🇵🇱 Instytut Mechaniki Górotworu Polskiej Akademii Nauk PL
Metrology & calibration
Instytut Mechaniki Górotworu Polskiej Akademii Nauk is a calibration laboratory accredited by PCA under number AP 118 (Kraków, Poland). Its accreditation scope covers 7 calibration items in the following areas: Metrology & calibration. Calibrated items include: Anemometers, Electronic pressure gauges, Pitot tubes – determination of constant K1, Pitot tubes – determination of constant K2. Most frequently used calibration principles: Internal procedure; The CMC uncertainties refer to the dimensionles…, Internal procedure; At permanent location (S), Internal procedure; Measurement with a static Pitot tube; At perman….
At a glance
- Accreditation number: PCA AP 118
- Calibration items in scope: 7
- Types of calibrated items: 8
- Calibration principles used: 4
- City: Kraków, Poland
- Valid until: 01-09-2028
- Accreditation number
- AP 118
- Accreditation body
- PCA
- Address
- ul. Reymonta 27, 30-059 Kraków
- City
- Kraków, Poland
- Division
- Laboratorium Wzorcujące Wentylacyjne Przyrządy Pomiarowe
- Valid until
- 01-09-2028
What this laboratory calibrates (8)
- Anemometers — 2 calibration items
- Electronic pressure gauges — 1 calibration item
- Pitot tubes – determination of constant K1 — 1 calibration item
- Pitot tubes – determination of constant K2 — 1 calibration item
- Pitot tubes – determination of shape number B — 1 calibration item
- Pressure transducers — 1 calibration item
- Pressure transducers – barometers — 1 calibration item
- Spring pressure gauges – barometers — 1 calibration item
Calibration principles (4)
- Internal procedure; The CMC uncertainties refer to the dimensionless values of constants K1, K2 or of shape number B; At permanent location (S) — 3 calibration items
- Internal procedure; At permanent location (S) — 2 calibration items
- Internal procedure; Measurement with a static Pitot tube; At permanent location (S) — 1 calibration item
- Internal procedure; Orifice measurement; At permanent location (S) — 1 calibration item
Certificate information
- Issue date
- 13.07.2026
- Issue no.
- 15
- Certificate date
- 13.08.2020
- Accreditation cycle
- 05.08.2024 — 01.09.2028
- Approved by
- Katarzyna Wiśniewska
Accreditation scope — calibration items (7)
| No. | Calibrated quantity / subject of calibration | Nominal range / parameters / CMC | Calibration principle | Calibration procedure | |
|---|---|---|---|---|---|
| Calibration items | |||||
| 1 | Anemometers | Calibration — Air velocity (flow – gases) 0,15 m/s to 1,5 m/s · CMC 0,05 m/s Air velocity (flow – gases) |
Internal procedure; Orifice measurement; At permanent location (S) | P/01 | |
| 2 | Anemometers | Calibration — Air velocity (flow – gases) 1,5 m/s to 7 m/s · CMC -0,012 · V + 0,173 m/s; V – measured value (m/s) 7 m/s to 40 m/s · CMC 0,0083 · V + 0,0313 m/s; V – measured value (m/s) Air velocity (flow – gases) |
Internal procedure; Measurement with a static Pitot tube; At permanent location (S) | P/01 | |
| 3 | Pitot tubes – determination of constant K1 | Calibration — Air velocity (flow – gases) 1,5 m/s to 3 m/s · CMC -0,161 · V + 0,594; V – numerical value of velocity expressed in m/s 3 m/s to 6 m/s · CMC -0,027 · V + 0,193; V – numerical value of velocity expressed in m/s 6 m/s to 40 m/s · CMC 0,03 Air velocity (flow – gases) |
Internal procedure; The CMC uncertainties refer to the dimensionless values of constants K1, K2 or of shape number B; At permanent location (S) | P/03 | |
| 4 | Pitot tubes – determination of constant K2 | Calibration — Air velocity (flow – gases) 1,5 m/s to 3 m/s · CMC -0,113 · V + 0,420; V – numerical value of velocity expressed in m/s 3 m/s to 6 m/s · CMC -0,020 · V + 0,141; V – numerical value of velocity expressed in m/s 6 m/s to 40 m/s · CMC 0,02 Air velocity (flow – gases) |
Internal procedure; The CMC uncertainties refer to the dimensionless values of constants K1, K2 or of shape number B; At permanent location (S) | P/03 | |
| 5 | Pitot tubes – determination of shape number B | Calibration — Air velocity (flow – gases) 1,5 m/s to 3 m/s · CMC -0,230 · V + 0,854; V – numerical value of velocity expressed in m/s 3 m/s to 6 m/s · CMC -0,041 · V + 0,287; V – numerical value of velocity expressed in m/s 6 m/s to 40 m/s · CMC 0,04 Air velocity (flow – gases) |
Internal procedure; The CMC uncertainties refer to the dimensionless values of constants K1, K2 or of shape number B; At permanent location (S) | P/03 | |
| 6 | Spring pressure gauges – barometers Pressure transducers – barometers |
Calibration — Pressure absolute pressure — 200 hPa to 1300 hPa · CMC 0,11 hPa Pressure |
Internal procedure; At permanent location (S) | P/07 w oparciu o EURAMET cg-17 v. 4.1 | |
| 7 | Electronic pressure gauges Pressure transducers |
Calibration — Pressure gauge and differential pressure — 0 kPa to 7,5 kPa · CMC 0,001 kPa gauge and differential pressure — 7,5 kPa to 70 kPa · CMC 3,0·10⁻⁴ · p + 0,002 kPa; p – measured value (kPa) gauge and differential pressure — 70 kPa to 200 kPa · CMC 2,2·10⁻⁴ · p + 0,006 kPa; p – measured value (kPa) Pressure |
Internal procedure; At permanent location (S) | P/02 w oparciu o EURAMET cg-17 v. 4.1 | |
Reference standards (5)
EURAMET cg-17 v. 4.1
P/01
P/02
P/03
P/07