🇵🇱 Astem Sp. z o.o. PL
Metrology & calibration
Astem Sp. z o.o. is a calibration laboratory accredited by PCA under number AP 127 (Dębica, Poland). Its accreditation scope covers 14 calibration items in the following areas: Metrology & calibration. Calibrated items include: Electronic pressure gauges, Pressure transducers, Spring pressure gauges, Analog dial indicators with scale interval of 0,01 mm. Most frequently used calibration principles: Internal procedure; At permanent location (S), At permanent location (S).
At a glance
- Accreditation number: PCA AP 127
- Calibration items in scope: 14
- Types of calibrated items: 17
- Calibration principles used: 2
- City: Dębica, Poland
- Valid until: 01-10-2029
- Accreditation number
- AP 127
- Accreditation body
- PCA
- Address
- ul. 1 Maja 1, 39-200 Dębica
- City
- Dębica, Poland
- Division
- Zespół Laboratoriów Pomiarowych
- Valid until
- 01-10-2029
What this laboratory calibrates (17)
- Electronic pressure gauges — 2 calibration items
- Pressure transducers — 2 calibration items
- Spring pressure gauges — 2 calibration items
- Analog dial indicators with scale interval of 0,01 mm — 1 calibration item
- Base metal thermocouples — 1 calibration item
- Calipers — 1 calibration item
- Digital indicators with resolution of 0,01 mm — 1 calibration item
- Electrical thermometers (including electronic) — 1 calibration item
- External micrometers — 1 calibration item
- Pyrometers — 1 calibration item
- Resistance thermometer sensors — 1 calibration item
- Rigid rules — 1 calibration item
- Semi-rigid rules — 1 calibration item
- Tape measures — 1 calibration item
- Temperature indicators (meters), including temperature controllers — 1 calibration item
- and 2 more
Calibration principles (2)
- Internal procedure; At permanent location (S) — 12 calibration items
- At permanent location (S) — 2 calibration items
Certificate information
- Issue date
- 30.06.2026
- Issue no.
- 22
- Certificate date
- 30.08.2022
- Accreditation cycle
- 11.09.2025 — 01.10.2029
- Approved by
- Katarzyna Wiśniewska
Accreditation scope — calibration items (14)
| No. | Calibrated quantity / subject of calibration | Nominal range / parameters / CMC | Calibration principle | Calibration procedure | |
|---|---|---|---|---|---|
| Calibration items | |||||
| 1 | Calipers | Calibration — Length 0 mm to 600 mm · CMC 18 μm Length |
At permanent location (S) | PN-EN ISO 13385-1:2019 | |
| 2 | Analog dial indicators with scale interval of 0,01 mm | Calibration — Length 0 mm to 50 mm · CMC 5 μm Length |
Internal procedure; At permanent location (S) | PP/LD-42/52 | |
| 3 | Digital indicators with resolution of 0,01 mm | Calibration — Length 0 mm to 50,8 mm · CMC 5 μm Length |
At permanent location (S) | PN-EN ISO 13102:2013 | |
| 4 | Tape measures Rigid rules Semi-rigid rules |
Calibration — Length 0 m to 5 m · CMC Q[0,12; 0,022 · L] mm; L – measured length (m) Length |
Internal procedure; At permanent location (S) | PP/LD-44/54 | |
| 5 | External micrometers | Calibration — Length 0 mm to 25 mm · CMC 0,9 μm 25 mm to 50 mm · CMC 1,1 μm 50 mm to 75 mm · CMC 1,3 μm 75 mm to 100 mm · CMC 1,7 μm 100 mm to 125 mm · CMC 2,0 μm 125 mm to 150 mm · CMC 2,4 μm 150 mm to 175 mm · CMC 2,7 μm 175 mm to 200 mm · CMC 3,1 μm Length |
Internal procedure; At permanent location (S) | PP/LD-46/56 | |
| 6 | Temperature indicators (meters), including temperature controllers Temperature simulators Temperature transducers |
Calibration — Electrical simulation of quantities for RTD sensors — -200 °C to 850 °C · CMC 0.08 °C for PT sensors — -200 °C to 1370 °C · CMC 0,4 °C Electrical simulation of quantities |
Internal procedure; At permanent location (S) | PP/LT-30 | |
| 7 | Electronic pressure gauges Spring pressure gauges |
Calibration — Pressure gauge pressure — -0,09 MPa to 0 MPa · CMC 0,0004 MPa gauge pressure — 0 MPa to 0,07 MPa · CMC 0,00012 MPa gauge pressure — 0,07 MPa to 0,7 MPa · CMC 0,00036 MPa gauge pressure — 0,7 MPa to 7,0 MPa · CMC 0,0036 MPa gauge pressure — 7,0 MPa to 70,0 MPa · CMC 0,036 MPa Pressure |
Internal procedure; At permanent location (S) | PP/LC-17 | |
| 8 | Electronic pressure gauges Spring pressure gauges |
Calibration — Pressure absolute pressure — 0 MPa to 0,7 MPa · CMC 0,0007 MPa absolute pressure — 0 MPa to 0,7 MPa · CMC 0,0007 MPa Pressure |
Internal procedure; At permanent location (S) | PP/LC-17 | |
| 9 | Pressure transducers | Calibration — Pressure gauge pressure — 0,0 MPa to 0,4 MPa · CMC 0,001 MPa gauge pressure — 0,4 MPa to 6,0 MPa · CMC 0,007 MPa gauge pressure — 6,0 MPa to 70,0 MPa · CMC 0,07 MPa Pressure |
Internal procedure; At permanent location (S) | PP/LC-19 | |
| 10 | Pressure transducers | Calibration — Pressure absolute pressure — 0 MPa to 0,7 MPa · CMC 0,0007 MPa Pressure |
Internal procedure; At permanent location (S) | PP/LC-19 | |
| 11 | Resistance thermometer sensors | Calibration — Temperature (electrical thermometry) -20 °C to 425 °C · CMC 5 · 10⁻⁴ · |t| + 0,02 °C; t – measured value (°C) Temperature (electrical thermometry) |
Internal procedure; At permanent location (S) | PP/LT-31 | |
| 12 | Base metal thermocouples | Calibration — Temperature (electrical thermometry) -20 °C to 425 °C · CMC 2 · 10⁻³ · |t| + 0,4 °C; t – measured value (°C) Temperature (electrical thermometry) |
Internal procedure; At permanent location (S) | PP/LT-32 | |
| 13 | Electrical thermometers (including electronic) | Calibration — Temperature (electrical thermometry) -20 °C to 425 °C · CMC 0,2 °C Temperature (electrical thermometry) |
Internal procedure; At permanent location (S) | PP/LT-35 | |
| 14 | Pyrometers | Calibration — Temperature (radiation thermometry) -20 °C to 350 °C · CMC 5 · 10⁻³ · |t| + 0,8 °C; t – measured value (°C) Temperature (radiation thermometry) |
Internal procedure; At permanent location (S) | PP/LT-34 w oparciu o MSL Guide No. 22 v.3 | |
Reference standards (13)
MSL Guide No. 22 v.3
PN-EN ISO 13102:2013
PN-EN ISO 13385-1:2019
PP/LC-17
PP/LC-19
PP/LD-42/52
PP/LD-44/54
PP/LD-46/56
PP/LT-30
PP/LT-31
PP/LT-32
PP/LT-34
PP/LT-35