🇵🇱 Okręgowy Urząd Miar w Katowicach PL

PCA AP 085 • Katowice, Poland • 25 calibration items

Metrology & calibration

Okręgowy Urząd Miar w Katowicach is a calibration laboratory accredited by PCA under number AP 085 (Katowice, Poland). Its accreditation scope covers 25 calibration items in the following areas: Metrology & calibration. Calibrated items include: Calibrators, Multimeters, Analogue ammeters, Analogue voltmeters. Most frequently used calibration principles: Internal procedure; At permanent location (S), Internal procedure; Direct method; At permanent location (S), Internal procedure; At permanent location (S) and outside of it (P).

At a glance

  • Accreditation number: PCA AP 085
  • Calibration items in scope: 25
  • Types of calibrated items: 27
  • Calibration principles used: 5
  • City: Katowice, Poland
  • Valid until: 18-01-2030
Accreditation number
AP 085
Accreditation body
PCA
Address
ul. Rynek 9, 40-957 Katowice
City
Katowice, Poland
Division
Calibration Laboratories Group
Valid until
18-01-2030

What this laboratory calibrates (27)

Calibration principles (5)

Certificate information

Issue date
19.12.2025
Issue no.
19
Certificate date
13.08.2020
Accreditation cycle
19.12.2025 — 18.01.2030
Approved by
Katarzyna Wiśniewska

Accreditation scope — calibration items (25)

The uncertainty covered by the CMC is the expanded uncertainty with a coverage probability of approximately 95 %. A value expressed as a percentage is the relative measurement uncertainty and refers to the percentage of the value of the measurand. In other cases, the CMC uncertainty is expressed in measurand units.

No. Calibrated quantity / subject of calibration Nominal range / parameters / CMC Calibration principle Calibration procedure
Calibration items
1 Gauge blocks (classes 0, 1, 2) Calibration — Length
0,46 mm to 100 mm · CMC Q[57; 1,9·L] nm
Length
Internal procedure; Comparison method in vertical arrangement; At permanent location (S) I/W1/09/01
2 Gauge blocks (classes 0, 1, 2) Calibration — Length
125 mm to 500 mm · CMC Q[95; 2,0·L] nm
Length
Internal procedure; Comparison method in vertical arrangement; At permanent location (S) I/W1/09/01
3 Johansson angle gauge blocks
Kusznikow angle gauge blocks
Wringing angle gauge blocks
Calibration — Angle
180° · CMC 3,7”
Angle
Internal procedure; At permanent location (S) I/W1/09/03
4 Electronic pressure gauges
Spring pressure gauges
Calibration — Pressure
- gauge pressure: gas — - 0,003 MPa to - 0,1 MPa · CMC 5 · 10⁻⁶ MPa - gauge pressure: gas — 0,001 MPa to 0,1 MPa · CMC 5 · 10⁻⁶ MPa - gauge pressure: gas — >0,1 MPa to 3,5 MPa · CMC 6 · 10⁻⁵ MPa
Pressure
Internal procedure; At permanent location (S) I/W1/09/12 I/W1/09/12a I/W1/09/12b I/W1/09/12c I/W1/09/12d I/W1/09/12e
5 Electronic pressure gauges
Spring pressure gauges
Calibration — Pressure
- gauge pressure: liquid — 0,02 MPa to 0,6 MPa · CMC 5 · 10⁻⁴ MPa - gauge pressure: liquid — >0,6 MPa to 6,0 MPa · CMC 1 · 10⁻³ MPa - gauge pressure: liquid — >6,0 MPa to 100,0 MPa · CMC 2 · 10⁻² MPa
Pressure
Internal procedure; At permanent location (S) I/W1/09/12 I/W1/09/12a I/W1/09/12b I/W1/09/12c I/W1/09/12d I/W1/09/12e
6 pH meters Calibration — pH
- pH — 0 to 14 · CMC 0,002 - DC voltage — -1900 mV to 1900 mV · CMC 0,2 mV
pH
Internal procedure; Electrical method; At permanent location (S) I/W3/09/01
7 Conductometers Calibration — Specific electrical conductivity (conductometry)
0,2 µS/cm to 2 µS/cm · CMC 0,3 % 0,002 mS/cm to 200 mS/cm · CMC 0,2 %
Specific electrical conductivity (conductometry)
Internal procedure; Electrical method; At permanent location (S) I/W3/09/13
8 Calibrators Calibration — DC voltage
10 mV to 1000 V · CMC 0,003 %
DC voltage
Internal procedure; Direct method; At permanent location (S) I/W3/09/12
9 Analogue voltmeters
Digital voltmeters
Multimeters
Calibration — DC voltage
0,2 mV to 2 mV · CMC 0,5 % 2 mV to 20 mV · CMC 0,1 % 20 mV to 200 mV · CMC 0,01 % 0,2 V to 1000 V · CMC 0,005 %
DC voltage
Internal procedure; Direct method; At permanent location (S) I/W3/09/03 I/W3/09/10
10 Calibrators Calibration — DC current
10 µA to 200 mA · CMC 0,007 % 200 mA to 2 A · CMC 0,03 % 2 A to 10 A · CMC 0,08 %
DC current
Internal procedure; Direct method; At permanent location (S) I/W3/09/12
11 Analogue ammeters
Digital ammeters
Multimeters
Calibration — DC current
0,2 mA to 200 mA · CMC 0,03 % 0,2 A to 2 A · CMC 0,07 % 2 A to 10 A · CMC 0,15 %
DC current
Internal procedure; Direct method; At permanent location (S) I/W3/09/03 I/W3/09/10
12 Calibrators Calibration — AC voltage
40 Hz to 10 kHz — 10 mV to 1000 V · CMC 0,02 %
AC voltage
Internal procedure; Direct method; At permanent location (S) I/W3/09/12
13 Analogue voltmeters
Digital voltmeters
Multimeters
Calibration — AC voltage
40 Hz to 20 kHz — 0,2 mV to 2 mV · CMC 1% 40 Hz to 20 kHz — 2 mV to 20 mV · CMC 0,2 % 40 Hz to 20 kHz — 20 mV to 200 mV · CMC 0,1 % 40 Hz to 20 kHz — 0,2 V to 200 V · CMC 0,07 % 40 Hz to 5 kHz — 200 V to 1000 V · CMC 0,07 %
AC voltage
Internal procedure; Direct method; At permanent location (S) I/W3/09/03 I/W3/09/10
14 Calibrators Calibration — AC current
40 Hz to 10 kHz — 10 µA to 200 µA · CMC 0,1 % 40 Hz to 10 kHz — 0,2 mA to 200 mA · CMC 0,06 % 40 Hz to 2 kHz — 0,2 A to 2 A · CMC 0,1 % 40 Hz to 2 kHz — 2 A to 10 A · CMC 0,2 % 2 kHz to 10 kHz — 2 A to 10 A · CMC 0,4 %
AC current
Internal procedure; Direct method; At permanent location (S) I/W3/09/12
15 Analogue ammeters
Digital ammeters
Multimeters
Calibration — AC current
40 Hz to 5 kHz — 0,2 mA to 200 mA · CMC 0,1 % 40 Hz to 5 kHz — 0,2 A to 2 A · CMC 0,15 % 40 Hz to 1 kHz — 2 A to 10 A · CMC 0,3 %
AC current
Internal procedure; Direct method; At permanent location (S) I/W3/09/03 I/W3/09/10
16 Fixed resistors
Variable resistors
Digital ohmmeters
Calibrators
Calibration — DC resistance
0,001 Ω to 1 Ω · CMC 0,005 % 1 Ω to 100 MΩ · CMC 0,003 % 100 MΩ to 1 GΩ · CMC 0,01 %
DC resistance
Internal procedure; Direct method; At permanent location (S) I/W3/09/03 I/W3/09/04 I/W3/09/06 I/W3/09/12
17 Mechanical stopwatches Calibration — Time (time interval)
0 h to 1 h · CMC 5·10⁻⁵·τ + 0,06 s
Time (time interval)
Internal procedure; At permanent location (S) I/W3/09/11
18 Electronic stopwatches Calibration — Time (time interval)
0 h to 24 h · CMC 6·10⁻⁷·τ + 0,02 s
Time (time interval)
Internal procedure; At permanent location (S) I/W3/09/05
19 Period meters
Period generators
Calibration — Time (time interval)
0,75 ns to 10 s · CMC (15 µHz ·T +1,2·10⁻⁹)·T 5 ns to 10 s · CMC (15 µHz ·T +1,2·10⁻⁹)·T
Time (time interval)
Internal procedure; At permanent location (S) I/W3/09/09 I/W3/09/14
20 Time interval meters
Time interval generator
Calibration — Time (time interval)
20 ns to 2000 s · CMC 1,2·10⁻⁹·τ + 10 ns
Time (time interval)
Internal procedure; At permanent location (S) I/W3/09/09 I/W3/09/14
21 Digital timing machines (chronocomparators) Calibration — Time (time interval)
-120 s/d to 120 s/d · CMC 0,7·Δ₁ s/d
Time (time interval)
Internal procedure; At permanent location (S) I/W3/09/08
22 Frequency meters Calibration — Frequency
0,1 Hz to 1,35 GHz · CMC 1,2·10⁻⁹ · f + 15 µHz
Frequency
Internal procedure; At permanent location (S) I/W3/09/09
23 Quartz generators Calibration — Frequency
0,1 Hz to 10 kHz · CMC 15 µHz + 1,2·10⁻⁹·f 10 kHz to 350 MHz · CMC 1,2 · 10⁻⁹·f
Frequency
Internal procedure; At permanent location (S) I/W3/09/14
24 Spectrophotometers Calibration — Optical density of spectral transmittance
filter PDC Blank — 0,0352 for λ=350nm · CMC 0,0035 filter PDC Blank — 0,0366 for λ=313nm · CMC 0,0035 filter PDC Blank — 0,0411 for λ=257nm · CMC 0,0035 filter PDC Blank — 0,0455 for λ=235nm · CMC 0,0035 filter PDC 20 mg/l — 0,2489 for λ=350nm · CMC 0,0039 filter PDC 20 mg/l — 0,1352 for λ=313nm · CMC 0,0039 filter PDC 20 mg/l — 0,3286 for λ=257nm · CMC 0,0039 filter PDC 20 mg/l — 0,2946 for λ=235nm · CMC 0,0039 filter PDC 40mg/l — 0,4500 for λ=350nm · CMC 0,0044 filter PDC 40mg/l — 0,2255 for λ=313nm · CMC 0,0044 filter PDC 40mg/l — 0,6014 for λ=257nm · CMC 0,0044 filter PDC 40mg/l — 0,5284 for λ=257nm · CMC 0,0044 filter PDC 60mg/l — 0,6656 for λ=350nm · CMC 0,0050 filter PDC 60mg/l — 0,3219 for λ=313nm · CMC 0,0050 filter PDC 60mg/l — 0,8912 for λ=257nm · CMC 0,0050 filter PDC 60mg/l — 0,7774 for λ=235nm · CMC 0,0050 filter PDC 80mg/l — 0,8811 for λ=350nm · CMC 0,0058 filter PDC 80mg/l — 0,4214 for λ=313nm · CMC 0,0058 filter PDC 80mg/l — 1,1854 for λ=257nm · CMC 0,0058 filter PDC 80mg/l — 1,0314 for λ=235nm · CMC 0,0058 filter PDC 100mg/l — 1,0975 for λ=350nm · CMC 0,0079 filter PDC 100mg/l — 0,5173 for λ=313nm · CMC 0,0079 filter PDC 100mg/l — 1,4809 for λ=257nm · CMC 0,0079 filter PDC 100mg/l — 1,2844 for λ=235nm · CMC 0,0079 0 to 0,2 · CMC 0,0038 0,2 to 0,5 · CMC 0,0041 0,5 to 1 · CMC 0,0059
Optical density of spectral transmittance
Internal procedure; At permanent location (S) and outside of it (P) I/W3/09/02
25 Spectrophotometers Calibration — Spectral transmittance
filter PDC Blank — 0,9222 for λ=350nm · CMC 0,0064 filter PDC Blank — 0,9192 for λ=313nm · CMC 0,0064 filter PDC Blank — 0,9096 for λ=257nm · CMC 0,0064 filter PDC Blank — 0,9005 for λ=235nm · CMC 0,0064 filter PDC 20 mg/l — 0,5638 for λ=350nm · CMC 0,0055 filter PDC 20 mg/l — 0,7325 for λ=313nm · CMC 0,0055 filter PDC 20 mg/l — 0,4692 for λ=257nm · CMC 0,0055 filter PDC 20 mg/l — 0,5075 for λ=235nm · CMC 0,0055 filter PDC 40mg/l — 0,3548 for λ=350nm · CMC 0,0048 filter PDC 40mg/l — 0,5950 for λ=313nm · CMC 0,0048 filter PDC 40mg/l — 0,2504 for λ=257nm · CMC 0,0048 filter PDC 40mg/l — 0,2962 for λ=235nm · CMC 0,0048 filter PDC 60mg/l — 0,2160 for λ=350nm · CMC 0,0042 filter PDC 60mg/l — 0,4766 for λ=313nm · CMC 0,0042 filter PDC 60mg/l — 0,1285 for λ=257nm · CMC 0,0042 filter PDC 60mg/l — 0,1669 for λ=235nm · CMC 0,0042 filter PDC 80mg/l — 0,1315 for λ=350nm · CMC 0,0037 filter PDC 80mg/l — 0,3790 for λ=313nm · CMC 0,0037 filter PDC 80mg/l — 0,0653 for λ=257nm · CMC 0,0037 filter PDC 80mg/l — 0,0930 for λ=235nm · CMC 0,0037 filter PDC 100mg/l — 0,0799 for λ=350nm · CMC 0,0032 filter PDC 100mg/l — 0,3039 for λ=313nm · CMC 0,0032 filter PDC 100mg/l — 0,0330 for λ=257nm · CMC 0,0032 filter PDC 100mg/l — 0,0520 for λ=235nm · CMC 0,0032 0,1 to 0,3 · CMC 0,0030 0,3 to 0,6 · CMC 0,0040 0,6 to 1 · CMC 0,0050 - wavelength — 270 nm to 780 nm · CMC 0,2 nm
Spectral transmittance
Internal procedure; At permanent location (S) and outside of it (P) I/W3/09/02

Reference standards (21)

I/W1/09/01
I/W1/09/03
I/W1/09/12
I/W1/09/12a
I/W1/09/12b
I/W1/09/12c
I/W1/09/12d
I/W1/09/12e
I/W3/09/01
I/W3/09/02
I/W3/09/03
I/W3/09/04
I/W3/09/05
I/W3/09/06
I/W3/09/08
I/W3/09/09
I/W3/09/10
I/W3/09/11
I/W3/09/12
I/W3/09/13
I/W3/09/14

The same scope as data (JSON): https://labcoda.pl/api/accreditation-scopes/labs/PL/AP%20085