🇵🇱 Biuro Techniczne Hałat P.U.H. Iwona Hałat-Czajkowska PL

PCA AP 099 • Andrychów, Poland • 6 calibration items

Metrology & calibration

Biuro Techniczne Hałat P.U.H. Iwona Hałat-Czajkowska is a calibration laboratory accredited by PCA under number AP 099 (Andrychów, Poland). Its accreditation scope covers 6 calibration items in the following areas: Metrology & calibration. Calibrated items include: CNC coordinate measuring machines with a contact probe (with fixed…, CNC coordinate measuring machines with a contact probe (with fixed…, Manual coordinate measuring machines with a contact probe (without…, Scanning contact probes on CNC measuring machines. Most frequently used calibration principles: Internal procedure; Using a test sphere; Outside of permanent locat…, Internal procedure; Using gauge blocks; Outside of permanent locati….

At a glance

  • Accreditation number: PCA AP 099
  • Calibration items in scope: 6
  • Types of calibrated items: 6
  • Calibration principles used: 2
  • City: Andrychów, Poland
  • Valid until: 19-02-2027
Accreditation number
AP 099
Accreditation body
PCA
Address
ul. Tadeusza Wolfa 19a, 34-120 Andrychów
City
Andrychów, Poland
Division
Laboratorium Wzorcujące BTH
Valid until
19-02-2027

What this laboratory calibrates (6)

Calibration principles (2)

Certificate information

Issue date
15.12.2025
Issue no.
20
Certificate date
28.02.2022
Accreditation cycle
08.02.2023 — 19.02.2027
Approved by
Katarzyna Wiśniewska

Accreditation scope — calibration items (6)

The uncertainty covered by the CMC is the expanded uncertainty with a coverage probability of approximately 95 % and is expressed in measurand units. The measurement uncertainty value for CMC expressed as the equation Q[a; b] represents the square root of the sum of the squares of the terms in brackets: Q[a; b] = (a² + b²)^1/2.

No. Calibrated quantity / subject of calibration Nominal range / parameters / CMC Calibration principle Calibration procedure
Calibration items
1 CNC coordinate measuring machines with a contact probe (with fixed table, with temperature compensation) Calibration — Length (coordinate measurements)
25 mm to 1370 mm · CMC Q[0,08; 1,47 · L] μm; L – measured length (m) 1371 mm to 2900 mm · CMC Q[0,21; 1,51 · L] μm; L – measured length (m)
Length (coordinate measurements)
Internal procedure; Using gauge blocks; Outside of permanent location (P) IT 7.4 w oparciu o PN-EN ISO 10360-2:2010
2 CNC coordinate measuring machines with a contact probe (with fixed table, without temperature compensation) Calibration — Length (coordinate measurements)
25 mm to 1370 mm · CMC Q[0,12; 2,23 · L] μm; L – measured length (m) 1371 mm to 2900 mm · CMC Q[0,30; 2,33 · L] μm; L – measured length (m)
Length (coordinate measurements)
Internal procedure; Using gauge blocks; Outside of permanent location (P) IT 7.4 w oparciu o PN-EN ISO 10360-2:2010
3 Touch-trigger contact probes on CNC measuring machines Calibration — Length (coordinate measurements)
25 mm · CMC 0,3 μm
Length (coordinate measurements)
Internal procedure; Using a test sphere; Outside of permanent location (P) IT 7.4 w oparciu o PN-EN ISO 10360-5:2020
4 Scanning contact probes on CNC measuring machines Calibration — Length (coordinate measurements)
25 mm · CMC 0,4 μm
Length (coordinate measurements)
Internal procedure; Using a test sphere; Outside of permanent location (P) IT 7.4 w oparciu o PN-EN ISO 10360-5:2020
5 Manual coordinate measuring machines with a contact probe (without temperature compensation) Calibration — Length (coordinate measurements)
25 mm to 1370 mm · CMC Q[0,91; 3,20 · L] μm; L – measured length (m)
Length (coordinate measurements)
Internal procedure; Using gauge blocks; Outside of permanent location (P) IT 7.4 w oparciu o PN-EN ISO 10360-2:2010
6 Touch-trigger contact probes on manual measuring machines Calibration — Length (coordinate measurements)
25 mm · CMC 0,7 μm
Length (coordinate measurements)
Internal procedure; Using a test sphere; Outside of permanent location (P) IT 7.4 w oparciu o PN-EN ISO 10360-5:2020

Reference standards (3)

IT 7.4
PN-EN ISO 10360-2:2010
PN-EN ISO 10360-5:2020