🇵🇱 ENEA Pomiary Sp. z o.o. PL

PCA AP 095 • Poznań, Poland • 3 calibration items

Metrology & calibration

ENEA Pomiary Sp. z o.o. is a calibration laboratory accredited by PCA under number AP 095 (Poznań, Poland). Its accreditation scope covers 3 calibration items in the following areas: Metrology & calibration. Calibrated items include: Devices for testing electrical energy meters, AC active electrical energy meters, AC reactive electrical energy meters, Current transformers. Most frequently used calibration principles: Internal procedure; Reference meter method; At permanent location (…, Internal procedure; Bridge method; At permanent location (S).

At a glance

  • Accreditation number: PCA AP 095
  • Calibration items in scope: 3
  • Types of calibrated items: 4
  • Calibration principles used: 2
  • City: Poznań, Poland
  • Valid until: 27-04-2030
Accreditation number
AP 095
Accreditation body
PCA
Address
ul. Strzeszyńska 58, 60-479 Poznań
City
Poznań, Poland
Division
Laboratorium Pomiarowe ENEA
Valid until
27-04-2030

What this laboratory calibrates (4)

Calibration principles (2)

Certificate information

Issue date
08.04.2026
Issue no.
20
Certificate date
24.01.2020
Accreditation cycle
08.04.2026 — 27.04.2030
Approved by
Katarzyna Wiśniewska

Accreditation scope — calibration items (3)

The measurement uncertainty value for CMC expressed as a percentage is the relative measurement uncertainty and refers to the percentage share in the measured value.

No. Calibrated quantity / subject of calibration Nominal range / parameters / CMC Calibration principle Calibration procedure
Calibration items
1 AC active electrical energy meters
Devices for testing electrical energy meters
Calibration — Energy
cos φ = 1 or cos φ = - 1 — frequency: 50 Hz; voltage: 30 V to 270 V; phase angle: φ 0° to 360°; current: 0,05 A to 120 A · CMC 0,026 % cos φ = 0,8 or cos φ = - 0,8 — frequency: 50 Hz; voltage: 30 V to 270 V; phase angle: φ 0° to 360°; current: 0,05 A to 120 A · CMC 0,028 % cos φ = 0,5 or cos φ = - 0,5 — frequency: 50 Hz; voltage: 30 V to 270 V; phase angle: φ 0° to 360°; current: 0,05 A to 120 A · CMC 0,052 % cos φ = 1 or cos φ = - 1 — frequency: 50 Hz; voltage: 30 V to 270 V; phase angle: φ 0° to 360°; current: 0,01 A to 0,05 A · CMC 0,029 % cos φ = 0,8 or cos φ = - 0,8 — frequency: 50 Hz; voltage: 30 V to 270 V; phase angle: φ 0° to 360°; current: 0,01 A to 0,05 A · CMC 0,032 % cos φ = 0,5 or cos φ = - 0,5 — frequency: 50 Hz; voltage: 30 V to 270 V; phase angle: φ 0° to 360°; current: 0,01 A to 0,05 A · CMC 0,058 % cos φ = 1 or cos φ = - 1 — frequency: 50 Hz; voltage: 30 V to 270 V; phase angle: φ 0° to 360°; current: 0,001 A to 0,01 A · CMC 0,037 % cos φ = 0,8 or cos φ = - 0,8 — frequency: 50 Hz; voltage: 30 V to 270 V; phase angle: φ 0° to 360°; current: 0,001 A to 0,01 A · CMC 0,043 % cos φ = 0,5 or cos φ = - 0,5 — frequency: 50 Hz; voltage: 30 V to 270 V; phase angle: φ 0° to 360°; current: 0,001 A to 0,01 A · CMC 0,074 %
Energy
Internal procedure; Reference meter method; At permanent location (S) and outside of it (P) P.03/00 P.16/00
2 AC reactive electrical energy meters
Devices for testing electrical energy meters
Calibration — Energy
sin φ = 1 or sin φ = - 1 — frequency: 50 Hz; voltage: 30 V to 270 V; phase angle: φ 0° to 360°; current: 0,05 A to 10 A · CMC 0,026 % sin φ = 0,8 or sin φ = - 0,8 — frequency: 50 Hz; voltage: 30 V to 270 V; phase angle: φ 0° to 360°; current: 0,05 A to 10 A · CMC 0,028 % sin φ = 0,5 or sin φ = - 0,5 — frequency: 50 Hz; voltage: 30 V to 270 V; phase angle: φ 0° to 360°; current: 0,05 A to 10 A · CMC 0,052 % sin φ = 1 or sin φ = - 1 — frequency: 50 Hz; voltage: 30 V to 270 V; phase angle: φ 0° to 360°; current: 0,01 A to 0,05 A · CMC 0,029 % sin φ = 0,8 or sin φ = - 0,8 — frequency: 50 Hz; voltage: 30 V to 270 V; phase angle: φ 0° to 360°; current: 0,01 A to 0,05 A · CMC 0,032 % sin φ = 0,5 or sin φ = - 0,5 — frequency: 50 Hz; voltage: 30 V to 270 V; phase angle: φ 0° to 360°; current: 0,01 A to 0,05 A · CMC 0,058 % sin φ = 1 or sin φ = - 1 — frequency: 50 Hz; voltage: 30 V to 270 V; phase angle: φ 0° to 360°; current: 0,001 A to 0,01 A · CMC 0,037 % sin φ = 0,8 or sin φ = - 0,8 — frequency: 50 Hz; voltage: 30 V to 270 V; phase angle: φ 0° to 360°; current: 0,001 A to 0,01 A · CMC 0,043 % sin φ = 0,5 or sin φ = - 0,5 — frequency: 50 Hz; voltage: 30 V to 270 V; phase angle: φ 0° to 360°; current: 0,001 A to 0,01 A · CMC 0,074 %
Energy
Internal procedure; Reference meter method; At permanent location (S) and outside of it (P) P.03/00 P.16/00
3 Current transformers Calibration — High voltage and current
ratio of alternating currents (50 Hz) — 5 A to 5000 A / 5 A / 1 A; 1 % to 120 % of primary current · CMC 0,038 %; 2,3 min
High voltage and current
Internal procedure; Bridge method; At permanent location (S) P.17/00

Reference standards (3)

P.03/00
P.16/00
P.17/00