PCA AP 182 • Jachranka, Poland • 4 calibration items

Metrology & calibration

VKRAFT Sp. z o.o. is a calibration laboratory accredited by PCA under number AP 182 (Jachranka, Poland). Its accreditation scope covers 4 calibration items in the following areas: Metrology & calibration. Calibrated items include: Current transformers, Voltage transformers. Most frequently used calibration principles: Internal procedure; Bridge method; At permanent location (S), Internal procedure; Bridge method; Outside of permanent location (P).

At a glance

  • Accreditation number: PCA AP 182
  • Calibration items in scope: 4
  • Types of calibrated items: 2
  • Calibration principles used: 2
  • City: Jachranka, Poland
  • Valid until: 28-06-2030
Accreditation number
AP 182
Accreditation body
PCA
Address
Jachranka 45, 05-140 Jachranka
City
Jachranka, Poland
Division
Laboratorium Wzorcujące
Valid until
28-06-2030

What this laboratory calibrates (2)

Calibration principles (2)

Certificate information

Issue date
29.05.2026
Issue no.
9
Certificate date
15.09.2025
Accreditation cycle
29.05.2026 — 28.06.2030
Approved by
Katarzyna Wiśniewska

Accreditation scope — calibration items (4)

The uncertainty covered by the CMC is the expanded uncertainty with a coverage probability of approximately 95 %. The value expressed as a percentage is a relative measurement uncertainty and refers to a percentage contribution in the value of the measurand. In other cases, CMC is expressed in measurand units.

No. Calibrated quantity / subject of calibration Nominal range / parameters / CMC Calibration principle Calibration procedure
Calibration items
1 Current transformers Calibration — High voltage and current
ratio of alternating electric currents (50 Hz) — 0,5 A to 7500 A / 1 A · CMC 0,025 %; 1,5 min ratio of alternating electric currents (50 Hz) — 0,5 A to 7500 A / 5 A · CMC 0,025 %; 1,5 min
High voltage and current
Internal procedure; Bridge method; At permanent location (S) PW1 w oparciu o PN-EN 61869-2:2013-06
2 Current transformers Calibration — High voltage and current
ratio of alternating electric currents (50 Hz) — 0,5 A to 7500 A / 1 A · CMC 0,04 %; 2 min ratio of alternating electric currents (50 Hz) — 0,5 A to 7500 A / 5 A · CMC 0,04 %; 2 min
High voltage and current
Internal procedure; Bridge method; Outside of permanent location (P) PW1 w oparciu o PN-EN 61869-2:2013-06
3 Voltage transformers Calibration — High voltage and current
ratio of alternating electric voltages (50 Hz) — 0,44 kV to 20 kV / 0,1 kV · CMC 0,025 %; 1,5 min ratio of alternating electric voltages (50 Hz) — 0,44/√3 kV to 20/√3 kV / 0,1/√3 kV · CMC 0,025 %; 1,5 min ratio of alternating electric voltages (50 Hz) — 0,44 kV to 20 kV / 0,2 kV · CMC 0,025 %; 1,5 min
High voltage and current
Internal procedure; Bridge method; At permanent location (S) PW2 w oparciu o PN-EN 61869-3:2011
4 Voltage transformers Calibration — High voltage and current
ratio of alternating electric voltages (50 Hz) — 0,44 kV to 20 kV / 0,1 kV · CMC 0,04 %; 2 min ratio of alternating electric voltages (50 Hz) — 0,44/√3 kV to 20/√3 kV / 0,1/√3 kV · CMC 0,04 %; 2 min ratio of alternating electric voltages (50 Hz) — 0,44 kV to 20 kV / 0,2 kV · CMC 0,04 %; 2 min
High voltage and current
Internal procedure; Bridge method; Outside of permanent location (P) PW2 w oparciu o PN-EN 61869-3:2011

Reference standards (4)

PN-EN 61869-2:2013-06
PN-EN 61869-3:2011