🇵🇱 ENERGO-MOC Wzorcownia Sp. z o.o. PL
Metrology & calibration
ENERGO-MOC Wzorcownia Sp. z o.o. is a calibration laboratory accredited by PCA under number AP 094 (Gliwice, Poland). Its accreditation scope covers 2 calibration items in the following areas: Metrology & calibration. Calibrated items include: AC active electrical energy meters, AC reactive electrical energy meters. Most frequently used calibration principles: Internal procedure; Calibration by the reference meter method; At p….
At a glance
- Accreditation number: PCA AP 094
- Calibration items in scope: 2
- Types of calibrated items: 2
- Calibration principles used: 1
- City: Gliwice, Poland
- Valid until: 27-04-2030
- Accreditation number
- AP 094
- Accreditation body
- PCA
- Address
- ul. Metalowców 15, 44-109 Gliwice
- City
- Gliwice, Poland
- Division
- Laboratorium Liczników Energii Elektrycznej
- Valid until
- 27-04-2030
What this laboratory calibrates (2)
- AC active electrical energy meters — 1 calibration item
- AC reactive electrical energy meters — 1 calibration item
Calibration principles (1)
- Internal procedure; Calibration by the reference meter method; At permanent location (S) — 2 calibration items
Certificate information
- Issue date
- 01.04.2026
- Issue no.
- 18
- Certificate date
- 10.03.2020
- Accreditation cycle
- 01.04.2026 — 27.04.2030
- Approved by
- Katarzyna Wiśniewska
Accreditation scope — calibration items (2)
| No. | Calibrated quantity / subject of calibration | Nominal range / parameters / CMC | Calibration principle | Calibration procedure | |
|---|---|---|---|---|---|
| Calibration items | |||||
| 1 | AC active electrical energy meters | Calibration — Energy cos φ = 1 or cos φ = -1 — 50 Hz; 30 V to 300 V; 0,01 A to 120 A · CMC 0,058 % cos φ = 0,8 or cos φ = -0,8 — 50 Hz; 30 V to 300 V; 0,01 A to 120 A · CMC 0,058 % cos φ = 0,5 or cos φ = -0,5 — 50 Hz; 30 V to 300 V; 0,01 A to 120 A · CMC 0,058 % cos φ = 0,25 or cos φ = -0,25 — 50 Hz; 30 V to 300 V; 0,01 A to 120 A · CMC 0,23 % Energy |
Internal procedure; Calibration by the reference meter method; At permanent location (S) | PLW-24 | |
| 2 | AC reactive electrical energy meters | Calibration — Energy sin φ = 1 or sin φ = -1 — 50 Hz; 30 V to 300 V; 0,01 A to 120 A · CMC 0,058 % sin φ = 0,8 or sin φ = -0,8 — 50 Hz; 30 V to 300 V; 0,01 A to 120 A · CMC 0,058 % sin φ = 0,5 or sin φ = -0,5 — 50 Hz; 30 V to 300 V; 0,01 A to 120 A · CMC 0,058 % sin φ = 0,25 or sin φ = -0,25 — 50 Hz; 30 V to 300 V; 0,01 A to 120 A · CMC 0,23 % Energy |
Internal procedure; Calibration by the reference meter method; At permanent location (S) | PLW-24 | |
Reference standards (1)
PLW-24