🇵🇱 Agencja ANTICORR Gdańsk Sp. z o.o. PL

PCA AP 204 • Gdańsk, Poland • 4 calibration items

Metrology & calibration

Agencja ANTICORR Gdańsk Sp. z o.o. is a calibration laboratory accredited by PCA under number AP 204 (Gdańsk, Poland). Its accreditation scope covers 4 calibration items in the following areas: Metrology & calibration. Calibrated items include: Coating thickness gauges, Electrical thermometers (including electronic), Reference foils, Thermohygrometers. Most frequently used calibration principles: Internal procedure; At permanent location (S), Internal procedure; Direct method using a digital indicator; At per…, Internal procedure; Direct method using reference foils; At permane….

At a glance

  • Accreditation number: PCA AP 204
  • Calibration items in scope: 4
  • Types of calibrated items: 4
  • Calibration principles used: 4
  • City: Gdańsk, Poland
  • Valid until: 30-03-2030
Accreditation number
AP 204
Accreditation body
PCA
Address
ul. Tarcice 11, 80-718 Gdańsk
City
Gdańsk, Poland
Valid until
30-03-2030

What this laboratory calibrates (4)

Calibration principles (4)

Certificate information

Issue date
04.03.2026
Issue no.
4
Certificate date
31.03.2022
Accreditation cycle
04.03.2026 — 30.03.2030
Approved by
Katarzyna Wiśniewska

Accreditation scope — calibration items (4)

The uncertainty covered by the CMC is the expanded uncertainty with a coverage probability of approximately 95 % and is expressed in measurand units. The CMC uncertainty expressed as a percentage is the relative measurement uncertainty and refers to the percentage share in the value of the measurand.

No. Calibrated quantity / subject of calibration Nominal range / parameters / CMC Calibration principle Calibration procedure
Calibration items
1 Coating thickness gauges Calibration — Length
0 µm to 250 µm · CMC 2,5 µm 250 µm to 600 µm · CMC 2,8 µm 600 µm to 1000 µm · CMC 3,4 µm 1000 µm to 3000 µm · CMC 5,3 µm 3000 µm to 4000 µm · CMC 7,0 µm 4000 µm to 5000 µm · CMC 9,0 µm 5000 µm to 6000 µm · CMC 10,5 µm
Length
Internal procedure; Direct method using reference foils; At permanent location (S) KMW-01
2 Reference foils Calibration — Length
0 µm to 250 µm · CMC 3,5 µm 250 µm to 500 µm · CMC 3,6 µm 500 µm to 800 µm · CMC 3,7 µm 800 µm to 1200 µm · CMC 3,8 µm
Length
Internal procedure; Direct method using a digital indicator; At permanent location (S) KMW-03
3 Thermohygrometers Calibration — Relative humidity
in the temperature range 10 °C to 20 °C — 50 %rh to 75 %rh · CMC 2,5 %rh in the temperature range 20 °C to 40 °C — 20 %rh to 80 %rh · CMC 2,5 %rh in the temperature range 40 °C — 20 %rh to 50 %rh · CMC 2,5 %rh
Relative humidity
Internal procedure; At permanent location (S) KMW-02
4 Electrical thermometers (including electronic) Calibration — Temperature (electrical thermometry)
10 °C to 40 °C · CMC 0,7 °C
Temperature (electrical thermometry)
Internal procedure; Direct method. Calibration in a thermostatic chamber; At permanent location (S) KMW-02

Reference standards (3)

KMW-01
KMW-02
KMW-03

The same scope as data (JSON): https://labcoda.pl/api/accreditation-scopes/labs/PL/AP%20204