🇵🇱 PROENERGA Sp z o.o. PL
Metrology & calibration
PROENERGA Sp z o.o. is a calibration laboratory accredited by PCA under number AP 166 (Płock, Poland). Its accreditation scope covers 3 calibration items in the following areas: Metrology & calibration. Calibrated items include: Combined instrument transformers, Current transformers, Voltage transformers. Most frequently used calibration principles: Internal procedure; Bridge method; Outside of permanent location (P).
At a glance
- Accreditation number: PCA AP 166
- Calibration items in scope: 3
- Types of calibrated items: 3
- Calibration principles used: 1
- City: Płock, Poland
- Valid until: 23-10-2028
- Accreditation number
- AP 166
- Accreditation body
- PCA
- Address
- Al. Armii Krajowej 17, 09-410 Płock
- City
- Płock, Poland
- Division
- Laboratorium Wzorcujące PROENERGA
- Valid until
- 23-10-2028
What this laboratory calibrates (3)
- Combined instrument transformers — 1 calibration item
- Current transformers — 1 calibration item
- Voltage transformers — 1 calibration item
Calibration principles (1)
- Internal procedure; Bridge method; Outside of permanent location (P) — 3 calibration items
Certificate information
- Issue date
- 30.07.2026
- Issue no.
- 9
- Certificate date
- 26.01.2023
- Accreditation cycle
- 08.10.2024 — 23.10.2028
- Approved by
- Katarzyna Wiśniewska
Accreditation scope — calibration items (3)
| No. | Calibrated quantity / subject of calibration | Nominal range / parameters / CMC | Calibration principle | Calibration procedure | |
|---|---|---|---|---|---|
| Calibration items | |||||
| 1 | Current transformers | Calibration — High voltage and current ratio of alternating electric currents (50 Hz) — 0,5 A to 5000 A / 5 A · CMC 0,03 %; 1,6 min ratio of alternating electric currents (50 Hz) — 0,5 A to 5000 A / 1 A · CMC 0,03 %; 1,6 min High voltage and current |
Internal procedure; Bridge method; Outside of permanent location (P) | PP1 w oparciu o PN-EN 61869-2:2013-06 | |
| 2 | Voltage transformers | Calibration — High voltage and current ratio of alternating electric voltages (50 Hz) — 0,44 kV to 110 kV / 0,10 kV · CMC 0,03 %; 1,6 min ratio of alternating electric voltages (50 Hz) — 0,44/√3 kV to 110/√3 kV / 0,10/√3 kV · CMC 0,03 %; 1,6 min ratio of alternating electric voltages (50 Hz) — 0,44 kV to 110 kV / 0,11 kV · CMC 0,03 %; 1,6 min ratio of alternating electric voltages (50 Hz) — 0,44/√3 kV to 110/√3 kV / 0,11/√3 kV · CMC 0,03 %; 1,6 min High voltage and current |
Internal procedure; Bridge method; Outside of permanent location (P) | PP2 w oparciu o PN-EN 61869-3:2011 | |
| 3 | Combined instrument transformers | Calibration — High voltage and current ratio of alternating electric currents (50 Hz) — 0,5 A to 5000 A / 5 A · CMC 0,03 %; 1,6 min ratio of alternating electric currents (50 Hz) — 0,5 A to 5000 A / 1 A · CMC 0,03 %; 1,6 min ratio of alternating electric voltages (50 Hz) — 0,44 kV to 110 kV / 0,10 kV · CMC 0,03 %; 1,6 min ratio of alternating electric voltages (50 Hz) — 0,44/√3 kV to 110/√3 kV / 0,10/√3 kV · CMC 0,03 %; 1,6 min ratio of alternating electric voltages (50 Hz) — 0,44 kV to 110 kV / 0,11 kV · CMC 0,03 %; 1,6 min ratio of alternating electric voltages (50 Hz) — 0,44/√3 kV to 110/√3 kV / 0,10/√3 kV · CMC 0,03 %; 1,6 min High voltage and current |
Internal procedure; Bridge method; Outside of permanent location (P) | PP3 w oparciu o PN-EN 61869-2:2013-06 PN-EN 61869-3:2011 | |
Reference standards (5)
PN-EN 61869-2:2013-06
PN-EN 61869-3:2011
PP1
PP2
PP3