PCA AP 196 • Warszawa, Poland • 4 calibration items

Metrology & calibration

Sieć Badawcza Łukasiewicz-Przemysłowy Instytut Automatyki i Pomiarów PIAP is a calibration laboratory accredited by PCA under number AP 196 (Warszawa, Poland). Its accreditation scope covers 4 calibration items in the following areas: Metrology & calibration. Calibrated items include: Electrical thermometers (including electronic), Electrical thermometers (with temperature recording), Hygrometers, Radiation pyrometers. Most frequently used calibration principles: Internal procedure; At permanent location (S), Internal procedure; Direct method; At permanent location (S), Internal procedure; Direct method. Calibration in a climatic chambe….

At a glance

  • Accreditation number: PCA AP 196
  • Calibration items in scope: 4
  • Types of calibrated items: 5
  • Calibration principles used: 4
  • City: Warszawa, Poland
  • Valid until: 01-08-2029
Accreditation number
AP 196
Accreditation body
PCA
Address
ul. Aleje Jerozolimskie 202, 02-486 Warszawa
City
Warszawa, Poland
Division
Laboratorium Pomiaru Temperatury i Wilgotności LPTW
Valid until
01-08-2029

What this laboratory calibrates (5)

Calibration principles (4)

Certificate information

Issue date
03.07.2025
Issue no.
4
Certificate date
24.09.2021
Accreditation cycle
03.07.2025 — 01.08.2029
Approved by
Katarzyna Wiśniewska

Accreditation scope — calibration items (4)

The uncertainty covered by the CMC is the expanded uncertainty with a coverage probability of approximately 95 %. The value expressed as a percentage is a relative measurement uncertainty and refers to a percentage contribution in the value of the measurand. In other cases, the uncertainty covered by the CMC is expressed in measurand units.

No. Calibrated quantity / subject of calibration Nominal range / parameters / CMC Calibration principle Calibration procedure
Calibration items
1 Hygrometers
Thermohygrometers
Calibration — Relative humidity
10 °C to 20 °C — 30 %rh to 80 %rh · CMC 1,3 %rh 20 °C to 40 °C — 20 %rh to 90 %rh · CMC 1,3 %rh 22,1 °C to 23,4 °C — 20 %rh to 80 %rh · CMC 1,1 %rh
Relative humidity
Internal procedure; Direct method; At permanent location (S) IN-OUP 62
2 Electrical thermometers (including electronic)
Electrical thermometers (with temperature recording)
Calibration — Temperature (electrical thermometry)
-30 °C to 80 °C · CMC 0,16 °C
Temperature (electrical thermometry)
Internal procedure; Direct method. Calibration in a climatic chamber; At permanent location (S) IN-OUP 61
3 Electrical thermometers (including electronic)
Electrical thermometers (with temperature recording)
Calibration — Temperature (electrical thermometry)
-30 °C to 80 °C · CMC 0,07 °C 80 °C to 150 °C · CMC 0,11 °C
Temperature (electrical thermometry)
Internal procedure; Direct method. Calibration in a liquid bath; At permanent location (S) IN-OUP 61
4 Radiation pyrometers Calibration — Temperature (radiation thermometry)
0 °C to 120 °C · CMC 1,4 °C
Temperature (radiation thermometry)
Internal procedure; At permanent location (S) IN-OUP 70