PCA AP 109 • Bydgoszcz, Poland • 2 calibration items

Metrology & calibration

POLON-ALFA sp. z o.o. is a calibration laboratory accredited by PCA under number AP 109 (Bydgoszcz, Poland). Its accreditation scope covers 2 calibration items in the following areas: Metrology & calibration. Calibrated items include: Calibration benches, Dosimetric instruments for X and gamma radiation measurement, Ionising radiation dosimeters, Ionising radiation rate meters. Most frequently used calibration principles: Internal procedure; At permanent location (S).

At a glance

  • Accreditation number: PCA AP 109
  • Calibration items in scope: 2
  • Types of calibrated items: 5
  • Calibration principles used: 1
  • City: Bydgoszcz, Poland
  • Valid until: 25-11-2027
Accreditation number
AP 109
Accreditation body
PCA
Address
ul. Glinki 155, 85-861 Bydgoszcz
City
Bydgoszcz, Poland
Division
Laboratorium Wzorcujące Urządzeń Dozymetrycznych
Valid until
25-11-2027

What this laboratory calibrates (5)

Calibration principles (1)

Certificate information

Issue date
07.07.2026
Issue no.
16
Certificate date
05.11.2019
Accreditation cycle
31.10.2023 — 25.11.2027
Approved by
Tadeusz Matras

Accreditation scope — calibration items (2)

The uncertainty covered by the CMC is the expanded uncertainty with a coverage probability of approximately 95 %. The value expressed as a percentage is a relative measurement uncertainty and refers to a percentage contribution in the value of the measurand. The current limits of the measurement ranges and the corresponding CMC uncertainty values, which change with the activity of the radioactive sources used, are available on request from the accredited body.

No. Calibrated quantity / subject of calibration Nominal range / parameters / CMC Calibration principle Calibration procedure
Calibration items
1 Personal dosimeters
Ionising radiation dosimeters
Dosimetric instruments for X and gamma radiation measurement
Ionising radiation rate meters
Calibration — Dosimetric quantities
air kerma rate (Co-60) — μGy/h to Gy/h · CMC 3 % air kerma rate (Cs-137) — μGy/h to mGy/h · CMC 3 % exposure rate (Co-60, Cs-137) — μR/h to R/h · CMC 3 % absorbed dose rate in air (Co-60) — μGy/h to Gy/h · CMC 3 % absorbed dose rate in air (Cs-137) — μGy/h to mGy/h · CMC 3 % ambient dose equivalent rate (Co-60) — μSv/h to Sv/h · CMC 5 % ambient dose equivalent rate (Cs-137) — μSv/h to mSv/h · CMC 5 % personal dose equivalent rate (Co-60) — μSv/h to Sv/h · CMC 5 % personal dose equivalent rate (Cs-137) — μSv/h to mSv/h · CMC 5 % air kerma (Co-60, Cs-137) — μGy to Gy · CMC 3 % exposure (Co-60, Cs-137) — mR to R · CMC 3 % absorbed dose in air (Co-60, Cs-137) — μGy to Gy · CMC 3 % ambient dose equivalent (Co-60, Cs-137) — μSv to Sv · CMC 5 % personal dose equivalent (Co-60, Cs-137) — μSv to Sv · CMC 5 %
Dosimetric quantities
Internal procedure; At permanent location (S) ILW-04 ILW-05
2 Calibration benches Calibration — Dosimetric quantities
air kerma rate (Co-60) — μGy/h to Gy/h · CMC 1,5 % air kerma rate (Cs-137) — μGy/h to mGy/h · CMC 1,5 %
Dosimetric quantities
Internal procedure; At permanent location (S) ILW-01

Reference standards (3)

ILW-01
ILW-04
ILW-05