🇵🇱 ZOK Sp. z o.o. PL

PCA AP 143 • Jastrzębie Zdrój, Poland • 3 calibration items

Metrology & calibration

ZOK Sp. z o.o. is a calibration laboratory accredited by PCA under number AP 143 (Jastrzębie Zdrój, Poland). Its accreditation scope covers 3 calibration items in the following areas: Metrology & calibration. Calibrated items include: Carbon dioxide in a gas mixture, Carbon monoxide in a gas mixture, Methane in a gas mixture. Most frequently used calibration principles: Internal procedure; Gas chromatography method; At permanent locatio…, Internal procedure; Measurement method using non-dispersive infrare….

At a glance

  • Accreditation number: PCA AP 143
  • Calibration items in scope: 3
  • Types of calibrated items: 3
  • Calibration principles used: 2
  • City: Jastrzębie Zdrój, Poland
  • Valid until: 01-12-2027
Accreditation number
AP 143
Accreditation body
PCA
Address
ul. Boczna 24, 44-335 Jastrzębie Zdrój
City
Jastrzębie Zdrój, Poland
Division
Laboratorium Badawcze i Wzorcujące
Valid until
01-12-2027

What this laboratory calibrates (3)

Calibration principles (2)

Certificate information

Issue date
11.07.2025
Issue no.
15
Certificate date
05.11.2019
Accreditation cycle
06.11.2023 — 01.12.2027
Approved by
Katarzyna Wiśniewska

Accreditation scope — calibration items (3)

The uncertainty covered by the CMC does not include the uncertainty components related to the stability and homogeneity of the reference material. The measurement uncertainty value for CMC expressed as a percentage is a relative measurement uncertainty and refers to a percentage contribution in the value of the measurand.

No. Calibrated quantity / subject of calibration Nominal range / parameters / CMC Calibration principle Calibration procedure
Calibration items
1 Carbon monoxide in a gas mixture Measurement — Reference materials
7 · 10⁻⁶ mol/mol to 30 · 10⁻⁶ mol/mol · CMC 4,0 % 30 · 10⁻⁶ mol/mol to 320 · 10⁻⁶ mol/mol · CMC 2,0 %
Reference materials
Internal procedure; Measurement method using non-dispersive infrared spectroscopy (NDIR); At permanent location (S) PW-01
2 Methane in a gas mixture Measurement — Reference materials
0,2 · 10⁻² mol/mol to 80,0 · 10⁻² mol/mol · CMC 1,5 %
Reference materials
Internal procedure; Gas chromatography method; At permanent location (S) IW-01 w oparciu o PN-EN ISO 6143:2010
3 Carbon dioxide in a gas mixture Measurement — Reference materials
0,2 · 10⁻² mol/mol to 40,0 · 10⁻² mol/mol · CMC 1,5 %
Reference materials
Internal procedure; Gas chromatography method; At permanent location (S) IW-01 w oparciu o PN-EN ISO 6143:2010

Reference standards (3)

IW-01
PN-EN ISO 6143:2010
PW-01

The same scope as data (JSON): https://labcoda.pl/api/accreditation-scopes/labs/PL/AP%20143