🇵🇱 TAURON Dystrybucja Pomiary sp. z o.o. PL

PCA AP 111 • Tarnów, Poland • 2 calibration items

Metrology & calibration

TAURON Dystrybucja Pomiary sp. z o.o. is a calibration laboratory accredited by PCA under number AP 111 (Tarnów, Poland). Its accreditation scope covers 2 calibration items in the following areas: Metrology & calibration. Calibrated items include: AC active electrical energy meters, AC reactive electrical energy meters. Most frequently used calibration principles: Internal procedure; Direct comparison method; At permanent location….

At a glance

  • Accreditation number: PCA AP 111
  • Calibration items in scope: 2
  • Types of calibrated items: 2
  • Calibration principles used: 1
  • City: Tarnów, Poland
  • Valid until: 18-12-2027
Accreditation number
AP 111
Accreditation body
PCA
Address
ul. Kryształowa 1/3, 33-100 Tarnów
City
Tarnów, Poland
Division
Laboratorium Akredytowane, AMI i OT
Valid until
18-12-2027

What this laboratory calibrates (2)

Calibration principles (1)

Certificate information

Issue date
05.01.2026
Issue no.
11
Certificate date
05.01.2026
Accreditation cycle
21.11.2023 — 18.12.2027
Approved by
Katarzyna Wiśniewska

Accreditation scope — calibration items (2)

The uncertainty covered by the CMC is the expanded uncertainty with a coverage probability of approximately 95 %. The value expressed as a percentage is a relative measurement uncertainty and refers to a percentage contribution in the value of the measurand.

No. Calibrated quantity / subject of calibration Nominal range / parameters / CMC Calibration principle Calibration procedure
Calibration items
1 AC active electrical energy meters Calibration — Energy
cos φ = 1 or cos φ = -1 — 50 Hz; 30 V to 350 V; 0,020 A to 120 A; cos φ inductive or capacitive · CMC 0,058 % cos φ = 0,8 or cos φ = -0,8 — 50 Hz; 30 V to 350 V; 0,020 A to 120 A; cos φ inductive or capacitive · CMC 0,058 % cos φ = 0,5 or cos φ = -0,5 — 50 Hz; 30 V to 350 V; 0,020 A to 120 A; cos φ inductive or capacitive · CMC 0,058 % cos φ = 0,25 or cos φ = -0,25 — 50 Hz; 30 V to 350 V; 0,020 A to 120 A; cos φ inductive or capacitive · CMC 0,093 %
Energy
Internal procedure; Direct comparison method; At permanent location (S) IL01
2 AC reactive electrical energy meters Calibration — Energy
sin φ = 1 or sin φ = -1 — 50 Hz; 30 V to 350 V; 0,020 A to 120 A; sin φ inductive or capacitive · CMC 0,058 % sin φ = 0,8 or sin φ = -0,8 — 50 Hz; 30 V to 350 V; 0,020 A to 120 A; sin φ inductive or capacitive · CMC 0,058 % sin φ = 0,5 or sin φ = -0,5 — 50 Hz; 30 V to 350 V; 0,020 A to 120 A; sin φ inductive or capacitive · CMC 0,058 % sin φ = 0,25 or sin φ = -0,25 — 50 Hz; 30 V to 350 V; 0,020 A to 120 A; sin φ inductive or capacitive · CMC 0,093 %
Energy
Internal procedure; Direct comparison method; At permanent location (S) IL01

Reference standards (1)

IL01

The same scope as data (JSON): https://labcoda.pl/api/accreditation-scopes/labs/PL/AP%20111