🇵🇱 TOPS S.C. Krzysztof Ziomek, Piotr Sierek PL

PCA AP 093 • Czechowice Dziedzice, Poland • 9 calibration items

Metrology & calibration

TOPS S.C. Krzysztof Ziomek, Piotr Sierek is a calibration laboratory accredited by PCA under number AP 093 (Czechowice Dziedzice, Poland). Its accreditation scope covers 9 calibration items in the following areas: Metrology & calibration. Calibrated items include: Mass standards, Load weights, Mass standards and weights of accuracy class F₁, Mass standards and weights of accuracy class F₂. Most frequently used calibration principles: Internal procedure; At permanent location (S), Internal procedure; At permanent location (S) and outside of it (P).

At a glance

  • Accreditation number: PCA AP 093
  • Calibration items in scope: 9
  • Types of calibrated items: 9
  • Calibration principles used: 2
  • City: Czechowice Dziedzice, Poland
  • Valid until: 09-02-2030
Accreditation number
AP 093
Accreditation body
PCA
Address
ul. Legionów 239a, 43-502 Czechowice Dziedzice
City
Czechowice Dziedzice, Poland
Division
Mass Measurement Laboratory
Valid until
09-02-2030

What this laboratory calibrates (9)

Calibration principles (2)

Certificate information

Issue date
05.03.2026
Issue no.
16
Certificate date
24.01.2020
Accreditation cycle
14.01.2026 — 09.02.2030
Approved by
Katarzyna Wiśniewska

Accreditation scope — calibration items (9)

The uncertainty covered by the CMC is the expanded uncertainty with a coverage probability of approximately 95 % and is expressed in measurand units. A CMC uncertainty value expressed as a percentage is the relative measurement uncertainty and refers to the percentage of the value of the measurand.

No. Calibrated quantity / subject of calibration Nominal range / parameters / CMC Calibration principle Calibration procedure
Calibration items
1 Non-automatic electronic weighing instruments
Non-automatic mechanical weighing instruments
Calibration — Mass (weighing instruments)
up to 400 g · CMC 5 · 10⁻⁵ % 400 g to20 kg · CMC 2,6 · 10⁻⁴ % 20 kg to 75 kg · CMC 6,2 · 10⁻⁴ % 75 kg to 5000 kg · CMC 1,1 · 10⁻² %
Mass (weighing instruments)
Internal procedure; At permanent location (S) and outside of it (P) PTW-01 based on EURAMET cg-18 v.4.0
2 Mass standards and weights of accuracy class F₁ Calibration — Mass (weights and mass standards)
1 mg · CMC 0,006 mg 2 mg · CMC 0,006 mg 5 mg · CMC 0,006 mg 10 mg · CMC 0,008 mg 20 mg · CMC 0,010 mg 50 mg · CMC 0,012 mg 100 mg · CMC 0,016 mg 200 mg · CMC 0,020 mg 500 mg · CMC 0,025 mg 1 g · CMC 0,03 mg 2 g · CMC 0,04 mg 5 g · CMC 0,05 mg 10 g · CMC 0,06 mg 20 g · CMC 0,08 mg 50 g · CMC 0,10 mg 100 g · CMC 0,16 mg 200 g · CMC 0,3 mg 500 g · CMC 0,8 mg 1 kg · CMC 1,6 mg 2 kg · CMC 3,0 mg 5 kg · CMC 8,0 mg 10 kg · CMC 16 mg
Mass (weights and mass standards)
Internal procedure; At permanent location (S) PTW-03 based on OIML R 111-1:2004 Annex C
3 Mass standards and weights of accuracy class F₂ Calibration — Mass (weights and mass standards)
1 mg · CMC 0,020 mg 2 mg · CMC 0,020 mg 5 mg · CMC 0,020 mg 10 mg · CMC 0,025 mg 20 mg · CMC 0,03 mg 50 mg · CMC 0,04 mg 100 mg · CMC 0,05 mg 200 mg · CMC 0,06 mg 500 mg · CMC 0,08 mg 1 g · CMC 0,10 mg 2 g · CMC 0,12 mg 5 g · CMC 0,16 mg 10 g · CMC 0,20 mg 20 g · CMC 0,25 mg 50 g · CMC 0,3 mg 100 g · CMC 0,5 mg 200 g · CMC 1,0 mg 500 g · CMC 2,5 mg 1 kg · CMC 5,0 mg 2 kg · CMC 10 mg 5 kg · CMC 25 mg 10 kg · CMC 50 mg 20 kg · CMC 100 mg
Mass (weights and mass standards)
Internal procedure; At permanent location (S) PTW-03 based on OIML R 111-1:2004 Annex C
4 Mass standards and weights of accuracy class M₁ Calibration — Mass (weights and mass standards)
1 mg · CMC 0,06 mg 2 mg · CMC 0,06 mg 5 mg · CMC 0,06 mg 10 mg · CMC 0,08 mg 20 mg · CMC 0,10 mg 50 mg · CMC 0,12 mg 100 mg · CMC 0,16 mg 200 mg · CMC 0,20 mg 500 mg · CMC 0,25 mg 1 g · CMC 0,3 mg 2 g · CMC 0,4 mg 5 g · CMC 0,5 mg 10 g · CMC 0,6 mg 20 g · CMC 0,8 mg 50 g · CMC 1,0 mg 100 g · CMC 1,6 mg 200 g · CMC 3,0 mg 500 g · CMC 8,0 mg 1 kg · CMC 16 mg 2 kg · CMC 30 mg 5 kg · CMC 80 mg 10 kg · CMC 160 mg 20 kg · CMC 300 mg
Mass (weights and mass standards)
Internal procedure; At permanent location (S) PTW-03 based on OIML R 111-1:2004 Annex C
5 Mass standards and weights of accuracy class M₂ Calibration — Mass (weights and mass standards)
100 mg · CMC 0,5 mg 200 mg · CMC 0,6 mg 500 mg · CMC 0,8 mg 1 g · CMC 1,0 mg 2 g · CMC 1,2 mg 5 g · CMC 1,6 mg 10 g · CMC 2,0 mg 20 g · CMC 2,5 mg 50 g · CMC 3 mg 100 g · CMC 5 mg 200 g · CMC 10 mg 500 g · CMC 25 mg 1 kg · CMC 50 mg 2 kg · CMC 100 mg 5 kg · CMC 250 mg 10 kg · CMC 500 mg 20 kg · CMC 1000 mg
Mass (weights and mass standards)
Internal procedure; At permanent location (S) PTW-03 based on OIML R 111-1:2004 Annex C
6 Mass standards and weights of accuracy class M₃ Calibration — Mass (weights and mass standards)
1 g · CMC 3,0 mg 2 g · CMC 4,0 mg 5 g · CMC 5,0 mg 10 g · CMC 6,0 mg 20 g · CMC 8,0 mg 50 g · CMC 10 mg 100 g · CMC 16 mg 200 g · CMC 30 mg 500 g · CMC 80 mg 1 kg · CMC 160 mg 2 kg · CMC 300 mg 5 kg · CMC 800 mg 10 kg · CMC 1600 mg 20 kg · CMC 3000 mg
Mass (weights and mass standards)
Internal procedure; At permanent location (S) PTW-03 based on OIML R 111-1:2004 Annex C
7 Mass standards Calibration — Mass (weights and mass standards)
25 kg · CMC 125 mg
Mass (weights and mass standards)
Internal procedure; At permanent location (S) PTW-03 based on OIML R 111-1:2004 Annex C
8 Mass standards Calibration — Mass (weights and mass standards)
25 kg · CMC 350 mg
Mass (weights and mass standards)
Internal procedure; At permanent location (S) and outside of it (P) PTW-03 based on OIML R 111-1:2004 Annex C
9 Load weights Calibration — Mass (weights and mass standards)
up to 10 kg · CMC 1,6·10⁻⁴ % 10 kg to 25 kg · CMC 5·10⁻⁴ %
Mass (weights and mass standards)
Internal procedure; At permanent location (S) PTW-03 based on OIML R 111-1:2004 Annex C

Reference standards (4)

EURAMET cg-18 v.4.0
OIML R 111-1:2004 Załącznik C
PTW-01
PTW-03

The same scope as data (JSON): https://labcoda.pl/api/accreditation-scopes/labs/PL/AP%20093