PCA AP 157 • Skarbimierz-Osiedle, Poland • 6 calibration items

Metrology & calibration

MIW GROUP Sp. z o.o. is a calibration laboratory accredited by PCA under number AP 157 (Skarbimierz-Osiedle, Poland). Its accreditation scope covers 6 calibration items in the following areas: Metrology & calibration. Calibrated items include: Non-automatic electronic weighing instruments, 25 kg mass standards, Automatic belt weighers, Mass standards of accuracy classes M1, M2, M3. Most frequently used calibration principles: At permanent location (S) and outside of it (P), Method using substitution material; Outside of permanent location (P), The measuring range refers to the largest mass of a portion of mate….

At a glance

  • Accreditation number: PCA AP 157
  • Calibration items in scope: 6
  • Types of calibrated items: 4
  • Calibration principles used: 3
  • City: Skarbimierz-Osiedle, Poland
  • Valid until: 22-02-2027
Accreditation number
AP 157
Accreditation body
PCA
Address
ul. Wierzbowa 23, 49-318 Skarbimierz-Osiedle
City
Skarbimierz-Osiedle, Poland
Division
Laboratorium Wzorcujące LAB-SCALE
Valid until
22-02-2027

What this laboratory calibrates (4)

Calibration principles (3)

Certificate information

Issue date
15.12.2025
Issue no.
13
Certificate date
06.02.2020
Accreditation cycle
20.02.2023 — 22.02.2027
Approved by
Katarzyna Wiśniewska

Accreditation scope — calibration items (6)

The uncertainty covered by the CMC is the expanded uncertainty with a coverage probability of approximately 95 % and is expressed in measurand units. The measurement uncertainty value for CMC expressed as a percentage is a relative measurement uncertainty and refers to a percentage contribution in the value of the measurand.

No. Calibrated quantity / subject of calibration Nominal range / parameters / CMC Calibration principle Calibration procedure
Calibration items
1 Non-automatic electronic weighing instruments Calibration — Mass (weighing instruments)
up to 600 g · CMC 1,4 · 10⁻³ % 0,6 kg to 6 kg · CMC 2,0 · 10⁻³ %
Mass (weighing instruments)
At permanent location (S) and outside of it (P) EURAMET cg-18 v.4.0
2 Non-automatic electronic weighing instruments Calibration — Mass (weighing instruments)
6 kg to 140 000 kg · CMC 2,2 · 10⁻² %
Mass (weighing instruments)
At permanent location (S) and outside of it (P) EURAMET cg-18 v.4.0
3 Non-automatic electronic weighing instruments Calibration — Mass (weighing instruments)
up to 5 000 kg · CMC 1,3 · 10⁻¹ % 5 000 kg to 140 000 kg · CMC 5,8 · 10⁻² %
Mass (weighing instruments)
Method using substitution material; Outside of permanent location (P) EURAMET cg-18 v.4.0
4 Automatic belt weighers Calibration — Mass (weighing instruments)
up to 140 000 kg · CMC 0,2 %
Mass (weighing instruments)
The measuring range refers to the largest mass of a portion of material weighed at one time on the non-automatic control instrument; Outside of permanent location (P) OIML R 50-1:2014 (p. 7) OIML R 50-2:2014 (p. 10)
5 Mass standards of accuracy classes M1, M2, M3 Calibration — Mass (weights and mass standards)
20 kg · CMC 300 mg 500 kg · CMC 8 g 1000 kg · CMC 16 g 2000 kg · CMC 32 g
Mass (weights and mass standards)
At permanent location (S) and outside of it (P) OIML R 111-1:2004 Załącznik C
6 25 kg mass standards Calibration — Mass (weights and mass standards)
25 kg · CMC 400 mg
Mass (weights and mass standards)
At permanent location (S) and outside of it (P) OIML R 111-1:2004 Załącznik C

Reference standards (4)

EURAMET cg-18 v.4.0
OIML R 111-1:2004
OIML R 50-1:2014
OIML R 50-2:2014

The same scope as data (JSON): https://labcoda.pl/api/accreditation-scopes/labs/PL/AP%20157