🇵🇱 THERMOCONTROL Sp. z o.o. PL
Metrology & calibration
THERMOCONTROL Sp. z o.o. is a calibration laboratory accredited by PCA under number AP 208 (Krosno, Poland). Its accreditation scope covers 5 calibration items in the following areas: Metrology & calibration. Calibrated items include: Temperature indicators including temperature controllers, Temperature recorders, Temperature simulators, Furnaces. Most frequently used calibration principles: Direct method; At permanent location (S) and outside of it (P), Electric indirect method; At permanent location (S) and outside of…, Direct method; Outside of permanent location (P).
At a glance
- Accreditation number: PCA AP 208
- Calibration items in scope: 5
- Types of calibrated items: 8
- Calibration principles used: 3
- City: Krosno, Poland
- Valid until: 22-06-2030
- Accreditation number
- AP 208
- Accreditation body
- PCA
- Address
- ul. Gen. Leopolda Okulickiego 1A/9, 38-400 Krosno
- City
- Krosno, Poland
- Division
- Laboratorium Wzorcujące THERMOCONTROL
- Valid until
- 22-06-2030
What this laboratory calibrates (8)
- Temperature indicators including temperature controllers — 2 calibration items
- Temperature recorders — 2 calibration items
- Temperature simulators — 2 calibration items
- Furnaces — 1 calibration item
- Liquid thermostats — 1 calibration item
- Temperature indicators (meters) compatible with resistance sensors — 1 calibration item
- Temperature indicators (meters) compatible with thermoelectric sensors — 1 calibration item
- Thermostatic chambers — 1 calibration item
Calibration principles (3)
- Direct method; At permanent location (S) and outside of it (P) — 2 calibration items
- Electric indirect method; At permanent location (S) and outside of it (P) — 2 calibration items
- Direct method; Outside of permanent location (P) — 1 calibration item
Certificate information
- Issue date
- 27.05.2026
- Issue no.
- 7
- Certificate date
- 23.06.2022
- Accreditation cycle
- 27.05.2026 — 22.06.2030
- Approved by
- Katarzyna Wiśniewska
Accreditation scope — calibration items (5)
| No. | Calibrated quantity / subject of calibration | Nominal range / parameters / CMC | Calibration principle | Calibration procedure | |
|---|---|---|---|---|---|
| Calibration items | |||||
| 1 | Temperature simulators Temperature indicators (meters) compatible with thermoelectric sensors Temperature indicators including temperature controllers Temperature recorders |
Calibration — Electric quantity simulation -100 °C to 1820 °C · CMC 0,5 °C Electric quantity simulation |
Electric indirect method; At permanent location (S) and outside of it (P) | EURAMET cg-11 v.2.0 | |
| 2 | Temperature simulators Temperature indicators (meters) compatible with resistance sensors Temperature indicators including temperature controllers Temperature recorders |
Calibration — Electric quantity simulation -100 °C to 850 °C · CMC 0,2 °C Electric quantity simulation |
Electric indirect method; At permanent location (S) and outside of it (P) | EURAMET cg-11 v.2.0 | |
| 3 | Thermostatic chambers | Calibration — Temperature (electric thermometry) -80 °C to 300 °C · CMC 2,5 °C Temperature (electric thermometry) |
Direct method; At permanent location (S) and outside of it (P) | EURAMET cg-20 v.5.0 | |
| 4 | Furnaces | Calibration — Temperature (electric thermometry) 30 °C to 400 °C · CMC 2,5 °C 400 °C to 1200 °C · CMC 2,6 °C 1200 °C to 1330 °C · CMC 2,8 °C Temperature (electric thermometry) |
Direct method; At permanent location (S) and outside of it (P) | EURAMET cg-20 v.5.0 | |
| 5 | Liquid thermostats | Calibration — Temperature (electric thermometry) 0 °C to 140 °C · CMC 2,5 °C Temperature (electric thermometry) |
Direct method; Outside of permanent location (P) | EURAMET cg-20 v.5.0 | |
Reference standards (2)
EURAMET cg-11 v.2.0