeters (DMM) Leakage current meter |
Calibration — AC current 50 Hz to 400 Hz — 11 A to 100 A · CMC 3 · 10⁻³ · I + 0,05 A 20 Hz to 1 kHz — 10 µA to 1 mA · CMC 1,5 · 10⁻³ · I + 50 nA 20 Hz to 1 kHz — 1 mA to 100 mA · CMC 0,1 % 20 Hz to 1 kHz — 0,1 A to 2 A · CMC 5 · 10⁻⁴ · I + 0,2 mA 20 Hz to 1 kHz — 2 A to 20 A · CMC 1,5 · 10⁻³ · I + 0,005 A 1 kHz to 5 kHz — 10 µA to 100 µA · CMC 3 · 10⁻³ · I + 0,3 µA 1 kHz to 5 kHz — 0,1 mA to 1 mA · CMC 3 · 10⁻³ · I + 1 µA 1 kHz to 5 kHz — 1 mA to 200 mA · CMC 3 · 10⁻³ · I + 0,1 mA 5 kHz to 10 kHz — 0,2 mA to 10 mA · CMC 7 · 10⁻³ · I + 2 µA 5 kHz to 10 kHz — 10 mA to 200 mA · CMC 5 · 10⁻³ · I + 0,2 mA AC current |
Internal procedure; Direct method; Outside of permanent location (P) | Internal procedure OP-W-01 based on EURAMET cg-15 v. 3 | |
| 25 | Clamp meters | Calibration — AC current 50 Hz ;60 Hz — 0,01 A to 1 A · CMC 0,1 % 50 Hz ;60 Hz — 1 A to 10 A · CMC 0,25 % 50 Hz ;60 Hz — 10 A to 1000 A · CMC 0,5 % 400 Hz — 0,01 A to 1 A · CMC 0,1 % 400 Hz — 1 A to 10 A · CMC 0,25 % 400 Hz — 10 A to 100 A · CMC 0,5 % AC current |
Internal procedure; Direct method; Outside of permanent location (P) | Internal procedure OP-W-01 | |
| 26 | Calibrators Generators |
Calibration — AC current 50 Hz to 400 Hz — 11 A to 100 A · CMC 5 · 10⁻⁴ · I + 0,05 A 10 Hz to 2 kHz — 1 µA to 100 µA · CMC 8 · 10⁻⁴ · I + 0,35 µA 10 Hz to 2 kHz — 0,1 mA to 10 mA · CMC 1,2 · 10⁻³ · I + 0,5 µA 10 Hz to 2 kHz — 10 mA to 100 mA · CMC 1,2 · 10⁻³ · I + 20 µA 10 Hz to 2 kHz — 0,1 A to 1 A · CMC 2 · 10⁻³ · I + 1 mA 10 Hz to 2 kHz — 1 A to 3 A · CMC 2 · 10⁻³ · I + 3 mA 10 Hz to 2 kHz — 3 A to 10 A · CMC 1,5 · 10⁻³ · I + 10 mA 10 Hz to 2 kHz — 10 A to 30 A · CMC 1 · 10⁻³ · I + 10 mA 2 kHz to 5 kHz — 1 µA to 100 µA · CMC 8 · 10⁻⁴ · I + 0,35 µA 2 kHz to 5 kHz — 0,1 mA to 10 mA · CMC 1,2 · 10⁻³ · I + 0,5 µA 2 kHz to 5 kHz — 10 mA to 100 mA · CMC 1,2 · 10⁻³ · I + 20 uA 2 kHz to 5 kHz — 0,1 A to 1 A · CMC 9 · 10⁻³ · I + 1 mA 2 kHz to 5 kHz — 1 A to 3 A · CMC 9 · 10⁻³ · I + 3 mA 2 kHz to 5 kHz — 3 A to 10 A · CMC 1,5 · 10⁻³ · I + 10 mA AC current |
Internal procedure; Direct method; Outside of permanent location (P) | Internal procedure OP-W-03 | |
| 27 | Power supplies | Calibration — AC current 10 to 400 Hz — 0,1 mA to 10 mA · CMC 1,2 · 10⁻³ · I + 0,5 µA 10 to 400 Hz — 10 mA to 100 mA · CMC 1,2 · 10⁻³ · I + 20 µA 10 to 400 Hz — 0,1 A to 1 A · CMC 2 · 10⁻³ · I + 1 mA 10 to 400 Hz — 1 A to 3 A · CMC 2 · 10⁻³ · I + 3 mA 10 to 400 Hz — 3 A to 10 A · CMC 1,5 · 10⁻³ · I + 10 mA 10 to 400 Hz — 10 A to 18,5 A · CMC 1 · 10⁻³ · I + 10 mA AC current |
Internal procedure; Direct method; Outside of permanent location (P) | Internal procedure OP-W-03 | |
| 28 | Digital ohmmeters Multimeters Continuity testers Power network parameter meters Scopemeters (DMM) |
Calibration — DC resistance 100 µΩ · CMC 0,1 % 1 mΩ to 100 mΩ · CMC 0,01 % 0,1 Ω to 100 MΩ · CMC 0,005 % DC resistance |
Internal procedure; Direct method; At permanent location (S) | Internal procedure OP-W-01 based on EURAMET cg-15 v. 3 | |
| 29 | Insulation resistance meters Power network parameter meters Power quality meters |
Calibration — DC resistance Test voltage up to 500 V — 50 kΩ to 1000 kΩ · CMC 0,2 % Test voltage up to 2,5 kV — 1 MΩ to 10 MΩ · CMC 0,2 % Test voltage up to 5 kV — 10 MΩ to 100 MΩ · CMC 0,2 % Test voltage up to 5 kV — 100 MΩ to 1000 MΩ · CMC 0,3 % Test voltage up to 5 kV — 1 GΩ to 10 GΩ · CMC 0,7 % Test voltage up to 5 kV — 10 GΩ to 100 GΩ · CMC 1,2 % Test voltage up to 5 kV — 100 GΩ to 5000 GΩ · CMC 2,0 % DC resistance |
Internal procedure; Direct method; At permanent location (S) | Internal procedure OP-W-01 | |
| 30 | Shunts Fixed resistors Variable resistors |
Calibration — DC resistance 100 µΩ · CMC 0,2 µΩ 0,001 Ω to 0,01 Ω · CMC 0,01 % 0,01 Ω to 0,1 Ω · CMC 0,02 % 0,1 Ω to 10 Ω · CMC 0,005 % 10 Ω to 1 MΩ · CMC 0,001 % 1 MΩ to 10 MΩ · CMC 0,005 % 10 MΩ to 100 MΩ · CMC 0,01 % 100 MΩ to 1 GΩ · CMC 0,1 % 1 GΩ to 20 GΩ · CMC 0,2 % DC resistance |
Internal procedure; Direct / indirect method; At permanent location (S) | Internal procedure OP-W-02 | |
| 31 | Resistance calibrators | Calibration — DC resistance 100 µΩ · CMC 0,2 µΩ 0,001 Ω to 0,01 Ω · CMC 0,01 % 0,01 Ω to 0,1 Ω · CMC 0,02 % 0,1 Ω to 10 Ω · CMC 0,005 % 10 Ω to 1 MΩ · CMC 0,001 % 1 MΩ to 10 MΩ · CMC 0,005 % 10 MΩ to 100 MΩ · CMC 0,01 % 100 MΩ to 1 GΩ · CMC 0,1 % 1 GΩ to 20 GΩ · CMC 0,2 % DC resistance |
Internal procedure; Direct / indirect method; At permanent location (S) | Internal procedure OP-W-03 | |
| 32 | Oscilloscopes Scopemeters |
Calibration — DC resistance 10 Ω to 100 Ω · CMC 0,15 % 0,1 MΩ to 20 MΩ · CMC 0,1 % DC resistance |
Internal procedure; Direct method; At permanent location (S) | Internal procedure OP-W-08 based on EURAMET cg-7 v.2.0 | |
| 33 | Digital ohmmeters Multimeters Continuity testers Power network parameter meters Scopemeters (DMM) |
Calibration — DC resistance 50 mΩ to 300 mΩ · CMC 0,05 % 0,3 Ω to 10 MΩ · CMC 0,05 % 10 MΩ to 100 MΩ · CMC 0,1 % DC resistance |
Internal procedure; Direct method; Outside of permanent location (P) | Internal procedure OP-W-01 based on EURAMET cg-15 v. 3 | |
| 34 | Insulation resistance meters Power network parameter meters Power quality meters |
Calibration — DC resistance Test voltage up to 500 V — 50 kΩ to 1000 kΩ · CMC 0,5 % Test voltage up to 2,5 kV — 1 MΩ to 10 MΩ · CMC 0,5 % Test voltage up to 5 kV — 10 MΩ to 1000 MΩ · CMC 0,5 % Test voltage up to 5 kV — 1 GΩ to 10 GΩ · CMC 1% Test voltage up to 5 kV — 10 GΩ to 100 GΩ · CMC 1,5 % DC resistance |
Internal procedure; Direct method; Outside of permanent location (P) | Internal procedure OP-W-01 | |
| 35 | Shunts Fixed resistors Variable resistors |
Calibration — DC resistance 100 µΩ · CMC 0,2 µΩ 0,001 Ω to 0,01 Ω · CMC 0,1 % 0,01 Ω to 0,1 Ω · CMC 0,02 % 0,1 Ω to 10 Ω · CMC 1 · 10⁻⁴ · R + 50 µΩ 10 Ω to 1 MΩ · CMC 0,01 % 1 MΩ to 100 MΩ · CMC 0,05 % 100 MΩ to 1 GΩ · CMC 0,1 % DC resistance |
Internal procedure; Direct / indirect method; Outside of permanent location (P) | Internal procedure OP-W-02 | |
| 36 | Resistance calibrators | Calibration — DC resistance 100 µΩ · CMC 0,2 µΩ 0,001 Ω to 0,01 Ω · CMC 0,1 % 0,01 Ω to 0,1 Ω · CMC 0,02 % 0,1 Ω to 10 Ω · CMC 1 · 10⁻⁴ · R + 50 µΩ 10 Ω to 1 MΩ · CMC 0,01 % 1 MΩ to 100 MΩ · CMC 0,05 % 100 MΩ to 1 GΩ · CMC 0,1 % DC resistance |
Internal procedure; Direct / indirect method; Outside of permanent location (P) | Internal procedure OP-W-03 | |
| 37 | Digital ohmmeters Power network parameter meters Electrical safety testers |
Calibration — AC resistance f = 50 Hz — 0,1 Ω to 0,4 Ω · CMC 0,7 % f = 50 Hz — 0,4 Ω to 3 Ω · CMC 0,6 % f = 50 Hz — 3 Ω to 20 kΩ · CMC 0,15 % AC resistance |
Internal procedure; Direct method; At permanent location (S) and outside of it (P) | Internal procedure OP-W-01 | |
| 38 | Fault loop impedance meters Residual current device testers |
Calibration — AC resistance f = 50 Hz — 100 mΩ to 250 mΩ · CMC 0,6 % f = 50 Hz — 250 mΩ to 1000 mΩ · CMC 0,3 % f = 50 Hz — 1000 mΩ to 2000 mΩ · CMC 0,12 % f = 50 Hz — 2 Ω to 19 Ω · CMC 0,3 % f = 50 Hz — 19 Ω to 2 kΩ · CMC 0,1 % AC resistance |
Internal procedure; Direct method; At permanent location (S) and outside of it (P) | Internal procedure OP-W-01 | |
| 39 | Earth resistance meters | Calibration — AC resistance 50 Hz to 125 Hz — 0,1 Ω to 0,4 Ω · CMC 0,7 % 50 Hz to 125 Hz — 0,4 Ω to 3 Ω · CMC 0,6 % 50 Hz to 125 Hz — 3 Ω to 20 kΩ · CMC 0,15 % AC resistance |
Internal procedure; Direct method; At permanent location (S) and outside of it (P) | Internal procedure OP-W-01 | |
| 40 | Earth continuity testers | Calibration — AC resistance 50 Hz to 60 Hz — 100 mΩ to 250 mΩ · CMC 0,6 % 50 Hz to 60 Hz — 250 mΩ to 1000 mΩ · CMC 0,3 % 50 Hz to 60 Hz — 1000 mΩ to 2000 mΩ · CMC 0,12 % 50 Hz to 60 Hz — 2 Ω to 19 Ω · CMC 0,3 % 50 Hz to 60 Hz — 19 Ω to 2 kΩ · CMC 0,1 % AC resistance |
Internal procedure; Direct method; At permanent location (S) and outside of it (P) | Internal procedure OP-W-01 | |
| 41 | Power network parameter meters | Calibration — Phase angle 50 Hz; 10 V to 280 V; 0,1 A to 1000 A — 0° to 360° · CMC 0,2° 50 Hz; 10 V to 280 V; 0,1 A to 1000 A — cosφ ±<1 to 0,5> · CMC 0,0028 50 Hz; 280 V to 1000 V; 0,1 A to 1000 A — 0° to 360° · CMC 0,6° 50 Hz; 280 V to 1000 V; 0,1 A to 1000 A — cosφ ±<1 to 0,5> · CMC 0,0088 Phase angle |
Internal procedure; Direct method; At permanent location (S) and outside of it (P) | Internal procedure OP-W-01 based on EURAMET cg 15 v.3.0 | |
| 42 | Power meters Power quality meters Power network parameter meters |
Calibration — DC power 10 V to 1000 V; 0,1 A to 20 A — 1 W to 20 kW · CMC 0,05 % DC power |
Internal procedure; Direct method; At permanent location (S) and outside of it (P) | Internal procedure OP-W-01 based on EURAMET cg-15 v. 3.0 | |
| 43 | Power meters Power quality meters Power network parameter meters |
Calibration — DC power 10 V to 1000 V; 10 A to 1000 A — 100 W to 1 MW · CMC 0,40 % DC power |
Internal procedure; Direct method. Clamp measurement; At permanent location (S) and outside of it (P) | Internal procedure OP-W-01 based on EURAMET cg-15 v. 3.0 | |
| 44 | Digital single-phase active power meters Digital three-phase active power meters Digital single-phase apparent power meters Digital three-phase apparent power meters Digital single-phase reactive power meters Digital three-phase reactive power meters Power quality meters Power network parameter meters |
Calibration — AC power 50 Hz; 10 V to 1000 V; 0,1 A to 20 A; cosφ / sinφ ±1 — 1 W to 20 kW · CMC 0,13 % 50 Hz; 10 V to 1000 V; 0,1 A to 20 A; cosφ / sinφ ±1 — 1 VA to 20 kVA · CMC 0,13 % 50 Hz; 10 V to 1000 V; 0,1 A to 20 A; cosφ / sinφ ±1 — 1 var to 20 kvar · CMC 0,13 % 50 Hz; 10 V to 1000 V; 0,1 A to 20 A; inductive or capacitive cosφ and sinφ; cosφ ± (1 to 0,5>; sinφ ± (1 to 0,5> — 0,5 W to 10 kW · CMC 0,48 % 50 Hz; 10 V to 1000 V; 0,1 A to 20 A; inductive or capacitive cosφ and sinφ; cosφ ± (1 to 0,5>; sinφ ± (1 to 0,5> — 1 VA to 20 kVA · CMC 0,13 % 50 Hz; 10 V to 1000 V; 0,1 A to 20 A; inductive or capacitive cosφ and sinφ; cosφ ± (1 to 0,5>; sinφ ± (1 to 0,5> — 0,5 var to 10 kvar · CMC 0,48 % AC power |
Internal procedure; Direct method. Three-phase measurement performed phase by phase; At permanent location (S) and outside of it (P) | Internal procedure OP-W-01 based on EURAMET cg-15 v. 3.0 | |
| 45 | Digital single-phase active power meters Digital three-phase active power meters Digital single-phase apparent power meters Digital three-phase apparent power meters Digital single-phase reactive power meters Digital three-phase reactive power meters Power quality meters Power network parameter meters |
Calibration — AC power 50 Hz; 10 V to 1000 V; 10 A to 1000 A; cosφ / sinφ ±1 — 100 W to 1 MW · CMC 0,45 % 50 Hz; 10 V to 1000 V; 10 A to 1000 A; cosφ / sinφ ±1 — 100 VA to 1 MVA · CMC 0,45 % 50 Hz; 10 V to 1000 V; 10 A to 1000 A; cosφ / sinφ ±1 — 100 var to 1 Mvar · CMC 0,45 % 50 Hz; 10 V to 1000 V; 10 A to 1000 A; inductive or capacitive cosφ and sinφ; cosφ ± (1 to 0,5>; sinφ ± (1 to 0,5> — 50 W to 0,5 MW · CMC 0,65 % 50 Hz; 10 V to 1000 V; 10 A to 1000 A; inductive or capacitive cosφ and sinφ; cosφ ± (1 to 0,5>; sinφ ± (1 to 0,5> — 100 VA to 1 MVA · CMC 0,45 % 50 Hz; 10 V to 1000 V; 10 A to 1000 A; inductive or capacitive cosφ and sinφ; cosφ ± (1 to 0,5>; sinφ ± (1 to 0,5> — 50 var to 0,5 Mvar · CMC 0,65 % AC power |
Internal procedure; Direct method. Clamp measurement. Three-phase measurement performed phase by phase; At permanent location (S) and outside of it (P) | Internal procedure OP-W-01 based on EURAMET cg-15 v. 3.0 | |
| 46 | Breakdown testers Electrical safety testers Voltage sources |
Calibration — High voltage and current DC voltage — 1 kV to 10 kV · CMC 0,05 % DC voltage — 10 kV to 35 kV · CMC 0,1 % AC voltage at 50 Hz; 60 Hz — 1 kV to 10 kV · CMC 0,15 % AC voltage at 50 Hz; 60 Hz — 10 kV to 30 kV · CMC 0,2 % High voltage and current |
Internal procedure; At permanent location (S) and outside of it (P) | Internal procedure OP-W-03 | |
| 47 | Temperature simulators (resistance) | Calibration — Electrical simulation of quantities -200 oC to 250 oC · CMC 0,007 oC 250 oC to 850 oC · CMC 0,015 oC Electrical simulation of quantities |
Internal procedure; Indirect method; At permanent location (S) | Internal procedure OP-W-03 based on EURAMET cg-11 v. 2 | |
| 48 | Temperature indicators (meters) for use with resistance sensors | Calibration — Electrical simulation of quantities -200 oC to 250 oC · CMC 0,007 oC 250 oC to 850 oC · CMC 0,015 oC Electrical simulation of quantities |
Internal procedure; Indirect method; At permanent location (S) | Internal procedure OP-W-01 based on EURAMET cg-11 v. 2 | |
| 49 | Temperature simulators (resistance) | Calibration — Electrical simulation of quantities -200 °C to 850 °C · CMC 0,06 °C Electrical simulation of quantities |
Internal procedure; Indirect method; Outside of permanent location (P) | Internal procedure OP-W-03 based on EURAMET cg-11 v. 2 | |
| 50 | Temperature indicators (meters) for use with resistance sensors | Calibration — Electrical simulation of quantities -200 °C to 850 °C · CMC 0,06 °C Electrical simulation of quantities |
Internal procedure; Indirect method; Outside of permanent location (P) | Internal procedure OP-W-01 based on EURAMET cg-11 v. 2 | |
| 51 | Oscilloscopes Scopemeters |
Calibration — Time (time interval) 10 ns to 10 s · CMC 1 ∙ 10⁻⁶ ∙ t + 1,5 ns Time (time interval) |
Internal procedure; Direct method; At permanent location (S) | Internal procedure OP-W-08 based on EURAMET cg-7 v. 2.0 | |
| 52 | Multimeters Digital frequency meters Power network parameter meters |
Calibration — Frequency Square-wave signal — 1 Hz to 10 Hz · CMC 3 · 10⁻⁸ · f Square-wave signal — 10 Hz to 50 MHz · CMC 3 · 10⁻⁹ · f Sine-wave signal — 1 Hz to 10 Hz · CMC 1 · 10⁻⁴ · f + 0,001 Hz Sine-wave signal — 10 Hz to 100 Hz · CMC 1 · 10⁻⁵ · f + 0,001 Hz Sine-wave signal — 100 Hz to 1 kHz · CMC 1 · 10⁻⁶ · f + 0,001 Hz Sine-wave signal — 1 kHz to 10 kHz · CMC 1 · 10⁻⁷ · f + 0,001 Hz Sine-wave signal — 10 kHz to 350 kHz · CMC 2 · 10⁻⁸ · f Sine-wave signal — 350 kHz to 5 GHz · CMC 3 · 10⁻⁹ · f Frequency |
Internal procedure; Direct method; At permanent location (S) | Internal procedure OP-W-07 | |
| 53 | Frequency generators Calibrators |
Calibration — Frequency Square-wave signal — 1 Hz to 10 Hz · CMC 3 · 10⁻⁸ · f Square-wave signal — 10 Hz to 500 MHz · CMC 3 · 10⁻⁹ · f Sine-wave signal — 1 Hz to 10 Hz · CMC 1 · 10⁻⁴ · f + 0,001 Hz Sine-wave signal — 10 Hz to 100 Hz · CMC 1 · 10⁻⁵ · f + 0,001 Hz Sine-wave signal — 100 Hz to 1 kHz · CMC 1 · 10⁻⁶ · f + 0,001 Hz Sine-wave signal — 1 kHz to 10 kHz · CMC 1 · 10⁻⁷ · f + 0,001 Hz Sine-wave signal — 10 kHz to 350 kHz · CMC 2 · 10⁻⁸ · f Sine-wave signal — 350 kHz to 5 GHz · CMC 3 · 10⁻⁹ · f Frequency |
Internal procedure; Direct method; At permanent location (S) | Internal procedure OP-W-07 | |
| 54 | Oscilloscopes Scopemeters |
Calibration — Frequency - internal AC source — 10 Hz to 100 kHz · CMC 1 ∙ 10⁻⁶ ∙ f + 0,001 Hz Frequency |
Internal procedure; Direct method; At permanent location (S) | Internal procedure OP-W-08 | |
| 55 | Multimeters Digital frequency meters Power network parameter meters |
Calibration — Frequency Square-wave signal — 1 Hz to 10 Hz · CMC 3 · 10⁻⁵ · f + 0,01 Hz Square-wave signal — 10 Hz to 50 MHz · CMC 3 · 10⁻⁶ · f Sine-wave signal — 1 Hz to 10 Hz · CMC 5 · 10⁻² · f + 0,01 Hz Sine-wave signal — 10 Hz to 100 Hz · CMC 1 · 10⁻² · f + 0,01 Hz Sine-wave signal — 100 Hz to 1 kHz · CMC 1 · 10⁻³ · f + 0,01 Hz Sine-wave signal — 1 kHz to 10 kHz · CMC 1 · 10⁻⁴ · f + 0,01 Hz Sine-wave signal — 10 kHz to 350 kHz · CMC 3 · 10⁻⁵ · f Sine-wave signal — 350 kHz to 160 MHz · CMC 3 · 10⁻⁶ · f Frequency |
Internal procedure; Direct method; Outside of permanent location (P) | Internal procedure OP-W-07 | |
| 56 | Frequency generators Calibrators |
Calibration — Frequency Square-wave signal — 1 Hz to 10 Hz · CMC 3 · 10⁻⁵ · f + 0,01 Hz Square-wave signal — 10 Hz to 200 MHz · CMC 3 · 10⁻⁶ · f Sine-wave signal — 1 Hz to 10 Hz · CMC 5 · 10⁻² · f + 0,01 Hz Sine-wave signal — 10 Hz to 100 Hz · CMC 1 · 10⁻² · f + 0,01 Hz Sine-wave signal — 100 Hz to 1 kHz · CMC 1 · 10⁻³ · f + 0,01 Hz Sine-wave signal — 1 kHz to 10 kHz · CMC 1 · 10⁻⁴ · f + 0,01 Hz Sine-wave signal — 10 kHz to 350 kHz · CMC 3 · 10⁻⁵ · f Sine-wave signal — 350 kHz to 200 MHz · CMC 3 · 10⁻⁶ · f Frequency |
Internal procedure; Direct method; Outside of permanent location (P) | Internal procedure OP-W-07 | |
| 57 | Thermohygrometers | Calibration — Relative humidity 10 °C to 30 °C; 10 %rh to 90 %rh — 10 % rh · CMC 1,1 %rh 10 °C to 30 °C; 10 %rh to 90 %rh — 90 %rh · CMC 1,6 %rh 30 °C to 50 °C; 10 %rh to 90 %rh — 10 % rh · CMC 1,1 %rh 30 °C to 50 °C; 10 %rh to 90 %rh — 90 %rh · CMC 2,1 %rh 50 °C to 60 °C; 10 %rh to 90 %rh — 10 % rh · CMC 2,2 %rh 50 °C to 60 °C; 10 %rh to 90 %rh — 90 %rh · CMC 2,5 %rh Relative humidity |
Internal procedure; Direct method; At permanent location (S) | Internal procedure OP-W-05-01 | |
| 58 | Thermohygrometers | Calibration — Relative humidity 10 °C to 20 °C; 25 %rh to 90 %rh — 25 % rh · CMC 1,2 %rh 10 °C to 20 °C; 25 %rh to 90 %rh — 90 %rh · CMC 2,0 %rh 20 °C to 30 °C; 15 %rh to 90 %rh — 15 % rh · CMC 1,1 %rh 20 °C to 30 °C; 15 %rh to 90 %rh — 90 %rh · CMC 1,9 %rh 30 °C to 50 °C; 10 %rh to 90 %rh — 10 %rh · CMC 1,6 %rh 30 °C to 50 °C; 10 %rh to 90 %rh — 90 %rh · CMC 2,2 %rh Relative humidity |
Internal procedure; Direct method; Outside of permanent location (P) | Internal procedure OP-W-05-01 | |
| 59 | Electronic pressure gauges Bourdon tube pressure gauges |
Calibration — Pressure - gauge pressure (gas) — -100 kPa to -5 kPa · CMC 0,010 kPa - gauge pressure (gas) — -5 kPa to 5 kPa · CMC 0,058 kPa - gauge pressure (gas) — 5 kPa to 100 kPa · CMC 0,010 kPa - gauge pressure (gas) — 100 kPa to 200 kPa · CMC 0,058 kPa - gauge pressure (gas) — 200 kPa to 600 kPa · CMC 1,0 kPa - gauge pressure (gas) — 600 kPa to 1000 kPa · CMC 0,071 kPa - gauge pressure (gas) — 1000 kPa to 12000 kPa · CMC 0,0071 % Pressure |
Internal procedure; Method 5.2.3. Direct method; At permanent location (S) | Internal procedure OP-W-06-01 based on EURAMET cg-17 v.4.1 | |
| 60 | Electronic pressure gauges Bourdon tube pressure gauges |
Calibration — Pressure - gauge pressure (liquid) — -100 kPa to 200 kPa · CMC 0,058 kPa - gauge pressure (liquid) — 200 kPa to 600 kPa · CMC 1,0 kPa - gauge pressure (liquid) — 600 kPa to 1000 kPa · CMC 0,082 kPa - gauge pressure (liquid) — 1000 kPa to 7000 kPa · CMC 0,0082 % - gauge pressure (liquid) — 7000 kPa to 70000 kPa · CMC 0,0074 % Pressure |
Internal procedure; Method 5.2.3. Direct method; At permanent location (S) | Internal procedure OP-W-06-01 based on EURAMET cg-17 v.4.1 | |
| 61 | Electronic pressure gauges Bourdon tube pressure gauges |
Calibration — Pressure - differential pressure (gas) — -10 kPa to -1 kPa · CMC 0,012 kPa - differential pressure (gas) — -1 kPa to 1 kPa · CMC 0,0012 kPa - differential pressure (gas) — 1 kPa to 10 kPa · CMC 0,012 kPa Pressure |
Internal procedure; Method 5.2.3. Direct method; At permanent location (S) | Internal procedure OP-W-06-01 based on EURAMET cg-17 v.4.1 | |
| 62 | Electronic pressure gauges Bourdon tube pressure gauges |
Calibration — Pressure - gauge pressure (gas) — -100 kPa to -10 kPa · CMC 0,058 kPa - gauge pressure (gas) — -10 kPa to -1 kPa · CMC 0,012 kPa - gauge pressure (gas) — -1 kPa to 1 kPa · CMC 0,0012 kPa - gauge pressure (gas) — 1 kPa to 10 kPa · CMC 0,012 kPa - gauge pressure (gas) — 10 kPa to 200 kPa · CMC 0,058 kPa - gauge pressure (gas) — 200 kPa to 3500 kPa · CMC 1,0 kPa - gauge pressure (gas) — 3500 kPa to 6000 kPa · CMC 10 kPa Pressure |
Internal procedure; Method 5.2.3. Direct method; Outside of permanent location (P) | Internal procedure OP-W-06-01 based on EURAMET cg-17 v.4.1 | |
| 63 | Electrical thermometers (including electronic) Electrical thermometers (with temperature recording) |
Calibration — Temperature (electrical thermometry) -35 °C do 0 °C · CMC 0,05 °C 0 °C · CMC 0,03 °C 0 °C do 80 °C · CMC 0,06 °C 80 °C do 155 °C · CMC 0,07 °C 155 °C do 180 °C · CMC 0,08 °C 180 °C to 300 °C · CMC 0,14 °C 300 °C do 400 °C · CMC 0,52 °C Temperature (electrical thermometry) |
Internal procedure; Direct method; At permanent location (S) | Internal procedure OP-W-04-01 | |
| 64 | Electrical thermometers (including electronic) Electrical thermometers (with temperature recording) |
Calibration — Temperature (electrical thermometry) -35 °C to 100 °C · CMC 0,07 °C 100 °C to 150 °C · CMC 0,18 °C 150 °C to 180 °C · CMC 0,30 °C 180 °C to 200 °C · CMC 0,34 °C 200 °C to 250 °C · CMC 0,44 °C 250 °C to 300 °C · CMC 0,51 °C 300 °C to 350 °C · CMC 0,64 °C 350 °C to 400 °C · CMC 0,70 °C Temperature (electrical thermometry) |
Internal procedure; Direct method; Outside of permanent location (P) | Internal procedure OP-W-04-01 | |
| 65 | Electrical thermometers (including electronic) Electrical thermometers (with temperature recording) |
Calibration — Temperature (electrical thermometry) -5 °C to 0 °C · CMC 0,37 °C 0 °C to 10 °C · CMC 0,27 °C 0 °C to 15 °C · CMC 0,21 °C 15 °C to 45 °C · CMC 0,14 °C 45 °C to 50 °C · CMC 0,21 °C 45 °C to 60 °C · CMC 0,28 °C Temperature (electrical thermometry) |
Internal procedure; Calibration in a climatic chamber. Direct method; At permanent location (S) | Internal procedure OP-W-04-01 | |
Reference standards (15)
EURAMET cg 15 v.3.0
EURAMET cg-11 v. 2
EURAMET cg-15 v. 3
EURAMET cg-15 v. 3.0
EURAMET cg-17 v.4.1
EURAMET cg-7 v. 2.0
EURAMET cg-7 v.2.0
OP-W-01
OP-W-02
OP-W-03
OP-W-04-01
OP-W-05-01
OP-W-06-01
OP-W-07
OP-W-08