🇵🇱 Przedsiębiorstwo Wdrożeniowe "INMEL" Sp. z o.o. PL

PCA AP 076 • Zielona Góra, Poland • 24 calibration items

Metrology & calibration

Przedsiębiorstwo Wdrożeniowe "INMEL" Sp. z o.o. is a calibration laboratory accredited by PCA under number AP 076 (Zielona Góra, Poland). Its accreditation scope covers 24 calibration items in the following areas: Metrology & calibration. Calibrated items include: Calibrators, Power quality meters, - type S, R, Analogue ammeters. Most frequently used calibration principles: Internal procedure; Direct method; At permanent location (S), Internal procedure; Indirect electrical method; At permanent locati…, Internal procedure; Direct / indirect method; At permanent location….

At a glance

  • Accreditation number: PCA AP 076
  • Calibration items in scope: 24
  • Types of calibrated items: 27
  • Calibration principles used: 4
  • City: Zielona Góra, Poland
  • Valid until: 07-07-2029
Accreditation number
AP 076
Accreditation body
PCA
Address
ul. Sulechowska 1, 65-022 Zielona Góra
City
Zielona Góra, Poland
Division
Measurement Laboratory
Valid until
07-07-2029

What this laboratory calibrates (27)

Calibration principles (4)

Certificate information

Issue date
24.06.2026
Issue no.
23
Certificate date
27.07.2020
Accreditation cycle
18.06.2025 — 07.07.2029
Approved by
Katarzyna Wiśniewska

Accreditation scope — calibration items (24)

The uncertainty covered by the CMC is the expanded uncertainty with a coverage probability of approximately 95 % and is expressed in measurand units. A CMC uncertainty value expressed as a percentage is the relative measurement uncertainty and refers to the percentage of the value of the measurand.

No. Calibrated quantity / subject of calibration Nominal range / parameters / CMC Calibration principle Calibration procedure
Calibration items
1 Calibrators Calibration — DC voltage
0,0001 mV to 190 mV · CMC 8,8·10⁻⁶ · U + 0,2 μV 0,19 V to 1,9 V · CMC 4,9·10⁻⁶ · U + 1,2 μV 1,9 V to 19 V · CMC 4,2·10⁻⁶ · U + 7,0 μV 19 V to 190 V · CMC 7,8·10⁻⁶ · U + 69 μV 190 V to 1000 V · CMC 8,4·10⁻⁶ · U + 0,64 mV
DC voltage
Internal procedure; Direct method; At permanent location (S) L-01.00.00
2 Digital voltmeters
Analogue voltmeters
Calibration — DC voltage
0,0001 mV to 190 mV · CMC 8,8·10⁻⁶ · U + 0,2 μV 0,19 V to 1,9 V · CMC 4,9·10⁻⁶ · U + 1,2 μV 1,9 V to 19 V · CMC 4,2·10⁻⁶ · U + 7,0 μV 19 V to 190 V · CMC 7,8·10⁻⁶ · U + 69 μV 190 V to 1000 V · CMC 8,4·10⁻⁶ · U + 0,64 mV
DC voltage
Internal procedure; Direct method; At permanent location (S) L-04.00.00 based on EURAMET cg-15 v.3.0
3 Calibrators Calibration — DC current
1 μA to 19 μA · CMC 6,6·10⁻⁵ · I + 0,49 nA 19 μA to 190 μA · CMC 4,3·10⁻⁵ · I + 0,087 nA 0,19 mA to 1,9 mA · CMC 4,3·10⁻⁵ · I + 0,87 nA 1,9 mA to 19 mA · CMC 4,3·10⁻⁵ · I + 8,7 nA 19 mA to 190 mA · CMC 4,4·10⁻⁵ · I + 87 nA 0,19 A to 1,9 A · CMC 5,7·10⁻⁵ · I + 1,3 μA 1,9 A to 8,6 A · CMC 7,4·10⁻⁵ · I + 2,2 μA 8,6 A to 10 A · CMC 7,4·10⁻⁵ · I + 0,4 μA 10 A to 20 A · CMC 7,3·10⁻⁵ · I + 17 μA
DC current
Internal procedure; Direct / indirect method; At permanent location (S) L-01.00.00
4 Digital ammeters
Analogue ammeters
Calibration — DC current
1 μA to 19 μA · CMC 6,6·10⁻⁵ · I + 0,49 nA 19 μA to 190 μA · CMC 4,3·10⁻⁵ · I + 0,087 nA 0,19 mA to 1,9 mA · CMC 4,3·10⁻⁵ · I + 0,87 nA 1,9 mA to 19 mA · CMC 4,3·10⁻⁵ · I + 8,7 nA 19 mA to 190 mA · CMC 4,4·10⁻⁵ · I + 87 nA 0,19 A to 1,9 A · CMC 5,7·10⁻⁵ · I + 1,3 μA 1,9 A to 8,6 A · CMC 7,4·10⁻⁵ · I + 2,2 μA 8,6 A to 10 A · CMC 7,4·10⁻⁵ · I + 0,4 μA 10 A to 20 A · CMC 7,3·10⁻⁵ · I + 17 μA
DC current
Internal procedure; Direct / indirect method; At permanent location (S) L-04.00.00 based on EURAMET cg-15 v.3.0
5 Calibrators Calibration — AC voltage
40 Hz to 100 Hz — 0,3 mV to 190 mV · CMC 1,5·10⁻⁴ · U + 6,2 μV 40 Hz to 100 Hz — 0,19 V to 1,9 V · CMC 1,0·10⁻⁴ · U + 27 μV 40 Hz to 100 Hz — 1,9 V to 19 V · CMC 1·10⁻⁴ · U + 0,26 mV 40 Hz to 100 Hz — 19 V to 190 V · CMC 1,1·10⁻⁴ · U + 2,2 mV 40 Hz to 100 Hz — 190 V to 900 V · CMC 1,7·10⁻⁴ · U + 16 mV 100 Hz to 2 kHz — 0,3 mV to 190 mV · CMC 1,5·10⁻⁴ · U + 4,7 μV 100 Hz to 2 kHz — 0,19 V to 1,9 V · CMC 8,0·10⁻⁵ · U + 26 μV 100 Hz to 2 kHz — 1,9 V to 19 V · CMC 8·10⁻⁵ · U + 0,24 mV 100 Hz to 2 kHz — 19 V to 190 V · CMC 8,5·10⁻⁵ · U + 2,2 mV 100 Hz to 2 kHz — 190 V to 900 V · CMC 1,7·10⁻⁴ · U + 16 mV 2 kHz to 5 kHz — 0,3 mV to 190 mV · CMC 1,5·10⁻⁴ · U + 6,2 μV 2 kHz to 5 kHz — 0,19 V to 1,9 V · CMC 1,0·10⁻⁴ · U + 27 μV 2 kHz to 5 kHz — 1,9 V to 19 V · CMC 1·10⁻⁴ · U + 0,26 mV 2 kHz to 5 kHz — 19 V to 190 V · CMC 1,1·10⁻⁴ · U + 2,2 mV 2 kHz to 5 kHz — 190 V to 900 V · CMC 1,7·10⁻⁴ · U + 16 mV 5 kHz to 10 kHz — 0,3 mV to 190 mV · CMC 1,5·10⁻⁴ · U + 6,2 μV 5 kHz to 10 kHz — 0,19 V to 1,9 V · CMC 1,0·10⁻⁴ · U + 27 μV 5 kHz to 10 kHz — 1,9 V to 19 V · CMC 1·10⁻⁴ · U + 0,26 mV 5 kHz to 10 kHz — 19 V to 190 V · CMC 1,1·10⁻⁴ · U + 2,2 mV 10 kHz to 30 kHz — 0,3 mV to 190 mV · CMC 3,6·10⁻⁴ · U + 11 μV 10 kHz to 30 kHz — 0,19 V to 1,9 V · CMC 2,4·10⁻⁴ · U + 47 μV 10 kHz to 30 kHz — 1,9 V to 19 V · CMC 2,4·10⁻⁴ · U + 0,47 mV 10 kHz to 30 kHz — 19 V to 190 V · CMC 2,4·10⁻⁴ · U + 4,7 mV 30 kHz to 100 kHz — 0,3 mV to 190 mV · CMC 9,4·10⁻⁴ · U + 24 μV 30 kHz to 100 kHz — 0,19 V to 1,9 V · CMC 5,9·10⁻⁴ · U + 0,24 mV 30 kHz to 100 kHz — 1,9 V to 19 V · CMC 5,9·10⁻⁴ · U + 2,4 mV 30 kHz to 100 kHz — 19 V to 190 V · CMC 5,9·10⁻⁴ · U + 24 mV
AC voltage
Internal procedure; Direct method; At permanent location (S) L-01.00.00
6 Digital voltmeters
Analogue voltmeters
Power quality meters
Calibration — AC voltage
40 Hz to 100 Hz — 0,3 mV to 190 mV · CMC 1,5·10⁻⁴ · U + 6,2 μV 40 Hz to 100 Hz — 0,19 V to 1,9 V · CMC 1,0·10⁻⁴ · U + 27 μV 40 Hz to 100 Hz — 1,9 V to 19 V · CMC 1·10⁻⁴ · U + 0,26 mV 40 Hz to 100 Hz — 19 V to 190 V · CMC 1,1·10⁻⁴ · U + 2,2 mV 40 Hz to 100 Hz — 190 V to 900 V · CMC 1,7·10⁻⁴ · U + 16 mV 100 Hz to 2 kHz — 0,3 mV to 190 mV · CMC 1,5·10⁻⁴ · U + 4,7 μV 100 Hz to 2 kHz — 0,19 V to 1,9 V · CMC 8,0·10⁻⁵ · U + 26 μV 100 Hz to 2 kHz — 1,9 V to 19 V · CMC 8·10⁻⁵ · U + 0,24 mV 100 Hz to 2 kHz — 19 V to 190 V · CMC 8,5·10⁻⁵ · U + 2,2 mV 100 Hz to 2 kHz — 190 V to 900 V · CMC 1,7·10⁻⁴ · U + 16 mV 2 kHz to 5 kHz — 0,3 mV to 190 mV · CMC 1,5·10⁻⁴ · U + 6,2 μV 2 kHz to 5 kHz — 0,19 V to 1,9 V · CMC 1,0·10⁻⁴ · U + 27 μV 2 kHz to 5 kHz — 1,9 V to 19 V · CMC 1·10⁻⁴ · U + 0,26 mV 2 kHz to 5 kHz — 19 V to 190 V · CMC 1,1·10⁻⁴ · U + 2,2 mV 2 kHz to 5 kHz — 190 V to 900 V · CMC 1,7·10⁻⁴ · U + 16 mV 5 kHz to 10 kHz — 0,3 mV to 190 mV · CMC 1,5·10⁻⁴ · U + 6,2 μV 5 kHz to 10 kHz — 0,19 V to 1,9 V · CMC 1,0·10⁻⁴ · U + 27 μV 5 kHz to 10 kHz — 1,9 V to 19 V · CMC 1·10⁻⁴ · U + 0,26 mV 5 kHz to 10 kHz — 19 V to 190 V · CMC 1,1·10⁻⁴ · U + 2,2 mV 10 kHz to 30 kHz — 0,3 mV to 190 mV · CMC 3,6·10⁻⁴ · U + 11 μV 10 kHz to 30 kHz — 0,19 V to 1,9 V · CMC 2,4·10⁻⁴ · U + 47 μV 10 kHz to 30 kHz — 1,9 V to 19 V · CMC 2,4·10⁻⁴ · U + 0,47 mV 10 kHz to 30 kHz — 19 V to 190 V · CMC 2,4·10⁻⁴ · U + 4,7 mV 30 kHz to 100 kHz — 0,3 mV to 190 mV · CMC 9,4·10⁻⁴ · U + 24 μV 30 kHz to 100 kHz — 0,19 V to 1,9 V · CMC 5,9·10⁻⁴ · U + 0,24 mV 30 kHz to 100 kHz — 1,9 V to 19 V · CMC 5,9·10⁻⁴ · U + 2,4 mV 30 kHz to 100 kHz — 19 V to 190 V · CMC 5,9·10⁻⁴ · U + 24 mV
AC voltage
Internal procedure; Direct method; At permanent location (S) L-04.00.00 based on EURAMET cg-15 v.3.0
7 Calibrators Calibration — AC current
40 Hz to 5 kHz — 10 μA to 190 μA · CMC 3,2·10⁻⁴ · I + 30 nA 40 Hz to 5 kHz — 0,19 mA to 1,9 mA · CMC 3,2·10⁻⁴ · I + 0,24 μA 40 Hz to 5 kHz — 1,9 mA to 19 mA · CMC 3,2·10⁻⁴ · I + 2,4 μA 40 Hz to 5 kHz — 19 mA to 200 mA · CMC 3,2·10⁻⁴ · I + 24 μA 40 Hz to 60 Hz — 200 mA to 2 A · CMC 3,6·10⁻⁴ · I + 84 μA 40 Hz to 60 Hz — 2 A to 8,6 A · CMC 3,7·10⁻⁴ · I + 0,23 mA 40 Hz to 60 Hz — 8,6 A to 10 A · CMC 3,5·10⁻⁴ · I + 0,71 mA 40 Hz to 60 Hz — 10 A to 20 A · CMC 4,2·10⁻⁴ · I + 1,1 mA 40 Hz to 60 Hz — 20 A to 50 A · CMC 4,8·10⁻⁴ · I + 1,5 mA
AC current
Internal procedure; Direct / indirect method; At permanent location (S) L-01.00.00
8 Digital ammeters
Analogue ammeters
Power quality meters
Calibration — AC current
40 Hz to 5 kHz — 10 μA to 190 μA · CMC 3,2·10⁻⁴ · I + 30 nA 40 Hz to 5 kHz — 0,19 mA to 1,9 mA · CMC 3,2·10⁻⁴ · I + 0,24 μA 40 Hz to 5 kHz — 1,9 mA to 19 mA · CMC 3,2·10⁻⁴ · I + 2,4 μA 40 Hz to 5 kHz — 19 mA to 200 mA · CMC 3,2·10⁻⁴ · I + 24 μA 40 Hz to 60 Hz — 200 mA to 2 A · CMC 3,6·10⁻⁴ · I + 84 μA 40 Hz to 60 Hz — 2 A to 8,6 A · CMC 3,7·10⁻⁴ · I + 0,23 mA 40 Hz to 60 Hz — 8,6 A to 10 A · CMC 3,5·10⁻⁴ · I + 0,71 mA 40 Hz to 60 Hz — 10 A to 20 A · CMC 4,2·10⁻⁴ · I + 1,1 mA 40 Hz to 60 Hz — 20 A to 50 A · CMC 4,8·10⁻⁴ · I + 1,5 mA
AC current
Internal procedure; Direct / indirect method; At permanent location (S) L-04.00.00 based on EURAMET cg-15 v.3.0
9 Shunts
Resistance calibrators
Fixed resistors
Variable resistors
Calibration — DC resistance
1 mΩ to 10 mΩ · CMC 6,7·10⁻⁵ · R + 5,7 nΩ 10 mΩ to 100 mΩ · CMC 5,3·10⁻⁵ · R + 69 nΩ 0,1 Ω to 1 Ω · CMC 4,5·10⁻⁵ · R + 0,81 µΩ 1 Ω to 19 Ω · CMC 2,3·10⁻⁵ · R + 68 µΩ 19 Ω to 190 Ω · CMC 1,3·10⁻⁵ · R + 0,17 mΩ 0,19 kΩ to 1,9 kΩ · CMC 1,0·10⁻⁵ · R + 1,5 mΩ 1,9 kΩ to 19 kΩ · CMC 1,0·10⁻⁵ · R + 15 mΩ 19 kΩ to 190 kΩ · CMC 1.2·10⁻⁵ · R + 75 mΩ 0,19 MΩ to 1,9 MΩ · CMC 2,0·10⁻⁵ · R + 1,1 Ω 1,9 MΩ to 19 MΩ · CMC 0,0046 % 19 MΩ to 100 MΩ · CMC 2,4·10⁻⁴ · R + 11 kΩ
DC resistance
Internal procedure; Direct / indirect method; At permanent location (S) L-01.00.00
10 Digital ohmmeters
Analogue ohmmeters
Calibration — DC resistance
1 mΩ to 10 mΩ · CMC 6,7·10⁻⁵ · R + 5,7 nΩ 10 mΩ to 100 mΩ · CMC 5,3·10⁻⁵ · R + 69 nΩ 0,1 Ω to 1 Ω · CMC 4,5·10⁻⁵ · R + 0,81 µΩ 1 Ω to 19 Ω · CMC 2,3·10⁻⁵ · R + 68 µΩ 19 Ω to 190 Ω · CMC 1,3·10⁻⁵ · R + 0,17 mΩ 0,19 kΩ to 1,9 kΩ · CMC 1,0·10⁻⁵ · R + 1,5 mΩ 1,9 kΩ to 19 kΩ · CMC 1,0·10⁻⁵ · R + 15 mΩ 19 kΩ to 190 kΩ · CMC 1.2·10⁻⁵ · R + 75 mΩ 0,19 MΩ to 1,9 MΩ · CMC 2,0·10⁻⁵ · R + 1,1 Ω 1,9 MΩ to 19 MΩ · CMC 0,0046 % 19 MΩ to 100 MΩ · CMC 2,4·10⁻⁴ · R + 11 kΩ
DC resistance
Internal procedure; Direct method; At permanent location (S) L-04.00.00 based on EURAMET cg-15 v.3
11 Calibrators Calibration — Phase angle
50 Hz — 0 ° to 360 ° · CMC 0,062 °
Phase angle
Internal procedure; Direct method; At permanent location (S) L-02.00.00
12 Digital phase meters
Analogue phase meters
Calibration — Phase angle
50 Hz — 0 ° to 360 ° · CMC 0,062 °
Phase angle
Internal procedure; Direct method; At permanent location (S) L-04.00.00
13 Power quality meters Calibration — Phase angle
50 Hz — 0 ° to 360 ° · CMC 0,11 °
Phase angle
Internal procedure; Direct method; At permanent location (S) L-04.00.00
14 Calibrators Calibration — AC power
50 Hz; P (cos φ=1); Q (sin φ=1); I (0,1 to 50) A; U (50 V to 750) V; single-phase: 5 W to 37,5 kW; 5 Var to 37,5 kVar · CMC 0,043 % 50 Hz; P (cos φ=1); Q (sin φ=1); I (0,1 to 50) A; U (50 V to 750) V; three-phase: 15 W to 112,5 kW; 15 kVar to 112,5 kVar · CMC 0,043 %
AC power
Internal procedure; At permanent location (S) L-02.00.00
15 Single-phase analogue active power meters
Single-phase digital active power meters
Single-phase digital reactive power meters
Three-phase digital reactive power meters
Power quality meters
Calibration — AC power
50 Hz; P (cos φ=1); Q (sin φ=1); I (0,1 to 50) A; U (50 V to 750) V; single-phase: 5 W to 37,5 kW; 5 Var to 37,5 kVar · CMC 0,043 % 50 Hz; P (cos φ=1); Q (sin φ=1); I (0,1 to 50) A; U (50 V to 750) V; three-phase: 15 W to 112,5 kW; 15 kVar to 112,5 kVar · CMC 0,043 %
AC power
Internal procedure; At permanent location (S) L-04.00.00
16 Temperature simulators for thermocouples
- type S, R
Calibration — Electrical simulation of quantities
-50 °C to 1700 °C · CMC 0,1 °C
Electrical simulation of quantities
Internal procedure; Indirect electrical method; At permanent location (S) L-03.00.00 based on EURAMET cg-11 v.2.0, PN-EN 60584-1: 2014
17 Temperature simulators for thermocouples
- except S and R
Calibration — Electrical simulation of quantities
-200 °C to 1700 °C · CMC 0,05 °C
Electrical simulation of quantities
Internal procedure; Indirect electrical method; At permanent location (S) L-03.00.00 based on EURAMET cg-11 v.2.0, PN-EN 60584-1: 2014
18 Temperature simulators for resistance sensors Calibration — Electrical simulation of quantities
-200 °C to 800 °C · CMC 0,05 °C
Electrical simulation of quantities
Internal procedure; Indirect electrical method; At permanent location (S) L-03.00.00 based on EURAMET cg-11 v.2.0, PN-EN 60751: 2022-11
19 Temperature indicators (meters) for thermocouples
- type S, R
Calibration — Electrical simulation of quantities
-50 °C to 1700 °C · CMC 0,1 °C
Electrical simulation of quantities
Internal procedure; Indirect electrical method; At permanent location (S) L-04.00.00 based on EURAMET cg-11 v.2.0, PN-EN 60584-1:2014
20 Temperature indicators (meters) for thermocouples
- except S, R
Calibration — Electrical simulation of quantities
-200 °C to 1700 °C · CMC 0,05 °C
Electrical simulation of quantities
Internal procedure; Indirect electrical method; At permanent location (S) L-04.00.00 based on EURAMET cg-11 v.2.0, PN-EN 60584-1:2014
21 Temperature indicators (meters) for resistance sensors Calibration — Electrical simulation of quantities
-200 °C to 800 °C · CMC 0,05 °C
Electrical simulation of quantities
Internal procedure; Indirect electrical method; At permanent location (S) L-04.00.00 based on EURAMET cg-11 v.2.0, PN-EN 60751: 2022-11
22 Calibrators Calibration — Time (time interval)
1 to 9999,9999 s · CMC 0,00043 %
Time (time interval)
Internal procedure; Direct method; At permanent location (S) L-02.00.00
23 Calibrators Calibration — Frequency
20 Hz to 100 kHz · CMC 0,00043 %
Frequency
Internal procedure; Direct method; At permanent location (S) L-01.00.00 L-02.00.00
24 Analogue frequency meters
Digital frequency meters
Power quality meters
Calibration — Frequency
20 Hz to 100 kHz · CMC 0,00043 %
Frequency
Internal procedure; Direct method; At permanent location (S) L-04.00.00

Reference standards (10)

EURAMET cg-11 v.2.0
EURAMET cg-15 v.3
EURAMET cg-15 v.3.0
L-01.00.00
L-02.00.00
L-03.00.00
L-04.00.00
PN-EN 60584-1: 2014
PN-EN 60584-1:2014
PN-EN 60751: 2022-11

The same scope as data (JSON): https://labcoda.pl/api/accreditation-scopes/labs/PL/AP%20076