Metrology & calibration
Okręgowy Urząd Miar we Wrocławiu is a calibration laboratory accredited by PCA under number AP 083 (Wrocław, Poland). Its accreditation scope covers 56 calibration items in the following areas: Metrology & calibration. Calibrated items include: Calibrators, Multimeters, Sound level meters, Bridges. Most frequently used calibration principles: Internal procedure; At permanent location (S), Internal procedure; Direct method; At permanent location (S), Internal procedure; Direct method using gauge blocks; At permanent….
At a glance
- Accreditation number: PCA AP 083
- Calibration items in scope: 56
- Types of calibrated items: 59
- Calibration principles used: 10
- City: Wrocław, Poland
- Valid until: 18-01-2030
- Accreditation number
- AP 083
- Accreditation body
- PCA
- Address
- ul. Młodych Techników 61/63, 53-647 Wrocław
- City
- Wrocław, Poland
- Division
- Calibration Laboratories Group
- Valid until
- 18-01-2030
What this laboratory calibrates (59)
- Calibrators — 5 calibration items
- Multimeters — 5 calibration items
- Sound level meters — 4 calibration items
- Bridges — 3 calibration items
- Digital ammeters — 2 calibration items
- Digital ohmmeters — 2 calibration items
- Digital voltmeters — 2 calibration items
- Mass standards of accuracy class M1 — 2 calibration items
- Rigid rules — 2 calibration items
- Semi-rigid rules — 2 calibration items
- Weights of accuracy class M1 — 2 calibration items
- - gauge pressure - negative and positive pressure — 1 calibration item
- - vibration acceleration — 1 calibration item
- 25 kg mass standards — 1 calibration item
- Analogue dial indicators with a scale interval of 0,01 mm — 1 calibration item
- and 44 more
Calibration principles (10)
- Internal procedure; At permanent location (S) — 17 calibration items
- Internal procedure; Direct method; At permanent location (S) — 15 calibration items
- Internal procedure; Direct method using gauge blocks; At permanent location (S) — 8 calibration items
- Internal procedure; Direct method using a micrometer head; At permanent location (S) — 5 calibration items
- Internal procedure; At permanent location (S) and outside of it (P) — 3 calibration items
- Internal procedure; Comparison method using a rigid or semi-rigid rule; At permanent location (S) — 2 calibration items
- Internal procedure; Comparison method using a two-probe comparator; At permanent location (S) — 2 calibration items
- Internal procedure; Electrical method; At permanent location (S) — 2 calibration items
- Internal procedure; Comparison method using gauge blocks and an optimeter; At permanent location (S) — 1 calibration item
- Internal procedure; Using class 1 reference force transducers; Outside of permanent location (P) — 1 calibration item
Certificate information
- Issue date
- 10.11.2026
- Issue no.
- 25
- Certificate date
- 10.01.2020
- Accreditation cycle
- 22.12.2025 — 18.01.2030
- Approved by
- Katarzyna Wiśniewska
Accreditation scope — calibration items (56)
| No. | Calibrated quantity / subject of calibration | Nominal range / parameters / CMC | Calibration principle | Calibration procedure | |
|---|---|---|---|---|---|
| Calibration items | |||||
| 1 | Gauge blocks of class 0 | Calibration — Length 0,5 mm to 100 mm · CMC Q[0,08; 1,2 · L] µm 125 mm to 500 mm · CMC Q[0,08; 1,4 · L] µm Length |
Internal procedure; Comparison method using a two-probe comparator; At permanent location (S) | PW/L1/02 based on PN-EN ISO 3650:2000 | |
| 2 | Gauge blocks 1, 2 | Calibration — Length 0,5 mm to 100 mm · CMC Q[0,10; 1,7 · L] µm 125 mm to 500 mm · CMC Q[0,10; 1,9 · L] µm Length |
Internal procedure; Comparison method using a two-probe comparator; At permanent location (S) | PW/L1/02 based on PN-EN ISO 3650:2000 | |
| 3 | Calipers | Calibration — Length 0 mm to 300 mm · CMC 0,04 mm 300 mm to 500 mm · CMC 0,05 mm Length |
Internal procedure; Direct method using gauge blocks; At permanent location (S) | PW/L1/01 IW1-PW/L1/01 | |
| 4 | Caliper depth gauges | Calibration — Length 0 mm to 500 mm · CMC 0,06 mm Length |
Internal procedure; Direct method using gauge blocks; At permanent location (S) | PW/L1/01 IW1-PW/L1/01 | |
| 5 | Caliper height gauges | Calibration — Length 0 mm to 500 mm · CMC 0,05 mm 500 mm to 800 mm · CMC 0,06 mm 800 mm to 1000 mm · CMC 0,07 mm Length |
Internal procedure; Direct method using gauge blocks; At permanent location (S) | PW/L1/01 IW1-PW/L1/01 | |
| 6 | External micrometers | Calibration — Length 0 mm do 75 mm · CMC 2 µm 75 mm to 100 mm · CMC 3 µm 100 mm do 200 mm · CMC 3 µm Length |
Internal procedure; Direct method using gauge blocks; At permanent location (S) | PW/L1/01 IW2-PW/L1/01 | |
| 7 | Internal micrometers | Calibration — Length 5 mm to 30 mm · CMC 2 µm 30 mm to 55 mm · CMC 2 µm 50 mm to 100 mm · CMC 3 µm 100 mm to 150 mm · CMC 3 µm Length |
Internal procedure; Direct method using gauge blocks; At permanent location (S) | PW/L1/01 IW2-PW/L1/01 | |
| 8 | Micrometers with built-in dial indicator | Calibration — Length 0 mm do 75 mm · CMC 2 µm 75 mm to 100 mm · CMC 2 µm Length |
Internal procedure; Direct method using gauge blocks; At permanent location (S) | PW/L1/01 IW2-PW/L1/01 | |
| 9 | Micrometer depth gauges | Calibration — Length 0 mm to 75 mm · CMC 2 µm 75 mm to 150 mm · CMC 3 µm Length |
Internal procedure; Direct method using gauge blocks; At permanent location (S) | PW/L1/01 IW2-PW/L1/01 | |
| 10 | Indicating snap gauges | Calibration — Length 0 mm to 100 mm · CMC 2 µm Length |
Internal procedure; Direct method using gauge blocks; At permanent location (S) | PW/L1/01 IW2-PW/L1/01 | |
| 11 | Analogue dial indicators with a scale interval of 0,01 mm | Calibration — Length 0 mm to 50 mm · CMC 6 µm Length |
Internal procedure; Direct method using a micrometer head; At permanent location (S) | PW/L1/01 IW3-PW/L1/01 | |
| 12 | Digital indicators with a resolution of 0,01 mm | Calibration — Length 0 mm to 50 mm · CMC 10 µm Length |
Internal procedure; Direct method using a micrometer head; At permanent location (S) | PW/L1/01 IW3-PW/L1/01 | |
| 13 | Digital indicators with a resolution of 0,001 mm | Calibration — Length 0 mm to 50 mm · CMC 3 µm Length |
Internal procedure; Direct method using a micrometer head; At permanent location (S) | PW/L1/01 IW3-PW/L1/01 | |
| 14 | Dial bore gauges with a scale interval of 0,01 mm | Calibration — Length 4 mm to 50 mm · CMC 7 µm 50 mm to 160 mm · CMC 7 µm Length |
Internal procedure; Direct method using a micrometer head; At permanent location (S) | PW/L1/01 IW3-PW/L1/01 | |
| 15 | Dial bore gauges with a scale interval of 0,001 mm | Calibration — Length 18 mm to 35 mm · CMC 2 µm 35 mm to 60 mm · CMC 2 µm 50 mm to 150 mm · CMC 3 µm Length |
Internal procedure; Direct method using a micrometer head; At permanent location (S) | PW/L1/01 IW3-PW/L1/01 | |
| 16 | Feeler gauges | Calibration — Length 0,03 mm to 1,00 mm · CMC 0,8 µm Length |
Internal procedure; Comparison method using gauge blocks and an optimeter; At permanent location (S) | PW/L1/07 | |
| 17 | Rigid rules Semi-rigid rules |
Calibration — Length 0 m to 1 m · CMC 0,08 mm Length |
Internal procedure; Comparison method using a rigid or semi-rigid rule; At permanent location (S) | PW/L1/04 | |
| 18 | Tape measures Rigid rules Semi-rigid rules |
Calibration — Length 0 m to 5 m · CMC (0,08 + 0,01 · L) mm Length |
Internal procedure; Comparison method using a rigid or semi-rigid rule; At permanent location (S) | PW/L1/04 | |
| 19 | Static testing machines for tensile and compressive forces Technological devices for tensile and compressive forces |
Calibration — Force 0,01 N to 2000 kN · CMC 0,25 % Force |
Internal procedure; Using class 1 reference force transducers; Outside of permanent location (P) | PW/L1/15 based on PN-EN ISO 7500-1:2018-05 | |
| 20 | Rockwell hardness testers | Calibration — Hardness hardness — 45 HRA to 88 HRA · CMC 0,6 HRA hardness — 90 HRB to 100 HRB · CMC 0,6 HRB hardness — 20 HRC to 70 HRC · CMC 0,6 HRC force — 98 N to 1471 N · CMC 0,28 % Hardness |
Internal procedure; At permanent location (S) and outside of it (P) | PW/L1/16 based on PN-EN ISO 6508-2:2024-06 | |
| 21 | Non-automatic electronic weighing instruments | Calibration — Mass (weighing instruments) 0 g to 220 g · CMC 2,3·10⁻⁴ % 220 g to 12 kg · CMC 8,5·10⁻⁴ % 12 kg to 300 kg · CMC 6·10⁻³ % Mass (weighing instruments) |
Internal procedure; At permanent location (S) and outside of it (P) | PW/L1/12 based on EURAMET cg-18 v.4.0 | |
| 22 | Mass standards of accuracy class E2 | Calibration — Mass (weights and mass standards) 1g · CMC 0,010 mg 2g · CMC 0,013 mg 5g · CMC 0,016 mg 10 g · CMC 0,020 mg 20 g · CMC 0,026 mg 50 g · CMC 0,03 mg 100 g · CMC 0,05 mg 200 g · CMC 0,10 mg 500 g · CMC 0,25 mg Mass (weights and mass standards) |
Internal procedure; At permanent location (S) | PW/L1/14 based on OIML R-111-1:2004 Annex C | |
| 23 | Mass standards of accuracy class F1 Weights of accuracy class F1 |
Calibration — Mass (weights and mass standards) 1 mg · CMC 0,006 mg 2 mg · CMC 0,006 mg 5 mg · CMC 0,006 mg 10 mg · CMC 0,008 mg 20 mg · CMC 0,010 mg 50 mg · CMC 0,013 mg 100 mg · CMC 0,016 mg 200 mg · CMC 0,020 mg 500 mg · CMC 0,026 mg 1g · CMC 0,033 mg 2g · CMC 0,040 mg 5g · CMC 0,053 mg 10 g · CMC 0,06 mg 20 g · CMC 0,08 mg 50 g · CMC 0,10mg 100 g · CMC 0,16 mg 200 g · CMC 0,33 mg 500 g · CMC 0,8 mg 1 kg · CMC 1,6 mg 2 kg · CMC 3 mg 5 kg · CMC 8 mg 10 kg · CMC 16 mg 20 kg · CMC 33 mg Mass (weights and mass standards) |
Internal procedure; At permanent location (S) | PW/L1/11 based on OIML R-111-1:2004 Annex C | |
| 24 | Mass standards of accuracy class F2 Weights of accuracy class F2 |
Calibration — Mass (weights and mass standards) 1 mg · CMC 0,020 mg 2 mg · CMC 0,020 mg 5 mg · CMC 0,020 mg 10 mg · CMC 0,026 mg 20 mg · CMC 0,033 mg 50 mg · CMC 0,040 mg 100 mg · CMC 0,053 mg 200 mg · CMC 0,066 mg 500 mg · CMC 0,083 mg 1g · CMC 0,100 mg 2g · CMC 0,133 mg 5g · CMC 0,166 mg 10 g · CMC 0,200 mg 20 g · CMC 0,26 mg 50 g · CMC 0,33 mg 100 g · CMC 0,53 mg 200 g · CMC 1,0 mg 500 g · CMC 2,6 mg 1 kg · CMC 5,3 mg 2 kg · CMC 10 mg 5 kg · CMC 26 mg 10 kg · CMC 53 mg 20 kg · CMC 100 mg Mass (weights and mass standards) |
Internal procedure; At permanent location (S) | PW/L1/11 based on OIML R-111-1:2004 Annex C | |
| 25 | Mass standards of accuracy class M1 Weights of accuracy class M1 |
Calibration — Mass (weights and mass standards) 1 mg · CMC 0,066 mg 2 mg · CMC 0,066 mg 5 mg · CMC 0,066 mg 10 mg · CMC 0,083 mg 20 mg · CMC 0,10 mg 50 mg · CMC 0,13 mg 100 mg · CMC 0,16 mg 200 mg · CMC 0,20 mg 500 mg · CMC 0,26 mg 1g · CMC 0,33 mg 2g · CMC 0,40 mg 5g · CMC 0,53 mg 10 g · CMC 0,66 mg 20 g · CMC 0,83 mg 50 g · CMC 1,0 mg 100 g · CMC 1,6 mg 200 g · CMC 3 mg 500 g · CMC 8 mg Mass (weights and mass standards) |
Internal procedure; At permanent location (S) | PW/L1/11 based on OIML R-111-1:2004 Annex C | |
| 26 | Mass standards of accuracy class M1 Weights of accuracy class M1 |
Calibration — Mass (weights and mass standards) 1 kg · CMC 16 mg 2 kg · CMC 33 mg 5 kg · CMC 83 mg 10 kg · CMC 166 mg 20 kg · CMC 333 mg Mass (weights and mass standards) |
Internal procedure; At permanent location (S) | PW/L1/11 based on OIML R-111-1:2004 Annex C | |
| 27 | 25 kg mass standards | Calibration — Mass (weights and mass standards) 25 kg · CMC 416 mg Mass (weights and mass standards) |
Internal procedure; At permanent location (S) | PW/L1/11 based on OIML R-111-1:2004 Annex C | |
| 28 | Load weights | Calibration — Mass (weights and mass standards) 1 kg to 30 kg · CMC 1·10⁻⁴ % Mass (weights and mass standards) |
Internal procedure; At permanent location (S) | PW/L1/11 | |
| 29 | Grain density meters 1/4 L | Calibration — Density (solids) 180 g to 220 g · CMC 0,7 g 72 kg/hL to 88 kg/hL · CMC 0,28 kg/hL Density (solids) |
Internal procedure; At permanent location (S) | PW/L1/13 | |
| 30 | Grain density meters 1 L | Calibration — Density (solids) 720 g to 880 g · CMC 2,0 g 72 kg/hL to 88 kg/hL · CMC 0,20 kg/hL Density (solids) |
Internal procedure; At permanent location (S) | PW/L1/13 | |
| 31 | Spectrophotometers | Calibration — Optical density of spectral transmittance optical density of spectral transmittance; spectral range 400 nm to 800 nm — 0,10 to 0,20 · CMC 0,0042 optical density of spectral transmittance; spectral range 400 nm to 800 nm — 0,20 to 0,40 · CMC 0,0045 optical density of spectral transmittance; spectral range 400 nm to 800 nm — 0,40 to 0,66 · CMC 0,0054 optical density of spectral transmittance; spectral range 400 nm to 800 nm — 0,66 to 1,00 · CMC 0,0064 Liquid filters; wavelengths: 235 nm, 257 nm, 313 nm, 350 nm — PDC Blank 0 mg/l: 0,0365 · CMC 0,0044 Liquid filters; wavelengths: 235 nm, 257 nm, 313 nm, 350 nm — PDC Blank 0 mg/l: 0,0387 · CMC 0,0044 Liquid filters; wavelengths: 235 nm, 257 nm, 313 nm, 350 nm — PDC Blank 0 mg/l: 0,0444 · CMC 0,0045 Liquid filters; wavelengths: 235 nm, 257 nm, 313 nm, 350 nm — PDC Blank 0 mg/l: 0,0500 · CMC 0,0045 Liquid filters; wavelengths: 235 nm, 257 nm, 313 nm, 350 nm — PDC 20 mg/l: 0,2482 · CMC 0,0050 Liquid filters; wavelengths: 235 nm, 257 nm, 313 nm, 350 nm — PDC 20 mg/l: 0,1359 · CMC 0,0048 Liquid filters; wavelengths: 235 nm, 257 nm, 313 nm, 350 nm — PDC 20 mg/l: 0,3288 · CMC 0,0052 Liquid filters; wavelengths: 235 nm, 257 nm, 313 nm, 350 nm — PDC 20 mg/l: 0,2963 · CMC 0,0051 Liquid filters; wavelengths: 235 nm, 257 nm, 313 nm, 350 nm — PDC 40 mg/l: 0,4555 · CMC 0,0057 Liquid filters; wavelengths: 235 nm, 257 nm, 313 nm, 350 nm — PDC 40 mg/l: 0,2273 · CMC 0,0053 Liquid filters; wavelengths: 235 nm, 257 nm, 313 nm, 350 nm — PDC 40 mg/l: 0,6082 · CMC 0,0060 Liquid filters; wavelengths: 235 nm, 257 nm, 313 nm, 350 nm — PDC 40 mg/l: 0,5360 · CMC 0,0058 Liquid filters; wavelengths: 235 nm, 257 nm, 313 nm, 350 nm — PDC 60 mg/l: 0,6710 · CMC 0,0064 Liquid filters; wavelengths: 235 nm, 257 nm, 313 nm, 350 nm — PDC 60 mg/l: 0,3245 · CMC 0,0058 Liquid filters; wavelengths: 235 nm, 257 nm, 313 nm, 350 nm — PDC 60 mg/l: 0,8997 · CMC 0,0069 Liquid filters; wavelengths: 235 nm, 257 nm, 313 nm, 350 nm — PDC 60 mg/l: 0,7861 · CMC 0,0067 Liquid filters; wavelengths: 235 nm, 257 nm, 313 nm, 350 nm — PDC 80 mg/l: 0,8852 · CMC 0,0073 Liquid filters; wavelengths: 235 nm, 257 nm, 313 nm, 350 nm — PDC 80 mg/l: 0,4219 · CMC 0,0066 Liquid filters; wavelengths: 235 nm, 257 nm, 313 nm, 350 nm — PDC 80 mg/l: 1,1899 · CMC 0,0079 Liquid filters; wavelengths: 235 nm, 257 nm, 313 nm, 350 nm — PDC 80 mg/l: 1,0366 · CMC 0,0076 Liquid filters; wavelengths: 235 nm, 257 nm, 313 nm, 350 nm — PDC 100 mg/l: 1,0970 · CMC 0,0092 Liquid filters; wavelengths: 235 nm, 257 nm, 313 nm, 350 nm — PDC 100 mg/l: 0,5169 · CMC 0,0083 Liquid filters; wavelengths: 235 nm, 257 nm, 313 nm, 350 nm — PDC 100 mg/l: 1,4815 · CMC 0,0098 Liquid filters; wavelengths: 235 nm, 257 nm, 313 nm, 350 nm — PDC 100 mg/l: 1,2864 · CMC 0,0095 wavelength — 400 nm to 800 nm · CMC 0,18 nm Optical density of spectral transmittance |
Internal procedure; At permanent location (S) and outside of it (P) | PW/L1/10 | |
| 32 | Bourdon tube pressure gauges Electronic pressure gauges - gauge pressure - negative and positive pressure |
Calibration — Pressure -0,1 MPa to 0,1 MPa · CMC 2·10⁻⁵ MPa 0,1 MPa to 0,4 MPa · CMC 1·10⁻⁴ MPa 0,4 MPa to 1 MPa · CMC 2·10⁻⁴ MPa 1 MPa to 2,5 MPa · CMC 6·10⁻⁴ MPa 2,5 MPa to 5 MPa · CMC 1·10⁻³ MPa 5 MPa to 6 MPa · CMC 2·10⁻³ MPa 6 MPa to 10 MPa · CMC 4·10⁻³ MPa 10 MPa to 22 MPa · CMC 1·10⁻² MPa 22 MPa to 50 MPa · CMC 2·10⁻² MPa 50 MPa to 60 MPa · CMC 3·10⁻² MPa Pressure |
Internal procedure; Direct method; At permanent location (S) | PW/L2/01 IW1- PW/L2/01 IW2- PW/L2/01 IW5- PW/L2/01 IW7- PW/L2/01 | |
| 33 | Sound calibrators | Calibration — Sound pressure (sound in air) sound pressure level; re 20 µPa; nominal frequency: 1 kHz — 90 dB to 120 dB · CMC 0,10 dB Sound pressure (sound in air) |
Internal procedure; At permanent location (S) | PW/L3/13 based on PN-EN 60942:2005 | |
| 34 | Sound level meters | Calibration — Sound pressure (sound in air) response of the sound level meter to the sound calibrator signal; re 20 µPa — 90 dB to 130 dB · CMC 0,2 dB Sound pressure (sound in air) |
Internal procedure; At permanent location (S) | PW/L3/14 PW/L3/21 based on PN-EN 60651:2002 PN-EN 60804:2002 PN-EN 61672-1:2005 PN-EN 61672-3:2007 | |
| 35 | Sound level meters | Calibration — Sound pressure (sound in air) response of the sound level meter to electrical test signals; re 20 µPa, frequency range 20 Hz to 20 kHz — 0 dB to 140 dB · CMC 0,2 dB Sound pressure (sound in air) |
Internal procedure; At permanent location (S) | PW/L3/14 PW/L3/21 based on PN-EN 60651:2002 PN-EN 60804:2002 PN-EN 61672-1:2005 PN-EN 61672-3:2007 | |
| 36 | Sound level meters | Calibration — Sound pressure (sound in air) free-field frequency response of the sound level meter; frequency range — 20 Hz to 1 kHz · CMC 0,2 dB free-field frequency response of the sound level meter; frequency range — 2 kHz to 8 kHz · CMC 0,3 dB free-field frequency response of the sound level meter; frequency range — for 16 kHz · CMC 0,5 dB free-field frequency response of the sound level meter; frequency range — for 20 kHz · CMC 0,6 dB Sound pressure (sound in air) |
Internal procedure; At permanent location (S) | PW/L3/14 PW/L3/21 based on PN-EN 60651:2002 PN-EN 60804:2002 | |
| 37 | Sound level meters | Calibration — Sound pressure (sound in air) free-field frequency response of the sound level meter; frequencies — 125 Hz, 1 kHz · CMC 0,2 dB free-field frequency response of the sound level meter; frequencies — 4 kHz, 8 kHz · CMC 0,3 dB Sound pressure (sound in air) |
Internal procedure; At permanent location (S) | PW/L3/14 PW/L3/21 based on PN-EN 61672-1:2005 PN-EN 61672-3:2007 | |
| 38 | Vibration calibrators - vibration acceleration |
Calibration — Vibration acceleration RMS acceleration value; nominal frequency: 15,92 Hz — 1,0 ms⁻² · CMC 1,3 % RMS or peak acceleration value; nominal frequencies: 79,6 Hz, 159,2 Hz — 3,16 ms⁻² · CMC 1,2 % RMS or peak acceleration value; nominal frequencies: 79,6 Hz, 159,2 Hz — 7,07 ms⁻² · CMC 1,2 % RMS or peak acceleration value; nominal frequencies: 79,6 Hz, 159,2 Hz — 10 ms⁻² · CMC 1,2 % Vibration acceleration |
Internal procedure; At permanent location (S) | PW/L3/04 | |
| 39 | pH meters | Calibration — PH pH — 0 to 14 · CMC 0,003 DC voltage — -2300 mV to 2300 mV · CMC 0,2 mV PH |
Internal procedure; Electrical method; At permanent location (S) | PW/L3/10 | |
| 40 | Conductivity meters | Calibration — Specific electrical conductivity (conductometry) specific electrical conductivity — 0,0001 mS/cm to 2 mS/cm · CMC 0,2 % specific electrical conductivity — 2 mS/cm to 500 mS/cm · CMC 0,2 % Specific electrical conductivity (conductometry) |
Internal procedure; Electrical method; At permanent location (S) | PW/L3/11 | |
| 41 | Multimeters Digital voltmeters |
Calibration — DC voltage 0,1 mV to 20 mV · CMC 0,033 % 20 mV to 200 mV · CMC 0,004 % 200 mV to 2 V · CMC 0,00089 % 2 V to 20 V · CMC 0,00039 % 20 V to 200 V · CMC 0,00064 % 200 V to 1000 V · CMC 0,00095 % DC voltage |
Internal procedure; Direct method; At permanent location (S) | PW/L3/07 | |
| 42 | Calibrators | Calibration — DC voltage 10 mV to 200 mV · CMC 0,00075 % 200 mV to 20 V · CMC 0,00046 % 20 V to 200 V · CMC 0,00069 % 200 V to 1000 V · CMC 0,00078 % DC voltage |
Internal procedure; Direct method; At permanent location (S) | PW/L3/05 | |
| 43 | Multimeters Digital ammeters |
Calibration — DC current 10 µA to 200 µA · CMC 0,013 % 0,2 mA to 200 mA · CMC 0,0053 % 0,2 A to 2 A · CMC 0,013 % 2 A to 10 A · CMC 0,043 % DC current |
Internal procedure; Direct method; At permanent location (S) | PW/L3/07 | |
| 44 | Calibrators | Calibration — DC current 10 µA to 200 µA · CMC 0,0093 % 0,2 mA to 2 mA · CMC 0,034 % 2 mA to 20 mA · CMC 0,0036 % 20 mA to 200 mA · CMC 0,0066 % 0,2 A to 2 A · CMC 0,021 % 2 A to 10 A · CMC 0,057 % DC current |
Internal procedure; Direct method; At permanent location (S) | PW/L3/05 | |
| 45 | Multimeters Digital voltmeters |
Calibration — AC voltage 10 Hz — 10 mV to 200 mV · CMC 0,039 % 10 Hz — 0,2 V to 2 V · CMC 0,032 % 10 Hz — 2 V to 20 V · CMC 0,033 % 10 Hz to 40 Hz — 10 mV to 200 mV · CMC 0,021 % 10 Hz to 40 Hz — 0,2 V to 2 V · CMC 0,015 % 10 Hz to 40 Hz — 2 V to 20 V · CMC 0,016 % 40 Hz to 300 Hz — 200 µV to 2 mV · CMC 0,43 % 40 Hz to 300 Hz — 2 mV to 20 mV · CMC 0,052 % 40 Hz to 300 Hz — 20 mV to 200 mV · CMC 0,016 % 40 Hz to 300 Hz — 200 mV to 2 V · CMC 0,009 % 40 Hz to 300 Hz — 2 V to 20 V · CMC 0,0073 % 40 Hz to 300 Hz — 20 V to 200 V · CMC 0,0085 % 40 Hz to 300 Hz — 200 V to 1000 V · CMC 0,019 % 300 Hz to 10 kHz — 200 µV to 2 mV · CMC 0,36 % 300 Hz to 10 kHz — 2 mV to 20 mV · CMC 0,045 % 300 Hz to 10 kHz — 20 mV to 200 mV · CMC 0,014 % 300 Hz to 10 kHz — 200 mV to 2 V · CMC 0,0077 % 300 Hz to 10 kHz — 2 V to 20 V · CMC 0,0055 % 300 Hz to 10 kHz — 20 V to 200 V · CMC 0,0066 % 300 Hz to 10 kHz — 200 V to 1000 V · CMC 0,015 % 10 kHz to 30 kHz — 200 µV to 2 mV · CMC 0,36 % 10 kHz to 30 kHz — 2 mV to 20 mV · CMC 0,046 % 10 kHz to 30 kHz — 20 mV to 200 mV · CMC 0,016 % 10 kHz to 30 kHz — 200 mV to 2 V · CMC 0,0077 % 10 kHz to 30 kHz — 2 V to 20 V · CMC 0,0055 % 10 kHz to 30 kHz — 20 V to 200 V · CMC 0,0084 % 10 kHz to 30 kHz — 200 V to 1000 V · CMC 0,020 % 30 kHz to 100 kHz — 200 µV to 2 mV · CMC 0,45 % 30 kHz to 100 kHz — 2 mV to 20 mV · CMC 0,072 % 30 kHz to 100 kHz — 20 mV to 200 mV · CMC 0,042 % 30 kHz to 100 kHz — 200 mV to 20 V · CMC 0,011 % 30 kHz to 100 kHz — 20 V to 200 V · CMC 0,016 % 30 kHz to 100 kHz — 200 V to 1000 V · CMC 0,026 % 100 kHz to 330 kHz — 200 µV to 2 mV · CMC 0,78 % 100 kHz to 330 kHz — 2 mV to 20 mV · CMC 0,19 % 100 kHz to 330 kHz — 20 mV to 200 mV · CMC 0,13 % 100 kHz to 330 kHz — 200 mV to 2 V · CMC 0,036 % 100 kHz to 330 kHz — 2 V to 20 V · CMC 0,035 % 100 kHz to 330 kHz — 20 V to 200 V · CMC 0,053 % 300 kHz to 1 MHz — 200 µV to 2 mV · CMC 0,0023 · U + 0,024 mV 300 kHz to 1 MHz — 2 mV to 20 mV · CMC 0,4 % 300 kHz to 1 MHz — 20 mV to 200 mV · CMC 0,3 % 300 kHz to 1 MHz — 200 mV to 20 V · CMC 0,2 % AC voltage |
Internal procedure; Direct method; At permanent location (S) | PW/L3/07 | |
| 46 | Calibrators | Calibration — AC voltage for 10 Hz — 20 mV to 200 mV · CMC 0,038 % dla 10 Hz to 40 Hz — 20 mV to 200 mV · CMC 0,021 % 40 Hz to 100 Hz — 10 mV to 200 mV · CMC 0,018 % 40 Hz to 100 Hz — 200 mV to 200 V · CMC 0,011 % 40 Hz to 100 Hz — 200 V to 1000 V · CMC 0,015 % 100 Hz to 2000 Hz — 10 mV to 200 mV · CMC 0,017 % 100 Hz to 2000 Hz — 200 mV to 200 V · CMC 0,01 % 100 Hz to 2000 Hz — 200 V to 1000 V · CMC 0,015 % 2 kHz to 10 kHz — 10 mV to 200 mV · CMC 0,00014 · U + 0,004 mV 2 kHz to 10 kHz — 200 mV to 200 V · CMC 0,012 % 2 kHz to 10 kHz — 200 V to 1000 V · CMC 0,013 % 10 kHz to 30 kHz — 10 mV to 200 mV · CMC 0,00034 · U + 0,008 mV 10 kHz to 30 kHz — 200 mV to 200 V · CMC 0,024 % 10 kHz to 30 kHz — 200 V to 1000 V · CMC 0,026 % 3 kHz to 100 kHz — 20 mV to 200 mV · CMC 0,00077 · U + 0,02 mV 3 kHz to 100 kHz — 200 mV to 200 V · CMC 0,067 % 3 kHz to 100 kHz — 200 V to 1000 V · CMC 0,077 % 100 kHz to 300 kHz — 200 mV to 200 V · CMC 0,4 % 300 kHz to 1 MHz — 200 mV to 200 V · CMC 2,0 % AC voltage |
Internal procedure; Direct method; At permanent location (S) | PW/L3/05 | |
| 47 | Multimeters Digital ammeters |
Calibration — AC current 10 Hz to 1 kHz — 10 µA to 200 µA · CMC 0,026 % 10 Hz to 1 kHz — 0,2 mA to 200 mA · CMC 0,019 % 10 Hz to 1 kHz — 0,2 A to 2 A · CMC 0,042 % 10 Hz to 1 kHz — 2 A to 10 A · CMC 0,061 % 1 kHz to 5 kHz — 10 µA to 200 µA · CMC 0,045 % 1 kHz to 5 kHz — 0,2 mA to 200 mA · CMC 0,030 % 1 kHz to 5 kHz — 0,2 A to 2 A · CMC 0,062 % 1 kHz to 5 kHz — 2 A to 10 A · CMC 0,12 % AC current |
Internal procedure; Direct method; At permanent location (S) | PW/L3/07 | |
| 48 | Calibrators | Calibration — AC current 50 Hz to 2 kHz — 10 µA to 200 µA · CMC 0,061 % 50 Hz to 2 kHz — 0,2 mA to 200 mA · CMC 0,041 % 50 Hz to 2 kHz — 0,2 A to 2 A · CMC 0,073 % 50 Hz to 2 kHz — 2 A to 10 A · CMC 0,1 % 2 kHz to 5 kHz — 10 µA to 200 µA · CMC 0,0003 · I + 0,02 µA 2 kHz to 5 kHz — 0,2 mA to 200 mA · CMC 0,039 % 2 kHz to 5 kHz — 0,2 A to 2 A · CMC 0,083 % 2 kHz to 5 kHz — 2 A to 10 A · CMC 0,26 % AC current |
Internal procedure; Direct method; At permanent location (S) | PW/L3/05 | |
| 49 | Multimeters Digital ohmmeters |
Calibration — DC resistance 0,1 Ω to 1 Ω · CMC 0,014 % 1 Ω to 10 Ω · CMC 0,0030 % 10 Ω to 10 kΩ · CMC 0,0011 % 10 kΩ to 100 kΩ · CMC 0,0014 % 100 kΩ to 1 MΩ · CMC 0,0032 % 1 MΩ to 10 MΩ · CMC 0,0063 % 10 MΩ to 100 MΩ · CMC 0,022 % DC resistance |
Internal procedure; Direct method; At permanent location (S) | PW/L3/07 | |
| 50 | Calibrators | Calibration — DC resistance 1 Ω to 2 Ω · CMC 0,0021 % 2 Ω to 20 Ω · CMC 0,0014 % 20 Ω to 200 kΩ · CMC 0,0011 % 200 kΩ to 2 MΩ · CMC 0,0019 % 2 MΩ to 20 MΩ · CMC 0,0047 % 20 MΩ to 200 MΩ · CMC 0,075 % 100 MΩ · CMC 0,016 % 0,2 GΩ to 1 GΩ · CMC 0,55 % DC resistance |
Internal procedure; Direct method; At permanent location (S) | PW/L3/05 | |
| 51 | Bridges Digital ohmmeters |
Calibration — AC resistance 1 kHz — 1 Ω to 100 kΩ · CMC 0,0003 · R + 2 mΩ AC resistance |
Internal procedure; Direct method; At permanent location (S) | PW/L3/01 | |
| 52 | Variable standard inductors Fixed standard inductors Bridges Inductance meters |
Calibration — Inductance 1 kHz — 1 µH · CMC 5,2 % 1 kHz — 2 µH · CMC 2,5 % 1 kHz — 3 µH · CMC 2,0 % 1 kHz — 5 µH · CMC 1,6 % 1 kHz — 10 µH · CMC 0,52 % 1 kHz — 20 µH · CMC 0,26 % 1 kHz — 30 µH · CMC 0,22 % 1 kHz — 50 µH · CMC 0,17 % 1 kHz — 100 µH · CMC 0,11 % 1 kHz — 200 µH · CMC 0,10 % 1 kHz — 300 µH · CMC 0,08 % 1 kHz — 500 µH · CMC 0,06 % 1 kHz — 1 mH · CMC 0,05 % 1 kHz — 2 mH · CMC 0,05 % 1 kHz — 3 mH · CMC 0,05 % 1 kHz — 5 mH · CMC 0,04 % 1 kHz — 10 mH · CMC 0,04 % 1 kHz — 20 mH · CMC 0,04 % 1 kHz — 30 mH · CMC 0,04 % 1 kHz — 50 mH · CMC 0,04 % 1 kHz — 100 mH · CMC 0,04 % 1 kHz — 200 mH · CMC 0,04 % 1 kHz — 300 mH · CMC 0,04 % 1 kHz — 500 mH · CMC 0,04 % 1 kHz — 1H · CMC 0,04 % 1 kHz — 2H · CMC 0,12 % 1 kHz — 5H · CMC 0,12 % 1 kHz — 10 H · CMC 0,12 % Inductance |
Internal procedure; At permanent location (S) | PW/L3/01 PW/L3/06 | |
| 53 | Variable standard capacitors Fixed standard capacitors Bridges Capacitance meters |
Calibration — Capacitance 1 kHz — 10 pF · CMC 0,007 % 1 kHz — 100 pF · CMC 0,007 % 1 kHz — 500 pF · CMC 0,007 % 1 kHz — 1000 pF · CMC 0,007 % 1 kHz — 5000 pF · CMC 0,007 % 1 kHz — 10000pF · CMC 0,007 % 1 kHz — 0,1 pF to 10 pF · CMC 0,03 % 1 kHz — 10 pF to 0,1 µF · CMC 0,012 % 1 kHz — 0,1 µF to 1 µF · CMC 0,012 % 1 kHz — 1 µF to 10 µF · CMC 0,03 % 1 kHz — 10 µF to 100 µF · CMC 0,05 % Capacitance |
Internal procedure; At permanent location (S) | PW/L3/01 PW/L3/06 | |
| 54 | Period meters (frequency counters-timers) | Calibration — Time (time interval) 0,1 µs to 1 s · CMC (3·10⁻⁵ Hz·T + 1,9·10⁻⁹) T Time (time interval) |
Internal procedure; Direct method; At permanent location (S) | PW/L3/18 | |
| 55 | Quartz generators | Calibration — Frequency 10 Hz to 225 MHz · CMC 3·10⁻⁵ Hz + 1,9·10⁻⁹ f Frequency |
Internal procedure; Direct method; At permanent location (S) | PW/L3/19 | |
| 56 | Digital frequency meters | Calibration — Frequency 1 Hz to 80 MHz · CMC 3·10⁻⁵ Hz + 1,9·10⁻⁹ f Frequency |
Internal procedure; Direct method; At permanent location (S) | PW/L3/18 | |
Reference standards (41)
EURAMET cg-18 v.4.0
IW1- PW/L2/01
IW1-PW/L1/01
IW2- PW/L2/01
IW2-PW/L1/01
IW3-PW/L1/01
IW5- PW/L2/01
IW7- PW/L2/01
OIML R-111-1:2004 Załącznik C
PN-EN 60651:2002
PN-EN 60804:2002
PN-EN 60942:2005
PN-EN 61672-1:2005
PN-EN 61672-3:2007
PN-EN ISO 3650:2000
PN-EN ISO 6508-2:2024-06
PN-EN ISO 7500-1:2018-05
PW/L1/01
PW/L1/02
PW/L1/04
PW/L1/07
PW/L1/10
PW/L1/11
PW/L1/12
PW/L1/13
PW/L1/14
PW/L1/15
PW/L1/16
PW/L2/01
PW/L3/01
PW/L3/04
PW/L3/05
PW/L3/06
PW/L3/07
PW/L3/10
PW/L3/11
PW/L3/13
PW/L3/14
PW/L3/18
PW/L3/19
PW/L3/21