PGE Dystrybucja S.A. Oddział Lublin is a calibration laboratory accredited by PCA under number AP 124 (Lublin, Poland). Its accreditation scope covers 2 calibration items in the following areas: Metrology & calibration. Calibrated items include: AC active electrical energy meters, AC reactive electrical energy meters. Most frequently used calibration principles: Internal procedure; Direct method; At permanent location (S).

At a glance

  • Accreditation number: PCA AP 124
  • Calibration items in scope: 2
  • Types of calibrated items: 2
  • Calibration principles used: 1
  • City: Lublin, Poland
  • Valid until: 18-05-2029
Accreditation number
AP 124
Accreditation body
PCA
Address
ul. Pancerniaków 8, 20-331 Lublin
City
Lublin, Poland
Division
Laboratorium Wzorcujące
Valid until
18-05-2029

What this laboratory calibrates (2)

Calibration principles (1)

Certificate information

Issue date
27.01.2026
Issue no.
14
Certificate date
27.01.2026
Accreditation cycle
23.04.2025 — 18.05.2029
Approved by
Katarzyna Wiśniewska

Accreditation scope — calibration items (2)

The uncertainty covered by the CMC is the expanded uncertainty with a coverage probability of approximately 95 %. The value expressed as a percentage is a relative measurement uncertainty and refers to a percentage contribution in the value of the measurand.

No. Calibrated quantity / subject of calibration Nominal range / parameters / CMC Calibration principle Calibration procedure
Calibration items
1 AC active electrical energy meters Calibration — Energy
cos φ = 1 or cos φ = -1 — 50 Hz; 30 V to 300 V; 0,02 A to 100 A; cos φ inductive or capacitive · CMC 0,046 % cos φ = 0,8 or cos φ = -0,8 — 50 Hz; 30 V to 300 V; 0,02 A to 100 A; cos φ inductive or capacitive · CMC 0,046 % cos φ = 0,5 or cos φ = -0,5 — 50 Hz; 30 V to 300 V; 0,02 A to 100 A; cos φ inductive or capacitive · CMC 0,046 %
Energy
Internal procedure; Direct method; At permanent location (S) I-01, I-03
2 AC reactive electrical energy meters Calibration — Energy
sin φ = 1 or sin φ = -1 — 50 Hz; 30 V to 300 V; 0,02 A to 100 A; sin φ inductive or capacitive · CMC 0,046 % sin φ = 0,8 or sin φ = -0,8 — 50 Hz; 30 V to 300 V; 0,02 A to 100 A; sin φ inductive or capacitive · CMC 0,046 % sin φ = 0,5 or sin φ = -0,5 — 50 Hz; 30 V to 300 V; 0,02 A to 100 A; sin φ inductive or capacitive · CMC 0,046 %
Energy
Internal procedure; Direct method; At permanent location (S) I-01, I-03

Reference standards (2)

I-01
I-03

The same scope as data (JSON): https://labcoda.pl/api/accreditation-scopes/labs/PL/AP%20124