🇵🇱 Guenther Polska Sp. z o.o. PL
Metrology & calibration
Guenther Polska Sp. z o.o. is a calibration laboratory accredited by PCA under number AP 201 (Długołęka, Poland). Its accreditation scope covers 9 calibration items in the following areas: Metrology & calibration. Calibrated items include: Temperature simulators, Temperature indicators (meters) working with resistance sensors, Temperature indicators (meters) working with thermocouple sensors, Base metal thermocouples. Most frequently used calibration principles: Internal procedure; At permanent location (S), Internal procedure; Outside of permanent location (P).
At a glance
- Accreditation number: PCA AP 201
- Calibration items in scope: 9
- Types of calibrated items: 10
- Calibration principles used: 2
- City: Długołęka, Poland
- Valid until: 24-11-2029
- Accreditation number
- AP 201
- Accreditation body
- PCA
- Address
- ul. Wrocławska 27C, 55-095 Długołęka
- City
- Długołęka, Poland
- Division
- Laboratorium Pomiarowe
- Valid until
- 24-11-2029
What this laboratory calibrates (10)
- Temperature simulators — 4 calibration items
- Temperature indicators (meters) working with resistance sensors — 2 calibration items
- Temperature indicators (meters) working with thermocouple sensors — 2 calibration items
- Base metal thermocouples — 1 calibration item
- Electrical thermometers (including electronic) — 1 calibration item
- Furnaces — 1 calibration item
- Noble metal thermocouples — 1 calibration item
- Resistance thermometer sensors — 1 calibration item
- Temperature transmitters (including temperature sensors) — 1 calibration item
- Thermostatic chambers — 1 calibration item
Calibration principles (2)
- Internal procedure; At permanent location (S) — 6 calibration items
- Internal procedure; Outside of permanent location (P) — 3 calibration items
Certificate information
- Issue date
- 01.07.2026
- Issue no.
- 5
- Certificate date
- 25.11.2021
- Accreditation cycle
- 06.11.2025 — 24.11.2029
- Approved by
- Katarzyna Wiśniewska
Accreditation scope — calibration items (9)
| No. | Calibrated quantity / subject of calibration | Nominal range / parameters / CMC | Calibration principle | Calibration procedure | |
|---|---|---|---|---|---|
| Calibration items | |||||
| 1 | Temperature simulators Temperature indicators (meters) working with thermocouple sensors |
Calibration — Electrical simulation of temperature -100 °C to 1700 °C · CMC 0,7 °C Electrical simulation of temperature |
Internal procedure; Outside of permanent location (P) | QMV9.03.01, QMV9.03.02 w oparciu o EURAMET cg-11 v.2.0 | |
| 2 | Temperature simulators Temperature indicators (meters) working with thermocouple sensors |
Calibration — Electrical simulation of temperature -100 °C to 1700 °C · CMC 0,28 °C Electrical simulation of temperature |
Internal procedure; At permanent location (S) | QMV9.03.01, QMV9.03.02 w oparciu o EURAMET cg-11 v.2.0 | |
| 3 | Temperature simulators Temperature indicators (meters) working with resistance sensors |
Calibration — Electrical simulation of temperature -100 °C to 850 °C · CMC 0,3 °C Electrical simulation of temperature |
Internal procedure; Outside of permanent location (P) | QMV9.03.01, QMV9.03.02 w oparciu o EURAMET cg-11 v.2.0 | |
| 4 | Temperature simulators Temperature indicators (meters) working with resistance sensors |
Calibration — Electrical simulation of temperature -100 °C to 850 °C · CMC 0,12 °C Electrical simulation of temperature |
Internal procedure; At permanent location (S) | QMV9.03.01, QMV9.03.02 w oparciu o EURAMET cg-11 v.2.0 | |
| 5 | Noble metal thermocouples Base metal thermocouples |
Calibration — Temperature (electrical thermometry) -90 °C to 0 °C · CMC 0,5 °C 0 °C to 1085 °C · CMC 0,7 °C 1085 °C to 1200 °C · CMC 0,9 °C 1200 °C to 1300 °C · CMC 1,1 °C 1300 °C to 1400 °C · CMC 1,3 °C 1400 °C to 1550 °C · CMC 1,8 °C Temperature (electrical thermometry) |
Internal procedure; At permanent location (S) | QMV9.01.01 w oparciu o EURAMET cg-8 v.3.1 oraz ASTM E220-25 | |
| 6 | Resistance thermometer sensors | Calibration — Temperature (electrical thermometry) -90 °C to -20 °C · CMC 0,10 °C -20 °C to 100 °C · CMC 0,07 °C 100 °C to 200 °C · CMC 0,10 °C 200 °C to 600 °C · CMC 0,20 °C Temperature (electrical thermometry) |
Internal procedure; At permanent location (S) | QMV9.02.01 | |
| 7 | Temperature transmitters (including temperature sensors) | Calibration — Temperature (electrical thermometry) -90 °C to -20 °C · CMC 0,10 °C -20 °C to 100 °C · CMC 0,07 °C 100 °C to 200 °C · CMC 0,10 °C 200 °C to 600 °C · CMC 0,21 °C 600 °C to 1085 °C · CMC 1,3 °C 1085 °C to 1200 °C · CMC 1,4 °C 1200 °C to 1300 °C · CMC 1,6 °C 1300 °C to 1400 °C · CMC 1,7 °C 1400 °C to 1550 °C · CMC 2,0 °C Temperature (electrical thermometry) |
Internal procedure; At permanent location (S) | QMV9.08.01 | |
| 8 | Electrical thermometers (including electronic) | Calibration — Temperature (electrical thermometry) -90 °C to -20 °C · CMC 0,10 °C -20 °C to 100 °C · CMC 0,07 °C 100 °C to 200 °C · CMC 0,10 °C 200 °C to 600 °C · CMC 0,21 °C 600 °C to 1085 °C · CMC 1,3 °C 1085 °C to 1200 °C · CMC 1,4 °C 1200 °C to 1300 °C · CMC 1,6 °C 1300 °C to 1400 °C · CMC 1,7 °C 1400 °C to 1550 °C · CMC 2,0 °C Temperature (electrical thermometry) |
Internal procedure; At permanent location (S) | QMV9.04.01 | |
| 9 | Thermostatic chambers Furnaces |
Calibration — Temperature (electrical thermometry) -90 °C to 1085 °C · CMC 2,3 °C (applies to a single measuring point in the space of the calibrated object) 1085 °C to 1300 °C · CMC 4,4 °C (applies to a single measuring point in the space of the calibrated object) 1300 °C to 1550 °C · CMC 4,7 °C (applies to a single measuring point in the space of the calibrated object) Temperature (electrical thermometry) |
Internal procedure; Outside of permanent location (P) | QMV9.07.01 w oparciu o EURAMET cg-20 v.5.0 | |
Reference standards (11)
ASTM E220-25
EURAMET cg-11 v.2.0
EURAMET cg-20 v.5.0
EURAMET cg-8 v.3.1
QMV9.01.01
QMV9.02.01
QMV9.03.01
QMV9.03.02
QMV9.04.01
QMV9.07.01
QMV9.08.01