🇵🇱 ENEA Pomiary Sp. z o.o. PL
Metrology & calibration
ENEA Pomiary Sp. z o.o. is a calibration laboratory accredited by PCA under number AP 095 (Poznań, Poland). Its accreditation scope covers 3 calibration items in the following areas: Metrology & calibration. Calibrated items include: Devices for testing electrical energy meters, AC active electrical energy meters, AC reactive electrical energy meters, Current transformers. Most frequently used calibration principles: Internal procedure; Reference meter method; At permanent location (…, Internal procedure; Bridge method; At permanent location (S).
At a glance
- Accreditation number: PCA AP 095
- Calibration items in scope: 3
- Types of calibrated items: 4
- Calibration principles used: 2
- City: Poznań, Poland
- Valid until: 27-04-2030
- Accreditation number
- AP 095
- Accreditation body
- PCA
- Address
- ul. Strzeszyńska 58, 60-479 Poznań
- City
- Poznań, Poland
- Division
- Laboratorium Pomiarowe ENEA
- Valid until
- 27-04-2030
What this laboratory calibrates (4)
- Devices for testing electrical energy meters — 2 calibration items
- AC active electrical energy meters — 1 calibration item
- AC reactive electrical energy meters — 1 calibration item
- Current transformers — 1 calibration item
Calibration principles (2)
- Internal procedure; Reference meter method; At permanent location (S) and outside of it (P) — 2 calibration items
- Internal procedure; Bridge method; At permanent location (S) — 1 calibration item
Certificate information
- Issue date
- 08.04.2026
- Issue no.
- 20
- Certificate date
- 24.01.2020
- Accreditation cycle
- 08.04.2026 — 27.04.2030
- Approved by
- Katarzyna Wiśniewska
Accreditation scope — calibration items (3)
| No. | Calibrated quantity / subject of calibration | Nominal range / parameters / CMC | Calibration principle | Calibration procedure | |
|---|---|---|---|---|---|
| Calibration items | |||||
| 1 | AC active electrical energy meters Devices for testing electrical energy meters |
Calibration — Energy cos φ = 1 or cos φ = - 1 — frequency: 50 Hz; voltage: 30 V to 270 V; phase angle: φ 0° to 360°; current: 0,05 A to 120 A · CMC 0,026 % cos φ = 0,8 or cos φ = - 0,8 — frequency: 50 Hz; voltage: 30 V to 270 V; phase angle: φ 0° to 360°; current: 0,05 A to 120 A · CMC 0,028 % cos φ = 0,5 or cos φ = - 0,5 — frequency: 50 Hz; voltage: 30 V to 270 V; phase angle: φ 0° to 360°; current: 0,05 A to 120 A · CMC 0,052 % cos φ = 1 or cos φ = - 1 — frequency: 50 Hz; voltage: 30 V to 270 V; phase angle: φ 0° to 360°; current: 0,01 A to 0,05 A · CMC 0,029 % cos φ = 0,8 or cos φ = - 0,8 — frequency: 50 Hz; voltage: 30 V to 270 V; phase angle: φ 0° to 360°; current: 0,01 A to 0,05 A · CMC 0,032 % cos φ = 0,5 or cos φ = - 0,5 — frequency: 50 Hz; voltage: 30 V to 270 V; phase angle: φ 0° to 360°; current: 0,01 A to 0,05 A · CMC 0,058 % cos φ = 1 or cos φ = - 1 — frequency: 50 Hz; voltage: 30 V to 270 V; phase angle: φ 0° to 360°; current: 0,001 A to 0,01 A · CMC 0,037 % cos φ = 0,8 or cos φ = - 0,8 — frequency: 50 Hz; voltage: 30 V to 270 V; phase angle: φ 0° to 360°; current: 0,001 A to 0,01 A · CMC 0,043 % cos φ = 0,5 or cos φ = - 0,5 — frequency: 50 Hz; voltage: 30 V to 270 V; phase angle: φ 0° to 360°; current: 0,001 A to 0,01 A · CMC 0,074 % Energy |
Internal procedure; Reference meter method; At permanent location (S) and outside of it (P) | P.03/00 P.16/00 | |
| 2 | AC reactive electrical energy meters Devices for testing electrical energy meters |
Calibration — Energy sin φ = 1 or sin φ = - 1 — frequency: 50 Hz; voltage: 30 V to 270 V; phase angle: φ 0° to 360°; current: 0,05 A to 10 A · CMC 0,026 % sin φ = 0,8 or sin φ = - 0,8 — frequency: 50 Hz; voltage: 30 V to 270 V; phase angle: φ 0° to 360°; current: 0,05 A to 10 A · CMC 0,028 % sin φ = 0,5 or sin φ = - 0,5 — frequency: 50 Hz; voltage: 30 V to 270 V; phase angle: φ 0° to 360°; current: 0,05 A to 10 A · CMC 0,052 % sin φ = 1 or sin φ = - 1 — frequency: 50 Hz; voltage: 30 V to 270 V; phase angle: φ 0° to 360°; current: 0,01 A to 0,05 A · CMC 0,029 % sin φ = 0,8 or sin φ = - 0,8 — frequency: 50 Hz; voltage: 30 V to 270 V; phase angle: φ 0° to 360°; current: 0,01 A to 0,05 A · CMC 0,032 % sin φ = 0,5 or sin φ = - 0,5 — frequency: 50 Hz; voltage: 30 V to 270 V; phase angle: φ 0° to 360°; current: 0,01 A to 0,05 A · CMC 0,058 % sin φ = 1 or sin φ = - 1 — frequency: 50 Hz; voltage: 30 V to 270 V; phase angle: φ 0° to 360°; current: 0,001 A to 0,01 A · CMC 0,037 % sin φ = 0,8 or sin φ = - 0,8 — frequency: 50 Hz; voltage: 30 V to 270 V; phase angle: φ 0° to 360°; current: 0,001 A to 0,01 A · CMC 0,043 % sin φ = 0,5 or sin φ = - 0,5 — frequency: 50 Hz; voltage: 30 V to 270 V; phase angle: φ 0° to 360°; current: 0,001 A to 0,01 A · CMC 0,074 % Energy |
Internal procedure; Reference meter method; At permanent location (S) and outside of it (P) | P.03/00 P.16/00 | |
| 3 | Current transformers | Calibration — High voltage and current ratio of alternating currents (50 Hz) — 5 A to 5000 A / 5 A / 1 A; 1 % to 120 % of primary current · CMC 0,038 %; 2,3 min High voltage and current |
Internal procedure; Bridge method; At permanent location (S) | P.17/00 | |
Reference standards (3)
P.03/00
P.16/00
P.17/00