🇵🇱 Przedsiębiorstwo Wdrożeniowe "INMEL" Sp. z o.o. PL
Metrology & calibration
Przedsiębiorstwo Wdrożeniowe "INMEL" Sp. z o.o. is a calibration laboratory accredited by PCA under number AP 076 (Zielona Góra, Poland). Its accreditation scope covers 24 calibration items in the following areas: Metrology & calibration. Calibrated items include: Calibrators, Power quality meters, - type S, R, Analogue ammeters. Most frequently used calibration principles: Internal procedure; Direct method; At permanent location (S), Internal procedure; Indirect electrical method; At permanent locati…, Internal procedure; Direct / indirect method; At permanent location….
At a glance
- Accreditation number: PCA AP 076
- Calibration items in scope: 24
- Types of calibrated items: 27
- Calibration principles used: 4
- City: Zielona Góra, Poland
- Valid until: 07-07-2029
- Accreditation number
- AP 076
- Accreditation body
- PCA
- Address
- ul. Sulechowska 1, 65-022 Zielona Góra
- City
- Zielona Góra, Poland
- Division
- Measurement Laboratory
- Valid until
- 07-07-2029
What this laboratory calibrates (27)
- Calibrators — 8 calibration items
- Power quality meters — 5 calibration items
- - type S, R — 2 calibration items
- Analogue ammeters — 2 calibration items
- Analogue voltmeters — 2 calibration items
- Digital ammeters — 2 calibration items
- Digital voltmeters — 2 calibration items
- Temperature indicators (meters) for thermocouples — 2 calibration items
- Temperature simulators for thermocouples — 2 calibration items
- - except S and R — 1 calibration item
- - except S, R — 1 calibration item
- Analogue frequency meters — 1 calibration item
- Analogue ohmmeters — 1 calibration item
- Analogue phase meters — 1 calibration item
- Digital frequency meters — 1 calibration item
- and 12 more
Calibration principles (4)
- Internal procedure; Direct method; At permanent location (S) — 11 calibration items
- Internal procedure; Indirect electrical method; At permanent location (S) — 6 calibration items
- Internal procedure; Direct / indirect method; At permanent location (S) — 5 calibration items
- Internal procedure; At permanent location (S) — 2 calibration items
Certificate information
- Issue date
- 24.06.2026
- Issue no.
- 23
- Certificate date
- 27.07.2020
- Accreditation cycle
- 18.06.2025 — 07.07.2029
- Approved by
- Katarzyna Wiśniewska
Accreditation scope — calibration items (24)
| No. | Calibrated quantity / subject of calibration | Nominal range / parameters / CMC | Calibration principle | Calibration procedure | |
|---|---|---|---|---|---|
| Calibration items | |||||
| 1 | Calibrators | Calibration — DC voltage 0,0001 mV to 190 mV · CMC 8,8·10⁻⁶ · U + 0,2 μV 0,19 V to 1,9 V · CMC 4,9·10⁻⁶ · U + 1,2 μV 1,9 V to 19 V · CMC 4,2·10⁻⁶ · U + 7,0 μV 19 V to 190 V · CMC 7,8·10⁻⁶ · U + 69 μV 190 V to 1000 V · CMC 8,4·10⁻⁶ · U + 0,64 mV DC voltage |
Internal procedure; Direct method; At permanent location (S) | L-01.00.00 | |
| 2 | Digital voltmeters Analogue voltmeters |
Calibration — DC voltage 0,0001 mV to 190 mV · CMC 8,8·10⁻⁶ · U + 0,2 μV 0,19 V to 1,9 V · CMC 4,9·10⁻⁶ · U + 1,2 μV 1,9 V to 19 V · CMC 4,2·10⁻⁶ · U + 7,0 μV 19 V to 190 V · CMC 7,8·10⁻⁶ · U + 69 μV 190 V to 1000 V · CMC 8,4·10⁻⁶ · U + 0,64 mV DC voltage |
Internal procedure; Direct method; At permanent location (S) | L-04.00.00 based on EURAMET cg-15 v.3.0 | |
| 3 | Calibrators | Calibration — DC current 1 μA to 19 μA · CMC 6,6·10⁻⁵ · I + 0,49 nA 19 μA to 190 μA · CMC 4,3·10⁻⁵ · I + 0,087 nA 0,19 mA to 1,9 mA · CMC 4,3·10⁻⁵ · I + 0,87 nA 1,9 mA to 19 mA · CMC 4,3·10⁻⁵ · I + 8,7 nA 19 mA to 190 mA · CMC 4,4·10⁻⁵ · I + 87 nA 0,19 A to 1,9 A · CMC 5,7·10⁻⁵ · I + 1,3 μA 1,9 A to 8,6 A · CMC 7,4·10⁻⁵ · I + 2,2 μA 8,6 A to 10 A · CMC 7,4·10⁻⁵ · I + 0,4 μA 10 A to 20 A · CMC 7,3·10⁻⁵ · I + 17 μA DC current |
Internal procedure; Direct / indirect method; At permanent location (S) | L-01.00.00 | |
| 4 | Digital ammeters Analogue ammeters |
Calibration — DC current 1 μA to 19 μA · CMC 6,6·10⁻⁵ · I + 0,49 nA 19 μA to 190 μA · CMC 4,3·10⁻⁵ · I + 0,087 nA 0,19 mA to 1,9 mA · CMC 4,3·10⁻⁵ · I + 0,87 nA 1,9 mA to 19 mA · CMC 4,3·10⁻⁵ · I + 8,7 nA 19 mA to 190 mA · CMC 4,4·10⁻⁵ · I + 87 nA 0,19 A to 1,9 A · CMC 5,7·10⁻⁵ · I + 1,3 μA 1,9 A to 8,6 A · CMC 7,4·10⁻⁵ · I + 2,2 μA 8,6 A to 10 A · CMC 7,4·10⁻⁵ · I + 0,4 μA 10 A to 20 A · CMC 7,3·10⁻⁵ · I + 17 μA DC current |
Internal procedure; Direct / indirect method; At permanent location (S) | L-04.00.00 based on EURAMET cg-15 v.3.0 | |
| 5 | Calibrators | Calibration — AC voltage 40 Hz to 100 Hz — 0,3 mV to 190 mV · CMC 1,5·10⁻⁴ · U + 6,2 μV 40 Hz to 100 Hz — 0,19 V to 1,9 V · CMC 1,0·10⁻⁴ · U + 27 μV 40 Hz to 100 Hz — 1,9 V to 19 V · CMC 1·10⁻⁴ · U + 0,26 mV 40 Hz to 100 Hz — 19 V to 190 V · CMC 1,1·10⁻⁴ · U + 2,2 mV 40 Hz to 100 Hz — 190 V to 900 V · CMC 1,7·10⁻⁴ · U + 16 mV 100 Hz to 2 kHz — 0,3 mV to 190 mV · CMC 1,5·10⁻⁴ · U + 4,7 μV 100 Hz to 2 kHz — 0,19 V to 1,9 V · CMC 8,0·10⁻⁵ · U + 26 μV 100 Hz to 2 kHz — 1,9 V to 19 V · CMC 8·10⁻⁵ · U + 0,24 mV 100 Hz to 2 kHz — 19 V to 190 V · CMC 8,5·10⁻⁵ · U + 2,2 mV 100 Hz to 2 kHz — 190 V to 900 V · CMC 1,7·10⁻⁴ · U + 16 mV 2 kHz to 5 kHz — 0,3 mV to 190 mV · CMC 1,5·10⁻⁴ · U + 6,2 μV 2 kHz to 5 kHz — 0,19 V to 1,9 V · CMC 1,0·10⁻⁴ · U + 27 μV 2 kHz to 5 kHz — 1,9 V to 19 V · CMC 1·10⁻⁴ · U + 0,26 mV 2 kHz to 5 kHz — 19 V to 190 V · CMC 1,1·10⁻⁴ · U + 2,2 mV 2 kHz to 5 kHz — 190 V to 900 V · CMC 1,7·10⁻⁴ · U + 16 mV 5 kHz to 10 kHz — 0,3 mV to 190 mV · CMC 1,5·10⁻⁴ · U + 6,2 μV 5 kHz to 10 kHz — 0,19 V to 1,9 V · CMC 1,0·10⁻⁴ · U + 27 μV 5 kHz to 10 kHz — 1,9 V to 19 V · CMC 1·10⁻⁴ · U + 0,26 mV 5 kHz to 10 kHz — 19 V to 190 V · CMC 1,1·10⁻⁴ · U + 2,2 mV 10 kHz to 30 kHz — 0,3 mV to 190 mV · CMC 3,6·10⁻⁴ · U + 11 μV 10 kHz to 30 kHz — 0,19 V to 1,9 V · CMC 2,4·10⁻⁴ · U + 47 μV 10 kHz to 30 kHz — 1,9 V to 19 V · CMC 2,4·10⁻⁴ · U + 0,47 mV 10 kHz to 30 kHz — 19 V to 190 V · CMC 2,4·10⁻⁴ · U + 4,7 mV 30 kHz to 100 kHz — 0,3 mV to 190 mV · CMC 9,4·10⁻⁴ · U + 24 μV 30 kHz to 100 kHz — 0,19 V to 1,9 V · CMC 5,9·10⁻⁴ · U + 0,24 mV 30 kHz to 100 kHz — 1,9 V to 19 V · CMC 5,9·10⁻⁴ · U + 2,4 mV 30 kHz to 100 kHz — 19 V to 190 V · CMC 5,9·10⁻⁴ · U + 24 mV AC voltage |
Internal procedure; Direct method; At permanent location (S) | L-01.00.00 | |
| 6 | Digital voltmeters Analogue voltmeters Power quality meters |
Calibration — AC voltage 40 Hz to 100 Hz — 0,3 mV to 190 mV · CMC 1,5·10⁻⁴ · U + 6,2 μV 40 Hz to 100 Hz — 0,19 V to 1,9 V · CMC 1,0·10⁻⁴ · U + 27 μV 40 Hz to 100 Hz — 1,9 V to 19 V · CMC 1·10⁻⁴ · U + 0,26 mV 40 Hz to 100 Hz — 19 V to 190 V · CMC 1,1·10⁻⁴ · U + 2,2 mV 40 Hz to 100 Hz — 190 V to 900 V · CMC 1,7·10⁻⁴ · U + 16 mV 100 Hz to 2 kHz — 0,3 mV to 190 mV · CMC 1,5·10⁻⁴ · U + 4,7 μV 100 Hz to 2 kHz — 0,19 V to 1,9 V · CMC 8,0·10⁻⁵ · U + 26 μV 100 Hz to 2 kHz — 1,9 V to 19 V · CMC 8·10⁻⁵ · U + 0,24 mV 100 Hz to 2 kHz — 19 V to 190 V · CMC 8,5·10⁻⁵ · U + 2,2 mV 100 Hz to 2 kHz — 190 V to 900 V · CMC 1,7·10⁻⁴ · U + 16 mV 2 kHz to 5 kHz — 0,3 mV to 190 mV · CMC 1,5·10⁻⁴ · U + 6,2 μV 2 kHz to 5 kHz — 0,19 V to 1,9 V · CMC 1,0·10⁻⁴ · U + 27 μV 2 kHz to 5 kHz — 1,9 V to 19 V · CMC 1·10⁻⁴ · U + 0,26 mV 2 kHz to 5 kHz — 19 V to 190 V · CMC 1,1·10⁻⁴ · U + 2,2 mV 2 kHz to 5 kHz — 190 V to 900 V · CMC 1,7·10⁻⁴ · U + 16 mV 5 kHz to 10 kHz — 0,3 mV to 190 mV · CMC 1,5·10⁻⁴ · U + 6,2 μV 5 kHz to 10 kHz — 0,19 V to 1,9 V · CMC 1,0·10⁻⁴ · U + 27 μV 5 kHz to 10 kHz — 1,9 V to 19 V · CMC 1·10⁻⁴ · U + 0,26 mV 5 kHz to 10 kHz — 19 V to 190 V · CMC 1,1·10⁻⁴ · U + 2,2 mV 10 kHz to 30 kHz — 0,3 mV to 190 mV · CMC 3,6·10⁻⁴ · U + 11 μV 10 kHz to 30 kHz — 0,19 V to 1,9 V · CMC 2,4·10⁻⁴ · U + 47 μV 10 kHz to 30 kHz — 1,9 V to 19 V · CMC 2,4·10⁻⁴ · U + 0,47 mV 10 kHz to 30 kHz — 19 V to 190 V · CMC 2,4·10⁻⁴ · U + 4,7 mV 30 kHz to 100 kHz — 0,3 mV to 190 mV · CMC 9,4·10⁻⁴ · U + 24 μV 30 kHz to 100 kHz — 0,19 V to 1,9 V · CMC 5,9·10⁻⁴ · U + 0,24 mV 30 kHz to 100 kHz — 1,9 V to 19 V · CMC 5,9·10⁻⁴ · U + 2,4 mV 30 kHz to 100 kHz — 19 V to 190 V · CMC 5,9·10⁻⁴ · U + 24 mV AC voltage |
Internal procedure; Direct method; At permanent location (S) | L-04.00.00 based on EURAMET cg-15 v.3.0 | |
| 7 | Calibrators | Calibration — AC current 40 Hz to 5 kHz — 10 μA to 190 μA · CMC 3,2·10⁻⁴ · I + 30 nA 40 Hz to 5 kHz — 0,19 mA to 1,9 mA · CMC 3,2·10⁻⁴ · I + 0,24 μA 40 Hz to 5 kHz — 1,9 mA to 19 mA · CMC 3,2·10⁻⁴ · I + 2,4 μA 40 Hz to 5 kHz — 19 mA to 200 mA · CMC 3,2·10⁻⁴ · I + 24 μA 40 Hz to 60 Hz — 200 mA to 2 A · CMC 3,6·10⁻⁴ · I + 84 μA 40 Hz to 60 Hz — 2 A to 8,6 A · CMC 3,7·10⁻⁴ · I + 0,23 mA 40 Hz to 60 Hz — 8,6 A to 10 A · CMC 3,5·10⁻⁴ · I + 0,71 mA 40 Hz to 60 Hz — 10 A to 20 A · CMC 4,2·10⁻⁴ · I + 1,1 mA 40 Hz to 60 Hz — 20 A to 50 A · CMC 4,8·10⁻⁴ · I + 1,5 mA AC current |
Internal procedure; Direct / indirect method; At permanent location (S) | L-01.00.00 | |
| 8 | Digital ammeters Analogue ammeters Power quality meters |
Calibration — AC current 40 Hz to 5 kHz — 10 μA to 190 μA · CMC 3,2·10⁻⁴ · I + 30 nA 40 Hz to 5 kHz — 0,19 mA to 1,9 mA · CMC 3,2·10⁻⁴ · I + 0,24 μA 40 Hz to 5 kHz — 1,9 mA to 19 mA · CMC 3,2·10⁻⁴ · I + 2,4 μA 40 Hz to 5 kHz — 19 mA to 200 mA · CMC 3,2·10⁻⁴ · I + 24 μA 40 Hz to 60 Hz — 200 mA to 2 A · CMC 3,6·10⁻⁴ · I + 84 μA 40 Hz to 60 Hz — 2 A to 8,6 A · CMC 3,7·10⁻⁴ · I + 0,23 mA 40 Hz to 60 Hz — 8,6 A to 10 A · CMC 3,5·10⁻⁴ · I + 0,71 mA 40 Hz to 60 Hz — 10 A to 20 A · CMC 4,2·10⁻⁴ · I + 1,1 mA 40 Hz to 60 Hz — 20 A to 50 A · CMC 4,8·10⁻⁴ · I + 1,5 mA AC current |
Internal procedure; Direct / indirect method; At permanent location (S) | L-04.00.00 based on EURAMET cg-15 v.3.0 | |
| 9 | Shunts Resistance calibrators Fixed resistors Variable resistors |
Calibration — DC resistance 1 mΩ to 10 mΩ · CMC 6,7·10⁻⁵ · R + 5,7 nΩ 10 mΩ to 100 mΩ · CMC 5,3·10⁻⁵ · R + 69 nΩ 0,1 Ω to 1 Ω · CMC 4,5·10⁻⁵ · R + 0,81 µΩ 1 Ω to 19 Ω · CMC 2,3·10⁻⁵ · R + 68 µΩ 19 Ω to 190 Ω · CMC 1,3·10⁻⁵ · R + 0,17 mΩ 0,19 kΩ to 1,9 kΩ · CMC 1,0·10⁻⁵ · R + 1,5 mΩ 1,9 kΩ to 19 kΩ · CMC 1,0·10⁻⁵ · R + 15 mΩ 19 kΩ to 190 kΩ · CMC 1.2·10⁻⁵ · R + 75 mΩ 0,19 MΩ to 1,9 MΩ · CMC 2,0·10⁻⁵ · R + 1,1 Ω 1,9 MΩ to 19 MΩ · CMC 0,0046 % 19 MΩ to 100 MΩ · CMC 2,4·10⁻⁴ · R + 11 kΩ DC resistance |
Internal procedure; Direct / indirect method; At permanent location (S) | L-01.00.00 | |
| 10 | Digital ohmmeters Analogue ohmmeters |
Calibration — DC resistance 1 mΩ to 10 mΩ · CMC 6,7·10⁻⁵ · R + 5,7 nΩ 10 mΩ to 100 mΩ · CMC 5,3·10⁻⁵ · R + 69 nΩ 0,1 Ω to 1 Ω · CMC 4,5·10⁻⁵ · R + 0,81 µΩ 1 Ω to 19 Ω · CMC 2,3·10⁻⁵ · R + 68 µΩ 19 Ω to 190 Ω · CMC 1,3·10⁻⁵ · R + 0,17 mΩ 0,19 kΩ to 1,9 kΩ · CMC 1,0·10⁻⁵ · R + 1,5 mΩ 1,9 kΩ to 19 kΩ · CMC 1,0·10⁻⁵ · R + 15 mΩ 19 kΩ to 190 kΩ · CMC 1.2·10⁻⁵ · R + 75 mΩ 0,19 MΩ to 1,9 MΩ · CMC 2,0·10⁻⁵ · R + 1,1 Ω 1,9 MΩ to 19 MΩ · CMC 0,0046 % 19 MΩ to 100 MΩ · CMC 2,4·10⁻⁴ · R + 11 kΩ DC resistance |
Internal procedure; Direct method; At permanent location (S) | L-04.00.00 based on EURAMET cg-15 v.3 | |
| 11 | Calibrators | Calibration — Phase angle 50 Hz — 0 ° to 360 ° · CMC 0,062 ° Phase angle |
Internal procedure; Direct method; At permanent location (S) | L-02.00.00 | |
| 12 | Digital phase meters Analogue phase meters |
Calibration — Phase angle 50 Hz — 0 ° to 360 ° · CMC 0,062 ° Phase angle |
Internal procedure; Direct method; At permanent location (S) | L-04.00.00 | |
| 13 | Power quality meters | Calibration — Phase angle 50 Hz — 0 ° to 360 ° · CMC 0,11 ° Phase angle |
Internal procedure; Direct method; At permanent location (S) | L-04.00.00 | |
| 14 | Calibrators | Calibration — AC power 50 Hz; P (cos φ=1); Q (sin φ=1); I (0,1 to 50) A; U (50 V to 750) V; single-phase: 5 W to 37,5 kW; 5 Var to 37,5 kVar · CMC 0,043 % 50 Hz; P (cos φ=1); Q (sin φ=1); I (0,1 to 50) A; U (50 V to 750) V; three-phase: 15 W to 112,5 kW; 15 kVar to 112,5 kVar · CMC 0,043 % AC power |
Internal procedure; At permanent location (S) | L-02.00.00 | |
| 15 | Single-phase analogue active power meters Single-phase digital active power meters Single-phase digital reactive power meters Three-phase digital reactive power meters Power quality meters |
Calibration — AC power 50 Hz; P (cos φ=1); Q (sin φ=1); I (0,1 to 50) A; U (50 V to 750) V; single-phase: 5 W to 37,5 kW; 5 Var to 37,5 kVar · CMC 0,043 % 50 Hz; P (cos φ=1); Q (sin φ=1); I (0,1 to 50) A; U (50 V to 750) V; three-phase: 15 W to 112,5 kW; 15 kVar to 112,5 kVar · CMC 0,043 % AC power |
Internal procedure; At permanent location (S) | L-04.00.00 | |
| 16 | Temperature simulators for thermocouples - type S, R |
Calibration — Electrical simulation of quantities -50 °C to 1700 °C · CMC 0,1 °C Electrical simulation of quantities |
Internal procedure; Indirect electrical method; At permanent location (S) | L-03.00.00 based on EURAMET cg-11 v.2.0, PN-EN 60584-1: 2014 | |
| 17 | Temperature simulators for thermocouples - except S and R |
Calibration — Electrical simulation of quantities -200 °C to 1700 °C · CMC 0,05 °C Electrical simulation of quantities |
Internal procedure; Indirect electrical method; At permanent location (S) | L-03.00.00 based on EURAMET cg-11 v.2.0, PN-EN 60584-1: 2014 | |
| 18 | Temperature simulators for resistance sensors | Calibration — Electrical simulation of quantities -200 °C to 800 °C · CMC 0,05 °C Electrical simulation of quantities |
Internal procedure; Indirect electrical method; At permanent location (S) | L-03.00.00 based on EURAMET cg-11 v.2.0, PN-EN 60751: 2022-11 | |
| 19 | Temperature indicators (meters) for thermocouples - type S, R |
Calibration — Electrical simulation of quantities -50 °C to 1700 °C · CMC 0,1 °C Electrical simulation of quantities |
Internal procedure; Indirect electrical method; At permanent location (S) | L-04.00.00 based on EURAMET cg-11 v.2.0, PN-EN 60584-1:2014 | |
| 20 | Temperature indicators (meters) for thermocouples - except S, R |
Calibration — Electrical simulation of quantities -200 °C to 1700 °C · CMC 0,05 °C Electrical simulation of quantities |
Internal procedure; Indirect electrical method; At permanent location (S) | L-04.00.00 based on EURAMET cg-11 v.2.0, PN-EN 60584-1:2014 | |
| 21 | Temperature indicators (meters) for resistance sensors | Calibration — Electrical simulation of quantities -200 °C to 800 °C · CMC 0,05 °C Electrical simulation of quantities |
Internal procedure; Indirect electrical method; At permanent location (S) | L-04.00.00 based on EURAMET cg-11 v.2.0, PN-EN 60751: 2022-11 | |
| 22 | Calibrators | Calibration — Time (time interval) 1 to 9999,9999 s · CMC 0,00043 % Time (time interval) |
Internal procedure; Direct method; At permanent location (S) | L-02.00.00 | |
| 23 | Calibrators | Calibration — Frequency 20 Hz to 100 kHz · CMC 0,00043 % Frequency |
Internal procedure; Direct method; At permanent location (S) | L-01.00.00 L-02.00.00 | |
| 24 | Analogue frequency meters Digital frequency meters Power quality meters |
Calibration — Frequency 20 Hz to 100 kHz · CMC 0,00043 % Frequency |
Internal procedure; Direct method; At permanent location (S) | L-04.00.00 | |
Reference standards (10)
EURAMET cg-11 v.2.0
EURAMET cg-15 v.3
EURAMET cg-15 v.3.0
L-01.00.00
L-02.00.00
L-03.00.00
L-04.00.00
PN-EN 60584-1: 2014
PN-EN 60584-1:2014
PN-EN 60751: 2022-11