🇵🇱 SONEL S.A. PL

PCA AP 173 • Świdnica, Poland • 27 calibration items

Metrology & calibration

SONEL S.A. is a calibration laboratory accredited by PCA under number AP 173 (Świdnica, Poland). Its accreditation scope covers 27 calibration items in the following areas: Metrology & calibration. Calibrated items include: Multimeters, Power network parameter meters, Power quality meters, Calibrators. Most frequently used calibration principles: Internal procedure; Direct method; At permanent location (S), Internal procedure; Direct / indirect method; At permanent location…, Internal procedure; At permanent location (S).

At a glance

  • Accreditation number: PCA AP 173
  • Calibration items in scope: 27
  • Types of calibrated items: 26
  • Calibration principles used: 7
  • City: Świdnica, Poland
  • Valid until: 01-03-2029
Accreditation number
AP 173
Accreditation body
PCA
Address
ul. Wokulskiego 11, 58-100 Świdnica
City
Świdnica, Poland
Division
Testing and Calibration Laboratory
Valid until
01-03-2029

What this laboratory calibrates (26)

Calibration principles (7)

Certificate information

Issue date
10.12.2025
Issue no.
11
Certificate date
05.03.2020
Accreditation cycle
24.02.2025 — 01.03.2029
Approved by
Katarzyna Wiśniewska

Accreditation scope — calibration items (27)

The uncertainty covered by the CMC is the expanded uncertainty with a coverage probability of approximately 95 % and is expressed in measurand units. A CMC uncertainty value expressed as a percentage is the relative measurement uncertainty and refers to the percentage of the value of the measurand.

No. Calibrated quantity / subject of calibration Nominal range / parameters / CMC Calibration principle Calibration procedure
Calibration items
1 Digital voltmeters
Multimeters
Power quality meters
Clamp meters
Calibration — DC voltage
0,2 mV to 200 mV · CMC 1 · 10⁻⁵ · U + 0,6 µV 0,2 V to 2 V · CMC 1 · 10⁻⁵ · U + 0,3 µV 2 V to 20 V · CMC 1,5 · 10⁻⁵ · U + 0,6 µV 20 V to 200 V · CMC 1,5 · 10⁻⁵ · U + 0,03 mV 200 V to 1000 V · CMC 1,5 · 10⁻⁵ · U + 0,9 mV
DC voltage
Internal procedure; Direct method; At permanent location (S) Internal procedure IW01 based on EURAMET cg-15 v. 3.0
2 Calibrators
Reference sources
Calibration — DC voltage
10 mV to 200 mV · CMC 0,0005 % 0,2 V to 1000 V · CMC 0,0004 %
DC voltage
Internal procedure; Direct method; At permanent location (S) Internal procedure IW02
3 Digital ammeters
Multimeters
Power quality meters
Calibration — DC current
2 µA to 200 µA · CMC 5 · 10⁻⁵ · I + 0,2 nA 0,2 mA to 2 mA · CMC 4 · 10⁻⁵ · I + 6 nA 2 mA to 20 mA · CMC 4 · 10⁻⁵ · I + 60 nA 20 mA to 200 mA · CMC 8 · 10⁻⁵ · I + 1,3 µA 0,2 A to 2 A · CMC 0,02 % 2 A to 20 A · CMC 0,04 %
DC current
Internal procedure; Direct method; At permanent location (S) Internal procedure IW01 based on EURAMET cg-15 v. 3.0
4 Clamp meters Calibration — DC current
10 mA to 10 A · CMC 0,07 % 10 A to 1000 A · CMC 0,33 % 1000 A to 2000 A · CMC 0,8 %
DC current
Internal procedure; Direct method; At permanent location (S) Internal procedure IW01 based on EURAMET cg-15 v. 3.0
5 Calibrators Calibration — DC current
2 µA to 200 mA · CMC 0,004 % 0,2 A to 2 A · CMC 0,02 % 2 A to 20 A · CMC 0,05 %
DC current
Internal procedure; Direct / indirect method; At permanent location (S) Internal procedure IW02
6 Digital voltmeters
Multimeters
Power quality meters
Clamp meters
Calibration — AC voltage
10 Hz to 40 Hz — 10 mV to 200 mV · CMC 0,021 % 10 Hz to 40 Hz — 0,2 V to 2 V · CMC 0,015 % 10 Hz to 40 Hz — 2 V to 20 V · CMC 0,016 % 40 Hz to 10 kHz — 0,2 mV to 200 mV · CMC 4 · 10⁻⁴ · U + 12 µV 40 Hz to 10 kHz — 0,2 V to 2 V · CMC 2,5 · 10⁻⁴ · U + 40 µV 40 Hz to 10 kHz — 2 V to 20 V · CMC 2,5 · 10⁻⁴ · U + 0,4 mV 40 Hz to 10 kHz — 20 V to 200 V · CMC 2 · 10⁻⁴ · U + 0,3 mV 40 Hz to 10 kHz — 200 V to 1000 V · CMC 2,5 · 10⁻⁴ · U +4 mV 10 kHz to 100 kHz — 0,2 mV to 200 mV · CMC 6 · 10⁻⁴ · U + 15 µV 10 kHz to 100 kHz — 0,2 V to 2 V · CMC 4 · 10⁻⁴ · U + 70 µV 10 kHz to 100 kHz — 2 V to 20 V · CMC 4,5 · 10⁻⁴ · U + 0,8 mV 10 kHz to 100 kHz — 20 V to 300 V · CMC 4 · 10⁻⁴ · U + 7 mV
AC voltage
Internal procedure; Direct method; At permanent location (S) Internal procedure IW01 based on EURAMET cg-15 v. 3.0
7 Residual current device testers Calibration — AC voltage
0 V to 100 V · CMC 0,25 %
AC voltage
Internal procedure; Direct method; At permanent location (S) Internal procedure IW09
8 Calibrators Calibration — AC voltage
40 Hz to 100 Hz — 10 mV to 200 mV · CMC 0,05 % 40 Hz to 100 Hz — 0,2 V to 200 V · CMC 0,011 % 40 Hz to 100 Hz — 200 V to 1000 V · CMC 0,015 % 100 Hz to 2000 Hz — 10 mV to 200 mV · CMC 0,031 % 100 Hz to 2000 Hz — 0,2 V to 200 V · CMC 0,01 % 100 Hz to 2000 Hz — 200 V to 1000 V · CMC 0,015 % 2 kHz to 10 kHz — 10 mV to 200 mV · CMC 1,4 · 10⁻⁴ · U + 0,004 mV 2 kHz to 10 kHz — 0,2 V to 200 V · CMC 0,012 % 2 kHz to 10 kHz — 200 V to 1000 V · CMC 0,013 % 10 kHz to 30 kHz — 10 mV to 200 mV · CMC 3,4 · 10⁻⁴ · U + 0,008 mV 10 kHz to 30 kHz — 0,2 V to 200 V · CMC 0,024 % 10 kHz to 30 kHz — 200 V to 1000 V · CMC 0,026 % 30 kHz to 100 kHz — 10 mV to 200 mV · CMC 7,7 · 10⁻⁴ · U + 0,02 mV 30 kHz to 100 kHz — 0,2 V to 200 V · CMC 0,067 % 30 kHz to 100 kHz — 200 V to 1000 V · CMC 0,077 %
AC voltage
Internal procedure; Direct method; At permanent location (S) Internal procedure IW02
9 Digital ammeters
Multimeters
Power quality meters
Calibration — AC current
10 Hz to 1 kHz — 10 µA to 200 µA · CMC 0,068 % 10 Hz to 1 kHz — 0,2 mA to 200 mA · CMC 0,057 % 10 Hz to 1 kHz — 0,2 A to 2 A · CMC 0,042 % 10 Hz to 1 kHz — 2 A to 20 A · CMC 0,061 % 10 Hz to 1 kHz — 20 A to 150 A · CMC 0,2 %
AC current
Internal procedure; Direct method; At permanent location (S) Internal procedure IW01 based on EURAMET cg-15 v. 3.0
10 Digital ammeters
Multimeters
Power quality meters
Calibration — AC current
1 kHz to 5 kHz — 10 µA to 200 µA · CMC 0,045 % 1 kHz to 5 kHz — 0,2 mA to 200 mA · CMC 0,03 % 1 kHz to 5 kHz — 0,2 A to 2 A · CMC 0,062 % 1 kHz to 5 kHz — 2 A to 10 A · CMC 0,12 %
AC current
Internal procedure; Measurement of the RCD trip test current. Indirect method; At permanent location (S) Internal procedure IW09
11 Clamp meters Calibration — AC current
45 Hz to 65 Hz — 10 mA to 10 A · CMC 0,15 % 45 Hz to 65 Hz — 10 A to 1000 A · CMC 0,43 % 45 Hz to 65 Hz — 1000 A to 1900 A · CMC 0,8 % 400 Hz — 10 mA to 10 A · CMC 0,15 % 400 Hz — 10 A to 1000 A · CMC 0,43 %
AC current
Internal procedure; Direct method; At permanent location (S) Internal procedure IW01 based on EURAMET cg-15 v. 3.0
12 Calibrators Calibration — AC current
40 Hz to 1 kHz — 10 µA to 200 µA · CMC 0,061 % 40 Hz to 1 kHz — 0,2 mA to 200 mA · CMC 0,03 % 40 Hz to 1 kHz — 0,2 A to 2 A · CMC 0,04 % 40 Hz to 1 kHz — 2 A to 20 A · CMC 0,1 % 1 kHz to 10 kHz — 10 µA to 200 µA · CMC 0,25 % 1 kHz to 10 kHz — 0,2 mA to 200 mA · CMC 0,13 % 1 kHz to 10 kHz — 0,2 A to 2 A · CMC 0,16 % 1 kHz to 10 kHz — 2 A to 20 A · CMC 0,35 % 10 kHz to 20 kHz — 0,2 mA to 200 mA · CMC 0,17 % 50 Hz / 60 Hz — 2 A to 100 A · CMC 0,05 %
AC current
Internal procedure; Direct / indirect method; At permanent location (S) Internal procedure IW02
13 Electrical safety testers Calibration — AC current
0,04 mA to 20 mA · CMC 0,01 · I + 0,01 mA
AC current
Internal procedure; Measurement of the substitute leakage current. Direct method; At permanent location (S) Internal procedure IW01 based on EURAMET cg-15 v. 3.0
14 Digital ohmmeters
Multimeters
Calibration — DC resistance
20 µΩ · CMC 0,3 % 80 µΩ · CMC 0,1 % 150 µΩ · CMC 0,3 % 375 µΩ · CMC 0,3 % 750 µΩ · CMC 0,3 % 0,001 Ω to 1 Ω · CMC 0,02 % 0,1 Ω to 10,9999 Ω · CMC 0,03 % 11 Ω to 32,9999 Ω · CMC 0,008 % 33 Ω to 109,9999 Ω · CMC 0,008 % 110 Ω to 329,9999 Ω · CMC 0,005 % 330 Ω to 1,0999999 kΩ · CMC 0,005 % 1,1 kΩ to 3,299999 kΩ · CMC 0,005 % 3,3 kΩ to 32,99999 kΩ · CMC 0,005 % 33 kΩ to 109,9999 kΩ · CMC 0,005 % 110 kΩ to 329,9999 kΩ · CMC 0,005 % 330 kΩ to 1,0999999 MΩ · CMC 0,005 % 1,1 MΩ to 3,299999 MΩ · CMC 0,008 % 3,3 MΩ to 10,99999 MΩ · CMC 0,02 % 11 MΩ to 32,99999 MΩ · CMC 0,05 % 33 MΩ to 109,9999 MΩ · CMC 0,06 % 110 MΩ to 329,9999 MΩ · CMC 0,4 % 330 MΩ to 1100 MΩ · CMC 2%
DC resistance
Internal procedure; Direct method; At permanent location (S) Internal procedure IW01 based on EURAMET cg-15 v. 3.0
15 Insulation resistance meters Calibration — DC resistance
test voltage up to 15 kV — 50 kΩ to 10 TΩ · CMC 0,6 % test voltage up to 15 kV — 11 TΩ · CMC 0,5 % test voltage up to 15 kV — 20 TΩ · CMC 0,5 %
DC resistance
Internal procedure; Direct method; At permanent location (S) Internal procedure IW01 based on EURAMET cg-15 v. 3.0
16 Shunts
Resistance standards
Fixed resistors
Variable resistors
Resistance calibrators
Calibration — DC resistance
20 µΩ to 80 µΩ · CMC 0,1 % 80 µΩ to 0,01 Ω · CMC 0,06 % 0,01 Ω to 0,1 Ω · CMC 0,02 % 0,1 Ω to 2 Ω · CMC 0,002 % 2 Ω to 20 Ω · CMC 0,002 % 20 Ω to 200 kΩ · CMC 0,002 % 200 kΩ to 2 MΩ · CMC 0,003 % 2 MΩ to 20 MΩ · CMC 0,004 % 20 MΩ to 200 MΩ · CMC 0,006 % 200 MΩ to 2 GΩ · CMC 0,01 % 2 GΩ to 20 GΩ · CMC 0,11 %
DC resistance
Internal procedure; Direct / indirect method; At permanent location (S) Internal procedure IW02, IW04
17 Resistance standards
Fixed resistors
Variable resistors
Resistance calibrators
Calibration — DC resistance
test voltage up to 15 kV — 50 kΩ to 2,2 TΩ · CMC 0,6 % test voltage up to 15 kV — 2,2 TΩ to 10 TΩ · CMC 0,5 % test voltage up to 15 kV — 11 TΩ · CMC 0,5 % test voltage up to 15 kV — 20 TΩ · CMC 0,5 % test voltage up to 1 kV — 20 TΩ to 42 TΩ · CMC 2,6 %
DC resistance
Internal procedure; Indirect method; At permanent location (S) Internal procedure IW03
18 Digital ohmmeters
Power network parameter meters
Calibration — AC resistance
50 Hz to 200 Hz — 0,1 Ω to 0,4 Ω · CMC 0,7 % 50 Hz to 200 Hz — 0,4 Ω to 3 Ω · CMC 0,6 % 50 Hz to 200 Hz — 3 Ω to 19,9 kΩ · CMC 0,15 %
AC resistance
Internal procedure; Direct method; At permanent location (S) Internal procedure IW01 based on EURAMET cg-15 v. 3.0
19 Fault loop resistance meters
Residual current device testers
Calibration — AC resistance
50 Hz / 60 Hz — 100 mΩ to 250 mΩ · CMC 0,6 % 50 Hz / 60 Hz — 250 mΩ to 1000 mΩ · CMC 0,3 % 50 Hz / 60 Hz — 1000 mΩ to 2000 mΩ · CMC 0,12 % 50 Hz / 60 Hz — 2 Ω to 19 Ω · CMC 0,3 % 50 Hz / 60 Hz — 19 Ω to 2 kΩ · CMC 0,06 %
AC resistance
Internal procedure; Direct method; At permanent location (S) Internal procedure IW07, IW09
20 Digital ohmmeters
Electrical safety testers
Calibration — AC resistance
current up to 25 A; 50 Hz to 200 Hz — 20 mΩ to 50 mΩ · CMC 2% current up to 25 A; 50 Hz to 200 Hz — 50 mΩ to 30 Ω · CMC 1%
AC resistance
Internal procedure; Direct method; At permanent location (S) Internal procedure IW01 based on EURAMET cg-15 v. 3.0
21 Impedance meters
Power network parameter meters
Calibration — Impedance
100 mΩ to 250 mΩ · CMC 0,6 % 250 mΩ to 1000 mΩ · CMC 0,3 % 1000 mΩ to 2000 mΩ · CMC 0,12 % 2 Ω to 19 Ω · CMC 0,3 % 19 Ω to 2 kΩ · CMC 0,06 %
Impedance
Internal procedure; Direct method; At permanent location (S) Internal procedure IW07
22 Earth resistance meters
Power network parameter meters
Calibration — Impedance
0,2 Ω to 200 Ω · CMC 0,01 · R + 0,1 Ω
Impedance
Internal procedure; Measurement of earthing impedance by the impulse method. Direct method; At permanent location (S) Internal procedure IW07
23 Digital single-phase active power meters
Digital three-phase active power meters
Power network parameter meters
Power quality meters
Calibration — AC power
100 W to 150 kW; 40 Hz to 70 Hz; 1 A to 1000 A; 100 V to 500 V; cosφ = 1 · CMC 0,05 %
AC power
Internal procedure; Direct method; At permanent location (S) Internal procedure IW11
24 Digital single-phase apparent power meters
Digital three-phase apparent power meters
Power network parameter meters
Power quality meters
Calibration — AC power
100 VA to 150 kVA; 40 Hz to 70 Hz; 1 A to 1000 A; 100 V to 500 V · CMC 0,05 %
AC power
Internal procedure; Direct method; At permanent location (S) Internal procedure IW11
25 Power network parameter meters Calibration — Time (time interval)
5 ms to 190 ms · CMC 1,1 ms 190 ms to 390 ms · CMC 1,2 ms 390 ms to 1000 ms · CMC 8,2 ms
Time (time interval)
Internal procedure; Direct method; At permanent location (S) Internal procedure IW09
26 Power network parameter meters
Multimeters
Digital frequency meters
Calibration — Frequency
10 Hz to 100 Hz · CMC 3·10⁻⁶ · F 100 Hz to 1000 Hz · CMC 3·10⁻⁶ · F 1 kHz to 10 kHz · CMC 3·10⁻⁶ · F 10 kHz to 100 kHz · CMC 3·10⁻⁶ · F 100 kHz to 500 kHz · CMC 3·10⁻⁶ · F
Frequency
Internal procedure; Direct method; At permanent location (S) Internal procedure IW10
27 Pyrometers (including radiation, photoelectric and multiband pyrometers, thermal imaging cameras) Calibration — Temperature (radiation thermometry)
0 °C to 50 °C · CMC 1,1 °C 50 °C to 100 °C · CMC 1,4 °C 100 °C to 400 °C · CMC 1,6 °C 400 °C to 500 °C · CMC 3,5 °C
Temperature (radiation thermometry)
Internal procedure; At permanent location (S) Internal procedure IW06

Reference standards (10)

EURAMET cg-15 v. 3.0
IW01
IW02
IW03
IW04
IW06
IW07
IW09
IW10
IW11

The same scope as data (JSON): https://labcoda.pl/api/accreditation-scopes/labs/PL/AP%20173